160722021623
160722021623
160722021623
OF
METHANOL
H81FED - COURSEWORK II
Group 30
Name Student ID
Saw Meng Kiat UNIMKL- 023927
Isabelle Tay Sui Kim UNIMKL- 023322
Vera Tanzil UNIMKL- 023932
Rachel Hu Jia Yun UNIMKL- 014842
1
Table of content
Section I
Brief literature search on equipment Pages
1.1 Auto-thermal Reformer (Isabelle Tay) 3-7
1.2 Fire Heater (Saw Meng Kiat) 8-12
1.3 Let-down Vessel (Vera Tanzil) 13-17
1.4 Distillation Column (Rachel Hu) 18
Section II
Engineering AutoCAD Drawing
2.1 Autothermal Reformer (Isabelle Tay) 19-20
2.2 Fire Heater (Saw Meng Kiat) 21-23
2.3 Let Down Vessel (Vera Tanzil) 24
2.4 Distillation Column (Rachel Hu) 25
Section III
Environmental protection and process safety
3.1 Bow Tie Diagram 26
3.2 Bow Tie Diagram Description 27-30
Section IV
Extended Summary
4.1 Extended Summary by Saw Meng Kiat 31
4.2 Extended Summary by Isabelle Tay 32
4.3 Extended Summary by Vera Tanzil 33
4.4 Extended Summary by Rachel Hu 34
Section V
References
5.1 Combined references 35-38
Section VI
Appendix
6.1 Material Safety Data Sheet (Methane) 39-43
6.2 Emergency Response Plan 44-45
6.3 Emergency Evacuation Plan 46
6.4 Plant Operation Accident Investigation 47-48
Form
2
1.1 Brief Literature Review on Autothermal Reformer
Introduction:
3
Cross-Section of ATR and Table of Comparison for Reformers (Sandia National
Laboratories, 2007)
4
Schematic cross section of an ATR reactor vessel (Steven F. Rice and David P.
Mann, 2007)
Pressure Shell
Outer Diameter (Top Length of Top Section: Width:
Section): 3.96m 6.12m 0.27m
Outer Diameter Length of Bottom Section: Material Used:
(Bottom Section): 6.71m Steel
4.87m
Justification:
Steel was chosen as the material for the pressure shell as it has high
thermal conductivity. The width used is 0.27m, it is not too thick as there
will be multi refractory layers within the shell.
Refractory Lining
1 Layer: Foil-backed
st
2nd Layer: Calcium 3rd Layer: Heat
Bubble Pack Silicate Brick Insulating Brick
Justification:
The foil-backed bubble pack was chosen, as its reflective surface will
prevent heat loss transferring from the syngas in the outlet stream to the
surrounding surfaces. It is also flexible, so it can easily encase the pipe
carrying syngas. (Ecofoil.com, 2015) Calcium silicate brick was chosen as
it has high thermal resistance and stability. It is non-combustible and
non-corrosive, so it can be placed near the burner and combustion
chamber. It is also re-usable and has long life, so maintenance costs can
be reduced. (Jrrefractory.com, 2015) Light-weight heat insulating bricks
are chosen as the final layer for the refractory lining. The purpose of this
layer is to prevent heat transferring to the pressure shell. The composition
of this brick is Alumina:Silica:Ferric Oxide = 37:61:2. It is soft and light,
and can be easily cut to fit the shape of the pressure shell and to
compliment the shapes of the previous two layer. Air is the best insulation
for the refractory, and this particular insulating contains many tiny air
spaces shaped like a honeycomb. (Traditionaloven.com, 2015) (Refractory
Engineering - Materials - Design - Construction, 2005)
5
Burner & Combustion Chamber
Burner: CTS Burner Shape of Combustion Chamber:
Conical
Justification:
CTS Burner was chosen because of its burning characteristics, such as its
centered flame and efficient mixing at the burner nozzles. These
characteristics allow a soot free combustion, which reduces soot deposit
onto the catalyst, prolonging the lifetime of the catalyst. The efficient
mixing also allows homogenous temperature and gas distribution from the
combustion chamber at the top to the bottom of the catalyst bed. (Dahl et
al., 2015) The combustion chamber (recirculation chamber) is conically
shaped. This is in order to protect both the refractory and the burner from
the hot flame core and gas at the combustion section. (Steynburg and
Dry, 2004)
Catalyst
1st Type: Topsoe 2nd Type: Topsoe Shape of Catalyst Pellet:
RKS-2-7H RKS-2P-7H with seven axial holes
Justification:
Both catalysts are nickel based catalyst which are favourable for the
synthesis of methanol. The 2P-7H catalyst has lower nickel content, it has
lower reforming activity and will retard deposition of foreign matter onto
the catalyst. The 2P-7H will be loaded onto the 2-7H catalyst (as shown in
equipment design). Both these catalyst have magnesium alumina spinel
