Domestic Cooking Appliances Burning Gas: Part 1-1: Safety - General
Domestic Cooking Appliances Burning Gas: Part 1-1: Safety - General
Domestic Cooking Appliances Burning Gas: Part 1-1: Safety - General
+A1:2010
Domestic cooking
appliances burning gas
Part 1-1: Safety — General
ICS 97.040.20
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
National foreword
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
© BSI 2010
English Version
Appareils de cuisson domestiques utilisant les Haushalt-Kochgeräte für gasförmige Brennstoffe - Teil 1-1:
combustibles gazeux - Partie 1-1: Sécurité - Généralités Sicherheit - Allgemeines
This European Standard was approved by CEN on 11 July 2008 and includes Amendment 1 approved by CEN on 29 May 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
www.bzfxw.com
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 30-1-1:2008+A1:2010: E
worldwide for CEN national Members.
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Contents Page
Foreword ..............................................................................................................................................................5
1 Scope ......................................................................................................................................................6
2 Normative references ............................................................................................................................8
3 Terms and definitions ...........................................................................................................................9
3.1 General terms and definitions ..............................................................................................................9
3.2 Terms and definitions relating to the appliance .................................................................................9
3.3 Terms and definitions relating to gases and pressures ................................................................. 10
3.3.1 Terms and definitions relating to gases ........................................................................................... 10
3.3.2 Terms and definitions relating to pressures .................................................................................... 12
3.4 Terms and definitions relating to the parts of the appliance ......................................................... 12
3.4.1 Burners ................................................................................................................................................ 12
3.4.2 Auxiliary equipment, control devices ............................................................................................... 14
3.4.3 Other components .............................................................................................................................. 16
3.5 Terms and definitions relating to operation .................................................................................... 17
4 Classification....................................................................................................................................... 19
4.1 Classification of gases ....................................................................................................................... 19
4.2 Categories of appliances ................................................................................................................... 20
4.2.1 General ................................................................................................................................................. 20
www.bzfxw.com
4.2.2 Category I ............................................................................................................................................ 20
4.2.3 Category II ........................................................................................................................................... 21
4.2.4 Category III .......................................................................................................................................... 21
4.3 Classes of appliances (see Figure 2) ................................................................................................ 22
5 Constructional requirements............................................................................................................. 22
5.1 General ................................................................................................................................................. 22
5.1.1 Conversion to different gases ........................................................................................................... 22
5.1.2 Materials .............................................................................................................................................. 23
5.1.3 Ease of cleaning and maintenance ................................................................................................... 25
5.1.4 Strength ............................................................................................................................................... 25
5.1.5 Soundness of the gas circuit assembly ........................................................................................... 26
5.1.6 Connections ........................................................................................................................................ 26
5.1.7 Movable appliances ............................................................................................................................ 28
5.1.8 Fixing or stability of appliances ........................................................................................................ 28
5.1.9 Additional components ...................................................................................................................... 28
5.1.10 Safety of operation in the event of fluctuation, interruption and restoration of the auxiliary
energy .................................................................................................................................................. 28
5.1.11 Electrical safety of appliances and immunity to electromagnetic phenomena ........................... 28
5.2 Special requirements ......................................................................................................................... 29
5.2.1 Taps ...................................................................................................................................................... 29
5.2.2 Control handles................................................................................................................................... 30
5.2.3 Injectors and adjusters ...................................................................................................................... 32
5.2.4 Oven thermostats ............................................................................................................................... 33
5.2.5 Ignition systems.................................................................................................................................. 34
5.2.6 Flame supervision devices ................................................................................................................ 34
5.2.7 Regulators ........................................................................................................................................... 34
5.2.8 Hotplates .............................................................................................................................................. 35
5.2.9 Ovens and grills .................................................................................................................................. 37
5.2.10 Cylinder compartment ........................................................................................................................ 40
5.2.11 Appliances with a cooling fan ........................................................................................................... 40
5.2.12 Accumulation of un-burnt gas........................................................................................................... 41
5.2.13 Food hygiene in time controlled ovens ............................................................................................ 42
--`,,,,`,,`,,```,`,,`,``,`,,`
2
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
5.3 Additional requirements for appliances having one or more burners that are capable of
remote operation ................................................................................................................................. 42
5.3.1 Application ........................................................................................................................................... 42
5.3.2 General ................................................................................................................................................. 42
5.3.3 Remote operation (type 1) .................................................................................................................. 43
5.3.4 Remote operation (type 2) .................................................................................................................. 43
6 Performance requirements ................................................................................................................. 43
6.1 General ................................................................................................................................................. 43
6.1.1 Soundness ........................................................................................................................................... 43
6.1.2 Obtaining the input rates .................................................................................................................... 43
6.1.3 Flame supervision devices ................................................................................................................. 44
6.1.4 Safety of operation .............................................................................................................................. 45
6.1.5 Heating.................................................................................................................................................. 45
6.1.6 Temperature of the LPG cylinder and its compartment .................................................................. 48
6.1.7 Total input of the appliance ................................................................................................................ 49
6.1.8 Regulator performance ....................................................................................................................... 49
6.1.9 Appliances with a cooling fan ............................................................................................................ 49
6.1.10 Safety in the event of failure of the oven thermostat ...................................................................... 52
6.2 Special requirements for hotplates ................................................................................................... 54
6.2.1 Ignition, cross-lighting and flame stability ....................................................................................... 54
6.2.2 Combustion .......................................................................................................................................... 55
6.3 Special requirements for ovens and grills ........................................................................................ 55
6.3.1 Ignition, cross-lighting and flame stability ....................................................................................... 55
6.3.2 Combustion .......................................................................................................................................... 56
7 Test methods ....................................................................................................................................... 56
7.1 General ................................................................................................................................................. 56
7.1.1 Reference and test gases ................................................................................................................... 56
www.bzfxw.com
7.1.2 Test pressures ..................................................................................................................................... 61
7.1.3 Test procedures ................................................................................................................................... 61
7.1.4 Pans ...................................................................................................................................................... 66
7.1.5 Ovens and grill temperatures ............................................................................................................. 67
7.1.6 Appliances having a mains electrical supply ................................................................................... 68
7.1.7 Appliances having one or more multi-ring hotplate burners .......................................................... 68
7.2 Verification of construction characteristics ..................................................................................... 68
7.2.1 Strength ................................................................................................................................................ 68
7.2.2 Strength, stability ................................................................................................................................ 70
7.2.3 Accumulation of un-burnt gas in the appliance ............................................................................... 71
7.2.4 Appliances with a glass lid having a device for shutting off the gas to the hotplate
burners ................................................................................................................................................. 72
7.2.5 Food hygiene in time controlled ovens............................................................................................. 73
7.3 Verification of performance characteristics ..................................................................................... 73
7.3.1 General tests ........................................................................................................................................ 73
7.3.2 Specific tests for hotplates................................................................................................................. 88
7.3.3 Specific tests for ovens and grills ..................................................................................................... 96
8 Marking and instructions .................................................................................................................. 102
8.1 Appliance marking (including any type 2 hand-operated control) ............................................... 102
8.2 Marking of the packaging ................................................................................................................. 103
8.3 Instructions ........................................................................................................................................ 104
8.3.1 General ............................................................................................................................................... 104
8.3.2 Technical instructions ...................................................................................................................... 104
8.3.3 Instructions for use and maintenance ............................................................................................ 106
8.3.4 Instructions for conversion to other gases .................................................................................... 108
Annex A (informative) National situations .................................................................................................... 121
A.1 General ............................................................................................................................................... 121
A.2 Marketing in different countries of the categories listed in the text of the standard ................. 121
A.3 Supply pressures for the appliances (see 7.1.2) ............................................................................ 125
A.4 Particular categories marketed nationally or locally ..................................................................... 127
A.4.1 National distribution.......................................................................................................................... 127
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
3
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
4
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Foreword
This document (EN 30-1-1:2008+A1:2010) has been prepared by Technical Committee CEN/TC 49 “Gas
cooking appliances”, the secretariat of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by January 2011, and conflicting national standards shall be withdrawn at
the latest by January 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ".
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
Part 1-4: Safety — Appliances having one or more burners with an automatic burner control system;
Part 2-2: Rational use of energy — Appliances having forced-convection ovens and/or grills.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
5
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
1 Scope
This European Standard specifies the construction and performance characteristics as well as the
requirements and methods of test for the safety and marking of freestanding and built-in domestic cooking
appliances burning the combustible gases given in 4.1 according to the categories specified in 4.2, referred to
in the text as "appliances".
This European Standard covers the following types of domestic cooking appliances, as defined in Clause 3,
and belonging to the classes defined in 4.3 (see Table 1):
table cookers;
freestanding ovens;
built-in ovens;
griddles;
freestanding cookers;
This European Standard includes requirements covering the electrical safety of equipment incorporated in the
appliance that is associated with the use of gas. It does not include requirements covering the electrical safety
of electrically-heated component parts or their associated equipment1).
a) outdoor appliances;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
d) appliances having covered burners which are not in conformity with the constructional requirements of
5.2.8.2.2;
e) appliances incorporating flame supervision devices and having an automatic ignition device for which the
duration of the ignition attempt is limited by design;
f) appliances equipped with a burner that is periodically ignited and extinguished under the control of an
automatic on/off device;
6
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
1) either for the supply of combustion air or for the evacuation of the products of combustion;
i) appliances having one or more burners that are capable of remote operation (type1 or type 2), unless the
burner(s) concerned are thermostatically controlled oven burners of time-controlled ovens that are
designed for a delayed start without the user being present;
j) appliances incorporating one or more hotplate or grill burners that enable the user to program the cooking
cycle, including the start and/or the end of the cycle."
This European Standard does not cover the requirements relating to third family gas cylinders, their regulators
and their connection.
Table 1 — Three-language table of the names of the different types of domestic cooking appliances
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
- Tables de cuisson isolées - Freistehende Kochteile - Independent hotplates - freestanding
www.bzfxw.com
- Tables de cuisson à encastrer - Eingebaute Kochteile - Independent hotplates - built-in
7
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies, including any amendments. For undated references, the latest
edition of the referenced document (including any amendments) applies.
EN 88-1:2007, Pressure regulators and associated safety devices for gas appliances — Part 1: Pressure
regulators for inlet pressures up to and including 500 mbar
EN 125:1991, Flame supervision devices for gas-burning appliances — Thermo-electric flame supervision
devices
EN 549:1994, Rubber materials for seals and diaphragms for gas appliances and gas equipment
EN 751-1:1996, Sealing materials for metallic threaded joints in contact with 1st, 2nd and 3rd family gases
and hot water — Part 1: Anaerobic jointing compounds
EN 751-2:1996, Sealing materials for metallic threaded joints in contact with 1st, 2nd and 3rd family gases
and hot water — Part 2: Non-hardening jointing compounds
www.bzfxw.com
EN 1106:2001, Manually operated taps for gas burning appliances
EN 10226-1:2004, Pipe threads where pressure tight joints are made on the threads — Part 1: Taper external
threads and parallel internal threads — Dimensions, tolerances and designation
EN 10226-2:2005, Pipe threads where pressure tight joints are made on the threads — Part 2: Taper external
threads and taper internal threads — Dimensions, tolerances and designation
EN 60335-1:2002, Household and similar electrical appliances — Safety — Part 1: General requirements
(IEC 60335-1:2001, modified)
EN 60335-2-6:2003, Household and similar electrical appliances — Safety — Part 2-6: Particular
requirements for stationary cooking ranges, hobs, ovens and similar appliances (IEC 60335-2-6:2002,
modified)
EN 60335-2-102:2006, Household and similar electrical appliances — Safety — Part 2-102: Particular
requirements for gas, oil and solid-fuel burning appliances having electrical connections
(IEC 60335-2-102:2004, modified)
EN 60730-2-1:1997, Automatic electrical controls for household and similar use — Part 2: Particular
requirements for electrical controls for electrical household appliances (IEC 60730-2-1:1989, modified)
EN ISO 228-1:2003, Pipe threads where pressure-tight joints are not made on the threads — Part 1:
Dimensions, tolerances and designation (ISO 228-1:2000)
EN ISO 3166-1:2006, Codes for the representation of names of countries and their subdivisions — Part 1:
Country codes (ISO 3166-1:2006)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
8
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
ISO 15717:1998, Kitchen equipment — Safety requirements and test methods for kitchen cabinets and work
tops
3.1.1
conversion
operation carried out by a specialist on an appliance at the time of a change of gas
3.1.2
removable
can be removed without the aid of a tool
3.1.3
reference conditions
15 °C, 1 013,25 mbar
3.1.4
mechanically fastened
can only be removed with the aid of a tool
3.1.5
www.bzfxw.com
normal maintenance
maintenance carried out by a specialist not including any replacement of parts
3.1.6
soft soldering
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
soldering for which the lowest temperature of the melting range, after application, is less than 450 °C
3.1.7
direct country of destination
country for which the appliance has been certified and which is specified by the manufacturer as the intended
country of destination, such that, at the time of putting the appliance on the market and/or installation, the
appliance needs to be capable of operating, without adjustment or modification, with one of the gases
distributed in the country concerned, at the appropriate supply pressure
NOTE More than one country can be specified if the appliance, in its current state of adjustment, can be used in each
of these countries.
3.1.8
indirect country of destination
country for which the appliance has been certified, but for which, in its present state of adjustment, it is not
suitable; subsequent modification or adjustment is essential in order that it can be utilized safely and correctly
in this country
3.2.1
appliance incorporating a cylinder
appliance functioning in particular with third family gases which includes a compartment for the cylinder
9
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.2.2
freestanding appliance
appliance not normally having direct contact with adjacent furniture or walls
3.2.3
appliance for building-in between two furniture units
appliance which can have its side panels in direct contact with adjacent furniture units
NOTE When installed, the appliance may only be in contact with a single furniture unit.
3.2.4
appliance for building into a furniture unit
appliance intended to be installed in a kitchen cabinet or unit or in a housing located in a wall or under similar
conditions
NOTE For this reason, the appliance may not necessarily have a casing on all sides.
3.2.5
domestic cooking appliance
appliance to be used by private individuals in a domestic dwelling
NOTE This is indicated in the instructions for use and maintenance as well as in the technical instructions.
3.2.6
cooker
cooking appliance comprising:
a hotplate;
www.bzfxw.com
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
one or more ovens with or without a thermostat, having possibly a grill;
possibly a grill
3.2.7
table cooker
cooking appliance intended to rest on a raised support or stand comprising:
a hotplate;
an oven;
possibly a grill
3.2.8
independent hotplate
cooking appliance consisting only of a hotplate
3.2.9
independent hotplate and grill
cooking appliance consisting of hotplate and a grill
3.3.1.1
test gases
gases intended for the verification of the operational characteristics of appliances using combustible gases;
they consist of reference gases and limit gases
10
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
NOTE Table 7 gives the characteristics of reference gases and limit gases.
3.3.1.2
reference gases
test gases with which appliances operate under nominal conditions when they are supplied at the
corresponding normal pressure
3.3.1.3
limit gases
test gases representative of the extreme variations in characteristics of the gases for which the appliances
have been designed
3.3.1.4
relative density
d
ratio of the masses of equal volumes of dry gas and dry air under the same conditions of temperature and
pressure: 15 °C or 0 °C and 1 013,25 mbar
3.3.1.5
calorific value
quantity of heat produced by complete combustion at a constant pressure of 1 013,25 mbar, of a unit volume
or mass of gas, the constituents of the combustible mixture being taken at reference
- the gross calorific value Hs: the water produced by combustion is assumed to be condensed;
NOTE 1
www.bzfxw.com
-the net calorific value Hi: the water produced by combustion is assumed to be in the vapour state.
− either in megajoules per cubic metre (MJ/m3) of dry gas under the reference conditions;
NOTE 2 In this European Standard only the gross calorific value is used
3.3.1.6
Wobbe index
gross Wobbe index Ws; net Wobbe index Wi
ratio of the calorific value of a gas per unit volume and the square root of its relative density under the same
reference conditions. The Wobbe index is said to be gross or net according to whether the calorific value used
is the gross or net calorific value
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
- either in megajoules per cubic metre (MJ/m3) of dry gas under the reference conditions;
3.3.1.7
theoretical air
volume of air necessary for the stoichiometric combustion of a unit volume of gas
11
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.3.2.1
gas supply pressure
p
difference between the static pressure measured at the inlet connection of the appliance in operation and the
atmospheric pressure
2
NOTE The gas supply pressure is expressed in millibar (mbar): 1 mbar = 10 Pa.
3.3.2.2
test pressures
gas pressures used to verify the operational characteristics of appliances using combustible gases. They
consist of normal and limit pressures
2
NOTE 1 The gas pressures used are expressed in millibars (mbar): 1 mbar = 10 Pa.
3.3.2.3
normal pressure
pn
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
pressure under which the appliances operate in nominal conditions, when they are supplied with the
corresponding reference gas
3.3.2.4
limit pressures
maximum pressure: pmax; minimum pressure: pmin
www.bzfxw.com
pressures representative of the extreme variations in the supply conditions
3.3.2.5
pressure couple
combination of two distinct gas distribution pressures applied by reason of the significant difference existing
between the Wobbe indices within a single family or group in which:
the higher pressure corresponds only to gases of low Wobbe index;
3.4.1 Burners
3.4.1.1
burners
component devices that allow the gas to burn
non-aerated burners in which the air for combustion is entrained entirely at the burner outlet;
aerated burners in which part of the air for combustion termed "primary air", is entrained by the gas flow and is mixed
with gas before the burner outlet. The remainder of the air, termed "secondary air" is entrained after the burner outlet.
a gas injector;
12
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.4.1.2
ignition burners
small burners, the flame of which is intended to light a principal burner
3.4.1.3
pilot
ignition burner controlled independently from principal burners
3.4.1.4
principal burners
burners intended to assure a thermal function to the appliance
3.4.1.5
covered burners
hotplate burners for which the pans being heated are screened from direct flame contact by the interposition
of a surface on which they rest
www.bzfxw.com
3.4.1.5.1
non enclosed covered burner
covered burner for which all products of combustion are evacuated directly to atmosphere, e.g. around the
periphery of the plate and which is designed so that partial visibility of the flames is possible in normal
operation
temporary, i.e. designed so that it may also be used as an uncovered burner after removal of the removable plate.
3.4.1.5.2
enclosed covered burner
covered burner having a combustion circuit in which all products of combustion are evacuated to atmosphere
indirectly through a purpose-designed outlet
NOTE The burner may be so enclosed that flames may not be visible during normal operation.
3.4.1.6
uncovered burners
hotplate burners for which the pans being heated are in direct contact with the flames
3.4.1.7
injector
component part that admits the gas into an aerated burner
13
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.4.1.8
multi-ring hotplate burners
hotplate burner assembly having two or more rings of burner ports
NOTE 1 The term ring includes any distribution of burner ports around the central axis of the burner.
3.4.1.8.1
multi-ring hotplate burner with sectional control
multi-ring hotplate burner that is so designed that one or more of its rings of burner ports can be utilised
independently
3.4.1.8.2
multi-ring hotplate burner with simple control
multi-ring hotplate burner that is so designed that its rings of burner ports cannot be utilised independently.
3.4.2.1
auxiliary equipment
all controls and devices that can affect the safety of operation of the gas appliance or the gas part of a
combined gas-electric appliance
EXAMPLES
gas regulators;
3.4.2.2
ignition device
device to ignite one or more burners directly or indirectly, for example by means of a flash tube
3.4.2.3
flame supervision device
device which, under the influence of the flame on the detector element, holds open a supply of gas to the
burner and pilot if it exists, and which shuts off at least this supply of gas in the event of extinction of the
supervised flame
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
a) one which controls all of the gas supply to the burner and pilot, if it exists;
b) one which partially controls the supply of gas to the burner and pilot, if it exists (see 5.2.12.1).
14
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.4.2.4
putting an adjuster or control out of service
adjuster or control (of rate, pressure etc.) is said to be put out of service if it is put out of action and sealed in
this position; the appliance then functions as if this device had been removed
3.4.2.5
means of assuring soundness
any static or dynamic device intended to assure soundness, for example: flat face joints, O-ring joints, conical
joints, diaphragms, greases, pastes, mastics
3.4.2.6
primary air adjuster
device allowing the primary aeration of a burner to be set at a pre-determined value according to the supply
conditions
NOTE The operation of changing the setting of this device is termed the "adjustment of primary air".
3.4.2.7
gas rate adjuster
device allowing the gas rate to a burner to be set at a pre-determined value according to the supply conditions
NOTE 1 The adjustment may be continuous (adjustment screw) or discontinuous (change of calibrated orifices, etc.).
NOTE 2 The operation of changing the setting of this device is termed the "adjustment of the gas rate".
3.4.2.8
locking of an adjuster
www.bzfxw.com
immobilization, by the manufacturer or installer, of an adjuster in its adjustment position by some means
(screw, etc.)
3.4.2.9
sealing of an adjuster
any arrangement relating to the adjuster whereby any change to the adjustment causes breaking of the
sealing device and makes interference with the adjuster apparent; the adjuster is then said to be sealed in the
adjusted position.
3.4.2.10
calibrated orifice
device with one or more orifices which is placed in the gas circuit to create a pressure loss and thus reduces
gas pressure of the burner to a pre-determined value for a supply pressure and for a given rate
3.4.2.11
regulator
device which maintains a sensibly constant downstream pressure when the upstream pressure and the gas
rate vary within a range of given values
3.4.2.12
tap
device to isolate the gas supply to a burner and possibly to adjust its gas rate during use
3.4.2.13
thermostat
device to maintain automatically a temperature within given limits
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
NOTE It generally includes a graduated scale for the selection of the cooking temperature depending on the cooking
being undertaken.
15
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.4.2.14
multifunctional control
control having two or more functions, one of which is a shut-off function, integrated within one housing,
whereby the functional parts cannot be operated if separated
3.4.3.1
control handle
part intended to be manually operated in order to operate an appliance control, such as a tap, cock,
thermostat, etc.
3.4.3.2
touchable parts
external parts of the appliance intended to be handled in normal use
3.4.3.3
combustion circuit
assembly consisting of a combustion chamber and a circuit for the evacuation of the combustion products
3.4.3.4
hotplate
part of a cooking appliance comprising one or several covered or uncovered burners, and/or one or more
electric cooking plates, and possibly a griddle
3.4.3.5
pan support
www.bzfxw.com
support placed above an uncovered hotplate burner, which supports the pan being heated
3.4.3.6
griddle
part of a hotplate consisting of a plate situated above a burner that allows cooking of food by direct contact
with its surface when heated to a high temperature
permanent, i.e. designed so that the burner is only to be used under the above conditions;
temporary, i.e. designed so that it may also be used as a an uncovered or covered burner after removal or
replacement of the removable plate.
3.4.3.7
shut-down lid
lid intended to be shut down over the hotplate
3.4.3.8
oven
closed compartment for cooking roasts, pastries, etc.
3.4.3.9
centre of the oven
geometric centre of the useful volume of the oven
3.4.3.10
useful oven height
height calculated from the bottom to the top of the door aperture, which may be reduced in size owing to
projections (base, grill burner or grill frets (see Figure 1))
NOTE 1 When the door is not rectangular, the average height is taken.
16
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
NOTE 2 A door is also regarded as rectangular if it has four rounded corners one or more of which is rounded. These
dimensions do not take account of local projections: bulbs, screws, oven viewing panel, light, etc.
3.4.3.11
useful oven plan area
useful measured dimensions so as to represent the actual surface area available for cooking (see Figure1);
determined from the product of the distance between the shelf supports (or the width of the door aperture,
whichever is smaller) and the distance between the internal surface of the door and:
or the rear vertical plane of the cooking zone as it passes through the furthermost end of the longest oven
accessory held in place by a rear stop device, the calculation being based on whichever is the lower of
these two values.
NOTE These dimensions do not take into account local projections: probes, screws, oven viewing panel light, etc.
3.4.3.12
useful oven volume
v
product of the useful oven plan and the useful oven height (see Figure 1)
3
NOTE The useful oven volume is expressed in cubic decimetre (dm ).
3.4.3.13
shelf supports
supports in the side walls of the oven or grill intended to support oven or grill accessories
3.4.3.14
www.bzfxw.com
oven and grill accessories
accessories delivered with the appliance, or mentioned as optional, used for oven and grill cooking
EXAMPLES:
the grid which is intended to support food to be cooked in the oven or under the grill and to keep the food from
contact with cooking juices. It also serves as a shelf for supporting dishes in the oven;
the grill pan: pan used to collect juices from grill cooking or to hold food cooked in the oven;
3.4.3.15
viewing panel
area of transparent material allowing the inside of a compartment to be seen
3.4.3.16
grill
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
appliance or part of an appliance that allows cooking by radiant heat from a surface which is raised to a high
temperature
3.5.1
yellow tipping
phenomenon characterized by the appearance of yellow colouring at the top of the blue cone of an aerated
flame
17
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.5.2
sooting
phenomenon appearing at the time of incomplete combustion and characterized by a deposit of soot on the
surfaces in contact with the flames or the products of combustion
3.5.3
mass flow rate
M
mass of gas consumed by the appliance in unit time during continuous operation
NOTE The mass flow rate is expressed in kilogram per hour (kg/h), or eventually gram per hour (g/h).
3.5.4
volume rate
V
volume of gas consumed by the burner or burners in unit time, with the gas under reference conditions
3
NOTE The volume rate is expressed in cubic meter per hour (m /h) or possibly litre per minute (l/min), litre per second
3 3
(l/s), cubic decimetre per hour (dm /h), cubic decimetre per second (dm /s).
3.5.5
heat input
Q
quantity of energy consumed per unit of time corresponding to the volume or mass flow rates, the calorific
value to be considered in this standard being the gross calorific value
3.5.6
www.bzfxw.com
nominal heat input of a burner
Qn
value of the heat input as declared by the manufacturer
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
3.5.7
primary aeration rate
ratio between the volume of primary air and the volume of theoretical air
3.5.8
primary air
volume of air entrained at the injector by unit volume of gas
3.5.9
flame lift
phenomenon characterized by the partial or total movement of the base of the flame away from the burner
port
3.5.10
light back
phenomenon characterized by the return of the flame inside the body of the burner
3.5.11
flame stability
state of the flames at the burner ports when the phenomena of flame lift or light back do not occur
3.5.12
opening time
time which elapses between the ignition of the supervised flame and the moment when the effect of this flame
is sufficient to hold open the shut-off device
18
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.5.13
extinction delay time
time which elapses between the extinction of the supervised flame and the closure of the gas supply
controlled by the flame supervision device
3.5.14
centre oven temperature
temperature measured at the centre of the oven using a bare thermocouple
3.5.15
remote operation (type 1)
operation by means of a control intended to be actuated out of sight of the appliance, such as by
telecommunications or bus systems
3.5.16
remote operation (type 2)
operation by means of a separate hand-held control (e.g. an infrared device) designed for use only when the
appliance is directly visible to an operator of the control who is present within the same room as the appliance
4 Classification
Gases are classified in three families, which may be divided into groups according to the value of the Wobbe
index. Table 2 gives the families and groups of gases used in this European Standard.
Families and groups of gases Gross Wobbe index at 15 °C and 1 013, 25 mbar
3
MJ/m
minimum maximum
1st family
- Group a 22,4 24,8
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
19
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
4.2.1 General
Appliances are classified by categories defined according to the gases and pressures for which they are
designed.
