Control Valves Positioner

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Control Valves Positioner

HiFlo
HiFlo
Valve Features

Corrosion-resistant
Easy calibration
cover and base

Withstands 150 psi


Two -sided cam
at all parts
for easy field
reversibility

Optional / NPT for


piped exhaust

Split ranges can be


easily adjusted

Electro-pneumatic (I/P) module Pneumatic module

Interchangable

Valve positioners are primarily utilized by Mascot. A • Easily Field Reversed – A reversal of action in the field is
pneumatic module for air control signals, or an electro- achieved by simply turning the cam over, reversing the
pneumatic (I/P) module for milliamp electrical control signals anti-backlash spring and changing the output tubing.
is offered with Mascot valve positioner. Valve positioners are • Insensitive to Mounting Position – Positioners can
single or double-acting, force-balanced instruments that be mounted in any orientation.
provide fast, sensitive and accurate positioning of cylinder
• Simple Calibration – Easy calibration as there is minimal
and diaphragm actuators. These positioners being compact,
interaction between zero and span. For protection and to
field reversible, are designed for high performance and are
discourage tampering, positioner adjustments are totally
reliable because of the rugged built.
enclosed.
Features
• Split-Range Service – Standard signal ranges are 4
• P/P or I/P Signal Convertible – Easy accomplishment of
- 20 mA for the electro-pneumatic (I/P) module and 3-
field conversion from one control signal to another by
15 psi (0-1 Bar) for the pneumatic (P/P) model. Optional
replacing one module with another
ranges are 10-50 mA and 6-30 psi (0.4-2.1 Bar),
• Corrosion Resistant – Epoxy powder painted on cover and respectively. All models can be calibrated for a 2 or 3-
base assembly and continuously purged from the inside with way split range.
instrument air making corrosion resistant internal section.
• Simplified Maintenance – Ease in maintenance because
Internal working parts are constructed from 300 series
of positioners simplicity, modular design and a few parts.
stainless steel, anodized aluminum or Buna-N.
• Regulator not needed – Designed to withstand 150 psi
• Shock and Vibration Resistant – the make and design of
(10.3 bar) at all parts, the valve positioners are insensitive to
valve positioners is such that they have high natural frequency
supply pressure fluctuations.
coupled with pneumatic damping. It is unaffected by
vibration, acceleration up to 2 G’s, and frequencies to 500 • Low Air Consumption – Steady state air consumption is
Hz. .25 SCFM @ 60 psi (4.1 Bar) supply.
• For Single or Double-acting Actuators – The valve • Changeable Flow Characteristics – Easily changed
positioner is versatile usable with either single or double cam provides characterized flow feedback.
acting actuators. • High Air Flow Gain Model – Standard on 200 square
• Standard Mounting – Valve positioners use the standard inch actuators and above, optional on others.
mounting. By changing the cams and follower arms, the same • Output Gauge Helps Monitor Unit: – Permits easy
positioner can be used on both linear and rotary actuators. verification of transducer and positioner calibration as it
This results in fewer required spare parts. indicates transducer output to the positioner.

2
HiFlo
Specifications & performance

HiFlo Positioner Specifications


Specification Pneumatic Module
Input signal range: 3-1 5 psi (0-1 Bar), 2 or 3-way split range;
6-30 (0.4-2.1 Bar) psi, 2 or 3 and 4-way
Supply pressure 30 psi to 150 psi (2.1 to 10.3 Bar)
Ambient Standard model: -20° to +1 85° F
temperature limits (-30° to 85° C) Ext. temp, model:
-50° to +250° F (-46° to 1 21 ° C)
Connections Supply, instrument and output: 1 U -inch
NPT; Gauges: 1 /e-inch NPT
Standard materials Stainless steel, anodized aluminum,
nickel-plated steel, epoxy powder-painted
steel and Buna-N
Net weight 3lbs. (1.4kg)

HiFlo Positioner Performance*


HiFlo Positioner Performance Pneumatic Module
Independent Linearity - Maximum deviation from a best fit straight line ±1.0% F.S.
Hysteresis - Maximum position error for the same value of input when 0.5% F.S.
approached from opposite ends of the scale.
Repeatability - Maximum variation in position for the same value of input when 0.2% F.S.
approached from the same direction.
Response Level - Maximum change in input required to cause a change in 0.2% F.S.
valve stem position in one direction.
Dead Band - Maximum change in input required to cause a reversal in valve 0.3% F.S.
stem movement.
Resolution - Smallest possible change in valve stem position. .1%F.S.
Steady State Air Consumption @ 60 psi (4.1 Bar) .25 SCFM
Supply Pressure Effect - Position change for a 10 psi (0.7 Bar) supply pressure change. .05% F.S.