carrier, which has high thermal ability, as the spinel has higher melting
point and a generally higher thermal strength and stability than alumina
based catalyst. This is necessary as the catalyst bed will be under very
high temperature (850 °C) The shape of the catalyst pellet is shaped
optimized with seven axial holes. This is to increase it surface area to
provide a higher catalyst activity as well to induce low catalyst pressure
drop. (Haldor Topsoe A/S, 2015)
Operating Conditions
Pressure: 100 bar Temperature in the Minimal Volume
Combustion Chamber: Required:
850 °C 2.715 m3
Calculations:
Pressure = 100 bar = 98.6923 atm
Total no. of moles/hour = 2909.51163 moles/hour
Gas Constant, R= 0.082 atm*L/mole*K
Temperature = 1123 K
PV=nRT:
V=nRT/P = (2909.51163 moles/hour) (0.082 atm*L/mole*K) (1123 K)
/ (98.6923 atm)
= 2715 L
= 2.715m3
6
Other Features (Manholes)
Diameter of the manholes: 2.16m Number of manholes: 2
Justification:
The manholes are designed wide enough so that technicians can enter the
reformer during maintenance. This also makes it easier for the catalyst
beds to be changed. In case of emergencies while technicians are in the
reformer, the multiple manholes allow them to evacuate more efficiently.
Proper verification of the installation site has to be done in order to ensure that
the site is able to withstand the weight of the equipment. Before anyone
operates or performs maintenance on the ATR, they should understand the basic
functions of every component of the system, as every component has their
distinct function; some are for basic operations and control, whereas others are
safety devices that shut the system down automatically in order to prevent
damage and personal injury. The ATR has layers of safety checks that are
designed to protect both the operators and the equipment itself from harm. If a
particular safety device is not functioning, other safety checks will still be in
place to back them up. A major safety measure is the flame monitor. If the
flame at the burner is not present, the valves will prevent incoming flow of the
feedstock.
(Industrial Heating, 2015)
7
1.2 Brief Literature Review on Fire Heaters
A fire heater is a direct-fired heat exchanger which uses the combustion of fuels
to increase the process fluid temperature. These process fluid flow through the
coils and tubes which are aligned or mounted throughout the heater. Once the
desired temperature is achieved, the fluids will then proceed to the next reaction
stage such as auto thermal reforming. By using this type of heater, the
operation can be made continuous and the foam formation can also be reduced.
All types of fire heaters have some features in common. For example, they are
built with two different heating zones or sections, which are radiant zones and
convection zones. Shield or stack zone is another zone which serves as a
separator between radiant and convection zones. (Corporation, 2015)
In the vertical cylindrical fire heater, the radiation section has a cylinder shape
with a vertical axis, which means the radiant tubes are arranged vertically in a
circle. Besides, burners are usually positioned at the bottom floor of the heater.
The heat exchange area covers the vertical walls and therefore shows circular
symmetry with respect to the heating assembly. However, the shield and
convection tubes are normally horizontal. (Fired process heaters, n.d.)
Better process control and design (Cylindrical type heater can reduce
the residence time towards the process outlet and it is very beneficial to
critical services.
Cost saving design
Cylindrical type heater can be a dependable and cost effective design by
minimizing the plot surface and material cost. Vertical tube designs with
top-mounted convection typically requires smaller construction area
Minimum number of burners used
With combustion-air pre heat, these cylindrical design can be tailored to
reduce the number of burners used.
8
Design Justification of Fire Heater
Radiant Section
1. The vertical radiant tubes are situated along the cylindrical walls in the
radiant part of the heater and they get radiant heat straight from the
burners.
2. Most of the heat released in the heater (50-65%) are delivered to the
process fluid primarily by direct radiation from the hot flame gas.
3. The refractory lining in the radiant section is the most expensive
component of the heater and normally 85% of the radiant heat must be
obtained from here.