In each country, only some of the categories defined in 4.2.2, 4.2.3 and 4.2.4 are marketed, on account of
local gas distribution conditions (composition of gases and supply pressures).
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The situations relating to the marketing of these categories of appliance in each country, and the
corresponding supply pressures, are given in Tables A.1 and A.2 (see also in A.4 particular categories
marketed locally and nationally corresponding to the specific gases and supply pressures given in Table A.4;
A.5 gives certain conditions relating to a specific country).
4.2.2 Category I
4.2.2.1 General
Appliances in category I are designed exclusively for use with gases of a single family or of a single group.
4.2.2.2 Appliances designed for use with gases of the first family only
Category I1a: Appliances using only gases from group a of the first family, at the fixed supply pressure (this
category is not used).
4.2.2.3 Appliances designed for use with gases of the second family only
Category I2H: Appliances using only gases from group H of the second family, at the fixed supply pressure.
Category I2L: Appliances using only gases from group L of the second family, at the fixed supply pressure.
Category I2E: Appliances using only gases from group E of the second family, at the fixed supply pressure.
Category I2E+: Appliances using only gases from group E of the second family, and operating without
intervention on the appliance with a pressure couple. The device for regulating the gas pressure of the
appliance, if any, is not operational within the range of the two normal pressures of the pressure couple.
4.2.2.4 Appliances designed for use with gases of the third family only
Category I3B/P: Appliances capable of using gases of the third family (propane and butane) at the fixed
supply pressure.
Category I3+: Appliances capable of using gases of the third family (propane and butane) and operating with
a pressure couple without intervention on the appliance other than an adjustment of the primary air for
conversion from butane to propane and vice versa. No operational device for regulating gas pressure is
permitted in the appliance.
Category I3P: Appliances using only gases from group P of the third family (propane) at the fixed supply
pressure.
20
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
4.2.3 Category II
4.2.3.1 General
Appliances of category II are designed for use with gases of two families.
4.2.3.2 Appliances designed for use with gases of the first and second families
Category II1a2H: Appliances capable of using gases from group a of the first family and gases from group H
of the second family. Gases of the first family are used under the same conditions as for category I1a. Gases
of the second family are used under the same conditions as for category I2H.
4.2.3.3 Appliances designed for use with gases of the second and third families
Category II2H3B/P: Appliances capable of using gases from group H of the second family and gases of the
third family. Gases of the second family are used under the same conditions as for category I2H. Gases of the
third family are used under the same conditions as for category I3B/P.
Category II2H3+: Appliances capable of using gases from group H of the second family and gases of the third
family. Gases of the second family are used under the same conditions as for category I2H. Gases of the third
family are used under the same conditions as for category I3+.
Category II2H3P: Appliances capable of using gases from group H of the second family and gases from group
P of the third family. Gases of the second family are used under the same conditions as for category I2H.
Gases of the third family are used under the same conditions as for category I3P.
Category II2L3B/P: Appliances capable of using gases from group L of the second family and gases of the
third family. Gases of the second family are used under the same conditions as for category I2L. Gases of the
third family are used under the same conditions as for category I3B/P.
Category II2L3P: Appliances capable of using gases from group L of the second family and gases from group
P of the third family. Gases of the second family are used under the same conditions as for category I2L.
Gases of the third family are used under the same conditions as for category I3P.
Category II2E3B/P: Appliances capable of using gases from group E of the second family and gases of the
third family. Gases of the second family are used under the same conditions as for category I2E. Gases of the
third family are used under the same conditions as for category I3B/P.
Category II2E+3+: Appliances capable of using gases from group E of the second family and gases of the
third family. Gases of the second family are used under the same conditions as for category I2E+. Gases of
the third family are used under the same conditions as for category I3+.
Appliances of category III are designed for use with gases of the three families.
The categories III permitted in certain countries are given in Annex A (see A.4).
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
21
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
b) Class 2: Appliance for building in between two furniture units. These appliances are divided into two
subclasses.
1) Class 2 - subclass 1: Class 2 appliance made in one complete unit but also capable of being
installed so that the side walls are accessible.
2) Class 2 - subclass 2: Class 2 appliance consisting of one or more ovens or oven/grills, placed
beneath the worktop and, possibly, a hotplate built into the worktop.
5 Constructional requirements
5.1 General
5.1.1.1 General
The only acceptable operations when converting from a gas of one group or family to a gas of another group
or family and/or to adapt to different gas distribution pressures are given below for each category.
It is recommended that these operations should be possible without disconnecting the appliance.
Unless otherwise specified, conformity to the requirements of this clause is checked by inspection.
5.1.1.2 Category I
category I3+: Replacement of injectors or calibrated orifices but only in order to convert from one
pressure couple to another (for example 28-30/37 mbar to 50/67 mbar). Adjustment of primary air when
converting from one pressure couple to another or from one pressure to another within a pressure couple;
category I3P: No modification to appliance relative to a change of gas. For changing pressure:
replacement of injectors, adjustment of gas rates and adjustment of primary air.
5.1.1.3 Category II
5.1.1.3.1 Categories of appliance designed for use with gases of the first and second families
22
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
putting the gas rate adjuster out of service for gases of the second family.
These adjustments are only acceptable when converting from a gas of the first family to a gas of the second
family or vice versa.
5.1.1.3.2 Categories of appliance designed for use with gases of the second and third families
for gases of the third family, putting the reduced gas flow adjusters out of service.
for converting from a butane/propane pressure couple to another couple (e.g. 28-30/37 mbar
to 50/67 mbar).
To convert from one gas to another within a pressure couple of third family gases, it is only permissible to
adjust the primary air.
The adjustments or replacements of parts permitted for converting from one gas of one family to a gas of
another family, or for converting from one butane/propane pressure couple to another, are the following:
for third family gases, putting the reduced gas rate adjuster out of service.
To convert from one gas to another within a pressure couple of a third family gas, it is only permissible to
adjust the primary air.
5.1.2 Materials
5.1.2.1 General
The nature and state of the surface of materials intended to come into contact with food shall be such that
they cannot contaminate or degrade this food.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
23
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The quality and thickness of materials used in the construction of the appliance shall be such that the
constructional and performance characteristics are not altered in use. In particular, all parts of the appliance,
when it is installed according to the instructions and the appropriate rules, shall withstand the mechanical,
chemical and thermal conditions to which they could be submitted during normal use, for example:
the pilot gas supply circuit shall not be made of copper unless the metal is protected against the action of
the gas;
condensation produced during starting and/or operation of the appliance shall not reduce its safety.
Parts not made of corrosion resistant material shall have effective protection against corrosion. This
requirement does not apply to the cake tray.
Materials containing asbestos shall not be used in the construction of the appliance.
If elastomeric materials are used for seals in gas carrying parts of the appliance other than in gas controls,
they shall comply with the relevant requirements of EN 549:1994.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Sealing materials for metallic threaded joints in gas carrying parts shall be in accordance with EN 751-1:1996
(for anaerobic jointing compounds) or EN 751-2:1996 (for non-hardening jointing compounds).
5.1.2.2.1 General
Glass components or glass ceramic parts including their edges or corners shall not have fissures or scratches.
The means used to hold glass components or glass ceramic parts of the appliance shall not allow any
unnecessary stress or risk of mechanical damage to the glass or glass ceramic. For example, screws used for
assembly shall not come into contact with glass components or glass ceramic parts.
The materials used for glass ceramic components shall have the mechanical characteristics that ensure
durability against damage in normal use.
This requirement is deemed to be met if, after application of the test given in 7.2.1.4.1 the glass ceramic
surface is not broken and does not show any crack visible to the naked eye.
When a pan support for an uncovered burner is in contact with the glass ceramic surface of the hotplate, the
surface area of the pan support in contact with the glass ceramic surface shall be at least 25 mm².
Glass components of thermally toughened soda-lime glass (for example the shut-down lid, oven viewing panel,
control panels) shall fragment into small particles.
General compliance with this requirement for thermally toughened soda-lime glass is verified by testing
according to 8.10 of ISO 15717:1998, except that the number of glass fragments contained in a square of side
50 mm located in the area of the largest pieces shall be at least 60.
24
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
It can be verified by presentation of a declaration of conformity by the glass manufacturer that the thermally
toughened soda-lime glass used in the construction of the component is manufactured to comply with the
requirement above.
If any other types of glass are used, the manufacturer shall provide evidence that:
a) similar safety tests, suitable to the particular material, have been successfully applied;
If such glass is major component (e.g. oven doors, facial or side panels) the glass surface shall not be broken
and shall not show any crack visible to the naked eye after application of the tests given in 7.2.1.4.
Any part of the appliance requiring cleaning by the user shall be easily accessible without having to move the
appliance or use a tool for dismantling. It shall be possible to replace such parts correctly and without undue
difficulty in accordance with the information in the instructions for use and maintenance. Any incorrect
reassembly (e.g. pan support arms-pots centring clearly out centred with respect to the burner lay out, or pan
supports opening diameter clearly larger than the diameter of the burner) shall be obvious, if this could create
a potential hazard to the user.
Sharp borders and edges which could give rise to injury to the user, for example during cleaning, shall be
avoided.
Any control placed in the gas circuit shall be arranged so that any adjustment or maintenance by a service
engineer is easy and its replacement by a service engineer is possible.
Parts of the appliance which are not intended to be removed by the user, and for which removal would affect
safety (for example injectors) shall only be able to be removed with the aid of tools.
5.1.4 Strength
5.1.4.1 General
The construction of an appliance shall be such that, during normal conditions of use, it shall not be possible to
detect:
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
any distortion;
any deterioration;
The conformity of the appliance to the strength requirement is checked by the absence of visible change in the
functional parts following the two tests described in 5.1.4.2 and 5.1.4.3, and by the conformity of the whole
appliance to the specifications of the standard.
These two tests, when applied, are carried out under the conditions described in 7.2.1 before undertaking the
tests or checks specified by the standard, apart from the soundness test specified in 7.3.1.1 which is carried
out on the appliance in its as-delivered condition.
25
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
For cookers of class 1 and class 2, subclass 1, the application of a force to the upper part under the conditions
of 7.2.1.2.
For all appliances, the application on the pan supports of the loads indicated in 7.2.1.3 under the specified
conditions.
Holes for screws, fixing pins etc. intended for the assembly of components shall not open into the gas ways
which lead to the injector.
The soundness of parts and assemblies connected to the gas circuit shall be assured, by means of metal-to-
metal joints or joints with seals (e.g. washer, O-rings or gaskets), i.e. excluding the use of any product which
ensures soundness in the threads.
However, for parts that do not require to be dismantled during normal maintenance or for a change of gas, the
use of thread sealing compounds is permitted.
Soft soldering, as defined in 3.1.6, shall not be used to ensure soundness of the connections of the gas circuit.
However, it is permitted for internal connections within the gas circuit when a damage of the connection does
not involve soundness of the circuit. Conformity will be checked on the basis of the manufacturer's
specifications.
Mechanically fastened components, or the threaded parts of the pipework, which may be dismantled during
normal maintenance shall remain sound after 5 disconnections and reassemblies carried out in accordance
with the manufacturer's instructions, if necessary after changing a gasket, where this is indicated in the
technical instructions.
5.1.6 Connections
For appliances of categories I3B/P, I3+ and I3P, the gas inlet to the appliance may be one of the following
three types (see A.6).
a) Without a thread: for a length of at least 30 mm its extremity shall be cylindrical, smooth and clean to
allow connection by means of a gas-tight compression fitting.
b) With an external thread: its extremity shall have a thread for connection with or without sealing in the
thread according to EN 10226-1:2004, EN 10226-2:2005 or EN ISO 228-1:2003.
In this case, the nominal diameter shall conform to the nominal sizes 1/2, 3/8 or 1/4 taking into account the
requirements of 5.1.6.3.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
c) With an internal thread: its extremity shall have a thread for connection with sealing in the thread
according to EN 10226-1:2004 or EN 10226-2:2005.
In this case, the nominal diameter shall conform to the nominal sizes 1/2, 3/8 or 1/4 taking account of the
requirements of 5.1.6.3.
b) and c) may be achieved, if necessary, by the use of an adaptor fitted on the appliance or supplied with it as
an accessory by the manufacturer. If such an adaptor is supplied with the appliance as an accessory by the
manufacturer, it shall, unless its correct fitting is obvious, have a clear marking indicating the type of thread.
26
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The details for the fitting and use of such an adaptor shall appear in the technical instructions (see 8.3.2). The
installation practices in force in the various countries are given in Table A.6.
For all categories of appliances except categories I3B/P, I3+ and I3P, the extremity of the gas inlet to the
appliance shall have a thread conforming to EN 10226-1:2004, EN 10226-2:2005 or EN ISO 228-1:2003 (see
Table A.6).
For all types of thread, the useful length of thread shall conform to the values indicated in EN 10226-1:2004 or
EN 10226-2:2005.
If the thread is external, the nominal diameter shall conform to the nominal sizes 1/2, 3/8 or 1/4 taking account
of the requirements of 5.1.6.3.
If the thread is internal, it shall comply with EN 10226-1:2004 or EN 10226-2:2005 and the nominal diameter
shall comply with the nominal sizes 1/2, 3/8 or 1/4 taking account of the requirements of 5.1.6.3.
This may be achieved, if necessary, by the use of an adaptor fitted on the appliance or supplied with it as an
accessory by the manufacturer. If such an adaptor is supplied with the appliance as an accessory by the
manufacturer, it shall, unless its correct fitting is obvious, have a clear marking indicating the type of thread.
The details for the fitting and use of such an adaptor shall appear in the technical instructions (see 8.3.2). The
installation practices in force in the various countries are given in Table A.6.
All appliances:
The end of the gas inlet connection shall be positioned to allow the free movement of a flexible hose
connection;
In the case of connections where pressure-tight joints are not made on the threads according to
EN ISO 228-1:2003, the extremity of the gas inlet connection shall have a flat annular surface of at least
3 mm wide in the case of a thread of nominal size 1/2, of at least 2,5 mm wide in the case of a thread of
nominal size 3/8 and of at least 2,2 mm wide in the case of a thread of nominal size 1/4 in order to allow
the interposition of a sealing washer.
Moreover, when the extremity of the gas inlet connection has a thread of nominal size 1/2, it shall be possible
to insert a gauge of 12,3 mm diameter to a depth of at least 4 mm.
Appliances of class 1:
The connection of the gas inlet to the gas supply shall be possible from both the left and the right of the
appliance.
The appliance may have one or two points of connection. If there is only one gas inlet connection point, it
shall be such that connection to the gas supply can be made from either side during normal installation of
the appliance. In order to satisfy this requirement, the use of supplementary means provided by the
manufacturer is allowed. If, for this purpose, a part of the pipework is movable, it shall be sufficiently rigid,
if necessary by use of a means of support.
The end of the gas inlet connection may be fitted with a push-on connection (see Table A.6). This
connector may be installed on the appliance.
They shall be designed so that the connection to the gas supply may easily be carried out in accordance
with the instructions of the manufacturer.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
27
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The appliance shall not be dismantled for connection unless the manufacturer recommends the use of a
flexible hose.
The end of the gas inlet connection may be fitted with a push-on connector when the appliances are
supplied with liquefied petroleum gas, as indicated in Table A.6.
If the appliance has devices such as castors allowing it to be moved, a means shall be provided to stop
inadvertent movement of the appliance in normal use.
With the mobility device in use (unless this is evident to the user), the appliance shall not tilt under the test
conditions described in 7.2.2.3.
The appliance shall be so designed that it can be provided with a fixing or stabilisation device when the
installation rules in force in the country where it is to be installed require fixing or stabilisation of appliances.
Appliances of class 2, subclass 2, and class 3 shall be capable of being positioned correctly and secured after
installation.
For appliances of class 2 and class 3, any additional components necessary for the evacuation of products of
combustion and for ventilation specified by the manufacturer shall be supplied with the appliance, with the
exception of those that are commercially available and for which the characteristics and installation are
specified in the technical instructions.
5.1.10 Safety of operation in the event of fluctuation, interruption and restoration of the auxiliary
energy
When the appliance is supplied by a mains electrical supply, its design shall be such that no risk can appear in
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
the event of loss of the electrical energy and its subsequent restoration.
NOTE Requirements relating to the continued operation and safety of the appliance in the event of normal and
abnormal fluctuation of electrical energy are specified in 6.2.2 and 6.3.2.
Appliances with electrical components other than electrical heating elements associated with the use of gas
shall comply with the relevant clauses of EN 60335-2-102:2006 and with those clauses of EN 60335-2-6:2003
given in the following list:
28
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
NOTE The electrical safety of cooking functions performed by electrically heated components is not covered by this
European Standard; appropriate requirements are given in EN 60335-2-6:2003.
If the appliance incorporates automatic controls these components shall comply with the relevant clauses of
EN 60730-2-1:1997.
5.2.1 Taps
Each burner shall be controlled by a tap or a device assuring the opening and closing of its supply and where
required allowing the variation of its rate between two extreme values by operation of the control handle.
Where a manually operated tap is covered by the scope of EN 1106:2001, the requirements of EN 1106:2001
shall be applied and the number of operations of the taps shall be:
Taps shall be placed in such a way that their strength, operation, manipulation and accessibility undergo no
damage from actions to which they are subjected in normal use, and that they are protected against spillage
of food.
All parts of the taps shall be clean (e.g. free from swarf).
Taps shall be mounted in such a way that no accidental movement relative to the gas supply connection is
possible. Taps shall be replaceable.
For a given appliance, all the taps controlling the same type of burners shall be of the same type, e.g. with the
reduced rate either at the end of the tap travel or between the closed and full on positions.
If the oven and grill burners have a combined control tap, the "off" position shall be designed to make it
impossible for the tap handle to be inadvertently moved from one adjustment range to another, for example
requiring an axial displacement. If the burners are fitted with flame supervision devices, a combined tap
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
29
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
requires only a device to arrest it in its "off" position, for example an arrest !, in compliance with 7.7.1.3 of
EN 1106:2001."
!If a multi-ring hotplate burner has a single sectional control with two closing directions, the "off" position
shall be designed to make it impossible for the tap handle to be inadvertently moved from one adjustment
range to another, for example requiring an axial displacement. However, if each ring of such a multi-sectional
hotplate burner is supervised by a flame supervision device, the single sectional control requires only a device
to arrest it in its "off" position, for example an arrest, in compliance with 7.7.1.3 of EN 1106:2001."
If the oven and grill burners are situated in the same compartment and they are controlled by different control
taps, an interlock device shall prevent gas being supplied to the two burners simultaneously.
5.2.2.1 Design
The purpose of handles shall be clearly identifiable with respect to the burners they control. There shall not be
any risk of confusion with the control for other energy.
If the control handle operates by turning, the closing direction !shall only be clockwise". This does not
apply to combined oven and grill tap handles !and to multi-ring hotplate burners with a single sectional
control and two closing directions."
Control handles shall be so arranged relative to one another, and with respect to control handles for any other
energy, that the movement of one handle does not cause inadvertent movement of an adjacent handle.
Control handles shall be so designed that they can neither be fitted in the wrong position nor move by
themselves.
Control handles shall not be interchangeable if this leads to a risk of confusion between the energy controlled,
the closing direction, the operating positions and the "off" position.
5.2.2.2 Marking
For each burner the closed, open and, if it exists, the reduced rate positions shall be marked in a visible,
legible, identifiable and durable fashion.
The marking, symbols and index shall be identifiable to the user during operation of the appliance when the
tap is in the appropriate position.
The position of handles is determined by alignment of symbols with an index: the index may be fixed and the
symbols carried on the handle (or on a device controlled by it) or vice versa. However, alternative means of
determining the position of handles may be used if they are equally effective, e.g. the appearance of symbols
in a window on condition that:
in any position, a symbol or a significant part of the symbol, is visible in the window; the visible part of the
symbol shall enable the reduced rate direction to be identified;
the closing direction is clearly apparent, whatever the position of the handle, if this is different from the
reduced rate direction.
If control handles do not operate by rotation, the same symbols shall be used in a manner which prevents any
ambiguity.
For needle type taps, the closing direction shall be indicated by an arrow whose point is directed towards the
full disc or circle indicating the closed position. Marking of the reduced rate position is not required.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
30
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
If the axes of the handles are horizontal (or nearly horizontal), the closed position shall be situated in the
vertical plane containing the axes of the handles, and above them.
If the axes of the handles are vertical (or nearly vertical), and in a plane parallel or perpendicular to the front of
the appliance, the closed positions may be selected from the four positions defined by the two vertical planes
containing the axis of the handle which are parallel and perpendicular to the front of the appliance.
The closed position shall be the same for all the taps.
In all cases, including needle type taps, the identification of the closed position of the tap shall not give rise to
any confusion with the identification of the open position, or with other markings.
The closed position shall be marked with a full disc or a circle of at least 3 mm in diameter:
or .
or
- scale 1 2 3 4 or 4321
Other symbols, with the exception of letters, may be used, on condition that they give equivalent information
clearly.
Additional markings are allowed on condition that they create no confusion for the user of the appliance.
Any special position of the tap which is intended for ignition and/or any special button which has to be
operated for ignition shall be marked with a stylised star.
if there are two control handles, the full-on and closed positions of the tap shall be marked as indicated
above; any reduced rate position shall also be marked;
if there is only a single control handle, the closed position of the tap shall be marked as indicated above.
If there is a risk of confusion between the control handle of the oven burner and that of the grill burner, the
control handle of the oven burner shall be marked by a rectangle carrying a clearly identifiable symbol in its
lower part and that of the grill burner by a rectangle carrying a clearly identifiable symbol in its upper part.
When the burner of the oven and grill are controlled by the same handle, these markings are used for each of
the corresponding ranges.
31
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Injectors
It shall be possible to dismantle injectors. However, for appliances intended to operate exclusively with an
injector mounted in the factory (appliances of categories I2H, I2L, I2E, I2E+, I3B/P, I3+, I3P), the interposition
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
of a sealing material in the thread is permissible if the installation instructions mention that it is mandatory to
use this product in the case of disassembly.
Every injector shall have an indelible means of allowing it to be identified with the aid of the instructions, so
preventing any confusion.
When a gas rate adjuster is an adjustable injector for use with butane and propane, the gas rates, main and
reduced, shall be controlled by means of a calibrated orifice, annulling the adjustment possibility intended for
other gases.
they shall have been adjusted in the factory, in compliance with the gas family, gas group and pressure
for which the appliance is labelled;
if this position is to be altered when the gas is changed, instructions for conversion to various gases,
provided in 8.3.4, shall describe the operations to be carried out and shall clearly specify the adjustment
position to be attained;
the main gas rate adjusters shall either be locked in a predetermined adjustment position2) and sealed, or
immobilised in this position and sealed by a means such as a sealed stop;
Instructions for conversion to various gases shall also specify that any sealing shall be restored after the gas
conversion operations.
It shall only be possible to move the adjusters with the use of a tool.
With the exception of independent hotplates, table cookers and movable cookers, the gas rate adjusters of all
the burners shall be accessible to the installer without having to move the appliance when it is installed under
the conditions specified in 7.1.3.3.
Adjusting screws shall be placed so that they cannot fall into the gas ways. They shall be fitted with a cap or
some other sealing device.
they shall have been adjusted in the factory, in compliance with the gas family, gas group and pressure
for which the appliance is labelled;
2 ) The meaning of "predetermined adjustment position" is the position of the adjuster which may be obtained
unambiguously and independently of the gas composition used (for example, stop device, dimensions, mark, pressure,
number of screw turns).
32
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
if this position is to be altered when the gas is changed, instructions for conversion to various gases
provided in 8.3.4 shall describe the operations to be carried out and shall clearly specify the adjustment
position to be attained;
the air rate adjusters for the main burners shall be locked in a predetermined adjustment position3) and
sealed;
the air rate adjusters for the ignition burners shall be locked in the adjustment position.
Instructions for conversion to various gases shall also specify that any sealing shall be restored after the gas
conversion operations.
It shall only be possible to move the adjusters with the use of a tool.
With the exception of independent hotplates, table cookers and movable cookers, the air rate adjusters of all
the burners shall be accessible to the installer without having to move the appliance when it is installed under
the conditions specified in 7.1.3.3.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Presence of adjusters
A continuous-action adjuster, adjusted, locked and sealed by the manufacturer or his agent and which
according to the technical instructions, shall not be adjusted at the moment of installation is considered to be
non-existent.
The presence of gas rate adjusters is optional for appliances of category II1a2H. For these appliances, where
they are supplied with a second family gas, annulment of the function of the continuous nominal flow rate
adjusters is obligatory, annulment of the function of continuous reduced flow rate adjusters is optional.
Appliances of categories I2H, I2L, I2E, I2E+, I3B/P, I3+, I3P, II2H3B/P, II2H3+, II2H3P, II2E3B/P, II2E+3+
shall not be fitted with continuous gas rate adjusters. However, it is permissible to adjust reduced rates for
appliances of categories II2H3B/P, II2H3+, II2H3P and II2E3B/P, II2E3+, II2E+3+ when using second family
gases; the same applies to category I2E+ when it is marketed in one country jointly with category II2E+3+.
The presence of primary air adjusters is optional for all categories apart from categories I2H, I2L, I2E, I2E+
and I3P for which they are prohibited.
Special requirements regarding the presence of adjusters for appliances of category III are given in Annex A
(see A.4).
if there is only a single control handle, the closed position as well as the maximum and minimum positions
shall be marked; the symbol for the closed position shall be as indicated in 5.2.2.2;
if there are two control handles, the one for the tap shall satisfy the requirements of 5.2.2 and the marking
of the thermostat handle shall include at least an indication of the maximum and minimum positions.
3 ) The meaning of "predetermined adjustment position" is the position of the adjuster which may be obtained
unambiguously and independently of the gas composition used (for example, stop device, dimensions, mark, pressure,
number of screw turns).
33
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
All the components of the ignition device shall be designed to avoid damage or accidental displacement in
normal use. The relative positions of the ignition device and the burner shall be sufficiently well defined to
ensure satisfactory operation of the assembly.
When the ignition devices include a permanent pilot, the gas rate of this pilot shall not exceed 0,06 kW for
each burner controlled.
If necessary, it shall be possible to adjust the pilot gas rate in the event of a gas change, either by adjuster or
by change of injector.
A means shall be provided to cut off the gas supply to any pilot.
In the event of failure of the ignition system for the burner(s) of the appliance, it shall be possible in the
following circumstances to light the burner(s) concerned with a match after removing, if necessary, a movable
part (griddle, bottom of the oven etc.):
c) ovens and grill burners that can only be ignited after manual intervention.
This requirement shall not apply to oven burners that are designed specifically to prevent the ignition by
means of a match.
In this case, the manufacturer’s instructions for use and maintenance shall state that the ignition by means of
a match is prohibited.
The ignition system shall meet the requirements of 6.2.1 and 6.3.1.
Where the flame supervision device is covered by the scope of EN 125:1991, the requirements of
EN 125:1991 shall be applied.
Where flame supervision devices are fitted, in order to comply with the requirements of 5.2.12, they shall be
so designed that, in the case of a failure of any of the components indispensable to their operation, the supply
of gas controlled by the device is cut off automatically and that its re-establishment requires manual
intervention. It shall be so mounted as to ensure satisfactory performance. The sensing element of a flame
supervision device shall control a single burner only.
The appliance shall not incorporate any device that allows the flame supervision device to be permanently
over-ridden. However, during the ignition operation, a momentary admission of gas in the absence of a flame
is permitted under the conditions of 6.1.3, if this requires a continuous manual action.
