FUNDAMENTALS OF
POST-INSTALLED
REBAR DESIGN USING
QUALIFIED ADHESIVE
ANCHOR SYSTEMS
Abraham Chapa
Field Engineer
1
Fundamentals of Post-installed Reinforcing Bar
Design Using Qualified Adhesive Anchor Systems
Abraham Chapa
Hilti Field Engineer
AGENDA
2
ADHESIVE ANCHORS ARE USED IN A VARIETY OF
CONSTRUCTION APPLICATIONS
Rebar doweling
Rebar
Adhesive
Threaded Rod
+ Torque Controlled
Threaded Rod
Internally
Threaded Insert
3
THESE TWO APPLICATIONS ARE GOVERNED BY TWO
DESIGN THEORIES: ANCHOR AND REBAR THEORY
Anchor Theory Rebar Theory
Adhesive + Rod Adhesive + Rebar
+ +
For tension loads, splitting of the concrete is typically not relevant due to the
limitations placed on edge distance, concrete thickness, and anchor spacing.
4
A CLOSER LOOK AT REBAR APPLICATIONS…
Applications involving extension of existing construction with new elements using Hilti HIT-RE 500 V3 and Hilti HIT-HY 200
5
POST-INSTALLED REINFORCING BARS HAVE A FEW
FUNDAMENTAL DISTINCTIONS COMPARED TO ANCHORS
Post-installed rebar can be characterized as follows:
• Embedded in adhesive in a hole drilled into existing
structure on one side of the interface and cast into new
on the other side.
• Often installed with minimal edge distance resulting in
splitting as the failure mode.
• Typically not designed to resist direct shear loading in
the manner of an anchor bolt.
• Generally embedded as required to “develop” their yield
strength using the development splice length provisions
of the code.
6
AGENDA
Extensive
investigations begin…
7
TENSION TESTS COMPARE THE PERFORMANCE OF
POST-INSTALLED AND CAST-IN REINFORCING BARS
1 Spieth, H., “Structural Behavior and Design of Bonded Reinforcing Bars,” doctoral thesis, University of Stuttgart
1 Spieth, H., “Structural Behavior and Design of Bonded Reinforcing Bars,” doctoral thesis, University of Stuttgart
Splitting is the failure mode for slender elements with small concrete cover.
8
HOW ARE ADHESIVE SYSTEMS QUALIFIED TO VERIFY
“SAME AS CAST-IN” REINFORCING BAR PERFORMANCE?
ICC-ES AC308 lists the full range of tests required to qualify adhesive anchor systems for
post-installed reinforcing bar applications.
• Systems that may be appropriate for anchoring applications will not necessarily fulfill the
requirements for safe and reliable reinforcing bar installations.
AC308 Table 3.8 details the test program for evaluation and qualification.
Systems that may be appropriate for anchoring applications will not necessarily
fulfill the requirements for safe and reliable reinforcing bar installations.
9
ICC-ES AC308 TEST FOR BOND / SPLITTING BEHAVIOR
10
AGENDA
EASY – look for an Evaluation Service Report (ESR) for that product.
What is an ESR?
• Product specific ESRs, which verifies code compliance*, are published by ICC-ES
based on testing performed in accordance with appropriate acceptance criteria (AC).
*ESRs do not specifically address Canadian codes but the qualification testing requirements are essentially identical in the US and Canada
11
ICC-ES EVALUATION REPORT CONFIRMS THAT THE SYSTEM
SELECTED IS APPROPRIATE FOR USE
A CSI Division Number
B Report Holder
C Evaluation Subject
1.0 Evaluation Scope
2.0 Uses
3.0 Description
4.0 Installation
5.0 Conditions of Use
6.0 Evidence Submitted
7.0 Identification
12
SIZE AND REQUIRED BOND LENGTH GUIDE THE TYPE OF
ADHESIVE USED
13
SLOW CURE ADHESIVE ANCHORING SYSTEM
HILTI HIT-RE 500 V3 SAFESET ADHESIVE
Cracked Uncracked
Concrete Concrete
14
HILTI ADHESIVE ANCHORS ARE QUALIFIED FOR USE WITH
POST-INSTALLED REINFORCING BARS PER CHAPTER 12
AGENDA
15
INSTALLATION AND LOCATION OF POST-INSTALLED
REINFORCING BARS IS CRITICAL TO PERFORMANCE
1 2
Using a hand-held scanner to locate and map Roughening a concrete surface with a combihammer
existing reinforcing prior to drilling. and bushing tool
16
SELECTING THE PROPER DRILLING METHOD HELP TO
ENSURE PROPER CONCRETE COVER
3
17
THE BOND BETWEEN THE ADHESIVE AND CONCRETE IS
DIRECTLY INFLUENCED BY THE HOLE CLEANING.
5
Note: Shown for illustrative purposes only. Reference complete manufacturer installation instructions before installing your specific anchor.
18
PROPER HOLE CLEANING IS ESSENTIAL: AVAILABLE DUST
CONTROL SYSTEMS SIMPLIFY THE PROCESS
5
or
• Can the adhesive be injected and the bar installed • Available battery dispensers simplify the injection
within the gel time of the adhesive? of the adhesive into the hole.
• Is the appropriate injection equipment available, • Piston plug systems provide positive feedback to
including all necessary accessories, to ensure the operator for controlling the injection process
correct dispensing and mixing? and dramatically improves injection quality and
• Is the adhesive suitable for the concrete temp, efficiency.
moisture conditions, hole orientation and drilling
method?
• What effort is required to inject the adhesive?
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 38
19
HOLES THAT CLEAN THEMSELVES
SafeSet Post-Installed Rebar System
MANUFACTURER TRAINING - US
Manufacturer Adhesive
ACI & CRSI
Anchor Installer Training Adhesive Anchor Installer
Certification program
Hilti can help the contractor understand correct installation steps and prepare for the
Adhesive Anchor Installer Certification or manufacturer advanced training.
20
MANUFACTURER TRAINING - CANADA
Manufacturer Adhesive
ACI & CRSI or Equal
Anchor Installer Training Adhesive Anchor Installer
Certification program
Hilti can help the contractor understand correct installation steps and prepare for the
Adhesive Anchor Installer Certification or manufacturer advanced training.
HIT-RE 500 V3
SafeSet
Slow Cure Epoxy
21
AGENDA
•
b Bar type and size
•
d Hole diameters and drilling method(s)
•
g Installer training/certification requirements
•
h Inspection/proof loading requirements
22
CONNECTION DETAIL EXAMPLE:
DOWELS AT NEW SHOTCRETE WALL
a
Hilti HIT-RE 500 V3 SafeSet
b
f
c a
HIT-RE 500 V3 SafeSet
23
SPECIFYING WITH HILTI HIT-RE 500 V3 AND HIT-HY 200
SAFESET SYSTEMS IN THE GENERAL NOTES
a d
AGENDA
24
REBAR DESIGN CENTER
• Web-based software
• Quick reference guide for
• Design post-installed rebar
– