Seaplus Catalog 200905vol1
Seaplus Catalog 200905vol1
Seaplus Catalog 200905vol1
kr
Index
Introduction 04Page
Company history 05Page
External fire fighting system 06~07Page
Water mist fire extinguishing system 08~09Page
High expansion foam fire extinguishing system 10Page
Deck foam fire extinguishing system 11Page
High pressure CO2 fire extinguishing system 12Page
Low pressure CO2 fire extinguishing system 13Page
Dry chemical powder fire extinguishing system 14Page
Automatic sprinkler fire extinguishing system 15Page
Fire detection & alarm system 16Page
Loose fire fighting equipment 17Page
Quality certification 18Page
Total fire test shop 19Page
World wide a/s network 20~21Page
Plant project team 22~23Page
Go with SEAPLUS f o r your safety of fire extinguishing systems, equipments, and others
SEAPLUS for your safety life - 2Page SEAPLUS for your safety life - 3Page
SEAPLUS for your safety life
Introduction
SEAPLUS CO., LTD. is one of leaders and manufacturers for fire fighting
systems & safety equipment in Korea and we have taken our expertise &
experience into the world wide market to establish a reputation for
excellence and customer support.
We are confident that you will find our presentation of interest and assure
you of our competence and desire to realize your contract in away totally
satisfactory to you, our prospective client.
SEAPLUS for your safety life - 4Page SEAPLUS for your safety life - 5Page
SEAPLUS for your safety life
In fire fighting system, the external fire fighting system is to extinguish and suppress
fires against external vessel. It is equipped with fire monitor, fire fighting pump,
electric motor, portable controller and fire monitor and so on. Fire fighting pump can Capacity
be driven by transmission power from driven-engine or dedicated motor. Model Actuating Method Remark
L/min m3/h
According to mounting location of fire monitor, there are sliding tower, folding tower FE-65 500 ~ 1,500 30 ~ 90 Electric
and platform on wheel house. FE-80 1,500 ~ 3,000 90 ~ 180 Electric
Tower's characteristic is to be folded and storaged in a low and compact size. It FE-100 3,000 ~ 5,000 180 ~ 300 Electric
FE-125 5,000 ~ 8,000 300 ~ 480 Electric
would significant facilitate handling on fire suppression and extinguishing using dual
FE-150 8,000 ~ 11,333 480 ~ 680 Electric
monitor of foam liquid and dry powder. FE-200 Electric
FE-200D Electric Double Gun
SFE-200 Electric
11,333 ~ 20,000 680 ~ 1,200
SFE-200S Electric
SFE-200D Electric Double Gun
SFE-200DS Electric Double Gun
External Fire Fighting System FEH-200
FEH-200D
11,333 ~ 25,000 680 ~ 1,500
Electro-Hydraulic
Electro-Hydraulic Double Gun
FEH-250 25,000 ~ 40,000 1,500 ~ 2,400 Electro-Hydraulic
FEH-300 40,000 ~ 60,000 2,400 ~ 3,600 Electro-Hydraulic
1) Range : measured horizontally from the monitor outlet to the mean impact area.
2) Height : minimum height of the trajectory of water monitor jet measured vertically from sea level assuming a mean impact area
located at a horizontal distance not less than 70m from the nearest part of the fire fighting vessel.
3) Fuel oil capacity is to include provisions for continuous operation of all monitors in addition to the total capacity
of the vessel's fuel oil tanks required for continuous fire fighting operation. See also 5-9-2/5.
Sliding Tower
SEAPLUS for your safety life - 6Page SEAPLUS for your safety life - 7Page
SEAPLUS for your safety life
Using spraying water in all fires, the water mist system is to suppress and fight all fires in Local Application System
protected areas. In this fire extinguishing system, water is sprayed in high or low pressure
to make small water droplets. Using water droplets, vaporization effect gets increased as Model : SPF-1
much as surface area expansion. Water mist is sprayed into flame so that to promote Working K-Factor Installation (m)
Pressure (bar) (Flow rate)
Projection
vaporization and decrease in oxygen concentration as suffocation. Extinguishing effect Spacing Min. Height Max. Height
becomes increased by cooling. The system has two types of local fire fighting system and 50 ~ 60 1.5 (10.6~11.6LPM) 1.5 0.6 3.0 Vertical Downward
total fire fighting system. Especially, in case of local application, it is designed and
90 ~ 100 1.5 (14.2~15.0LPM) 2.5 3.0 8.0 Vertical Downward
installed to cover main engine, aux. engine, boiler, incinerator and purifiers as protected
area respectively. The arrangements of nozzle will be provided according to capacity of
nozzle in relevant protected area. In case UMA, after fire happens, using fire alarm
Model : HSN-510
system by detecting fire automatically, water mist pump shall be runned. And water is
Working K-Factor Installation (m)
discharged into fire area through nozzle to extinguish it. During spraying water, audible Projection
Pressure (bar) (Flow rate) Spacing Min. Height Max. Height
and visible alarms are provided in the protected space.