5.2.7 Regulators
Where the regulator is covered by the scope of EN 88-1:2007, the requirements of EN 88-1:2007 shall be
applied.
Except for appliances of categories having the index 2E+, the presence of a regulator is prohibited, or its
function shall be annulled, when appliances are equipped and adjusted to operate without modification or
adjustment of the gas rate within a pressure couple. Appliances of categories having the index 2E+ may have
an appliance regulator if this is not operational within the range of the two normal pressures of this pressure
couple.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
34
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Where a regulator is used, the appliance shall have a pressure test point downstream of the regulator. The
0
pressure test point shall have an external diameter of 9 −0,5 mm and a useful length of at least 10 mm to
allow connection of a rubber tube. At least one part of the orifice of the pressure test point shall have a
diameter not exceeding 1 mm.
The design and accessibility of the regulator shall be such that it can be easily adjusted and immobilized for
use with another gas, but provision shall be made to hinder any unauthorized access to the adjuster. Where a
regulator is locked in the open position and sealed, it is considered to be non-existent.
5.2.8 Hotplates
There shall be an adequate number of points of support for vessels to rest level in a stable fashion on the
supports of each of the uncovered burners.
Except where rim-based or convex-based vessels are required, one of the pans defined in C.1 is used for
verification purposes. This pan shall have the largest diameter which is equal to, or less than, that of the
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
smallest pan specified in the instructions for use and maintenance. It is verified that when the pan is displaced
off-centre by 15 mm, it remains stable.
The instructions for use shall state the minimum diameter of the pan that can be placed on each of the
burners. At least one of these pans shall have a diameter of 120 mm or less except for single burner
appliances having a nominal heat input greater than 3 kW.
In the case where the instructions for use and maintenance do not prohibit the use of rim based or convex-
based vessels on the hotplate, the following verification is carried out.
The following rings are placed on the pan support over each burner:
external diameter: 140 mm, 160 mm, 180 mm and 200 mm;
height: 25 mm;
thickness: 3 mm;
then moved off-centre by up to 25 % of their diameter. In all these positions, they shall be supported
sufficiently at a level equivalent to that of a flat based vessel of the same diameter.
If the pan supports are designed to be removed, in two or more separate parts, for example for cleaning, the
removal of one or more of these parts shall not make the remaining parts unstable.
In normal use, the hotplate pan supports shall not suffer distortion likely to impair the performance of the
appliance.
Possible spillages from pans placed on the burners shall not affect the operation of the burners and shall be
accessible for cleaning. If the appliance is constructed in such a way that spillages are collected in spillage
containers, the minimum capacity of each container shall be 0,3 l.
It shall not be possible for shut-down lids, pan supports and spillage containers to fall accidentally from their
fully raised position. This requirement shall be verified under the conditions of 7.2.2.5.
If the appliance is fitted with a glass shut-down lid, it shall meet the requirements in a) or b) below at the
discretion of the manufacturer:
35
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
a) The glass shut-down lid shall have a warning notice stating: "Caution: glass lids may shatter when
heated. Turn off all the burners before shutting the lid." or the symbol as represented in Annex F.
This warning notice or symbol shall be incorporated (e.g. screen printed) in the glass and shall be
positioned so that it is legible when the lid is on open position. The warning notice or the meaning of the
symbol shall also be stated in the instructions for use and maintenance (see 8.3.3).
b) The appliance shall have a gas shut-off device which interrupts the gas supplied to the hotplate burners
when the lid is closed. This device shall be designed and installed so that the following requirements are
met under the test conditions described in 7.2.4:
1. no reduction in the gas rate of the burners shall be observed if the lid is moved through an angle of
5° relative to the fully-open position; this requirement is not applicable if the lid is held in the fully-
open position by a mechanical device and
2. the gas supply shall be interrupted if the lid is moved 45° from its fully-opened position.
Glass shut-down lids shall be fitted with a device slowing down their rate of descent.
For appliances having a glass shut-down lid, means shall be provided to prevent a 200 mm test pan
conforming to Table C.1 resting flat on the pan supports from coming into contact with the glass part shut-
down lid when in its fully raised position.
5.2.8.2.1 General
Burner bodies shall be mounted such that they cannot be displaced accidentally from their correct positions.
Parts of a burner likely to be soiled as a result of cooking shall be removable and easy to clean.
However, if these parts have an external shape that makes cleaning easy without affecting the subsequent
performance of the burner, they may be fixed. Burner ports shall be designed so that spillage of food does not
cause internal fouling.
All removable burner parts, particularly the caps, shall not be interchangeable if they are not identical. Any
incorrect reassembly shall be obvious.
The flash tubes and parts with which they are intended to function, particularly those parts of the burner
concerned with the ignition, shall be placed in well defined positions.
When a covered burner or griddle is temporary, the plate shall be removable and shall be supplied with the
appliance.
Correct replacement of the removable plate or griddle on the burner for which it is intended shall be easy and
obvious. The removable plate or griddle shall be stable when in its correct position.
Non enclosed covered burners and griddles shall be designed so that all products of combustion are
evacuated directly to the atmosphere, e.g. around their periphery. In addition, partial visibility of the flames
shall be possible in normal operation.
Griddles shall be designed such that any grease produced in cooking cannot spill onto the burner or onto
parts not intended for this purpose.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
36
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
When a multi-ring hotplate burner with sectional control has separate gas taps to supply and control each of
its rings of burner ports independently, it shall be so designed and arranged that each ring of burner ports is
supervised by a separate flame supervision device.
If a multi-ring hotplate burner with sectional control is supplied from a single gas tap and it is equipped with a
single flame supervision device that only supervises the flame(s) of one of its rings of burner ports, the gas tap
shall be so designed and arranged that when using it to open the gas supply to an unsupervised ring of burner
ports from the supervised ring of burner ports, it is not possible for the gas tap to be left in a position in which
cross-ignition from one to the other is not assured.
Specially removable supports allowing the use of very small pans are allowed on all of the burners.
They shall be stable and rest in a predetermined position on the pan supports above the burner(s)
intended by the manufacturer and specified in his instructions.
A 60 mm diameter pan, even when moved off-centre by 15 mm, shall rest in a stable fashion on the special
support.
The vessels recommended in the instructions for use and maintenance shall be supplied by the manufacturer
to the laboratory. They shall rest in a stable fashion on the special supports.
If the devices are removable, they shall be supplied with the appliance:
either they shall rest in a stable fashion and in a predetermined position on the pan supports, above the
burner(s) intended by the manufacturer and indicated in the instructions for use and maintenance, and in
this case they are not tested;
or they shall replace the original support in which case they shall be subjected to the tests required by this
European Standard under the conditions specified in the instructions for use and maintenance.
5.2.9.1 Compartments
Under the conditions of 7.2.2.2, the inside surface of oven doors with horizontal hinges and ovens equipped
with a grill, when completely open, shall be horizontal (within ± 5°) and remain in this position.
Moreover, under the conditions of 7.2.2.2, a load as indicated in Table 3 being placed on oven doors with
horizontal or vertical hinges, the front (upper) edge of the door shall not sag by more than 15 mm.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
37
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Appliance Mass
a single oven 10
double ovens
- the larger 10
- the smaller a
(3 + 0,1v)
a 3
v: useful volume of the oven, in dm cube.
Under the conditions of 7.2.2.3, oven doors with horizontal hinges are loaded with 22,5 kg and oven doors
with vertical hinges with 15 kg.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
If, for appliances of class 1 on the floor and class 2, subclass 1, the appliance is provided with a fixing
or !stabilizing device", the requirement shall be satisfied using this device. This requirement does not
apply either to the doors of separate grills situated above the oven or hotplate, nor to wall-mounted grills.
However, in the case of table cookers and freestanding ovens of class 1 and class 2, subclass 1, designed to
be placed on a work surface, compliance with the requirement will be verified with the appliance fixed
according to the manufacturer's instructions.
For appliances of class 2, subclass 2, and class 3, the fixing or stabilizing is carried out in accordance with the
manufacturer's instructions.
When the appliance has an LPG cylinder compartment and in accordance with the instructions for use and
maintenance it can only function with the cylinder in place, the requirement is checked with an empty cylinder
in the compartment. Alternatively, the requirement is checked with the compartment empty.
After the test, the appliance shall continue to satisfy the requirements of this European Standard.
a) When they are loaded as indicated in Table 4 and under the conditions of 7.2.2.4:
the supports or runners of ovens, ovens equipped with grills and separate grills shall be designed so
that the oven accessories intended to slide on these supports or runners still have adequate
guidance and do not incline more than 10° when they are pulled out halfway;
the oven and grill accessories intended to slide on these supports or runners shall slide correctly
when cold and hot;
b) if necessary, the extreme rear position which the oven and grill accessories and the cooking utensils can
occupy shall be made evident, for example with lips or stops, in order not to impair the combustion or
cause overheating;
c) when the grill pan has a handle it shall be so designed that when it is held to carry the grill pan or to pour
fluid contents, it shall not bend or become loose under the conditions of 7.2.2.4.
38
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Accessories Mass
- Ovens,
Ovens incorporating grills:
Grill grid a
(2 + 0,12v)
Grill pan a
(2 + 0,12v)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Cake tray bc
3
- Grills:
Grill grid 3
Grill pan 3
a 3
v : useful volume of the oven, in dm .
b
The instructions shall specify that the load placed on the cake tray shall not be more than 3 kg.
c
If the cake tray is required to be supported by an oven shelf, these requirements do not apply to it.
For appliances capable of using third family gases, the space situated under the oven or grill burners shall be
designed so that in the case of release of un-burnt gas, this gas can escape out of the appliance without risk
of accumulation.
If in normal use an oven is capable of achieving a temperature at the centre of the oven in excess of 350 °C,
the appliance shall incorporate a means which prevents access to the interior of the oven as long as the oven
exceeds 350 °C.
for an appliance with an oven without a special thermostat adjustment position for cleaning, those of
7.3.1.5.2.3 test no. 5;
for an appliance with an oven with a special thermostat adjustment position for cleaning, whichever of the
following is more severe:
If there is no ignition device, it shall be possible to light the oven and grill burners by hand, each at a single
point, in an easy and safe manner, with the compartment door open. If the compartment has two burners with
two taps, there may be two lighting points.
Flash tubes and the parts associated with them, particularly the parts of the burner concerned with ignition,
shall be placed in well defined positions.
39
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The user shall be able to see the burner flames totally or partially either with the door open or shut, depending
on the design of the appliance.
Burner components including the radiating elements of the grill burners shall be mounted in such a way that
they cannot be displaced accidentally from their correct position.
The final outlet for the oven and/or grill products of combustion shall be designed so that accidental
obstruction by pans placed on the hotplate is either not possible or does not give rise to a CO content in the
products of combustion of more than 0,10 % by volume, 15 min after ignition under the test conditions of
7.3.3.2.5.
The opening of this compartment shall be of a size which will permit the easy introduction and removal of the
cylinder.
The dimensions of the opening and of the inside of the compartment shall be at least large enough to
accommodate the largest cylinder (with regulator fitted) specified by the manufacturer in accordance with
8.3.3.
effective ventilation is provided by openings at its base and upper part; the total area of the openings in
the upper part being at least 1/100 of the floor area of the compartment and that of the openings at the
base being at least 1/50 of the floor area of the compartment;
the cylinder support has sufficient mechanical strength to resist permanent deformation under the load of
a full cylinder; an arrangement with the cylinder resting directly on the ground is not allowed;
the cylinder fitted with its regulator can easily be inserted in, or removed from, the compartment;
the cylinder tap is readily accessible and remains easy to manipulate when the cylinder is in place;
overflow of liquid from pans on the hotplate does not fall onto the cylinder or its accessories;
where the appliance may be connected by a flexible tube, the latter shall not be in contact with sharp
edges. The length of flexible tube necessary for correct connection of the cylinder shall be indicated in the
manufacturer's instructions. It shall not be less than 400 mm. The cylinder connection point shall be easily
accessible.
In addition, no internal communication shall exist between the cylinder compartment and the different parts of
the appliance where burners are located.
The ventilation openings of the compartment shall not be able to be obstructed when the appliance is placed
in position.
When an appliance incorporates a cooling fan, this fan shall operate automatically.
The moving parts of the fan shall be positioned or protected such that in normal use appropriate protection is
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
provided for persons against accidents, in accordance with the requirements of EN 60335-2-6:2003.
40
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The appliance shall be provided with means that prevents a dangerous accumulation of un-burnt gas in the
space where the appliance is installed as a result of inadvertent release of un-ignited gas from one or more of
its burners.
Where compliance with this requirement is met by provision of flame supervision devices, these devices shall
comply with the requirements of 5.2.6 and 5.2.12.2.2.
Where an alternative(s) to flame supervision devices is used, compliance with the requirement is deemed to
be met where it is assessed that the alternative provides an equivalent level of safety to that provided by flame
supervision devices that comply with the requirements of 5.2.6 and 5.2.12.2.2.
5.2.12.2.1 General
Any appliance shall be so constructed that gas release during ignition and re-ignition and after flame extinction
is sufficiently limited in order to avoid a dangerous accumulation of un-burnt gas within the appliance.
This requirement is deemed to be satisfied if the requirements of 5.2.12.2.2 to 5.2.12.2.4 are met.
5.2.12.2.2.1 Either a device which controls all of the gas supply to the burner and the
pilot, if it exists, but which requires continuous manual intervention for a short period
(see 6.1.3) in order to open the gas supply during ignition.
5.2.12.2.2.2 Or a device which partially controls the gas supply to the burner and
the pilot, if it exists, but does not require continuous manual intervention for the
purpose of ignition. The heat input that is not controlled by this device shall not
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
exceed 0,6 kW.
5.2.12.2.3.1 Where the burner is fitted with a flame supervision device of the type
described in 5.2.12.2.2.1, the manufacturer's instructions for ignition of that burner
shall include a statement indicating that "the device shall not be operated for more
than 15 s. If after 15 s the burner has not lit, stop operating the device and open the
compartment door and/or wait at least 1 min before attempting a further ignition of the
burner".
if the burner, situated in an oven or grill, can only be ignited with the compartment door open;
if the ignition heat input is, by design and construction, lower than or equal to 0,06 kW.
41
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
5.2.12.2.3.2 Where the burner is fitted with a flame supervision device of the type
described in 5.2.12.2.2.2, it shall be verified under the conditions given in 7.2.3, that
ignition of any accumulation of un-burnt gas, if this is possible, does not affect safety.
Where the burner is not fitted with an automatic re-ignition device, the instructions for use and maintenance
shall include the following in the ignition instructions for the burner:
In the event of the burner flames being accidentally extinguished, turn off the burner control and do not
attempt to re-ignite the burner for at least 1 min.
For time controlled ovens with delayed ignition for which the pilot stays alight during the waiting period, the
temperature rise at equilibrium shall not exceed the ambient temperature by more than 4 K under the
conditions of 7.2.5.
5.3 Additional requirements for appliances having one or more burners that are capable of
remote operation
5.3.1 Application
The appliance shall not incorporate an oven that is capable of remote control unless the oven burner is
thermostatically controlled and the oven is a time-controlled oven designed for delayed start.
If an oven is capable of remote operation, the appliance shall comply the requirements given in 5.3.2 and,
depending on whether the remote operation is type 1 or type 2 (see 3.5.15 and 3.5.16), the requirements
given in 5.3.3 or 5.3.4.
5.3.2 General
The appliance shall be so designed and arranged that remote operation of the burner or burners may only be
achieved after the user has set the appliance for remote operation. When the burner or burners are set for
remote operation this condition shall be indicated visually.
Each burner that is capable of remote operation shall be provided with a direct acting manually operated
control that enables the burner to be used safely in accordance with the manufacturer's instructions when
remote operation is not in use. The appliance shall be so designed and arranged that it is always possible for
the user to utilise these manual operated controls to override remote operation of the burner or burners.
Direct-acting manually operated controls shall comply with 5.2.1 and 5.2.2.
When the appliance, and any hand-held control supplied for type 2 remote operation, are tested in accordance
with all the tests described in 19.11.4 of EN 60335-2-102:2006, it shall be verified that:
the burner or burners are not put into operation when in the stand-by mode and that any gas valves
supplying these burners remain closed;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
the burner or burners are not put into operation when the burner control system is in non-volatile lock-out
and that any gas valves supplying these burners remain closed;
the burner or burners, when in remote operation, continue to operate safely or the burner(s) are shut off
by the burner control system.
42
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The appliance signal receiver/control system shall be provided with a unique recognition code or address and,
possibly, a password that has to be signalled to the appliance by the user in order to initiate remote operation.
Where a password is utilised this may be changed by the user but only after the existing password has been
entered and recognised by the appliance control system.
The appliance signal receiver/control system shall be so designed that the duration of any remote operation
cycle is required to be set before the burner or burners can be operated, unless the burner or burners shut off
automatically at the end of a cycle or continuous operation of the burner or burners is not hazardous.
The appliance signal receiver/control system shall be designed so as to enable the user, when signalling the
appliance remotely:
The appliance shall be supplied with the separate hand-operated control for remote operation of the burner or
burners.
The separate hand-operated control shall be designed and/or programmed by the manufacturer so as to
minimise the risk of its signals operating another appliance.
The appliance signal receiver shall be designed and/or programmed by the manufacturer so as to minimise
the risk of the appliance being operated by the hand-held controls for other appliances.
The separate hand-held control shall be so designed that operation of the appliance by means of this control
is only possible when the appliance is directly visible to an operator of the control who is present in the same
room as the appliance.
at least two distinct manual actions are required to start the operation of any burner (e.g. activation of two
different buttons) and
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
the burner or burners can be shut off quickly by means of a single action if necessary.
6 Performance requirements
6.1 General
6.1.1 Soundness
3
Under the test conditions in 7.3.1.1, any leak detected during each of the tests shall not exceed 0,10 dm /h.
Under the test conditions in 7.3.1.2.1, each of the burners, supplied separately, shall be capable of giving the
nominal heat input stated by the manufacturer.
43
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
for burners equipped with gas rate adjusters, but only to check the manufacturer's adjustment instructions
in accordance with 7.3.1.2.1.2 test n° 3;
the variation between the heat input obtained with each of the gases indicated in 7.3.1.2.1.2 and the nominal
heat input Qn is within the limits indicated below:
if the nominal heat input Qn of the burner does not exceed 2,25 kW, the tolerance shall be ± 8 %;
if the nominal heat input Qn of the burner exceeds 2,25 kW and does not exceed 3,6 kW, the tolerance
shall be ± 0,177 kW;
if the nominal heat input Qn of the burner exceeds 3,6 kW, the tolerance shall be ± 5 %;
the tolerance is extended to ± 10 % for burners fitted with injectors with a diameter more than 0,3 mm but
not exceeding 0,5 mm.
the tolerance is extended to ± 20 % for burners fitted with injectors with a diameter not exceeding 0,3 mm.
If an appliance can function with several gas families, the nominal heat input of the burner is not required to be
identical for all the gas families, however:
the variation of the nominal heat input between the two gas families shall not exceed 10 %;
if the variation of the nominal heat input between two gas families is less than 3 %, the data plate shall
only give the lower value of the nominal heat input, but the documents supplied to the laboratory shall
specify the values for each of the gas families;
if the variation in the nominal heat input of the various gas families is between 3 % and 10 %, the data
plate and the instructions shall include the respective values.
For appliances with gas rate adjusters, the heat input shall be at least equal to the nominal heat input when
measured under the conditions stated in 7.3.1.2.1.2, test no. 1 and at most equal to the nominal heat input
when measured under the conditions stated in 7.3.1.2.1.2 test no. 2.
Under the test conditions in 7.3.1.2.2, the reduced heat input, if any, declared by the manufacturer in the
technical instructions for each of the burners shall not be exceeded.
The reduced rates shall either be fixed (by calibrated orifice) or adjustable according to the appliance category
and the gas group used as given in 5.1.1 and 5.2.3.
Under the test conditions described in 7.3.1.3, the opening time shall be equal to or less than 10 s for hotplate
burners and equal to or less than 15 s for oven and grill burners where there is continuous manual
intervention by the user; if there is no continuous manual intervention, the opening time may be increased to
60 s.
The extinction delay time shall be less than 60 s where the burner is situated in a compartment and less than
90 s in the case of an open burner or a covered burner or under a griddle as defined in 5.2.8.2.2.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
44
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
If a burner is protected by a flame supervision device having a pilot, then, under the test conditions in 7.3.1.3.2,
the ignition or re-ignition shall remain satisfactory or the supply of gas controlled by the device shall be shut off
in the event of blockage of the port which supplies the ignition flame or of any other part of the ignition device
leading to shortening or distortion of the flame.
After the tests in 7.3.1.4.1, the burners shall show no deterioration likely to jeopardize performance.
When a burner, having a body made up of several parts, operates under the test conditions in 7.3.1.4.2.1,
there shall be no leakage of any flammable quantity of air/gas mixture at the joints of the assembly.
When a burner operates under the test conditions in 7.3.1.4.2.2, there shall be no hazardous accumulation of
un-burnt gas within the body of the appliance.
Appliance supplied with gases of the 2nd family of groups H and E shall operate safely at a reduced pressure
of 70 % of the normal test pressure, i.e. 14 mbar.
This requirement is complied with if, under the test conditions in 7.3.1.4.3, the flame of the burner concerned
is not extinguished, or if the gas supply under the control of the flame supervision device is shut-off.
6.1.5 Heating
6.1.5.1.1.1 General
Under the test conditions in 7.3.1.5.2.3, test no.1a, the temperature of those parts of the front and sides of the
appliance which can be touched accidentally shall not exceed the ambient temperature by more than:
- enamelled metal 65 K;
- plastic 100 K.
The temperature rise limit of 100 K also applies to plastic materials having a metal finish of thickness less than
0,1 mm.
NOTE When the thickness of the plastic coating does not exceed 0,3 mm, the temperature rise limits of the
supporting material apply.
These requirements shall not apply to those parts of the front or sides:
45
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
which are not accessible to a test probe 75 mm in diameter having a hemispherical end, or
which, on appliances having a hotplate, are less than 25 mm below the level of the hotplate, excluding the
pan supports, or which are above the hotplate, or
which are of small dimension, such as vents for ventilation or for evacuation of products of combustion,
hinges and trims of which the width of the accessible surface is less than 10 mm, or
which are less than 10 mm from outlet vents intended for the evacuation of products of combustion, or
which are within 10 mm of the gap between the oven door and its mating surface.
Under the test conditions in 7.3.1.5.2.3, test no. 1b, the temperature rises of those parts of the front surface of
the protective means (see 8.3.3) and on the front surface of the oven door which can be touched accidentally
shall not exceed:
enamelled metal: 50 K
The temperature rise limit of 80 K also applies to plastic materials having a metal finish of thickness less than
0,1 mm.
NOTE When the thickness of the plastic coating does not exceed 0,3 mm, the temperature rise limits of the
supporting material apply.
These requirements shall not apply to those parts on the front surface of the protective means or on the front
surface of the oven door:
which are not accessible to a test probe 75 mm in diameter having a hemispherical end, or
which are situated more than 850 mm above the floor when an appliance of class 3 is installed according
to the manufacturer’s instructions, or
If, when installed in accordance with the technical instructions, the base of the independent class 3 hotplate is
not protected from contact by a horizontal partition or plate, the surface temperature of the base, or of any
easily accessible part of the base, shall not exceed the ambient temperature by more than 100 K when
measured under the conditions of 7.3.1.5.2.3, test no. 3.
In the case where the appliance may be connected by means of a flexible tube that is not entirely metallic, the
temperatures of the surfaces of the appliance that are likely to come into contact with the tube, when this is
46
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
installed and connected according to the technical instructions, shall not exceed the ambient temperature by
more than 70 K under the following test conditions:
in addition for an appliance with an oven having a special thermostat adjustment position for cleaning,
those of 7.3.1.5.2.3 test no. 4.
If the end of the appliance supply tubing can be fitted with a push-on connector in accordance with the
national situations indicated in Table A.6, this push-on connector shall be located such that its temperature
does not exceed the ambient temperature by more than 30 K under the following conditions:
in addition, for appliances with ovens having a particular thermostat setting for cleaning, that of
7.3.1.5.2.3, test no. 4.
The temperature of auxiliary equipment, the failure of which can affect the safety of operation of the gas part
of the appliance, shall not exceed the maximum temperature specified by the equipment manufacturer when
measured under the following conditions:
for an appliance with an oven without a special thermostat adjustment position for cleaning, those of
7.3.1.5.2.3 test no. 5;
for appliances with an oven having a special thermostat adjustment position for cleaning, whichever of the
following is more severe:
Under the conditions of 7.3.1.5.2.3, tests no. 2 and 3, the temperature rises above the ambient temperature of
parts, other than oven and grill accessories, intended to be manipulated in normal use, measured only in the
contact zones, shall not exceed the following limits:
plastic: 60 K.
In addition, the above temperature limits shall not be exceeded by such contact zones in the following
particular circumstances:
a) under the conditions of 7.3.1.5.2.3, test no. 4, when an appliance, with a special thermostat adjustment
position for cleaning is operated for cleaning purposes in accordance with the instructions for use and
maintenance and simultaneous operation of hotplate cooking elements is not forbidden;
47
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
b) under the conditions of 7.3.1.5.2.3, test no. 64), when, in accordance with the technical instructions, an
appliance of class 1, that can also be installed between two furniture units, or an appliance of class 2,
subclass 1, that can be installed freestanding, has a grill which operates with the door open;
c) under the conditions of 7.3.1.5.2.3, test no. 3 for parts of handles likely to be operated in normal use,
when the appliance is equipped with a grill for which the grill pan has one or more handles. This
requirement shall not apply to detachable grill pan handles if the manufacturer’s instructions for use and
maintenance warn that such handles are not left attached to the grill pan while the appliance is in use.
If the appliance has any openings at the front for the evacuation of products of combustion or cooling air, the
air temperature at a distance of 100 mm in front of the openings as well as in the normal approach zone of the
appliance handles shall not exceed the ambient temperature by more than 130 K under the following
conditions.
7.3.1.5.2.3, test no. 4, when an appliance has an oven with special thermostat adjustment position for
cleaning, which is operated for cleaning purposes in accordance with the instructions for use and
maintenance and simultaneous operation of hotplate cooking elements is not forbidden;
7.3.1.5.2.3, test no. 65), when, in accordance with the instructions, an appliance of class 1, that can also
be installed between two furniture units, or an appliance of class 2 sub-class 1, that can be installed
freestanding, has a grill that operates with the door open.
6.1.5.2 Temperature of the support, walls, adjacent surfaces and building-in cabinets
The temperature of the support on which the appliance is placed, the panels situated near the appliance and,
for class 2 and class 3 appliances, the walls of the building-in cabinet, including that part of the cabinet
situated above the front of an oven, shall not exceed the ambient temperature by more than 65 K under the
following conditions:
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
for all appliances, those of 7.3.1.5.2.3, tests no. 2 and 3;
in addition for appliances with an oven having a special thermostat setting for cleaning, those of
7.3.1.5.2.3 test no. 4.
Under the test conditions in 7.3.1.6, the temperature rise above ambient of the compartment walls shall not
exceed 30 K at any point that is likely to come into contact with:
4) For these requirements, appliances having a grill which operates with the door open are tested with the appliance
freestanding, if this method of installation is permitted by the manufacturer's instructions. This is because installation of the
appliance between furniture units can increase the thermal draught at the back of the appliance and decrease the heat
emitted from the front of the grill compartment. Test no. 6 applies to those appliances which, although capable of being
installed freestanding, are required to be installed between two furniture units in the other tests given in 7.3.1.5.2.2.
