Ancon 25-14 Restraint System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Fixing to Steel

Ancon 25/14
Restraint System
The Ancon 25/14 Restraint System ties an outer
leaf of brickwork to a light steel frame.
Self-drilling, high-thread screws fix through the channel
and the insulation and into the steel. Ancon SD25 wall
ties are located in the channel and built into the bed
joints of the outer leaf of brickwork.
This system is suitable for use with rigid insulation up to
a depth of 220mm and ROCKWOOL Rainscreen Duo
Slab™ up to 180mm. When using other semi-rigid or
flexible insulations, an Ancon Compression Sleeve is
required with the fixings.
This system has been independently tested by
Lucideon and a CE Declaration of Performance is
available to download from www.ancon.co.uk/CE.
System Components
25/14 Channel
Lengths: 2700, 3000mm
High-thread Fixing Screws
Lengths: For an insulation depth up to 220mm
SD25 Wall Ties
Lengths: For open cavities up to 259mm

Wall Tie Screw


Length Length

55mm
Design
Embedment

Open Cavity Insulation/


Backing
Material Depth

Warranty
Ancon provides a warranty on its stainless steel 25/14 system,
guaranteeing the design performance for 60 years. When using our
zinc plated fixing screws, a 25 year warranty is offered. Contact
Ancon for full details and conditions.
BIM
A BIM object is available to download from www.ancon.co.uk/BIM
or the NBS National BIM Library.
Ancon 25/14 Channel Ancon High-Thread Fixing Screws
25/14 channel is available in lengths of Screws are available to accommodate a combined backing board and insulation thickness
2700mm and 3000mm. It features pre- of up to 220mm and a steel thickness from 1.2mm to 3mm. Ancon Fixing Screws feature a
punched holes (5.3mm diameter) at close shaped drill tip of hardened steel that allows installation without pre-drilling. Drive sockets are
centres to ensure a fixing position is always available. See tables for correct screw reference and fixing centres.
located near the end, even when it is cut
on site. The channel has a 16mm opening Stainless Steel Fixing Screws

to easily accommodate a drive socket and Insulation/Backing Material Ancon Screw Screw Length
washer for the fixing screws. Thickness (mm) Reference (mm)
27-46 HTSS-65-2PT-W 65
35-61 HTSS-82-2PT-W 82
43-79 HTSS-100-2PT-W 100
14mm 60-94 HTSS-115-2PT-W 115
65-114 HTSS-135-2PT-W 135
80-129 HTSS-150-2PT-W 150
110-159 HTSS-180-2PT-W 180
16mm
165-220 HTSS-240-2PT-W 240
25mm Notes: Suitable for rigid insulations up to 220mm and ROCKWOOL Rainscreen Duo Slab™ up to 180mm, without
Ancon 25/14 Channel Profile an Ancon Compression Sleeve. Carbon steel screws are available. The Ancon 25/14 system is also suitable for
fixing to timber and concrete. Contact Ancon for more details.

Ancon SD25 Wall Ties


Ancon SD25 wall ties are available in various lengths to suit open cavities from 35mm to 259mm. They are located in the channel by rotating through
90° and can be easily moved to the required position where they are built into the masonry bed joint. See tables for wall tie references and fixing centres.

Wall

Tie Lengths/References
Open Cavity Tie Length Ancon SD25
(mm) (mm) Tie Reference
35-59 100 SD25/100
60-84 125 SD25/125
85-109 150 SD25/150
110-134 175 SD25/175
135-159 200 SD25/200
160-184 225 SD25/225
185-209 250 SD25/250
210-234 275 SD25/275
235-259 300 SD25/300

Recommended Wall Tie and Fixing Screw Vertical Centres,


Based on 25/14 Channel at 600mm Horizontal Centres
Tie Type Insulation Type Insulation Thickness Vertical Tie Spacing Vertical Fixing Spacing
(mm) (mm) (mm)
1 Rigid Max 220 300 225
2 Rigid Max 220 450 337.5
3 Rigid Max 220 450 337.5/450*
4 Rigid Max 220 450 337.5/450*
1 ROCKWOOL Rainscreen Duo Slab™ Max 180 300 225
2 ROCKWOOL Rainscreen Duo Slab™ Max 180 450 337.5
3 ROCKWOOL Rainscreen Duo Slab™ Max 180 450 337.5/450*
4 ROCKWOOL Rainscreen Duo Slab™ Max 180 450 337.5/450*
≤ 31m/s
Notes: Centres shown achieve equivalent tie type performances to PD 6697: 2010 6.2.2.5 Table 12 (M2 Mortar).
*337.5mm centres for insulation thicknesses greater than 114mm

Wall Tie Types


Required Wall Application Maximum Building Geographical Location
Tie Type Height (m)

Light duty tie, Suitable for flat sites in towns/cities where basic
Type 4 suitable for box-form 10 wind speed does not exceed 27m/s and altitude
domestic dwellings is not more than 150m above sea level

Basic wall ties, Suitable for flat sites where basic wind speed is
Type 3 suitable for residential and 15 up to 27m/s and altitude is not more than
small commercial buildings 150m above sea level

General purpose tie, Suitable for flat sites where basic wind speed is ≥ 27m/s
Type 2 suitable for residential and 15 up to 31m/s and altitude is not more than
small commercial buildings 150m above sea level

Suitable for most sites.


Heavy duty tie,
However, for relatively small or unusually
Type 1 suitable for Any height Wind Speed Map
shaped buildings in vulnerable areas,
most building types
tie provision should be calculated from BS EN 1991-1-4: 2005
Notes: Refer to PD 6697: 2010 and BS EN 1991-1-4: 2005 for complete information.

Ancon Building Products


President Way, President Park, Sheffield S4 7UR
Tel: +44 (0) 114 275 5224 Email: [email protected]
www.ancon.co.uk

You might also like