Catalogo Kappler 2016
Catalogo Kappler 2016
Catalogo Kappler 2016
NOTE: Zytron 500 style Z5HTN C2 and certain Medical styles use specific sizing
(XS, SM, MD, LG, XL, 2X ,3X, 4X and 5X). Please contact customer service for details.
APRIL 2016
Kappler, Inc.
P.O. Box 490
Shipping: 55 Grimes Drive
Guntersville, Alabama 35976
Toll Free: 800.600.4019
Local: 256.505.4005 Visit us on the web
Fax: 256.505.4151
email: [email protected]
Table of Contents confidence. We sell you the suit, but we give you the data
to ensure a safe decision.
NFPA Overview.....................................................25
Technical Data......................................................26
Relax.
It takes a lot of confidence to put your behind the technology that makes the
brand on a gas-tight suit. It’s a promise of protection possible in the first place.
protection we don’t take lightly. But from
For forty years Kappler has defined an
chemical-flash garments to biohazard
entire industry with patented technology
coveralls, we’re the first to tell you:
and proven garment designs. And we’ve
It’s not just the suit. built a reputation for quality, innovation
It’s knowing it’s the right suit, made and straightforward advice on what
from the right fabric, with the right to wear. Today more than ever, the
seam. With test data that confirms Kappler brand on your protective
all of the above. It’s also knowing garment means you always know
something about the people what you’re getting into.
2
Made In The USA – And Worn All Over The World.
From fabric development to packing the box, quality is an integral component to every Kappler garment.
Registered to ISO 9001 since 1996, we document every detail when it comes to ensuring product quality.
End-user safety is job one, and our integrated manufacturing process is geared to making sure every garment
meets demanding specifications. Whether it’s designing the most user-friendly suit possible or pressure-testing
every gas-tight suit before it leaves the plant, Kappler quality comes through every time. From Berry-compliant
products for DoD markets to NFPA-certifed apparel for the most challenging hazmat calls, you know what
you’re getting into with Kappler.
Select a fabric.
Find a fabric proven against
your hazard – a complete
list of chemicals tested
can be found on the
HazMatch app or online
at hazmatch.com. BIOHAZARD
PROTECTION
2 Serged Bound
Produced when three Produced with two
Choose the seam. threads are interlocked pieces of fabric joined
around the edges of by a piece of binding,
The right seam ensures your two pieces of fabric. then stitched through
garment is constructed to For particulates plus all layers. For
match your specific hazard. residual liquids to light particulates plus
splash where no skin residual liquids to
hazard is involved. light splash where skin hazard is involved,
and moderate splash for non skin hazards.
4
HazMatch®. The app is
free, the data priceless.
HazMatch® is our easy-to-use selection tool that helps
you make informed decisions about protective apparel.
Search by chemicalor by fabric, and save results to meet
OSHA Hazard Assessment requirements. Download the
free app or use it online at hazmatch.com – it’s fast, easy,
free, and only from Kappler.
ProVent ProVent
7000 10,000
Proven Microporous
Technology – From
Biohazard Scenarios
To General Hazards.
• Patented ProVent 10,000 fabric passes
both ASTM F1670 blood penetration
and ASTM F1671 viral penetration tests.
6
ProVent®
New Guidelines from
OSHA and the CDC
OSHA and the CDC have issued a comprehensive
PPE guidance document for workers who may be
exposed to potentially infected blood and body
fluids. Details include:
• The guidance is in a matrix format and identifies Shown above are typical
the type and level of PPE performance. garment types for this fabric.
View standard styles at
• It includes protective gowns and coveralls, kappler.com and see page 28
described as fluid resistant or impermeable. for custom options.
Skid-resistant attached
Spherical Bacteria ≥ ~0.5 uM boots enhance worker
safety.
Phi-X174 ~0.027 uM
HIV ~0.10 uM
EBOLA ~0.08 uM
HCV ~0.042 uM
Zytron Zytron
100 100XP
8
Zytron® 100/100XP
Zytron 100 and 100XP
Specific Chemicals Tested*
Minutes
Chemical
100 100XP
1,2-Dihydroxyethane >480 >480
Aqua Fortis NT >480 Shown above are typical
garment types for this fabric.
Battery Acid >480 >480 View standard styles at
Black Liquor >480 >480 kappler.com and see page 28
for custom options.