4. Very important for thermal analysis and design of fire heater.
5. The bridge wall temperature has a range of 800-1000 °C.
6. The radiant tubes are installed with minimum spacing from refractory.
Convection section
1. Instead of hitting the radiant section directly, the process fluid will
normally enter the coil inlet in the convection section where it is pre
heated before moving into the radiant tubes for further heating. The
convection section eradicate heat from the flue gas to preheat the
contents of the convection tubes and notably reduce the temperature of
the flue gas leaving the stack.
2. The process fluid receive about 25-35% of the total heat released in this
section and some are lost due to flue gas exiting the stack.
3. Inside the radiant and convection section, tube temperature is measured
and monitored regularly.
Shield Section
1. When flue gas flows from the convection section and before reaching the
stack, it will pass by one section which is the breeching section. Most of
the heat should be recuperated and the temperature should be reduced
when the flue gas reaches the stack.
9
2. A stack has a cylindrical structure which brings flue gas to the surrounding
atmosphere and deliver necessary draft.
3. Draft is the pressure of flue gas which is always negative when measured
at any point in the heater. This literature review focuses more on natural
draft heater, which means no fan or air blower is required to move the
combustion air into the heater. All the actions are carried out by the stack
alone including the removal of flue gas from the heater.
4. The flue gas temperature as it leaves the convection section is known as
stack temperature.
Component Function
10
Operating Conditions
For ideal operation, excess oxygen in the flue gas entering the convection
section is reduced and there is a slight negative pressure at the convection
section inlet.
However, for most of the heater design, thermal efficiency is the most significant
operating factor. This is especially true in view of existing trend of rising fuel
price and environmental issues.
Secondary
Air register Refractory CO 2
Gas
Premix Water Vapour
Chamber
Oxygen
NOx
Primary
Air register
PPM Combustibles
Burner
Tip
Nitrogen
The function of the burner is to pre-mix the fuel with the primary air that is
aspirated into the burner through the flowing of flue gas. Without removing the
flame off the burner, the air should be flowing at its maximum rate. Besides, due
to the fact that low gas pressure is able to reduce the optimum performance of
fire heater, the pressure of the fuel gas supplied to the burner must be properly
maintained. Most of the air (primary air) is transferred to the burner together
with the fuel gas. On top of that, secondary air is also introduced into the burner
and adjusted with the registers. Excess or too little secondary air can contribute
to poor combustion. (AMETEK, Inc., 2015)
There are 2 main supplies of heat input to the radiant section which are the
combustion heat of fuel, Qcofuel and the sensible heat of air combustion, Qair and
fuel combustion, Qfuel. Radiant tubes, QR and shield tubes, Qshield captivate some
of the heat input in the radiant section. The residual heat is then carried by the
flue gas which is leaving the radiant section, Qfluegases or lost due to radiation on
the heater walls, Qlosses. The heat loss is dependent on the size of the heater and
therefore, the smaller the heater, the greater the heat losses. Below is the given
equation for heat balance. (Fired process heaters, n.d.)
Qcofuel + Qair + Qfuel = QR + Qshield + Qfluegases + Qlosses
The overall thermal efficiency of the fire heater is reliant on the efficiency of the
heat recovery from the flue gases, which in turn depends on the dimension of
the heat exchange surface area in fire heater. In order to expand the heat
transfer area and therefore further boost the overall efficiency of the heater,
studded or finned tubes are usually used in the convection section.
11
Fire Heater Design Considerations
12
1.3 Brief Literature Review on Let down Vessel
[Vera Tanzil-023932]
For industrial purposes now and then there is a need to separate a vapour-liquid
mixture. This is where let-down vessel, which is also commonly known as knock-
out drum (vessel) or vapour-liquid separator, is brought to play. This equipment
is used to decelerate gases, allowing liquid to “fall out” of the gas stream with
the help of gravity (Alliedflare.com, n.d.). At the bottom of the vessel is where
the liquid will accumulate and withdrawn. Entrainment of any liquid droplets in
the vapour is diminished by the vapour travelling at a designed velocity (See,
n.d.).
(Source : http://www.jmcampbell.com/tip-of-the-month/2014/12/troubleshooting-gas-liquid-
separators-removal-of-liquids-from-the-gas/)
13
Below here are the summary of the components found in the equipment.
Components Explanation
Primary separation section (inlet) The main function is to separate
liquid from gas. Rapid elimination of
bulky liquid and liquid slugs from the
gas stream, vice versa, is desired.
