400 Series High-Temperature Duct Smoke Detector: F I R E

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

H V A C S y s t e m s M o n i t o r i n g

400 Series™
High-Temperature
Duct Smoke Detector
Models Available
DH400ACDCIHT 4-wire ionization high-temperature duct
smoke detector

Product Overview

System Sensor DH400ACDCIHT is designed for interior duct to provide dependable performance for management
or exterior duct applications where extreme temperatures of fans, blowers, and air conditioning systems. The twist-in,
can exceed standard detector capabilities. (For exterior twist-out 1451DHHT High-Temperature ionization detec-
applications use DH400 OE-1 outdoor enclosure.) The tor head allows easy removal for quick cleaning, mainte-
DH400ACDCIHT samples air currents passing through a nance, and replacement without removing the duct housing.

Temperature range 32° – 158°F (0° – 70°C) Agency Listings

Air velocity rating from 500 – 4,000 FPM DH400ACDCIHT UL S911


APA451 UL S4011
24 VAC/DC or 120/220 VAC operation RTS451KEY UL S2522
RTS451 UL S2522
Easy and quick mounting to round or rectangular RA400Z UL S2522
ducts from 1′ – 12′ (0.3 – 3.7 meters) wide PA400W UL S3593

3-year warranty

Accessories
System Sensor provides system flexibility with a variety of As with our duct detectors, all duct detector accessories are
accessories, including two remote test stations, and several UL listed.
different means of visible and audible system annunciation.

ALARM POWER
ALARM
F ALARM

I
R
ON
RESET TEST

E RESET

APA451 RTS451KEY PA400W with RTS451 RA400Z


Piezo Remote Test PS24LOW Add-on Strobe Remote Test Remote
Annunciator Station with Key Station Annunciator
Architect/Engineer Specifications
The air duct smoke detector shall be a System Sensor ing using the RTS451KEY or RTS451 Remote Test Station.
Model DH400ACDCIHT Series Duct Smoke Detector. The duct detector housing shall incorporate an airtight
The detector shall be UL listed per UL S911, standard smoke chamber in compliance with UL S911. The housing
for Smoke Detectors for Duct Applications, specifically shall be capable of mounting to rectangular or round ducts
for use in air handling systems. The detector shall oper- up to 12′ wide without adapter brackets. An integral filter
ate at air velocities from 500 feet per minute to 4000 system shall be included to reduce dust and residue effects
feet per minute. The detector shall have an operating on detector and housing, thereby reducing maintenance
temperature range of 32˚F to 158˚F. The detector housing and servicing. Sampling tubes shall be installed after the
shall be equipped with an integral mounting base capable housing is mounted to the duct by passing through the duct
of accommodating ionization detector heads. It shall be housing. Terminal connections shall be of the strip and
capable of local testing via magnetic switch or remote test- clamp method suitable for 14–18 AWG wiring.
Electrical Specifications

Power Supply Voltage 20 - 29 VDC 24 VAC 50 - 60 Hz 120 VAC 50 - 60 Hz 220/240 VAC 50 - 60 Hz

CURRENT REQUIREMENTS (USING NO ACCESSORIES)


Max. standby current 25 mA 35 mA RMS 20 mA RMS 20 mA RMS
Max. alarm current 95 mA 55 mA RMS 55 mA RMS 30 mA RMS

CONTACT RATINGS Accessory Current Loads at 24 VDC


Alarm initiation contacts (SPST) 2.0A @ 30 VAC/DC (0.6 power factor) Device Standby Alarm
Alarm auxiliar y contacts (DPDT) 10A @ 30 VDC AP451 12mA max. 30mA max.
10A @ 250 VAC PA400W 0mA max. 15mA max.
Trouble contacts (SPST) 0.3 @32 VDC (resistive) RA400Z 0mA max. 7mA max.
*NOTE: When initiating an alarm, the RTS451 and RTS451KEY require 103mA in alarm. Nominal standby RTS451 0mA max.* 8mA max.
current is 0mA. Alarm current is 8 mA maximum when test magnet is removed.
RTS451KEY 12mA max.* 8mA max.
NOTE: Accessories are only rated to 120°F and must be installed indoors.

ANY COMBINATION OF ACCESSORIES MAY BE USED SUCH THAT THE


GIVEN CURRENT LOADS TOTAL:

100mA OR LESS IN THE STANDBY STATE,


150mA OR LESS IN THE ALARM STATE.
Physical Specifications
Length: Weight: Air Duct Velocity:
14.5 inches (36.8 cm) 4.5 lbs. (2.0 kg) 500 to 4000 ft./min.

Width: Operating Temperature Range: Operating Humidity Range:


5 inches (12.7 cm) 32º to 158ºF (0º to 70ºC) 10% to 93% relative humidity

Depth: Storage Temperature Range: Voltage:


4 inches (10.2 cm) –22º to 158ºF (–30º to 70ºC) 24 VAC/VDC or 120/220 VAC

Ordering Information
Model Description
DH400ACDCIHT 4-wire ionization high-temperature duct RTS451KEY Remote test station with key
smoke detector RTS451 Remote test station
1451DHHT Replacement ionization high-temperature PA400W Piezo sounder (white)
sensor head PS24LOW Add-on strobe (white)
ST-1.5 Metal sampling tube duct widths 1′–2′ RA400Z Remote annunciator alarm LED
ST-3 Metal sampling tube duct widths 2′–4′ CRT400 Ion cover removal tool
ST-5 Metal sampling tube duct widths 4′–8′ F36-05-00 Replacement air filters (two per package)
ST-10 Metal sampling tube duct widths 8′–12′ MOD400R Sensitivity test module
P48-21-00 End cap for metal sampling tubes M02-04-00 Test magnet
APA451 Annunciator with piezo alarm and power LEDs RS14 Ion replacement screen
DH400OE-1 Weatherproof Outdoor Enclosure A2650-01 Replacement installation kit (mounting hardware)

System Sensor Sales and Service


System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor – Far East System Sensor – India
3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700
St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118
Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor – Australia System Sensor – Russia
Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982
www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983

­© 2003 System Sensor. The company reserves the right to change product specifications without notice. A05-0953-002•10/03•#1169

You might also like