40 ~ 90 1.65 (10.6~44LPM) 4.0 0.6 3.0 Vertical Downward
SEAPLUS for your safety life - 8Page SEAPLUS for your safety life -9Page
for your safety life
SEAPLUS
High Expansion Foam Fire extinguishing system Deck Foam Fire extinguishing system
High expansion foam system is used as alternative system of Halon extinguishing system. Foam system for the protection of chemical and oil tank decks or heli-decks in accordance with class
As halon replacement being phased out due to environmental reasons, high expansion foam system is good requirements and IBC code. Calculated and designed in accordance with international regulations.
replacement. It is also excellent alternative system of CO2 and sprinkler systems. High expansion foam system is The foam monitors may be delivered as manually operated (electric or hydraulic type).
suitable for installation in engine room together with adjacent spaces as local and /or total flooding. The system is
manually operated but may be supplied upon request with remote operation.
High expansion foam system has been extensively full scale tested for fires in machinery spaces,
class 1, 2&3, following IMO guidelines. High expansion foam system
extinguishes fires with a combination of water and foam. Foam fills all
the voids and seals the fire from the air supply, and steam absorbs
heat energy when water is vaporized. An inert atmosphere is created
and the fire is extinguished. When a fire occurs, fire fighting can
immediately begin by the user of high expansion foam system and there
is a further advantage of reduced damage due to the cooling effect
created by the water and the foam on surfaces.
When installing high expansion foam system there is no need for large air
ducts or unnatural hull opening to produce foam. simplified piping system and low
weight generators in combination with seaplus traditionally and well proven foam
central unit makes the whole system easy to install. Foam Tank Unit Balanced Pressure mixer
Foam Generator
Foam Proportioner
Max. Water Flow Connection Size
Model Rate (LPM) Water Side Foam Side
50F - 100W 3,000 JIS10K-100A JIS10K-50A
50F - 150W 6,000 JIS10K-150A JIS10K-50A
80F - 200W 13,000 JIS10K-200A JIS10K-80A
80F - 250W 20,000 JIS10K-250A JIS10K-80A
Foam Monitor
Model Capacity (LPM) Connection Size
FM - 65 500 ~ 1,500 JIS10K-65A
FM - 80 1,500 ~ 3,000 JIS10K-80A
Foam Hose Box
FM - 100 3,000 ~ 5,000 JIS10K-100A
Certification Proportioner
FM - 125 5,000 ~ 8,000 JIS10K-125A
SPECIFICATION
1) High Expansion Foam Concentrate : Meteor P +, Skum Foam Monitor
2) Mixing Ratio : 2% (Foam Concentrate) + 98% (Water)
3) High Expansion Foam Generator
SEAPLUS for your safety life - 10Page SEAPLUS for your safety life - 11Page
for your safety life
SEAPLUS
High Pressure CO2 Fire extinguishing system Low Pressure CO2 Fire extinguishing system
Carbon Dioxide(CO2) Gas, the fastest and most efficient extinguishing agent against fires in protected spaces, The required quantity of CO2 gas is stored in one or two large tank. The tank unit is furnished with its own
suffocates the fire within designated time and minimize the damage in protected spaces. refrigeration machinery to keep the temperature and also to adjust the pressure at the correct level.
The Fire Extinguishing System extinguishes the fire by means of CO2 gas. The system consists essentially of CO2 The system is designed and installed so that CO2 gas can be discharged into relevant protected area using valve
cylinders, main isolating valve(s), manifold, CO2 nozzles in compartment protected space, and pipe lines connecting control cabinet. At that moment, the required quantity of CO2 gas is adjusted by timer which is installed at relevant
these main parts. The system is to be designed by the required discharging time, CO2 cylinders quantity and which are valve control cabinet.
stored in a independent CO2 room. For further security in ship's cargo holds, a smoke detection system can be
combined with the CO2 system. CO2 gas, the fastest and most efficient extinguishing agent against fires in protected
spaces, suffocates the fire within designated time and minimize the damage in protected spaces.
Cylinder Valve
SEAPLUS for your safety life - 12Page SEAPLUS for your safety life - 13Page
for your safety life
SEAPLUS
Dry Chemical Powder Fire extinguishing system Automatic Sprinkler Fire extinguishing system
The SEAPLUS dry powder system is designed specifically for marine application so that This system is installed in accommodation spaces and other service on the vessels such as passenger ships and car
can be met with SOLAS requirements for LPG and LNG tankers. ferries. The sprinkler system is the most effective at its early stage in extinguishing fire.
