DMP catalogue
1-200 kW, 5-1000 Nm
List of contents
Introduction ................................................................. p. 3
Options ....................................................................... p. 4
DM = DC motor
· Armature windings of var-
nished copper designed for
P = Motor type low commutating stresses
180 = Centre height in mm and high mechanical
4 = Number of poles strength.
E = Core length · Armature is impregnated to
ensure high degree of heat
transfer.
3
Options
Cooling forms
IC06 (IP23) Force ventilated o o o o o o
IC17 (IP23) Single pipe ventilated o o o o o o
IC37 (IP54) Double pipe ventilated o o o o o o
IC410 (IP54) Totally enclosed o o o o o o
IC416 (IP54) Totally enclosed, fan cooled o o o o o o
IC666 (IP54) Air-air cooled o o o o o
IC86W (IP54) Air-water cooled o o o o o
Other cooling forms available
Protection
IP55 o o o o o o
Mounting forms o o o o o o
IM1001 Horizontal foot o o o o o o
IM1002 Horizontal foot, two shaft ends o o o o o o
IM2001 Horizontal foot and flange o o o o o o
IM2011 Vertical foot and flange o o o o o o
Other mounting forms available
Pulse generators
POG 9 D (1-1250 ppr) o o o o o o
HG650 or DG60L (1024 ppr) o o o o o o
Others available
4
Application data
Blower position
Standard: On top of the motor at
the non-drive end.
Other positions on request.
Bearings
Grease lubricated ball bearings
as standard.
For belt drive please contact our
sales offices.
5
Application data
Bearings
Drive end Non-drive end
6
Output data
7
Output data
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
*excl. accessories
nb Base speed
Ua Armature voltage
P Mechanical power
I Armature current
T Torque
h Efficiency IEC
n2 Max electrical speed
RA Armature resistance
LA Armature inductance
8
30 Nm 112-2MA
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.03 kgm2 420 W 620 V 110-440 V 235 m3/h 375 Pa 90 kg 102 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
9
43 Nm 112-2LA
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.04 kgm2 500 W 620 V 110-440 V 235 m3/h 375 Pa 96 kg 108 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
10
47 Nm 112-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.037 kgm2 625 W 550 V 110-440 V 270 m3/h 480 Pa 103 kg 115 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
11
68 Nm 112-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.05 kgm2 740 W 550 V 110-440 V 270 m3/h 480 Pa 110 kg 122 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
12
65 Nm 132-2M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.09 kgm2 550 W 620 V 110-440 V 435 m3/h 400 Pa 132 kg 147 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
13
100 Nm 132-4S
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.10 kgm2 750 W 620 V 110-440 V 470 m3/h 550 Pa 115 kg 130 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
14
135 Nm 132-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.12 kgm2 830 W 620 V 110-440 V 470 m3/h 550 Pa 145 kg 160 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
15
150 Nm 132-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4000 min-1 40 min-1 0.14 kgm2 1000 W 620 V 110-440 V 470 m3/h 550 Pa 170 kg 185 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
16
240 Nm 132-4LB
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
5000 min-1 40 min-1 0.20 kgm2 1350 W 550 V 110-440 V 510 m3/h 810 Pa 220 kg 235 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
17
185 Nm 160-4S
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.22 kgm2 1050 W 550 V 110-440 V 880 m3/h 980 Pa 190 kg 215 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
18
210 Nm 160-4SO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.24 kgm2 1050 W 550 V 110-440 V 880 m3/h 980 Pa 200 kg 225 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
19
240 Nm 160-4M
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.25 kgm2 1250 W 550 V 110-440 V 880 m3/h 980 Pa 230 kg 245 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
20
270 Nm 160-4MO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.27 kgm2 1250 W 550 V 110-440 V 880 m3/h 980 Pa 230 kg 255 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
21
310 Nm 160-4L
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.31 kgm2 1400 W 550 V 110-440 V 880 m3/h 980 Pa 275 kg 290 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
22
350 Nm 160-4LO
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.33 kgm2 1400 W 550 V 110-440 V 880 m3/h 980 Pa 280 kg 305 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
23
500 Nm 160-4LB
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3500 min-1 40 min-1 0.46 kgm2 2000 W 550 V 110-440 V 880 m3/h 980 Pa 380 kg 405 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
2 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
24
400 Nm 180-4A
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.39 kgm2 1520 W 550 V 110-440 V 1300 m3/h 1250 Pa 290 kg 320 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
25
470 Nm 180-4B
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.47 kgm2 1670 W 550 V 110-440 V 1300 m3/h 1250 Pa 330 kg 360 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
26
600 Nm 180-4C
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.55 kgm2 1900 W 550 V 110-440 V 1300 m3/h 1250 Pa 380 kg 410 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
27
700 Nm 180-4D
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
4500 min-1 40 min-1 0.69 kgm2 2240 W 550 V 110-440 V 1300 m3/h 1250 Pa 470 kg 500 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 10% reduction of power.
