07 Sn2013eu13sn 0001 Adm ss7 Netw Ewsd

Download as pdf or txt
Download as pdf or txt
You are on page 1of 94

Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Appendix: Administration of the SS7


Network in EWSD Classic

Contents
1 Message Transfer Part 3
1.1 Introduction 4
1.2 Own Signaling Point 6
1.3 Signaling Link Set 18
1.4 Signaling Link 34
1.5 Nailed-Up Connection 42
1.6 Signaling Routes 46
1.7 Sequence in the CCS7 Creation of the Signaling Network 66
1.8 Summary 68
2 Administration of Trunk related User Parts in the CP 73
2.1 Overview SS7 User 74
2.2 MML Commands for Administration of the Trunk Related UPs in the
CP 76
3 Exercise 79
4 Solutions 87

SN2013EU13SN_0001
1
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

2 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

1 Message Transfer Part

SN2013EU13SN_0001
3
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.1 Introduction
A signaling network consisting of
l signaling points
l signaling links
l signaling link sets
l signaling routes and signaling route sets
must be created by operator via MML commands.
With the aid of the appropriate database the MTP is then able to carry out its tasks.

4 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Originating Point, identified by


Signaling links
own Signaling Point Code
Signaling link set
SIEMENS D 900 SIEMENS D 900

0
... 16
...
31
0
... 16
Signaling link ... Signaling Point
31
set SIEMENS D 900 SIEMENS D 900
0
...

Ci ela
r c t ed
r
16

ui
t r sig
.. .

el n
at a l
ed i n
31

or g i n
no for
t c ma
irc tio
Signaling
ui n
t
link SIEMENS D 900 SIEMENS D 900

SIEMENS D 900 SIEMENS D 900

Signaling Point

Destination Point
identified by
Destination Point Code

Fig. 1 Signaling network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2013EU13SN_0001
5
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2 Own Signaling Point


1.2.1 Function and MML Command
Every signaling point can be uniquely identified within a network on the basis of its
code. This code can be made up of 14 or 24 bit and is entered in a structured form.
Besides, the function of a signaling point must be released, i.e. whether it is a
signaling transfer point or a signaling end point.
With the aid of this data the function message discrimination can be carried out, i.e.
the comparison of the received destination point code with the own signaling point
code.
The MML command for creating the own signaling point is shown in Fig. 2 Create
C7OP. The individual parameters are explained on the following pages.

6 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Own C7 Signaling Point

CR C7OP : SPC =.........,


NETIND =.........,
STPI =.........,
[SDL =.........,]
[SPCSIZE =.........,]
[SENDTFP =.........];

Fig. 2 Create C7OP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
7
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2.2 SPC (Signaling Point Code)


The signaling point code must be entered in structured form. This structure may
consist of one, two, three or four units. The required structure selection is country-
specific and can be defined only by patch.
At present the following structures can be offered:
In a network with network indicator NAT0 or NAT1 and 14 bits:
1. 4 units a-b-c-d
with a = 0 - 15 c = 0 - 15
b=0-7 d=0-7

2. 2 units a-b
with a = 0 - 31 b = 0 - 511

3. 3 units a-b-c
with a = 0 - 7, b = 0 - 15, c = 0 - 127

4. 1 units a
with a = 0 - 16383

A network with network indicator INAT0 allows a structure composed of 3 units.


3 units a-b-c
with a=0-7
b = 0 - 255
c=0-7
Inside the system and during signaling the structured code is always transferred as
an unstructured value.

8 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Signaling Point Codes (14 bit) a-b-c-d

national use:

• 14bit
• 5bit-9bit
• 3bit-4bit-7bit
• 4bit-3bit-4bit-3bit

international use ITU-T Q 708:

• 3bit-8bit-3bit
meaning:
Zone - Area- sign. point
e.g. 3-20-n

North America - one area of USA - sign. point

Fig. 3 Signaling point codes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
9
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2.3 Network Indicator


The network indicator indicates the scope of the signaling point code. As the
signaling point code with 14 bit D'16383 is insufficient to address all signaling points
world-wide, it is always used together with the network indicator.
The network indicator has the following meaning:
NAT0 National network provider's network
NAT1 Superordinate network between national network operators
INAT0 International network between network operators that have an
international signaling point code
INAT1 Not used.
As the network indicator recognizes only the NAT0, NAT1, INAT0 and INAT1 values,
the international addressing of signaling points remains incomplete, of course.
That is why the following method is used for international signaling:
The SPC is valid within one network only. Therefore the SPC and the NETIND must
be set anew for each transition e.g. NAT0->NAT1->INAT0->NAT1->NAT0. A pre-
requisite for this is that the gateway switching center belongs to both networks e.g.
NAT0 and NAT1, and that there is a clear international address for the end
destination.
The clear international address is not a problem for the ISDN user part (ISUP), as in
this case the called party address (called end) is addressed link by link anyway and
evaluated in each switching center.
However, for other users, e.g. mobile application part, a clear international address
must be made available which can be used for new address calculation. This new
calculation is carried out by SCCP. The international HLR, VLR, MSC ISDN etc. can
be also be sent as clear international address. These addresses are called Global
Titles.

10 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

NETIND (Network Indicator)

NAT0 national network of a national network operator

NAT1 national overlay network between national network operators

INAT0 international network between operators with an international SPC

INAT1 not used


Fig. 4 The four different network indicators

NAT0
SP SP
NAT0: 100
NAT1: 100 200
NAT1

NAT0 SP SP
NAT0: 200
100 NAT1: 200

SP Country X
NAT0: 300
INAT0: 100

INAT0

SP Country Y
NAT0: 100
NAT0 INAT0: 200

SP SP
200 300

Fig. 5 Network indicators in the net

SN2013EU13SN_0001
11
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2.4 STPI (Signaling Transfer Point Identifier):

= SP (Signaling point functions purely as a signaling end point)

= STP (Signaling point functions as signaling transfer point and signaling end
point)

A signaling point marked as signaling end point can distribute a received message to
its own users only. Should the address field indicate that a transfer is required, the
signaling point discards the message and increments the discarded-message
counter.

12 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

OP
MSU(OPC=18,DPC=19)
18

SP
STP 25
?
25 STPI=SP
(signaling end point)
Message will be discarded
STPI=STP
(signaling end point/ DP
signaling transfer point)
Message will be forwarded
19
Fig. 6 Signaling end point and/or signaling transfer point

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
13
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2.5 Further Parameters

SDL (Supported Data Length):


= 62 byte (used in some old fashioned networks)

= 272 byte

SPCSIZE (Signaling point code network size):


= NORMAL (14 bit addressing, possible for all user parts in all networks)

= EXTENDED (24 bit addressing, possible for all user parts in the national networks)

SENDTFP (Transfer prohibited functionality):


= OFF partner exchanges of an exchange with STP functionality are only
informed if the CCS7 Network Management detects the unavailability of
partners because of network failures
= ON partner exchanges of an exchange with STP functionality are informed if
the CCS7 Network Management detects either the unavailability of
partners because of network failures or the MTP cannot transfer
messages because no route to the requested DPC is created (database
failure)

14 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

SP
100
MSU
(OPC=100, Transfer prohibited
DPC=300) TFP is sent back

STP
200

SP
300
Fig. 7 Transfer prohibited

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
15
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.2.6 Further MML Commands


In addition to the already mentioned CR C7OP, there are further MML commands for
modifying, canceling and displaying own signaling point codes.

