0% found this document useful (0 votes)
162 views4 pages

Type Test Approvals: Powering The Region

This document provides a table listing 15 types of cables and their certifying agencies. It includes low voltage power cables, control cables, wiring cables, medium voltage power cables, pilot cables, instrumentation cables, fire resistant cables, and essential safety circuit cables. The certifying agencies include Lloyd's Register, KEMA in the Netherlands, Warrington Fire Research, CPRI in India, and BRE in the UK.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
162 views4 pages

Type Test Approvals: Powering The Region

This document provides a table listing 15 types of cables and their certifying agencies. It includes low voltage power cables, control cables, wiring cables, medium voltage power cables, pilot cables, instrumentation cables, fire resistant cables, and essential safety circuit cables. The certifying agencies include Lloyd's Register, KEMA in the Netherlands, Warrington Fire Research, CPRI in India, and BRE in the UK.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Powering the Region

TYPE TEST APPROVALS


Sr. No. Product Description Certifying Agency

1 Low voltage XLPE insulated Power cables

Material of conductor : Copper


BS:5467 & IEC:60502-1
1 core (50 mm² to 1000 mm²) LLOYD's Register

2, 3 and 4 core (1.5 mm² to 400 mm²) & 5C


upto70mm²; 1.5-4mm² upto 48cores LLOYD's Register

Low voltage PVC insulated Control &


2
Auxiliary cables

BS:6346 (for PVC) & IEC:60502-1


2, 3 and 4 core (4, 6 and 10 mm²) LLOYD's Register

2 to 48 core (1.5 and 2.5 mm²) LLOYD's Register

3 PVC insulated Wiring cables

BS:6004
Material of conductor : Copper
450/750 V 1 core (1.5 to 630 mm²) LLOYD's Register

300/500 V 1, 2, 3, 4 & 5 core (1.5 to 35 mm²) LLOYD's Register

300/500 V Flat Twin (1.5 to 16 mm²) LLOYD's Register

450/750 V 1 core (1.5 to 35 mm²) - Type TI-3 (Table


11 as per BS:6004) LLOYD's Register

Low voltage XLPE insulated Power, Control


4 & Auxiliary cables for Low Smoke and Fume
(LSZH) Cable systems

BS:6724
600/1000 V
Material of conductor : Copper
1 core (50 mm² to 1000 mm²) ; 2, 3 & 4 core (1.5 LLOYD's Register
mm² to 400 mm²) ; 5 core (1.5 mm² to 70 mm²) ; 7 to
48 core (1.5, 2.5 & 4 mm²)
Powering the Region

Low voltage XL-LSZH Insulated Wiring cables


5 for Low Smoke and Zero Halogen (LSZH)
Cable systems

BS:7211
Material of conductor : Copper

1 core 4 mm² Blue (tested to IEC:60332-1) Warrington Fire Research

1 core 4 mm² Yellow (tested to IEC:60332-1) Warrington Fire Research

1 core 2.5 mm² Blue (tested to IEC:60332-1) Warrington Fire Research

1 core 2.5 mm² Black (tested to IEC:60332-1) Warrington Fire Research

1 core 4 mm² Green/Yellow (tested to IEC:60332-1) Warrington Fire Research

1 core 6 mm² Green/Yellow (tested to IEC:60332-1) Warrington Fire Research

Lead Sheathed Low voltage XLPE insulated


6 Power, Control & Auxiliary cables for Oil,
Gas and Petro/Chemical Industries

BS:5467 & IEC:60502-1 & EEMUA No. 133


Material of conductor : Copper
1 core (50 mm² to 1000 mm²) ; 2, 3 & 4 core (1.5 LLOYD's Register
mm² to 400 mm²) ; 5 core (1.5 mm² to 70 mm²) ; 7 to
48 core (1.5, 2.5 & 4 mm²)

Lead Sheathed Low voltage PVC insulated


7 Power, Control & Auxiliary cables for Oil,
Gas and Petro/Chemical Industries

BS:6346 & IEC:60502-1 & EEMUA No. 133


Material of conductor : Copper
2, 3 & 4 core (1.5 mm² to 400 mm²) ; 5 core (1.5 LLOYD's Register
mm² to 70 mm²) ; 7 to 48 core (1.5, 2.5 & 4 mm²)

Medium voltage XLPE insulated Power


8
cables

3 x 240 AL/XLPE/CUTAPE/PVC/GSWA/PE 6/10 kV KEMA, The Netherlands.


to IEC:60502-2

1 x 240 CU/XLPE/CUWIRES/PVC 18/30 kV to KEMA, The Netherlands.


