Type 1066 On-Off Piston Rotary Actuator With H Mounting Adaptation
Type 1066 On-Off Piston Rotary Actuator With H Mounting Adaptation
Introduction
Scope of Manual
This instruction manusl provides installation. operatIm
maintenanca, and parts ordering information for the Type
1066 orroff piston rotary actuator with H mounting (see
figure 1). Instructions for accessories are included in
separate instruction manuals.
Specifications
Installation
Specifications are shown in table 1 fw Type 1066
actuators Some specifications for a given actuator as it If it is necessary to mount the actuator on a valve body or
originally comes from the factory are stamped on a other equipment, perform the actuator mounting pro
nameplate (figure 2) attached to the actuator. cedure.
L
Type 1066 With H Mounting
Table 1. Specifications
STROKING
TIME Dependent on actuator size, rota- APPROXIMATE Size 20: 32 (15)
tion, and supply pressure. It [kp) Size 75: 85 (38)
WEIGHTS,POUNDS
stroking time is critical, consult
your Fisher sales office or sales AOGITIONAL For construction materials, see
representative SPECIFICATIONS the parts list
Actuator Mounting
Use the following steps to connect the actuator to a valve
body or other equipment. Key numbers are shown in
figure 6. Mounting dimensions are shown in figure 3.
Note
2
Type 1066 With H Mounting
September 1984
Errata Sheet
for
0 In the parts list on pages 8, 9, and 10, add the following parts:
-KEY DESCRlPTION
- PAKT NUMBER
1 Housing, cast iron
Size 27 48A4404 X012
3 Piston, aluminum
Size 27 28A4409 X012
2
-KEY DESCRIPTION PART NUMBER
Size 75
Standard Hub Construction (1)
l-1/8 inch (28.6 mm) output shaft diameter MA4485 X012
l-l/Z inch (38.1 mm) output shaft diameter 38A4486 X012
17* O-Ring
Size 27
Nitrile ID4446 X0052
Fluoroelastomer ID4446 X0012
1. Use this hub construction for mounting positions 2 and 4 for clockwise to
close equipment action, and for mounting positions 1 and 3 for
counterclockwise to close equipment action. (Refer to figure 5 in the
instruction manual for mounting positions.)
2. Use this hub constructiw for mounting positions 1 and 3 for clockwise ta
close equipment action, and for mounting positions 2 and 4 for counter-
clockwise to close equipment action. (Refer to figure 5 in the insrruc-
tlon manual for mounting positions.)
-KEY --DESCRlPTION PART NUMBER
18* O-Ring
Size 27
Nitri.le 15A8508 X012
Fluoroelastomer 15A8508 X022
34* O-Ring
Size 27
Nitrile lV1157 06992
Fluoroelastomer lV1157 x0012
41 Adaptor, steel
(Use with switches only - see figure 7
in manual)
Size 27
7/8-inch (22.2 m) output shaft diameter 20A4515 X012
l-1/8 inch (28.6 mm) output shaft diameter 28A4516 x012
5
Type 1066 With H Mounting
"
I7
+!
+t
Pw,cw
3
Type 1066 With H Mounting
Loading Connections
1. Type 1066 actuators should have either a loading
solenoid, a four-way switching valve, or two threeway
switching valves connected to the i/4-inch NPT pressure
connections located at the top and bottom of the actuator
cylinder.
Adjustment
Figure 4. Center of Gravity Dimensions Key numbers referenced in this section are shown in
figure 6.
4
Type 1066 With H Mounting
Principle of Operation
Maintenance
1. Disconnect the pressure tubing from the actuator. 4. Remove the cap screws (key 20) from the operated
Then. remove the cap screws (key 16), the flat washers shafl end of the actuator. Then, remove the actuator from
(key 15). the cylinder cover(key2), and thecylinder(key6). the operated equipment.
2. Inspect the O-ring(key 17) and the gaskets(key33) 5. With the actuator at the top of its stroke, mark the
for nicks or flat spots that might cause leakage. Replace orientation of the flats on the output shaft end of the hub
either part as necessary (key6) with respect to the actuator housing (keyl). Also,
mark the orientation of the travel indicator (key 22) with
Note respect to the travel indicator scale (key 21). These
markings are used during reassembly to allow for proper
If replacing the Bring (key 17) or gaskets output shaft positioning. With the output shaft, housing,
(key 33) is the only maintenance neces- travel indicator, and travel indicator scale properly
saw, skip the remaining steps and re marked, remove the retaining ring (key40) and the travel
assemble the actuator as described in step indicator. Then, remove both retaining rings (key 39).
25 of this procedure. Unscrew the remaining cap screws (key 20) and remove
both travel indicatorscales(key21) from both sidesofthe
3. Remove the limit switch, position switch, or other actuator. Mark the orientation of each travel indicator
accessories, if used. Refer to the accessory instruction scale with respect to the actuator housing before
manual for instructions. removing it.
