Electric Heater Datasheet: Case 1A Case 1B Case 2 Case 3 Case 4 Case 5
Electric Heater Datasheet: Case 1A Case 1B Case 2 Case 3 Case 4 Case 5
Electric Heater Datasheet: Case 1A Case 1B Case 2 Case 3 Case 4 Case 5
64 END CAP NOT IN VULCANIC SCOPE H1 (N3) HEATER 10 600 N/A N/A RFBL
65 FLANGES ASTM A182-F316L N1 INLET 4 600 200 0 RFWN
66 PLATE NOT IN VULCANIC SCOPE N2 OUTLET 4 600 400 0 RFWN
67 BOLTS/NUTS NOT IN VULCANIC SCOPE N4 DRAIN 2 600 200 180 RFWN
68 BAFFLES/TIE RODS Type 316 St.Steel. N5 TT 2 600 200 N/A RFWN
69 GASKETS NOT IN VULCANIC SCOPE
70 ELEMENT SHEATH Incoloy 800
71 MAIN ENCLOSURE Stainless Steel 316/316L
72 INST. ENCLOSURE N/A
73 OFFSET SLEEVES Incoloy 800
74 SENSOR POCKET Incoloy 800
75 NACE MR-01-75 / ISO 15156 MATERIAL CERTIFICATION EN 10204 3,1
76 PAINTING ENCLOSURE No Painting Required
77 PAINTING FLANGE NORSOK Coating System 6 Intertherm® 228 NORSOK PC SYSTEMS GUIDE DOC
78 PAINTING VESSEL NOT IN VULCANIC SCOPE
79 HYDROTEST To Code
80 TESTING As per quotation summary
81 HEATER WILL BE OF WELDED CONSTRUCTION.
82 TEMPERATURE SENSORS WILL BE TERMINATED IN TRANSMITTERS FOR CLIENT CONNECTION.
Vulcanic UK Ltd
South Green Park
www.vulcanic.com
+44 (0) 1603 340015
DRAWN CHECKED DATED DRAWING No REV
Enterprise Centre
Mattishall
7
Dçereham
Norfolk
Marking: CE II 2 G IIC T3 Gb for operation within an ambient temperature from -20°C up to 60°C, and maximum
humidity 95%. Equipment of CAT 2 for surface industries, for use in a hazardous area classified Zone 2 Gas Group
IIC environment, where the self-ignition temperature is lower than 200 Deg C
- The temperature safety devices must switch off the power supply, by means of a “fail safe” circuit(a manual reset is necessary).
The set points are written in the contractual file.
- Precautions must be taken so that the heating elements are never in contact with an explosive gas.
- When it is electrically supplied, the heater must be protected with a mass flow switch which removes power to the heater in the
event that the mass flow falls below the minium value.The low flow device must switch off the power supply, by means of a “fail
safe” circuit (a manual reset is necessary). The set points are written in the contractual file.
100 In operating conditions, the maximum temperature of the vessel must not exceed the values defined below :-
Temperature class : T1 T2 T3 T4 T5 T6
Marking temperature : 450°C 300°C 200°C 135°C 100°C 85°C
Maximum safety setting : 440°C 290°C 195°C 130°C 95°C 80°C
Max. advisable flange temp : 430°C 280°C 190°C 125°C 90°C 75°C
Otherwise, the user must install appropriate insulation : high-density mineral wool laid in a minimum of 2 thicknesses cross-laid so
that no points of the vessel and the hardware come into contact with the dangerous atmosphere. Unless specified otherwise, the
junction box must be placed in an atmosphere varying from between -20°C and 60°C.
101 CABLE GLANDS HAVE NOT BEEN ALLOWED FOR. GLAND PLATE PROVIDED UNDRILLED.
102 VESSEL, BOLTS, GASKET HAVE NOT BEEN ALLOWED FOR.
103 Element sheath/Skin temp protection covered by HI-Hi sensor
104 ALL PROCESS CASES IN DOC REF: 05-1_EPC-SV-AEI-P-DS-45001 (REVC2) HAVE BEEN CONSIDERED.
105 231KW DUTY PROVIDED AS PER CLIENT REQUEST..
106 HEATER GIRTH FLANGE BOLTING AND GASKETS NOT CONSIDERED UNDER VULCANIC SCOPE.
107 VESSEL TEMPERATURE SENSOR WILL BE SUPPLIED FOR LOOSE FOR INSTALLATION ON VESSEL BY OTHERS.
108
109
110
111