28
800 Nm 180-4E
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3800 min-1 40 min-1 0.81 kgm2 2400 W 550 V 110-440 V 1500 m3/h 1530 Pa 520 kg 550 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
29
900-1000 Nm 180-4F
Technical data
nmax n0 J Pf Uamax Uf Vcool Pr W(foot) W(flange)
3000 min-1 40 min-1 1.05 kgm2 2650 W 550 V 110-440 V 1900 m3/h 1400 Pa 630 kg 660 kg
1 Cooling air inlet at commutator side. Can be used with cooling air inlet at shaft side with 15% reduction of power.
30
Dimension drawing, DMP 112-132 IC06
Dimensions in mm
DMP A AA AB AC AD AE AF AG AH AI AJ AK B BA BC BD BE BF
112-2MA 373 336 514
112-2LA 428 391 569
190 45 220 256 203 220 17 195 175 195 77 326 50 235 190
112-4M 373 336 514
112-4L 428 391 569
31
Dimension drawing, DMP 160-180 IC06
Dimensions in mm
DMP A AA AB AC AD AE AF AG AH AI AJ AK B BA BC BD BE BF
160-4S/SO 285 33.5 235 208 235 89 475 426 298 631
160-4M/MO 285 33.5 235 208 235 89 522 473 298 678
254 56 316 351 274 439 56 240
160-4L/LO 285 33.5 235 208 235 89 587 538 298 743
160-4LB 315 21.5 300 208 300 80 712 663.5 299 868
180-4A 195 50 55 M16 110 16 59 18 364 745 109 402 15 80 848.5 1059.5 1065.5 308
180-4B 195 35 55 M16 110 16 59 18 364 745 109 402 15 80 884.5 1095.5 1101.5 348
180-4C 195 21 60 M16 140 18 64 18 364 745 109 402 15 110 965.5 1176.5 1182.5 398
180-4D
121 195 43
91 70 M20 140 20 74.5
180 18 364 745 109 402 15 110 1030.5 1241.5 1247.5 488
180-4E 195 28 70 M20 140 20 74.5 18 364 815 109 448 15 110 1190.5 1301.5 1307.5 540
180-4F 95 40 70 M20 140 20 74.5 18 372.5 815 117.5 444 19 110 1248 1459 1465 650
32
Dimension drawing, DMP IC17/37
Dimensions in mm
DMP a b bb c cc d e oa ob oc t W (kg)
112-2MA 245 90
112-2LA 300 96
110 110 5 110 5 104 110 100 100 M6
112-4M 245 103
112-4L 300 110
33
Dimension drawing, DMP IC666
Dimensions in mm
DMP A AA AB AC AD AE AF AK AL B BA BC BF BL BM BP BO C
132-2M 482 482 419 647 91 290 223
132-4S 437 437 374 647 91 290 223
132-4M 216 47.5 260 279 223 390 20 440 482
390 482 50 419 190 647 91 290 223 89
132-4L 532 532 469 647 91 290 223
132-4LB 642 642 609 772 121 400 238
180-4A 66 294 606 600 561 66 499 843 126.5 320 278
180-4B 66 294 606 600 612 66 535 843 126.5 320 278
180-4C 66 294 606 600 677 66 616 843 156.5 320 278
279 356 375 20 656 240 278
121
180-4D 66 294 606 600 707 66 681 843 156.5 320
180-4E 66 294 720 740 720 66 741 1047 149 500 337
180-4F 61 322 720 740 795 85 821 1047 131 500 337
DMP CA CB CC D DE E F GA H HA
HB HB HC HD HE K KL L W (kg)
132-2M 38 80 10 41 60 695.5 212
132-4S 38 80 10 41 60 650.5 205
