ELECTRIC HEATER DATASHEET

1 HEATER DESCRIPTION FUEL GAS SUPERHEATER CUSTOMER ROVAC


2 HEATER Tag No SV-45-FE-001A/B
3 PROCESS MEDIUM HYDROCARBON GAS
4 DUTY BUNDLE(@NOM VOLTAGE) 231 kW 400 VOLTS 50 Hz
5 DUTY HEATER (@NOM VOLTAGE) 231 kW DELTA
6 PROCESS DETAILS CASE 1A CASE 1B CASE 2 CASE 3 CASE 4 CASE 5
7 MASS FLOW RATE (kg/h) 11680,69 11680,69 11680,69 11680,69 11680,69 11680,69
8 INLET TEMP (deg.C) 38,8 42,00 38,88 19,14 42,00 30,80
9 OUTLET TEMP (deg.C) 68,8 72,00 68,88 49,14 72,00 60,80
10 SPECIFIC HEAT (kJ/kg.K) 2,181 2,179 2,164 2,107 2,179 2,1475
11 THERMAL COND (w/m.k) 0,037 0,037 0,037 0,035 0,037 0,036
12 MOLECULAR WEIGHT 20,45 21,35 20,15 20,24 21,35 20,48
13 VISCOCITY (cp) 0,0126 0,0126 0,0127 0,0123 0,0126 0,0125
14 PRESSURE DROP (bar.g) ≤0,3 ≤0,3 ≤0,3 ≤0,3 ≤0,3 ≤0,3
15 OPERATING PRESSURE (bar.g.) 27 27 27 27 27 27
16 HEAT EXCHANGED (kW) 212,30 211,9 210,5 204,9 211,9 208,9
17 ELEMENT DETAILS BUNDLE 1 BUNDLE 2 BUNDLE 3 BUNDLE 4 BUNDLE 5 BUNDLE 6
18 No. ACTIVE/TYPE 21 HAIRPIN
19 No. SPARE 4 UNCONNECTED
20 No. STAGES 1
21 No. ACTIVE ELEMENTS PER STAGE 21
22 DIAMETER (mm) 16
23 ACTIVE 'U' (mm) 1479
24 TOTAL LOAD (KW) 231
25 ELEMENT LOAD (KW) 11,00
26 VOLTAGE 400
27 FLUX (W/SQ.CM) 7,40
28 MAXIMUM SHEATH TEMP (deg.C) 190
29 BAFFLE DETAILS BUNDLE 1 BUNDLE 2 BUNDLE 3 BUNDLE 4 BUNDLE 5 BUNDLE 6
30 BAFFLE PITCH (mm) 152,4
31 BAFFLE CUT / TYPE ROD
32 BAFFLE THK (mm) 3
33 No. OF TIE RODS 4
34 TIE RODS DIA (mm) 10
35 TEMPERATURE DEVICES ACTIVE SET Deg C SENSOR TYPE TRANSMITTER
36 ELEMENT HI (Per Bundle)
37 ELEMENT HI HI (Per Bundle) 3 220 T/C TYPE K SIMPLEX Exe Note 87
38 PROCESS (Per Heater)
39 TEMP CLASS PROTECTION 1 140 T/C TYPE K SIMPLEX Exe Note 89
40 OTHER
41 HAZARDOUS AREA CERTIFICATION
42 PROTECTION TYPE Exe
43 ZONE 2 ATEX MARKING II 2 G IIC T3 Gb
44 GAS GROUP IIC
45 TEMP CLASS T3 Gb
46 DESIGN DATA
47 DESIGN CODE ASME VIII Div 1
48 PED COMPLIANT NO - OUTSIDE EU
49 DESIGN PRESSURE (BAR.G) 34,5
50 DESIGN TEMP (DEG.C) -20 to 150
51 CORR ALLOW' (mm) 0
52 RADIOGRAPHY (%) 100% (VESSEL) NOT IN VULCANIC SCOPE
53 AMBIENT (DEG.C) 21 to 32
Vulcanic UK Ltd
South Green Park
www.vulcanic.com
+44 (0) 1603 340015
DRAWN CHECKED DATED DRAWING No REV
Enterprise Centre
Mattishall
7
Dçereham
Norfolk

WPS BH 13/04/18 206523-HDS-SV-45-FE-001AB PAGE 1/3


ELECTRIC HEATER DATASHEET

VESSEL SIZING INDICATIVE ONLY. NOT IN VULCANIC SCOPE.


54 WEIGHTS DIMENSIONS (MM)
55 BUNDLE WEIGHT Kg 261 A B C D C2 E F G
56 TOTAL - EMPTY Kg 588 250 150 64 2064 285 1636 200
57 TEST WEIGHT Kg 645 H I J K
58 HEAT TRANSFER DATA 300 1464 579
59 TOTAL SURF.AREA M2 3,12
60 HTC w/m2c 610,56
61 MEAN TEMP DIFF Deg c 121,20
62 MATERIALS - NOTE 102 CONNECTIONS
63 SHELL NOT IN VULCANIC SCOPE REF NAME SIZE CLASS PROJECTION ORIENTATION TYPE