Type 1066 With H Mounting
6. Remove the bearing(key4) andthen removethe hub 21. Slide each travel indicator scale (key 21) onto the
(key6) from the housing(key1). InspecttheDrings(keys hub on each side of the actuator. When installing each _
18 and 34) for wear and damage. Replace the Orings if travel indicator scale, make sure that the markings on
necessary each scale and housing that were made in step5 of this
procedure are oriented correctly.
7. Lift the piston(key3) with attached piston rod(key5)
and attached lever and bearing assembly(key 10) out of 22. Install each retaining ring (key 39) onto the hub on
the actuator housing. each side of the actuator.
8. Unscrew the cap screw (key 19). and remove the 23. With the actuator at the top of its stroke, slide the
sealing washer (key 11) and the piston from the piston travel indicator(key22) ontotheendofthe hubsothatthe
rod. For size 20 actuators, a fiat washer(key23) will also markings that were made in step 5 of this procedure are
be removed with these parts. oriented correctly (travel indicator to travel indicator
scale). Secure the travel indicator to the hub with the
9. Remove one of the two E-rings (key 14) and then retaining ring (key 40).
remove the pin (key 9). Separate the lever and bearing
assembly from the piston rod. 24. Slide the actuator onto the equipment operating
shaft and secure it to the mounting bracket in the desired
10. Inspect the lever and bearing assembly for ax- position with the cap screws (key 20). Install the cap
cessive wear. Replace the assembly if necessary screws(key20) on bothsidesoftheactuator housingand
torque them to 16 foot-pounds (25 N-m) for size 20
11. Reconnect the lever and bearing assembly to the actuators and to 75 foot-pounds (102 N.m) for size 75
piston rod with the pin. Secure the pin with the E-ring. actuators.
12. Apply Lubriplate MAG-1 or equivalent lubricant (key 25. Apply Lubriplate MAG-1 or equivalent lubricant (key
35) to the cap screw (key 19) and the C-ring (key 17) as 35) to the wall of the cylinder as shown in figure 6. Then,
shown in figure 6. install the cylinder and cylinder cover and secure them to
theactuatorwiththecapscrews(key16)andflatwashers
13. Attach the piston to the piston rod with the cap (key 15). Torque the cap screws to 30 foot-pounds (41
screw (key 19) and sealing washer (key 11). Torque the N-m) for size 20 actuators and to 75 foot-pounds (102 _
cap screw to 60 foot-pounds (81 N-m) for size 20 N-m) for size 75 actuators.
actuators and to 130 foot-pounds (176 N.m) for size 75
actuators. For size 20 actuators, a flat washer (key 23) is 26. Connect the pressure tubing to the actuator. Then,
also installed with these parts. install the limit switch, position switch, or other acces-
sories, if used. Refer to the accessory instruction manual
14. Lower the piston rod assembly into the actuator for instructions.
housing.
27. Perform the adjustment procedure before placing
15. Apply Lubriplate MAG-1 or equivalent lubricant (key the actuator into operation.
35) to the CHing (key 34) as shown in figure 6.
19. Apply Lubriplate MAG-1 or equivalent lubricant (key l Isolate the valve or other operated
35) to the outer surface of the bearing (key 4) and to the equipment from the process,
Bring (key 18) as shown in figure 6. l Release process pressure, and
20. Install the bearing into the housing. l Vent the actuator loading pressure. 4
Type 1066 With H Mounting
Use the following procedures along with figure 6 for key 11. Slide the actuator in the desired position (1,2,3. or4)
number references to convert from style A to style 8, or onto the equipment operating shaft and secure it to the
vice versa, or to change the mounting position. mounting bracket with the cap screws(key20). Install the
capscrews(key20) on both sidesoftheactuatorhousing
Changing Styles and torque them to 18 foot-pounds(25 Nom) for size 20
actuators and to 75 foot-pounds (102 N-m) for size 75
1. Disconnect the pressure tubing from the actuator. actuators.
Then, remove the limit switch, position switch, or other
accessories, if used. Refer to the accessory instruction 12. Connect the pressure tubing to the actuator. Then,
manual for instructions. install the limit switch, position switch, or other acces-
sories, if used. Refer to the accessory instruction manual
2. Remove the cap screws (key 20) from the operated for instructions.
shaft end of the actuator. Then, remove the actuator from
the operated equipment. 13. Perform the adjustment procedure before placing
the actuator into operation.
3. Using a convenient air supply with 120 psig (8.3 bar)
maximum pressure. position the actuator piston at the top
of its stroke. Remove the retaining ring (key 40) and the Changing Positions
travelindicator(key22). Then, unscrewtheremainingcap
screws (key 20).