Inlet diffuser Mixed phase inlet stream is
divided into a series of lateral
flowing streams
(Digitalrefining.com, 2015)
Secondary separation section In this section, gravity settling helps
(Gas gravity separation setion) in the removal of smaller liquid in this
section of the equipment. Reducing
gas turmoil and decreased gas
velocity play an important role.
Liquid separation section This is where the liquid accumulates
(Liquid gravity separation section) and is also where gas bubbles which
are trapped within the liquid are
being removed.
Wire mesh/ eliminator Also known as mist extractor or
demister pad
14
Provides efficient removal (up
to 99% removal of droplets 3
micron and larger) and low
pressure drop due to a great
number of hurdles diverting
entrapped droplets in a flowing
vapour.
(Demisterpads.com, 2015)
Vortex breaker Averts troubleshooting of potential
pump suction especially when there is
a need to remove the accumulated
liquid.
Specifications
Settling velocity:
U1 = 0.07[(ρL-ρv)/ ρv]1/2
15
The calculated U1 based on mass balance from coursework 1 is 0.364 m/s
Dv = √(4Vv/ πUs)
The final calculated Dv based on the related mass balance from previous
assignment is ≈ 0.9 m. The finalized height of the vessel is 1.5m by taking
safety and also possible increase in future production into considerations.
Volume of the vessel is determined by using the ideal gas law formula:
PV = nRT
V = volume, L
T = absolute temperature, K
Calculation:
PV = nRT
Therefore, V = nRT/P
V = (100)(8.3145)(321)/100000
V = 2.67 m3
16
Specifications of the inlet diffuser
The inlet feed in this system is a mixture of liquid and gas, thus prone to corrosion
complications, therefore stainless steel inlet diffuser is preferred. Moreover, inlet
diffuser is able work well at higher pressure, despite that it is generally designed
at dynamic pressures of <8000 Pa.
As the wire mesh pad will also come in contact with liquid (also containing water),
stainless steel is one of the main materials in order to prevent hassles due to
corrosion (i.e. frequent replacement of the wire mesh pad).
17
1.4 Brief Literature Review on Distillation Column
Key Features
Sieve trays
Sieve tray is chosen because it is cheaper than other type of trays and
need low maintenance. Sieve tray is a punctured plate with holes of 0.5
inches diameter on it. Multi orifices effect will occur as the vapour comes
out from the holes and the vapour flowed through the tray to make
contact with the liquid is controlled by the number of holes on the tray.
The liquid is transported down the distillation column by the down-comers
which is an overflow device and dam on the side of the plate.
Condenser
A stainless steel shell and tube heat exchanger is used to condense the
vapour from the top of the distillation column. The coolant used in the
heat exchanger is water.
Reboiler
Reboiler is used to produce boil-up vapour in the distillation column. It is
covered with insulator and the main heating element will be stainless
steel.
The main material used to build the distillation column will be stainless
steel due to the slight corrosive nature of methanol. [b]
Equipment Specification
The height of the distillation column will be 120 feet tall with the diameter of 12
feet. The distillation column has 69 sieve trays with about 1.5 feet distance
between each plate. The distance from the first tray to the top of the column is
about 8 feet high. [c] [d] [e]
18
2.1 Autothermal Reformer (Isabelle Tay Sui Kim)
19
20
2.2 Fire Heater (Saw Meng Kiat)
21
22
23
2.3 Let-down Vessel (Vera Tanzil)
24
2.4 Distillation Column (Rachel Hu Jia Yun)
25
3.1 Bow-tie Diagram
26
3.2 Bowtie Diagram Description
Introduction:
As many hazards are involved in methanol synthesis, a bow tie diagram was
done to access potential hazards and damages and to come up with ways of
controlling the danger and mitigating losses. The “explosion/fire in the fired
heater” incident was chosen as the fired heater plays a huge role in methanol
production by producing the desired temperature of the process fluids. As the
heater operates under high temperature (805°C), there are a lot of potential
hazards that can be related to this particular equipment.
HAZARDS
As the radiant tubes are located close to the burner, should rupture in the
radiant tube occur, the flammable process fluid would then be in direct contact
with the flame, thus causing an explosion.
Preventative Measures:
With the mounting of sight doors on the casing, operators can have visual
access to the interior of the firebox. This allows operators to monitor any
abnormal behavior of burner flames.