5) For these requirements, appliances having a grill which operates with the door open are tested with the appliance
freestanding, if this method of installation is permitted by the manufacturer's instructions. This is because installation of the
appliance between furniture units can increase the thermal draught at the back of the appliance and decrease the heat
emitted from the front of the grill compartment. Test no. 6 applies to those appliances which, although capable of being
installed freestanding, are required to be installed between two furniture units in the other tests given in 7.3.1.5.2.2.
48
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
a) the flexible tube, taking into account the maximum length specified in the technical instructions, or
The compartment shall be such that, under the test conditions in 7.3.1.6, when the cylinder is in the
compartment, there is no overheating that will produce an increase of vapor pressure within the cylinder
greater than that defined in Table 5.
10 0,35
15 0,40
20 0,45
25 0,50
30 0,55
35 0,60
40 0,65
a
This increase corresponds to a temperature rise of 5 K starting from the appropriate ambient temperature.
Under the test conditions in 7.3.1.7, the total input of the appliance, all the taps being in the fully open position,
shall not be more than 10 % less than the sum of the individual inputs of the different burners supplied
separately under the same conditions.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
An appliance fitted with an operating gas regulator is checked to ensure that, under the conditions in 7.3.1.8,
the gas-rate does not vary by more than ± 7,5 % of the rate obtained at the normal test pressure.
Where an appliance has a cooling fan, the requirements regarding the operation of the burner or burners are
verified under the operating conditions for which the fan is designed.
In addition, in all cases in which operation of the burner may require the operation of the fan, the appliance
shall meet the requirements described in 6.1.9.1, 6.1.9.2 or 6.1.9.3 as appropriate.
49
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
6.1.9.1 The following requirements are applicable to appliances fitted with a safety device which, in the
event of a fault in the operation of the fan, automatically interrupts the supply of gas to the burner(s), so that
the maximum temperature rise of the supports, walls and adjacent surfaces does not exceed 80 K; a
temperature rise of 65 K may only be exceeded for a limited period of time.
6.1.9.1.1 The action of this safety device shall be such that once the gas supply to the burner has been
interrupted, it can only be re-established following a manual intervention.
6.1.9.1.2 The requirements of 6.1.5.1.5 and 6.1.5.2 shall be satisfied when the fan is stopped 5 min
before the end of the test period specified in the following clauses and these tests are continued up to
10 min after automatic interruption of supply to the burner(s), under the following test conditions:
for appliances with an oven having a special thermostat setting for cleaning, those of 7.3.1.5.2.3 test
no. 4.
For the purposes of these tests, the fan shall be stopped by preventing its rotation by a means which does not
interfere with nor cause premature operation of the safety device which automatically cuts off the gas supply
to the burner(s) in the case of a fault with the fan.
The maximum temperatures reached during the tests are used as a basis for verifying the requirements of
6.1.5.1.5.
It is also verified that the maximum temperatures of the support, walls and adjacent walls do not exceed
ambient temperature by more than 80 K during the tests and the requirements of 6.1.5.2 at the end of the test.
6.1.9.2 The following requirements are applicable to appliances fitted with a safety device which, in the
event of a fault in the operation of the fan, automatically reduces the heat input of the burner(s), so that the
maximum temperature rise of the supports, walls and adjacent surfaces does not exceed 80 K; a temperature
rise of 65 K may only be exceeded for a limited period of time.
6.1.9.2.1 The action of a safety device shall be such that a manual intervention is required, once the
heat input of the burner or burners has been reduced, in order to re-establish the nominal heat input.
6.1.9.2.2 The requirements of 6.1.5.1.5 and 6.1.5.2 shall be satisfied when the fan is stopped 5 min
before the end of the test period specified in the following clauses and these tests are continued up to
10 min after the automatic reduction of the heat input of the burner(s), under the following test conditions:
for appliances with an oven having a special thermostat setting for cleaning, those of 7.3.1.5.2.3, test
no. 4.
For the purposes of these tests, the fan shall be stopped by preventing its rotation by a means which does not
interfere with nor cause premature operation of the safety device which automatically reduces the heat input
of the burner(s) in the event of a fault with the fan.
The maximum temperatures reached during the tests are used as a basis for verifying the requirements of
6.1.5.1.5.
It also verified that the maximum temperatures of the support, walls and adjacent partitions do not exceed
ambient temperature by more than 80 K during the tests, and the requirements of 6.1.5.2 at the end of the
tests.
50
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
6.1.9.2.3 In addition, after the automatic reduction of the heat input of the burner(s), the requirements
of 6.3.1 and 6.3.2 shall be satisfied when the burners controlled by the device are tested under the
conditions of 7.3.3.1, 7.3.3.2.2 and 7.3.3.2.3 that require the use of a reference gas.
6.1.9.3 The following requirements are applicable to appliances for which the supports, walls and adjacent
surfaces undergo, in the event of a fault in the fan, a maximum temperature rise exceeding 80 K.
6.1.9.3.1 The appliance shall have either a fan fault indicator, or an automatic burner cut-out device.
a) Where the appliance is fitted with a fan fault indicator, this indicator shall be designed and constructed in
such a way that it indicates a fault in the fan when the appliance is subjected to the tests stated in
6.1.9.3.2.
The fan fault indicator, once activated, shall continue to give the indication corresponding to the fan fault in all
circumstances in which the fan should normally operate. Cancellation of this fault indication shall be possible
only following the use of a tool.
The indicator shall be installed in such a way that the fault indication is obvious for the user standing in front of
the appliance. In addition, the installation and maintenance instructions shall include all necessary information
regarding the indicator and the steps to be taken in the event of a fault in the fan.
b) Where the appliance is fitted with an automatic burner cut-out device, this device shall be designed and
constructed in such a way that it interrupts the supply to the burner or burners, with which the fan shall
normally operate, when the appliance is subjected to the tests mentioned in 6.1.9.3.2.
Once the supply has been interrupted, the burners shall be unable to operate before the appliance has been
repaired. This repair shall only be possible after the use of a tool giving access to the parts to be reset,
repaired or replaced.
6.1.9.3.2 The requirements of 6.1.5.1.3 and 6.1.5.1.4 shall be complied with, and also the
requirements of 6.1.5.2, but allowing a temperature rise limit of 120 K in place of the one stated, when the
appliance is used with the fan stopped under the following conditions:
for appliances with an oven having a special thermostat setting for cleaning, those of 7.3.1.5.2.3, test
no. 4.
For the purposes of these tests, the fan shall be stopped by preventing its rotation by a means which does not
interfere with nor cause premature operation of the safety device which automatically cuts off the gas supply
to the burner(s) in the case of a fault with the fan nor interfere with the operation of the fault indicator.
If the appliance is fitted with a device which cuts the supply to the burner(s) in the event of a fault in the
fan, the fan is stopped 5 min before the end of the specified test period and these tests are continued for
10 min after automatic cut-off of the supply to the burner(s);
if the appliance is not fitted with such a device, the fan is stopped from the start of the test.
The maximum temperatures reached during these tests are used as a basis for verifying the requirements of
6.1.5.1.3 and 6.1.5.1.4, and the 120 K limit for the supports, walls and adjacent surfaces. At the end of each
test, it is verified that the fan fault indicator or the cut-off device has operated.
6.1.9.3.3 The requirements of 6.1.5.1.5 shall be met when the appliance is tested, with the fan stopped,
under the following conditions:
for an appliance without an oven having a special thermostat setting for cleaning, those of 7.3.1.5.2.3,
test no. 5;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
51
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
for an appliance without an oven having a special thermostat setting for cleaning, the more severe of the
two following conditions:
For the purposes of these tests, the fan shall be stopped by preventing its rotation by a means which does not
interfere with nor cause premature operation of the safety device which automatically cuts off the gas supply
to the burner(s) in the case of a fault with the fan.
If the appliance is fitted with a device which cuts the supply to the burner(s) in the event of a fault in the
fan, the fan is stopped 5 min before the end of the specified test period and these tests are continued for
10 min after automatic cut-off of the supply to the burner(s);
if the appliance is not fitted with such a device, the fan is stopped from the start of the test.
The maximum temperatures reached during these tests are used as a basis for verifying the requirements of
6.1.5.1.5.
6.1.9.3.4 The requirements of 6.3.1 and 6.3.2 shall be satisfied with the fan stopped.
When the burners with which the cooling fan normally operates are tested under the conditions of 7.3.3.1,
7.3.3.2.2 and 7.3.3.2.3, only the reference gases are used.
Appliances having ovens with thermostats complying with EN 257:1992 or with thermostats incorporated in
multifunctional controls complying with EN 126 shall comply with the requirements of 6.1.10.1 or 6.1.10.2.
Appliances having ovens with other thermostats shall comply with the requirements of 6.1.10.2.
6.1.10.1 The requirements of 6.1.5.2 shall be satisfied under whichever of the following test conditions are
the most severe:
for an oven without a special thermostat position for cleaning, those of 7.3.1.5.2.3, test no. 56);
for an oven having a special thermostat position for cleaning, whichever of the following is more severe:
those of 7.3.1.5.2.3 test no. 57), but with the oven thermostat out of action and the oven temperature
controlled independently to give a maximum temperature during the test of (250 ) °C at the centre of
+4
0
the oven.
If the most severe condition is that with the thermostat out of action, it shall be verified that the requirements of
6.1.5.1.5 are met under the same test conditions.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
52
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
6.1.10.2 The appliance shall meet the requirements described in 6.1.10.2.1, 6.1.10.2.2 or 6.1.10.2.3 as
appropriate.
6.1.10.2.1 The requirements of 6.1.5.1.5 and 6.1.5.2 shall be satisfied under the test conditions of
7.3.1.5.2.3 test no. 58), but with the oven thermostat put out of action.
6.1.10.2.2 The following requirements are applicable to appliances fitted with a safety device which, in
the event of failure of the oven thermostat, automatically shuts off the gas supply to the burners, so that
the maximum temperature rise of the supports, walls and adjacent surfaces does not exceed 80 K.
The action of the safety device shall be such that once the gas supply to the burner has been interrupted, it
can only be re-established following manual intervention.
The requirements of 6.1.5.1.5 shall be satisfied under the conditions of 7.3.1.5.2.3, test no. 59), but with the
oven thermostat put out of action.
The maximum temperatures reached during the test are used as a basis for verifying the requirements of
6.1.5.1.5.
It is also verified that the maximum temperatures of the support, walls and adjacent surfaces do not exceed
the ambient temperature by more than 80 K during the test, and the requirements of 6.1.5.2 at the end of the
test.
6.1.10.2.3 The following requirements are applicable to appliances for which the maximum temperature
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
rise of the support, walls and adjacent surfaces exceeds 80 K in the event of oven thermostat failure.
a) For an appliance fitted with a thermostat fault indicator, this indicator shall be so designed and arranged
that it indicates an oven thermostat fault when the appliance is tested under the conditions given in
6.1.10.2.3.2.
When the thermostat fault indicator has been activated, it shall continue to indicate the existence of an oven
thermostat fault whenever the oven is required to operate.
Cancellation of this fault indication shall only be possible after the use of tools to gain access to the parts
which require replacement or re-setting.
The indicator shall be so positioned that it is obvious to the user standing in front of the appliance when the
thermostat fault is being indicated. In addition, the instructions for use and maintenance shall include all
necessary information on the purpose of the indicator and the action to be taken in the event of a thermostat
fault.
b) For an appliance fitted with an automatic burner shut-off device, the device shall be so designed and
arranged that it shuts off the burner, when the appliance is tested under the conditions given in
6.1.10.2.3.2.
Following shut off, further operation of the burner shall not be possible until the appliance has been repaired.
This repair shall only be possible after the use of tools to gain access to parts which require replacement or
re-setting.
8)9) For this test a tolerance of 10 K above the requirements of 6.1.5.2 is allowed.
53
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
those of 7.3.1.5.2.3, test no. 5, but with the oven thermostat out of action.
The maximum temperatures achieved during the test are used as a basis for verification of the requirements
of 6.1.5.1.3, 6.1.5.1.4, 6.1.5.1.5 and the 120 K limit for the support, walls and adjacent surfaces. At the end of
the test it is verified that any thermostat indicator or burner shut-off device has been activated.
When the hotplate burners are ignited under the conditions of 7.3.2.1, ignition and cross-lighting shall occur
smoothly within 5 s of turning the burner control to the full-on position or the ignition position, if it exists.
After ignition under these conditions, the flames shall be stable and quiet. A slight tendency to flame lift is
permitted on ignition but flames shall be stable 60 s after ignition.
When the burner taps are turned to their reduced rate positions under the test conditions in 7.3.2.1, the
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
hotplate burner flames shall not light back and neither shall they be extinguished.
When the oven door or the cupboard door(s) are opened and closed under the test conditions in 7.3.2.1, the
hotplate burner flames shall not light back and neither shall they be extinguished.
However, if there is a permanent ignition device or an automatic re-ignition device, extinction is allowed if
normal operation returns without any manual intervention 5 s after the movement of the door ceases.
When the appliance incorporates a multi-ring hotplate burner for which each ring of burner ports is controlled
independently by a means of a separate tap or control, the requirements of 6.2.1.1 shall be met with each ring
of burner ports being operated as if it were a separate burner.
When the appliance incorporates a multi-ring hotplate burner that is controlled by a single tap or control, the
requirements of 6.2.1.1 shall be met with this burner operating as described for other hotplate burners. In
addition, if such a burner is a multi-ring hotplate burner with sectional control it shall be verified under the
conditions of 7.3.2.1.4 that when the gas rate supplied to the supervised ring of burner ports is reduced to the
rate corresponding to that obtained when the tap or control is set to its lowest marked position, ignition and
cross-lighting at any unsupervised ring of burner ports occurs smoothly within 5 s of turning on the gas supply
to that ring of burner ports by means of the burner control.
For multi-ring hotplate burners with simple control it shall be verified under the conditions described in
7.3.2.1.4 that when its tap or control set to the lowest marked position for which ignition of the supervised ring
of burner ports is possible, ignition and cross-lighting at any unsupervised ring of burner ports occurs smoothly
within 5 s of ignition at the supervised ring of burner ports.
Uncovered multi-ring hotplate burners equipped with a single flame supervision device shall not be
extinguished under the test conditions given in 7.3.2.2 and 7.3.2.3 unless the extinction of the burner is
complete and the gas supply to the burner is shut off under the control of its flame supervision device.
54
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
6.2.2 Combustion
Under the conditions in 7.3.2.4.1, the volume content of the CO in the air- and water-free products of
combustion shall not exceed:
In addition, when the appliance has a mains electrical supply, and fluctuation of the supply can affect the
operation, ignition and/or the combustion, it shall be verified under the conditions described in 7.3.2.4.1, test
no. 5, that each hotplate burner ignites and continues to function during the test.
Moreover, under the test conditions described in 7.3.2.4.4, where the hotplate burners are supplied
individually with the limit sooting gas, yellow tipping is permitted if it does not result in a soot deposit 10 min
after a test vessel has been placed over the burner.
6.3.1.1 Oven
When an oven is ignited in a still atmosphere under the test conditions in 7.3.3.1.2, 7.3.3.1.3 and, where
applicable 7.3.3.1.9, ignition and cross-lighting shall occur smoothly within 5 s of turning the burner control to
the full on position, or the ignition position if it exists.
Following ignition under these conditions, the flames shall be stable and quiet. A slight tendency for the flames
to lift at the moment of ignition is allowed, but they shall be stable 60 s after ignition.
When the oven control is turned to the minimum position under the conditions in 7.3.3.1.4, the oven burner
flames shall not light back and neither shall they be extinguished.
When the oven door and, where applicable, the cupboard door(s) are opened and closed under the test
conditions in 7.3.3.1.5 and 7.3.3.1.6, the oven burner flames shall not light back and neither shall they be
extinguished.
However, if there is a permanent ignition device or an automatic re-ignition device, extinction is allowed if
normal operation returns without any manual intervention 5 s after the movement of the door ceases.
If an appliance with an oven is capable of being installed between two cabinets or built into a unit then under
the test conditions in 7.3.3.1.10, the oven burner flames shall not light back and neither shall they be
extinguished. However, if there is a permanent ignition device or an automatic re-ignition device, extinction is
allowed if normal operation returns without any manual intervention when the movement of the door ceases.
In addition, when the oven control settings are altered during the tests, the flames shall not be disturbed in a
way which would damage the appliance or risk compromising its safety of operation.
6.3.1.2 Grill
When a grill is ignited in a still atmosphere under the test conditions in 7.3.3.1.2, 7.3.3.1.3 and where
applicable in 7.3.3.1.7, 7.3.3.1.8 and 7.3.3.1.9, ignition and cross-lighting shall occur smoothly within 5 s of the
burner control being in the maximum position or in the ignition position, if there is one.
Under the test conditions in 7.3.3.1.2, 7.3.3.1.3, 7.3.3.1.7 and 7.3.3.1.9, the flames shall be stable and quiet. A
slight tendency for the flames to lift at the moment of ignition is allowed, but they shall be stable 60 s after
ignition.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
55
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
When the grill control is turned to the reduced rate position, if this exists, under the test conditions in 7.3.3.1.4,
the grill burner flames shall not light back and neither shall they be extinguished.
Under the test conditions in 7.3.3.1.8, there shall be no excessive flame instability in evidence.
In particular, the flames shall on no account extend outside the roof of the grill, but a certain amount of flame
movement and elongation is acceptable.
6.3.2 Combustion
When the ovens and grills are operating individually with a reference gas, under the conditions in 7.3.3.2.3,
the CO content of air and water vapor free products of combustion shall not exceed 0,10 % by volume, 15 min
after ignition.
When the appliance is supplied under the same conditions with the incomplete combustion gas specified in
7.1.1, the CO content shall not exceed 0,20 % by volume 15 min after ignition.
If, for an appliance having a mains electrical supply, fluctuation of this supply can affect the operation, ignition
and/or the combustion, then under the conditions of 7.3.3.2.4, when ovens and grills are operated individually,
the CO content of the air and water vapor free products of combustion shall not exceed 0,20 %, by volume,
15 min after ignition. Under the same conditions it shall be verified that each oven and grill burner ignites and
continues to function during the test.
When a grill is tested under the conditions in 7.3.3.2.6, the CO content shall not exceed 0,10 %, by volume
after 15 min previous operation at the nominal heat input.
When a high level grill is situated so that it might be affected by the operation of the hotplate or oven burners,
the CO content of the air and water vapor free products of combustion shall not exceed 0,20 %, by volume
when tested under the conditions of 7.3.3.2.7.
!When a grill, which is designed to be used only with the compartment door open can be operated with its
compartment door closed, is tested with its compartment door closed under the conditions of 7.3.3.2.8, the
maximum CO content of the air- and water vapour-free products of combustion shall not exceed 0,20 % by
volume.
NOTE This requirement is met if, 15 min after closure of the door under each of the test conditions given in 7.3.3.2.8,
the grill burner gas supply has been shut-off."
7 Test methods10)
7.1 General
The burners are tested with the gases indicated in Table 6 according to the category of the appliance (see
4.2).
10) This clause describes the methods of test which enable the requirements of Clauses 5 and 6 to be verified.
--`,,,,`,,`,,```,`,,`,``,`
56
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
ab
Table 6 — Test gases corresponding to the categories of appliances
I2L G 25 G 26 G 25 G 27 G 26
I3B/P, I3+ G 30 G 30 G 32 G 31 G 30
I3P G 31 G 31 G 32 G 31 G 31, G 32
II2E+3B/P,
II2E+3+
II2E+3P
a
For the test gases corresponding to the categories commercialised nationally or locally, refer to Table A.4.
b
Tests with limit gases are carried out with the injector and adjustment corresponding to the reference gas of the group
to which the limit gas used for the test belongs.
The compositions and main characteristics of the different test gases corresponding to the families or groups
of gases are given in Table 7, measured and expressed at 15 °C, resulting from the application of
EN ISO 6976:2005.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
57
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
a
Table 7 — Characteristics of the test gases dry gases, at 15 °C and 1 013,25 mbar
Gas families Test gases Designation Volume Wi Hi Ws Hs d
and groups
Composi-
MJ/m3 MJ/m3 MJ/m3 MJ/m3
tion
%
H2 = 59
N2 = 24
H2 = 23
Flame lift limit gas G 23 CH4 = 41,11 31,46 45,66 34,95 0,586
92,5
N2 = 7,5
Group L Reference gas and light G 25 CH4 = 86 37,38 29,25 41,52 32,49 0,612
back limit gas
N2 = 14
N2 = 13
Flame lift limit gas G 27 CH4 = 82 35,17 27,89 39,06 30,98 0,629
N2 = 18
H2 = 23
Flame lift limit gas G 231 CH4 = 85 36,82 28,91 40,90 32,11 0,617
N2 = 15
58
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Table 7 (continued)
3
The heat inputs for the test gases of the third family expressed in megajoules per cubic meter (MJ/m ) in
Table 7 can also be expressed in megajoules per kilogram (MJ/kg), dry gas, as in Table 8.
MJ/kg MJ/kg
G 30 45,65 49,47
G 31 46,34 50,37
G 32 45,77 48,94
The composition of the gases used for the tests shall be as near as possible to those given in Table 7. The
production of these gases shall be in accordance with the following rules:
the Wobbe index of the gas used shall be within ± 2 % of the value indicated in the table for the
corresponding test gas (this tolerance includes the error of the measuring equipment);
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
59
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
the constituents used to produce the mixtures shall have the following minimum degrees of purity:
nitrogen N2 99 %
hydrogen H2 99 %
methane CH4 95 %
However, these requirements are not obligatory for each constituent if the final mixture is of a composition
identical to that of a mixture that would have been obtained if the constituents given above had been used. To
make up a mixture, a gas already containing several constituents of the final mixture in convenient proportions
may be used as a starting point.
for tests carried out with the G20 and G25 reference gases, use a gas belonging respectively to group H,
group L or group E even if its composition does not comply with the above requirements, provided that,
after a possible addition of either propane or nitrogen, according to the situation, the final mixture has a
Wobbe index within ± 2 % of the value indicated in the table for the corresponding reference gas;
for making up the limit gases, take as a base gas instead of methane:
In all cases, the final mixture obtained by adding propane or nitrogen shall have a Wobbe index within ± 2 %
of the value given in Table 7, and the hydrogen content of this final mixture shall be as in Table 7.
In order to facilitate certain tests, the reference gases may be replaced by gases actually distributed in the
country or countries where the appliance is to be installed, provided that the following requirements are
fulfilled:
the distributed gases to be used for testing shall be of the same family and group as the specified
reference gas;
burners are adjusted to the same heat input as with the corresponding reference gas and the primary
aeration of the burners is so adjusted as to be close to that obtained with the corresponding reference
gas, either by using the aeration adjuster or by adjusting the supply pressure and/or by changing the
injector.
60
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The test pressures, i.e. the static pressures to be applied at the gas inlet connection of the appliance in
operation, are given in Table 9 (see also Table A.3).
a
Table 9 — Test pressures
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
1st family gas: 1a G 110, G 112 8 6 15
2nd family gas: 2H G 20, G 21, G 222, G 23 20 17 25
2nd family gas: 2L G 25, G 26, G 27 25 20 30
2nd family gas: 2E G 20, G 21, G 222, G 231 20 17 25
3rd family gas: 3 B/P G 30, G 31, G 32 b 25 35
29
G 30, G 31, G 32 50 42,5 57,5
3rd family gas: 3P G 31, G 32 37 25 45
G 31, G 32 50 42,5 57,5
2nd family gas: 2E+ G 20, G 21, G 222 20 17 25
G 231 d c 30
25 17
3rd family gas: 3+ G 30 b 20 35
29
(couple 28-30/37)
G 31, G 32 37 25 45
3rd family gas: 3+ G 30 50 42,5 57,5
(couple 50/67)
G 31, G 32 67 50 80
a
For the pressures corresponding to the gas distributed nationally or locally, refer to Table A.3.
b
The appliances in this category may be used without adjustment at the specified supply pressures of 28 mbar to 30
mbar.
c
See A.6.1.
d
This pressure corresponds to using a gas with a low Wobbe index but only the resistance to draught test 7.3.2.2 is
carried out at this pressure.
7.1.3.1 General
For the purposes of this European Standard, the burner is still deemed to be cold if it has not operated for
more than 5 s.
61
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
7.1.3.2.1 General
For all the tests, the appliance is fitted with the appropriate injector(s) for the family or group of gases to which
the test gas belongs. The primary air adjuster, if any, shall be adjusted according to the technical instructions.
Unless specified otherwise in the technical instructions, once the adjustments have been made for one
reference gas, they are not altered for the tests at the other pressures and with the other test gases of the
family or group for which the appliance is equipped and adjusted.
If on changing from butane to propane an adjustment of the primary air is specified in the technical
instructions, the tests using G 32 are carried out with the primary air adjustment appropriate to G 31. In
addition, the quality of combustion shall be checked in accordance with 7.3.2.4.1 (test no. 1) for hotplates and
7.3.3.2.3 for oven or grill burners, utilising G 31 as the reference gas and the supply conditions of 7.3.2.4.1
(test no. 1).
Unless specified otherwise for certain tests, any integral appliance regulator and any pilot gas rate adjusters
or reduced rate adjusters are set in accordance with the technical instructions with reference gas at normal
pressure for the family or group to which it belongs.
The adjustment instructions shall be included in the technical instructions. Their accuracy is checked by
carrying out test no. 3 in 7.3.1.2.1.2.
All the above adjustments are subject to the restrictions of 5.1.1 and 5.2.3.
Unless instructed to the contrary, a non-adjustable burner is considered to be operating at the nominal heat
input if, when supplied at the normal pressure with the reference gas of the category to which it belongs, the
heat input meets the requirements of 6.1.2.1.
Prior to all the tests which are specified to be carried out at nominal heat input, or at a specified heat input,
and taking account of the supply conditions, the local test temperature, the atmospheric pressure and the
measuring conditions (dry meter or not), the test laboratory shall ensure that the pressure upstream of the
injectors is such that the heat input can be obtained to within ± 2 % (by means of the adjusters or the
appliance pressure regulator if it is adjustable or the appliance supply pressure).
If the laboratory has to use a supply pressure p'n different from the normal test pressure pn to obtain a
nominal input to within ± 2 %, the test carried out on the burners individually at the minimum test pressures
pmin and maximum test pressures pmax shall be carried out at corrected pressures p'min and p'max so that:
Tests on several burners operating simultaneously shall be carried out at non-corrected test pressures.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
62
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
7.1.3.3.1.1 General
Unless specified to the contrary in the particular clauses, the tests are carried out with the appliance adjusted
to the lowest height specified by the manufacturer and placed in the test installation as described below (see
Figure 12).
7.1.3.3.1.2 Cookers
The test installation consists of vertical wooden panels 19 mm to 25 mm thick coated with matt black paint.
One panel is placed as close as possible to the rear face of the appliance. Another is placed at a distance
from one side of the appliance equal to the minimum declared by the manufacturer, but not exceeding
20 mm ; if the technical instructions do not forbid it, another panel is placed at the same distance from the
other side of the appliance.
The side panel(s) shall abut with the back panel. Any insulating material specified in the instructions shall be
placed between the panels and the appliance in accordance with the technical instructions.