"Open-loop" Gain - Ratio of cylinder pressure unbalance to instrument 300:1


pressure change with locked stem. @60 psi
Maximum Flow Capacity @ 60 psi (4.1 Bar) 1 1 SCFM
Frequency Response - -6 dB Frequency .8 Hz -
(With sinusoidal input of ±5% F.S. centered about 50% F.S.) Phase Angle at -6dB - 71°
Stroking Speed - Closed to open 2.3 in/sec.
-Open to closed 1 .3 in/sec.

* Data is based on tests of the HiFlo positioner mounted on a double-acting cylinder actuator having a piston area of 25 square inches with
a valve stroke of 1.5 inches (38mm) and 60 psi (401 Bar) supply pressure instrument. single was 3-15 psi (0-1 Bar) with pneumatic module

3
HiFlo
Operation

Figure 4 shows a valve positioner . The valve positioner is a the instrument signal capsule and balance beam
force-balanced instrument, with pneumatic module installed downward. This motion of the balance beam also pulls
on a double-acting actuator for air to open action. the pilot valve spool downward from its equilibrium
Positioning is based on a balance of two forces; one position. This opens the pilot valve ports, supplying
proportional to the instrument signal and the other air to port 1 and exhausting air from port 2. This causes
proportional to the stem position. the actuator piston upward.
A downward force is activated as the signal pressure acts Proportionally to the valve position, to counter the force
upon the diaphragms in the instrument signal capsule, generated by the instrument signal capsule, the piston
through the follower arm and cam, the motion of the continues to stroke upwards until force in the feedback spring
actuator stem is transmitted to the top end of the feedback increases sufficiently. At this point the balance beam and
spring resulting in the varying of tension in feedback spring spool begin to return to equilibrium position. As the valve
as stem position changes. spool ports start to close, the air flow rate to the actuator is
decreased.
The system will be in equilibrium and stem will be in the
position called for by the instrument signal when these The feedback spring tension force will equal the force
opposing forces balance exactly. The balance will move up generated in the instrument signal capsule after the piston
or down and by means of the spool valve, will change the has reached the required position. The balance beam and
output pressures and flow rate if these opposing forces are instrument signal capsule will remain in their
not in balance. This will lead to the piston to moving until the equilibrium positions with no air flowing to the actuator
tension on the feedback spring opposes exactly the until a change in the instrument signal is made.
instrument signal pressure. A proportional downward movement of the actuator piston
The detailed sequence of positioner operations are as and stem is affected by a decrease in the instrument signal
follows: An increase in the instrument signal forces which reverses the described actions.

Figure 4 : Positioner Schematic for Air-to-Open (Retract)

Output 2

Cylinder
Piston
Output 1 Range Adjustment Gear

Range Adjustment Lock Screw


Zero Adjustment Knob
Pivot

Zero
Adjust- Follower Arm
ment
R

Take-off Arm
L-

Lock
Knob
Feedback Spring
Balance
MODULE Beam
Signal
3-15 psi
Instrument Signal Capsule

Pilot Valve Body Pilot Valve Spool

4
HiFlo
Mounting with different models/make

The uniqueness and principal feature of the HiFlo positioner


is that it can be mounted on any pneumatic actuator, both
single and double acting. Diagrams presented herewith show
the mounting dimensions and standard follower arms that are
available.

HiFlo Positioner comes standard on a Mascot GFlo


HiFlo mounts easily on a diaphragm actuator.

Optional Models
Extended Temperature : Built with Flurosilicone
diaphragms and O-rings
for temperatures -
50°F to 250°F
Oxygen Service : Built with Flurosilicone diaphragms
and O-rings cleaned and
assembled in a clean room.
Piped Vent : To vent off positioner exhaust used
for natural gas operations.

The HiFlo positioner is designed to mount on most rotary valves

5
HiFlo
Mounting dimensions

Linear Stroke Actuators


10.45

5 6 7 8

(5 to 8 inch stroke) # 72684

5.23
.5-1 1.0 2. 2.5 3 3.5 4
Pin Assembly
No. 19564
(0.5 to 4 inch stroke) # 62684

3.92
.5-1 1.5 2 2.5 3
TOP VIEW
(0.5 to 3 inch stroke) # 52684

Pin attached to follower arm and


3.63 rotates the arm 45° resting on a flat Valve Stem 1.96
surface which travels with valve stroke. .5-1 1.5

(0.5 to 1.5 inch stroke) # 42684


.67

0.5*
45° Thru
8.00 Optional feedback spring 5.35
.5-1
Inch required in positioner .5-1 1.5 2 2.5 3 3.5 4
1.5 22.5° Stroke. for 1/2 inch stroke.
2
2.5 (0.5 to 4 inch adjusstable stroke)
65TYP 3
3.5

Standard Arms Available


1.31
For linear Mounting

5.42
SIDE VIEW

1.97 3.200 Dia'