64 END CAP NOT IN VULCANIC SCOPE H1 (N3) HEATER 10 600 N/A N/A RFBL
65 FLANGES ASTM A182-F316L N1 INLET 4 600 200 0 RFWN
66 PLATE NOT IN VULCANIC SCOPE N2 OUTLET 4 600 400 0 RFWN
67 BOLTS/NUTS NOT IN VULCANIC SCOPE N4 DRAIN 2 600 200 180 RFWN
68 BAFFLES/TIE RODS Type 316 St.Steel. N5 TT 2 600 200 N/A RFWN
69 GASKETS NOT IN VULCANIC SCOPE
70 ELEMENT SHEATH Incoloy 800
71 MAIN ENCLOSURE Stainless Steel 316/316L
72 INST. ENCLOSURE N/A
73 OFFSET SLEEVES Incoloy 800
74 SENSOR POCKET Incoloy 800
75 NACE MR-01-75 / ISO 15156 MATERIAL CERTIFICATION EN 10204 3,1
76 PAINTING ENCLOSURE No Painting Required
77 PAINTING FLANGE NORSOK Coating System 6 Intertherm® 228 NORSOK PC SYSTEMS GUIDE DOC
78 PAINTING VESSEL NOT IN VULCANIC SCOPE
79 HYDROTEST To Code
80 TESTING As per quotation summary
81 HEATER WILL BE OF WELDED CONSTRUCTION.
82 TEMPERATURE SENSORS WILL BE TERMINATED IN TRANSMITTERS FOR CLIENT CONNECTION.
Vulcanic UK Ltd
South Green Park
www.vulcanic.com
+44 (0) 1603 340015
DRAWN CHECKED DATED DRAWING No REV
Enterprise Centre
Mattishall
7
Dçereham
Norfolk

WPS 13/04/18 206523-HDS-SV-45-FE-001AB PAGE 2/3


ELECTRIC HEATER DATASHEET

83 ANTICONDENSATION HEATER 50W 230V(Exe Certified)


84 PICKLE AND PASSIVATION Not Included
85 TEMPERATURE TRANSMITTERS
86 ELEMENT HI (Per Bundle) Not Fitted
87 ELEMENT HI HI (Per Bundle) 3x 4-20mA Smart HART Exd, Aluminium Head Mount Enclosure, with LCD
88 PROCESS (Per Heater) Not Fitted
89 TEMP CLASS PROTECTION 1x 4-20mA Smart HART Exd, Aluminium Head Mount Enclosure, with LCD
90 OTHER NOTE 103
91 INSULATION By Others (See Note 100)
92 LIFTING LUGS Yes
93 JACKING SCREWS NA
94 PMI Not Included
95 IP RATING IP66
96 SUNSHADE No
97 U-STAMP Partial (MDS supplied to vessel manufacturer for U-stamp).
98 SPECIAL REQUIREMENT FOR SAFE OPERATION
99
The assembly complies with the requirements of IEC 60079-0: Latest version (Explosive atmospheres - Part 0: General
requirements and IEC 60079-7: 2Latest version (Explosive atmospheres - Part 7: Equipment protection by increased safety "e").

Marking: CE II 2 G IIC T3 Gb for operation within an ambient temperature from -20°C up to 60°C, and maximum
humidity 95%. Equipment of CAT 2 for surface industries, for use in a hazardous area classified Zone 2 Gas Group
IIC environment, where the self-ignition temperature is lower than 200 Deg C

- The temperature safety devices must switch off the power supply, by means of a “fail safe” circuit(a manual reset is necessary).
The set points are written in the contractual file.
- Precautions must be taken so that the heating elements are never in contact with an explosive gas.
- When it is electrically supplied, the heater must be protected with a mass flow switch which removes power to the heater in the
event that the mass flow falls below the minium value.The low flow device must switch off the power supply, by means of a “fail
safe” circuit (a manual reset is necessary). The set points are written in the contractual file.

100 In operating conditions, the maximum temperature of the vessel must not exceed the values defined below :-

Temperature class : T1 T2 T3 T4 T5 T6
Marking temperature : 450°C 300°C 200°C 135°C 100°C 85°C
Maximum safety setting : 440°C 290°C 195°C 130°C 95°C 80°C
Max. advisable flange temp : 430°C 280°C 190°C 125°C 90°C 75°C

Otherwise, the user must install appropriate insulation : high-density mineral wool laid in a minimum of 2 thicknesses cross-laid so
that no points of the vessel and the hardware come into contact with the dangerous atmosphere. Unless specified otherwise, the
junction box must be placed in an atmosphere varying from between -20°C and 60°C.

101 CABLE GLANDS HAVE NOT BEEN ALLOWED FOR. GLAND PLATE PROVIDED UNDRILLED.
102 VESSEL, BOLTS, GASKET HAVE NOT BEEN ALLOWED FOR.
103 Element sheath/Skin temp protection covered by HI-Hi sensor
104 ALL PROCESS CASES IN DOC REF: 05-1_EPC-SV-AEI-P-DS-45001 (REVC2) HAVE BEEN CONSIDERED.
105 231KW DUTY PROVIDED AS PER CLIENT REQUEST..
106 HEATER GIRTH FLANGE BOLTING AND GASKETS NOT CONSIDERED UNDER VULCANIC SCOPE.
107 VESSEL TEMPERATURE SENSOR WILL BE SUPPLIED FOR LOOSE FOR INSTALLATION ON VESSEL BY OTHERS.
108
109
110
111
Vulcanic UK Ltd
South Green Park
www.vulcanic.com
+44 (0) 1603 340015
DRAWN CHECKED DATED DRAWING No REV
Enterprise Centre
Mattishall
7
Dçereham
Norfolk

WPS 13/04/18 206523-HDS-SV-45-FE-001AB PAGE 3/3