Cooling water system in hydropower

Hydropower plants bring a major contribution to the sustainable energy supply. To maintain a high degree
in operation safety, one must pay attention to the cooling that hydropower generators need. Turbines' and
generators ‘bearings lubrication systems need cooling, the oil-filled transformers need cooling and
turbines' seals need cold-water. So, a hydropower plant must incorporate an efficient cooling water
system. In order to work properly, such system needs to ensure the filtration of the incoming water. In
some cases, a secondary function like supplying water for firefighting is added to the system.
Due to operation safety, the cooling water system is an important issue within any Hydro-Power Plant
(HPP).

SOURCES OF COOLING WATER


Most hydroelectric generating sets need cooling water for bearings, generator air coolers and governor oil
coolers. The basic requirement is for a supply of clean water in sufficient quantities. The water should be
available when the set is running and should be shut off when it is stopped.
The water can be:
• pumped from the tailrace;
• tapped off the penstock;
• supplied by an auxiliary turbine;
• taken from the turbine cover.

The consumers that need cooling water are the following equipment and lubrication systems:
 air-water heat exchangers related to hydro generators
 oil-water heat exchangers related to bearings
1. a heavy-duty thrust bearing in generator
2. a guide bearing in the generator
3. guide bearing is attached to the hydraulic turbine;
 oil-water heat exchangers related to step-up transformers
 oil-water heat exchangers related to speed governors;
 coolers of the turbine main shaft axial seals;
 air-water heat exchangers related to the HVAC system of the powerhouse.

Tailrace
Pumping from the tailrace requires two pumps per set (one duty and one standby) and a reliable power
supply. It is expensive in terms of the power consumption of the pumps and the piping installation.
Unless the water is very clean, self-cleaning filters will be required. If the station is on a river that carries
large amounts of debris during floods, blockage of the pump intake filters is a potential problem.

Penstock
Tapping cooling water off the penstock is the best option for low head stations. It is important to locate
the tapping point on the side of the penstock; if it is at the top, it tends to get blocked by floating debris
and if it is on the bottom, (often done because it is convenient to tap off the penstock drain), it can
ingest silt, stones and other debris.
On medium and high head stations, careful design is required. The penstock pressure is greater than the
cooling system can withstand, so some means of pressure reduction is required. At medium heads (<30
m) pressure reducing valves or orifices can be used and provide a very satisfactory solution. At higher
heads, the energy dissipation in the valve or orifice will be high and cavitation damage and erosion can
be expected. If the water is silty, erosion rates can be very high. This can lead to failure of the valve
which imposes excessive pressures on the cooling system. So the extra complication of a pressure relief
valve is needed.