The document summarizes the specifications and features of the MXL R144 Ribbon Microphone. It is a bidirectional ribbon microphone with a figure-8 polar pattern and a frequency response of 20Hz-17kHz. It has a ribbon element made of 1.8-micron aluminum and requires a preamp with an input impedance over 1500 ohms. The microphone does not require power but using phantom power can damage the ribbon element. Care should be taken to avoid damage to the fragile ribbon.

Uploaded by

aragon1974
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views2 pages

R144 Manual

The document summarizes the specifications and features of the MXL R144 Ribbon Microphone. It is a bidirectional ribbon microphone with a figure-8 polar pattern and a frequency response of 20Hz-17kHz. It has a ribbon element made of 1.8-micron aluminum and requires a preamp with an input impedance over 1500 ohms. The microphone does not require power but using phantom power can damage the ribbon element. Care should be taken to avoid damage to the fragile ribbon.

Uploaded by

aragon1974
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

R144

A Division of Marshall Electronics


Phone: 310-333-0606 • 800-800-6608 • Fax: 310-333-0688
www.mxlmics.com • [email protected]
Ribbon Microphone
R144
Ribbon Microphone
Specifications
Type Ribbon Velocity Microphone
Ribbon Element 1.8-micron aluminum ribbon
Thank you for choosing the MXL R144 Ribbon Microphone. For best results, please take a few
moments to read this manual and familiarize yourself with proper operation and care of this
Ribbon Length 47 mm
microphone. Frequency Response 20Hz -17kHz
Polar Pattern Figure 8
Contents
Unpack your MXL R144 Microphone package carefully and verify that all of the following items are Impedance 250 ohms
included: Sensitivity -56 dB (0 dB=1V/Pa)
• MXL Ribbon Microphone Rated Load Impedance >1500 Ohms
• Shock Mount Max SPL for 0.5% THD >130 dB @1 kHz
• Microfiber Cleaning Cloth Size 47mm x 171mm/1.85 in. x 6.75 in.
If any of these items are missing or damaged, contact the company from which you purchased the Weight 400g/0.85 lbs
microphone. Metal Finish Purple and chrome
General Characteristics Frequency Chart Polar Pattern
The MXL R144 Ribbon microphone uses an aluminum ribbon transducer which by nature is a 0
bidirectional (figure-8) pickup pattern. A figure-8 pattern will pick up sounds from the front and
back sides of the microphone with equal sensitivity while maintaining a large amount of rejection
90° off access. The front of the microphone is indicated by the MXL logo where the audio signal
270 90
is “in-phase” while the back side has an inverted phase. Ribbon mics typically have a lower
output than condenser microphones and may require a preamplifier with a lot of gain. It is highly
recommended to use a preamp with low noise, high gain, and an input impedance of 1500 ohms
or greater. We strongly advise experimentation with placement and isolation requirements with the
180
gain initially set low to avoid possible equipment (and hearing) damage.
Care
Power Requirements The ribbon element is very fragile. Although each unit has been thoroughly checked by MXL, it is
IMPORTANT! This microphone does NOT require a power supply. Use of phantom power with important to check the microphone as soon as you receive it to insure that it was not damaged
this microphone is NOT recommended as it can severely damage the ribbon element and cause in shipping. To help prevent transducer failure, avoid large vibrations and severe shock such
the microphone to be unusable. as dropping the microphone. Never expose the microphone to large bursts of air as it can
stretch or tear the ribbon element. It is highly recommended to use a pop-filter when using this
Microphone Cable microphone. Dust and foreign material (especially metal shavings) can degrade the performance
of a microphone so always store the unit in its case. Never intentionally or accidentally apply
The microphone cable can have a profound effect on the sound of any microphone. Even the finest power to the microphone as it can permanently damage the ribbon element. Please note: Damage
microphone will sound poor if the interconnect cable allows noise to enter or causes distortion and to the ribbon is not covered by the warranty, and there will be a charge for a replacement.
loss of information. We recommend that you use the best microphone cable that your budget
will allow.
Warranty
Shock Mount MXL microphones are guaranteed against defects in materials and workmanship for one year from
The MXL shock mount can shift in shipment. Simply shift the nylon bands to center the microphone the date of purchase. If you encounter any problem with this unit, promptly contact the company
in the assembly. Be sure that the wire clamp does not rest on the chassis of the mount, as this from which you purchased it for assistance. The original dated sales receipt will be necessary
impairs mechanical isolation. Slide the mount all the way to the rim of the microphone for the most for any warranty claim. Do not send any unit directly to us without prior authorization from our
secure hold. service department. Warranty coverage is limited to repair or replacement (at our option) of the
microphone, and does not cover incidental damages due to use of this unit, nor damage caused