DC Motors

DMP catalogue
1-200 kW, 5-1000 Nm
List of contents

Introduction ................................................................. p. 3

Options ....................................................................... p. 4

Application data .......................................................... p. 5

Output data ................................................................ p. 7

Dimension drawings, IC06 ......................................... p. 31

Dimension drawings, IC17/37 .................................... p. 33

Dimension drawings, IC666 ....................................... p. 34

Dimension drawings, IC86W ...................................... p. 35

Dimensions, flanges ................................................... p. 36

Order form .................................................................. p. 37


Introduction

DMP d.c. motors are fully Basic design characteristics


laminated, 2 or 4 pole, square
frame.
Output: 1-200 kW
· Fully laminated stator, main
poles and interpoles.
· Brush holders with spring
loaded pressure fingers.
Torque: 5-1000 Nm · Compact
design.
square frame · Prepared for a number of
options and accessories
DMP motor range: · Easy installation of acces- ensuring high flexibility.
sories. · Painting with excellent corro-
Frame size
DMP
Core
lengths
· Large openings in end
shields for easy inspection.
sion resistant properties.
· Conforms with IEC stan-
112-2
112-4
MA, LA
M, L
· Stator windings of varnish
insulated copper wire.
dards.
·· Available as NEMA standard.
132-2 M · Laminated armature core of
high grade insulated electro-
CSA approved.
132-4 S, M, L, LB
plate.
160-4
180-4
S, SO, M, MO, L, LO, LB
A, B, C, D, E, F · Large number of cooling
ducts in armature provide
excellent cooling.
Type designation example :
DMP 180-4E
· Scrambled armature lamina-
tions for low torque ripples.

DM = DC motor
· Armature windings of var-
nished copper designed for
P = Motor type low commutating stresses
180 = Centre height in mm and high mechanical
4 = Number of poles strength.
E = Core length · Armature is impregnated to
ensure high degree of heat
transfer.

3
Options

Frame size DMP 112-2 112-4 132-2 132-4 160 180

Cooling forms
IC06 (IP23) Force ventilated o o o o o o
IC17 (IP23) Single pipe ventilated o o o o o o
IC37 (IP54) Double pipe ventilated o o o o o o
IC410 (IP54) Totally enclosed o o o o o o
IC416 (IP54) Totally enclosed, fan cooled o o o o o o
IC666 (IP54) Air-air cooled o o o o o
IC86W (IP54) Air-water cooled o o o o o
Other cooling forms available

Protection
IP55 o o o o o o

Mounting forms o o o o o o
IM1001 Horizontal foot o o o o o o
IM1002 Horizontal foot, two shaft ends o o o o o o
IM2001 Horizontal foot and flange o o o o o o
IM2011 Vertical foot and flange o o o o o o
Other mounting forms available

Modifications and accessories


Compound winding o o o o o o
Pressure switch o o o o o o
Temperature sensor, interpole o o o o o o
Temperature sensor, field winding o o o o o o
Bearing sensor o o o o o o
Grounding brush o o o o o o
Heating element o o o o o o
Brush wear sensor o o o o o o
Special shaft o o o o o o
Roller bearing d-end o o o o o o
Shaft seal, d-end o o o o o o
Special balance Class ‘R’ o o o o o o
Special paint (RAL colour) o o o o o o
Special corrosion protection o o o o o o
Transparent inspection cover o o o o o o
Brake o o o o o o
Gearbox o o o o o o

Tachos with coupling


REO 444R1 (60v/1000min-1) o o o o o o
TDP 0.2 LT-4 (60v/1000min-1) o o o o o o
Others available

Pulse generators
POG 9 D (1-1250 ppr) o o o o o o
HG650 or DG60L (1024 ppr) o o o o o o
Others available

4
Application data

Standards Heat exchangers


IEC 34 - IEC 72 etc.
Air/water (IC86W): Air/air (IC666):
Insulation
Class H Air/water exchangers are espe- Air/air heat exchangers are
cially recommended for polluted recommended where water is
Temperature rise environment. not available for cooling purpo-
Class F ses.
Standard is for clean water. The output of a motor with
Balance For corrosive water on request. air/air exchanger will be approxi-
IEC 34-14 grade 'N' standard. mately 20% lower compared to
Grade 'R' on request. Position on top of the motor as cooling forms IC06/17/37/86W.
standard. Fan motor at N-end.
Overload capacity Water connection flanges at Position: On top of the motor as
180% xFLC for right hand side (facing D-end). standard.
15 sec. every 5 minutes Max. water pressure 10 PSI
30 sec. every 30 minutes Max. inlet water temperature Two constant speed fans at top
250C. A water temperature rise of the heat exchanger to provide
Terminal box of 8-100C must be expected. air circulation for the outer and
Standard position: On right hand inner circuits.
side (facing D-end). For motors with low loads or a
Mounting of terminal box on top low incoming water temperature,
or left hand side on request. a temperature regulator is
DMP motors are delivered with recommended to avoid conden-
a large terminal box IP55 includ- sation in the cooling air circuit
ing knockout openings: and to minimize water consump-
tion.
DMP 112 – 132
2 x Ø 28.5 (PG 21) A constant speed fan circulates
2 x Ø 20.5 (PG 13.5) the internal cooling air. A polya-
Cable entry from Drive end. mide filter is provided for carbon
dust.
DMP 160 – 180
2 x Ø 55 (PG 42) Detailed heat exchanger information on request.
4 x Ø 28.5 (PG 21)
Cable entry from above or
below.

Blower position
Standard: On top of the motor at
the non-drive end.
Other positions on request.

Blower is supplied without filter


as standard.
Filter on request.

Bearings
Grease lubricated ball bearings
as standard.
For belt drive please contact our
sales offices.

5
Application data

Fan blower motor data


DMP Unet , fnet (Y) IY (A) Unet, fnet (∆) I∆ (A) Pfan (kW) Wfan (kg)
112 3x380-420 V. 50 Hz 0.70 3x220-240 V. 50 Hz 1.20 0.25 7
132-2M 3x440-480 V. 60 Hz 0.70 3x250-280 V. 60 Hz 1.20 0.30
132-4S/M/L 3x500 V. 50 Hz 0.60 - - 0.25

132-4LB 3x380-420 V. 50 Hz 2.10 3x220-240 V. 50 Hz 3.60 0.75 16


160-4S/M/L 3x440-480 V. 60 Hz 2.00 3x250-280 V. 60 Hz 3.50 0.90
3x500 V. 50 Hz 1.40 - - 0.75

160-4LB 3x380-420 V. 50 Hz 2.90 3x220-240 V. 50 Hz 5.00 1.30 18


3x440-480 V. 60 Hz 2.80 3x250-280 V. 60 Hz 5.00 1.50
3x500 V. 50 Hz 2.30 - - 1.30

180-4A/B/C/D 3x380-420 V. 50 Hz 3.00 3x220-240 V. 50 Hz 5.20 1.50 18


3x440-480 V. 60 Hz 2.90 3x250-280 V. 60 Hz 5.00 1.75
3x500 V. 50 Hz 2.70 - - 1.50

180-4E/F 3x380-420 V. 50 Hz 5.80 3x220-240 V. 50 Hz 10.0 2.70 20


3x440-480 V. 60 Hz 5.80 3x250-280 V. 60 Hz 10.0 3.00
3x500 V. 50 Hz 4.60 - - 2.70
Unet , fnet (Y) Supply voltage, frequency Y
IY Current Y
Pfan Power
Unet , fnet (∆) Supply voltage, frequency ∆
I∆ Current ∆
Wfan Total fan weight

Bearings
Drive end Non-drive end

DMP Ball bearing Roller bearing

112 6308-C3 NU 308 ECP 6208-2RS 1-HT-C3


132 6309-C3 NU 309 ECP 6307-2RS 1-HT-C3
160 6310-C3 NU 310 ECP 6309-2RS 1-HT-C3
180-4A/B/C/D/E 6215-C3 NU 2215-ECP 6312-2RS1-HT-C3
180-4F 6315-C3 NU 315 ECP 6312-2RS1-HT-C3

6
Output data

Select motor frame size against Duty cycles Stock motors


voltage, output and speed. For Ratings: All outputs are duty Motors indicated with the sign ✱
intermediate output, take the type S 1 and motors are fed in the output data lists are
nearest higher output listed from a 3-phase fully controlled available from stock and can be
under the next frame size. For thyristor where the form factor delivered promptly.
intermediate speed take the is 1.05. The stock motors are available
next lower speed listed within according to following specifica-
the output required. The output Field windings tion. Motor fan, standard tacho-
lists are based on: All motors in the output lists generator and coupling can be
have separate excitation, the fitted on request.
• Cooling forms field being shunt wound.
IC06/IC17/IC37/IC86W. Compound winding can be • IM 1001, IP 23, IC 17, desig-
supplied on request. ned for cooling air inlet at
• The armature circuit resis- Motors with compound winding either D or N-end (when
tance listed is for duty may have nominal data which possible, cooling air inlet
warm condition. differ from those shown in the should always be at the D-
output lists. end of DMP motors).
• The inductance listed is for
the armature circuit. Armature voltage • Cylindrical roller bearing on
For other armature voltages, D-end.
• Motor supply from 3-phase please contact our sales offices.
fully controlled thyristor. • Terminal box on right hand
Ambient temperature and side (facing D-end).
Constant power/constant altitude
torque Outputs in this catalogue are • Balanced with half key.
The full field or base speed and based on max. 400C ambient
maximum speed through field temperature and motor located • Thermostats NC.
control with constant output is at max. 1000 metres above sea
listed for each winding. level. • PTC thermistors.
Armature voltage: For -10% the If ambient temperature and/or
output and speed are proportio- altitude is higher, contact our • Name plate and documents
nal to the voltage. sales office. in English.
For higher shunt field ranges,
please refer to sales offices. NEMA output data • Rating data as standard
With a combination of armature NEMA catalogue available on motors but field weakening
voltage/shunt control greater request. is only allowed up to 25 %
constant power ranges can be overspeed for stock
obtained. motors.

• Stock motors have a paral-


lel /serial connection sui-
table for an excitation volta-
ge of 170-180-190/340-360-
380 V.

• Stock motors have reinfor-


ced impregnation.

7
Output data

Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)

nmax Max mechanical speed


n0 Min speed at constant torque
J Moment of inertia
Pf Excitation power
Uamax Max rated voltage
Uf Excitation voltage
Vcool Cooling air flow
Pr Static pressure drop (IC17, IC37)
W(foot) Weight: foot mounting *
W(flange) Weight: flange mounting *

*excl. accessories

Cat. Nr Ua (V): 400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157… nb (min-1) (kW) (A) (Nm) (%) min-1 (Ω) (mH)

nb Base speed
Ua Armature voltage
P Mechanical power
I Armature current
T Torque

h Efficiency IEC
n2 Max electrical speed
RA Armature resistance
LA Armature inductance

Data subject to change without prior notice.