Under positive firebox pressure, any hot gases that escape through the
sight door may injure unprotected observing operators. With the usage of
proper protective gear, operators can protect themselves from burns and
other injuries.
Even distribution of heat throughout the fired heater is crucial, as it will affect
the temperature of the outlet stream. Uncontrollable heating will cause the
pressure to build inside the heater, which may lead to explosion.
Preventative Measures:
Temperature sensors at both ends of the heater help to ensure the
temperature is within the desired range.
Should there be any abnormal deviation in the temperature, the alarm
system will be triggered and emergency response plan will be executed.
Proper pre-ignition purging of the fired heater is mandatory and crucial for its
safe operation. This is to prevent the accumulation of combustible gas in the
heater that may accidentally combust, and set off an explosion.
Preventative Measures:
Normally, the heater would be allowed to purge naturally for a period of
20-30 minutes on a cold light off, at the operator’s discretion.
27
There has to be four volume changes in the heater prior to light off, which
is impossible to measure via natural purge. This is why options such as
the Purge Blower and Fan are introduced.
Preventative Measures:
The safety shut off valve will prevent the inlet flow of the process fluids
into the heater once it reaches a certain level.
Certified shut off valves are of better quality and will not easily
malfunction.
The operation parameters for the burner are specific in order for the heater to
function safely and efficiently to produce the desired outlet stream. Any
malfunction, should be detected immediately to prevent accidents at the
equipment.
Preventative Measures:
The analyzer should be placed in the convection section for easier access.
It should not be placed near the burner, as the temperature is not
favorable.
Certified technicians should perform frequent inspection of the burner and
logbooks should always be properly updated.
As the inlet and valve transport explosive process fluids, should there be leakage
to the surroundings, and accidentally ignited, it will cause a fire or even an
explosion at the equipment.
Preventative Measures:
Pressure gauge or piezoelectric sensor should be installed in order to
detect even the slightest leakage in the inlet pipe and valve before
accidents occur.
Constant monitoring by qualified personnel will ensure preventive
measures (ie. replacing the pipe or valve) are taken.
Light off is done once every few years for fired heaters. Operators that are not
accustomed to the proper procedures may make mistakes that are costly and
dangerous.
Preventative Measures:
28
Concrete training regarding the function of every single component of the
heater as well as standard operating procedures after light-off will prepare
them for the event.
A supervisor who is present will be able to ensure that they conduct the
procedures properly and safely.
Preventative Measures:
Suspension or in repeated cases, termination will be acted upon any
employees who smoke in the plant as a way of deterring them from
contributing to unwanted accidents.
Any maintenance that causes sparks or naked flame, should be planned in
advance so that proper precautions can be taken beforehand.
CONSEQUENCES
Preparedness Control:
Special Emergency Response Team (SERT) should be notified and they
can carry out emergency response plan.
Employees will be evacuated to the assigned assembly point with at least
a distance of 10m to prevent further injuries.
Preparedness Control:
Isolation of the unit to prevent further spreading of combustible natural
gas to other parts of the plant.
If the fire or explosion is very serious, production at other places should
be stop if possible. As methane gas is easily ignited, if it spreads to other
equipment which might act as heat source, the damage to the plant could
be devastating.
Preparedness Control:
Emergency alarm system will trigger to indicate problem at the unit and to
warn workers
Preplanned emergency response plan will be carried out to mitigate
damage and impact to the equipment and workers’ safety.
Preparedness Control:
Workers who wear proper personal protective equipment can lessen the
risk of injuries.
29
Employees will be evacuated to the assigned assembly point to prevent
further injuries.
Preparedness Control:
Proper documentation of the whole event including details of how the fire
or explosion started and steps carried out in response will be useful in
terms of legal claims
Previously bought insurance policies can be claim to lessen financial
losses, if all the details of the accidents are in order (no insurance fraud).
Consequence 6: Pollution:
Preparedness Control:
Containment of the smoke particles from the incident will prevent
pollution as well as damage the health of employees.
Proper waste management will help minimize the impact of the ash and
smoke particles on the environment.
Preparedness Control:
Technicians will be on-call to provide immediate response to malfunction
of equipment components.
Alternative heaters will be use as a short-term response while waiting for
replacement or repairing of the heater
Preparedness Control:
Public relations consultant can provide the necessary information and
expertise in dealing with such crisis
An official press statement to the public to provide explanations and
official apology to those who are affected can help save the company’s
name.