The back panel is at least 1,80 m high and wide enough to project at least 50 mm beyond the sides of the
appliance.
The side panel(s) are the same height as the hotplate, not taking account of the height of the pan supports.
However, for an appliance with a shut-down lid intended to be installed, in compliance with the technical
instructions, so that the lid is the same height as the work surface of the adjacent furniture, the side panel(s)
shall be the same height as the shut-down lid in its closed position. The side panel(s) shall be deep enough to
project at least 50 mm beyond the front of the appliance.
The test installation is similar to that described in 7.1.3.3.1.2 except that the appliance is placed on a
horizontal support positioned against the back panel at such a height that the side panels are level:
with the hotplate or the shut-down lid (as specified above for cookers) in the case of table cookers and
independent hotplates;
The distance between the appliance and the side panels is the minimum indicated in the technical instructions.
The test installation is similar to that described in 7.1.3.3.1.2 except that the appliance is fixed to a back panel
which projects at least 150 mm beyond each side of the appliance.
The appliance is fixed, at the minimum distance specified in the technical instructions, above a 600 mm deep
horizontal panel, which extends from one side panel to the other.
Side panels, 600 mm deep, are installed at each side of the appliance at the minimum distance(s) which shall
be indicated in the technical instructions.
63
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Unless specified to the contrary in the particular clauses, the tests are carried out with the appliance adjusted
to the lowest height specified by the manufacturer, and placed in the test installation as described below (see
Figure 12).
The test installation comprises 3 vertical wooden panels 19 mm to 25 mm thick coated with matt black paint.
One panel is placed as close as possible to the rear face of the appliance the other two are placed against the
sides of the appliance.
The side panels shall abut with the back panel. Any insulating material specified in the instructions shall be
placed between the panels and the appliances in accordance with the technical instructions.
The back panel is at least 1,80 m high and wide enough to project at least 50 mm beyond each side of the
appliance.
The side panels are the same height as the hotplate, not taking account of the height of the pan supports.
However, for an appliance with a shut-down lid intended, according to the technical instructions, to be installed
so that the lid is the same height as the work surface of the adjacent furniture, the side panels shall be the
same height as the shut-down lid in its closed position. The side panels shall be deep enough to project at
least 50 mm beyond the front of the appliance.
The tests are carried out with the appliance in its building-in unit comprising either a work top linking two
cupboards, one on each side of the appliance (see Figure 2) or a work top and two side panels representing
the two furniture units.
The construction of the unit for building-in and the horizontal separation, if it exists (see Figure 13) shall be in
accordance with the critical dimensions given in the technical instructions.
If the technical instructions specify the use of a panel to close the space at the front between the top of the
appliance and the underside of the work top, this shall be provided.
The work top shall be (30 ± 5) mm thick and project by the maximum value given in the instructions beyond
the front of the oven. All other panels shall be at least 15 mm thick.
The back panel shall be at least as wide as the gap between the two cupboards and shall be at least 1,80 m
high.
The appliance is installed as close to the base of the building-in unit as the technical instructions allow.
7.1.3.3.3.1 General
Unless specified to the contrary in the particular clauses, the tests are carried out with the appliance installed
according to the technical instructions in its building-in unit made of wood (see Figure 13).
If the unit specified in the technical instructions does not comply with the requirements of ISO 5732 the
manufacturer shall specify in his instructions the critical dimensions of the unit. He shall supply the
laboratory with a unit with the critical dimensions;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
64
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
if the unit specified in the technical instructions complies with the requirements of ISO 5732, it does not
have to be supplied by the manufacturer. Its dimensions shall correspond with the critical ISO dimensions,
taking account of the tolerances.
If the manufacturer allows several options for ventilating and evacuating the products of combustion, the tests
are carried out for every option.
Unless specified otherwise in the individual clauses, the tests are carried out with all the unit doors closed.
Any gaps allowing air to pass through between the side panels, the support and the back panel are sealed
with adhesive tape.
According to the type and/or method of installation for the appliance, the unit shall meet the following
requirements where appropriate.
a) Ovens and oven/grills intended for installation below the work top
The building-in unit shall comprise an upper panel (work top), a bottom panel and two side panels. For test
purposes, the unit does not have a back panel but it is placed against a back panel as described in 7.3.1.5.1.3.
The construction of the unit shall be such that the dimensions of the space for installing the appliance are the
critical values specified in the technical instructions. If the manufacturer specifies the use of a unit complying
with the requirements of ISO 5732:1978, then the unit shall be of the critical dimensions given in
ISO 5732:1978, taking account of the permitted tolerances.
The upper panel (work top) shall be (30 ± 5) mm thick and shall project beyond the front of the appliance by
the maximum distance given in the technical instructions. All other panels shall be at least 15 mm thick.
b) Ovens and oven/grills designed to be built into a tall kitchen unit (see Figure 2; class 3, independent oven)
The specified unit shall meet the requirements of 7.1.3.3.3.2 a) except that the thickness of the top panel shall
not be less than 15 mm. The upper and lower panels shall have the critical dimensions specified by the
manufacturer.
If the appliance can be installed in a kitchen unit having doors, the test unit shall be supplied with doors of the
largest surface area in accordance with the technical instructions.
c) Hotplates
The unit for building-in comprises a panel (work top) as described hereafter, fitted onto a kitchen unit.
The work top shall be (30 ± 5) mm thick and shall have an opening of the minimum size given in the technical
instructions for installing the appliance. This opening shall be located so that when the appliance is installed,
the distance between the appliance and the back of the work top is the minimum given in the instructions.
For an appliance of width less than 600 mm, the work top is fixed on a unit 600 mm wide with a single door.
For an appliance of width 600 mm or more, the unit for building in shall be of the minimum width specified by
the manufacturer, which shall not be less than 600 mm. The unit shall have one door for each 600 mm width.
The kitchen unit shall have a back panel at least as wide as the unit. It shall be possible to remove this panel
in order to carry out the tests in 7.3.1.5. If the unit does not have a sealed base, any gaps allowing air to pass
through are sealed with adhesive tape.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
65
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The side and back panels shall not be less than 15 mm thick.
When specified in the technical instructions, the kitchen unit shall be fitted with a horizontal partition under the
hotplate, at a distance from the surface of the work top which is not less than that specified in the technical
instructions, which shall not exceed 150 mm (see Figure 13).
The building-in unit shall comprise an upper panel (work top), a bottom panel and two side panels. For test
purposes, the unit does not have a back panel.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The construction of the building-in unit shall be such that the dimensions of the space for installing the
appliance are the critical dimensions specified in the technical instructions. If the manufacturer specifies the
use of a building-in unit complying with the requirements of ISO 5732:1978, then the unit shall be of the critical
dimensions given in ISO 57321978, taking account of the tolerances allowed.
The work top shall have an opening of the minimum size given in the technical instructions for installing the
appliance. This opening shall be located so that when the appliance is installed, the distance between the
appliance and the back of the work top is the minimum given in the instructions.
The work top shall be (30 ± 5) mm thick and shall project beyond the front of the appliance by the maximum
distance given in the instructions. All the other panels shall be at least 15 mm thick.
The building-in unit shall be placed in the test installation according to the installation instructions supplied by
the manufacturer in the technical instructions.
7.1.4 Pans
Where the use of a pan is required on a hotplate burner or an electric cooking plate, a pan as described below
is used, unless otherwise indicated:
220 mm diameter pan, filled with 2 kg of water at ambient temperature, is used on a covered and
uncovered hotplate burner having a nominal heat input not exceeding 4,2 kW and on a fish burner of
useful length equal to, or less than, 140 mm;
300 mm diameter pan, filled with 3 kg of water at ambient temperature, is used on a covered and
uncovered hotplate burner having a nominal heat input greater than 4,2 kW;
a pan, filled with 2 kg of water at ambient temperature, is used on a fish burner of useful length greater
than 140 mm. This pan shall have a height of 140 mm and a width and length sufficient to overlap all
sides of the burner by at least 60 mm and at most 80 mm. A fish pan conforming to these dimensions
shall be supplied by the manufacturer to the laboratory;
a pan, which shall be in conformity with the instructions for use and maintenance, is used on a burner
designed to be used exclusively with convex-based pans;
a pan and water content given in C.2 are used on an electric cooking plate;
a permanent griddle and a temporary griddle, when it is being used as a griddle, are tested without a pan.
Pans are placed on the geometrical centre of the cooking area, unless otherwise indicated.
Where the use of a pan is required simultaneously on each of the hotplate burners and the electric cooking
plates, a distance of at least 10 mm shall be provided between the side surface of the pan and:
66
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
If for an appliance that does not have any hotplate burners with a nominal heat input greater than 4,2 kW,
using the pans described for individual tests for the burners, this arrangement is impossible, a pan of diameter
given in C.1 is used on each of the burners which allows this arrangement to be fulfilled. The special pans
(convex-based, rectangular) used in the individual tests are retained for the simultaneous tests.
In the case of an appliance with one or more hotplate burners having a nominal heat input greater than 4,2 kW,
pans are initially placed on any other hotplate burners and electric cooking plates. A distance of at least
10 mm shall be provided between the side surface of each pan and:
In addition no pan shall overlap the edges of the hotplate. If, using the pans described for individual tests for
these burners, this arrangement is impossible, a pan of diameter given in C.1 is used on each of the burners
which allows this arrangement to be fulfilled. Pans are then placed on each of the burners having a nominal
heat input greater than 4,2 kW. If, using the 300 mm diameter pans described for individual tests for these
burners, this arrangement is impossible, a pan of diameter given in C.1 is used on each of the burners which
allows this arrangement to be fulfilled. The special pans (convex-based, rectangular) used in the individual
tests are retained for the simultaneous tests.
A permanent griddle and a temporary griddle, when it is being used as a griddle, are tested without a pan.
Pans are placed on the geometrical centre of the cooking area, unless otherwise indicated.
a) for an oven with a thermostat, the control handle is positioned in order to obtain an average temperature
of 230 °C at the centre of the oven using the reference gas at the normal test pressure, or using the
nominal voltage;
b) for an oven without a thermostat, the control handle is set at the highest position until a temperature of
about 230 °C is obtained at the centre of the oven using the reference gas at the normal test pressure, or
at the nominal voltage. The control handle is then set to the position allowing a temperature of 230 °C to
be maintained;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
1. if the oven temperature control is not continuous in action, the control handle is set in the position
corresponding to the nearest possible temperature above 230 °C;
2. if a temperature of 230 °C at the centre of the oven cannot be achieved, the control handle is set to the
position corresponding to the maximum temperature;
d) for grills, the control handle is set to the position corresponding to the maximum temperature.
67
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Unless otherwise indicated, an appliance having a mains electrical supply is supplied at the nominal voltage.
In the case of appliances incorporating multi-ring hotplate burners the test methods requiring the operation of
hotplate burners shall be carried out as follows:
appliances having multi-ring hotplate burners with simple control. Unless otherwise stated such tests shall
be carried out with the multi-ring hotplate burner(s) operating as described for other hotplate burners;
appliances having multi-ring hotplate burners with sectional control, each supplied from a single gas tap.
Unless otherwise stated such tests shall be carried out with the multi-ring hotplate burner(s) operating as
described for other hotplate burners;
appliances having multi-ring hotplate burners with sectional control, each ring of burner ports supplied
from a separate gas tap. Unless otherwise stated such tests shall be carried out with each ring of burner
ports operating as if it were a separate hotplate burner.
7.2.1 Strength
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
7.2.1.1 General
The requirements of 5.1.4 are verified in the course of the following tests.
The cooker is placed on a horizontal plane and is held or retained in position there, e.g. by means of stops.
None of the appliance components are removed if this could affect the strength of the cooker body. However,
particular components may be removed if this is necessary to ensure that the test correctly assesses the
strength of the cooker body.
A force, the horizontal component of which is 500 N ± 10 % is then applied suitably distributed to the upper
part of the front in the direction from front to back (see Figure 3).
precautions are taken to avoid deterioration, in the area where the force is applied, which could impair the
normal operation of the appliance;
if deterioration cannot be avoided, the damaged pieces are replaced by identical new ones before
carrying out the other tests.
Figure 3 shows the arrangement for carrying out the test: the sum of the horizontal components of the forces
applied by the dynamometers shall be 500 N ± 10 %.
A mass m, centred above each of the burners, is placed simultaneously on the pan support (grid or plate) so
that:
68
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
m = m1 + m’2 (2)
where
m1 = (5 ± 0,2) kg;
m2' is a mass chosen from a series of masses with the following nominal values:
The test masses m2' shall have a value within ± 4 % of the nominal value.
For m’2 a value is chosen from the series which is just greater than the value m2 calculated according to the
following equation:
where
The contact area of the mass m1 on the grid or plate is flat and has a diameter of (180 ± 4) mm (see Figure 4).
Masses m appropriate for each burner are put into position quickly and carefully.
Once all the burners are fully laden, the weights are left in position for 5 min and then the weights are
removed carefully.
7.2.1.4 Strength of surfaces of glass ceramic or glass parts not from thermally toughened soda-
lime glass
Compliance with 5.1.2.2 shall be checked by applying blows to the appliance by means of the spring operated
impact test apparatus as described in EN 60068-2-75, test Ehb. The release cone of the test apparatus shall
be applied perpendicular to the surface tested.
The appliance is rigidly supported and three blows are applied to every point of the surface of the glass
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
ceramic components that is likely to be weak. Lids and doors shall be tested in closed position.
The blows have an impact energy of (0,5 ± 0,04) Nm perpendicular to the surface and are not applied to
places within a distance of 20 mm from rims (e.g. knobs, burners), edges or facettes.
69
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
7.2.1.4.2 Verification of the strength of the hotplate surfaces of glass or glass ceramic against
thermal stress
Each burner of the glass or glass ceramic hotplate is supplied with one of the reference gases at the normal
pressure corresponding to the appliance category. The burners are operated simultaneously at full rate, until
steady conditions are established. Then the burners are shut-off.
NOTE Steady conditions are deemed to have been achieved when the temperature of the glass or glass ceramic
surface does not vary by more that 1 K in 15 min.
A quantity of 1,0 litres to 1,1 litres of cold water having a temperature of 15°C ± 5°C is poured steadily and
uniformly over the glass or glass ceramic hotplate, and 1 min later all excess water is removed and the
surface wiped dry. Compliance with 5.1.2.2.2 is then checked.
7.2.2.1 General
The tests for the strength of the oven door or of the oven fitted with a grill, as well as the appliance tilting tests,
are carried out immediately after the initial soundness test carried out on the appliance in the as-delivered
condition in conformity with 7.3.1.1.1.
Doors with bottom horizontal hinges are opened completely. It is verified, using the device shown in Figure 5,
that the requirements of 5.2.9.1.1 are met, firstly without a load, then, when a load as specified in 5.2.9.1.1 is
placed smoothly on the surface of the door so that its centre of gravity is vertically above the geometric centre
of the door. The contact surface of the load is such that no damage shall result from it to the door.
Doors with a vertical hinge are opened to an angle of 90°, the load as specified in 5.2.9.1.1 is placed in the
centre of the top edge of the door.
If an appliance has two ovens, the tests are carried out successively. If the two ovens are identical, they are
both regarded as large ovens.
The appliance is placed on a horizontal surface with the shutdown lid, if it exists, closed and the ovens or grills
empty.
Doors with bottom horizontal hinges are opened completely and a load conforming to the requirements of
5.2.9.1.2 is placed smoothly on the surface of the door so that its centre of gravity is vertically above the
geometric centre of the door. The contact surface of the load is such that no damage shall result from it to the
door.
Doors with a vertical hinge are opened to an angle of 90° and a mass as specified in 5.2.9.1.2 is then placed
carefully in the middle of the top edge of the door. This test is repeated with the door open as much as
normally possible but without the opening angle exceeding 180°.
For appliances with more than one door, the tests are carried out under the same conditions for each door
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
separately.
70
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
a) A mass as shown in Table 4 is uniformly distributed over the useful surface of each of the oven and grill
accessories; the requirements of 5.2.9.1.3 a) are checked for each item in turn.
The hot sliding test is carried out in accordance with 7.1.5, with one of the reference gases for the category to
which the appliance belongs:
c) if the grill pan has a handle, the following test is carried out:
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
1) the grill pan is filled with water to 25 % of its capacity. It is lifted up and the water then poured out;
If hinged parts of the hotplate, that are intended to be raised, are not fitted with a mechanical means of
preventing them from falling accidentally, the following tests are carried out under the installation conditions in
7.1.3.3:
the shut-down lid is fully raised and then brought back by 30 mm, measured at the extremity of the lid;
with the shut-down lid in the fully raised position, the pan supports are raised, then brought back by
20 mm;
with the shut-down lid and pan supports in the raised position, the spillage trays are fully raised, then
brought back by 20 mm.
In order to verify the requirements of the last paragraph of 5.2.8.1, a 200 mm diameter pan (in accordance
with Table C.1) is placed flat on the pan supports of the hotplate. It is placed at the extreme position(s) which,
at the same time, retains its stability on the pan supports and is as close as possible to the shut-down lid in its
fully open position.
The requirements of 5.2.12.2 shall be checked in the first instance by examining the appliance construction
and that of its controls in order to determine the circumstances under which un-burnt gas can be admitted to
the appliance where, after some delay, it could be ignited by any source of ignition on the appliance.
During the examination of the appliance, a number of additional factors shall be taken into consideration, the
application of which is dependent on the use of auxiliary energy and the means of ignition employed. These
factors are given in the Table 10.
1) appliances without electricity supply: item A), if appropriate, and item B);
2) appliances with electricity supply and manual ignition: items A), B) and C);
71
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3) appliances with delayed ignition of the oven: items A), B), C) D) and E).
Table 10 — Additional factors to be taken into consideration for testing the safety of burners in the
appliance
Item Factors
A) a
The possibility that controls may be operated incorrectly or out of sequence
b
B) The possibility of ignition by means of some other ignition source on the appliance, e.g. via flue duct
C) Interruption and restoration of the electrical supply
D) Failure of a clock, timer or programmer
E) Operation of any device which would enable the appliance to be used in the event of loss of the
electricity supply: items A) and B) are considered whilst this device is in operation
a
The factor A) is considered when the user is required to carry out several manual actions when putting the appliance
into operation e.g. when using an oven for automatic cooking. In such cases, the examination ensures that accidental
mistakes or omissions when carrying out these actions would not create a dangerous accumulation of un-burnt gas in the
appliance. Factor A) is not intended to apply to manual ignition where the action taken by the user is continuous (see 5.2.6).
b
The factor B) includes the possibility of ignition resulting from operation of an electric oven in the same compartment.
When the appliance has a manual ignition device that does not require continuous operation of the device or
an automatic device with no limit on the ignition time, then, in order to assess the possibility of un-ignited gas
becoming ignited, it is assumed that this un-ignited gas is released for an unlimited period.
If, after this examination, delayed ignition of a potentially dangerous accumulation of gas is not possible, the
requirements of 5.2.12.2 are deemed to be satisfied.
7.2.3.2 Test
If, after the examination of 7.2.3.1, a delayed ignition of a potentially dangerous accumulation of gas seems
possible, the following test is carried out using the reference gas or gases at the normal test pressure.
The ignition device or any other means of ignition is operated after a short delay. At the end of this test, the
gas supply to the burner is interrupted, the compartment is ventilated and the appliance cooled to room
temperature.
The test is repeated several times gradually increasing the delay until the most critical delay is reached. After
each ignition test the compartment is ventilated and the appliance is cooled to room temperature.
The requirements of 5.2.12.2 are deemed satisfied if, on reaching the most critical delay:
However, if at any time during the delayed ignition tests, one of the above phenomena is observed, the tests
are halted and the appliance is deemed not to comply with the requirements of 5.2.12.2.
For these tests, devices for remotely controlling the ignition and the gas supply to the burner shall be used.
7.2.4 Appliances with a glass lid having a device for shutting off the gas to the hotplate burners
The appliance is installed in accordance with the requirements in 7.1.3.3 and supplied with the reference gas
with the lowest Wobbe index of the category, in accordance with 7.1.1.1 under the normal test pressure.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
72
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
It is adjusted in accordance with 7.1.3.2. If necessary, it is supplied with electricity at the rated voltage.
With the lid open to the maximum permitted by the test installation, all the burners of the hotplate are ignited
and operate for 5 min, with their control devices at their highest setting. The following tests are then carried
out:
1) the lid is lowered until it has gone through an angle of 5° from its fully open position. With the lid in
this position, it is verified that the requirements of 5.2.8.1 (paragraph 10, subdivision b) 1)) are
respected;
2) the lid is lowered until it has gone through an angle of 45° from its fully open position. 5 s after the lid
has reached this position, it is verified that the requirements of 5.2.8.1 (paragraph 10, subdivision b)
2)) are respected.
The appliance is installed in a room in which the ambient temperature does not vary by ± 2 °C during the
maximum period permitted by the oven programmer.
Using each of the reference gases at supply pressure, each oven pilot is adjusted in accordance with the
technical instructions.
The test starts when the appliance has reached thermal equilibrium, at the ambient temperature. The oven
pilot is ignited and the programmer is set to the position giving the maximum delay time.
The temperature at the centre of the oven and the ambient temperature are measured by means of
thermocouples and recorded continuously. The appliance and the thermocouple measuring ambient
temperature are protected from the effects of sun and draughts.
The test continues for the maximum period permitted by the programmer.
Using the temperature recording, a period of 1 h is chosen during which there are the fewest fluctuations in
the oven temperature and ambient temperature.
The difference between the oven temperature and ambient temperature is then determined by the average of
the temperatures measured during this 1 h period.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
7.3 Verification of performance characteristics
7.3.1.1 Soundness
The gas carrying parts are tested under the following conditions:
test no. 2: With all taps in the "on" position, the injectors of burners and pilots temporarily blocked and any
shut-off devices, for example the valves of flame supervision devices, where present, in the open position.
For the tests, the pressure upstream of the appliance is adjusted to 150 mbar.
73
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
at the end of all the tests to which the appliance is subjected with its original equipment without changing
any parts (injectors, pilots etc.);
after the five disconnections and re-assemblies described in 5.1.5 and carried out after the above test.
The leakage shall be measured in such a way that the accuracy of measurement is within
3
0,01 l/h (0,01 dm /h).
7.3.1.2.1.1 General
a) The nominal heat input is verified by using the reference gas or gases indicated in 7.1.1.1 and 7.1.3
depending on the category of the appliance, at the appropriate test pressures defined in 7.1.2
corresponding to the pressure data on the appliance (see 8.1) and using the corresponding injectors.
The measuring equipment shall enable the rate to be determined to an accuracy of ± 1,7 %.
The nominal heat input Qn indicated by the manufacturer is given by one of the following equations:
Qn = 0,278 Mn ⋅ Hs (4)
or :
Qn = 0,278 Vn ⋅ Hs (5)
where
Qn is expressed in kilowatts;
Mn is the mass flow rate of dry gas under reference conditions corresponding to the nominal heat
input in kilograms per hour; --`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Vn is the volume rate of dry gas under reference conditions corresponding to the nominal heat
input in cubic meter per hour;
Hs is the gross calorific value of the reference gas in Tables 7 and 8, given in megajoules per
cubic meter or megajoules per kilogram.
b) The mass (Mn and Mo) and volume (Vn and Vo) inputs correspond to a measurement and flow of the
reference gas, under reference conditions, i.e. assuming a dry gas at 15 °C and under a pressure of
1 013,25 mbar. In practice, the values obtained during the tests do not correspond to these reference
conditions, they shall therefore be corrected in order to bring them to the values which would actually
have been obtained if these reference conditions had been achieved during the tests, at the injector outlet.
The corrected mass flow rate is calculated using the following formula, according to whether it has been
determined by weighing or on the basis of a volume rate:
determination by weighing:
74
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Mo 1 013,25 + p 273,15 + t g d r
= ⋅ ⋅ (6)
M pa + p 288,15 d
Vo 1 013,25 + p p a + p 288,15 d
= ⋅ ⋅ ⋅ (7)
V 1 013,25 1 013,25 273,15 + t g d r
The corrected mass flow rate is calculated using the following equation:
Mo = 1,226 Vo ⋅ dr (8)
where
Mo is the mass flow rate of dry gas which would have been obtained under reference conditions
(see 3.1.3) in kilogram per hour;
M is the mass flow rate obtained under test conditions in kilograms per hour;
Vo is the volume rate of dry gas which would have been obtained under reference conditions (see
3.1.3) in cubic meter per hour under the same conditions;
V is the volume rate obtained and expressed under test conditions in cubic meter per hour;
d is the relative density of the dry (or wet) test gas relative to dry air;
dr is the relative density of the dry reference gas relative to dry air.
These equations shall be used to calculate, from the mass input M or volume input V measured during the test,
the corresponding rates Mo or Vo which would have been obtained under reference conditions.
It is these values Mo and Vo which shall be compared with the values Mn and Vn calculated from the nominal
heat input using the equations given in a) of this subclause.
If a wet meter is used or if the gas used is saturated, the value d (relative density of dry gas in relation to dry
air) shall be replaced by the value of the relative density of the wet gas dh given by the following equation:
( p a + p − p ws )d + 0,622 p ws
dh =
pa + p (9)
where
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
75
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
5. 262
p ws =exp 21, 094− (10)
273,15+t g
NOTE In the case of 2nd family gases, this correction is negligible.
The measurements are taken with the burner operating under the following conditions.
hotplate burners:
with the appliance at ambient temperature, the burner is ignited and operated for 10 min;
measuring begins at the end of the tenth minute and finishes at the latest at the end of the thirteenth
minute, or when the highest number of complete revolutions of the meter have been made before the
end of the thirteenth minute. The measurement shall be taken over at least one complete revolution
of the meter.
measuring begins from ignition, with the thermostat or control device at the maximum setting and
with the door open, and ends at the latest at the end of the fifth minute or when the highest number
of complete revolutions of the meter have been made before the end of the fifth minute.
grills:
the burner is ignited and operates for 10 min, with the control device at its highest setting and the
door open;
measuring begins at the end of the tenth minute, and ends at the latest at the end of the thirteenth
minute, or when the highest number of complete revolutions of the meter have been made before the
end of the thirteenth minute.
the heat input is measured for each reference gas supplying the appliance at a corresponding normal
test pressure. The values obtained shall comply with the requirements of 6.1.2.1.
test no. 1
With the adjuster in the maximum flow position, the supply pressure is adjusted to the minimum value.
test no. 2
This test is carried out immediately after test no. 1 without cooling down the appliance. With the
adjuster in the minimum flow position, the test pressure is adjusted to the maximum value.
76
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
If the adjustment of the gas rate is made by varying the pressure upstream of the injector, these
verifications are carried out with gases G20, G25, G110.
However, if the adjustment is made by varying the cross-section of the injector, test no.1 is only
carried out with the reference gas with the lowest Wobbe index. It is verified with the reference gas
with the highest Wobbe index, under the corresponding normal test pressure, that the injector size
corresponds to the nominal heat input in accordance with the requirements of 6.1.2.1.
test no. 3
The burner is adjusted according to the manufacturer's instructions under normal pressure. Using the
reference gas or gases under normal test pressure, it is verified that the heat input complies with the
requirements of 6.1.2.1 which apply to burners which are not fitted with a gas rate adjuster.
7.3.1.2.2.1 General
The burner is supplied according to its category with the reference gas or gases in accordance with 7.1.1.1
and 7.1.3.2, and at the normal test pressure given in 7.1.2.
