Practical Problems and Experiences PDF
Practical Problems and Experiences PDF
Practical Problems and Experiences PDF
3. When cutting pipe that coated internally with enamel or glass, delicate core should be taken to avoid
cracking or chipping the internal coating. What kind of tool that should never be used for cutting such
pipe?
4. What is that tool used for expanding the ends of lead pipe?
5. What is that valve recommended for installations that call for throttling?
6. What is the minimum length of time before a jointed plastic pipe be subjected to pressure test?
7. What will be the maximum water service pressure at the point where the building distribution system
begins?
9. Is the Revised Plumbing Code of the Philippines allows Wooden type of Septic tank?
10. What device to be installed for commercial or Industrial Special waste when liquid wastes
containing excessive amounts of grease,garbage, flammable wastes, sand, or other ingredients which
may affect the operation of a private sewage disposal system.
a. Receptor b. Interceptor c. Septic Tank d. None of the above
11. What test shall be applied to any drainage and vent system?
13, In how many minutes shall a water or air be on piping system before inspection for both water test
and air test for any plumbing system?
14. When a water pipe crosses a sewer or drainage piping constructed on a clay materials, where shall
our water pipe be located?
a. 0.30m below a sewer or drainage pipe c. 0.30m above a sewer or drainage pipe
b. 0.30m parallel to the sewer or drainage pipe d. None of the above
15. All indirect waste from food equipments must be separated by ______when discharging it to
drainage system?
a. air break b. air gap c. full air break d. full air gap
16. All indirect waste from sterile equipments shall be drained through an________.
a. air break b. air gap c. full air break d. full air gap
17. An adjustable plumbing tool for gripping hexagonal nuts, with an adjusting screw in the head of the
implement.
18. A plumbing tool used to tighten connections in deeply recessed places that are very hard to get at
normally.
19. An approved tank or pit that collects sewage or liquid waste and which is located below the normal
grade of the gravity plumbing system and that requires mechanical means to be emptied is called a:
28. Regardless of the type of heater all energy source must be turn off before attempting to;
34. The use of a circuit vent and a loop vent eliminates the need for:
36. A hanger used to support a vertical pipe that penetrates a floor is called a:
38. The most common distance between the hot and cold roughing in on a sink is:
a. 4” b. 6” c. 8 “ d. 3”
40. To minimize water retention in Whirlpool bathtubs pump and circulating piping must be:
42. What is the minimum clearance from invert elevation of inlet pipe to a sump pit from the starting
level of pumping operation of sump pit?
43. For the hot and cold water distribution system, on what side should the hot water supply be placed
in combination fittings?
44. What is the shape for the signage for women's comfort room in order to aid visually impaired
women readilty determine whether a washroom is for men or women?
45. Drainage piping serving fixtures located below the crown level of the main sewer shall discharge into
an approved water tight
46. In the water test of the entire plumbing system all openings should be tightly closed except at
47. Where practical, all pipes from fixtures shall be run in what direction with respect to the nearest wall
or building line?
A.perpendicular B.across C.offset D.parallel
48. What is the type of Siamese connection that all 125-millimeter dry standpipes shall be equipped
with?
49. What installation standard is followed in joining plastic pipe and fittings by solvent cement?
50. Which of the following is the primary basics for sizing vertical rainwater piping in the Revised
National Plumbing Code?
53. How far must the pipe must go into the fitting socket in order to ensure that the joint holds?
54.How do you know when the copper fitting and tubing are hot enough to apply solder?
A.Tub Spout
B.Shower valve
C.Drain
D.Shower Head
A.Left Side
B.Right Side
C.Center
D.Bottom
A.Spud washer
B.Wax Ring
C.O-Ring
D.Lock Washer
A.Red
B.Yellow
C.Blue
D.Orange
60. What substance is not permitted in solder which is used for water supply pipes?
A.Tin B.Brass C.Lead D.Steel
61. If a Plumbing Plan scaled as 1: 200 , then s 1 cm in the plan is equal to____ in actual ?
62. If a Plumbing Plan scaled as 1: 1, 000 , then 2 cm in the plan is equal to____ in actual ?
63. If a Plumbing Plan scaled as 1: 50 , then 400 square cm in the plan is equal to____ in actual ?
A.100 sq. ft . B.100 sq mts C. 200 sq. mts D.200 sq. ft.
64. . If a Plumbing Plan scaled as 1: 50 , then 20 cm x 40cm cistern plan is equal to____ cubic mts in
actual ? Assume 2.00 mts actual depth of the cistern.
65. . If a Plumbing Plan scaled as 1: 10,000 , then 10 cm x 20cm catchment area in the plan is equal
to____ cubic mts of rainfall in actual for every hour ? Assume 100 mm/hr rain intensity.
66. According to BP 344 Accessible toilet compartments shall have the following a minimum area of
____.
67. . According to BP 344 A turning space of ____ sq. m with a minimum dimension of
_____mm for wheelchair users shall be provided outside water closet cubicles.
69. According to BP 344 the maximum height of toilet seat for persons with
disabilities is _______?
70. According to BP 344 the maximum height of lavatory for persons with
disabilities is _______with knee recess of 0.60m-0.70m depth of 0.50m?
a. 700 mm b. 800 mm c. 600 mm d. None of the above
89. ________ is the result of vapor bubbles imploding. This occurs when the amount of water flowing
into the pump is restricted or blocked.
90. Net Positive Suction Head Available must always be lesser than Net Positive Suction Head Required
by pump to avoid air related problems of pump impeller.
91. ________ plumber- has served his apprenticeship and is competent to perform
the tasks of installing and repairing plumbing.
92. ___________- water drained from lavatories, sink, laundry trays and showers;
contains minor pollutants.
99. device for regulating the supply of water in a flush tank by means of a hollow floating ball. also called
float valve
g. A.ball cock B.flushometer valve C.water hammer D.backsplash
100. The pipe from the public water main or source of water supply to the building served
A.SERVICE PIPE B.MAIN SERVICE PIPE C.DISTRIBUTION PIPE d. None of the above.
h.