ARL-500 UCM Test Instructions For Gearless Machines - en
ARL-500 UCM Test Instructions For Gearless Machines - en
ARL-500 UCM Test Instructions For Gearless Machines - en
1.1. Relevant staff should take necessary measures for the safety of the passengers as well as himself of all
transactions at risk.
- Prevent the elevator run by someone else,
- Be sure that there is nobody in the elevator hoist way,
- Be sure that all elevator doors are closed
1.2. When power is switched on at door zone, ARL-500 controller does not activate door bridging function
after one correct travel. After a travel, controller checks ML1-ML2 zone enable signals. If there is no fault and
no short circuit at ML1-ML2 door zone signals then door bridging is activated.
1.3. With the firmware version V20R134 or later, a test function for UCM safety valve is provided in ARL-500
menu. This test function shall be used during the test operation.
1.3.1. To be able to use the UCM test function, the door pre-opening option shall be enabled as shown
below:
- Go to “Debug tools” screen by pressing the up button while the ARL-500 is in the main screen
- Set “UCM Test” parameter. It has 3 options:
This setting is not stored in the memory. After the power is switched off or “Reset system !” is activated, it
turns to “Off”.
1.3.3. When the UCM test function is set to “Fast (V3)”, ARL-500 does the followings:
1.3.4. The UCM test shall be done with doors closed for safety purposes. But in order to simulate an open
door, the door safety circuit needs to be interrupted manually after door circuits are bridged (after UCM test
function is enabled). To do this, remove the wire from terminal 130 on the KBK-9 board to open the door
safety circuit.
1.3.5. In case of UCM, ARL-500 gives “UCM detected” error. The lift is kept out of service, even if the main
power is switched off and on. To reset this error:
- Go to “Debug tools” screen by pressing the up button while the ARL-500 is in the main screen
- Activate “Reset system !” option
- the empty car in up direction in the upper part of the well (from top-1 to top floor) and
- the fully loaded car in down direction in the lower part of the well (from bottom+1 floor to bottom
floor) to simulate the worst case load.
2. UCM test procedure (with door bridging option)
d) Remove the wire from terminal 130 on the KBK-9 board (see 1.3.4)
e) Press the up direction button on the emergency electrical operation hand terminal. Drive
accelerates to pre-defined speed in up direction (see 1.3.3)
f) After leaving the door zone, because door bridging is interrupted, the power of the machine brakes
is also cut off. An emergency stop (UCM fall) occurs. ARL-500 gives “UCM detected” error.
g) Measure the stopping distance. Test is successful if the stopping distance is lower than the limit
value.
d) Remove the wire from terminal 130 on the KBK-9 board (see 1.3.4)
e) Press the down direction button on the emergency electrical operation hand terminal. Drive
accelerates to pre-defined speed in down direction (see 1.3.3)
f) After leaving the door zone, because door bridging is interrupted, the power of the machine brakes
is also cut off. An emergency stop (UCM fall) occurs. ARL-500 gives “UCM detected” error.
g) Measure the stopping distance. Test is successful if the stopping distance is lower than the limit
value.