8
30 Nm 112-2MA
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.03 kgm2 420 W 620 V 110-440 V 235 m3/h 375 Pa 90 kg 102 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 154... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
241-AB 1000 3.2 12.2 31.0 61.1 1605 9.84 120
1075 3.5 12.2 31.0 62.8
1145 3.7 12.2 31.0 64.1
1255 4.1 12.2 31.0 66.0
1440 4.6 12.0 30.4 68.9
241-BB 645 2.0 13.5 29.1 50.3 1960 7.78 88
1235 3.8 13.5 29.3 65.0
1315 4.0 13.5 29.3 66.2
1400 4.3 13.5 29.3 67.5
1525 4.7 13.5 29.3 69.2
1745 5.3 13.3 28.8 71.8
241-CB 860 2.8 17.0 30.8 57.4 2480 5.14 61
1570 5.1 17.0 30.8 70.0
1670 5.4 17.0 30.8 71.2
1770 5.7 17.0 30.8 72.2
1920 6.2 17.0 30.8 73.6
2180 6.9 16.7 30.3 75.8
251-CB 1010 3.2 18.5 30.2 61.1 3060 4.21 49
1795 5.7 18.5 30.2 61.1
1905 6.0 18.5 30.2 73.5
2015 6.4 18.5 30.2 74.5
2185 6.9 18.5 30.2 75.7
2475 7.7 18.2 29.7 77.7
241-DB 1185 3.8 21.0 30.4 64.4 3250 3.33 39
2070 6.6 21.0 30.4 74.8
2195 7.0 21.0 30.4 75.7
2320 7.4 21.0 30.4 76.5
2510 8.0 21.0 30.4 77.7
2832 8.9 20.7 29.9 79.4
241-EB* 1445 4.5 23.7 30.0 69.1 3835 2.42 30
2450 7.7 23.7 30.0 77.9
2595 8.2 23.7 30.0 78.7
2740 8.6 23.7 30.0 79.4
2955 9.3 23.7 30.0 80.4
3325 10.3 23.3 29.5 81.8
231-EB 1740 5.8 29.0 31.6 72.3 3595 1.75 30
2920 9.6 29.0 31.5 80.1
3085 10.2 29.0 31.5 80.8
3255 10.7 29.0 31.5 81.4
231-FB 2175 7.0 34.0 30.8 75.7 3835 1.25 15
3590 11.5 34.0 30.7 82.3
3790 12.2 34.0 30.7 82.9
3995 12.8 34.0 30.7 83.4
231-GB1 2820 8.7 41.0 29.6 79.0 5000 0.85 10
4590 14.2 41.0 29.6 84.3

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

9
43 Nm 112-2LA
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.04 kgm2 500 W 620 V 110-440 V 235 m3/h 375 Pa 96 kg 108 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T h n2 RA (115°C) LA (0Hz)


FR 154... nb (min )
-1
(kW) (A) (Nm) (%) min 115°C (Ω)
-1
(mH)
141-AB 655 3.0 12.2 44.3 56.3 1055 11.51 164
705 3.3 12.2 44.3 58.1
755 3.5 12.2 44.3 59.7
830 3.9 12.2 44.3 61.8
964 4.4 12.0 43.6 65.3
151-AB 725 3.5 13.5 45.6 58.6 1280 9.85 141
780 3.7 13.5 45.6 60.2
835 4.0 13.5 45.6 61.8
915 4.4 13.5 45.7 63.8
1058 5.0 13.3 44.8 67.1
141-BB 790 3.5 13.7 42.6 59.0 1275 9.52 121
850 3.8 13.7 42.6 60.7
910 4.0 13.7 42.6 62.2
1000 4.5 13.7 42.7 64.3
1153 5.1 13.5 41.9 67.4
141-CB 1040 4.8 17.0 44.0 65.5 1650 6.29 83
1110 5.1 17.0 44.0 66.8
1180 5.4 17.0 44.0 68.1
1285 5.9 17.0 44.1 69.8
1472 6.7 16.7 43.3 72.5
141-DB 645 2.9 18.5 42.9 54.8 1895 5.16 67
1200 5.4 18.5 43.1 68.5
1275 5.8 18.5 43.1 69.7
1355 6.1 18.5 43.2 70.8
1470 6.7 18.5 43.1 72.4
1674 7.5 18.2 42.5 74.8
141-EB 770 3.5 21.0 43.4 58.7 2200 4.07 54
1390 6.3 21.0 43.5 71.2
1480 6.7 21.0 43.5 72.3
1570 7.1 21.0 43.5 73.4
1705 7.8 21.0 43.6 74.8
1933 8.7 20.7 42.7 77.0
141-FB 950 4.3 24.0 43.5 64.2 2610 2.97 41
1660 7.6 24.0 43.5 75.0
1765 8.0 24.0 43.5 76.0
1865 8.5 24.0 43.5 76.9
2020 9.2 24.0 43.5 78.1
2278 10.2 23.6 42.8 79.9
141-GB* 1165 5.5 29.2 45.1 68.5 3120 2.13 30
1995 9.4 29.0 45.2 77.9
2110 10.0 29.0 45.2 78.7
2230 10.5 29.0 45.2 79.5
2410 11.4 29.0 45.1 80.6
2710 12.6 28.5 44.4 82.2
131-CB* 1305 6.2 32.0 45.7 70.7 3120 1.76 25
2210 10.6 32.0 45.7 79.4
2340 11.2 32.0 45.7 80.2
2470 11.8 32.0 45.7 80.0
2665 12.7 32.0 45.7 81.9
2993 14.1 31.5 44.9 83.3
141-HB 1470 6.8 34.0 44.0 72.6 3850 1.52 21
2465 11.4 34.0 44.0 80.7
2610 12.0 34.0 44.0 81.4
2750 12.7 34.0 44.0 82.0
2965 13.7 34.0 44.1 82.9
3326 15.1 33.4 43.3 84.2
141-KB* 1675 7.8 38.0 44.3 75.0 4340 1.22 17
2785 12.9 38.0 44.3 82.3
2940 13.6 38.0 44.3 82.9
3100 14.4 38.0 44.3 83.5
3335 15.5 38.0 44.3 84.3

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

10
47 Nm 112-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.037 kgm2 625 W 550 V 110-440 V 270 m3/h 480 Pa 103 kg 115 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 153... nb (min )
-1
(kW) (A) (Nm) (%) min 115°C (Ω)
-1
(mH)
201-NA 1325 6.7 21.0 47.9 75.1 1655 3.258 40.75
1405 7.1 21.0 47.9 76.0 1655
1485 7.5 21.0 47.9 76.9 1655
1605 8.1 21.0 47.9 78.0 1655
1810 8.3 19.2 43.8 80.1 1810
201-MA 1445 7.1 22.0 47.1 76.8 1795 2.776 35.80
1530 7.5 22.0 47.1 77.7 1795
1615 8.6 22.0 47.0 78.5 1795
1745 8.6 22.0 47.0 79.5 1795
1960 8.8 20.1 43.1 81.3 1960
201-LA 920 4.6 24.0 48.0 68.9 1890 2.416 31.20
1565 7.8 24.0 47.9 77.9 1890
1655 8.3 24.0 47.9 78.7 1890
1745 8.8 24.0 47.9 79.5 1890
1890 9.4 24.0 47.9 80.4 1890
2115 9.5 21.4 42.8 81.9 2115
201-KA 1010 4.9 25.0 46.3 70.2 2105 2.174 26.90
1700 8.2 25.0 46.3 78.8 2105
1800 8.7 25.0 46.3 79.5 2105
1900 9.2 25.0 46.3 80.2 2105
2050 9.9 25.0 46.3 81.2 2105
2295 10.2 22.9 42.4 82.5 2295
201-JA 1120 5.5 27.5 47.0 72.5 2435 1.783 22.90
1870 9.2 27.5 47.0 80.3 2435
1980 9.7 27.5 47.0 81.0 2435
2085 10.3 27.5 47.0 81.7 2435
2245 11.1 27.5 47.0 82.5 2435
2515 12.0 26.6 45.5 83.7 2515
201-IA 1240 6.1 30.0 46.7 73.8 2655 1.549 19.25
2060 10.1 30.0 46.6 81.2 2655
2175 10.6 30.0 46.6 81.9 2655
2295 11.2 30.0 46.6 82.5 2655
2470 12.0 30.0 46.6 83.3 2655
2760 12.9 28.8 44.8 84.4 2760
201-HA 1390 6.8 33.0 46.7 75.7 2920 1.275 15.90
2295 11.2 33.0 46.6 82.5 2920
2420 11.8 33.0 46.6 83.1 2920
2550 12.4 33.0 46.6 83.6 2920
2745 13.4 33.0 46.6 84.4 2920
3065 14.2 31.4 44.3 85.4 3065
201-GA 1575 8.2 39.0 50.0 77.9 2975 0.973 12.90
2575 13.5 39.0 49.9 84.0 2975
2720 14.2 39.0 49.9 84.6 2975
2860 14.9 39.0 49.9 85.0 2975
3080 15.5 37.7 48.2 85.7 3080
201-FA 1800 9.4 44.0 49.9 79.7 3425 0.772 10.20
2930 15.3 44.0 49.8 85.2 3425
3090 16.1 44.0 49.8 85.7 3425
3250 17.0 44.0 49.8 86.1 3425
3500 17.8 43.0 48.7 86.7 3500
201-EA 2100 11.2 51.0 51.0 81.8 3855 0.573 7.80
3390 18.0 51.0 50.8 86.6 3855
3575 19.0 51.0 50.8 87.0 3855
3760 20.0 51.0 50.8 87.3 3855
201-DA 2495 13.4 60.0 51.3 83.5 4460 0.425 5.75
4000 21.4 60.0 51.1 87.7 4460
201-CA 3055 15.9 70.0 49.8 85.4 5000 0.298 4.00

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

11
68 Nm 112-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.05 kgm2 740 W 550 V 110-440 V 270 m3/h 480 Pa 110 kg 122 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T h n2 RA (115°C) LA (0Hz)


