Operating 2-floor lifts with ARL-500 with encoder counter system

Step 1: Mount an additional door zone magnet between two floors (approximately in the middle)

Door zone magnet


for 2nd floor

Additional door zone


magnet between two
floors (in the middle)

Door zone magnet


ML2 for 1st floor
ML1

CAR

Step 2: Make the following settings in ARL-500 menu:

 System settings --> Position sensing: Encoder


 System settings --> Number of floors: 3
 Door settings --> Door type settings --> Individual settings for floors
A
Floor-1: Auto
Floor-2: None
Floor-3: Auto
 Display settings --> Floor texts --> Floor 3: Write the same floor text written for Floor 2
 Encoder Settings --> Travel distances --> Slowing distance in high speed: The distance of 817 and 818
signals. The parameter “1.8-SLOWING DST.” in ADrive should be set 15cm lower than this value
 Encoder Settings --> Travel distances --> Stopping distance in low speed: To the same value with the
parameter “1.9-STOPING DST.” in ADrive
 Encoder Settings --> Hardware configuration --> Flag length: The length of the door zone magnet
 Exit menu and select “Yes” to save parameters
 Encoder settings --> Learn shaft
 Elevator makes a learning run. After it finishes, exit menu and select “Yes” to save parameters
 If the elevator control cabinet includes an automatic rescue (evacuation) function, then dismount the
additional door zone magnet between two floors after learning run is finished.

Step 3: Adjust the number of floor setting of the LOP placed on the 2nd floor as 3 instead of 2 (by menu or
dipswitches).

Step 4: Connect the car push button connector of the 2nd floor to the socket labeled as 3 instead of 2 on the
KABKON in the COP.