Note
4. Rotate the actuator housing 180 degrees while main-
taining the appropriate position (1, 2, 3. or 4). If changing from mounting position 1 to
position3 or from position2 toposition4. or
5. The style change results in a 90-degree shift in flat vice versa, disregard steps 1 through 11
orientation on the actuator output shaft end of the hub and proceed as follows. Remove the cap
(key6). If this shift can be accommodated conveniently by screws (key 20) from the operated shaft
using a different coupling or by reorienting the coupling end of the actuator, remove the actuator
on the operated equipment shaft, skip steps 6 through 9 from the operated equipment, and then
and proceed with step 10 of this procedure. Otherwise, rotate the actuator to the appropriate
proceed with the following step. position. Slide the actuator in the desired
position onto the equipment operating
6. Remove both retaining rings(key39) and both travel shaft and secure it to the mounting bracket
indicator scales (key 21) from both sides of the actuator. with the cap screws (key 20). Torque the
Then, remove the bearing (key 4) and the hub from the cap screws to18 foot-pounds (25 Nom) for
housing (key 1). size 20 actuators and to 75 foot-pounds
(102 N-m) for size 75 actuators. Perform
7. Before sliding the hub into the lever and bearing the adjustment procedure before placing
assembly, make sure that the milled flats on the output the actuator into operation.
shaft end of the hub are positioned appropriately. The
flats may be positioned either parallel with or perpep
dicular to the actuator cylinder(key8) when the actuator
is at the top of its stroke. If necessary, flip the hub enct 1. Disconnect the pressure tubing from the actuator.
over-end to obtain proper flat orientation. With the hub Then, remove the limit switch, position switch, or other
positioned appropriately, slide the hub into the housing accessories, if used. Refer to the accessory instructlon
and through the lever and bearing assembly. manual for instructions.
8. Apply Lubriplate MAG-1 or equivalent lubricant (key 2. Using a convenient air supply with 120 psig (8.3 bar)
35) to the outersurfaceofthe bearing(key4). Then, install maximum pressure, position theactuatorpiston at the top
the bearing into the housing. of its stroke. Remove the cap screws (key 20) from the
operated shaft end of the actuator. Then, remove the
9. Slide each travel indicator scale (key 21) and each actuator from the operated equipment.
retaining ring (key 39) onto the hub on each side of the
actuator. 3. Remove the retaining ring (key 40), the travel
indicator(key22), and bothretainingrings(key39). Then,
10. With the actuator at the top of its stroke, slide the unscrew the remaining cap screws (key 20) and remove
travel indicator (key 22) onto the end of the hub and both travel indicatorscales(key21) from both sidesofthe
position it so that it can show the proper position of the actuator.
operated equipment when the operated equipment is in
the open position. Secure the travel indicator to the hub 4. Remove the bearing(key4), and then remove the hub
with the retaining ring (key 40). (key 6) from the housing (key 1).
Type 1066 With H Mounting (FISHER”)
5. Rotate the actuator housing either 90 degrees 9. Maintaining the desired mounting position, slide the
clockwise or90 degrees counterclockwise as desired to actuator onto the equipment operating shaft and secure it
obtain the appropriate mounting position. to the mounting bracket with the cap screws (key 20). -
Install the cap screws (key 20) on both sides of the
6. Before sliding the hub into the lever and bearing actuator housing and torque them to 16 foot-pounds (25
assembly(key lo), make Sure that the milled fiats on the Nom) for size 20 actuators and to 75 foot-pounds (102
output shaft end of the hub are positioned appropriately. Nom) for size 75 actuators.
The flats may be positioned either parallel with or
perpendicular to the actuator cylinder (key 8) when the 10. Connect the pressure tubing to the actuator. Then,
actuator is at the topof its stroke. With the hub positioned install the limit switch, position switch, or other axes-
appropriately, slide the hub into the housing and through so&s, if used. Refer to the accessory instruction manual
the lever and bearing assembly. for instructions.
7. Apply Lubriplate MAG-1 or equivalent lubricant (key 11. Perform the adjustment procedure before placing
35) to theoutersurfaceofthe bearing(key4). Then, install the actuator into ooeration.
the bearing into the housing.
6. Slide each travel indicator scale (key 21) and each Parts Ordering
retaining ring (key 39) onto the hub on each side of the
actuator. Then, with the actuator at the top of its stroke, When corresponding with your Fisher sales office or
slide the travel indicator(key22) onto the end of the hub sales representative about this equipment, refer to the
and position it so that it can show the proper position of serial number found on the actuator nameplate (figure 2
the operated equipment when the operated equipment is and key 27, figure 6). Also, specify the complete ll-
in the open position. Secure the travel indicator to the hub character part number from the following parts list when
with the retaining ring (key 40). ordering replacement parts.
Parts List
6
Type 1066 With H Mounting
.
7-
Figure 7. Adaptor(Key41) for Type 1066 Actuators
(Shown with Type 304 Position Switch)