16 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Further commands to administer the


signaling point code:

• Modify
MOD C7OP : SPC = .......,
NETIND = .......,
STPI = .......,
SDL = .......,
SENDTFP = .......;
• Delete
CAN C7OP : SPC = .......,
NETIND = .......;

• Display
DISP C7OP ;

Fig. 8 Further C7OP MML commands

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:43:01


2118 OMT-00/EWSD0 2871/01075

DISPC7OP; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- OWN SIGNALING POINT

SPC NETIND STPI SDL SPCSIZE SENDTFP


-------------+------+----+---+--------+-------
0- 0- 4 NAT0 STP 272 NORMAL ON

Fig. 9 Example of DISP C7OP

SN2013EU13SN_0001
17
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3 Signaling Link Set


1.3.1 Function
A link set consisting of up to 16 links connects the own signaling point to a neigh-
boring signaling point which can either be a signaling end point or a signaling transfer
point. Only one link set can be created between two adjacent signaling points which
are specified via their SPC and NETIND (network indicator).
Every link set and the links it is made up of is clearly allocated to a network indicator
and is used as signaling route to reach a specific destination point code.

18 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

SP
Signaling link set:
100 Group of signaling links
to an adjacent signaling point
Signaling link set

SP
STP 300
200

SP
400
Fig. 10 Link sets

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
19
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3.2 MML Command

LSNAM (link set name):


= symbolic name of the link sets

SPC (signaling point code):


= SPC of the neighboring SP

NETIND (network indicator):


= NAT0 / NAT1 / INAT0 / INAT1

LSNO (link set number):


= 0...255 (number of the allocated element in the database)

LSK (load sharing key):


= 0...15 (described later)

ALTYPE (alarm type for LSET in NAC):


= CCSLSNAC (standard case major alarm)
CCSLSNEX (exception critical alarm)
CCSLSNAL (no alarming)

Alarm type for LSETs in UNA can be adjusted with


ENTR ALPRIO: ALUNIT=CCSLS,LINKSET=, ALPRIO= {CRITICAL|MAJOR|MINOR}

PERLTEST (periodic link test):


= OFF (no test)
ON (periodic test)

20 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Creation of Signaling Link set

CR C7LSET : LSNAM=.......,

SPC =.......,
NETIND = .......,
[LSNO =.......,]
[LSK = .......,]
[ALTYPE =.......,]
[PERLTEST = .......];

Fig. 11 Creation of a signaling link

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
21
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3.2.1 Loadsharing between Signaling Links (LSK)


The LSK (Loadsharing Key 0...15) parameter contains the key for the load
distribution of all traffic on a link set among the links allocated to it.
The link table of each link set contains 16 elements each filled with an active link of
this link set. When routing a message signal unit the link table element is selected
with the help of the SLS field (4 Bit: 0000...1111/D'0...15).
Which active link is used for routing a message signal unit depends on the way the
links are distributed over the link table. The LSK of the link set influences the
allocation of the available active links to the 16 elements of the link table. Finally this
means that the LSK determines the assignment of a given SLS to the active link to be
chosen.

1.3.2.1.1 Effect of the LSK on Structure of the Link Table


The link table is divided into so called traffic units. A traffic unit can occupy 1, 2 up to
16 elements of the link table. All elements occupied by the same traffic unit are filled
with the same active link.
l The LSK determines how many traffic units are managed in the link table. In other
words, the LSK specifies the maximum number of active links, which can be used
for message routing. To do this, the decimal LSK is converted into a binary value.
The number of bits which is set to 1 is decisive for the number of traffic units:
Number of traffic units = 2number of binary 1s in the LSK
e.g. LSK = 3: binary 0011 number of traffic units = 22 = 4
or
e.g. LSK = 7: binary 0111 number of traffic units = 23 = 8

22 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Number of traffic units = 2 Number of binary 1s in the LSK


LSK

Decimal Binary Number of bit Number of Number of link


positions to be differentiable table elements
analyzed traffic units (SLS Values) per
traffic unit

0 0000 0 1 16

1 0001 1 2 8
2 0010
4 0100
8 1000

3 0011 2 4 4
5 0101
6 0110
9 1001
10 1010
12 1100

7 0111 3 8 2
11 1011
13 1101
14 1110

15 1111 4 16 1

Fig. 12 Number of traffic units

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
23
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

l The LSK determines the allocation of the link table elements (addressed by SLS
values) to the traffic units. For this purpose the binary LSK value is placed over the
SLS field as a mask. The decimal value of the masked bits indicates the number of
the allocated traffic units:
e.g.: LSK = 3: binary = 0011 =>
SLS = XX00 => Traffic Unit 0
SLS = XX01 => Traffic Unit 1
SLS = XX10 => Traffic Unit 2
SLS = XX11 => Traffic Unit 3

24 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Example LSK=3 => B'0011 (4 Traffic Units)


for the SLS values B'XX00 => Traffic Unit 0
for the SLS values B'XX01 => Traffic Unit 1
for the SLS values B'XX10 => Traffic Unit 2
for the SLS values B'XX11 => Traffic Unit 3
SLS B‘0000 0 Link A
B‘0001 1 Link B
B‘0010 2 Link C
B‘0011 3 Link D Traffic Unit 0
B‘0100 4 Link A
B‘0101 5 Link B
B‘0110 6 Link C Traffic Unit 1
B‘0111 7 Link D
B‘1000 8 Link A
Traffic Unit 2
B‘1001 9 Link B
B‘1010 10 Link C
B‘1011 11 Link D Traffic Unit 3
B‘1100 12 Link A
B‘1101 13 Link B
B‘1110 14 Link C
B‘1111 15 Link D

Fig. 13 Example allocation of SLS to the traffic unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
25
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3.2.1.2 Distribution of the Active Links Among the Traffic Units


The link table contains only the active signaling links. The active links should be
represented as evenly as possible in the link table. There can only be a maximum
of as many links as there are traffic units.
The link table is set-up a new each time a link configuration takes place.
The method for setting up of the link table is as follows, it starts with traffic unit 0 and
will be run through until all traffic units in ascending sequence are filled:
Inspection of whether none, one or several of the active links are underrepresented in
the already filled traffic units.
l If one: the next traffic unit is filled with this link.
l If several: the next traffic unit is filled with the highest priority (set-up sequence
with CRC7 LINK) of these underrepresented links.
l If none: the next traffic unit is filled with the highest priority (set-up sequence with
CR C7LINK) of the links to be distributed.

26 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Example LSK=3 => B'0011 i.e. 4 Traffic Units


and four links activated step by step

Link table after activation of:


Link A Link A,B Link A,B,C Link A,B,C,D
0 Link A 0 Link A 0 Link A 0 Link A
1 Link A 1 Link B 1 Link B 1 Link B
2 Link A 2 Link A 2 Link C 2 Link C
3 Link A 3 Link B 3 Link A 3 Link D
4 Link A 4 Link A 4 Link A 4 Link A
5 Link A 5 Link B 5 Link B 5 Link B
6 Link A 6 Link A 6 Link C 6 Link C
7 Link A 7 Link B 7 Link A 7 Link D
8 Link A 8 Link A 8 Link A 8 Link A
9 Link A 9 Link B 9 Link B 9 Link B
10 Link A 10 Link A 10 Link C 10 Link C
11 Link A 11 Link B 11 Link A 11 Link D
12 Link A 12 Link A 12 Link A 12 Link A
13 Link A 13 Link B 13 Link B 13 Link B
14 Link A 14 Link A 14 Link C 14 Link C
15 Link A 15 Link B 15 Link A 15 Link D

Fig. 14 Allocation of links to the traffic units

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
27
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3.2.2 Permanent Link Test (PERLTEST)


If the PERLTEST parameter is set to ON, a link test of the links allocated to the link
set is carried out every 90 seconds.
The test checks the L2 functions between two adjacent SPs.
Testing and maintenance sends a Signaling Link Test Message (SLTM) to the
partner which includes a test pattern. The partner responds with a Signaling Link
Test Acknowledgement (SLTA) containing the reflected test pattern.
The following data are checked during the test:
1. the Signaling Link Code (SLC)
2. the OPC (SLTM-DPC = SLTA-OPC)
3. the test pattern (which is merely looped back in the acknowledgement)
The test is positive only if the link status is "in service".