FR 153... nb (min )
-1
(kW) (A) (Nm) (%) min 115°C (Ω)
-1
(mH)
101-KA 1160 7.9 25.0 65.2 75.0 1545 2.679 32.75
1230 8.4 25.0 65.2 76.0 1545
1300 8.9 25.0 65.2 76.8 1545
1405 9.6 25.0 65.2 77.9 1545
101-JA 1280 8.9 27.5 66.2 76.9 1790 2.196 27.90
1355 9.4 27.5 66.2 77.8 1790
1435 9.9 27.5 66.2 78.5 1790
1545 10.7 27.5 66.2 79.6 1790
1735 12.0 27.5 66.2 81.0 1790
101-IA* 1410 9.8 30.0 66.2 77.9 1950 1.908 23.45
1495 10.4 30.0 66.2 78.7 1950
1575 10.9 30.0 66.1 79.5 1950
1700 11.8 30.0 66.1 80.4 1950
1910 13.2 30.0 66.1 81.8 1950
101-HA 1575 10.9 33.0 66.2 79.5 2145 1.569 19.40
1670 11.6 33.0 66.2 80.2 2145
1760 12.2 33.0 66.1 80.9 2145
1895 13.1 33.0 66.1 81.7 2145
2125 14.7 33.0 66.1 83.0 2145
101-GA 1070 7.9 39.0 70.6 74.0 2240 1.195 15.70
1790 13.1 39.0 70.5 81.3 2240
1880 13.9 39.0 70.5 82.0 2240
1980 14.6 39.0 70.5 82.6 2240
2135 15.7 39.0 70.4 83.3 2240
101-FA* 1230 9.1 44.0 70.8 76.2 2515 0.947 12.40
2030 15.0 44.0 70.6 82.8 2515
2145 15.8 44.0 70.6 83.3 2515
2255 16.7 44.0 70.6 83.9 2515
2425 17.9 44.0 70.6 84.6 2515
101-EA* 1445 10.9 51.0 71.8 78.7 2835 0.708 9.50
2355 17.7 51.0 71.6 84.4 2835
2485 18.6 51.0 71.6 84.9 2835
2615 19.6 51.0 71.6 85.3 2835
101-DA* 1720 13.0 60.0 72.2 80.7 3280 0.526 7.00
2785 21.0 60.0 72.0 85.7 3280
2935 22.1 60.0 72.0 86.2 3280
3085 23.3 60.0 72.0 87.0 3280
101-CA 2115 15.5 70.0 70.2 83.0 4050 0.368 4.85
3390 24.8 70.0 69.9 87.1 4050
3575 26.1 70.0 69.9 87.5 4050
3755 27.5 70.0 69.8 87.8 4050
101-BA 2705 18.6 82.0 65.5 84.9 5000 0.251 3.10
4300 29.3 82.0 65.2 88.1 5000
4525 30.9 82.0 65.1 88.4 5000
4755 32.4 82.0 65.1 88.6 5000
101-AA 3690 23.0 100.0 59.5 86.7 5000 0.149 1.75

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

12
65 Nm 132-2M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.09 kgm2 550 W 620 V 110-440 V 435 m3/h 400 Pa 132 kg 147 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 154... nb (min )
-1
(kW) (A) (Nm) (%) min 115°C (Ω)
-1
(mH)
241-AB 605 4.0 16.4 63.1 56.1 1460 8.93 132
650 4.3 16.4 63.1 57.9 1480
700 4.6 16.4 63.1 59.5 1480
770 5.1 16.4 63.4 61.7 1480
898 5.8 16.1 62.1 65.2 1480
241-BB 830 5.6 20.5 64.3 63.7 1725 5.73 87
885 6.0 20.5 64.3 65.1 1725
945 6.4 20.5 64.3 66.5 1725
1035 7.0 20.5 64.3 68.3 1725
1186 7.9 20.2 63.3 71.2 1725
241-CB 980 6.6 23.3 64.6 67.0 1950 4.50 68
1045 7.1 23.3 64.6 68.3 1950
1110 7.5 23.3 64.6 69.5 1950
1210 8.2 23.3 64.6 71.2 1950
1383 9.2 22.9 63.5 73.8 1950
241-DB 1200 8.3 27.5 66.1 71.7 2200 3.18 51
1275 8.8 27.5 66.1 72.8 2200
1350 9.3 27.5 66.1 73.9 2200
1465 10.1 27.5 66.1 75.3 2200
1664 11.3 27.0 65.0 77.5 2200
231-AB 745 5.3 30.5 67.6 62.2 1860 2.60 43
1330 9.4 30.5 67.7 73.8 1860
1415 10.0 30.5 67.7 74.9 1860
1495 10.6 30.5 67.7 75.8 1860
1620 11.5 30.5 67.7 77.1 1860
1835 12.8 30.0 66.5 79.0 1860
251-EB 830 5.6 32.0 64.9 63.6 2650 2.37 36
1465 10.0 32.0 65.0 74.8 2650
1555 10.6 32.0 65.0 75.8 2650
1650 11.2 32.0 65.0 76.7 2650
1785 12.2 32.0 65.1 77.9 2650
2019 13.5 31.5 63.9 79.9 2650
241-EB 945 6.6 36.0 66.5 66.5 2840 1.93 30
1650 11.5 36.0 66.4 76.7 2840
1750 12.2 36.0 66.4 77.7 2840
1850 12.9 36.0 66.4 78.5 2840
2000 13.9 36.0 66.4 79.6 2840
2257 15.4 35.4 65.3 81.4 2840
251-FB 1100 7.7 40.0 66.5 70.1 3160 1.51 24
1880 13.1 40.0 66.5 79.1 3160
1990 13.9 40.0 66.5 79.9 3160
2105 14.6 40.0 66.5 80.7 3160
2270 15.8 40.0 66.5 81.7 3160
2554 17.5 39.3 65.3 83.2 3160
241-FB 1280 9.1 46.0 68.0 73.0 3480 1.16 19
2155 15.4 46.0 68.1 81.1 3480
2280 16.3 46.0 68.1 81.8 3480
2405 17.1 46.0 68.1 82.5 3480
2595 18.5 46.0 68.1 83.3 3480
2911 20.4 45.2 66.9 84.7 3480
241-GB 1505 10.6 52.0 67.3 75.4 4000 0.92 15
2500 17.6 52.0 67.3 82.7 4000
2645 18.7 52.0 67.3 83.3 4000
2790 19.7 52.0 67.3 83.9 4000
3000 21.2 52.0 67.4 84.7 4000
231-DB 1820 12.7 60.0 66.9 78.7 4000 0.65 11
2990 20.8 60.0 66.6 84.9 4000
3155 22.0 60.0 66.6 85.4 4000
3320 23.2 60.0 66.6 85.9 4000
231-EB 2240 15.6 72.0 66.5 81.0 4000 0.47 8
3640 25.3 72.0 66.5 86.3 4000

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

13
100 Nm 132-4S
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.10 kgm2 750 W 620 V 110-440 V 470 m3/h 550 Pa 115 kg 130 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 156... nb (min )
-1
(kW) (A) (Nm) (%) min 115°C (Ω)
-1
(mH)
341-AB 690 7.7 27.5 107.0 65.6 1250 4.01 60.30
737 8.2 27.5 107.0 67.0 1250
785 8.8 27.5 107.0 68.3 1250
855 9.6 27.5 107.0 70.0 1250
980 10.8 27.0 105.0 72.8 1250
341-BB 820 9.1 31.0 106.0 69.0 1410 3.16 46.20
875 9.7 31.0 106.0 70.3 1410
930 10.3 31.0 106.0 71.4 1410
1015 11.2 31.0 105.0 73.0 1410
1155 12.5 30.5 104.0 75.5 1410
341-CB 555 5.9 35.0 102.0 60.1 1750 2.41 33.90
1000 10.7 35.0 102.0 72.5 1750
1065 11.4 35.0 102.0 73.6 1750
1130 12.1 35.0 102.0 74.7 1750
1225 13.1 35.0 102.0 76.0 1750
1390 14.6 34.4 100.0 78.2 1750
341-DB 720 7.9 43.0 105.0 66.2 2000 1.61 23.60
1260 13.8 43.0 105.0 76.7 2000
1335 14.6 43.0 105.0 77.6 2000
1410 15.4 43.0 105.0 78.5 2000
1525 16.7 43.0 105.0 79.6 2000
1720 18.5 42.3 103.0 81.4 2000
341-EB* 835 9.4 49.0 107.0 69.5 2160 1.26 19.40
1430 16.0 49.0 107.0 78.9 2160
1515 17.0 49.0 107.0 79.7 2160
1600 18.0 49.0 107.0 80.5 2160
1730 19.4 49.0 107.0 81.5 2160
1945 21.5 48.2 105.0 83.1 2160
341-FB 980 10.2 51.0 99.0 72.6 2630 1.04 15.30
1650 17.1 51.0 99.1 80.9 2630
1745 18.1 51.0 99.1 81.7 2630
1840 19.1 51.0 99.1 82.3 2630
1985 20.6 51.0 99.0 83.2 2630
2230 22.7 50.2 97.4 84.6 2630
341-GB* 1150 12.7 62.0 106.0 75.4 2920 0.77 11.80
1915 21.2 62.0 105.0 82.8 2920
2025 22.4 62.0 105.0 83.5 2920
2135 23.6 62.0 105.0 84.1 2920
2300 25.4 62.0 105.0 84.9 2920
2580 27.9 61.0 104.0 86.1 2920
341-HB 1380 14.5 69.0 100.0 77.6 3750 0.61 8.70
2270 23.9 69.0 101.0 84.3 3750
2395 25.2 69.0 101.0 84.8 3750
2525 26.6 69.0 100.0 85.4 3750
2720 28.6 69.0 100.0 86.1 3750
3040 31.4 67.9 98.7 87.2 3750
341-KB 1725 16.2 74.0 89.7 81.1 4000 0.45 5.03
2795 26.2 74.0 89.6 86.4 4000
2945 27.6 74.0 89.6 86.9 4000
3100 29.1 74.0 89.4 87.3 4000
3335 31.2 74.0 89.4 87.8 4000
3715 34.2 72.8 87.9 88.7 4000
331-GB 2220 22.6 100.0 97.0 84.3 4000 0.26 3.20
3560 36.1 100.0 96.8 88.5 4000
3750 38.0 100.0 96.8 88.9 4000
3945 39.9 100.0 96.7 89.3 4000

