Cat 6 UTP PVC Cable Belden 7965E: Construction

This document summarizes the specifications of a Cat 6 UTP PVC cable made by Belden called the 7965E. It has 4 twisted pairs of 23 AWG solid bare copper conductors with polyolefin insulation. The cable sheath is made of flame retardant PVC. It is designed to support Cat 6 and Cat 5e applications like Ethernet and meets various standards like ISO/IEC 11801. Key electrical characteristics include attenuation below specification limits, NEXT and power sum NEXT above minimum levels, and return loss above minimum levels according to Cat 6 specifications.

Uploaded by

NishathFarviz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views2 pages

Cat 6 UTP PVC Cable Belden 7965E: Construction

This document summarizes the specifications of a Cat 6 UTP PVC cable made by Belden called the 7965E. It has 4 twisted pairs of 23 AWG solid bare copper conductors with polyolefin insulation. The cable sheath is made of flame retardant PVC. It is designed to support Cat 6 and Cat 5e applications like Ethernet and meets various standards like ISO/IEC 11801. Key electrical characteristics include attenuation below specification limits, NEXT and power sum NEXT above minimum levels, and return loss above minimum levels according to Cat 6 specifications.

Uploaded by

NishathFarviz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Cat 6 UTP PVC Cable

Belden 7965E
Construction
Conductor 23 awg solid bare copper (0.57mm)
Insulation Polyolefine
Pair 4 twisted pairs: white/blue & blue, white/orange & orange, white/green & green,
white/brown & brown Conductor identification according to IEC 60304
Diameter over insulation 1.01mm
Cross web FRNC compound
Sheath Flame retardant PVC, grey
Overall diameter: 6.20mm

BATT Part Number 54248

Applications
Horizontal & building backbone cable to support cat 6 and cat 5e applications, such
as 10 Base-T, 100 Base-T, 1000 Base-T, FDDI, ATM

Standards
ISO/IEC 11801 2nd edition (2002), EN 50173 2nd edition (2001), ANSI/TIA/EIA
568-b.2 (2002)

General Characteristics
Temperature range - operation -200C to +600C
Temperature range - installation 00C to +500C
Minimum bending radius - operation 25 mm
Minimum bending radius - installation 50mm
Maxiumum pulling tension 80N
Flame retardancy IEC 60332
Caloric value 490 kJ/m
Weight 43.9 kg/km
Maximum operating voltage 48 V rms
Max continuous current per conductor (250C) 1.4 A

Electrical Characteristics at 200C


Nominal mutual capacitance at 1kHz 50 nF/km
Max conductor DCR 70 Ohm/km
Nominal Velocity of Propagation 0.7 c
Mean characteristic impedance 4-100 MHz* 100 +/- 5 Ohms
SKEW - propagation delay difference (100MHz) typical ≤ 15 ns/100m

* according to cable requirements of ISO/IEC 11801 category 6, sept 2002

www.batt.co.uk
[email protected]
Cat 6 UTP PVC Cable
Belden 7965E
Electrical Characteristics at 200C (cont)
Attenuation
Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Max)* dB/100m - 4.0 6.0 7.6 8.5 10.8 15.5 19.9 25.3 29.2 33
Typical dB/100m (1.7) 3.5 5.6 7.1 8.0 10.1 14.4 18.6 23.6 27.0 30.7

NEXT Near end crosstalk


Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 66 60 57 56 53 48 45 42 41 39


Typical dB/100m (76) 73 66 64 63 56 55 52 49 48 45

Power sum NEXT


Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 63 57 54 53 50 45 42 39 38 36


Typical dB/100m (74) 71 64 62 61 54 53 50 47 46 43

Power sum ELFEXT


Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 53 45 41 39 35 29 25 21 19 17


Typical dB/100m (70) 64 57 51 49 45 39 35 31 29 27

ACR
Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 62.0 54.0 49.4 47.5 42.2 32.5 25.1 16.7 11.8 6.0
Typical dB/100m (74) 70 60 57 55 46 41 33 25 21 14

Power sum ACR


Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 59.0 51.0 46.4 44.5 39.2 29.5 22.1 13.7 8.8 3.0
Typical dB/100m (72) 68 58 55 53 44 39 31 23 19 12

Return Loss
Frequency MHz 1 4 10 16 20 31.2 62.5 100 155 200 250

Spec (Min)* dB/100m - 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.8 18.0 17.3
Typical dB/100m (33) 36 44 42 40 38 36 31 27 25 24
* specification values according to cable requirements of ISO/IEC 11801 category 6, Sept 2002
Note: values between brackets are for information only
Aberdeen: 01224 897979 Leeds: 0113 253 3565 Germany: +49 6131 6273874

Birmingham: 0121 313 2870 Manchester: 01204 793111 Italy: +39 02 8965 6318

Bristol: 0117 966 6333 Peterborough: 01733 558485 Netherlands: +31 186 622311

Cardiff: 02920 450044 Teesside: 01642 678633 Singapore: +65 6515 9348

Edinburgh: 0131 333 4400 Belgium: +32 15 20 65 72 Houston: +1 713 590 1100

Erith: 01322 441165 Denmark: +45 3965 6650

You might also like