28 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

SP 1. SLTM
SLTA
SP
2. SLTM
SLTA

1) Testing of A-side
2) Testing of B-side

SLTM Signaling Link Test Message


SLTA Signaling Link Test Acknowledgement
Fig. 15 Signaling link test

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
29
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.3.3 Further MML Commands


A C7 LSET can be modified with MOD C7LSET, canceled with CAN C7LSET and
displayed with DISP C7LSET.

30 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Further MML commands to administer the


Signaling Link Set:

• Modify
MOD C7LSET : LSNAM = .......,
{ALTYPE = .......,
LSK = .......,
PERLTEST = .......;}
• Cancel
CAN C7LSET : LSNAM = .......;
• Display
DISP C7LSET : LSNAM = .......,
LSNO = .......,
NETIND = .......,
FORMAT = STD or LONG;

STD: only link and linkset data

LONG: data about load distribution


inside the linkset

Fig. 16 Further MML commands

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
31
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

An example of DISP C7LSET is given on the opposite page. The LSET data,
inclusive of the semi-permanent and transient status links, is printed out.
An illustration of the link table can be seen in the last part of the printout. The link
table is divided into 16 traffic units in accordance with the LSK = 15. Both traffic units
contain the active link with LCOD 0 and LCOD 1 alternately.

32 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:42:42


2114 OMT-00/EWSD0 2871/03923

DISPC7LSET:LSNAM=TAC1TO544; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- SIGNALING LINK SET

LSNAM DPC NETIND LSNO LSK OST INH EST ALTYPE PERLTEST
------------+-------------+------+----+---+---+---+---+--------+--------
TAC1TO544 0- 0- 3 NAT0 0 15 ACT NO ACT CCSLSNAC OFF

INTERRUPTION TEXT JOB 2114

CONTINUATION TEXT 0001

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:42:43


2114 OMT-00/EWSD0 2871/03922

CCS7 -- DISPLAY SIGN. ELEMENTS -- SIGNALING LINK

LSNAM: TAC1TO544
DPC : 0- 0- 3 NETIND: NAT0

LCOD LINKNO SILTNO LTYPE OST IST EST REAS


----+------+------+-------+---+---+----+------
0 0 2 D64BWM ACT NOT ACT
1 1 3 D64BWM ACT NOT ACT

INTERRUPTION TEXT JOB 2114

CONTINUATION TEXT 0002

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:42:44


2114 OMT-00/EWSD0 2871/01074

CCS7 -- DISPLAY SIGN. ELEMENTS -- ACTUAL LINKS IN SIGN. LINK SET

LSNAM L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16


--------------------------------------------------------------------
TAC1TO544 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

END JOB 2114

Fig. 17 Example DISP C7LINKSET

SN2013EU13SN_0001
33
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.4 Signaling Link


1.4.1 Function
A signaling link is part of a link set and can be uniquely identified by a link code
(0...15).
The signaling link is assigned certain characteristics such as transmission rate and
correction procedure.
In addition, the link set is allocated a SILTD which represents the interface to the
64 kbit/s transmission channel.

34 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

0 SILTD
Signaling
SignalingLink
Link

Signaling
Link Set n SILTD
Signaling
SignalingLink
Link

15 SILTD
Signaling
SignalingLink
Link

Fig. 18 Signaling Link

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
35
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.4.2 MML Command

LSNAM (link set name):


= symbolic name of a link set

LCOD (link code):


= 0...15
the value fixes the signaling link code (SLC)
As only one link set may exist between two adjacent signaling points, the link
code between two adjacent signaling points is unique. It is important to ensure
that the same code is allocated to the signaling link in both nodes, as Level 3 will
check for matching codes when the link is activated (see CR C7LSET:
PERLTEST=ON).

SILTNO (SILT number):


= 0...255
physical SILT-number assigned to the link.

LINKNO (link number):


= 0...255
number of the database element.

LTYPE (link type)


= D64BWM
D64PWM
A04BWM
fixes the attribute of the link.
One of two different failure correction methods – the basic error correction method
and PCR correction method – can be selected for a signaling link.
The transmission rate can be defined, too. The third and final definition option refers
to the selection of a table of timer threshold values. At present one of the following
link types can be selected:
LTYPE Transmission rate Correction method
D64BWM: DIGIT 64 K basic
D64PWM: DIGIT 64 K PCR
A04BWM: ANALOG 4.8 K basic

36 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Create C7 Link
CR C7LINK: LSNAM = .......,
LCOD = .......,
SILTNO = .......,
LINKNO = .......,
LTYPE = .......;

Attention: Modification of an already created


link is not possible

Fig. 19 MML command for C7 link creation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
37
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.4.3 Further MML Commands

Blocking of signaling links


A link can be cancelled with CAN C7LINK. A prerequisite for this is that the link was
configured with CONF C7LINK on BL1.
The BL1 and BL2 status' can be input in the CONF C7LINK command:
l BL1 means that level 2 and 3 of the link are blocked, i.e. only the physical link
connection (level 1) still exists.
l BL2 means that only the level 3 of the link is blocked, i.e. LSSUs (level 2) continue
to be exchanged.

Inhibiting of signaling links


The so-called inhibit status (transient status) can be set for a signaling link via
MOD C7LINK. Inhibit means that the link is no longer used for user part messages
(level 3 is blocked). If a destination point threatens isolation (last not blocked or
inhibited link fails) however, the link is automatically put back into operation. The
same applies for recoveries.

38 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Further commands to administer


the Signaling Links:

• Cancel
CAN C7LINK : LSNAM = .......,
LCOD = .......;
• Configure
CONF C7LINK : LSNAM = .......,
LCOD = .......,
OST = .......,
UNCOND = .......;

OST = ACT (active)


BL1 (blocked 1)
BL2 (blocked 2)

UNCOND = YES (last link should be blocked)


NO
• Modify
MOD C7LINK : LSNAM = .......,
LCOD = .......,
INH = .......;

INH = Y (inhibit the link)


N (uninhibit the link)

• Display
DISP C7LINK : LSNAM = .......,
LSNO = .......,
LINKNO = .......,
LCOD =.......,
SILTNO =.......;

Fig. 20 Further MML commands

SN2013EU13SN_0001
39
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

The logging of C7LINKs is shown in the adjacent example. Apart from the operational
status (semi-permanent) a link still shows the effective status (transient) and the
inhibit status (transient).
Operational Status: BL1, BL2, PLA, ACT (administrative state)
Effective Status: ACT, MBL, UNA (effective system status)
Inhibit Status: LOC, REM, BTH, NOT (Inhibit status local, remote or on both sides)

40 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:40:55


2090 OMT-00/EWSD0 2871/03919

DISPC7LINK:LSNO=X; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- SIGNALING LINK

LSNAM LCOD LINKNO SILTNO LTYPE OST IST EST REAS


------------+----+------+------+-------+---+---+---+------
TAC1TO544 0 0 2 D64BWM ACT NOT ACT
TAC1TO544 1 1 3 D64BWM ACT NOT ACT
TAC1TO722 0 2 4 D64BWM ACT NOT ACT
TAC1TO722 1 3 5 D64BWM ACT NOT ACT

END JOB 2090

Fig. 21 Example DISP C7LINK

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
41
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.5 Nailed-Up Connection


As mentioned above, the signaling link is defined by the allocation of the signaling
link code and by the SILTD hardware. A SILTD module is responsible for one
signaling link in each case.
The physical connection to an adjacent signaling point is implemented via a random
time slot (1...31). This PCM time slot functions as a TRUNK which again is allocated
to a trunk group. The TRUNK is switched through semipermanently to the corres-
ponding SILTD module (nailed-up connection). A nailed-up connection is defined by
two equipment numbers. One equipment number is the PCM time slot of the TRUNK
while the other is the stage of the SILTD module. Every nailed-up connection can be
administered and switched through semipermanently in the switching network.

42 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

signaling link
equipment
trunk of a number
SN
special trunk
group incoming

nailed-up
connection
SILTD
module equipment
number

outgoing

Fig. 22 Nailed-up connection

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
43
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

Since a nailed-up connection always considers two positions (equipment numbers),


one incoming and one outgoing, the following rule is applied when creating a nailed-
up connection for signaling links:
l the position (equipment number) of the PCM time slot is always the incoming side
of the nailed-up connection
l the position (equipment number) of the SILTD time slot is always the outgoing side
of the nailed-up connection

A nailed-up connection is created via the command CR NUC.


l In the case of signaling links, the parameter TYPE must always be set to MUX
because the NUC leads to the multiplexer of the CCNC.
l The rule indicated above concerning the “incoming / outgoing ports” also applies
when the parameters LTGIC / LCIC (incoming port, i.e. PCM timeslot) and LTGOG
/ LCOG (outgoing port, i.e. SILTD) are used. The information units of the two
parameters contain the following:
a) trunk port: here the same values are used as for the parameter LTG/LC in the
command CR TRUNK, which was used to reserve this timeslot for
transportation of a signaling link (level1 of C7LINK)
b) SILTD port:
LTGOG: value obtained as output to the command DISP MUX
LCOG value is obtained with the aid of the allocation list in the TML
(command CR NUC). In this list one can find the corresponding
information units for every SILTD module:

TIP
The MML command STAT C7L1 displays per signaling link, which SN (0 or 1) is used
for the active part of the duplicated NUC.

44 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Commands to administer the nailed-up connection

• Create
CR NUC: NUC = .......,
LTGIC = ......., LCIC=....,
LTGOG = ....., LCOG=...,
TYPE = MUX;

LTGIC = <ltgset-ltg> of LTG where PDC with signlaing link is connected to


LCIC= <diu–port> of pcm-timeslot used as signaling link
LTGOG = <ltgset–SDCno> of MUX
LCOG= SILT number converted into pseudo <diu-port>

• Cancel
CAN NUC: NUC = .......;
• Display
DISP NUC: NUC = .......;
• Activate
ACT NUC: NUC = ........;

Fig. 23 MML command for NUC administration

Prerequisite for a NUC

CR TGRP: TGNO= ,
OPMODE= IC,
GCOS= CCSLGRP;

CR TRUNK: TGNO= ;
LTG= <ltgset-ltg> of C7LINK
LC= <diu-timeslot> of C7LINK
LCOS= DIGSIG....;
Fig. 24 Prerequisite for a CR NUC

SN2013EU13SN_0001
45
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.6 Signaling Routes


1.6.1 Functions of the Destination Point
In every signaling point of a network, all other signaling points of the same network to
which messages can be sent and received respectively must be created as
destination points. These destination points can be reached from the own signaling
point either via a direct signaling link set (i.e. destination point is adjacent) or via one
or more intermediate signaling points, so-called signaling transfer points. The link
sets to another signaling point of the own network are known as routes. Thus, a
destination point is characterized by a destination point code (signaling point code of
the destination point), by the corresponding network indicator and by the routes (link
sets) which lead to it directly or indirectly.

46 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Destination
DestinationPoint
Point

message

Destination
DestinationPoint
Point
Specification
Specification

Link set

Route
RouteSelection
Selection 1..8

Fig. 25 Signaling routes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
47
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.6.2 Own Area and Foreign Area


Whenever state transitions occur in the signaling network, the signaling network
management must inform the other network elements. In a large signaling network
this leads to a vast number of messages. To prevent such message floods the
destination points can be divided into two groups: the points belonging to the own
area and the points belonging to the foreign area. In the own area all signaling
network management functions are performed, while in the foreign area the signaling
network management functions performed are restricted.
The foreign area is divisible into several routing areas. The division of the network
into own and foreign areas is defined separately in every signaling point. This means
a destination point may belong to the own area of signaling point A but to the foreign
area of signaling point B.

48 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Routing Area 1

Routing Area 2

STP STP

Routing Area 3
STP
STP
STP
SEP
STP
SEP
own STP Routing Area n
own area

foreign area

Fig. 26 Own and foreign areas

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
49
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

l Signaling points must be in the own area if:


there is a circuit group leading there
there is a signaling link leading there
If e.g. a signaling link between two signaling points of the own area fails, all other
signaling points in the own area are informed of this, i.e. network management is
guaranteed only in the own area.
Example:
Signaling link X ® Y has failed. X sends a Transfer Prohibited to D specifying that
DPC Y is no longer available. D can not switch over to the next link set to Y and
forwards the message to A and B. A does not forward the message because Y does
not belong to the own area of A.

l Signaling points should be located in a foreign area if:


the number of signaling points to be reached exceeds 2048
the message flood is to be stemmed for link failures

50 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

foreign area
for A SP

SP Y
x

TFP

TFP
SP
D
SP adjacent
SP
Circuit
A connection
B
own area adjacent
of SP A
TFP SP
C
Legend: TFP not forwarded by SP A because
Signaling link
SP Y in a foreign area
Circuit trunk

Fig. 27 Example for signaling management

SN2013EU13SN_0001
51
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.6.2.1 Creation of the Destination Point in the Own Area


As explained beforehand, the destination point is characterized by its DPC, NI and
the list of the signaling routes leading to it.

PRD (possible route directions):


= <lsnam1> & <lsnam2> & ...
Up to 8 link sets identified by their symbolic names can be assigned to a
destination point as possible route.
The sequence of these routes determines the priority of the signaling route.
In the most simple case, i.e. if there is no load sharing, the first route is the active
one and all the others are only used if the route preceding in each case fails.

LSK (load sharing key):


= 0 no load sharing
1-4 load sharing

52 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Create a destination point

CR C7DP: DPC = .........,


NETIND = .........,
PRD = .........,
LSK = .........;

Fig. 28 MML command CR destination point in the own area

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
53
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.6.2.2 Loadsharing between Routes


As the load is shared between only the first 2 active routes, the analysis of one bit in
the SLS field is sufficient to implement load sharing. The operator defines the bit
which is relevant for load sharing by MML.
As load sharing can take place only between two signaling link sets, the 16 possible
SLS values are divided into two halves (message stream groups). The term message
stream group is used to describe all the messages using the same link set to reach
one particular destination.
In other words: to transport the traffic to a specific destination (destination-oriented
load sharing)
l only one message stream group is used (if there is no load sharing) or
l two message stream groups are used (if load sharing is implemented).
The operator (LSK) specifies which bit in the SLS field will be analyzed. The selected
bit defines the assignment of message streams to message stream groups.

54 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

LSK SLS field Message stream


group number

0 XXXX 0 or 1st active route

Fig. 29 No loading sharing

LSK SLS field Message stream


group number

1 XXX0 0 or 1st active route

XXX1 1 or 2nd active route

2 XX0X 0 or 1st active route

XX1X 1 or 2nd active route

3 X0XX 0 or 1st active route

X1XX 1 or 2nd active route

4 0XXX 0 or 1st active route

1XXX 1 or 2nd active route

Fig. 30 Load sharing

SN2013EU13SN_0001
55
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

The assignment of SLS field to message streams, and therefore to message


stream groups is fixed (semi permanent) and is described as static routing
information.
The link sets that actually carry the traffic are termed "current routes". Such link sets
can only be signaling routes that are in service at the time of transport, and each time
no more than two. Should one of the current routes fail, it is replaced by another
active signaling route, namely the one with the highest priority. This routing
information is termed dynamic (as opposed to fixed) and identifies the assignment of
signaling routes to message stream groups.
The allocation of routes to the message stream groups is carried out due to the
sequence of the linksets in the PRD parameter. It does not only give the names but
also the priority of the link set to be used.
Example: The following route possibilities are available to reach destination point B:
CR C7DP: DPC= B, PRD= AB&AC&AD, LSK=1;
Under the assumption that the AB and AC routes have active links available and can
consequently transport signaling load, load sharing occurs between AB and AC with
the LSK = 1. Route AD would be used only in the event of AB or AC failing. The LSK
= 1 evaluates the first bit of the SLS field, if this bit is set to 0, routing would occur via
message stream group 0 and therefore via route AB; if it is set to 1, routing would
occur via message stream group 1 and thus via route AC. With reference to ISDN
user part (ISUP) traffic, for example, this would mean that even CICs are routed via
AB and odd CICs are routed via AC.

56 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

STP
C
ROUTE AC

SEP SEP
A B
ROUTE AB

ROUTE AD

STP
D CIC SLS Route
CR C7DP:DPC=B, n-0 0000 AB
PRD=AB&AC&AD, LSK=1,....;
n-1 0001 AC

n-2 0010 AB

n-3 0011 AC

.... .... ....


Legend:
Signaling link n-15 1111 AC

Fig. 31 Example of LSK for routes

SN2013EU13SN_0001
57
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

58 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Further Commands

Cancelation

CAN C7DP: DPC=....., NETIND=......;

Configuration

CONF C7DP: DPC=....., NETIND=......, OST= ......., UNCOND=....;


OST=ACT (active)
ABL (administrativly blocked)

UNCOND = NO (configured after operator confirmation)


YES (no confirmation necessary)

Modification

MOD C7DP DPC=....., NETIND=......, LSNAM1=...., LSNAM2=......,


LSPRI1=....., LSK=........;

Display

DISP C7DP: DPC=....., NETIND=......, OST= ......., EST=........;

DISP C7RSET: DPC=....., NETIND=......;

Fig. 32 Further MML commands

TIP
With the MML command DISP C7LSETDP all DPCs are listed which can be reached
via a given link set.

SN2013EU13SN_0001
59
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

The adjacent display of a route set (of all routes forwarding to a destination point) dis-
plays the list of available or active routes in the upper area. The PRI field names the
route priority, i.e. the criteria according to which the routes are distributed among the
various message stream groups. The CUR. ROUTE field gives information about the
routes currently available, i.e. the routes via which signaling traffic actually flows.

60 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:41:52


2105 OMT-00/EWSD0 2871/03927

DISPC7RSET:DPC=0-0-3,NETIND=NAT0; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- SIGNALING ROUTE SET

DPC: 0- 0- 3 NETIND: NAT0 LSK: 0 OST: ACT EST: ACT

LSNAM PRI CUR.ROUTE INH EST


------------+---+---------+---+---
TAC1TO544 1 YES NO ACT
TAC1TO622 2 NO NO ACT

END JOB 2105

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:41:15


2097 OMT-00/EWSD0 2871/03917

DISPC7DP:DPC=X-X-X,NETIND=NAT0; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- DESTINATION POINT

DPC NETIND OST EST


-------------+------+---+---
0- 0- 1 NAT0 ACT ACT
0- 0- 3 NAT0 ACT ACT

END JOB 2097

Fig. 33 Example of destination point / route set display

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
61
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.6.2.3 Creation of the Destination Point in the Foreign Area


Destination points situated in one routing area can be reached via common routes.
This is why the administration is subdivided into three steps:
l Creation of a routing area and allocation of routes via which the routing area can
be reached.
l Creation of destination points and allocation to the routing area.
l Configuration of the routing area.

62 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Destination Point and Routing Area

CR C7RTAREA: RANAM =......., NETIND =........, PRD =.........;

CR C7DP: RANAM =........, DPC =..........;


RANAM = symbolic name of routing areas

CONF C7RTAREA: RANAM =........, OST = ..........., UNCOND =..........,


OST = ACT (active)
ABL (administratively blocked)
UNCOND = NO
YES

MOD C7RTAREA: RANAM =........, LSNAM1 =......., LSNAM2 =.......,


LSPRI1 =.........,LSK =..........;

CAN C7RTAREA: RANAM =........, LSNAM =..........;

CAN C7DP: RANAM =........., DPC =........;

DISP C7RTAREA: RANAM =........;

Fig. 34 MML commands for destination points in a routing area

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
63
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

The adjacent example shows the display of all routing areas which are set up.
Only an overview of the available routing areas and allocated DPCs is given here.
If you enter the name of a routing area though, you will also receive the route set
information for the routing area.

64 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:43:12


2119 OMT-00/EWSD0 2871/02344

DISPC7RTAREA:RANAM=X; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- ROUTING AREA

RANAM NETIND DPC IN ROUTING AREA


-------------+-------+------------------------------
FOREIGN NAT0 0- 0- 5

END JOB 2119

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:43:36


2129 OMT-00/EWSD0 2871/03928

DISPC7RTAREA:RANAM=FOREIGN; EXEC'D

CCS7 -- DISPLAY SIGN. ELEMENTS -- ROUTING INFORMATION

RANAM: FOREIGN NETIND: NAT0 LSK: 0 OST: ACT EST: ACT

LSNAM PRI CUR.ROUTE INH EST


------------+---+---------+---+---
TAC1TO544 1 YES NO ACT
TAC1TO722 2 NO NO ACT

INTERRUPTION TEXT JOB 2129

CONTINUATION TEXT 0001

TAC1/CTYCPZ1V1150/P18/000 98-05-11 11:43:36


2129 OMT-00/EWSD0 2871/02345

CCS7 -- DISPLAY SIGN. ELEMENTS -- ROUTING AREA

RANAM NETIND DPC IN ROUTING AREA


-------------+-------+------------------------------
FOREIGN NAT0 0- 0- 5

END JOB 2129

Fig. 35 Routing area displays

SN2013EU13SN_0001
65
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.7 Sequence in the CCS7 Creation of the Signaling


Network

66 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

• Create own signaling point


CR C7OP

• Create link set


CR C7LSET

• Create route set in own area


CR C7DP

• Create route set in foreign area


CR C7RTAREA
CR C7DP

• Create links
CR C7LINK
CONF C7LINK

• Create nailed up connection


CR TGRP: GCOS = CCSLGRP
CR TRUNK: LCOS = DIGSIGxx
CR NUC
ACT NUC

• Activate destination point code


CONF C7DP
CONF C7RTAREA

Fig. 36

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
67
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.8 Summary
1.8.1 Allocation of CCS7 Database Objects to MML Commands
l The signaling message is created (or evaluated) by the corresponding user part for
the circuit connection (user channel) or by the corresponding “application part“ for
non-circuit-related connections or evaluated for incoming messages.
l Due to the fixed assignment of the sign. point code of the partner exchange to
each user channel trunk group (ENTR C7TGREL), the destination point code for
user channel-oriented signaling (e.g. ISUP) is available. For non-user channel-
oriented connections, special signaling control functions deliver the appropriate
destination point code as a routing label for the message.
l The own signaling point code flows into the message as the sender. It is specified
with the command CR C7OP.
l Up to 8 signaling link sets can be allocated to a destination point as possible
signaling routes. The route allocation and the definition of the destination point
code are done with the command CR C7 DP.
l A link set specifies a group of signaling links to an adjacent signaling point. It is
created with the command CR C7LSET.
l A signaling link allocates a SILTD module to a signaling link set. The
corresponding SILTD must be linked via a nailed-up connection with a PCM time
slot which leads to the corresponding adjacent signaling point. A signaling link is
administered using the command CR C7LINK.
l With the command CR NUC, the equipment number of the SILTD is semiper-
manently linked with the equipment number of the trunk. This trunk can be used
exclusively for signaling and must be allocated to a trunk group.

68 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

non circuit related


speech trunk group
messages
CR C7OP

in the message own signaling


ENTR C7TGREL
point code

destination point

......
CR C7DP

link set link


CRset
DEST CR C7LSET

link link Link Link CR C7LINK

SILTD SILTD CR NUC

trunk group trunk group

trunk trunk

Fig. 37 MML commands, CCS7 base objects and physical connection

SN2013EU13SN_0001
69
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

1.8.2 Allocation of MML Commands to the 4 Levels


l Level1
For level 1 you need to specify a trunk group with GCOS = CCSLGRP and a trunk.
This determines the physical time slot of the signaling link.
The time slot and the SILT D module are connected via the switching network with
the aid of a nailed-up connection. The connection is carried out with the commands
CR NUC and ACT NUC.
l Level 2
The SILT D module is configured from Status planned to Status active via the CONF
CCNC command.
l Level 2-3
Levels 2 and 3 are connected via the set up of a signaling link. This connection is
defined with CR C7LINK and the SILT and LSNAM parameters.
l Level 3
Using CR C7LSET/ CR C7DP or C7RTAREA, the routing function in level 3 is
supplied with the relevant data, as a selection of routes including a selection
specification (LSK) is made available here to a destination point or routing area.
The discrimination function in level 3 is supported with CR C7OP. This means that,
with help from the own SPC, the signaling point can decide whether it functions as a
signaling transfer point or as signaling end point for this message.
l Level 3-4
The C7 trunk group relation represents the link between the traffic orientated user
parts e.g. ISDN user parts (ISUPs) and level 3. Here the connection of a trunk group
and a DPC is determined.

70 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

User
User Parts e.g. ISUP Part

ENTR C7TGREL

CR C7DP/C7RTAREA
CR C7OP
Signaling network functions level 3
CR C7LSET

CR/CONF C7LINK

CONF CCNC: MTP


UNIT=SILT-n.. Signaling link functions level 2

CR NUC
ACT NUC
CR TGRP Signaling data link functions level 1
CR TRUNK

Fig. 38 MML commands and the 4 level model

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
71
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

72 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

2 Administration of Trunk Related User Parts


in the CP

SN2013EU13SN_0001
73
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

2.1 Overview SS7 User


The permitted user parts per destination point must be made known in order to
enable distribution of the message signal units (MSU) among the corresponding user
parts, or to send user part MSUs to the corresponding destination points.
The users currently being used are:
l for user channel (trunk) related signaling: ISDN user part (ISUP), TUP and TUP+
l for non traffic channel orientated signaling: SCCP/TCAP for signaling with the IN-
SCP (INAP) or for handling of ISDN supplementary services ISS (e.g.
CCBS/CCNR)
In an EWSD Powernode only the trunk related user parts are created in the CP, the
SSCP is only administered in the SSNC (see chapter about SCCP administration).

74 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

TCAP User
e.g. INAP, ISS

TCAP
ISUP TUP

SCCP

MTP

Fig. 39 CCS7 protocol stack

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
75
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

2.2 MML Commands for Administration of the Trunk


Related UPs in the CP
Creation of C7 USER
With the help of the CR C7USER MML command, the relevant user name (e.g. ISDN
user part ISUP) is allocated to a destination point code and a network name. The
C7USER of all known DPCs of the own network must be set up here.
As well as setting up, it is also possible to display and cancel the C7USER.

Creation of C7 TGREL
After the trunk related UPs are created, the so called C7TGREL can be entered for
each TRGP.
The C7 trunk group relation (C7TGREL) represents the link between the traffic
orientated user parts e.g. ISDN user part (ISUP) and level 3. Here the linkage of a
trunk group and a DPC is determined, this linkage is required for the "allocation
function"

76 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Administration of C7USER
CR C7USER: DPC= , NETNAME=, USNAME=ISUP,.... ;

DISP C7USER: DPC= , NETNAME= ,USNAME=ISUP,.... ;

CAN C7USER: DPC= , NETNAME= ,USNAME=ISUP,.... ;

TAC1/000TAC1MPS/NCGCBK1V1530/P00/113 02-03-08 11:53:16

3344 NetM IPATH4N2 2871/09116

DISPC7USER:DPC=0-0-3,NETNAME=TRAINING; EXEC'D

CCS7 -- USER RELATED DATA

DPC OSPC NETNAME USNAME PCMTYP CICSIZE


--------------+--------------+-------------+-------+-------+--------
0-0-3 0-0-1 TRAINING ISUP DIU30 CIC12

END JOB 3344

Fig. 40 C7 user administration

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SN2013EU13SN_0001
77
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

78 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

3 Exercise

SN2013EU13SN_0001
79
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

80 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Exercise 1
Title: CCS 7 administration
Objectives: The participant will be able to check command files for
administration of CCS 7 signaling connections
Prerequisite: none
Task
You have received the following MML commands in a command file. Check the
commands to prevent errors. Determine whether the commands are false or correct.
Mark the faults as applicable.
Test
<CMDFILE;
<CRC7LSET:LSNAM=Z008F ,SPC=5-7-0-0,NETIND=NAT1, LSK=15; Correct
False
<CRC7LSET:LSNAM=Z902F ,SPC=2-15-4-0, NETIND=NAT0, LSK=15;
Correct
False
<CRC7DP:DPC=2-0-4-0,NETIND=NAT0,PRD=Z902F&Z008F ,LSK=4;
Correct
False
<CONFC7DP:DPC=2-0-4-0,NETIND=NAT0,OST=ACT;
Correct
False
<CRC7LINK:LSNAM=Z008F ,LCOD=0,SILTNO=17,LTYPE=D64BWM;
Correct
False
<CONFC7LINK:LSNAM=Z008F ,LCOD=0,OST=ACT;
Correct
False

SN2013EU13SN_0001
81
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

82 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

<CRC7LINK:LSNAM=Z008F ,LCOD=1,SILTNO=42,LTYPE=D64BWM;
Correct
False
<CONFC7LINK:LSNAM=Z008F ,LCOD=1,OST=ACT;
Correct
False
<CRC7LINK:LSNAM=Z902F ,LCOD=0,SILTNO=16,LTYPE=D64BWM,LINKNO=1;
Correct
False
<CONFC7LINK:LSNAM=Z902F ,LCOD=0,OST=ACT;
Correct
False
<CRTGRP:TGNO=Z008F ,OPMODE=BW,GCOS=CCSLGRP!
Correct
False
:TGNO=Z902F ,OPMODE=BW,GCOS=CCSLGRP;
Correct
False
CRTRUNK:TGNO=Z008F ,LNO=1,LTG=0-12,LC=0-16,LCOS=DIGSIG22!
Correct
False
:TGNO=Z008F ,LNO=2,LTG=0-13,LC=0-16,LCOS=DIGSIG22!
Correct
False
:TGNO=Z902F ,LNO=1,LTG=0-12,LC=0-17,LCOS=DIGSIG22!
Correct
False
<CRNUC:NUC=SIL042,LTGIC=0-13,LCIC0-16,LTGOG=0-1,LCOG=1-5,TYPE=MUX;
<ACTNUC:NUC=SIL042,UNCOND=N; Correct
False
<CRNUC:NUC=SIL017,LTGIC=0-12,LCIC=0-16,LTGOG=0-1,LCOG=0-18,TYPE=MUX;
<ACTNUC:NUC=SIL017,UNCOND=N; Correct
False
<CRNUC:NUC=SIL016,LTGIC=0-12,LCIC=0-17,LTGOG=0-1,LCOG=0-2,TYPE=MUX;
<ACTNUC:NUC=SIL016,UNCOND=N; Correct
False
<CRC7USER:USNAME=ISUP,DPC=2-0-4-0,NETIND=NAT1,PCMTYP=DIU30;
Correct
False
<ENDFILE;
Correct
False

SN2013EU13SN_0001
83
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

84 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Exercise 2
Title: Administration of a Signaling Network
Objectives: The participant is able to create the database for a ISUP
signaling network
Pre-requisite: none
Task

Enter all MML commands to enable the shown configuration!

Create the TGRP with GCOS=CCSLGRP and the signaling link set with LSK=15!

TAC4
TAC4
OPC=0-5-2
OPC=0-5-2
NETIND=INAT0
NETIND=INAT0 LCOD=2,
LCOD=1, STPI=STP
STPI=STP SILT4,
SILT1, LSK=0
LSK=0 0-3-3-16
0-4-2-16

LCOD=2, LCOD=1,
SILT3, SILT2,
0-4-3-16 0-3-2-16 LCOD=2,
LCOD=1,
SILT1, SILT4,
0-4-2-16 LCOD=2, LCOD=1, 0-4-3-16
SILT3, SILT2,
0-4-3-16 0-4-2-16
LCOD=1, LCOD=1,
LX622
LX622 SILT2, LX566
LX566
SILT1,
OPC=0-5-0
OPC=0-5-0 0-3-2-16 0-3-2-16 OPC=0-5-1
OPC=0-5-1
NETIND=INAT0
NETIND=INAT0 NETIND=INAT0
NETIND=INAT0
STPI=STP
STPI=STP LCOD=2, STPI=STP
STPI=STP
LCOD=2,
LSK=0
LSK=0 SILT3, LSK=0
LSK=0
SILT4,
0-3-3-16 0-3-3-16

Fig. 41

SN2013EU13SN_0001
85
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

86 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

4 Solutions

SN2013EU13SN_0001
87
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

88 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Solution 1
Title: CCS 7 administration
Objectives: The participant will be able to implement administration of
CCS 7 signaling connections
Prerequisite: none
Task
You have received the following MML commands in a command file. Check the
commands to prevent errors. Determine whether the commands are false or correct.
Mark the faults as applicable.
Test
<CMDFILE;
<CRC7LSET:LSNAM=Z008F ,SPC=5-7-0-0,NETIND=NAT1, LSK=15; Correct
False
<CRC7LSET:LSNAM=Z902F ,SPC=2-15-4-0, NETIND=NAT0, LSK=15;
Correct
False
<CRC7LSET:LSNAM=Z018F ,SPC=5-7-6-0,NETIND=NAT0,LSK=15;
Correct
False
<CRC7DP:DPC=2-0-4-0,NETIND=NAT0,PRD=Z902F&Z008F ,LSK=4;
Correct
False
<CONFC7DP:DPC=2-0-4-0,NETIND=NAT0,OST=ACT;
Correct
False
<CRC7LINK:LSNAM=Z008F ,LCOD=0,SILTNO=17,LTYPE=D64BWM;
Correct
False
<CONFC7LINK:LSNAM=Z008F ,LCOD=0,OST=ACT;
Correct
False

SN2013EU13SN_0001
89
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

<CRC7LINK:LSNAM=Z008F ,LCOD=1,SILTNO=42,LTYPE=D64BWM;
Correct
False
<CONFC7LINK:LSNAM=Z008F ,LCOD=1,OST=ACT;
Correct
False
<CRC7LINK:LSNAM=Z902F ,LCOD=0,SILTNO=16,LTYPE=D64BWM,LINKNO=1;
Correct
False
<CONFC7LINK:LSNAM=Z902F ,LCOD=0,OST=ACT;
Correct
False
<CRTGRP:TGNO=Z008F ,OPMODE=BW,GCOS=CCSLGRP!
Correct
False
:TGNO=Z902F ,OPMODE=BW,GCOS=CCSLGRP;
Correct
False
CRTRUNK:TGNO=Z008F ,LNO=1,LTG=0-12,LC=0-16,LCOS=DIGSIG22!
Correct
False
:TGNO=Z008F ,LNO=2,LTG=0-13,LC=0-16,LCOS=DIGSIG22!
Correct
False
:TGNO=Z902F ,LNO=1,LTG=0-12,LC=0-17,LCOS=DIGSIG22!
Correct
False
<CRNUC:NUC=SIL042,LTGIC=0-13,LCIC0-16,LTGOG=0-1,LCOG=1-5,TYPE=MUX;
<ACTNUC:NUC=SIL042,UNCOND=N; Correct
False
<CRNUC:NUC=SIL017,LTGIC=0-12,LCIC=0-16,LTGOG=0-1,LCOG=0-18,TYPE=MUX;
<ACTNUC:NUC=SIL017,UNCOND=N; Correct
False
<CRNUC:NUC=SIL016,LTGIC=0-12,LCIC=0-17,LTGOG=0-1,LCOG=0-2,TYPE=MUX;
<ACTNUC:NUC=SIL016,UNCOND=N; Correct
False
<CRC7USER:USNAME=ISUP,DPC=2-0-4-0,NETIND=NAT1,PCMTYP=DIU30;
Correct
False
<ENDFILE;
Correct
False

90 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Solution 2
Title: Administration of a Signaling Network
Objectives: The participant is able to create the database for a ISUP
signaling network
Pre-requisite: none
Task

Enter all MML commands to enable the shown configuration!

Create the TGRP with GCOS=CCSLGRP and the signaling link set with LSK=15!

TAC4
TAC4
OPC=0-5-2
OPC=0-5-2
NETIND=INAT0
NETIND=INAT0 LCOD=2,
LCOD=1, STPI=STP
STPI=STP SILT4,
SILT1, LSK=0 LTG=0-3
LTG=0-4 LSK=0
LC=3-16
LC=2-16

LCOD=2, LCOD=1,
SILT3, SILT2,
LTG=0-4 LTG=0-3
LCOD=1, LC=3-16 LC=2-16 LCOD=2,
SILT1, SILT4,
LTG=0-4 LTG=0-4
LCOD=2, LCOD=1,
LC=2-16 LC=3-16
SILT3, SILT2,
LTG=0-4 LTG=0-4
LC=3-16 LC=2-16
LCOD=1, LCOD=1,
LX622
LX622
SILT2, SILT1, LX566
LX566
LTG=0-3
OPC=0-5-0
OPC=0-5-0 LC=2-16
LTG=0-3 OPC=0-5-1
OPC=0-5-1
NETIND=INAT0 LC=2-16 NETIND=INAT0
NETIND=INAT0 NETIND=INAT0
STPI=STP
STPI=STP STPI=STP
STPI=STP
LCOD=2, LCOD=2,
LSK=0
LSK=0 SILT3, LSK=0
LSK=0
SILT4,
LTG=0-3 LTG=0-3
LC=3-16 LC=3-16

Fig. 42

SN2013EU13SN_0001
91
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

Data in LX622
<CMDFILE;
<SETCFOPT:ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;

<CRC7OP:SPC=0-5-0,NETIND=INAT0,STPI=STP;

<CRTGRP:TGNO=x566C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=x566LS,SPC=0-5-1,NETIND=INAT0,LSK=15;
<CRTGRP:TGNO=TAC4C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=TAC4LS,SPC=0-5-2,NETIND=INAT0,LSK=15;

<CRC7DP:DPC=0-5-1,NETIND=INAT0,PRD=x566LS&TAC4LS,LSK=0;
<CONFC7DP:DPC=0-5-1,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-1,NETIND=INAT0;
<CRTRUNK:TGNO=x566C,LTG=0-3,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=x566C,LTG=0-3,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=x566LS,LCOD=1,SILTNO=2,LTYPE=D64BWM;
<CRC7LINK:LSNAM=x566LS,LCOD=2,SILTNO=4,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=x566LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=x566LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=2,OST=MBL;
<CONFDIU:LTG=0-3,DIU=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=3,OST=MBL;
<CONFDIU:LTG=0-3,DIU=3,OST=ACT;
<CANTRDAT:TGNO=x566c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=x566c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S2NUC1,LTGIC=0-3,LCIC=2-16,LTGOG=0-1,LCOG=1-0,TYPE=MUX;
<ACTNUC:NUC=S2NUC1;
<CRNUC:NUC=S4NUC1,LTGIC=0-3,LCIC=3-16,LTGOG=0-1,LCOG=2-0,TYPE=MUX;
<ACTNUC:NUC=S4NUC1;