132-4M 60 25 64 38 M10 80 10 41 132 12 215 261 1089 86 12 60 695.5 225
132-4L 38 80 10 41 60 745.5 250
132-4LB 42 110 12 45 80 885 310
180-4A 195 50 55 M16 110 16 59 18 240 364 1356 109 15 80 848,5 525
180-4B 195 35 55 M16 110 16 59 18 240 364 1356 109 15 80 884,5 555
180-4C 195 21 60 M16 140 18 64 18 240 364 1356 109 15 110 965,5 615
91 180 18 240 364 1356 109 15
180-4D 195 43 70 M20 140 20 74.5 110 1030,5 645
180-4E 195 28 70 M20 140 20 74.5 18 280 364 1451 109 15 110 1090,5 725
180-4F 95 40 70 M20 140 20 74.5 16 280 372.5 1451 117.5 19 110 1248 820
34
Dimension drawing, DMP IC86W
Dimensions in mm
DMP A AA AB AC AD AE AK AM B BA BB BC BD BF BL BM BO C
132-2M 482 314 419 791 99
132-4S 437 314 374 746 99
132-4M 216 47.5 260 279 223 195 440 230 482 50 314 419 110 190 791 99 220 89
132-4L 532 314 469 841 99
132-4LB 642 344 609 951 129
180-4A 66 294 295 328 561 66 453.5 499 110 860 168.5 240
180-4B 66 294 295 328 612 66 453.5 535 110 896 168.5 240
180-4C 66 294 295 328 677 66 483.5 616 110 947 198.5 240
279 356 375 656 110
240 240
121
180-4D 66 294 295 328 707 66 483.5 681 1012 198.5
180-4E 66 294 292 337 720 66 542.5 741 142 1112 198.5 280
180-4F 61 322 292 337 795 85 525 821 142 1240 181 280
DMP CA CB CC D DE DN E F GA H HA HB HC HD HE K KL L W (kg)
132-2M 38 80 10 41 60 695.5 220
132-4S 38 80 10 41 60 650.5 200
132-4M 60 25 64 38 M10 20 80 10 41 132 12 599 261 719 86 12 60 695.5 235
132-4L 38 80 10 41 60 745.5 260
132-4LB 42 110 12 45 80 885.5 330
180-4A 195 50 55 M16 20 110 16 59 18 761 364 857 109 15 80 848.5 410
180-4B 195 35 55 M16 20 110 16 59 18 761 364 857 109 15 80 884.5 460
180-4C 195 21 60 M16 20 140 18 64 18 761 364 857 109 15 110 965.5 510
91 180 18 761 364 857 109 15
180-4D 195 43 70 M20 20 140 20 74.5 110 1030.5 600
180-4E 195 28 70 M20 25 140 20 74.5 18 769 364 867 109 15 110 1090.5 660
180-4F 95 40 70 M20 25 140 20 74.5 16 769 372.5 867 117.5 19 110 1248 790
35
Dimension drawing, DMP Flanges
VIEW: 1 VIEW: 1B
VIEW: 2
Dimensions in mm
36
Ordering
Fan blower
The fan blower can be mounted slotted cover, a filter or a flange Pos 25-42:
on top or on either side, at the for an air-duct. Additional price for blower and
drive end or at the non-drive On request a pressure switch terminal box mounted on same
end. The location does not affect can be installed on the fan side.
the output of the motor (except blower and the terminal box
when specified in the tables). can be arranged in 42 different
The fan can be delivered with a mounting combinations.
38
Cat DMP 2002/05 E