The same vessels are used as for the measurement of nominal heat input.
The equations given in 7.3.1.2.1.1 for correcting the input values obtained during testing are applicable for
verifying the requirements of 6.1.2.2.
After operation under the conditions described below, the tap handle is moved to the reduced rate or minimum
temperature position:
The measurement is taken after 10 min of operation at nominal heat input, or immediately after the
measurement for obtaining nominal heat input.
b) oven
The tests designed to verify the opening and extinction delay times of the flame supervision devices specified
in 6.1.3 are carried out with the appropriate reference gas" corresponding to the appliance category, at the
normal test pressure. With these supply conditions, the appliance is first adjusted to its nominal heat input,
where adjusters are permitted.
Any pilot gas rate adjuster is adjusted as specified in the technical instructions.
77
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
After these adjustments, the appliance is shut off until it is cooled to ambient temperature. The gas supply is
restored and any pilot is lit. The opening time is that between the moment when the gas is lit at the pilot or
main burner (if there is no pilot) and that when the flame supervision device allows admission of the gas to the
burner without manual interruption.
At the end of test no. 2 of 7.3.2.4.1 for hotplate burners or for the oven and grill burners the tests in 7.3.3.2.3
that require the use of the reference gases, the extinction delay time is measured between the moment when
the pilot if any and burner are purposely extinguished by shutting off the gas supply and the moment when,
after immediately restoring the supply, the flow of gas controlled by the supervision device ceases through the
action of this device.
The tests designed to verify the operating characteristics of pilot flame supervision devices are carried out
using each of the reference gases at maximum and minimum pressures, verifying in each case that the flame
supervision device only opens or remains open when ignition is possible or has taken place satisfactorily
when following the manufacturer's instructions for ignition.
Test no. 1
With the appliance cold, reduce the gas rate to the pilot to the minimum energy required to keep open the gas
supply to the burner. Check that the burner is correctly ignited by the pilot.
Test no. 2
After heating the oven to a stable temperature in accordance with 7.1.5, close the oven tap and after a period
of 3 min check ignition with the actuating flame of the flame supervision device reduced to the most critical
heat input found in the previous test.
Test no. 3
In the case of pilots with several flame ports susceptible to blockage, the previous tests are repeated with all
the holes blocked except for the one which supplies the actuating flame for the sensing element of the flame
supervision device.
The appliance is first supplied with reference gas and then with the light back limit gas, or gases, for the
category to which the appliance belongs, using the appropriate injector. The maximum heat input at which
each gas will burn either at the injector or inside the burner is determined in the following way:
the gas is intentionally lit at the injector at normal test pressure (see 7.1.2), if necessary after temporary
removal of the burner head and also, if possible, at the burner head;
if combustion cannot be maintained at the injector or within the burner when the burner operates at its full
rate, the test is carried out by reducing the pressure to a point where combustion can be maintained, but
without, however, lowering the pressure below the minimum test pressure.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
78
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
If a reduced rate position is provided on the taps, and if the preceding test has not allowed combustion to be
maintained at the injector or within the burner, the heat input is reduced by turning the tap towards the
reduced rate position until the point is reached where combustion can be maintained in the injector or inside
the burner.
The test for resistance to overheating is then carried out supplying the appliance with the gas which can burn
at the highest rate at the injector or inside the burner, leaving the flame to burn under these conditions for
15 min.
If an appliance has hotplate burners, an additional test is carried out with reference gas(es) at normal test
pressure.
Each hotplate burner is operated according to the instructions for use and maintenance with its control set in
the reduced rate position.
The burners are operated simultaneously for 1h with no pan over them.
The test is carried out with reference gas or gases for the appliance category, supplied at normal test pressure.
Each burner having a body comprising several parts is ignited with its taps or thermostat in the fully open
position.
A suitable means (e.g. a match, a mobile ignition burner) is then used to search for gas leaks from the joints of
the assembly which could be ignited.
If necessary, components other than those of the burner may be removed, provided that this does not alter the
test conditions.
The tests are carried out with reference gas(es) of the appliance category at normal test pressure.
Each burner is first tested at its nominal heat input (see 7.1.3.2), then under the following conditions:
Hotplate burners
in the position giving the value indicated by the technical instructions for a needle type tap.
Oven burners
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
79
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The thermostat or tap is then moved to the position corresponding to the minimum temperature.
Grill burners
When each burner is operated under the conditions described above, a combustible gas detector is used to
search for un-burnt gas in the parts of the appliance where such gas could accumulate.
The requirements of 6.1.4.2.2 are satisfied if the maximum gas concentration in the air does not exceed
0,025 % by volume.
The concentration of gas in the air shall be determined to an accuracy of 0,005 % of the volume of the sample.
Care shall be taken to ensure that the sampling method used does not affect the flow of gas and air inside the
burner. In particular, the sampling probe shall not be placed against the air inlet or burner body.
If the air is adjusted by closing it off inside the burner mixing tube, the test is carried out with this device
adjusted to its maximum closed position.
The test is carried out in calm air and on each burner individually.
With the burner supplied with the reference gas G20, the requirements of 6.1.4.3 shall be verified under the
following conditions:
Hotplate burners:
Operate the burner initially for 10 min at full rate at normal test pressure;
The burner tap is moved at normal speed to its reduced flow position and the appliance operates for 60 s
under these conditions;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Oven burners:
The burner is operated under normal test pressure with the thermostat in maximum position, or if there is
no thermostat, with the tap set to the fully open position;
After 30 min of operation, the control device is moved at normal speed to the position corresponding to
minimum temperature and the appliance operates 60 s under these conditions;
Grill burners:
Operate the burner initially for 10 min at full rate at normal test pressure;
The burner tap is moved at normal speed to its reduced rate position, if any, and the appliance operates
for 60 s under these conditions. If the reduced rate position does not exist, operation is maintained at full
rate;
80
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
7.3.1.5 Heating
For these tests, the appliance is placed in the test installation specified in 7.1.3.3, but with the following
alterations:
Unless otherwise indicated, if additional or replacement panels are specified, they shall be made of 19 mm to
25 mm thick wood and coated with matt black paint.
Temperature measurement on the panels is limited to the hottest zones with the thermocouple at the centre of
a square of sides 100 mm on each of the panels. The thermocouples are introduced from the outside so that
their junctions are 3 mm from the surface facing the appliance. Additional thermocouples may be added in
areas susceptible to high temperatures.
In addition, the following supplementary installation conditions shall be complied with according to the class
and subclass of the appliance.
a) For all appliances with a hotplate, an additional panel is placed vertically at the side of the appliance
which produces the greater heating effect, at the minimum distance (see X1 in Figure 12) indicated in the
instructions. This panel shall be of a sufficient depth to extend from the back panel to at least 50 mm
beyond the front and of a sufficient height to extend from the work top to the top of the back panel. The
gap between the lower panel and the upper panel shall be filled in by a horizontal panel.
b) For wall-mounted grills, additional panels are placed on each side of the appliance at the minimum
distance indicated in the technical instructions. These panels are 600 mm deep and extend at least from
the horizontal panel below the appliance to the horizontal panel described in c).
c) For all appliances, a panel of sufficient depth to exceed the corresponding dimension of the appliance
by at least 50 mm and of sufficient width to reach the vertical side panels (including the additional panel
described in a) if fitted) is placed horizontally above the appliance at the minimum distance (see X2 in
Figure 12) indicated in the instructions.
d) The back panel is 1,8 m high or of such a height that it extends at least up to the horizontal panel
described in c) and its width is such that it extends at least to the additional side panel described in a).
e) Insulating material: however, if the instructions specify that as an alternative to the specified gaps,
insulating material may be used with the appliance installed with a reduced gap, the test shall be
repeated under these particular conditions.
The floor or the support shall be slightly raised in order to allow natural circulation of air under the panel.
a) For all appliances, the back wall of the building-in unit may be replaced by a panel which shall be at least
as wide as the unit wall and shall be high enough to reach the horizontal panel described in b), or, if the
panel is not required, to reach the top of the building-in unit, but, in all cases, has a height of not less than
1,80 m.
81
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
b) For all appliances with a hotplate, a horizontal panel is placed above the appliance at the minimum
distance indicated in the technical instructions. The panel shall be of a depth sufficient to extend from the
back panel described in a) to at least 50 mm beyond the front of the building-in unit and shall be of a width
sufficient to extend from the additional side panel described in c) to at least 50 mm beyond the opposite
side of the building-in unit.
c) For all appliances with a hotplate, an additional panel is placed vertically at the side of the appliance,
which produces the greatest heating effect at the minimum distance indicated in the technical instructions.
This panel shall be of a depth sufficient to extend from the back panel described in a) to at least 50 mm
beyond the front of the building-in unit and of a height sufficient to extend from the work top to the top of
the back panel described in a).
In order to ensure that the greater heating effect has been determined with respect to the surfaces
mentioned in 6.1.5, it may be necessary to repeat the test with the above mentioned panel on the other
side of the appliance.
d) Appliances intended to stand on the floor shall be placed on a test floor. This shall be of depth
sufficient to extend from the back panel to at least 50 mm beyond the front of the unit and of a width
sufficient to extend at least 50 mm beyond the corresponding dimensions of the building-in unit. The floor
shall be slightly raised to allow natural circulation of air under the panel.
e) For built-in hotplates, if specified in the instructions, an additional horizontal panel made of 15 mm thick
timber is placed below the appliance at the minimum distance from the work top recommended by the
technical instructions.
This panel shall correspond to the critical dimensions which shall be stated in the technical instructions.
If the instructions do not require this horizontal panel to be installed, test no. 1a in 7.3.1.5.2.3 is carried
out with and without this panel.
f) For built-in hotplates, thermocouples are fitted into the work top as described in 7.3.1.5.1.1.
7.3.1.5.2.1 General
The appliance is supplied according to its category with the reference gas indicated in 7.1.1.1 giving the
highest heat input at normal test pressure.
The tests are started from cold and, unless otherwise stated in 7.3.1.5.2.3, the measurements are carried out
in accordance with 7.3.1.5.3 under the following conditions.
Pans are placed simultaneously on the burners, and on the electric cooking plates, if they exist, in accordance
with 7.1.4.2.
At the start of the test, the burners and any electric cooking plates are put into operation, their control being at
their highest setting. As soon as the water boils, the controls are adjusted so that they maintain light boiling
(simmering) and the controls left at this setting until the end of the test.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
82
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
During the test, the pan is covered by its lid and hot water is added to ensure a sufficient water level in order
that boiling can be maintained.
When a burner can operate covered or uncovered, the test is carried out using the arrangement
corresponding to the highest thermal output.
Hotplate griddles
Gas or electric hotplate griddles are put into operation 30 min after the start of the test.
Griddles provided with means of reducing the power are put into operation with the control mechanism set so
as to limit the temperature at the centre of the griddle plate to a value as close as possible to 275 °C but no
lower than 245 °C, unless this condition cannot be obtained, in which case the control mechanism is set to its
highest position.
If a burner can operate either under a pan or under a griddle, the test is carried out using the arrangement
giving the highest thermal input.
Ovens
At the start of the test, gas or electric ovens are put in operation without accessories, the thermostat, or the
control knob if there is no thermostat, being set to the position permitting the maintenance of an average
temperature at the centre of the oven of (200 ± 4) °C, or to the position corresponding to the nearest possible
temperature above 200 °C.
If an appliance has two ovens, they are put in operation simultaneously with their control handles being placed
in the positions permitting the maintenance of an average temperature of (200 ± 4) °C at the centre of each
oven, or the positions corresponding to the nearest possible temperature above 200 °C.
Grills
Grills are operated when this is specified in the tests given in 7.3.1.5.2.3.
The grill is put into operation 30 min after the start of the test with its control mechanism set to the highest
position. After 15 min of operation, the control mechanism is adjusted to obtain half the nominal heat input or
half the nominal electric power.
If the design of the control mechanism is such that it is not possible to reduce the full input or the electric
power by half, but only to a value greater than half, then the control mechanism is adjusted to give the lowest
input or electric power obtainable.
However, if the oven has a rotating spit, the duration of operation of the grill is 60 min with the control
mechanism set to give the most unfavorable conditions specified in the instructions for use and maintenance.
Gas or electric warming drawers and cupboards are put into operation for 30 min after the starting of the test
with their control mechanisms set to the highest position.
Test no. 1a
The appliance is installed under the condition of 7.3.1.5.1 with the following exceptions:
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
83
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
in the case of class 1 appliances, the side test panels are removed;
in the case of class 2, subclass 1 appliances, the side test panels are removed unless the instructions
state that the appliance cannot be used freestanding.
The appliance is operated in accordance with 7.3.1.5.2.2 with the exception that the grill(s) is (are) not
operated.
Test no. 1b
The appliance is installed under the condition of 7.3.1.5.1 with the following exceptions:
in the case of class 1 appliances, the side test panels are removed;
in the case of class 2, subclass 1 appliances, the side test panels are removed unless the instructions
state that the appliance cannot be used freestanding.
the instructions for use and maintenance state that the grill, gas or electric, can be used with the oven
door closed.
Such a grill is operated as described in 7.3.1.5.2.2, simultaneously with the oven if this is possible. If
simultaneous operation is not possible, the test is repeated with the grill operating instead of the oven as
described in 7.3.1.5.2.2.
Test no. 2
The appliance is operated in accordance with 7.3.1.5.2.2 with the following exceptions:
the control of the hotplate cooking elements remain in the fully open position throughout the test, a pan, in
accordance with 7.1.4.1, being placed on each of the burners;
the griddle operates with the control in maximum position throughout the test;
the grill operates throughout the test with the tap in maximum position. Each compartment door is open or
closed, according to the instructions for use and maintenance, and each grid in the highest possible
position under the grill. A plate made of insulating material covers the surface of the grid;
Test no. 3
The appliance is operated in accordance with 7.3.1.5.2.2 with the following exceptions:
each oven is ignited at the start of the test and operates in accordance with 7.1.5;
84
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
if a grill can operate simultaneously with the oven, it is operated for the last 15 min of the test, with its
control in the maximum position and with its grill door open or closed in accordance with the instructions
for use and maintenance;
the grill pan is placed in the normal position indicated in the instructions for use and maintenance as soon
as the grill is operated.
Test no. 4
A test is carried out under the following conditions, with only the parts of the appliance mentioned in operation.
The oven(s) are operated in the cleaning position for 1 h, or according to the instructions for use and
maintenance if these exceed 1 h.
During the last hour, the hotplate elements (gas or electric) are operated as described in 7.3.1.5.2.2 unless
the instructions for use and maintenance forbid their use during the cleaning period.
If, under these conditions of test, the temperature at the centre of the oven is likely to exceed 350 °C the
temperature at the centre of the oven is monitored during the test and after the burners have been turned off.
If, at any time the temperature of the oven exceeds 350 °C then it shall be verified that the requirements of
5.2.1.9.5 are met and that the means provided prevents access to the interior of the oven while the
temperature at the centre of the oven exceeds 350 °C.
Test no. 5
Only the ovens are operated for 1 h at the maximum control setting.
If an electrical grill is situated in an oven and can be operated simultaneously with a gas burner in the same
oven, the test is carried out without the grill in operation and then repeated under the following conditions:
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
if the appliance has a control with a specific setting enabling the oven burner and electrical grill to operate
simultaneously, these are put into operation utilizing the setting enabling the grill to operate for the
longest duration with its maximum setting, any separate oven thermostat being set to its maximum
setting;
if the appliance has separate controls for the oven burner and the electrical grill, the oven and the grill are
put into operation at their maximum control settings.
If, under these conditions of test, the temperature at the centre of the oven is likely to exceed 350 °C the
temperature at the centre of the oven is monitored during the test and after the burners have been turned off.
If, at any time the temperature of the oven exceeds 350 °C then it shall be verified that the requirements of
5.2.1.9.5 are met and that the means provided prevents access to the interior of the oven while the
temperature at the centre of the oven exceeds 350 °C.
Test no. 6
The appliance is installed without side panels, and operates under the conditions of test no. 3 in 7.3.1.5.2.3.
7.3.1.5.3 Measurements
7.3.1.5.3.1 General
During the heating tests, the ambient temperature in the room shall be between 20 °C and 25 °C.
The ambient temperature is measured with an appropriate instrument under the following conditions:
85
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
At the end of each test, it is checked that the appropriate requirements of 6.1.5 are satisfied.
Temperatures are measured by means of an appropriate probe, such as that specified in Annex D.
The probe is applied to the surface with a force of (4 ± 1) N so as to ensure the best possible contact between
the probe and the surface.
The probe is applied for a sufficient period of time for the temperature of the sensing element to be stabilized.
Any measuring instrument giving the same results as the probe shown in D.1 may be used.
Special care is required when the surfaces in question are not flat.
7.3.1.5.3.3 Other parts of the appliance, support and adjacent panels and housing
unit
Suitable thermocouples are used with thermoelectric junctions which are accurate to within ± 2 K.
In order to measure the temperature of the "push-on" connector, thermocouples are inserted between the
cylindrical part of the "push-on" connector and the flexible tube.
However, if the auxiliary equipment is itself likely to cause a rise in temperature (e.g. electromagnetic valves),
the temperature of auxiliary equipment is not measured. In this case, thermocouples are placed so as to
measure the air temperature close to the device.
The temperature measurements of the auxiliary equipment are deemed to be satisfactory if:
tm ≤ tmax + ta – 25 (11)
where
In order to produce conditions more severe than in practice, the tests described in 6.1.6 are carried out as
follows:
the oven burner and those of the hotplate are supplied with G30 gas by a cylinder outside the appliance;
the controls for the hotplate burners and the electric cooking plates are in the full-on position, pans being
placed according to 7.1.4.2; it is allowed to add water to the pans during the test, in order that boiling can
continue for the time necessary for the test;
86 --`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
if a grill can operate simultaneously with the oven, it is supplied under the same conditions and put into
operation during the last 15 min of oven operation, its control being in the maximum position;
the cylinder placed in the appliance compartment is the largest of those recommended in the instructions
4
for use and maintenance; it is filled to /5 of its volumetric water capacity with gas G30 and supplies an
external burner, not part of the appliance, at a heat input equal to the nominal heat input of the gas oven.
If the appliance does not have a gas oven, the incorporated cylinder is not turned on during this test;
the temperatures of the push-on connector and of the walls of the compartment are checked with
thermocouples. The increase of pressure is measured with a manometer as shown diagrammatically in
Figure 6.
For this test, account is taken of the existence of any means of guiding the flexible tube, of the appropriate
instructions and of the warning notice, written in a legible and durable fashion, fixed inside the compartment
on a non-removable part.
The measurement is carried out, after 1 h of operation and during the first 30 min which follow complete
extinction.
However, in the case of an electric pyrolytic oven, the oven is put into operation at its cleaning setting for the
maximum period specified by the manufacturer. During the last hour of oven operation the hotplate elements
which can operate are operated with the burners supplied at half rate.
In the case of an electric oven or grill, the test is repeated without the hotplate burners in operation.
Each burner is supplied with reference gas (see 7.1.1.1) at normal test pressure (see 7.1.2) and with the
corresponding injector. If the appliance category includes several reference gases, the test is carried out only
with the one having the lowest Wobbe index.
Each burner having been adjusted individually to give, with reference gas and at normal test pressure, the
nominal heat input given by the manufacturer, this gas is replaced by air under the same conditions. The air
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
rate is measured for each burner in turn, and then the total rate is measured with all the taps open
simultaneously. If there is a flame supervision device, it shall be arranged so that air reaches the injectors (e.g.
by separate heating of the sensing element).
It is verified that the requirements of 6.1.7 are satisfied by the air rates measured.
For these tests, measurements are taken when the burner(s) are at thermal equilibrium.
With the appliance initially at ambient temperature, two tests are carried out using the reference gas(es). Each
test begins with adjusting the gas rate in the following way at normal supply pressure using the appliance
tap(s).
Test no. 1
2
For an appliance with several burners, the gas rate corresponds to /3 of the sum of the nominal heat inputs of
all the burners which can function simultaneously. For an appliance with only one burner, the gas rate
corresponds to the nominal heat input.
87
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Test no. 2
3 3
The appliance gas rate is adjusted to 0,08 m /h for first family gases and to 0,05 m /h for second family gases,
3
and to 0,02 m /h for third family gases.
For each test, the appliance inlet pressure is varied between the minimum and maximum values in Table 9
and it is checked that the requirements of 6.1.8 are satisfied.
7.3.2.1.1 General
Each burner is adjusted under the conditions described in 7.1.3.2 with each reference gas belonging to the
appliance category.
The burner is lit in accordance with the instructions for use by means of the ignition system, is there is one, or
with a match if the burner does not have an ignition system.
When the ignition system only delivers one spark at a time, for the purposes of the test it is operated at most
three times at intervals of about 1 s. The first ignition attempt is made when the gas arrives at the burner ports.
In order to know the time of arrival of the gas at the burner ports, an auxiliary ignition flame is placed near to
the burner ports. The time which elapses between the moment when the tap is placed in the full-on position
and the moment when the burner ignites is measured.
Where the use of a pan is required on a burner in the following tests, a pan in accordance with 7.1.4 is used,
preferably one made of glass so that the flame can be observed.
In the case of temporary griddles and temporary covered burners, the burner is tested firstly with the plate or
griddle in place, then as an uncovered burner.
Where uncovered burners do not have an ignition system and covered burners are tested individually, the
tests are carried out without a pan. The tests in which they operate simultaneously with other burners of the
hotplate are carried out with the pans recommended in 7.1.4.2.
In the case of uncovered burners with an ignition system, the requirements regarding the use of pans are
specified for each test.
In all cases, hotplate burners are tested successively in the following order: back right burner, back left burner,
front left burner, front right burner, where the hotplate has four burners. If the hotplate has a different number
of burners, the order of ignition is based on the order given for four burners.
In tests requiring the operation of ovens and grills placed beneath the hotplate, all these ovens and grills
operate simultaneously if this is possible.
If simultaneous operation is not possible because there is an oven and grill in the same compartment, the
tests are carried out once with the oven in operation and once with the grill in operation. If there is a second
oven or grill beneath the hotplate, it operates in both cases.
The requirements for ignition, cross-ignition and flame stability in 6.2.1 are verified during the following tests.
However, for independent hotplates, the tests in 7.3.2.1.2 second group, requiring the use of reference gases
and those in 7.3.2.1.3 first group, do not apply.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
88
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
With the appliance at ambient temperature, the correct ignition and flame stability of each of the hotplate
burners is checked with them operating individually.
Two groups of tests are carried out under the following conditions.
Uncovered burners which have an ignition system are tested with and without a pan.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Correct ignition and cross-lighting of each burner are checked individually with the appliance supplied
successively with each of the reference gases at the normal test pressure.
After 5 s operation, the tap is turned to the reduced rate position at normal speed12) and it is verified that the
burner is not extinguished.
The tap is turned to the maximum flow position and flame stability is verified.
Any ovens and/or grills situated under the hotplate, whether gas or electric, are put into operation for 3 min
and continue to operate throughout the test.
Uncovered burners which have an ignition system are tested with and without a pan.
With the appliance supplied successively with each of the reference gases under normal test pressure, correct
ignition and cross-lighting of each of the burners, tested individually, are verified between the end of the third
and the end of the fifth minute after ignition of the oven and/or the grill.
Once each burner has been tested, the tap is returned to the closed position. At the end of the test, the
appliance is cooled.
2. With the appliance cold at the start of the test, any ovens and/or grills are operated for 3 min and
continue to operate throughout the test.
With the appliance supplied with the limit flame lift gas(es) of the category to which the appliance belongs
under maximum test pressure, the ignition, cross-lighting and flame stability of each of the burners, tested
individually, are verified between the end of the third minute and the end of the eighth minute after ignition of
the ovens and/or grill.
Following examination of the flames of each burner, the tap is returned to the closed position. At the end of
the test, the appliance is cooled.
89
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Correct ignition of the burner and flame stability are verified for each hotplate burner tested individually.
Any ovens and/or grill placed beneath the hotplate, whether gas or electric, are operated in accordance with
7.1.5.
Ovens operate initially for 30 min, the grill, if it can operate alone, for 15 min. Where a separate oven and grill
can operate simultaneously, the grill is put in operation 15 min after the oven.
Three groups of tests are carried out under the conditions described below.
If it is necessary during the execution of one group of tests to cool the appliance, for example in order to
change gas, the initial conditions fixed for the corresponding group of tests shall be re-established before any
further test is carried out.
The tests are carried out without a test pan on the burner.
1. With the appliance supplied successively with each of the reference gases under normal pressure,
correct ignition and cross-lighting of each burner, tested individually in the order stated in 7.3.2.1.1, are
verified.
2. With the appliance supplied with the flame lift gas(es) of the category to which the appliance belongs
under maximum pressure, ignition, cross-lighting and flame stability are verified for each burner when
tested individually.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Following examination of the flame of each burner, the tap is returned to the closed position.
For the purposes of the test, the second test group is carried out immediately after the first group, with the
ovens still in operation.
However, if the first test group includes the operation of a grill, the appliance is allowed to cool down then is
put into operation again under the conditions stated for the first test group.
A pan is placed centrally on each of the burners and the electric cooking plates, according to 7.1.4.2.
All the hotplate burners or electric cooking plates are operated initially at reduced rate for 10 min then each
burner is successively:
extinguished;
If there is an ignition system, the pan is not removed. If ignition is carried out with a match, the pan is removed
in order to light the burner and then replaced.
1. with the appliance supplied successively with each of the reference gases under normal test pressure,
the correct ignition and cross-lighting of each burner, tested individually, are verified.
90
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
2. with the appliance supplied with the flame lift limit gas(es) of the category to which the appliance
belongs under maximum test pressure, ignition, cross-lighting and flame stability are verified for each
burner when tested individually.
Following examination of the flame, the tap is turned from the full-on position to the reduced rate
position at normal speed13). In the course of this operation, extinction shall not occur.
3. with the hotplate burner taps adjusted to the reduced rate position, it is then verified that, with the
reference gas under normal test pressure, no extinction or light-back is observed:
during opening or closing at normal speed15) of the door of the housing unit or each of the doors of
the housing unit in succession, if there are several.
For the purposes of the tests, the third test group is carried out immediately after the second group, with the
ovens and electric cooking plates still in operation.
However, if the second test group includes the operation of a grill, the appliance is allowed to cool down, then
is put into operation again under the conditions stated for the second test group.
A pan is placed centrally on each of the burners and the electric cooking plates in accordance with 7.1.4.2.
Each hotplate burner is supplied with the light back limit gas(es) under minimum test pressure. On turning the
tap at normal speed16) from the full-on position to the reduced rate position, it is checked that no light back or
extinction occur.
This test is carried out using each of the reference gases supplied at the corresponding maximum and
minimum pressures. Each test is carried out without a pan over the burner.
Any multi-ring hotplate burner with sectional control is tested individually. With the appliance cold, reduce the
gas rate supplied to the supervised ring of burner ports until it corresponds to that obtained when the tap or
control is set to its lowest marked position. Turn the burner control17) in accordance with the manufacturer's
instructions to open the gas supply to the other ring(s) of burner ports and verify that ignition and cross-lighting
at any unsupervised ring of burner ports from the supervised ring of burner ports occurs smoothly within 5 s.