Caustic Soda >480 >480
Chromic Acid >480 >480
Ethylene Glycol >480 >480 Hooded coverall
Formaldehyde >480 NT styles feature
extended neck
Glutaric Dialdehyde >480 >480
design.
Gluteraldehyde >480 >480
Green Liquor >480 NT
Zytron 100XP
Hydrofluoric Acid 48% >480 >480 offers enhanced
Hydrogen Peroxide >480 NT fabric strength.
Methylene Oxide >480 NT
Nitric Acid NT >480
Orthophosphoric Acid NT >480
Phosphoric Acid NT >480 ChemTape® is an
Potassium Cyanide >480 NT essential accessory
Sodium Chloride Oxide >480 NT
for most chemical
scenarios – see page
Sodium Hydroxide >480 >480
22 for details.
Sodium Hypochlorite >480 NT
Sulfuric Acid >480 >480
White Liquor >480 NT
* Industrial chemical testing was conducted in accordance
with ASTM F 739 with normalized breakthrough times
reported in minutes. For detailed technical data and Both Zytron 100 and 100XP
physical properties see page 26 or visit kappler.com.
hold out many common
industrial hazards.
Zytron 200
10
Zytron® 200
Zytron 200
Specific Chemicals Tested*
Chemical Minutes
Acetic Acid >480
Acetonitrile 52
Acrylonitrile 65 Shown above are typical
garment types for this fabric.
Aniline >480 View standard styles at
Battery Acid >480 kappler.com and see page 28
for custom options.
Benzene 36
Caustic Soda >480
Chlorobenzene 38 Extended neck design on
Crude Oil >480 hooded coverall styles
Dimethyl Sulfate >480 adds protection.
Ethanol >480
Fuel Oil LS >480
Hydrofluoric Acid 48% >480
Hydrogen Peroxide >480
Heat-sealed/taped
Jet Fuel A >480
garments (shown) come
Methanol >480 with a double storm
Methyl Acetate 330 flap, and bound seam
Methyl Bromide 59 garments come with
a single storm flap.
N,N-Dimethylformamide 77
Nitric Acid >480
Nitrobenzene 97
Phenol @43 C 287
Potassium Hydroxide >480
Sodium Hydroxide >480
Sodium Hypochlorite >480
Sulfuric Acid >480
Trifluoroacetic Acid >480
* Industrial chemical testing was conducted in accordance
with ASTM F 739 with normalized breakthrough times
reported in minutes. For detailed technical data and
physical properties see page 26 or visit kappler.com.
Tingley HazProof ®
boots are available
from Kappler as an
authorized distributor.
Zytron 300
12
Zytron® 300
Zytron 300
ASTM F1001 Chemical Test Battery*
Chemical Minutes**
Acetone >480
Acetonitrile 87
Shown above are typical
Carbon Disulfide >480 garment types for this fabric.
Dichloromethane 70 View standard styles at
kappler.com and see page 28
Diethylamine >480 for custom options.
Dimethylformamide >480
Ethyl Acetate >480
Large face shield
n - Hexane >480
on encapsulating
Methyl Alcohol 55 suits for better
Nitrobenzene >480 field of vision.
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene >480
Tetrahydrofuran >480
Toluene >480
Gases
Ammonia Gas 39 Attached gloves
1,3 Butadiene Gas >480 are available on
Chlorine Gas >480 any heat sealed/
Ethylene Oxide Gas 81 taped suit style.
Hydrogen Chloride Gas >480
Methyl Chloride Gas >480
Zytron 400
14
Zytron® 400
Zytron 400
ASTM F1001 Chemical Test Battery*
Chemical Minutes
Acetone >480
Acetonitrile >480 Shown above are typical
Carbon Disulfide >480 garment types for this fabric.
View standard styles at
Dichloromethane 88 kappler.com and see page 28
Diethylamine >480 for custom options.
Dimethylformamide >480
Tough fabric with
Ethyl Acetate >480
excellent physical
n - Hexane >480 properties for
Methyl Alcohol >480 demanding work
Nitrobenzene >480 applications.
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene >480
Tetrahydrofuran >480
Toluene >480
Gases
Ammonia Gas NT
1,3 Butadiene Gas NT
Chlorine Gas NT
Ethylene Oxide Gas 305
Hydrogen Chloride Gas NT
Attached gloves
Methyl Chloride Gas NT
are an available
* Industrial chemical testing was conducted in accordance custom option.
with ASTM F 739 with normalized breakthrough times
reported in minutes. For detailed technical data and
physical properties see page 26 or visit kappler.com.