/
<CRC7DP:DPC=0-5-2,NETIND=INAT0,PRD=TAC4LS&x566LS,LSK=0;
<CONFC7DP:DPC=0-5-2,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-2,NETIND=INAT0;
<CRTRUNK:TGNO=TAC4C,LTG=0-4,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=TAC4C,LTG=0-4,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=TAC4LS,LCOD=1,SILTNO=1,LTYPE=D64BWM;
<CRC7LINK:LSNAM=TAC4LS,LCOD=2,SILTNO=3,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=TAC4LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=TAC4LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=2,OST=MBL;
<CONFDIU:LTG=0-4,DIU=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=3,OST=MBL;
<CONFDIU:LTG=0-4,DIU=3,OST=ACT;
<CANTRDAT:TGNO=TAC4c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=TAC4c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S1NUC1,LTGIC=0-4,LCIC=2-16,LTGOG=0-1,LCOG=0-16,TYPE=MUX;
<ACTNUC:NUC=S1NUC1;
<CRNUC:NUC=S3NUC1,LTGIC=0-4,LCIC=3-16,LTGOG=0-1,LCOG=1-16,TYPE=MUX;
<ACTNUC:NUC=S3NUC1;
<RESETCFOPT;
<ENDFILE;

92 SN2013EU13SN_0001
© 2002 Siemens AG
Appendix: Administration of the SS7 Network in EWSD Classic Siemens

Data in LX566
<CMDFILE;
<SETCFOPT:ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;

<CRC7OP:SPC=0-5-1,NETIND=INAT0,STPI=STP;

<CRTGRP:TGNO=x622C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=x622LS,SPC=0-5-0,NETIND=INAT0,LSK=15;
<CRTGRP:TGNO=TAC4C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=TAC4LS,SPC=0-5-2,NETIND=INAT0,LSK=15;

<CRC7DP:DPC=0-5-0,NETIND=INAT0,PRD=x622LS&TAC4LS,LSK=0;
<CONFC7DP:DPC=0-5-0,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-0,NETIND=INAT0;
<CRTRUNK:TGNO=x622C,LTG=0-3,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=x622C,LTG=0-3,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=x622LS,LCOD=1,SILTNO=1,LTYPE=D64BWM;
<CRC7LINK:LSNAM=x622LS,LCOD=2,SILTNO=3,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=x622LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=x622LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=2,OST=MBL;
<CONFDIU:LTG=0-3,DIU=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=3,OST=MBL;
<CONFDIU:LTG=0-3,DIU=3,OST=ACT;
<CANTRDAT:TGNO=x622c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=x622c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S1NUC1,LTGIC=0-3,LCIC=2-16,LTGOG=0-1,LCOG=0-16,TYPE=MUX;
<ACTNUC:NUC=S1NUC1;
<CRNUC:NUC=S3NUC1,LTGIC=0-3,LCIC=3-16,LTGOG=0-1,LCOG=1-16,TYPE=MUX;
<ACTNUC:NUC=S3NUC1;

/
<CRC7DP:DPC=0-5-2,NETIND=INAT0,PRD=TAC4LS&x622LS,LSK=0;
<CONFC7DP:DPC=0-5-2,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-2,NETIND=INAT0;
<CRTRUNK:TGNO=TAC4C,LTG=0-4,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=TAC4C,LTG=0-4,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=TAC4LS,LCOD=1,SILTNO=2,LTYPE=D64BWM;
<CRC7LINK:LSNAM=TAC4LS,LCOD=2,SILTNO=4,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=TAC4LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=TAC4LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=2,OST=MBL;
<CONFDIU:LTG=0-4,DIU=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=3,OST=MBL;
<CONFDIU:LTG=0-4,DIU=3,OST=ACT;
<CANTRDAT:TGNO=TAC4c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=TAC4c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S2NUC1,LTGIC=0-4,LCIC=2-16,LTGOG=0-1,LCOG=1-0,TYPE=MUX;
<ACTNUC:NUC=S2NUC1;
<CRNUC:NUC=S4NUC1,LTGIC=0-4,LCIC=3-16,LTGOG=0-1,LCOG=2-0,TYPE=MUX;
<ACTNUC:NUC=S4NUC1;
<RESETCFOPT;
<ENDFILE;

SN2013EU13SN_0001
93
© 2002 Siemens AG
Siemens Appendix: Administration of the SS7 Network in EWSD Classic

Data in TAC4
<CMDFILE;
<SETCFOPT:ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;

<CRC7OP:SPC=0-5-2,NETIND=INAT0,STPI=STP;

<CRTGRP:TGNO=x622C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=x622LS,SPC=0-5-0,NETIND=INAT0,LSK=15;
<CRTGRP:TGNO=x566C,OPMODE=IC,GCOS=CCSLGRP;
<CRC7LSET:LSNAM=x566LS,SPC=0-5-1,NETIND=INAT0,LSK=15;

<CRC7DP:DPC=0-5-0,NETIND=INAT0,PRD=x622LS,LSK=0;
<CONFC7DP:DPC=0-5-0,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-0,NETIND=INAT0;
<CRTRUNK:TGNO=x622C,LTG=0-4,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=x622C,LTG=0-4,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=x622LS,LCOD=1,SILTNO=1,LTYPE=D64BWM;
<CRC7LINK:LSNAM=x622LS,LCOD=2,SILTNO=3,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=x622LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=x622LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=2,OST=MBL;
<CONFDIU:LTG=0-4,DIU=2,OST=ACT;
<CONFDIU:LTG=0-4,DIU=3,OST=MBL;
<CONFDIU:LTG=0-4,DIU=3,OST=ACT;
<CANTRDAT:TGNO=x622c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=x622c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S1NUC1,LTGIC=0-4,LCIC=2-16,LTGOG=0-1,LCOG=0-16,TYPE=MUX;
<ACTNUC:NUC=S1NUC1;
<CRNUC:NUC=S3NUC1,LTGIC=0-4,LCIC=3-16,LTGOG=0-1,LCOG=1-16,TYPE=MUX;
<ACTNUC:NUC=S3NUC1;

/
<CRC7DP:DPC=0-5-1,NETIND=INAT0,PRD=x566LS,LSK=0;
<CONFC7DP:DPC=0-5-1,NETIND=INAT0,OST=ACT;
<CRC7USER:USNAME=ISUP,DPC=0-5-1,NETIND=INAT0;
<CRTRUNK:TGNO=x566C,LTG=0-3,LC=2-16,LCOS=DIGSIG8;
<CRTRUNK:TGNO=x566C,LTG=0-3,LC=3-16,LCOS=DIGSIG8;
<CRC7LINK:LSNAM=x566LS,LCOD=1,SILTNO=2,LTYPE=D64BWM;
<CRC7LINK:LSNAM=x566LS,LCOD=2,SILTNO=4,LTYPE=D64BWM;
<CONFC7LINK:LSNAM=x566LS,LCOD=1,OST=ACT;
<CONFC7LINK:LSNAM=x566LS,LCOD=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=2,OST=MBL;
<CONFDIU:LTG=0-3,DIU=2,OST=ACT;
<CONFDIU:LTG=0-3,DIU=3,OST=MBL;
<CONFDIU:LTG=0-3,DIU=3,OST=ACT;
<CANTRDAT:TGNO=x566c,LNO=1,BLK=ADMIN;
<CANTRDAT:TGNO=x566c,LNO=2,BLK=ADMIN;
<CRNUC:NUC=S2NUC1,LTGIC=0-3,LCIC=2-16,LTGOG=0-1,LCOG=1-0,TYPE=MUX;
<ACTNUC:NUC=S2NUC1;
<CRNUC:NUC=S4NUC1,LTGIC=0-3,LCIC=3-16,LTGOG=0-1,LCOG=2-0,TYPE=MUX;
<ACTNUC:NUC=S4NUC1;
<RESETCFOPT;
<ENDFILE;

94 SN2013EU13SN_0001
© 2002 Siemens AG