Conclusion:
Great care must be taken with the installation, implementation and maintenance
of a fired heater. However, even though the hazards can be foreseen, and the
proper preventative measures can be put in place; there are still chances of
unwanted accidents. Thus, certain controls have to be preplanned to lessen the
consequences. Proper documentation should also be done not only for legal or
insurance purposes, but also other people are aware as to how to handle the
incident if it were to happen again in the future.
30
4.1 Extended Summary
The equipment that I have chosen is the Autothermal Reformer (ATR). The
particular features of the reformer are the burner, combustion chamber and the
catalyst bed. These three main features are important because they are part of
the pathway for the natural gas to be converted to syngas. They are specifically
chosen to complement each other. The burner will allow soot-free combustion,
which prevents carbon deposit on the catalyst, thus prolonging its life. The
conical combustion chamber protects the burner from the hot flame core and gas
while in recirculation. The locations of the three inlets are separate to allow a
more efficient and productive process flow. The natural gas and steam come in
from separate inlets and will meet and mix partially on the way to the burner,
where there will be equal mixing by the burner nozzle. The oxygen inlet is
introduced at the burner itself to ensure a constant oxygen flow there, in order
to maintain constant combustion. After passing through the catalyst bed, the
syngas flow through several small openings to the collection chamber, it will
then come out to the syngas outlet.
A few assumptions made were the dimensions and operating conditions of the
ATR. As there were contradicting operating conditions based on multiple
literature and sources, it was difficult to determine suitable conditions. The
dimensions were hard to determine, as the volume of the space from the
combustion chamber to the catalyst bed to the collection chamber depended on
how much natural gas would be entering the vessel. Since this volume is the
center of the reformer, other dimensions have to be able to support this basis.
Other minor assumptions were the composition of materials used and the price
of the equipment.
An improvement towards the design is to include the heat source for the
reformer such as copper coils or flue gas for inductive heating and combustion.
Another improvement is to include room in the reformer after the manhole, so
that there is space between the manhole and the refractory. This is to properly
depict the space for which technicians can perform maintenance or change the
catalyst beds.
In my opinion, the ATR is one of the most important equipment in the synthesis
of methanol via natural gas. Of course the earlier mentioned improvements
towards the design of the reformer will help to make it better commercially and
other adjustments can make this equipment better in terms of environmental
and safety.
31
4.2 Extended Summary
Based on the result of process economic analysis, few fire heaters are required
in order to meet the production capacity of methanol. This will eventually result
in greater cost of running and maintaining. In the market, each 20m height
carbon steel fire heater is sold at around USD 480,000. After considering the
high flow rate of our process fluid, which is 6674.846 kg/h and the need to
produce 50,000 tonnes of methanol per year, 3 fire heaters are being used. For
each fire heater, there is 30 days of down time in a year, which means the
machine will be operating only 335 days in a year. Besides, there will be 5
technicians being allocated to monitor the operation of fire heater and at least
one engineer/supervisor.
There are some areas of uncertainty in my heater design such as the way to
ensure uniform heating on the heater tubes. We do not take into consideration
about thermal expansion as well. Besides, in the heater design, there is no
special component which can accurately measure the amount of air being
aspirated into the burner.
The equipment design can be improved by making sure there is extra space in
the convection section tube layout for future installation of soot blowers.
Besides, the heater arrangements can be varied to allow for replacement of
individual tubes without disturbing the adjacent tubes. Some component can be
added in as well to ensure the film temperature wouldn’t reach that high which
can cause coke deposition.
32
4.3 Extended Summary
Leakage in the pipes, either inlet or outlet, is one of the issues regarding safety
and environmental. Safety wise, both inlet and outlet contain flammable gas(es)
which may severely cause explosion if is not taken care of. On the environmental
side, both inlet and outlet also contain greenhouse gases. Water pollution may
also occur due to the cleaning process of the vessel itself. Furthermore,
equipment including first aid kits and fire extinguisher should be available
nearby as an emergency response.
The major uncertainty in the chosen equipment is the interior design of the inlet
diffuser including the size and the angle of the vanes fitted in the inlet diffuser.
Another one includes the minimum and maximum distance between the inlet
diffuser and the liquid level.
