LC1D65AP7: Product Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Product data sheet LC1D65AP7

Characteristics TeSys D contactor - 3P(3 NO) - AC-3 - <= 440


V 65 A - 230 V AC coil

Main
Range of product TeSys D
Product or component Contactor
type
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-3
Poles description 3P
Power pole contact 3 NO
composition
[Ue] rated operational <= 690 V AC 25...400 Hz for power circuit
voltage <= 690 V DC for power circuit

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
[Ie] rated operational 80 A (<= 60 °C) at <= 440 V AC AC-1 for power
current circuit
65 A (<= 60 °C) at <= 440 V AC AC-3 for power
circuit
Motor power kW 18.5 kW at 220...230 V AC 50/60 Hz
30 kW at 380...400 V AC 50/60 Hz
37 kW at 500 V AC 50/60 Hz
37 kW at 660...690 V AC 50/60 Hz

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Motor power HP 40 hp at 460/480 V AC 50/60 Hz for 3 phases
(according to UL / CSA) motors

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
5 hp at 115 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases
motors
20 hp at 230/240 V AC 50/60 Hz for 3 phases
motors
50 hp at 575/600 V AC 50/60 Hz for 3 phases
motors
Control circuit type AC 50/60 Hz
Control circuit voltage 230 V AC 50/60 Hz
Auxiliary contact 1 NO + 1 NC
composition
[Uimp] rated impulse 6 kV conforming to IEC 60947
withstand voltage
Overvoltage category III
[Ith] conventional free 10 A at <= 60 °C for signalling circuit
air thermal current 80 A at <= 60 °C for power circuit
Irms rated making 140 A AC for signalling circuit conforming to IEC
capacity 60947-5-1
250 A DC for signalling circuit conforming to IEC
60947-5-1
1000 A at 440 V for power circuit conforming to IEC
60947
Rated breaking 1000 A at 440 V for power circuit conforming to IEC
capacity 60947
[Icw] rated short-time 100 A 1 s signalling circuit
withstand current 120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
520 A <= 40 °C 10 s power circuit
900 A <= 40 °C 1 s power circuit
110 A <= 40 °C 10 min power circuit
260 A <= 40 °C 1 min power circuit

19/8/2011
1
Associated fuse rating 10 A gG for signalling circuit conforming to IEC
60947-5-1
125 A gG at <= 690 V coordination type 1 for power
circuit
125 A gG at <= 690 V coordination type 2 for power
circuit
Average impedance 1.5 mOhm at 50 Hz - Ith 80 A for power circuit
[Ui] rated insulation 690 V for power circuit conforming to IEC 60947-4-1
voltage 600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for signalling circuit conforming to IEC
60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Power dissipation per 9.6 W AC-1
pole 6.3 W AC-3
Safety cover With
Mounting support Plate
Rail
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 n°14
Product certifications CCC
CSA
GOST
UL
Connections - terminals Power circuit: EverLink BTR screw connectors 1
cable(s) 1...35 mm² - cable stiffness: flexible - without
cable end
Power circuit: EverLink BTR screw connectors 2
cable(s) 1...25 mm² - cable stiffness: flexible - without
cable end
Power circuit: EverLink BTR screw connectors 1
cable(s) 1...35 mm² - cable stiffness: flexible - with
cable end
Power circuit: EverLink BTR screw connectors 2
cable(s) 1...25 mm² - cable stiffness: flexible - with
cable end
Power circuit: EverLink BTR screw connectors 1
cable(s) 1...35 mm² - cable stiffness: solid - without
cable end
Power circuit: EverLink BTR screw connectors 2
cable(s) 1...25 mm² - cable stiffness: solid - without
cable end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable(s)
1...2.5 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm² - cable stiffness: solid - without cable end
Tightening torque Power circuit: 5 N.m - on EverLink BTR screw
connectors - cable <= 25 mm² hexagonal 4 mm
Power circuit: 8 N.m - on EverLink BTR screw
connectors - cable 25...35 mm² hexagonal 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals -
with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals -
with screwdriver Philips No 2
Operating time 4...19 ms opening
12...26 ms closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load
conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical
load conforming to EN/ISO 13849-1

2
Mechanical durability 6 Mcycles
(millions)
Operating rate 3600 cyc/h at <= 60 °C

Complementary
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz
0.8...1.1 Uc at 60 °C operational 50 Hz
0.85...1.1 Uc at 60 °C operational 60 Hz
Inrush power in VA 140 VA at 20 °C (cos φ 0.75) 60 Hz
160 VA at 20 °C (cos φ 0.75) 50 Hz
Hold-in power consumption in VA 13 VA at 20 °C (cos φ 0.3) 60 Hz
15 VA at 20 °C (cos φ 0.3) 50 Hz
Heat dissipation 4...5 W at 50/60 Hz
Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance > 10 MOhm for signalling circuit

Environment
IP degree of protection IP2x front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -60...80 °C
Permissible ambient air temperature around the -40...70 °C at Uc
device
Operating altitude 3000 m without derating in temperature
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
Vibrations contactor closed 4 Gn, 5...300 Hz
Shocks contactor open 10 Gn for 11 ms
Shocks contactor closed 15 Gn for 11 ms
Height 122 mm
Width 55 mm
Depth 120 mm
Product weight 0.86 kg

You might also like