Zytron 500
16
Zytron® 500
Zytron 500
ASTM F1001 Chemical Test Battery*
Chemical Minutes
Acetone >480
Acetonitrile >480
Shown above are typical
Carbon Disulfide >480 garment types for this fabric.
View standard styles at
Dichloromethane >480
kappler.com and see page 28
Diethylamine >480 for custom options.
Dimethylformamide >480
Ethyl Acetate >480 Large-view face
n - Hexane >480 shield allows better
Methyl Alcohol >480 field of vision.
Nitrobenzene >480
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene >480
Tetrahydrofuran >480
Toluene >480
Gases
Ammonia Gas >480
1,3 Butadiene Gas >480
Chlorine Gas >480 All Hazmat styles
Ethylene Oxide Gas >480 include 2N1® Glove
Hydrogen Chloride Gas >480 System with barrier
Methyl Chloride Gas >480
liner gloves.
Frontline 300
Splash-And-Flash
Protection For
Petrochemical
Environments.
• Three-way protection for chemical,
flash-fire and radiant heat.
18
Frontline® 300
Frontline 300
ASTM F1001 Chemical Test Battery*
Chemical Minutes
Acetone >480
Acetonitrile >480 Shown above are typical
garment types for this fabric.
Carbon Disulfide >480 View standard styles at
Dichloromethane 10 kappler.com and see page 28
for custom options.
Diethylamine >480
Dimethylformamide >480
Ethyl Acetate >480 Coverall styles feature
special hood design
n - Hexane >480
for better fit against
Methyl Alcohol >480 respirator.
Nitrobenzene >480
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene >480
Tetrahydrofuran >480
Toluene >480
Gases
Ammonia Gas >480
1,3 Butadiene Gas >480
Chlorine Gas >480
Ethylene Oxide Gas >480
Other Chemicals Tested
Benzene >480 Frontline 300 offers
true “splash-and-flash”
Diesel Fuel >480
protection, plus excellent
Diethylethanolamine >480 radiant heat protection.
Gasoline >480
Hydrofluoric acid (48%) >480
Kerosene >480
Methanol >480
* Industrial chemical testing was conducted in accordance Reinforced knee area for
with ASTM F 739 with normalized breakthrough times added confidence and
reported in minutes. For detailed technical data and work flexibility.
physical properties see page 26 or visit kappler.com.
Frontline 500
20
Frontline® 500
Frontline 500
ASTM F1001 Chemical Test Battery*
Chemical Minutes
Acetone >480
Acetonitrile >480
Shown above are typical
Carbon Disulfide >480 garment types for this fabric.
View standard styles at
Dichloromethane 253 kappler.com and see page 28
for custom options.
Diethylamine >480
Dimethylformamide >480
Ethyl Acetate >480 Wide-view face
n - Hexane >480 shield allows
expanded field
Methyl Alcohol >480
of vision.
Nitrobenzene >480
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene >480
Tetrahydrofuran >480
Toluene >480
Gases
Ammonia Gas >480
1,3 Butadiene Gas >480
Chlorine Gas >480
Removable Kevlar
Ethylene Oxide Gas >480 outer glove, plus
Hydrogen Chloride Gas >480 field-replaceable
2N1® Glove System
Methyl Chloride Gas >480
which prevents inner
glove inversion when
Chemical Warfare Agent Data** removing hands.
Chemical Agent Minutes Criteria
Bis (2-chloroethyl) sulfide
(Mustard:HD) >480 4.0 ug/cm2
48” gas-tight PVC
Isopropyl methylfluorophosphonate zipper facilitates
>480 1.25 ug/cm2
(Sarin:GB) easier donning
Chlorovinyl
See page 28 arsinedichloride
for complete technical>240
data and
4.0 ug/cm2 and doffing.
(Lewisite:L)
physical properties.
O-ethyl S-(2-diisopropylaminoethyl)
>480 1.25 ug/cm2
methylphosphonothiolate (Nerve:VX)
* Industrial chemical testing was conducted in accordance
with ASTM F 739 with normalized breakthrough times
reported in minutes. **Chemical Warfare Agent testing was
conducted in accordance with MIL-STD-282 and/or NFPA
1994-2001 with breakthrough times reported based on
total cumulative permeation. For detailed technical data
and physical properties see page 26 or visit kappler.com. Frontline garments are designed
for chemical flash-fire protection
FOR ESCAPE ONLY in the event of
a chemical flash fire.