There are several changes that could be done to this equipment design in order
to improve it. Firstly, a liquid level sensor or a peeping hole can be installed to
keep an eye on the rise and fall of the liquid level. Secondly, a valve can be
included after the liquid outlet to be in control of the flow of the liquid. Thirdly, a
temperature and pressure sensor can be installed to make sure that the fluid
coming in and out of the vessel are within the desired temperature range. Lastly,
a manhole can be added to the design as this will ease the cleaning and
maintaining processes of the equipment.
Overall, regarding the equipment I chose, which is the let-down vessel has a
significant role in the process of methanol synthesis as the separation of the
fluid to two different states in order to collect the desired product which in this
case is methanol in liquid state. Without it, separation of particular gases from
the liquid is going to be challenging.
33
4.1 Extended Summary
34
5.1 References
35
11.Sciencedirect.com, (2015). Autothermal reforming of methane to
synthesis gas: Modeling and simulation. [online] Available at:
http://www.sciencedirect.com/science/article/pii/S0360319908016121
[Accessed 29 Nov. 2015].
36
21.Fired process heaters. (n.d.). 1st ed. [ebook] Available at:
http://cdn.intechopen.com/pdfs-wm/11623.pdf [Accessed 12 Nov. 2015].
23.N. Jethva, M. (2013). Fired Heater Design and Simulation. 1st ed. [ebook]
Available at: http://www.ijettjournal.org/volume-4/issue-2/IJETT-
V4I2P215.pdf [Accessed 14 Nov. 2015].
24.Sigma Thermal, (2015). Direct Fired Heaters and Gas Fired Heaters -
Sigma Thermal. [online] Available at:
http://www.sigmathermal.com/direct-fired-heaters/ [Accessed 9 Dec.
2015].
37
31.Gas/Liquid Separation Technology. (n.d.). 1st ed. [eBook] Available at:
http://www.nt.ntnu.no/users/skoge/prost/proceedings/distillation10/DA20
10%20Sponsor%20Information/Sulzer/Gas_Liquid_Separation_Technolog
y_20090819.pdf [Accessed 8 Dec. 2015].
34.[c] Distillation Senior Design CHE 396. (2015). [online] Available at:
http://www.che.utah.edu/~ring/Design%20I/Articles/distillation%20desig
n.pdf [Accessed 1 Dec. 2015].
38
6.1 Material Safety Data Sheet (Methane)
39
40
41
42
43
6.2 Emergency Response Plan
In the event where the fire is minor in a contained area, the following steps
must be taken to avoid any accident to happen.
However, if the fire starts spreading or there is an explosion, the following steps
must be taken to minimize the causality.
Immediately sound the fire alarm with evacuation siren and proceed with
the fire safety evacuation plan.
Attend to victims and help them to come out from the plant.
Keep low if there is smoke coming out.
Contact the fire department, police and ambulance.
Shut down all plant processes from the control room. This can be done
through the team leader who can power down the mains at their
respective facilities.
All personnel are to be evacuated by following the emergency response
plan to the nearby assembly point.
At the assembly point, team leaders have to perform headcounts for their
respective departments. Report any missing personnel.
Do not use the elevators.
Do not return to the fire/explosion place unless there is missing
headcount.
After the incident, a detailed report with possible causes of fire/ explosion
is to be submitted by the plant safety department.
44
Second Action Plan: Spilling of chemicals
There are many chemicals (gases/ liquids) which can be found inside the
methanol plant. Some of it are:
45
6.3 Emergency Evacuation Plan
46
6.4 Plant Operation Accident Investigation Form[f]
Employee I.D.:____________________________________________________
Department: _____________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Conditions and Factors that Leads to the Accident: (e.g. poor maintenance,
weather, visibility, etc.)
________________________________________________________________
________________________________________________________________
________________________________________________________________
Was there any special permits/authorization needed for the activity? If yes,
please describe.
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Is Personal Protective Equipment used during the activity? If yes, please list the
PPE down.
47
________________________________________________________________
________________________________________________________________
Is there any equipment/utilities damaged due to the accident? If yes, please list
them down.
________________________________________________________________
________________________________________________________________
Please state Nature of Illness/Injuries due to the accident: (e.g. sprain, bruise,
burn, exposure to contaminant, etc.)
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Please state the type of the accident and describe it: (e.g. fall, exposure to
chemical, struck by an object, etc.)
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Investigator Name:
Investigator Signature:
Date:
48