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

14
135 Nm 132-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.12 kgm2 830 W 620 V 110-440 V 470 m3/h 550 Pa 145 kg 160 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 156... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
241-AB 730 10.2 35.0 133.0 68.8 1200 2.81 42.0
780 10.9 35.0 133.0 70.1 1200
830 11.6 35.0 133.0 71.3 1200
900 12.6 35.0 133.0 72.8 1200
1030 14.1 34.4 131.0 75.4 1200
241-BB 515 7.4 43.0 137.0 61.6 1410 1.88 29.2
930 13.3 43.0 137.0 73.6 1410
985 14.1 43.0 137.0 74.7 1410
1045 15.0 43.0 137.0 75.7 1410
1130 16.2 43.0 137.0 77.0 1410
1285 18.0 42.3 134.0 79.1 1410
241-CB 605 8.9 49.0 140.0 65.6 1520 1.46 23.6
1060 15.6 49.0 140.0 76.2 1520
1125 16.5 49.0 140.0 77.2 1520
1190 17.5 49.0 140.0 78.1 1520
1285 18.9 49.0 140.0 79.2 1520
1455 21.0 48.2 138.0 81.1 1520
241-DB 715 9.7 51.0 130.0 69.0 1860 1.22 18.7
1230 16.7 51.0 130.0 78.5 1860
1300 17.7 51.0 130.0 79.3 1860
1375 18.6 51.0 130.0 80.1 1860
1480 20.1 51.0 130.0 81.1 1860
1670 22.3 50.2 127.0 82.8 1860
241-EB 845 12.2 62.0 138.0 72.2 2050 0.89 14.2
1430 20.7 62.0 138.0 80.7 2050
1510 21.9 62.0 138.0 81.5 2050
1595 23.1 62.0 138.0 82.2 2050
1720 24.9 62.0 138.0 83.1 2050
1935 27.5 61.0 136.0 84.5 2050
241-FB* 1015 14.0 69.0 132.0 74.8 2500 0.71 10.5
1700 23.4 69.0 132.0 82.4 2500
1795 24.8 69.0 132.0 83.1 2500
1895 26.1 69.0 132.0 83.7 2500
2040 28.1 69.0 132.0 84.5 2500
2290 31.0 67.9 129.0 85.8 2500
241-GB 1285 15.8 74.0 118.0 78.8 3350 0.52 7.3
2100 25.8 74.0 118.0 84.9 3350
2220 27.3 74.0 117.0 85.5 3350
2335 28.7 74.0 117.0 86.0 3350
2515 30.8 74.0 117.0 86.6 3350
2805 33.9 72.8 115.0 87.6 3350
241-HB* 1665 22.1 100.0 127.0 82.5 3900 0.03 4.6
2690 35.7 100.0 127.0 87.4 3900
2835 37.6 100.0 127.0 87.8 3900
2980 39.6 100.0 127.0 88.2 3900
3200 42.5 100.0 127.0 88.7 3900
3570 46.5 98.3 125.0 89.5 3900
231-HB 2280 27.7 122.0 116.0 85.1 4000 0.19 2.6
3645 44.1 122.0 116.0 88.9 4000

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

15
150 Nm 132-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.14 kgm2 1000 W 620 V 110-440 V 470 m3/h 550 Pa 170 kg 185 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 156... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
141-AB 765 11.8 38.5 148.0 72.0 1460 2.14 35.00
810 12.6 38.5 148.0 73.1 1460
860 13.3 38.5 148.0 74.2 1460
930 14.4 38.5 148.0 75.5 1460
1060 16.1 37.9 145.0 77.7 1460
141-BB 495 7.7 43.0 149.0 63.5 1610 1.69 29.00
875 13.6 43.0 149.0 74.7 1610
925 14.4 43.0 149.0 75.7 1610
980 15.3 43.0 149.0 76.7 1610
1060 16.5 43.0 149.0 77.9 1610
1200 18.4 42.3 146.0 79.8 1610
141-CB 580 9.0 48.0 148.0 66.8 1830 1.35 23.00
1000 15.5 48.0 148.0 76.9 1830
1065 16.5 48.0 148.0 77.9 1830
1125 17.4 48.0 148.0 78.7 1830
1215 18.8 48.0 148.0 79.8 1830
1370 20.8 47.2 145.0 81.6 1830
141-DB 690 10.7 55.0 148.0 70.0 2080 1.05 17.00
1170 18.2 55.0 148.0 79.1 2080
1240 19.3 55.0 148.0 79.9 2080
1310 20.3 55.0 148.0 80.7 2080
1415 21.9 55.0 148.0 81.7 2080
1590 24.2 54.1 146.0 83.2 2080
141-EB* 825 13.0 65.0 150.0 72.7 2470 0.08 13.00
1390 21.9 65.0 150.0 81.0 2470
1470 23.1 65.0 150.0 81.7 2470
1550 24.4 65.0 150.0 82.4 2470
1675 26.3 65.0 150.0 83.3 2470
1875 29.0 63.9 148.0 84.7 2470
141-FB* 1045 16.2 77.0 148.0 77.3 3000 0.53 90.00
1720 26.7 77.0 148.0 84.0 3000
1820 28.2 77.0 148.0 84.6 3000
1915 29.7 77.0 148.0 85.1 3000
2060 31.9 77.0 148.0 85.8 3000
2305 35.1 75.7 145.0 86.9 3000
141-GB* 1365 21.6 98.0 151.0 81.5 3780 0.32 60.00
2215 34.9 98.0 151.0 86.8 3780
2335 36.8 98.0 151.0 87.3 3780
2455 38.7 98.0 151.0 87.7 3780
2635 41.5 98.0 151.0 88.2 3780
2940 45.5 96.4 148.0 89.1 3780
141-HB 1880 25.7 114.0 131.0 84.3 4000 0.21 3.00
3010 41.0 114.0 130.0 88.4 4000
3170 43.2 114.0 130.0 88.7 4000
3330 45.4 114.0 130.0 89.1 4000
3570 48.6 114.0 130.0 89.4 4000
3980 53.2 112.0 128.0 90.1 4000

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

16
240 Nm 132-4LB
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.20 kgm2 1350 W 550 V 110-440 V 510 m3/h 810 Pa 220 kg 235 kg

Cat. Nr Ua (V):260 400 420 440 470 520 P I T 


h n2 RA (115°C) LA (0Hz)
FR 156... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
401-AB 465 11.7 43.0 242 65.2 920 2.74 44.5
500 12.6 43.0 242 66.7
530 13.4 43.0 242 68.0
580 14.7 43.0 242 69.8
665 16.6 42.2 237 72.6
401-BB 545 13.5 47.0 238 68.9 1040 2.17 36.1
580 14.5 47.0 238 70.2
620 15.4 47.0 238 71.4
675 16.8 47.0 238 73.0
770 18.8 46.2 234 75.6
401-CB 635 15.3 51.0 229 71.8 1210 1.78 28.5
680 16.3 51.0 229 73.0
720 17.3 51.0 229 74.0
780 18.8 51.0 229 75.5
890 21.0 50.1 225 77.7
401-DB 415 10.3 60.0 236 62.7 1345 1.36 21.8
750 18.5 60.0 236 74.4
795 19.7 60.0 236 75.5
845 20.9 60.0 236 76.5
915 22.6 60.0 236 77.8
1040 25.2 59.0 232 79.9
401-EB 515 12.5 69.0 233 66.8 1645 1.03 16.0
900 22.0 69.0 233 77.2
955 23.3 69.0 233 78.1
1010 24.7 69.0 233 79.0
1095 26.7 69.0 233 80.1
1240 29.6 67.8 229 81.9
401-FB 660 16.5 85.0 239 72.0 1920 0.69 11.1
1125 28.2 85.0 239 80.8
1190 29.8 85.0 239 81.5
1260 31.5 85.0 239 82.5
1360 34.0 85.0 239 83.2
1525 37.5 83.5 235 84.6
401-GB 895 20.9 99.0 223 78.3 2575 0.42 7.1
1475 34.4 99.0 223 84.9
1560 36.4 99.0 223 85.5
1645 38.3 99.0 223 86.0
1770 41.2 99.0 223 86.8
1975 45.2 97.3 219 87.8
401-HB 1235 26.8 123.0 207 81.3 3000 0.28 4.0
2010 43.5 123.0 207 86.8
2120 45.9 123.0 207 87.3
2230 48.3 123.0 207 87.8
2395 51.9 123.0 207 88.4
2670 56.9 121.0 203 89.2

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

17
185 Nm 160-4S
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.22 kgm2 1050 W 550 V 110-440 V 880 m3/h 980 Pa 190 kg 215 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
301-RC 650 12.4 41 182 71.2 980 2.14 33.6
695 13.3 41 182 72.5 980
735 14.0 41 182 73.5 980
800 15.3 41 182 75.0 980
905 17.0 40 179 77.3 980
975 18.0 40 178 78.4 980
301-PC 735 14.0 45 182 73.5 1050 1.75 28.2
775 14.8 45 182 74.5 1050
825 15.7 45 182 75.5 1050
890 17.0 45 182 76.8 1050
1010 19.0 44 179 78.9 1080
1080 20.2 44 178 80.0 1080
301-NC 825 15.9 50 185 75.7 1205 1.44 23.3
875 16.9 50 185 76.7 1205
925 17.9 50 185 77.6 1205
1000 19.4 50 185 78.8 1205
1130 21.5 49 182 80.7 1205
1205 22.9 49 181 81.7 1205
301-MC 935 18.2 56 186 77.6 1400 1.17 18.9
990 19.3 56 186 78.5 1400
1045 20.4 56 186 79.3 1400
1130 22.0 56 186 80.5 1400
1275 24.4 55 183 82.2 1400
1360 25.6 54 180 83.1 1400
301-LC 1075 20.9 63 186 79.8 1575 0.92 14.9
1135 22.2 63 186 80.6 1575
1200 23.4 63 186 81.4 1575
1295 25.3 63 186 82.4 1575
1455 27.9 62 183 83.9 1575
1550 29.3 61 181 84.7 1575
301-KC 1245 24.3 72 187 81.5 1850 0.72 11.5
1320 25.7 72 187 82.3 1850
1390 27.1 72 187 82.9 1850
1500 29.3 72 187 83.9 1850
1680 32.3 71 183 85.3 1850
1795 34.0 70 181 86.0 1850
301-HC 1490 29.5 85 189 84.1 2125 0.50 8.4
1575 31.1 85 189 84.7 2125
1660 32.8 85 189 85.3 2125
1785 35.3 85 189 86.0 2125
2000 38.8 84 186 87.2 2125
2125 41.0 83 184 87.8 2125
301-GC* 1830 36.1 102 189 86.2 2470 0.35 5.9
1930 37.9 102 189 86.7 2470
2030 40.1 102 189 87.2 2470
2180 42.9 102 189 87.9 2470
2440 47.3 100 185 88.9 2590
2590 49.6 99 183 89.4 2590
301-FC 2330 45.8 127 188 88.4 3325 0.22 3.8
2455 48.3 127 188 88.8 3325
2580 50.8 127 188 89.2 3325
2770 54.5 127 188 89.7 3325
3090 59.7 125 185 90.5 3325
3280 62.9 124 183 90.9 3325
301-EB 2630 51.6 142 188 89.8 3500 0.18 3.0
2770 54.4 142 188 90.2 3500
2910 57.2 142 188 90.6 3500
3120 61.3 142 188 91.0 3500
3480 67.1 140 184 91.7 3500
301-EC 3165 61.0 166 184 90.4 3500 0.13 2.1
3335 64.2 166 184 90.7 3500