Any multi-ring hotplate burner with simple control is tested individually. With the appliance cold, ignite the
burner with its tap or control set to the lowest marked position for which ignition of the supervised ring of
burner ports is possible. Verify that ignition and cross-lighting at any unsupervised ring of burner ports occurs
smoothly within 5 s.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
91
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
For the resistance to draught test, the upper side panels mounted above the level of the hotplate are not
installed.
Each uncovered multi-ring hotplate burner equipped with a single flame supervision device is operated
successively according to the conditions of 7.1.3.2 for each reference gas of the category to which it belongs.
The test is carried out with the burner hot. For this purpose, a pan, in accordance with 7.1.4.1, is placed on the
burner which is operated at its nominal heat input for 10 min. The reference gas is then replaced by the flame
lift limit gas.
The pan is removed and the test device shown in Figure 7 is so placed that the blade of the pendulum is
centred over the burner, the distance between the lower edge of the pendulum and the plane of the pan
supports being 25 mm. The pendulum is set in an initial position 30° to the vertical, its plane of oscillation
being parallel to the front of the appliance. The pendulum is allowed to swing in one direction and then,
separated by an interval of at least 10 s, it is allowed to swing in the other direction. The appliance is then
tested successively with the flame lift limit gas or gases corresponding to each reference gas of the category
to which it belongs and at the normal test pressure corresponding to these limit gases (see 7.1.1.1 and 7.1.2).
Complete extinction of the burner is tolerated if the gas supply to the burner is shut off under the control of its
flame supervision device. Partial extinction is tolerated provided that re-ignition and cross-lighting occurs
spontaneously within 5 s.
This test is carried out for each uncovered multi-ring hotplate burner that is equipped with a single flame
supervision device.
The burners, operating individually at their nominal heat input and supplied only with the reference gases
under the conditions specified in 7.1.3.2, are used to bring to the boil and maintain at boiling point a clean
160 mm diameter (see C.1) pan, without a lid, filled with water to 10 mm below the rim; this diameter is
increased to 220 mm for burners of nominal heat input equal to or greater than 3,5 kW.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The test is continued until there is no more spillage.
Complete extinction of the burner is tolerated if the gas supply to the burner is shut off under the control of its
flame supervision device. Partial extinction is tolerated provided that re-ignition and cross-lighting occurs
spontaneously within 5 s. After this test, spilled liquid shall be removed and the burner shall be capable of
being re-lit easily.
7.3.2.4 Combustion
The appliance shall be installed according to the conditions defined in 7.1.3.3, each of the burners having
previously been adjusted to its nominal heat input according to the conditions specified in 7.1.3.2.
The requirements of 6.2.2 are verified in the course of the tests given in Table 11.
92
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Tests no. 1, 2, 3, 4 and 6 are carried out with and without the special removable supports for small pans on
the burners for which the instructions for use and maintenance specify their use.
Test no. 5 is only carried out when the appliance has a mains electricity supply. Any special support for small
pans is not used.
For appliances that have no gas rate adjuster or regulator, or for appliances fitted with these devices where
their function has been annulled, the test pressure is the maximum pressure indicated in 7.1.2, corrected in
accordance with 7.1.3.2.4, for the test gases used (see 7.1.1.1) as appropriate to the appliance category.
For appliances with gas rate adjusters but without regulators, the test is carried out by adjusting the burner to
give a rate equal to 1,10 times the nominal heat input.
For governed appliances, the test is carried out with the burner heat input raised to a value of 1,075 times the
nominal heat input.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
This test is carried out immediately after test no. 1 without cooling down the appliance.
The heat input of the burner is adjusted to half the nominal heat input using the burner tap.
For griddles, this test is carried out using the position corresponding to half the nominal heat input, or, if this is
not possible, using the position corresponding to the heat input which is as close to this as can be obtained.
93
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The incomplete combustion limit gas(es) is used without changing the adjustments and pressures used for the
corresponding reference gas used in test no. 1.
The test is carried out with each of the reference gases, supplied at the normal test pressure, under the
following conditions of simultaneous operation:
b) ovens are operated with their controls in the position corresponding to the maximum cooking
temperature;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
c) with the exception of a high level grill, which is not operated during this test, grills situated in separate
compartments are operated with their controls in the position corresponding to half the nominal heat input
(electric power), or, if this is not possible, using the position corresponding to a heat input (electric power)
as close to this as possible;
d) in the case of a grill situated in the same compartment as an oven, the test is repeated with the grill
operating, as described in c), instead of the oven. All other elements of the appliance, including any other
oven, are operated under the conditions mentioned in b).
If fluctuations of the main electrical voltage can have an influence on the operation, ignition and/or combustion
the test is carried out individually on each burner with one of the reference gases (see Table 11) at the normal
test pressure, the appliance being supplied with electricity at 1,10 times the maximum nominal voltage
specified on the appliance.
The test is repeated with the appliance supplied with electricity at 0,85 times the minimum nominal voltage.
This test is only applicable to multi-ring hotplate burners with sectional control by means of a single gas tap or
control. The test is carried out with each of the reference gases, supplied at the normal test pressure.
The sampling of combustion products is carried out with each burner in turn.
A pan is placed on the burner in accordance with 7.1.4.1. However, no pan shall be placed on covered
burners if the plate would not be entirely covered by the pan.
When a round pan of 220 mm diameter is used it is covered with a sampling device as shown in Figure 9.
When a round pan of 300 mm is used it is covered with a sampling device as shown in Figure 8. In the other
cases, the sampling device is a 500 mm × 300 mm hood as shown in Figure 10, placed at a distance of
between 20 mm and 80 mm above the level18) of the pan supports or of the griddle plate.
The combustion products are sampled by drawing off some of these gases in the upper part of the sampling
device. The requirement shall be verified 20 min after the start of the test.
18) If the CO concentration is greater than 2 %, it shall be checked that the quality of combustion is not affected by the
2
sampling method.
94
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
A restrictor may be used to obtain this CO2 concentration. If it is impossible to obtain a CO2 concentration of
1 % by volume without compromising the result, a value of less than 1 % is acceptable but the laboratory shall
ensure that the sample taken is representative.
Each of the hotplate burners and electric cooking plates is covered with a pan in accordance with 7.1.4.2.
However, no pan is placed on covered burners if the plate would not be entirely covered by the pan.
Accessories for the oven or grill situated under the hotplate are put in the normal position for use.
The combustion products are sampled 20 min after the start of the test.
A sampling device is placed over the appliance such as those shown as examples in Figure 10, selected
according to the shape of the hotplate. The device shall overlap the hotplate by at least 40 mm. If the
appliance has a shut-down lid or a high level grill which renders this arrangement impossible, the device is slid
between the lid and the back panel of the test installation. It shall overlap the other three sides of the hotplate
by at least 40 mm.
This device shall collect all the products of combustion (including those from any oven or grill in operation) but
shall not alter their course to the extent where this is likely to affect the quality of combustion. In particular, the
distance between the base of the device and the level of the pan supports shall be such that it does not affect
the quality of combustion of the burners, there is no escape of products of combustion from the base of the
sampling device and that the CO2 concentration in greater than 1 % by volume. This distance shall be
between 20 mm and 80 mm.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
If the CO2 concentration in the combustion products is less than 1 % by volume, a restrictor is placed in the
upper part of this device in order to bring this quantity to a value slightly over 1 %. However, this restrictor is
not used if it affects combustion quality or if, as a result of its presence, the combustion products spill outside
the device, but the laboratory shall then ensure that the sample is representative.
The volumetric concentration of CO in the air and water vapor free products (neutral combustion) is given by
the following equation:
(CO 2 )N
(CO)N = (CO)M ·
(CO 2 )M (12)
where
(CO)N is the volumetric percentage of carbon monoxide content relative to the dry, air-
free products of combustion;
(CO2)N is the volumetric percentage of carbon dioxide calculated for the dry, air-free
products of combustion;
(CO)M and (CO2)M are the volumetric percentages of carbon monoxide and carbon dioxide
measured in the dry sample during the combustion test.
The % values of (CO2)N for the test gases are given in Table 12.
95
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Designation of gas G110 G120 G130 G150 G20 G21 G25 G26 G30 G31
% (C02)N 7,6 8,35 13,7 11,8 11,7 12,2 11,5 11,9 14,0 13,7
(neutral
combustion)
For all the tests, the CO is measured using a selective method allowing the detection with certainty of a
concentration of 0,005 % by volume and measurement with a relative error not exceeding 6 %.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
NOTE The use of infra-red absorption analysers is recommended.
At the end of test no. 3 of 7.3.2.4.1, the sooting limit gas(es) is(are) substituted for the incomplete combustion
gas(es) and the pressure is adjusted to the normal test pressure value corresponding to the category of
appliance.
The pan covering the burner is replaced by an identical clean pan and the requirements of 6.2.2, paragraph 3,
are verified after 10 min operation.
7.3.3.1.1 General
The appliance is installed according to the conditions in 7.1.3.3 in a suitably ventilated room.
Each burner is adjusted in accordance with the conditions of 7.1.3.2 with each reference gas of the appliance
category.
the oven doors are closed if ignition can be carried out under these conditions;
the grill door is closed if allowed by the instructions for use and maintenance;
the tests are carried out without oven and grill accessories.
The burner is lit by means of the ignition system, if there is one. When the burner does not have an ignition
system, it is lit by a match.
When the ignition system only delivers one spark at a time, for the purposes of the test it is operated at most
three times at intervals of about 1 s. The first ignition attempt is made when the gas arrives at the burner ports.
In order to determine the time of arrival of the gas at the burner ports, an auxiliary ignition flame is placed near
to the burner ports. The time which elapses between the moment when the tap is moved to the full-on position
and the moment when the burner ignites is measured.
The requirements of 6.3.1 are verified in the course of the following tests.
96
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
With the appliance at ambient temperature, correct ignition and flame stability of each oven or grill burner,
when operating individually, are checked under the following conditions:
the tap is placed in the ignition position indicated in the instructions for use and maintenance.
The requirements of 6.3.1 concerning ignition and cross-lighting shall be verified with:
the flame lift limit gas or gases for the appliance category under maximum test pressure;
the incomplete combustion limit gas or gases for the appliance category at the normal test pressure.
With the appliance at ambient temperature, the oven or grill are operated separately for 10 min with the
control device in the maximum position and the door closed if the instructions for use and maintenance do not
forbid this. Return the control to the closed position. After 1 min, place the control in the ignition position
indicated in the instructions for use and maintenance and light the burner.
the flame lift limit gas(es) for the appliance category under maximum test pressure;
the light back limit gas(es) for the appliance category at minimum test pressure;
the incomplete combustion limit gas(es) for the appliance category at the normal test pressure.
After previously operating the oven or grill for 10 min under the conditions of 7.3.3.1.3 with the following
gases:
the flame lift limit gas(es) for the appliance category at minimum test pressure;
the light back limit gas(es) for the appliance category at minimum test pressure.
The control handle is turned at normal speed19) towards the minimum position, if there is one.
If the appliance has two ovens or grills, gas or electric, which can operate simultaneously and affect each
other, the burners are adjusted successively, if this is possible, to their reduced rate position after 10 min of
simultaneous operation, the setting for the other oven or grill, gas or electric, remaining in the maximum
position.
97
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The resistance of the oven burner flames to movements of the oven door is verified as follows under the same
gas supply conditions as in 7.3.3.1.4.
With the oven door open and the pilot, if any, lit, light the oven burner, with the oven tap in the ignition position
indicated in the instructions for use and maintenance. Close the oven door and check that the oven burner
and pilot remain alight.
After 30 min of operation in accordance with 7.1.5, the control is turned at normal speed20) to the minimum
position:
after 15 s approximately, open the oven door and observe the flames;
close the door and approximately 15 s later, turn the control to its maximum position at normal speed21);
after 15 s approximately, open the door and check that the burner and any pilot, if any, are operating
normally.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The movement of the door is carried out at normal speed22).
If the appliance has ovens or grills which can operate simultaneously and which can have an effect on one
another, they are also tested during simultaneous operation. The effect of opening the door of the oven or
ovens is examined after the ovens and/or grills have been operated as described in 7.3.2.1.2.
Class 3 ovens are installed in a tall building-in unit having one or several doors in accordance with 7.1.3.3.3.2 b).
After pre-heating the oven for 30 min and turning down the control under the conditions of 7.3.3.1.5, the
cupboard door(s) are opened to 90° and then closed successively at normal speed23).
after operating the oven for 30 min under the conditions of 7.1.5, it is turned off;
a grill burner ignition test is carried out immediately using reference gas.
If a grill is so situated that it can be affected by the operation of the hotplate burners and/or oven burners, the
following test shall be carried out:
ignite the hotplate burners with their taps set in the full on position, using each of the reference gases at
normal test pressure;
22) 23) Complete opening and closure, at fairly constant speed, in a time of about 1 s.
98
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
as soon as the water boils, adjust the burner tap so that the water is just kept boiling;
light the oven burners at the same time as the hotplate burners and operate in accordance with 7.1.5;
put the grill pan in its normal position and 30 min after the start of the test, check that the grill ignition is
satisfactory. Repeat the ignition without the grill accessories;
during these tests, observe the grill flame stability with and without the accessories;
the tests are repeated with the flame lift limit gas(es) at maximum test pressure.
If two ovens or grills can operate simultaneously and if the operation of one can affect the ignition, cross-
lighting or flame stability of the other, the following test is carried out with one of the reference gases at normal
test pressure under the following conditions:
if it is an oven that is likely to affect another oven or grill, it is first operated for 30 min in accordance with
7.1.5;
if it is a grill that is likely to affect another oven or grill, it is first operated for 15 min at full rate.
If an appliance has an oven, the following test is carried out except in the case of a class 1 appliance which, in
accordance with the technical instructions, can only be installed with one side adjacent to a wall or to another
unit.
For this test, the appliance is installed under the conditions defined in 7.1.3.3 with the following exceptions:
the building-in unit for a class 3 appliance is provided with the ventilation specified by the manufacturer in
the technical instructions (see 8.3.2.4). The ventilation located below the oven burner shall have the
minimum cross-section stated in the instructions ; ventilation located above the oven burner shall have
the largest permitted cross-section;
if, according to the technical instructions, a class 3 appliance is capable of being installed under the
hotplate and in a tall kitchen unit, the test is carried out in the tall unit only.
The test is carried out with the appliance supplied with one of the reference gases under normal test pressure.
The oven is ignited then operates with the door closed for 30 min with the oven control in the position
corresponding to the specifications of 7.1.5. The control is then moved to its maximum position and returned
in stages to its minimum position, ensuring the flames are observed at all the intermediate heights. If
disturbance in the flames is observed, the control is then held in position, so as to check, if under these
conditions, the appliance is damaged or if safety of operation is affected.
With the control having been in its minimum position for 15 s, the door is opened and the control is returned in
stages to its maximum position, ensuring that the flames are observed at all their intermediate heights. If
disturbance in the flames is observed, the control is then held in position, so as to check whether, under these
conditions, the appliance is damaged or if safety of operation is affected.
7.3.3.2 Combustion
Compliance with the requirements of 6.3.2 is checked under the following conditions.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
99
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
7.3.3.2.2 General
The oven and grill burners are supplied successively and initially adjusted under the conditions given in
7.1.3.2. Any adjusters are immobilized in the previously determined positions.
the thermostat or tap of the oven or grill is set in the position giving the highest temperature;
NOTE In the case where the shut-down lid in its closed position can disturb the path of the products of combustion
from any oven or grill which can operate in these circumstances, the tests are repeated with the shut-down lid closed.
the grill door is open or closed according to the instructions for use and maintenance;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
the oven or grill accessory supplied by the manufacturer that has the greatest area opposing the
circulation of the products of combustion is placed as close as possible to the middle of the oven;
the sampling of the products of combustion is carried out in such a way that the sample taken is
representative, i.e. as close as possible to the average composition of all the products of combustion. The
CO2 content shall be greater than 1 % by volume.
For example, for a high level grill, a hood similar to that described in Figure 11 can be used. In all cases, the
hood is placed at a distance of not less than 25 mm above the grill. This device shall collect all products of
combustion but shall not affect their course especially in the zone likely to have an effect on combustion
quality.
Unless instructed to the contrary, tests are carried out with each reference gas, then with the incomplete
combustion limit gas(es) specified in 7.1.1.1 according to the appliance category.
For burners that have no gas rate adjuster or pressure regulator, or for appliances fitted with these devices
where their function has been annulled, the test pressure is the maximum pressure specified in 7.1.2,
corrected as indicated in 7.1.3.2.4, for the test gases used (see 7.1.1.1), corresponding to the appliance
category.
For burners with gas rate adjuster but without pressure regulator, the test is carried out by adjusting the burner
to an input 1,10 times the nominal heat input with the reference gas.
For regulated appliances, the test is carried out with the burner heat input raised to value 1,075 times the
nominal heat input with the reference gas.
If fluctuation of the mains electrical voltage can influence the operation, ignition and/or combustion, the test is
carried out with each oven and grill burner operating individually with one of the reference gases (that giving
the highest CO concentration during the test carried out in accordance with 7.3.3.2.2), at the normal test
pressure, the appliance being supplied at 1,10 times the nominal maximum voltage specified on the appliance.
100
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The test is repeated with the appliance supplied at 0,85 times the nominal minimum voltage specified on the
appliance.
Ovens and grills located below a hotplate, when operating with each of the reference gases at the normal test
pressure under the following conditions, shall meet the requirements of 5.2.9.3.
The thermostat is set in at the maximum position or, if there is no thermostat, the tap is set in the full-on
position.
Two 220 mm diameter pans are placed flat on the pan support of the hotplate. They are then moved as far off-
centre from their respective burners as possible in order, whilst retaining their stability on the pan supports, to
cause the maximum obstruction to the flow of combustion products from the oven or grill.
A test is carried out using each of the reference gases for the range of heat inputs between 100 % and 50 %
of the nominal heat input or the minimum heat input allowed by the controls when this is greater than 50 % of
the nominal heat input.
If the design of the tap only allows the operation of the grill at the nominal heat input, or if it is clear from the
marking and from the instructions given in the manufacturer's instructions for use and maintenance that the
grill shall only be used at its nominal heat input, a test is carried out using each of the reference gases at the
corrected minimum pressure p'min in accordance with 7.1.3.2.4.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The combustion of high-level grills, if they can be affected by the operation of the oven or hotplate burners,
shall meet the requirements of 6.3.2 when the appliance is operated with each reference gas under the
conditions of 7.3.3.1.8, with the grill accessories in place.
Sampling of the combustion products is carried out with the hood described in Figure 11 after the grill has
been lit and has been operated for 15 min.
7.3.3.2.8 !Grill burner intended to be operated with compartment door open tested with the
compartment door closed
The test is carried out with the appliance supplied according to its category with each reference gas at the
corresponding normal pressure. The test is carried out with the grill burner operated individually.
The test is carried out first without any oven or grill accessories in place.
For a grill in an oven compartment the test is repeated with the oven or grill accessory supplied by the
manufacturer that has the greatest area opposing the circulation of the products of combustion in place as
close as possible to the middle of the oven, any detachable handle having been removed.
For a separate grill compartment the test is repeated with its grill accessory in place but only if it is possible to
close the grill compartment door when this accessory, any detachable handle having been removed, is in
place under the grill.
101
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
With the appliance at ambient temperature, the grill burner is ignited with its control in the maximum position
and then the compartment door is immediately closed 24 ).After 15 min, begin sampling the products of
combustion. The test is continued for a further 45 min, or until the maximum CO content of the air- and water
vapour-free products of combustion is achieved, whichever the shorter.
If the grill burner flames have been extinguished before sampling begins open the compartment door and
re-ignite the burner and operate it for 10 min with its control in the maximum position. The compartment door
is then closed 24) and after 15 min begin sampling the products of combustion. The test is continued for a
further 45 min, or until the maximum CO content of the air- and water vapour-free products of combustion is
achieved, whichever the shorter.
For a grill burner with a reduced rate position, the test is repeated with the grill burner control adjusted to its
reduced rate position.
In the case of a fixed rate grill burner, repeat the test at minimum supply pressure."
All specifications referred to in this clause shall be given in the technical instructions.
8.1.1 All appliances shall bear in a way which is visible, legible for the installer and indelible25) at least the
following information on one or more data plates and/or labels fixed securely and durably onto the appliance:
the type of gas and the pressure and/or pressure couple for which the appliance is adjusted; any
reference to pressure shall be identified in relation to the corresponding category index;
the appliance category or categories: if more than one category is specified, each of these categories
shall be identified in relation to the direct country or countries of destination;
the nominal heat input of all the burners, expressed in kilowatts based on the gross calorific value and, for
liquefied petroleum gas, the gas rate in grams per hour.
This information shall be written with the aid of symbols in accordance with Annex E.
No other information shall be given on the appliance if it is likely to cause confusion regarding the current
adjustment setting of the appliance, the corresponding category or categories and the direct country or
countries of destination.
24) !Where the appliance has a factory-fitted means that does not rely on user for its operation to physically prevent
closure of the grill door whilst the grill burner is in operation, the test is performed with the door closed to the position
allowed by this device."
25) The indelibility of the markings is verified by a test carried out in accordance with EN 60335-1.
26) "Manufacturer" is taken to mean the company or organization which assumes responsibility for the product.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
102
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
For example, if it is necessary to adjust the appliance in order to convert it from one pressure to another within a third
family pressure couple, only the pressure corresponding to the actual adjustment shall be indicated.
8.1.2 All appliances shall bear, in a legible manner which is visible to the installer and the user, one or
more warnings, drafted in the official language(s) of the direct country or countries of destination of the
appliance.
"This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated
space. Read the instructions before installing or using this appliance."
In addition, for appliances having a third family gas cylinder compartment, the interior of the compartment door
shall bear a warning, specifying the dimensions of the cylinders to be used in the countries where the
appliance can be sold and, where necessary, the notice shall describe the means of assuring a particular path
for the flexible tube used for connection.
8.1.3 Where the appliance is designed for remote operation of type 2, the hand held remote control
supplied with the appliance shall be marked with:
a serial number which shall also be specified in the manufacturer’s instructions for use and maintenance.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
8.2 Marking of the packaging
the type of gas and the pressure and/or pressure couple for which the appliance is adjusted; any
reference to pressure, shall be identified in relation to the corresponding category index;
NOTE If it is necessary to adjust the appliance in order to convert it from one pressure to another within a third family
pressure couple, only the pressure corresponding to the current adjustment needs to be indicated.
the appliance category or categories: if more than one category is specified, each of these categories
shall be identified in relation to the appropriate direct country or countries of destination.
This information shall be written with aid of symbols in accordance with Annex E.
No other information shall be given on the packaging if it is likely to cause confusion regarding the current
adjustment setting of the appliance, the corresponding category or categories and the direct country or
countries of destination.
In addition, the following warning, drafted in the official language(s) of the country or countries of direct
destination of the appliance, shall be given on the packaging:
"This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated
space. Read the instructions before installing or using this appliance."
103
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
8.3 Instructions
8.3.1 General
The appliance shall be accompanied by technical instructions intended for the installer and by instructions for
use and maintenance intended for the user.
They may be presented together but their texts shall not be confused.
These instructions shall contain information relating to the class of the appliance and also the address of the
manufacturer27) and the respective information given in 8.3.2 and 8.3.3.
They shall be written in the official language or languages of the country or countries of direct destination of
the appliance and shall be valid for this country or countries.
If the instructions are written in an official language that is used by more than one country, the country or
countries for which they are valid shall be identified using the symbols given in Annex E.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Instructions for countries other that those mentioned on the appliance may be supplied with the appliance on
condition that each set of instructions includes the following initial statement: "These instructions are only valid
if the country symbol appears on the appliance. If the symbol does not appear on the appliance, it is
necessary to refer to the technical instructions which will provide the necessary instructions concerning
modification of the appliance to the conditions of use of the country".
8.3.2.1 General
The technical instructions intended for the installer shall give all instructions for installation, adjustment and
maintenance.
In addition to the information given in 8.1, the technical instructions may include information, where
appropriate, that the appliance has been certified for use in countries other than those stated on the appliance.
If such information is given, the instructions shall include a warning stipulating that modification of the
appliance and its method of installation are essential in order to use the appliance safely and correctly in all
the additional countries. This warning shall be repeated in the official language(s) of each of these countries.
Furthermore, the technical instructions shall state how to obtain the information, instructions and parts
necessary for safe and correct use in the country concerned.
a) "prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and
the adjustment of the appliance are compatible";
b) "the adjustment conditions for this appliance are stated on the label (or data plate)";
c) "this appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation".
27) "Manufacturer" is taken to mean the company or organization which assumes responsibility for the product.
104
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
the nominal rates of the different burners, expressed in kilowatts based on the gross calorific value and in
grams per hour for liquefied petroleum gas;
adjustment devices;
For an appliance that is likely to operate with several gases, these instructions shall also state the operations
and adjustments to be carried out when converting from one gas to another. It should give, for each of the
interchangeable injectors and calibrated orifices, the markings for each gas and pressures that may be used.
For appliances intended to operate exclusively with the factory-fitted injector, the instructions shall where
necessary, give information concerning the use of products for making pressure-tight joints on the thread in
the event of the injectors concerned being dismantled.
These instructions shall also give precise indications for connecting the appliance to the gas and a reference
to the installation regulations in force in the country in which the appliance is to be used. In particular, the
technical instructions shall specify the type, length and position of any flexible tubing which may be used for
supplying gas and details for the fitting and use of gas connection adaptors.
If the temperature rise above ambient temperature of a part of the appliance likely to be in contact with the
flexible tube exceeds 70 K, the maximum temperature shall be stated and a label shall be fixed adjacent to the
gas inlet connection stating that an appropriate connecting tube shall be used in accordance with the
corresponding national installation regulations.
If the appliance is connected to an electrical supply, the technical instructions shall include a wiring diagram
(for connection purposes) unless the appliance is equipped with a connection cord fitted with a plug.
a) the minimum vertical distance separating the appliance from adjacent horizontal walls located above it;
b) the minimum horizontal distances separating the appliance from adjacent vertical walls below the
minimum distance defined in a). All horizontal distances are measured from the vertical plane which
coincides with that of the side of the appliance.
For class 1 appliances, with the exception of high-level grills, these stated minimum distances shall not
exceed 20 mm for walls adjacent to the sides which are:
below the shut-down lid in its closed position, for appliances fitted with a shut-down lid and designed so
that the lid is at the same level as the work top of adjacent units, or
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The technical instructions shall also give information concerning the fixing of the appliance, where this is
specified by the manufacturer or required by the installation regulations in force in the country or countries in
which the appliance may be used.
The technical instructions shall give all necessary information for building-in and fixing the appliance, and in
particular:
105
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
a) for all appliances concerned, information giving the critical dimensions of the space in which the appliance
is to be installed;
b) precise instructions that are to be observed for the evacuation of combustion products, and for ventilation
when flueing and ventilation components are not supplied with the appliance, or where they are supplied
but not fitted to the appliance;
c) in the case of an appliance incorporating a hotplate, information on the minimum distances from each
adjacent wall above the level of the hotplate:
1) the minimum vertical distance above the hotplate is measured from the plane of the pan supports;
2) the minimum horizontal distances are measured from the vertical planes passing through the edges
of the hotplate;
d) in the case of built-in hotplates, where the manufacturer specifies that a horizontal separation shall be
included below the base of the hotplate, the critical dimensions of this separation. In addition, the
minimum distance between this separation and the underneath of the worktop shall be stated and this
minimum distance declared shall not exceed 150 mm;
e) in the case of appliances with an oven, information stating that the unit housing the appliance shall be
appropriately fixed.