Statistics estimates that about 70% of all fires has been extinguishing by less than three sprinkler heads.
Operation of sprinkler-system
Immediately after fire breaks out in a protected area, the intense heat rises rapidly under ceiling zone.
As soon as the ambient temperature has reached the set release temperature, the glass bulb bursts and the sprinkler
is activated. The sprinkler pressure tank contains fresh water, which being discharged into protected area, at a
constant pressure level. When sprinkler nozzles are actuated,
the sprinkler system is activated resulting in a pressure drop
in the sprinkler storage tank.
Water supply is provided with adequate pressure by
Dry Chemical Powder Gun Pneumatic Control Cabinet dedicated pump set which is arranged to start automatically
when the pressure falls down below set point of the pump's
start-up relay. The sea ensures an inexhaustible supply as fire
extinguishing agents, posing no threat to passenger and
crew. For safety reasons, the sprinkler pumps can be operated
form the ship's main and emergency switchboard.
Sprinkler Heads
Model Flow Rate (kg/sec) Shooting Length (m)
10 10
16 18
Monitor
20 23 Sprinkler Central
25 30 Panel
Hand Hose Gun 3.5 5 ~ 10 Nozzle Escutcheons
SEAPLUS for your safety life - 14Page SEAPLUS for your safety life - 15Page
SEAPLUS for your safety life
Loose Fire Fighting Equipment
Fire Man’s Outfit Equipments
The fire detection and alarm system consists of fire detectors, manual call point, control
panel, repeater and alarm device and so on.
Upon the receipt of fire and fault signals, fire alarm system shall send relevant signals to
alarm monitoring, alarm device and VDR with audible and visible alarm as well as
indicate fire and fault signals on LCD of fire alarm panel with audible alarm.
Fire detection Alarm system Fire Suit Air Breathing Apparatus Fire Axe With Beit and Life Line Safety Lamp
SEAPLUS for your safety life - 16Page SEAPLUS for your safety life - 17Page
SEAPLUS for your safety life
Quality Certification
Scales
Specification IMO Circ.668 CLASS III (Above 3,000 m3 for large ship)
Length 35 m
Breadth 11 m
Height 12 m
Volume 3,750 m3
Material Anti-Fire Block & Anti-Fire Foam
Major Zone Division Total Fire Test Area : Machinery Area / Control & Monitoring Room
What Fi-Fi System can test ? What Kind of fire can test ?
CO2 System Oil Spray Fire High Pressure (150 bar)
Low Expansion Foam System Low Pressure (7 bar)
High Expansion Foam System Engine Mock-Up
Dry Chemical Powder System Pool Fire
Water Mist System Class A Fire
Water Spray System Cabin, Corridor & Public Space Fire (Future)
Smoke Sampling System
Fire Detection System
Sprinkler System
Portable Extinguisher
Other Water Based Fi-Fi System
SEAPLUS for your safety life - 18Page SEAPLUS for your safety life - 19Page
Go with SEAPLUS f o r your safety of fire extinguishinh systems, eguipments, and others
SEAPLUS for your safety life - 20Page SEAPLUS for your safety life - 21Page
SEAPLUS Plant Project Team
Seaplus plant project team plans, designs, manufactures and supplies a full range of proprietary products for dust
suppression, return belt washing and water spray system. Plusgun dust suppression system consists of the PLC based
control system and a shooting gun which spray water on the ground uniformly. Plus dust suppression system is
focused on developing intelligent solutions for the flying ash at raw material storage area like as coal, coke and scrap
iron etc or inside chute and skirt in transfer tower. Return belt washing system for protect to stack a raw material on
DESIGN & CONSTRUCTION for FIRE FIGHTING SYSTEM of PLANT PROJECT the floor in gallery or girder is applied to bulk material handling system.
Seaplus’s Plant project team consists of specialists for mechanics, electronics, thermodynamics
and fluid mechanics based fire fighting system. PLUS GUN DUST SUPPRESSION SYSTEM PLC BASED CONTROL SYSTEM
Plant project team has delivered to all Korean thermal power plant a fire fighting system & fire
alarm and fire detection system for parts of bulk material handling system and boiler system after
2003 year. We have licenses for fire fighting design and construction approved by Korean
government.
We accepted an order for the fire fighting system of Cuba DPP project and the service gas supply
system of Bahrain IWPP project recently.
SEAPLUS for your safety life -22Page SEAPLUS for your safety life - 23Page