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

18
210 Nm 160-4SO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.24 kgm2 1050 W 550 V 110-440 V 880 m3/h 980 Pa 200 kg 225 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 156... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
601-RC 680 14.8 47 208 75.4 1075 1.59 26.3
720 15.7 47 208 76.4
765 16.7 47 208 77.3
830 18.0 47 208 78.6
935 20.1 46 205 80.5
1000 21.2 46 203 81.5
601-PC 755 16.4 51 207 76.9 1180 1.36 22.1
800 17.4 51 207 77.9
845 18.4 51 207 78.7
915 19.9 51 207 79.5
1035 22.0 50 204 81.7
1105 23.3 50 202 82.6
601-NC 845 18.7 57 211 78.9 1280 1.12 18.3
900 19.8 57 211 79.8
950 20.9 57 211 80.5
1025 22.6 57 211 81.6
1150 24.9 56 207 83.0
1225 26.3 55 205 83.9
601-MC 955 20.9 63 210 80.3 1430 0.92 14.9
1010 22.2 63 210 81.1
1065 23.4 63 210 81.9
1150 25.3 63 210 82.8
1295 27.9 62 206 84.3
1380 29.5 61 204 85.1
601-LC 1095 24.4 72 213 82.3 1580 0.71 11.7
1160 25.8 72 213 83.1
1220 27.3 72 213 83.7
1315 29.4 72 213 84.6
1475 32.4 71 210 85.9
1575 33.8 69 205 86.6
601-KC 1275 28.5 83 214 84.1 1800 0.54 9.0
1345 30.1 83 214 84.8 1800
1420 31.7 83 214 85.3 1800
1525 34.1 83 214 86.1 1800
1710 37.6 81 210 87.3 1825
1825 38.6 78 202 88.0 1825
601-HC 1515 34.1 97 215 86.0 2095 0.40 6.6
1595 36.0 97 215 86.5 2095
1680 37.9 97 215 87.0 2095
1805 40.7 97 215 87.7 2095
2020 44.7 95 212 88.7 2095
2155 45.1 90 200 89.4 2155
601-GC 1845 41.1 115 213 87.7 2545 0.28 4.6
1950 43.4 115 213 88.2 2545
2050 45.6 115 213 88.6 2545
2200 49.0 115 213 89.2 2545
2460 53.8 113 209 90.1 2545
2615 54.1 107 197 90.6 2615
601-GB 2020 43.2 120 204 88.7 3000 0.25 4.0
2130 45.5 120 204 89.1
2240 47.9 120 204 89.5
2400 51.4 120 204 90.0
2680 56.3 118 201 90.8
2850 59.2 117 198 91.2
601-FC 2350 52.5 144 213 89.7 3170 0.18 2.9
2480 55.3 144 213 90.1 3170
2605 58.1 144 213 90.5 3170
2795 62.3 144 213 90.9 3170
3115 67.6 140 207 91.6 3170
3315 67.5 132 195 91.9 3315
601-EB 2640 56.4 154 204 90.5 3500 0.15 2.4
2780 59.4 154 204 90.8
2920 62.4 154 204 91.1
3140 66.9 154 204 91.6
3490 73.2 151 200 92.2
601-EC1 3190 70.0 189 210 91.6 3500 0.10 1.7
3360 73.7 189 210 91.8

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

19
240 Nm 160-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.25 kgm2 1250 W 550 V 110-440 V 880 m3/h 980 Pa 230 kg 245 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
201-NC 620 15.4 50 237 72.5 925 1.64 28.30
660 16.4 50 237 73.6 925
700 17.4 50 237 74.7 925
760 18.8 50 237 76.0 925
860 21.0 50 233 78.2 925
920 22.3 50 232 79.3 925
201-MC 710 17.6 56 238 74.6 1125 1.33 22.90
750 18.7 56 238 75.6 1125
795 19.8 56 238 76.6 1125
860 21.5 56 238 77.9 1125
975 23.9 55 234 79.9 1125
1040 25.1 54 230 80.9 1125
201-LC 815 20.4 63 239 77.1 1265 1.05 18.10
865 21.6 63 239 78.0 1265
915 22.9 63 239 78.9 1265
990 24.7 63 239 80.0 1265
1115 27.4 62 235 81.8 1265
1190 28.8 61 231 82.7 1265
201-KC 950 23.8 72 238 79.1 1490 0.83 13.85
1010 25.2 72 238 79.9 1490
1065 26.6 72 238 80.7 1490
1150 28.7 72 238 81.7 1490
1295 31.7 71 234 83.3 1490
1380 33.5 70 232 84.2 1490
201-HC 1145 28.9 85 242 82.0 1690 0.58 10.20
1210 30.6 85 242 82.8 1690
1275 32.2 85 242 83.4 1690
1375 34.7 85 242 84.3 1690
1540 38.3 84 237 85.6 1690
1640 40.5 83 235 86.3 1690
201-GC* 1410 35.5 102 241 84.4 2000 0.4 7.05
1485 37.4 102 241 85.0 2000
1565 39.5 102 241 85.6 2000
1680 42.3 102 241 86.3 2000
1885 46.7 100 237 87.5 2000
2000 48.6 98 232 88.1 2000
201-FC 1800 45.2 127 240 86.9 2675 0.25 4.50
1895 47.7 127 240 87.4 2675
1995 50.2 127 240 87.9 2675
2145 53.9 127 240 88.5 2675
2390 59.2 125 236 89.4 2675
2540 62.4 124 234 89.8 2675
201-EB 2030 50.3 140 237 88.6 2980 0.21 3.63
2140 53.1 140 237 89.0 2980
2250 55.8 140 237 89.4 2980
2420 59.9 140 237 89.9 2980
2700 65.6 138 233 90.7 2980
2860 69.0 136 230 91.0 2980
201-EC* 2450 60.4 166 235 89.2 3500 0.15 2.55
2580 63.6 166 235 89.6 3500
2715 66.8 166 235 90.0 3500
2910 71.7 166 235 90.4 3500
3245 78.5 163 231 91.1 3500
201-CB 2920 73.5 200 241 91.0 3500 0.09 1.85
3075 77.4 200 241 91.2 3500
3230 81.2 200 240 91.5 3500
3460 87.0 200 240 91.8 3500

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

20
270 Nm 160-4MO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.27 kgm2 1250 W 550 V 110-440 V 880 m3/h 980 Pa 230 kg 255 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
501-NC 640 18.1 57 270 75.9 1035 1.28 23.6
680 19.2 57 270 76.9
720 20.3 57 270 77.8
780 22.0 57 270 79.0
880 24.4 56 265 80.9
940 25.8 55 263 81.9
501-MC 725 20.4 63 269 77.7 1150 1.05 19.1
770 21.7 63 269 78.7
815 22.9 63 269 79.5
880 24.7 63 269 80.6
995 27.4 62 264 82.3
1060 29.0 61 261 83.2
501-LC 840 23.9 72 273 80.1 1275 0.81 15.1
885 25.3 72 273 80.9
935 26.8 72 273 81.6
1010 28.9 72 273 82.6
1135 31.9 71 269 84.1
1210 33.6 70 265 84.9
501-KC 975 28.0 83 274 82.1 1450 0.62 11.6
1035 29.6 83 274 82.9
1090 31.2 83 274 83.5
1175 33.7 83 274 84.4
1315 37.1 81 269 85.7
1405 39.1 80 266 86.4
501-HC 1165 33.6 97 276 84.3 1680 0.45 8.5
1230 35.5 97 276 84.9
1295 37.4 97 276 85.4
1395 40.3 97 276 86.2
1560 44.3 95 271 87.4
1660 46.6 94 268 88.0
501-GC 1425 40.6 115 273 86.3 2045 0.32 5.9
1505 42.9 115 273 86.9
1585 45.2 115 273 87.4
1700 48.5 115 273 88.0
1905 53.3 113 268 89.1
2020 56.1 112 265 89.6
501-GB 1560 42.5 120 260 87.1 2420 0.29 4.9
1650 44.9 120 260 87.6
1730 47.2 120 260 88.0
1860 50.7 120 260 88.6
2080 55.6 118 256 89.5
2210 58.5 117 253 89.9
501-FC 1820 52.0 144 273 88.6 2560 0.20 3.8
1915 54.8 144 273 89.0
2015 57.6 144 273 89.4
2165 61.8 144 273 90.0
2415 67.8 142 268 90.7
2560 71.2 140 265 91.1
501-EB 2050 55.8 154 261 89.4 3110 0.18 2.9
2160 58.8 154 261 89.8
2270 61.8 154 261 90.1
2430 66.3 154 261 90.7
2710 72.6 151 256 91.3
2880 76.3 150 253 91.7
1
501-EC 2470 69.5 189 269 90.7 3420 0.12 2.1
2605 73.2 189 269 91.0 3420
2735 76.9 189 269 91.3 3420
2935 82.4 189 269 91.7 3420
3265 90.1 186 264 92.3 3420
3465 94.6 184 261 92.6 3465
501-CB 2940 77.9 210 253 91.6 3500 0.09 1.5
3095 82.0 210 253 91.8
3250 86.0 210 253 92.1
3480 92.2 210 253 92.4

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

21
310 Nm 160-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.31 kgm2 1400 W 550 V 110-440 V 880 m3/h 980 Pa 275 kg 290 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
101-LC 605 19.6 63 310 73.8 1000 1.24 22.60
645 20.9 63 310 74.9 1000
680 22.1 63 310 75.9 1000
740 24.0 63 310 77.2 1000
835 26.6 62 305 79.2 1000
895 28.1 61 300 80.3 1000
101-KC 710 23.0 72 310 76.2 1175 0.97 17.30
750 24.4 72 310 77.1 1175
795 25.8 72 310 78.0 1175
860 27.9 72 310 79.2 1175
970 31.0 71 305 81.1 1175
1035 32.7 70 301 82.0 1175
101-HC 860 28.2 85 313 79.5 1330 0.68 12.70
910 29.8 85 313 80.4 1330
960 31.5 85 313 81.1 1330
1035 34.0 85 313 82.1 1330
1165 37.5 84 308 83.7 1330
1240 39.7 83 306 84.4 1330
101-GC 1060 34.7 102 313 82.3 1565 0.48 8.85
1120 36.6 102 313 83.0 1565
1180 38.7 102 313 83.6 1565
1270 41.6 102 313 84.5 1565
1425 45.9 100 308 85.8 1565
1515 48.3 99 304 86.4 1565
101-FC* 1360 44.4 127 312 85.1 2105 0.30 5.65
1435 46.9 127 312 85.7 2105
1510 49.4 127 312 86.2 2105
1625 53.1 127 312 86.9 2105
1815 58.4 125 307 88.0 2105
1930 61.6 124 305 88.5 2105
101-EB 1540 49.6 140 308 87.1 2350 0.25 4.60
1620 52.3 140 308 87.6 2350
1710 55.1 140 308 88.0 2350
1840 59.1 140 308 88.6 2350
2050 64.9 138 302 89.5 2350
2180 68.2 136 299 90.0 2350
101-EC* 1860 59.6 166 306 87.9 2815 0.18 3.20
1960 62.8 166 306 88.3 2815
2060 66.1 166 306 88.7 2815
2215 70.9 166 306 89.3 2815
2470 77.7 163 301 90.1 2815
2620 81.9 162 298 90.5 2815
101-CB* 2220 73.1 200 314 90.3 3230 0.11 2.30
2340 76.9 200 314 90.5 3230
2460 80.9 200 314 90.9 3230
2635 86.7 200 314 91.3 3230
2935 96.4 200 314 91.9 3230
3110 102.0 200 314 92.2 3230
101-BB* 2815 86.4 234 294 91.4 3500 0.08 1.50
2960 91.0 234 294 91.7 3500
3100 95.5 234 294 91.9 3500
3330 102.0 234 293 92.3 3500