Mounting Holes
.39
2.36 3.91 for #10 Screws
.39

2.13
Output 2

Output 2
5.08

1.62 Output
.80 Dia
Instrument

Vent
Screen
2.01
1.62 1.00 Instrument
.39
Instrument

.75 Supply
.12
.25
1.79 3.87
Supply Optional 1/2 N.P.T. for piped exhaust or
4.50
conduit for position indicator
BACK VIEW
FRONT VIEW
6
HiFlo
Mounting Dimensions

.188 Dia.
Pin
Pin in lever
Rotates 90°
TOP VIEW with Valve

NOTE : Dimension X and Y (Radius


Typical Rotary Mounting
of pin from valve stem Centerline)
are a function of Z0- Z0 and solve
3.63 for X and Y, using the following
equations: X
.20 Y
NOTE 1 Z = Z0 + .670X = .765 X Z
Y 14
Y = .414 X ZEach follower arm 814
X 1
TE
NO will work with particular range for X 45° 90°
Values.

90° Valve
45° Positioner Rotation
45° Rotation
90°
22.5°
Z

2.913 3.625

71414 61824
Valve rotation on
Increasing signal
X = 2.30 to 2.73 X = 2.30 to 3.45
.67 Zo
4.469
NOTE 1
Z 81414

SIDE VIEW X = 2.30 to 4.29


Standard Arms Available For Rotary Mounting

1.97 3.200 Dia'


Mounting Holes
.39
for #10 Screws
2.36 3.91
.39

2.13
Output 2

Output 2
5.08
1.62 .80 Dia Output
Vent
Instrument

Screen
2.01
1.62 1.00 Instrument
.39

.75 Supply
Instrument

.12
.25
1.79 3.87
Supply Optional 1/2 N.P.T. for piped 4.50
exhaust or conduit for position
indicator BACK VIEW
7
HiFlo
Ordering Information

Ordering Information MODELS


We need the following information when you order the HiFlo HiFlo Extended Temperature
positioner. This helps you get accurate material and timely HiFlo Oxygen Service, HiFlo Piped Vent
delivery thereby leading to great satisfaction of serving you in 90° TURN ROTARY ACTUATORS
the best possible way. You are requested to specify the When ordering a positioner for a pneumatic rotary actuator,
desired part numbers. you should select two part numbers; one from section 3
LINEAR ACTUATOR which provides part numbers for each positioner model, and
When ordering a positioner for a pneumatic linear actuator, another from section 4 which includes part numbers for the
you should choose two part numbers; one from Section 1 follower arm.
which provides positioner part numbers for each model, and
another from Section 2 which contains follower arm part SECTION 3 - Pneumatic Positioner
numbers. Model with 3-15 psi span *
Installed HiFlo HiFlo HiFlo HiFlo
SECTION 1: Pneumatic Positioner Cam **** Ext. Oxy. Piped
Model with 3-15 psi Span* 25, 50 B 46584 66584 82684 03684
H Series H Series H Series H Series and100 C 56584 76584 92684 86584
Ext. Oxy. Piped sq. in Act.
Temp. Ser. Vent
Std. Air-to-Open** 89934 70764 31684 51684 * Can be split ranged 2:1 or 3:1without additional parts. Also
available are positioner models with 6.30 psi span and the same
Stroke Air-to-Close 99934 80764 41684 64644 split ranges.
Short Air-to-Open 61684 81684 02684 22684
Stroke Air-to-Close 71684 91684 12684 32684 **** The cam can be turned over in the field to the opposite side "B"
or "C". To select the correct positioner model choose either "B" or "C"
* Can be split ranged 2:1 or 3:1without additional parts. from the DF Series cam Characteristics chart.
** The cam can be turned over in the field for opposite air action.
SECTION 2: Follower Arm Kits for When installed on a DF Series valve, the signal Vs flow
Pneumatic Linear Actuators characteristics can be either equal percentage or linear based
Stroke Range*** Part Number on air action as well as cam characteristics. See below
1/2 - 1.5 42684 DF Series Cam Characteristics
1/2 - 3 52684 Equal Percentage Linear
1/2 - 4 62684 Air-to-Open B C
5-8 72684 Air-to-Close C B
1/2-4 Consult SECTION 4: - Follower Arms for
Adjustable Factory Pneumatics Rotary Actuators
Actuator Size Part Number
*** For a ½" stroke on a 25 or 50 square-inch actuator, or for a ¾"
stroke on a 100 or 200 square inch actuator, select the short stroke (Inches)
positioner model. 25 71414
50 61824
100 81414

166 / 167, G I D C, Naroda, Ahmedabad : 382330. India


Phone : +91 79 22821619/22823369, Fax : +91 79 22822430
Email : [email protected] / web : www.mascotvalves.com