IEC:60502-2

1 x 800 AL/XLPE/LEAD/PE 18/30 kV to IEC:60502-2 KEMA, The Netherlands.


& MEW specification TND-068
Powering the Region

3 x 300 CU/XLPE/CUTAPE/PVC/GSWA/PVC 6/10 KEMA, The Netherlands.


kV to IEC:60502-2

3 x 240 CU/XLPE/CUTAPE+Interstitial KEMA, The Netherlands.


Conductors/PE/GSTA/PE 18/30 kV to IEC:60502-2
& ADWEA Contract Specification

Earth fault current withstand capability of Metallic CPRI, India


screen (Interstitial Copper conductors + Copper
Tape) of 3 x 240 CU/XLPE/CUTAPE+Interstitial
Conductors/PE/GSTA/PE 18/30 kV cable to
IEC:60502-2 & ADWEA Contract Specification

Abrasion, Penetration & Saline Bath test on PE LLOYD's Register


sheath as per IEC:229/1982 (Cable :- 3 x 240 33
kV ADWEA).

3 x 240 CU/XLPE/CUTAPE+Interstitial KEMA, The Netherlands.


Conductors/PVC/GSTA/PVC 6.35/11 kV to
IEC:60502-2 & ADWEA/11kV-3C/2000 Specification

1 x 630 CU/XLPE/CUTAPE/PVC/AWA/PVC 19/33 KEMA, The Netherlands.


kV to IEC:60502-2 & ADWEA/33kV-SC/2000
Specification

1 x 500 CU/XLPE/CUWIRES/PVC 19/33 kV to KEMA, The Netherlands.


IEC:60502-2 & FEWA Specification No. 6.1

1 x 630 CU/XLPE/LEAD/PVC 19/33 kV to KEMA, The Netherlands.


IEC:60502-2 & SAMSUNG Specification no. 1718-
4472

3x400, CU/XLPE/CTS+CWS/GSWA/PE, 19/33 KV KEMA, The Netherlands.


to DEWA spec. 1.5.1.3.3.01-Rev 01 & IEC 60502-2

1x800, CU/XLPE/CWS/PE, 6.35/11 KV to DEWA KEMA, The Netherlands.


spec. 1.5.1.3.4.01-Rev 5 & IEC 60502-2

9 19 core Pilot Cable

MEW, OMAN STANDARD OES2 (Specification CPRI, India


No. UG4)

PE Insulated Multipair Instrumentation


10
Cable

BS 5308 Part 1 TYPE:1, TYPE:2 AND TYPE: 3 LLOYD'S Register

300/500V, 1,2,5,10,15,20,30 and 50 Pairs; X


Sectional Area=0.5,1 and 1.5 mm²
Powering the Region

11 600/1000V Armoured Fire Resistant Cable

BS 7846 :2000 Category F2 LLOYD'S Register

600/1000V. 2,3,4,5&7-48(AUX) Cores; X Sectional


Area=1.5-400mm²

BS 7846 : 2000 Category F2 & F3 BRE, UK

600/1000V 4X240mm²

600/1000 V 3X2.5 mm²

600/1000V 4X50mm²

600/1000V 4X50mm² (incorporating amendments


nos. 1 & 2) clause 17.4.3 (category F2)

600/1000V 5X1.5mm² (incorporating amendments


nos. 1 & 2) clause 17.4.4 (category F3)

600/1000V 5X1.5mm² (incorporating amendments


nos. 1 & 2) clause 17.4.3 (category F2)
4x400 sqmm cable to BSEN 50266-2-4:2001

2x50 sqmm cable to BSEN 50266-2-4:2001

76/132 kV 1 CX800mm² Cu/XLPE TO


12 IEC60840, BS:7912 &ADWEA SPECN S- KEMA, The Netherlands.
CAB-132-HDPE-1( Rev. 0-2002)

1CX240mm² 12/20kV Cu/XLPE TO IEC60502-


13 KEMA, The Netherlands.
2 AND BS:7835

BS 7629 Cables - Wiring cable for essential


14
safety circuits

450/750 V 1 core 1.5 to 10 mm² BRE, UK

15 Water treeing susceptibility tests KEMA, The Netherlands