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

22
350 Nm 160-4LO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.33 kgm2 1400 W 550 V 110-440 V 880 m3/h 980 Pa 280 kg 305 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
401-LC 620 23.2 72 357 77.7 990 0.95 19.6
660 24.6 72 357 78.6
695 26.0 72 357 79.5
755 28.2 72 357 80.6
850 31.2 71 350 82.0
910 32.9 70 346 82.9
401-KC 725 27.2 83 358 80.0 1130 0.73 15
770 28.9 83 358 80.7
815 30.5 83 358 81.2
880 32.9 83 358 82.2
990 36.3 81 351 83.8
1055 38.4 80 348 84.6
401-HC 870 32.9 97 361 82.4 1310 0.53 11
920 34.7 97 361 83.1
970 36.6 97 361 83.8
1045 39.5 97 361 84.7
1175 43.5 95 354 85.7
1250 45.9 94 350 86.4
401-GC 1070 39.9 115 357 84.8 1590 0.37 7.6
1130 42.2 115 357 85.4
1190 44.4 115 357 85.9
1280 47.8 115 357 86.7
1435 52.5 113 349 87.6
1530 55.3 112 346 88.2
401-GB 1180 41.9 120 340 85.7 1900 0.33 6.6
1250 44.3 120 340 86.2
1310 46.6 120 340 86.7
1410 50.1 120 340 87.4
1580 55.1 118 334 88.5
1680 58.0 117 330 89.0
401-FC 1370 51.3 144 357 87.5 1985 0.24 4.9
1450 54.1 144 357 87.9
1525 56.9 144 357 88.4
1635 61.1 144 357 89.0
1825 66.9 142 350 89.5
1940 70.3 140 346 89.9
401-EB 1550 55.0 154 339 88.0 2450 0.21 4.0
1640 58.1 154 339 88.5
1720 61.1 154 339 88.9
1850 65.6 154 339 89.4
2060 71.9 151 333 90.2
2190 75.5 150 329 90.7
401-EC1 1870 68.8 189 351 89.8 2690 0.14 2.8
1970 72.5 189 351 90.1
2075 76.2 189 351 90.5
2225 81.7 189 351 90.9
2475 89.2 186 344 91.3
2630 93.7 184 340 91.6
401-CB 2230 77.4 210 331 90.8 3480 0.1 2
2350 81.4 210 331 91.1
2465 85.5 210 331 91.4
2645 91.6 210 331 91.8
2940 100.1 207 325 92.3
3120 105.1 204 321 92.5
1
401-BB 2810 92.6 250 315 91.6 3500 0.07 1.3
2960 97.5 250 315 91.8
3105 102.3 250 315 92.1
3325 109.6 250 315 92.4

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

23
500 Nm 160-4LB
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.46 kgm2 2000 W 550 V 110-440 V 880 m3/h 980 Pa 380 kg 405 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 157... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
701-LC 410 21.8 72 508 72.2 715 1.21 29
435 23.2 72 508 73.4
460 24.6 72 508 74.4
500 26.7 72 508 75.8
570 29.9 71 500 78.2
615 31.7 70 494 79.4
701-KC 485 25.8 83 509 75.0 815 0.94 22.2
515 27.4 83 510 76.1
545 29.0 83 510 77.0
590 31.5 83 510 78.3
670 35.0 81 501 80.2
715 37.1 80 496 81.2
701-HC 585 31.4 97 514 78.2 945 0.69 16.3
620 33.3 97 514 79.0
655 35.2 97 514 79.9
705 38.0 97 514 81.0
800 42.2 95 505 82.6
850 44.6 94 500 83.5
701-GC 725 38.5 115 508 81.2 1145 0.47 11.3
765 40.7 115 508 81.9
810 43.0 115 508 82.6
870 46.3 115 508 83.6
985 51.3 113 499 85.1
1045 54.1 112 494 85.9
701-GB 800 40.6 120 487 82.2 1350 0.43 9.6
840 43.0 120 487 82.9
890 45.3 120 487 83.6
960 48.9 120 487 84.5
1070 53.9 118 479 85.8
1150 56.8 117 474 86.5
701-FC 935 49.9 144 509 84.5 1430 0.30 7.3
990 52.7 144 509 85.1
1045 55.5 144 509 85.7
1120 59.7 144 509 86.4
1255 65.8 142 500 87.6
1335 69.2 140 495 88.1
701-EB 1060 53.8 154 487 85.3 1750 0.27 5.8
1110 56.8 154 487 85.9
1170 59.8 154 487 86.4
1260 64.3 154 487 87.1
1410 70.7 151 478 88.2
1500 74.4 150 473 88.7
701-EC1 1290 67.4 189 500 87.6 1995 0.17 4.1
1360 71.1 189 500 88.0
1430 74.9 189 500 88.5
1535 80.4 189 500 89.0
1710 88.1 186 492 89.8
1820 92.6 184 486 90.3
1
701-CB 1540 76.4 210 473 89.3 2510 0.12 3
1625 80.5 210 473 89.7
1705 84.6 210 473 90.0
1830 90.7 210 473 90.5
2040 99.3 207 465 91.2
2165 104.3 204 460 91.5
2
701-BB 1945 91.7 250 450 90.4 2745 0.09 1.9
2050 96.6 250 450 90.7
2155 101.4 250 450 91.0
2310 108.7 250 450 91.4
2570 118.9 246 442 91.9
2725 124.8 243 437 92.2

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
2 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

24
400 Nm 180-4A
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.39 kgm2 1520 W 550 V 110-440 V 1300 m3/h 1250 Pa 290 kg 320 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
101-RC 650 27 85 400 77.9 2300 0.73 15.7
700 29 85 400 78.9
730 31 85 400 79.7
790 33 85 400 80.8
900 37 84 394 82.5
950 39 83 389 83.4
101-PC 750 32 97 406 80.2 1500 0.63 12.4
800 34 97 406 81.0
840 36 97 406 81.7
900 39 97 406 82.7
1020 43 95 399 84.2
1090 45 94 395 85.0
101-NC 880 37 111 407 82.4 2730 0.47 9.5
930 40 111 407 83.1
980 42 111 407 83.7
1060 45 111 407 84.6
1190 50 109 400 85.9
1260 52 108 396 86.6
101-LC 1040 43 126 396 84.0 3740 0.37 7
1100 46 126 396 84.6
1160 48 126 396 85.2
1250 52 126 396 86.0
1400 57 124 389 87.1
1490 60 123 385 87.8
101-HC 1280 53 152 398 86.0 3910 0.26 4.8
1350 56 152 398 86.5
1420 59 152 398 87.0
1530 64 152 398 87.7
1700 70 149 391 88.7
1810 81 148 387 89.2
101-GB 1400 59 166 400 87.2 2100 0.21 4.1
1480 62 166 400 87.6
1560 65 166 400 88.1
1680 70 166 400 88.7
1870 77 163 393 89.6
1990 94 162 389 90.0
101-FC* 1630 69 192 402 88.2 4500 0.16 3.1
1720 72 192 402 88.7
1810 76 192 402 89.1
1940 82 192 402 89.6
2170 90 189 395 90.4
2300 94 187 391 90.6
101-EB 1840 75 207 387 89.0 1950 0.13 2.5
1930 79 207 387 89.4 1950
2040 79 198 370 89.9 2040
2200 79 184 343 90.6 2200
2470 79 164 306 91.3 2470
2620 79 154 287 91.6 2620
101-DC1 2220 89 245 384 90.2 4500 0.1 1.7
2340 94 245 384 90.5
2460 99 245 384 90.8
2630 106 245 384 91.2
2930 116 241 377 91.9
3110 122 238 373 92.1
1
101-CB 2640 110 299 400 91.4 2660 0.06 1.3
2780 111 286 382 91.8 2780
2930 111 272 363 92.1 2930
3140 111 253 337 92.5 3140
3500 111 227 302 92.9 3500
3720 111 214 284 93.1 3720
1
101-BB 3330 137 368 393 92.4 3390 0.04 0.8
3500 139 356 380 92.6 3500
3690 139 338 361 92.9 3690
3950 139 315 335 93.2 3950
4400 139 283 300 93.5 4400

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

25
470 Nm 180-4B
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.47 kgm2 1670 W 550 V 110-440 V 1300 m3/h 1250 Pa 330 kg 360 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
201-RC 540 27 85 472 75.6 1800 0.81 18.7
570 28 85 472 76.6
600 30 85 472 77.5
660 32 85 472 78.8
740 36 84 464 80.7
790 38 83 459 81.7
201-PC 625 31 97 479 78.4 1200 0.69 14.8
660 33 97 479 79.3
700 35 97 479 80.1
755 38 97 479 81.2
855 42 95 471 82.9
910 44 94 466 83.8
201-NC 735 37 111 480 81.0 2360 0.52 11.3
775 39 111 480 81.8
820 41 111 480 82.5
885 44 111 480 83.4
995 49 109 472 84.9
1060 52 108 467 85.6
201-LC 875 43 126 467 82.8 3230 0.41 8.3
925 45 126 467 83.5
975 48 126 467 84.1
1050 51 126 467 85.0
1175 57 124 459 86.3
1255 60 123 454 86.9
201-HC 1075 53 152 469 85.1 3390 0.28 5.8
1135 56 152 469 85.7
1195 59 152 469 86.3
1285 63 152 469 87.0
1440 69 149 461 88.1
1530 73 148 456 88.6
201-GB 1175 58 166 471 86.1 1700 0.24 4.9
1245 61 166 471 86.7
1310 65 166 471 87.1
1410 70 166 471 87.8
1575 76 163 463 88.8
1675 80 162 458 89.3
201-FC* 1375 68 192 474 87.7 4200 0.17 3.7
1450 72 192 474 88.2
1530 76 192 474 88.6
1640 82 192 474 89.2
1830 89 189 456 90.0
1945 94 187 461 90.5
201-EB 1550 74 207 453 87.8 2500 0.15 3
1630 78 207 457 88.4
1710 82 207 457 88.8
1840 88 207 457 89.4
2050 96 204 449 90.1
2180 101 202 444 90.5
201-DC 1870 89 245 453 89.5 4500 0.11 2.1
1970 94 245 453 89.9
2070 98 245 453 90.2
2220 105 245 453 90.7
2475 115 241 445 91.4
2630 121 238 441 91.7
1
201-CB 2230 110 299 471 91.0 2300 0.07 1.5
2350 113 293 462 91.4 2350
2470 113 278 438 91.8 2470
2660 113 259 407 92.2 2660
2960 113 232 364 92.7 2960
3150 113 219 342 92.9 3150
1
201-BB 2810 136 368 464 92.0 2930 0.05 1
2960 142 365 460 92.2 2960
3110 142 346 436 92.6 3110
3340 142 322 405 92.9 3340
3720 141 289 363 93.2 3720
3950 141 273 341 93.4 3950
201-AB1 3800 168 450 424 93.0 4000 0.03 0.5

