Control Valves Positioner
Control Valves Positioner
Control Valves Positioner
HiFlo
HiFlo
Valve Features
Corrosion-resistant
Easy calibration
cover and base
Interchangable
Valve positioners are primarily utilized by Mascot. A • Easily Field Reversed – A reversal of action in the field is
pneumatic module for air control signals, or an electro- achieved by simply turning the cam over, reversing the
pneumatic (I/P) module for milliamp electrical control signals anti-backlash spring and changing the output tubing.
is offered with Mascot valve positioner. Valve positioners are • Insensitive to Mounting Position – Positioners can
single or double-acting, force-balanced instruments that be mounted in any orientation.
provide fast, sensitive and accurate positioning of cylinder
• Simple Calibration – Easy calibration as there is minimal
and diaphragm actuators. These positioners being compact,
interaction between zero and span. For protection and to
field reversible, are designed for high performance and are
discourage tampering, positioner adjustments are totally
reliable because of the rugged built.
enclosed.
Features
• Split-Range Service – Standard signal ranges are 4
• P/P or I/P Signal Convertible – Easy accomplishment of
- 20 mA for the electro-pneumatic (I/P) module and 3-
field conversion from one control signal to another by
15 psi (0-1 Bar) for the pneumatic (P/P) model. Optional
replacing one module with another
ranges are 10-50 mA and 6-30 psi (0.4-2.1 Bar),
• Corrosion Resistant – Epoxy powder painted on cover and respectively. All models can be calibrated for a 2 or 3-
base assembly and continuously purged from the inside with way split range.
instrument air making corrosion resistant internal section.
• Simplified Maintenance – Ease in maintenance because
Internal working parts are constructed from 300 series
of positioners simplicity, modular design and a few parts.
stainless steel, anodized aluminum or Buna-N.
• Regulator not needed – Designed to withstand 150 psi
• Shock and Vibration Resistant – the make and design of
(10.3 bar) at all parts, the valve positioners are insensitive to
valve positioners is such that they have high natural frequency
supply pressure fluctuations.
coupled with pneumatic damping. It is unaffected by
vibration, acceleration up to 2 G’s, and frequencies to 500 • Low Air Consumption – Steady state air consumption is
Hz. .25 SCFM @ 60 psi (4.1 Bar) supply.
• For Single or Double-acting Actuators – The valve • Changeable Flow Characteristics – Easily changed
positioner is versatile usable with either single or double cam provides characterized flow feedback.
acting actuators. • High Air Flow Gain Model – Standard on 200 square
• Standard Mounting – Valve positioners use the standard inch actuators and above, optional on others.
mounting. By changing the cams and follower arms, the same • Output Gauge Helps Monitor Unit: – Permits easy
positioner can be used on both linear and rotary actuators. verification of transducer and positioner calibration as it
This results in fewer required spare parts. indicates transducer output to the positioner.
2
HiFlo
Specifications & performance
* Data is based on tests of the HiFlo positioner mounted on a double-acting cylinder actuator having a piston area of 25 square inches with
a valve stroke of 1.5 inches (38mm) and 60 psi (401 Bar) supply pressure instrument. single was 3-15 psi (0-1 Bar) with pneumatic module
3
HiFlo
Operation
Figure 4 shows a valve positioner . The valve positioner is a the instrument signal capsule and balance beam
force-balanced instrument, with pneumatic module installed downward. This motion of the balance beam also pulls
on a double-acting actuator for air to open action. the pilot valve spool downward from its equilibrium
Positioning is based on a balance of two forces; one position. This opens the pilot valve ports, supplying
proportional to the instrument signal and the other air to port 1 and exhausting air from port 2. This causes
proportional to the stem position. the actuator piston upward.
A downward force is activated as the signal pressure acts Proportionally to the valve position, to counter the force
upon the diaphragms in the instrument signal capsule, generated by the instrument signal capsule, the piston
through the follower arm and cam, the motion of the continues to stroke upwards until force in the feedback spring
actuator stem is transmitted to the top end of the feedback increases sufficiently. At this point the balance beam and
spring resulting in the varying of tension in feedback spring spool begin to return to equilibrium position. As the valve
as stem position changes. spool ports start to close, the air flow rate to the actuator is
decreased.
The system will be in equilibrium and stem will be in the
position called for by the instrument signal when these The feedback spring tension force will equal the force
opposing forces balance exactly. The balance will move up generated in the instrument signal capsule after the piston
or down and by means of the spool valve, will change the has reached the required position. The balance beam and
output pressures and flow rate if these opposing forces are instrument signal capsule will remain in their
not in balance. This will lead to the piston to moving until the equilibrium positions with no air flowing to the actuator
tension on the feedback spring opposes exactly the until a change in the instrument signal is made.
instrument signal pressure. A proportional downward movement of the actuator piston
The detailed sequence of positioner operations are as and stem is affected by a decrease in the instrument signal
follows: An increase in the instrument signal forces which reverses the described actions.
Output 2
Cylinder
Piston
Output 1 Range Adjustment Gear
Zero
Adjust- Follower Arm
ment
R
Take-off Arm
L-
Lock
Knob
Feedback Spring
Balance
MODULE Beam
Signal
3-15 psi
Instrument Signal Capsule
4
HiFlo
Mounting with different models/make
Optional Models
Extended Temperature : Built with Flurosilicone
diaphragms and O-rings
for temperatures -
50°F to 250°F
Oxygen Service : Built with Flurosilicone diaphragms
and O-rings cleaned and
assembled in a clean room.
Piped Vent : To vent off positioner exhaust used
for natural gas operations.
5
HiFlo
Mounting dimensions
5 6 7 8
5.23
.5-1 1.0 2. 2.5 3 3.5 4
Pin Assembly
No. 19564
(0.5 to 4 inch stroke) # 62684
3.92
.5-1 1.5 2 2.5 3
TOP VIEW
(0.5 to 3 inch stroke) # 52684
0.5*
45° Thru
8.00 Optional feedback spring 5.35
.5-1
Inch required in positioner .5-1 1.5 2 2.5 3 3.5 4
1.5 22.5° Stroke. for 1/2 inch stroke.
2
2.5 (0.5 to 4 inch adjusstable stroke)
65TYP 3
3.5
5.42
SIDE VIEW
2.13
Output 2
Output 2
5.08
1.62 Output
.80 Dia
Instrument
Vent
Screen
2.01
1.62 1.00 Instrument
.39
Instrument
.75 Supply
.12
.25
1.79 3.87
Supply Optional 1/2 N.P.T. for piped exhaust or
4.50
conduit for position indicator
BACK VIEW
FRONT VIEW
6
HiFlo
Mounting Dimensions
.188 Dia.
Pin
Pin in lever
Rotates 90°
TOP VIEW with Valve
90° Valve
45° Positioner Rotation
45° Rotation
90°
22.5°
Z
2.913 3.625
71414 61824
Valve rotation on
Increasing signal
X = 2.30 to 2.73 X = 2.30 to 3.45
.67 Zo
4.469
NOTE 1
Z 81414
2.13
Output 2
Output 2
5.08
1.62 .80 Dia Output
Vent
Instrument
Screen
2.01
1.62 1.00 Instrument
.39
.75 Supply
Instrument
.12
.25
1.79 3.87
Supply Optional 1/2 N.P.T. for piped 4.50
exhaust or conduit for position
indicator BACK VIEW
7
HiFlo
Ordering Information