Responder ID Kit
Large, easy-to-read identification
numbers enhance safety where
worker identities are obscured. Accessory and specialty products continue
through page 24. For a complete list of
Self-adhesive, easy to apply, Kappler accessories or additional details
complete set includes call customer service at 1-800-600-4019.
numbers 0-9. 24 sets per case.
Style 99415.
22
Kappler’s Digital Pressure
Test Kit Is Flexible, Easy To
Use And Extremely Accurate.
Kappler’s automated Digital Pressure Test Kit improves
the efficiency and accuracy of gas-tight garment tests
for both ASTM and CE methods. Our unique design
features a digital readout for more accurate testing,
while a large LCD touchscreen allows easy test
criteria selection and data input. All fittings and hoses
are included – the user simply provides a Grade D air
supply with a 1/4 inch NPT fitting. Press START and the
test is performed automatically, allowing the user to
handle other duties while the test is in process. For easy
and accurate record-keeping, test data can be copied to
the provided USB stick via the built-in USB port.
USB port allows easy
connection to a data Style AKMOC.
storage device.
A video of the test procedure and data formatting program can be
Large, easy-to-read touch-
found online at kappler.com/resources under “Training Videos.”
screen for selecting test
criteria and data input.
Cooling Vest
The Kappler Cooling Vest with patented
Phase Change Material is lightweight
and provides hours of cooling. Available
Male Glove in two cooling-capacity sizes, in mesh or
Decon Shower
Kappler’s patented Decontamination
Shower is made with Zytron 500 fabric
to ensure hazardous material run-off is
safely contained. The removable spray
wand with adjustable shut-off valve and
ergo-grip handle allow better water For a complete list of Kappler
accessories or additional details call
control during decon. Simple design customer service at 1-800-600-4019.
and snap-lock components mean easy
setup and take-down. Catch Basin w/
frame and shower wand, Style Z5HD0.
Shower curtain and frame, Style Z5HD1.
24
NFPA
Standards Overview
Scope Hazmat Response Vapor Hazmat Response Liquid Chem/Bio Terrorism Chem/Bio Terrorism Chem/Bio Terrorism Incident
Incident Response Vapor Incident Response Liquid Response Particle
Chemical vs Garment Fabric, Permeation resistance 1 hr vs 21 Penetration resistance Permeation resistance Permeation resistance Not Required
Seams, Visors, Gloves, Boots industrial chemicals, 4 toxic 1 hr vs 7 industrial 1 hr vs 5 toxic industrial 1 hr vs 5 toxic industrial
industrial chemicals and chemicals chemical and mustard chemicals and mustard
warfare agents soman and soman and soman
and mustard
Challenge Level 100 % concentration 100 % concentration Liquids 10 g/m2 Liquids 10 g/m2 Not Required
and full contact and full contact Gases 350 ppm Gases 40 ppm
100 g/m2 agents Closed Top Cell Open Top Cell
Breakthrough Criteria ASTM F 739 Cumulative 6.0 TICs, ASTM F 903 Visual liquid ASTM F739 Cumulative ASTM F 739 Cumulative Not Required
4.0 mustard, 1.25 soman 6.0 TICs, 4.0 mustard, 6.0 TICs, 4.0 mustard,
1.25 soman 1.25 soman
Whole Garment ASTM F 1052 Pressure Test ASTM F 1359 MIST PDDF >360 MIST PDDF >120 Particle Inward Leakage
MIST inward leakage Shower Test > 20 min ASTM F 1359 ASTM F 1359 Test < 5%
ASTM F 1359 Shower Test > 60 min Shower Test > 20 min Shower Test >4 min
Flashfire Option 7 second flash propane
Flame Resistance Pass Not Required Not Required Not Required Not Required
ASTM F 1358
COMFORT ASTM F 1868 Not Required Not Required Not Required Pass Pass
Total Heat Loss
Viral Resistance ASTM F 1671 Not Required Not Required Pass Pass Pass
FABRIC/ SEAMS
Components Boots/SCBA Boots/Respirator Boots/SCBA Boots/Specify Respirator Boots/Specify Respirator
Kappler Products Frontline® 500 - F5H580-91, Zytron® 300 - Z3H426-92, Zytron® 500 - Z5HTN-C2
F5H580-9C, F5H580-9Z Z3H427-92, Z3H428-92
Z3H437-92, Z3H576-92
Z3H577-92, Z3H579-92
* Changes are in the process for NFPA standards 1991, 1992 and 1994. New edition NFPA 1991 has been issued effective January 2016. Standards 1992
and 1994 are currently in revision cycle and are scheduled for issue in January 2018.