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

26
600 Nm 180-4C
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.55 kgm2 1900 W 550 V 110-440 V 1300 m3/h 1250 Pa 380 kg 410 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
301-PC 490 31 101 613 75.6 900 0.69 18.1
520 33 101 613 76.6
550 35 101 613 77.6
600 38 101 613 78.8
675 43 99 603 80.8
725 45 98 596 81.7
301-NC 575 38 117 621 78.2 1860 0.53 13.9
610 40 117 621 79.1
645 42 117 621 80.0
700 46 117 621 81.1
790 51 115 611 82.8
845 53 114 605 83.7
301-LC 690 44 132 601 80.5 2550 0.4 10.2
730 46 132 601 81.3
775 49 132 601 82.1
835 53 132 601 83.0
940 58 130 590 84.6
1000 61 128 584 85.3
301-HC 850 54 159 603 83.1 2690 0.28 7.1
900 57 159 603 83.8
950 60 159 603 84.4
1025 65 159 603 85.2
1150 71 156 593 86.5
1225 75 155 587 87.2
301-GB 940 60 174 607 84.6 1360 0.26 6
995 63 174 607 85.1
1050 67 174 607 85.7
1130 72 174 607 86.5
1265 79 171 597 87.6
1345 83 169 591 88.2
301-FC 1100 70 201 610 86.3 3330 0.19 4.5
1165 74 201 610 86.8
1225 78 201 610 87.3
1320 84 201 610 88.0
1475 93 198 599 89.0
1565 97 196 593 89.4
301-EB 1240 77 218 591 86.9 1330 0.17 3.6
1310 81 218 591 87.4 1330
1380 83 211 571 88.0 1380
1500 83 195 528 88.9 1500
1680 82 173 469 90.0 1680
1790 82 163 440 90.5 1790
1
301-DC * 1510 93 258 587 88.7 4500 0.12 2.5
1590 98 258 587 89.1
1670 103 258 587 89.5
1795 110 258 587 90.0
2000 121 254 576 90.7
2125 127 251 570 91.1
301-CB1 1795 115 315 610 90.1 1810 0.08 1.8
1900 116 301 583 90.6 1900
2000 116 286 553 91.0 2000
2150 115 266 513 91.6 2150
2400 115 238 458 92.2 2400
2550 115 224 431 92.4 2550
1
301-BB * 2270 142 386 598 91.3 2310 0.05 1.2
2395 144 372 576 91.6 2395
2520 144 354 547 92.0 2520
2710 144 329 508 92.4 2710
3020 144 295 454 92.9 3020
3200 143 278 427 93.0 3200
1
301-AB 3080 167 450 521 92.5 4000 0.03 0.7
3230 176 450 521 92.8
3400 185 450 521 92.9
3640 198 450 520 93.2

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

27
700 Nm 180-4D
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.69 kgm2 2240 W 550 V 110-440 V 1300 m3/h 1250 Pa 470 kg 500 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
401-NC 450 33 105 688 74.8 1500 0.77 17.1
480 35 105 688 75.8
510 37 105 688 76.8
550 40 105 688 78.0
625 44 103 676 80.0
670 47 102 670 81.0
401-LC 545 40 125 702 77.9 2210 0.55 12.6
580 43 125 702 78.8
610 45 125 702 79.6
660 49 125 702 80.7
745 54 123 690 82.5
800 57 122 683 83.3
401-HC 680 51 152 712 81.4 2310 0.37 8.7
720 54 152 712 82.1
760 57 152 712 82.8
820 61 152 712 83.7
920 68 149 700 85.2
980 71 148 693 85.9
401-GB 760 53 155 668 83.4 1100 0.3 7.4
800 56 155 668 84.0
845 59 155 668 84.6
910 64 155 668 85.5
1020 70 152 656 86.7
1085 74 151 649 87.3
401-FC 875 64 187 701 84.3 2930 0.24 5.6
925 68 187 701 84.9
975 72 187 701 85.5
1050 77 187 701 86.3
1180 85 184 688 87.4
1255 89 182 681 88.0
401-EB 1000 68 194 649 86.0 1300 0.19 4.5
1055 72 194 649 86.5 1300
1110 76 194 649 87.0 1300
1200 81 194 649 87.6 1300
1340 88 189 631 88.6 1340
1430 88 176 586 89.3 1430
401-DC* 1210 87 246 691 87.5 4500 0.14 3.1
1275 92 246 691 88.0
1340 97 246 691 88.4
1440 104 246 691 89.0
1610 114 242 679 89.8
1710 120 239 671 90.2
401-CB1 1445 101 280 669 89.3 1770 0.09 2.3
1525 107 280 669 89.7 1770
1605 112 280 669 90.0 1770
1720 121 280 669 90.5 1770
1925 124 257 614 91.3 1925
2045 123 242 576 91.6 2045
401-BB1* 1835 126 344 657 90.7 2250 0.06 1.5
1930 133 344 657 91.0 2250
2030 140 344 657 91.3 2250
2175 150 344 657 91.6 2250
2425 155 320 609 92.2 2425
2575 154 301 572 92.5 2575
1
401-AB 2470 166 450 644 91.8 4000 0.04 0.8
2600 175 450 644 92.0
2730 184 450 644 92.3
2930 197 450 643 92.5
3250 215 442 631 92.9
3450 225 438 625 93.1

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

28
800 Nm 180-4E
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3800 min-1 40 min-1 0.81 kgm2 2400 W 550 V 110-440 V 1500 m3/h 1530 Pa 520 kg 550 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T h n2 RA (115°C) LA (0Hz)


FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
501-HC 570 49 148 815 79.8 1700 0.42 10.3
605 51 148 815 80.6
635 54 148 815 81.3
690 59 148 815 82.3
775 65 146 801 83.9
825 69 144 792 84.6
501-GB 630 54 162 820 81.3 920 0.34 8.7
665 57 162 820 82.1
705 60 162 820 82.8
760 65 162 820 83.7
850 72 159 806 85.1
910 76 158 798 85.8
501-FC 735 62 181 795 83.0 2450 0.27 6.6
780 65 181 795 83.6
820 69 181 795 84.3
870 74 181 795 85.1
990 81 178 783 86.3
1055 86 176 775 87.0
501-EB 835 70 202 790 84.4 1070 0.22 5.3
885 74 202 790 85.0 1070
930 77 202 790 85.5 1070
1000 83 202 790 86.3 1070
1125 90 194 761 87.5 1125
1200 90 181 711 88.3 1200
501-DC 1020 84 239 789 86.5 3400 0.15 3.7
1075 89 239 789 87.0
1130 94 239 789 87.5
1215 100 239 789 88.1
1360 110 235 775 89.0
1445 116 233 766 89.5
501-CB1 1215 104 292 821 88.2 1450 0.11 2.7
1280 110 292 821 88.6 1450
1345 116 292 821 89.0 1450
1445 124 292 821 89.5 1450
1620 125 263 736 90.5 1620
1725 125 247 691 90.9 1725
1
501-BB 1545 130 358 805 89.8 3000 0.07 1.7
1625 137 358 805 90.1
1710 144 358 805 90.4
1835 154 358 805 90.9
2040 169 352 790 91.6
2170 177 348 781 91.9
1
501-AB 2100 166 450 757 91.4 3200 0.05 1
2200 175 450 756 91.7
2320 183 450 756 91.9
2480 196 450 756 92.2
2760 214 442 742 92.6

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

29
900-1000 Nm 180-4F
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3000 min-1 40 min-1 1.05 kgm2 2650 W 550 V 110-440 V 1900 m3/h 1400 Pa 630 kg 660 kg

Cat. Nr Ua (V):400 420 440 470 520 550 P I T 


h n2 RA (115°C) LA (0Hz)
FR 159... nb (min )
-1
(kW) (A) (Nm) (%) min -1
(Ω) (mH)
601-BF 610 66 194 1024 82.7 1200 0.26 10.5
650 69 194 1024 83.4
680 73 194 1024 84.0
740 79 194 1024 84.8
830 87 194 1007 86.1
880 92 189 996 86.8
601-FF 670 65 196 930 81.7 1050 0.29 8.5
710 69 196 930 82.4
750 73 196 930 83.0
810 79 196 930 83.9
910 87 193 914 85.3
970 86 191 904 86.0
601-EF 770 75 220 928 83.3 1200 0.22 6.8
810 79 220 928 83.9
860 83 220 927 84.5
920 90 220 927 85.3
1040 99 216 911 86.5
1100 104 214 902 87.1
601-BD 880 90 255 977 86.6 1800 0.14 5.6
930 95 255 977 87.1
980 100 255 977 87.6
1050 108 255 977 88.2
1170 118 251 960 89.1
1250 124 248 950 89.6
601-DF 890 86 249 918 84.7 1400 0.18 5.2
940 91 249 918 85.3
990 95 249 918 85.8
1070 103 249 918 86.5
1200 113 245 902 87.6
1270 119 242 892 88.1
601-CF 1060 103 294 929 86.5 1700 0.13 3.8
1120 109 294 929 87.0
1180 115 294 929 87.4
1270 123 294 929 88.0
1410 135 289 913 88.9
1500 142 286 903 89.4
1
601-AF * 1310 143 394 1039 89.7 2500 0.06 2.6
1380 151 394 1039 90.1
1450 158 394 1039 90.4
1560 170 394 1039 90.8
1740 186 387 1021 91.4
1840 195 383 1010 91.8
1
601-AD * 1850 175 474 905 91.4 2800 0.05 1.4
1940 184 474 905 91.7
2040 193 474 904 91.9
2190 207 474 904 92.2
2430 226 466 888 92.6
2580 237 461 878 92.8

1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.

* Normally kept in stock with reinforced impregnation.

Data subject to change without prior notice.

