Peripheral Launder Hydraulics

This document provides sizing calculations for a peripheral launder and outlet box culvert system. It details that the total stormwater pump station flow is 25 cubic meters per second. The peripheral launder is sized to carry 12.5 cubic meters per second from each side, with a minimum width of 6 meters. The outlet box culvert is sized to carry 25 cubic meters per second from each side, with a channel width of 18 meters. Hydraulic calculations like depth, area, velocity, and slope are provided for both the peripheral launder and outlet box culvert.

Uploaded by

ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
279 views2 pages

Peripheral Launder Hydraulics

This document provides sizing calculations for a peripheral launder and outlet box culvert system. It details that the total stormwater pump station flow is 25 cubic meters per second. The peripheral launder is sized to carry 12.5 cubic meters per second from each side, with a minimum width of 6 meters. The outlet box culvert is sized to carry 25 cubic meters per second from each side, with a channel width of 18 meters. Hydraulic calculations like depth, area, velocity, and slope are provided for both the peripheral launder and outlet box culvert.

Uploaded by

ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Hydraulics of Peripheral Launder and Outlet Box culvert

Sl. No. Description Value Units


1 Total flow through Storm water Pump station 25 m3/sec
2 Over flow weir/Bypass Gate sizing
3 Wdth of weir 5 m
4 flow through each weir 6.25 m3/sec
5 Ce 0.846
6
7 h 0.909 m
8 909.4 mm
Overflow/Bypass Gates considerd 5.0m (W) x 1.4m(D), 2 nos.
9 on each side of Peripheral
Launder
10 Peripheral Launder sizing:
11 minimum channel width considered 6 m
12 n, Manning's coefficient 0.015
13 depth of flow 0.895 m
14 flow area 5.372 m2
wetted perimeter 7.791 m
15

hydraulic radius 0.690 m


16

17 Slope 0.002
velocity 2.327 m/sec
18

flow from each side of launder 12.500 m3/sec


19

20 Maximum channel width 8 m


21 n, Manning's coefficient 0.015
22 depth of flow 0.725 m
23 flow area 5.803 m2
24 wetted perimeter 9.451 m

Page 1 of 2
25 hydraulic radius 0.614 m
Slope 0.002
26

velocity 2.154 m/sec


27

28 flow from each side of launder 12.500 m3/sec


29 Outlet Box culvert sizing:
30 channel width considered 18 m
31 n, Manning's coefficient 0.015
32 depth of flow 0.510 m
33 flow area 9.185 m2
34 wetted perimeter 19.021 m
35 hydraulic radius 0.483 m
36 Slope 0.0044
37 velocity 2.722 m/sec
38 flow from each side of launder 25.00 m3/sec