02 NetNumen U31 Software Installation - 54P
02 NetNumen U31 Software Installation - 54P
02 NetNumen U31 Software Installation - 54P
Installation
Contents
Overview
Environment Verification Before Installation
Installing the NetNumen U31 Server Software
Uninstalling the NetNumen U31 Server Software
2
NetNumen U31 Software Architecture
Software environment
Operating system
Server: Linux
Client: Windows XP, Windows Vista, Windows 7 pro, Windows 2000, Windows
Server 2003, and Windows Server 2008, Unix, Linux, Aix, Solaris.
Database
Oracle 11g Enterprise Edition, and Sybase IQ.
Network hardware
The network that connects the NetNumen U31, RAT equipment, and the
upper-level OMC must operate properly. If remote maintenance is required,
network access must be available.
Overview
Environment Verification Before Installation
Installing the NetNumen U31 Server Software
Uninstalling the NetNumen U31 Server Software
7
Verifying the System Time and Time Zone
Check Item
Parameter Description
DEPLOYMENT Whether the database and the application are at the same server.
OSUSER User on the server where the database is located.
OSPASS Password of the user on the server where the database is located.
SYSTEMPW Password of the system user.
SID of the database, not including IP. If the database cannot be connected,
DBSID the local network service name of the database should be configured. The
database connection ID used in this tool is dbsid_dbip.
Whether dual servers are configured. This parameter is mandatory.
HOSTENV SINGLE means one server is configured. DOUBLE means two servers are
configured.
After installation or before upgrading, this parameter must be modified to
the directory where the software package is installed, that is, the parent
EMSHOME
directory of the ums-server directory on the EMS. Do not modify this
parameter before installation.
Overview
Environment Verification Before Installation
Installing the NetNumen U31 Server Software
Uninstalling the NetNumen U31 Server Software
16
Installing the NetNumen U31 Server Software
Steps :
1.Log in to the operating system as the root user, and then
create the omc user by running the following commands.
Specify omc as the owner of the /export/home/version/ directory.
# chown -R omc /export/home/version/
Specify other as the group of the /export/home/version/ directory.
# chgrp -R other /export/home/version/
4.Log in to the Linux operating system as the omc user, and then
run the following command to enter the software installation
directory.
$ cd /export/home/version/U31V12.15.30
5.Enter the ./setup.sh command and press Enter key to start the
installation.
If the folder /netnumen/ems does not exist, the message will be shown.
Click Yes.
For a blade server, the ICM must be independently deployed. Therefore, the
nodes under MOSS ICM cannot be selected. The products supported by a
blade server include GSM, GUT NAF, assets database interface, UMTS, LTE
FDD, TE-LTE, NAF LTE, NAF LTE DB, and NAF ITFPM.
For the configuration of SyBaseIQ DB config, history alarms can only be saved in
SybaseIQ raw device. The database type is SybaseIQ, Fill in the SybaseIQ service
name according to the actually set service name.
19.Verify that the Detection Result for all items are Pass, and then
click Next
21.After the file unzipping and copying process is completed, click Next.
A message is displayed, asking whether to execute necessary SQL scripts.
22.Click Yes.
Installation Finished
Console starting
Start it in the master server side. Directly execute console.sh under the
ums-server directory, and you will be prompted to enter the
corresponding console ID. If nothing is entered and click Enter directly,
all consoles will be started. To start one console, please enter console2,
console3….
Overview
Environment Verification Before Installation
Installing the NetNumen U31 Server Software
Uninstalling the NetNumen U31 Server
Software
50
Uninstalling the NetNumen U31 Server
Software
Steps:
1.Log in to the NetNumen U31 server as the root user.
2.Execute the following commands to change the current
directory to uif in the installation path (for example,
/home/omc/netnumen/ems) of the server software and start
uninstalling the server software:
# cd /home/omc/netnumen/ems/uif
# ./uninstalltool.sh