Also, where the use of a flexible tube is specified, the instructions shall state that the flexible tube shall be
fitted in such a way that it cannot come into contact with a moveable part of the housing unit (e.g. a drawer)
and does not pass through any space susceptible of becoming congested.
The instructions for use and maintenance intended for the user shall give all necessary information for the
appliance to be used safely and sensibly. They shall include in particular:
instructions for the use of the oven: use of the thermostat, position of accessories, if necessary maximum
authorized load for the pastry tray etc.; in particular, these instructions shall include the steps to be taken
for using programmable ovens taking into account food hygiene (e.g. deterioration of food in hot weather);
where appropriate (see 6.1.10.1), the instruction on the need to have the thermostat checked in case
where its failure would cause an abnormal drift in the cooking temperature of the oven;
in the case where the appliance is fitted with a thermostat fault indicator (see 6.1.10.2.3) the instructions
shall include all information necessary concerning its use and the actions to be taken by the user in the
event of a fault indication;
instructions for use of the grill (in particular the position of accessories); they shall state in particular if the
grill is only to be used at its nominal heat input;
the minimum dimensions of the pans to be used on the various burners of the hotplate, and, where
appropriate, specifications on the use of pans with concave or convex bases;
the profile and maximum dimension of the pan to be used with fish burners of useful length greater than
140 mm;
for appliances having one or more burners that are capable of remote operation, a description of type of
remote operation ( type 1 or type 2), together with instructions on the use of the burners concerned both
manually and remotely;
106
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
instructions on how to shut off the burner or burners quickly when operating in the remote mode using a)
the remote means and b) the manual controls on the appliance to override the remote means:
a description of the way in which the user can recognise visually whether the burner or burners are in the
remote operation mode;
information, warning the user against the use of cooking vessels on the hotplate that overlap its edges.
The instructions for use and maintenance shall warn the user against incorrect use of the appliance. To this
end, it shall list any applicable restrictions on the use of the appliance resulting from this European Standard.
In the case of appliances with a cooling fan, the instructions shall include the steps to be taken by the user in
the event of a fault with the fan. If the appliance is fitted with a fan fault indicator, the necessary information
concerning this indicator shall also be specified.
If for cleaning, the manufacturer instructs the user to set the control device to a higher position than for normal
cooking operations, the instructions for use and maintenance shall contain a statement that, under these
conditions, the surfaces may become hotter than in normal use and that children shall be kept away.
For appliances having a gas cylinder compartment, the instructions shall specify the dimensions of cylinders
to be used in the countries in which the appliance may be sold. If necessary, the instructions shall describe
the means of assuring a particular path for the flexible tube used for connection; In addition, the instructions
shall indicate the obligation to replace any means of connection which carry a date limit for use.
The instructions for use and maintenance shall contain the following warnings:
"!CAUTION:"The use of a gas cooking appliance results in the production of !heat, moisture and
products of combustion" in the room in which it is installed. Ensure that the kitchen !is well ventilated
especially when the appliance is in use": keep natural ventilation holes open or install a mechanical
ventilation device (mechanical extractor hood).
Prolonged intensive use of the appliance may call for additional ventilation, for example opening of a window,
or more effective ventilation, for example increasing the level of mechanical ventilation where present".
If the manufacturer instructs the user to use the grill with the door open, the instructions for use and
maintenance shall state in emphasis (e.g. by colour or underlined) the following warning:
"CAUTION: Accessible parts may be hot when the grill is in use. Young children should be kept away".
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
!"CAUTION: This appliance is for cooking purposes only. It must not be used for other purposes, for
example room heating.""
When the appliance does not comply with 6.1.5.1.1.2 as delivered, the instructions shall contain the substance
of the following:
“An additional protective means to avoid contact with the oven door is available. This part should be fitted
when young children are likely to be present.”
The reference number of the part and information on how to obtain it shall be given in the instructions.
If a glass shut-down lid, according to the requirements in 5.2.8.1, carries the symbol described in Annex F,
this symbol shall be reproduced in the instructions for use and maintenance together with an explanation of its
meaning.
If a glass shut-down lid, according to the requirements in 5.2.8.1, carries a warning, this warning shall be
reproduced in the instructions for use and maintenance.
107
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
On delivery of parts intended for conversion to another type of gas or to another pressure, the manufacturer
shall supply adequate and clear instructions for changing the parts and also for cleaning, adjustment and
control of the appliance and renewal of seals following intervention.
After conversion of the appliance to another type of gas or to another pressure than that for which it was
previously adjusted, information on the new adjustment shall be given in place of the previous information, so
as to permit unambiguous identification of the state of the appliance after modification.
If, in order to comply with this requirement, a new plate or label is required, this shall be supplied with the
conversion parts and it shall comply with the requirements of legibility and durability in 8.1.1.
Where appropriate, instructions written in the official language or languages of the country or countries of
destination corresponding to the new adjustment state of the appliance shall be supplied.
Key
1 light
2 grill burner
3 thermostat probe
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
4 door
5 oven accessory in position at the rear stop
6 base
7 back wall
8 rear vertical plane of the cooking zone
a useful height
b useful width or door aperture whichever is smaller
c useful depth
108
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Key
a Class 1. Free standing appliance
b Class 2. Appliances for building-in between two kitchen units
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
109
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Key
1 spring balance
110
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Nominal mass a
h
kg
mm
2,5 24
3,3 31
4,1 38
5 47
6 56
7 65
8 74
9,3 86
10,5 97
a
The values 30 and h are calculated for a material of relative density 7,8 kg/dm3.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
111
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Key
1 test mass
2 graduated scale
112
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Key
1 pressure of the gas cylinder
2 pressure regulator
3 gas cylinder
4 supply to external burner
5 manometer for the supply pressure
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
113
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Key
1 material: steel 15/10
2 ball bearing
3 nickel-chrome sheet steel
4 blade
A top view
Figure 7 — Pendulum for testing the draught resistance of hotplate burners (7.3.2.2)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
114
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Key
1 copper tube diameter 8 thickness 1
2 restrictor
3 steel tube diameter 22 thickness 1
115
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Key
1 copper tube diameter 8 thickness 1
2 restrictor
3 steel tube diameter 22 thickness 1
116
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Dimensions in millimetres
1)
h ≥ 320 mm in order to allow for opening of the shut-down lid or to allow free space between the device and
any high-level grill
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Figure 10 — Verification of combustion of all the burners together - Sampling device (7.3.2.4.2)
Value Dimensions in mm
a 300 500 580 680 710 630 790
b 500 600 700 680 780 1 140 1 000
Dimensions a and b of the sampling hood are shown according to the requirements of 7.3.2.4.2.
The seven examples for which dimensions are given above cover the majority of hotplates encountered.
117
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Key
1 regulator with friction spring
2 ∅ 8 sampling tube
3 annular baffle
118
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Key
a appliance width
x1 see 7.3.1.5.1.2.
x2 see 7.3.1.5.1.2
Figure 12 — Example of test installation for appliances of class 1 and class 2 sub-class 1 (7.1.3.3.1,
7.1.3.3.2.1, 7.3.1.5.1.2)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
119
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Dimensions in millimetres
Key
1 hotplate
2 the horizontal partition shall have critical dimensions specified by the manufacturer
3 position and dimensions according to manufacturer's instructions
4 oven
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
120
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex A
(informative)
National situations
A.1 General
In each country in which this European Standard applies, appliances may be marketed only if they comply
with the particular national supply conditions of that country.
In order to permit, both at the time of testing the appliance and at the time of its sale, the correct choice to be
made from all the situations covered, the various national situations are summarised in Tables A.1, A.2, A.3,
A.4, A.5 and A.6.
NOTE Some of the tables in this Annex are incomplete. This is because the CEN TC 49 Secretariat has not received
the relevant information from the CEN member countries concerned prior to the publication of this Standard.
Queries concerning such information should be addressed to those CEN member countries.
A.2 Marketing in different countries of the categories listed in the text of the
standard
Tables A.1 and A.2 give the situations concerning the marketing, in various countries, of the categories of
appliance listed in the text of the standard.
The information given in these tables does not mean that these categories can be marketed throughout the
territory of the country concerned; A.4, shall be consulted for the purposes of verification.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
In case of doubt, the local gas distributor shall be consulted on the categories which apply.
121
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Country I2H I2L I2E I2E+ I2N I2R I3B/P I3+ I3P I3B a I3R a
code
AT x x
BE x x
b
BG
CH x x x x
b
CY
CZ x x x x
DE x x x
DK x x
b
EE
ES x x x
FI x x x
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
FR x x
GB x xc x x
GR x x x x
b
HU
IE x x x
IS x
IT x x
b
LT
LU x
b
LV
b
MT
NL x x x
NO x
b
PL
PT x x
b
RO
SE x x
SK x x x
Sl x x x x x x
a
Category not selected by any country; for the definition of the category see !EN 437:2003+A1:2009".
b
Information on categories to be supplied by new CEN member.
c
Category applicable only for appliances installed in Touring and Motoring Caravans.
122
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
AT X
BE X
b
BG
CH X X X
b
CY
CZ X X X
DE X
DK X X
EE b
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
ES X X
FI X
FR X
GB X X
GR X X X
b
HU
IE X X
b
IS
IT X X
b
LT
LU b
LV b
MT b
NL X X
NO
PL b
123
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Country code II 1a2H II 2H3B /P II 2H3+ II 2H3P II 2L 3B/P II 2L 3P II 2E3B /P II 2E+3+ II 2R3R a)
+
PT X
b
RO
SE X X
SK X X
Sl X X X
a
Category not selected by any country; for the definition of the category see !EN 437:2003+A1:2009".
b
Information on categories to be supplied by new CEN member.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
125
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
AT X X X
BE X X X
b
BG
CH X X X X
b
CY
CZ Xc X X Xd X
DE X X X X
DK X X X X
EE b
ES X X X X X
FI X X X
FR X X
GB X X X X
GR X X X X X
b
HU X X X
IE X X X
b
IS
IT X X X
b
LT
LU
LV b
MT b
NL X X X X
NO X X
PL b
PT X X X X
b
RO
SE X X X X
SK X X X X X
Sl X X X X
a
See Table 9, footnote to table b.
b
Information on supply pressures to be supplied by new CEN members.
c
Currently 18 mbar.
d
For certain types of system (CZ to clarify).
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
126
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The national or local distribution conditions (composition of gases and supply pressures) result in the definition
of particular categories which are sold nationally or locally in certain countries, in accordance with Table A.4.
G 271
G 31 G 31,
G32
a
II2S3B G 25.1, G30 G 26.1, G30 G 32 G 27.1, G31 G 26.1, G 30 HU
G 30
A.4.2 Categories
The categories from Table A.4 are defined in accordance with the information in 4.2, observing the
characteristics of the gases distributed regionally as shown in Table A.5.
127
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
A.4.2.1 Category I
A.4.2.1.1 Appliances designed for use with gases attached to the first family
Category I1b: Appliances using only gases of group b attached to the first family, at fixed supply pressure (this
category is not used).
Category I1c: Appliances using only gases of group c attached to the first family, at fixed supply pressure (this
category is not used).
A.4.2.1.2 Appliances designed for use with gases of the second family or gases attached to it
Category I2LL: Appliances using only gases of group LL attached to the second family, at fixed supply
pressure. Provided that the Wobbe index of the gas distributed from the second family does not exceed the
3
upper value of 43,7 MJ/m , the appliance may be adjusted according to a lower nominal value (this category
is not used).
Category I2ELL: Appliances likely to be used with gases of group E of the second family, and gases of
group LL attached to the second family. Gases of the second family of group E are used under the same
conditions as for category I2E. Gases of the second family of group LL are used under the same conditions as
for category I2LL.
Category I2S: appliances using only gases of group S linked to the second family, at the defined supply pressure.
Category I2HS: appliances using only gases of group H of the second family and gases of group S linked to the
second family. The group H second family gases are used under the same conditions as for category I2H. The
group S second family gases are used under the same conditions as for category I2S.
A.4.2.2 Category II
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
A.4.2.2.1 Appliances designed for use with gases of the first family or gases attached to it, and
gases of the second family or gases attached to it
Category II1c2E+: Appliances likely to be used with gases of group c attached to the first family and gases of
group E of the second family. Gases attached to the first family are used under the same conditions as for
category I1c. Gases of the second family are used under the same conditions as for category I2E+.
A.4.2.2.2 Appliances designed for use with gases of the second family or gases attached to it and
gases of the third family
Category II2ELL3B/P: Appliances likely to be used with gases of group E of the second family, gases of
group LL attached to the second family and gases of the third family. Gases of the second family or gases
attached to it are used under the same conditions as for category I2ELL. Gases of the third family are used
under the same conditions as for category I3B/P.
Category II2S3B/P: appliances capable of using gases of group S linked to the second family and gases of the third
family. The gases linked to the second family are used under the same conditions as for category I2S. The third
family gases are used under the same conditions as for category I3B/P.
Category II2S3P: appliances capable of using gases of group S linked to the second family and gases of group P
of the third family. The gases linked to the second family are used under the same conditions as for category I2S.
The third family gases are used under the same conditions as for category I3P.
128
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Category II2S3B: appliances capable of using gases of group S linked to the second family and gases of group B
of the third family. The gases linked to the second family are used under the same conditions as for category I2S.
The third family gases are used under the same conditions as for category I3B.
Category II2HS3B/P: appliances capable of using gases of group H of the second family, gases of group S linked to
the second family and gases of the third family. Gases of the second family or gases linked to it are used under
the same conditions as for category I2HS. The third family gases are used under the same conditions as for
category I3B/P.
Category II2HS3P: appliances capable of using gases of group H of the second family, gases of group S linked to
the second family and gases of group P of the third family. Gases of the second family or gases linked to it are
used under the same conditions as for category I2HS. The third family gases are used under the same conditions
as for category I3P.
Category II2HS3B: appliances capable of using gases of group H of the second family, gases of group S linked to
the second family and gases of group B of the third family. Gases of the second family or gases linked to it are
used under the same conditions as for category I2HS. The third family gases are used under the same conditions
as for category I3B.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
A.4.2.3 Category III
Category III1a2H3+: appliances capable of using gases of group a of the first family, gases of group H of the
second family and gases of the third family. The first family gases are used under the same conditions as for
category I1a. The second family gases are used under the same conditions as for category I2H. The third family
gases are used under the same conditions as for category I3+.
Category III1a2H3B/P: appliances capable of using gases of group a of the first family, gases of group H of the
second family and gases of the third family. The first family gases are used under the same conditions as for
category I1a. The second family gases are used under the same conditions as for category I2H. The third family
gases are used under the same conditions as for category I3B/P.
Category III1c2E+3+: appliances capable of using gases of group c linked to the first family, gases of group E of the
second family and gases of the third family. The gases linked to the first family are used under the same
conditions as for category I1c. The second family gases are used under the same conditions as for category I2E+.
The third family gases are used under the same conditions as for category I3+.
Category III1ab2H3B/P: appliances capable of using gases of group a of the first family, gases of group c linked to
the first family, gases of group H of the second family and gases of the third family. The first family gases or the
gases linked to it are used under the same conditions as for categories I1a and I1b. The second family gases are
used under the same conditions as for category I2H. The third family gases are used under the same conditions as
for category I3B/P.
For these appliances, annulment of the function of nominal rate adjusters is obligatory in the second and
third family, annulment of the function of reduced gas rate adjusters is obligatory in the third family.
1) for adjustment of the nominal rate for categories I2ELL, II2ELL 3B/P;
2) for adjustment of the reduced rate for categories I2ELL, II2ELL 3B/P.
129
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The presence of primary air intake adjusters is optional for all categories, with the exception of categories for
which it is prohibited28).
For categories IIlc2E+, IIIlc2E+3+, the requirements of 5.1.1.3 and 5.1.1.4 are applicable.
change of injectors;
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
130
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-
Table A.5 — Gas characteristics (dry gas at 15 °C and 1 013,25 mbar) and test pressures corresponding to national and local situations
Gas family and group Nature of Designation Composition WI HI Ws Hs d Test Country
gas Volume Pressure
MJ/m3 MJ/m3 MJ/m3 MJ/m3 mbar
%
Group c Reference G 130 C3H8 = 26,9 22,14 23,66 24,07 25,72 1,142 pn = 8
(Propane–air) Air = 73,1 a FR
pmin = 6
Light back G 132 C3H8 = 13,8 22,10 23,56 23,84 25,41 1,136
pmax = 15
C3H6 = 13,8
Air a = 72,4
131
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
132
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
BG
a
CH Yes Yes No Yes Yes a No No
CY
CZ
EE
HU
IS
LT
LU
LV
MT
NO Yes Yes No No No No No
PO
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
RO
133
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex B
(informative)
When an appliance meets the requirements of one or more categories, in order to establish its conformity with
one or more other categories, it is necessary to verify that the appliance satisfies all the requirements of this
new category or categories.
To this end, the tests required for the new category or categories shall be compared with those carried out for
the previous category or categories, in order to determine which additional tests are required.
These additional tests will be limited to the minimum necessary to ensure that the appliance will meet the
requirements applicable to the new category or categories.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
134
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex C
(normative)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
C.1 Pans required for testing on gas burners
The pans required for testing are aluminium sauce pans of commercial quality.
The pans required for testing on gas burners shall comply with Figure C.1 and their dimensions shall comply
with Table C.1.
Key
A internal diameter measured at the top
H internal height
C thickness of base
D thickness of the side
E internal radius
135
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
lid a
a
Mass without handles calculated for lids in aluminium (relative density 2 700 kg/m3) and given for guidance.
If the cooking plate has a diameter other than those indicated in the table, the diameter of the saucepan and
the quantity of water, at ambient temperature, will be as specified for the next highest nominal diameter.
In case of doubt, standard test saucepans of commercial aluminium, having the dimensions given in Table C.2
and as shown in Figure C.2 below, are used.
Dimensions in millimetres
Key
a external diameter
b external height
c thickness of base
137
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex D
(normative)
D.1 Design
The temperature probe used to measure surface temperatures complies with Figure D.1.
Dimensions in millimetres
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Key
1 adhesive
2 thermocouple wires 0,3 diameter to EN 60584-1:1995 type K (chrome alumel) total length (1 500 ± 2)
3 handle arrangement permitting contact force of (4 ± 1) N, length (100 ± 2), external diameter (25 ± 2)
4 polycarbonate tube inside diameter 3, outside diameter 5. In output position (100 ± 2) in length
5 tinned copper disc 5 diameter 0,5 thick
The contact surface of the disk shall be flat. The thermocouple shall be welded with care using the minimum
of solder to ensure that the temperature of the disk is measured.
D.2.1 Principle
The probe is applied to the centre of a flat glass plate, the lower surface of which is in contact with the water
vapour.
D.2.2 Procedure
Distilled water is placed in a "beaker-type" container with a pouring lip, approximately 260 mm high and
165 mm in diameter.
138
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
The water is brought to the boil by means of an electric plate of diameter 145 mm.
D.2.3 Validation
The probe is suitable for use when it indicates at equilibrium a value of (85 ± 3) °C after a contact time not
exceeding 150 s.
Dimensions in millimetres
Key
1 surface temperature probe
2 flat, toughened glass plate 5 ± 0,2 thick
3 distilled water height 200 ± 2,5
4 ambient temperature = 20 °C ± 2 °C, Ambient air speed ≤ 0,1 m/s
5 electric cooking plate of output 1 000 W ± 100 W diameter ≈ 145
6 beaker with pouring spout. Capacity 5 L. Height ≈ 260. Internal diameter ≈ 165
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
The probe shall be placed at not less than 30 mm from the rim of the beaker, not in the path of condensation
droplets.
Figure D.2 — Test apparatus for the validation of the surface temperature probe
139
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex E
(normative)
In order to represent all the numbers of categories corresponding to an appliance adjustment, the reference
gas symbol common to all these numbers shall be used, as shown in Table E.1.
1st family a:
G 110 1a
G 120 1b
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
G 130 1c
G 150 1e
2nd family:
G 20 2H, 2E, 2E+, 2ELL b
G 25 2L, 2ELL c
3rd family:
G 30 3B/P, 3+ d f
G 31 3+ e f, 3P
a If the appliance, in its adjusted state, can use gases of different groups, reference shall be made to all the reference gases
corresponding to these groups.
b If the appliance is adjusted for G 20.
c If the appliance is adjusted for G 25.
d Only applies to appliances which do not require adjustment between G 30 and G 31 or to appliances which require an
adjustment and which are adjusted for G 30.
e Only applies to appliances which require adjustment between G 30 and G 31 and which are adjusted for G 31.
f For appliances which require adjustment between G 30 and G 31, the label showing adjustment to a different gas and
pressure couple shall be supplied with the technical instructions.
NOTE The table needs to be modified to take account of gases distributed in new CEN member states.
140
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
E.1.3 Pressure
The unit (mbar) may be considered sufficient to identify this value. However, if a symbol has to be used for
pressure, p should be used.
E.1.4 Country
In accordance with EN ISO 3166-1:2006, the names of countries shall be represented by the following codes:
AT Austria IE Ireland
BE Belgium IS Iceland
BG Bulgaria IT Italy
CH Switzerland LT Lithuania
CY Cyprus LU Luxembourg
CZ Czech Republic LV Latvia
DE Germany MT Malta
DK Denmark NL Netherlands
EE Estonia NO Norway
ES Spain PL Poland
FI Finland PT Portugal
FR France RO Romania
GB United Kingdom SE Sweden
GR Greece SK Slovakia
HU Hungary Sl Slovenia
E.1.5 Category
The category may be identified solely by its designation in accordance with !EN 437:2003+A1:2009".
Nevertheless, if an explanation is necessary, the term "Category" shall be symbolised by "Cat.".
E.2.1 General
The symbols given below are not obligatory, but are recommended as preferential, and to the exclusion of any
other symbol, to avoid the use of many various markings.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
141
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
E.3 Information having to appear on the appliance and its packaging, in accordance
with 8.1 and 8.2
For the time being, in order to satisfy the needs expressed by CEN Members (see Table E.1), it is permitted
that their declared means of identification appears, in addition to the symbol for the type of gas.
142 --`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
Table E.2 — Means of identification of the types of gas in force in the various countries
Type of G 110 G 120 G 130 G 150 G 20 G 25 G 30 G 31
gas
Country
b
code
AT Erdgas Flüssiggas
BE Aardgas, Aardgas, Butaan, Propaan,
Gaz naturel Gaz naturel Butane Propane
CH Erdgas H Butan Propan
BG
CY
CZ
DE Erdgas E Erdgas LL Flüssiggas B/P
Wo,(12,0 – Wo, (10,0 – Butan Propan
15,7) 13,1)
kWh/m3 kWh/m3
0 °C 0 °C
DK Bygas Naturgas F-Gas F-Gas
EE
ES Gas Aire Aire Gas natural Butano Propano
manufacturado propanado metanado
FI Maakaasu, Butaani, Propaani,
Naturgas Butan Propan
FR a Air propané/ Gaz naturel Gaz naturel Butane Propane
Air butané Lacq Groningue
GB Natural Gas Butane Propane
GR Quσικò Yγραèριo Πρoπανιo
Aèpιo Mεiγµα
HU
IE Natural Gas Butane Propane
IS
IT Gas di Città Gas GPL
naturale/
Gas metano
LT
LU
LV
MT
NL Aardgas Butaan Propaan
NO Butan Propan
PL
PT Gás Natural Butano Propano
SE
RO
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
143
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
144
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex F
(normative)
Key
Diameter: at least 50 mm
Colour: Circle and stroke: red
Flames: blue
Hotplate and lid: black
Figure F.1 — Symbol “Do not shut lid when burner alight”
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
145
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Annex ZA
(informative)
This European Standard has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association to provide a means of conforming to Essential Requirements of the
New Approach Directive 90/396/EEC on the approximation of the laws of Member States concerning gas
appliances.
WARNING : Other requirements and other EU Directives may be applicable to the products falling
within the scope of this standard.
The following clauses of this standard are likely to support requirements of 90/396/EEC Directive on the
approximation of the laws of Member States concerning gas appliances.
Compliance with clauses of this standard provides one means of conforming to the specific essential
requirements of the Directive concerned and associated EFTA regulations.
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
146
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Table ZA.1
1 Annex 1
General conditions
2 Materials
3.1 General
3.1.1 Safety of construction and 5.1.2, 5.1.4, 5.1.6, 5.1.7, 5.1.8, 5.2.1, 5.2.8,
durability 5.2.9, 5.2.10 and 6.1.4.1
3.1.4 Penetration of water and air 5.1.5 and 6.1.1 "Penetration of water" :
not applicable
3.1.12 Marking of adjusting and control 5.2.2.2, 5.2.4, 5.3 and 7.2.3
devices
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
147
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
3.2.2 Risk of accumulation in the 5.2.6, 5.2.9.1.4, 5.2.12, 6.1.3, 6.2.1, 6.3.1 and
appliance 6.1.4.2.2
3.2.3 Risk of accumulation in the space 5.2.6, 6.1.3, 8.1, 8.2, 8.3.2.2 and 8.3.3
3.3 Ignition
Ignition 5.2.5, 5.2.9.2, 5.2.12.2, 6.1.9.2, 6.1.9.3, 6.2.1,
6.3.1, 5.2.12.3, 6.2.1, 6.3.1 (tests 7.3.2.1.3
and 7.3.3.1.3) 6.2.1 and 6.3.1
Re-ignition
Cross-lighting
3.4 Combustion
3.6 Temperatures
3.7 Foodstuffs and water used for 5.1.2 and 5.2.13 "Water used for
sanitary purposes sanitary purposes": not
applicable
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
148
标准分享网 www.bzfxw.com 免费下载
BS EN 30-1-1:2008+A1:2010
EN 30-1-1:2008+A1:2010 (E)
Bibliography
[1] EN ISO 6976:2005, Natural gas — Calculation of calorific value, density, relative density and Wobbe
index from composition (ISO 6976:1995 including Corrigendum 1:1997, Corrigendum 2:1997 and
Corrigendum 3:1999)
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---
149
BS EN 30-1-1:2008
+A1:2010
BSI - British Standards Institution
BSI is the independent national body responsible for preparing British
Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of British
Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover. Tel:
+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996
7001 Email: [email protected] You may also buy directly using a debit/credit
card from the BSI Shop on the Website http://www.bsigroup.com/shop
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which
give details on all its products and services. Contact Information Centre. Tel:
+44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: [email protected]
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration. Tel: +44 (0)20
8996 7002 Fax: +44 (0)20 8996 7001 Email: [email protected]
Information regarding online access to British Standards via British Standards
Online can be found at http://www.bsigroup.com/BSOL
Further information about BSI is available on the BSI website at http://
www.bsigroup.com
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may
be reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
BSI Group permission from BSI.
Headquarters 389 This does not preclude the free use, in the course of implementing the standard,
Chiswick High Road, of necessary details such as symbols, and size, type or grade designations. If
London, W4 4AL, UK these details are to be used for any other purpose than implementation then the
Tel +44 (0)20 8996 9001 prior written permission of BSI must be obtained.
Fax +44 (0)20 8996 7001
www.bsigroup.com/ Details and advice can be obtained from the Copyright and Licensing Manager.
standards Tel: +44 (0)20 8996 7070 Email: [email protected]
--`,,,,`,,`,,```,`,,`,``,`,,`,`,-`-`,,`,,`,`,,`---