* Industrial chemical testing was conducted in accordance with ASTM F 739 with normalized breakthrough times reported in minutes.
** C
hemical Warfare Agent testing was conducted in accordance with MIL-STD-282 and/or NFPA 1994-2001 with breakthrough times reported based on
total cumulative permeation.
Note: Sources for all chemical test data are independent laboratories. All tests were performed under laboratory conditions and not under
actual use conditions. Tests were performed on material samples, not actual garments.
Kappler, Know What You’re Getting Into, ProVent, Zytron, Frontline, ChemTape, HazMatch, 2N1, and ChemScan are trademarks of Kappler, Inc.
Responder, Reflector, Pro/Shield, NexGen, SuitSmart and CPF are trademarks of E. I. du Pont de Nemours and Company. HazProof is a trademark of Tingley Rubber.
26
Typical Physical Properties Zytron® Frontline®
TEST METHOD 100 100XP 200 300 400 500 300 500
Grab Tensile Strength MD* ASTM D751(lbs/N) 32 / 142 49 / 217 52 / 231 78 / 347 155 / 689 120/ 534 134 / 596 137 / 609.38
Grab Tensile Strength CD* ASTM D751(lbs/N) 24 / 106 38 / 169 39 / 173 69 / 307 152 / 676 121 / 538 125 / 556 166 / 738.37
Tear Resistance Trapezoid MD*(lbs/N) method details below** 11.5 / 51 17.4 / 77 22.9 / 101.8 16.6 / 74 42.2 / 188 35 / 156 13.7 / 60.94 13.5 / 60.05
Tear Resistance Trapezoid CD*(lbs/N) method details below** 7.4 / 32 10.3 / 45 9.6 / 42.7 22.1 / 98 50.6 / 225 37 / 168 10.7 / 44.79 14 / 62.27
Ball Burst ASTM D3787 (lbs/N) 28 / 124 46 / 204 43 / 191 58 / 258 153 / 681 128 / 569 123 / 547.10 134 / 596.03
Flammability Resistance ASTM F1358 N/A N/A N/A N/A N/A N/A PASS PASS
*MD - Machine Direction, CD - Cross Direction
**ASTM D1117 (Zytron 100, 200) ASTM D5587 (Zytron 300, 400, 500) ASTM D571 (Frontline 300, 500)
WARNING: This information is based on technical data that Kappler believes to be reliable. It is subject to revision as additional knowledge and experience are
gained. The website will contain Kappler’s most up-to-date product information, and customers who receive pamphlets, brochures or other literature should
be aware that such “hard copy” information may not be as current as the information on Kappler’s website. Customers also should recognize that there are uses,
environments and chemicals for which Kappler products, garments and/or fabrics are unsuitable. It is the responsibility of the user to review available data and
verify that the product, garment and/or fabric is appropriate for the intended use and meets all specified government and/or industry standards. Also, the cus-
tomer should review all available information on the website to understand the uses – and limitations – on ALL products, garments and fabrics which Kappler
makes available. CAUTION: Do not use for fire protection. Avoid open flame or intense heat.
28
Precision
When there’s no room for
Decision
Choose With Confidence
guesswork, Kappler delivers the
data and support you need.
Whether you’re responding to a hazmat call or specifying
apparel for a routine bid, Kappler helps you choose with
Table of Contents confidence. We sell you the suit, but we give you the data
to ensure a safe decision.
NFPA Overview.....................................................25
Technical Data......................................................26
NOTE: Zytron 500 style Z5HTN C2 and certain Medical styles use specific sizing
(XS, SM, MD, LG, XL, 2X ,3X, 4X and 5X). Please contact customer service for details.
APRIL 2016
Kappler, Inc.
P.O. Box 490
Shipping: 55 Grimes Drive
Guntersville, Alabama 35976
Toll Free: 800.600.4019
Local: 256.505.4005 Visit us on the web
Fax: 256.505.4151
email: [email protected]