The Dräger Flame 2000 uses advanced flame analysis tools to quickly detect hydrocarbon-based fuel and gas
fires. With its capability of providing an early warning of flaming fires at 4.5 μm and immunity to false alarms
caused by other IR sources such as sunlight IR projectors – the Flame 2000 is the right choice for those who
want more performance for less.
The Flame 2000 is one of the most weather resistant single IR flame detector currently available on the market.
It comes with new features such as a heated window to eliminate icing and condensation, HART® capabilities
for digital, lower power requirements and a compact, lighter design.
Reliability
Functional safety is a concept applicable across all industry sectors. It is fundamental to enabling complex
technology used for safety-related systems. It provides assurance that the safety-related systems will offer
necessary risk reduction. The Flame 2000 is highly reliable and complies with the IEC 61508 Safety Integrity
Requirements of SIL2.
Automatic checks of the detector electronics and optics helps ensure that no fault goes undetected.
Additionally the test can be triggered manually at any time.
A tri-colored LED which is visible at the front of the detector provides a simple status indication to personnel in
close proximity to the detector. Green indicates normal operation; yellow indicates a fault and red indicates the
presence of radiation from a fire.
Installation is simple! The detector is easily installed with a stainless steel tilt mount which enables the detector
to be rotated up to 60° in all directions to position of the detector in relation to the potential fire source.
Benefits
System Components
Accessories
Flame Simulator
Weather Cover
Laser Pointer
Does the detector cover the area that needs protection? Is it located
correctly and does the detector’s cone of vision cover the most
dangerous spot? This accessory enables the installer to optimize
detector location and its actual detection area coverage.
D-5925-2016
Air Shield
Related Products
Related Products
Technical Data
Type Explosion proof IR flame detector for hydrocarbon- and hydrogen-based fires
Spectral Response IR = 4,4 – 4,6 μm
Measuring Performance Field of view Horizontal 90°; Vertical 90°
Response Time Typically 5 seconds
Sensitivity Ranges 2 Sensitive ranges for 1 ft2 (0.1 m2)
n-Heptane pan fire from 15 ft (5 m)
to 50 ft (15 m)
Detection Range Fuel ft / m
(at highest Sensitivity Setting n-Heptane / Gasoline 50 / 15
for 1 ft2 (0.1 m2) pan fire) Diesel Fuel / JP5 / Kerosene 37 / 11
Ethanol 95 % 25 / 7.5
Methanol 25 / 7.5
IPA (Isopropyl Alcohol) 25 / 7.5
Methane* 29.5 / 9
LPG* 43 / 13
Polypropylene Pellets 37 / 11
Office Paper 20 / 6
* 30" (0.75 m) high, 10" (0.25 m) width plume fire
Electrical Data
Output Signals 0 – 20 mA (stepped), HART®
Fault Signal 0 + 1 mA
BIT Fault Signal 2 mA ±10 %
Normal Signal 4 mA ±10 %
Warning Signal 16 mA ±5 %
Alarm Signal 20 mA ±5 %
Relays Alarm, Fault and Auxiliary
SPST volt-free contacts rated 2 A at 30 VDC
RS485 Modbus compatible communication link
Power supply 24 VDC nominal (18 – 32 VDC)
Power Consumption Standby: Max. 90 mA (110 mA with heated window)
Alarm: Max. 130 mA (160 mA with heated window)
Ambient Conditions
Temperature -55 to +75 °C / -67 to +167 °F (operating)
-55 to +85 °C / -67 to +185 °F (option and storage)
Humidity Up to 95 % non-condensing
(withstands up to 100 % RH for short periods)
Enclosure
Material Stainless steel SS 316
Material Option Heavy duty copper free aluminum, red epoxy enamel finish
Connecting Thread 2 × 3/4" – 14NPT or 2 × M25 × 1.5 mm
Weight Detector SS 316L 2.8 kg / aluminum 1.3 kg
Tilt mount 1.0 kg
Dimensions Detector 101.6 × 117 × 157 mm
Ingress Protection IP66 and IP67, NEMA 250 6P
Approvals
ATEX and IECEx Ex II 2 G D
Ex d e IIC T5 Gb Ex d e IIC T4 Gb Ex d e mb IIC T4 Gb
Ex tb IIIC T96°C Db Ex tb IIIC T106°C Db Ex tb IIIC T98°C Db
(-55 °C ≤ Ta ≤ +75 °C) (-55 °C ≤ Ta ≤ +85 °C) (Ta = -55 °C to +75 °C)
08 | Dräger Flame 2000
Technical Data
Ordering Information
Dräger Flame 2000 (R-111SC) 68 13 919
Dräger Flame 2000 (R-211SC) 68 13 920
Dräger Flame 2000 (R-311SC) 68 13 921
Dräger Flame 2000 (R-211AC) 68 13 941
Dräger Flame 2000 (R-311AC) 68 13 942
Accessories
Flame Simulator FS-1300 (IR) 68 13 975
Dräger Flame 2xx0 Air Shield 68 13 977
Dräger Flame 2xx0 Duct Mount 68 13 978
Tilt Mount Flame Detector 68 13 979
Weather cover Flame Detector (SS) 68 13 189
Weather cover Flame Detector (ABS) 68 13 190
Dräger Flame 2xx0 Laser Pointer 68 13 890
Dräger Flame Pole Mount 3" 68 13 323
Dräger Flame Pole Mount 2" 68 13 322
Dräger Flame USB RS-485 Kit 68 13 994
Battery Pack for Flame Simulator FS1x00 68 13 889
HART® is a registered trademark of the HART® Communication Foundation
CORPORATE HEADQUARTERS REGION DACH REGION MIDDLE EAST, AFRICA REGION CENTRAL
Drägerwerk AG & Co. KGaA Dräger Safety AG & Co. KGaA Dräger Safety AG & Co. KGaA AND SOUTH AMERICA
Moislinger Allee 53–55 Revalstraße 1 Branch Office Dräger Panama S. de R.L.
23558 Lübeck, Germany 23560 Lübeck, Germany P.O. Box 505108 Complejo Business Park,
www.draeger.com Tel +49 451 882 0 Dubai, United Arab Emirates V tower, 10th floor
Fax +49 451 882 2080 Tel +971 4 4294 600 Panama City
info@draeger.com Fax +971 4 4294 699 Tel +507 377 9100
. contactuae@draeger.com Fax +507 377 9130
REGION EUROPE . contactcsa@draeger.com
Dräger Safety AG & Co. KGaA REGION ASIA PACIFIC .
Revalstraße 1 Draeger Safety Asia Pte Ltd REGION NORTH AMERICA
23560 Lübeck, Germany 25 International Business Park Draeger, Inc.
Tel +49 451 882 0 #04-20/21 German Centre 3135 Quarry Road
Fax +49 451 882 2080 Singapore 609916 Telford, PA 18969
info@draeger.com Tel +65 6308 9400 Tel +1 800 4DRAGER
. Fax +65 6308 9401 (+1 800 437 2437)
asia.pacific@draeger.com Fax +1 215 723 5935
. info.usa@draeger.com
.
Locate your Regional Sales
Representative at:
www.draeger.com/contact