30
Dimension drawing, DMP 112-132 IC06

Dimensions in mm
DMP A AA AB AC AD AE AF AG AH AI AJ AK B BA BC BD BE BF
112-2MA 373 336 514
112-2LA 428 391 569
190 45 220 256 203 220 17 195 175 195 77 326 50 235 190
112-4M 373 336 514
112-4L 428 391 569

132-2M 220 17 195 175 195 77 482 419 335 590


132-4S 220 17 195 175 195 77 437 374 335 545
132-4M 216 47.5 260 295 223 220 17 195 175 195 77 366 482 50 419 335 590 190
132-4L 220 17 195 175 195 77 532 469 335 640
132-4LB 285 33.5 235 208 235 89 642 609 298 780

DMP C CA CB CC D DE E F GA H HA HC HD HE HF K KL L L+REO444R1 L+TDP0.2LT W (kg)


112-2MA 594.5 805.5 811.5 97
112-2LA 649.5 860.5 866.5 103
70 55 25 45 38 M10 80 10 41 112 10 241 451 66 250 12 60
112-4M 594.5 805.5 811.5 110
112-4L 649.5 860.5 866.5 117

132-2M 38 80 10 41 491 290 60 695.5 906.5 912.5 139


132-4S 38 80 10 41 491 290 60 650.5 861.5 867.5 122
132-4M 89 60 25 64 38 M10 80 10 41 132 12 261 491 86 290 12 60 695.5 906.5 912.5 152
132-4L 38 80 10 41 491 290 60 745.5 956.5 962.5 177
132-4LB 42 110 12 45 569 314 80 885 1096 1102 236

Dimensions are not binding

31
Dimension drawing, DMP 160-180 IC06

Dimensions in mm
DMP A AA AB AC AD AE AF AG AH AI AJ AK B BA BC BD BE BF
160-4S/SO 285 33.5 235 208 235 89 475 426 298 631
160-4M/MO 285 33.5 235 208 235 89 522 473 298 678
254 56 316 351 274 439 56 240
160-4L/LO 285 33.5 235 208 235 89 587 538 298 743
160-4LB 315 21.5 300 208 300 80 712 663.5 299 868

180-4A 66 294 355 25.5 265 95 561 66 499 305 718


180-4B 66 294 355 25.5 265 95 612 66 535 305 754
180-4C 66 294 355 25.5 265 95 677 66 616 305 835
180-4D
279 66
356 391 294 355 25.5
340 265
340 95
479 707 66 681 305 900
240
180-4E 61 294 405 28.5 270 105 720 66 741 349 960
180-4F 61 392 405 28.5 270 105 795 85 821 349 1071

DMP C CA CB CC D DE E F GA H HA HCHD HE HF K KL L L+REO444R1 L+TDP0.2LT W (kg)


160-4S/SO 611 356 744 955 961 206/216
160-4M/MO 611 356 791 1002 1008 246/256
108 65 28 80 48 M16 110 14 51.5 160 14 343.5 88.5 15 80
160-4L/LO 611 356 856 1067 1073 291/301
160-4LB 641 338 981 1192 1198 398

180-4A 195 50 55 M16 110 16 59 18 364 745 109 402 15 80 848.5 1059.5 1065.5 308
180-4B 195 35 55 M16 110 16 59 18 364 745 109 402 15 80 884.5 1095.5 1101.5 348
180-4C 195 21 60 M16 140 18 64 18 364 745 109 402 15 110 965.5 1176.5 1182.5 398
180-4D
121 195 43
91 70 M20 140 20 74.5
180 18 364 745 109 402 15 110 1030.5 1241.5 1247.5 488
180-4E 195 28 70 M20 140 20 74.5 18 364 815 109 448 15 110 1190.5 1301.5 1307.5 540
180-4F 95 40 70 M20 140 20 74.5 18 372.5 815 117.5 444 19 110 1248 1459 1465 650

Dimensions are not binding

32
Dimension drawing, DMP IC17/37

Dimensions in mm
DMP a b bb c cc d e oa ob oc t W (kg)
112-2MA 245 90
112-2LA 300 96
110 110 5 110 5 104 110 100 100 M6
112-4M 245 103
112-4L 300 110

132-2M 286 116.5 132


132-4S 241 116.5 115
132-4M 150 125 7.5 125 7.5 286 116.5 145 110 110 M6 145
132-4L 336 116.5 170
132-4LB 446 146.5 220

160-4S/MO 263 190/200


160-4M/MO 310 230/240
190 145 7.5 145 7.5 150 180 130 130 M6
160-4L/LO 375 275/285
160-4LB 500 380

180-4A 7.5 7.5 320 158.5 200 145 145 290


180-4B 7.5 7.5 356 158.5 200 145 145 330
180-4C 7.5 7.5 407 188.5 200 145 145 380
210 160 160 M8
180-4D 7.5 7.5 472 188.5 200 145 145 470
180-4E 7.5 7.5 532 188.5 200 145 145 520
180-4F 10 10 660 171 210 140 155 630

Dimensions are not binding

33
Dimension drawing, DMP IC666

Dimensions in mm
DMP A AA AB AC AD AE AF AK AL B BA BC BF BL BM BP BO C
132-2M 482 482 419 647 91 290 223
132-4S 437 437 374 647 91 290 223
132-4M 216 47.5 260 279 223 390 20 440 482
390 482 50 419 190 647 91 290 223 89
132-4L 532 532 469 647 91 290 223
132-4LB 642 642 609 772 121 400 238

160-4S/SO 515 527.5 475 426 723 753 325 240


160-4M/MO 515 527.5 522 473 723 800 325 240
254 56 316 335 274 20 616 56 240 115 240
108
160-4L/LO 515 527.5 587 538 723 865 325
160-4LB 606 597 712 663 843 990 320 278

180-4A 66 294 606 600 561 66 499 843 126.5 320 278
180-4B 66 294 606 600 612 66 535 843 126.5 320 278
180-4C 66 294 606 600 677 66 616 843 156.5 320 278
279 356 375 20 656 240 278
121
180-4D 66 294 606 600 707 66 681 843 156.5 320
180-4E 66 294 720 740 720 66 741 1047 149 500 337
180-4F 61 322 720 740 795 85 821 1047 131 500 337

DMP CA CB CC D DE E F GA H HA
HB HB HC HD HE K KL L W (kg)
132-2M 38 80 10 41 60 695.5 212
132-4S 38 80 10 41 60 650.5 205
132-4M 60 25 64 38 M10 80 10 41 132 12 215 261 1089 86 12 60 695.5 225
132-4L 38 80 10 41 60 745.5 250
132-4LB 42 110 12 45 80 885 310

160-4S/SO 215 215 1259 744 310


160-4M/MO 215 215 1259 791 340
65 28 80 48 M16 110 14 51.5 160 14 343.5 1259 88.5 15 80
160-4L/LO 215 215 856 385
160-4LB 240 240 1334 981 500

180-4A 195 50 55 M16 110 16 59 18 240 364 1356 109 15 80 848,5 525
180-4B 195 35 55 M16 110 16 59 18 240 364 1356 109 15 80 884,5 555
180-4C 195 21 60 M16 140 18 64 18 240 364 1356 109 15 110 965,5 615
91 180 18 240 364 1356 109 15
180-4D 195 43 70 M20 140 20 74.5 110 1030,5 645
180-4E 195 28 70 M20 140 20 74.5 18 280 364 1451 109 15 110 1090,5 725
180-4F 95 40 70 M20 140 20 74.5 16 280 372.5 1451 117.5 19 110 1248 820

Dimensions are not binding

34
Dimension drawing, DMP IC86W

Dimensions in mm
DMP A AA AB AC AD AE AK AM B BA BB BC BD BF BL BM BO C
132-2M 482 314 419 791 99
132-4S 437 314 374 746 99
132-4M 216 47.5 260 279 223 195 440 230 482 50 314 419 110 190 791 99 220 89
132-4L 532 314 469 841 99
132-4LB 642 344 609 951 129

160-4S/SO 475 426 753


160-4M/MO 522 473 800
254 56 316 335 274 240 616 278 56 393 110 240 158 215 108
160-4L/LO 587 538 865
160-4LB 712 663 990

180-4A 66 294 295 328 561 66 453.5 499 110 860 168.5 240
180-4B 66 294 295 328 612 66 453.5 535 110 896 168.5 240
180-4C 66 294 295 328 677 66 483.5 616 110 947 198.5 240
279 356 375 656 110
240 240
121
180-4D 66 294 295 328 707 66 483.5 681 1012 198.5
180-4E 66 294 292 337 720 66 542.5 741 142 1112 198.5 280
180-4F 61 322 292 337 795 85 525 821 142 1240 181 280

DMP CA CB CC D DE DN E F GA H HA HB HC HD HE K KL L W (kg)
132-2M 38 80 10 41 60 695.5 220
132-4S 38 80 10 41 60 650.5 200
132-4M 60 25 64 38 M10 20 80 10 41 132 12 599 261 719 86 12 60 695.5 235
132-4L 38 80 10 41 60 745.5 260
132-4LB 42 110 12 45 80 885.5 330

160-4S/SO 744 310


160-4M/MO 791 340
65 28 80 48 M16 20 110 14 51.5 160 14 723 343.5 819 88.5 15 80
160-4L/LO 856 400
160-4LB 981 500

180-4A 195 50 55 M16 20 110 16 59 18 761 364 857 109 15 80 848.5 410
180-4B 195 35 55 M16 20 110 16 59 18 761 364 857 109 15 80 884.5 460
180-4C 195 21 60 M16 20 140 18 64 18 761 364 857 109 15 110 965.5 510
91 180 18 761 364 857 109 15
180-4D 195 43 70 M20 20 140 20 74.5 110 1030.5 600
180-4E 195 28 70 M20 25 140 20 74.5 18 769 364 867 109 15 110 1090.5 660
180-4F 95 40 70 M20 25 140 20 74.5 16 769 372.5 867 117.5 19 110 1248 790

Dimensions are not binding

35
Dimension drawing, DMP Flanges

VIEW: 1 VIEW: 1B

VIEW: 2

Dimensions in mm

DMP Flange LA M Nj6 P S T View

112 F215 14 215 180 250 15 4 1B


F265 14 265 230 300 15 4 1B
132 F265 17 265 230 300 15 4 1B
F300 17 300 250 350 19 5 1B
160 F350 20 350 300 400 19 5 1B
180-4A/B/C/D/E F300 41 300 250 350 19 5 1
F350 17 350 300 400 19 5 1B
F400 17 400 350 450 19 5 2B
F500 20 500 450 550 19 5 2
180-4F F300 41 300 250 350 19 5 1
F500 20 500 450 550 19 5 2
Other dimensions on request

Dimension drawing, DMP tachometer flange

Dimensions are not binding

36
Ordering

Fan blower
The fan blower can be mounted slotted cover, a filter or a flange Pos 25-42:
on top or on either side, at the for an air-duct. Additional price for blower and
drive end or at the non-drive On request a pressure switch terminal box mounted on same
end. The location does not affect can be installed on the fan side.
the output of the motor (except blower and the terminal box
when specified in the tables). can be arranged in 42 different
The fan can be delivered with a mounting combinations.

38
Cat DMP 2002/05 E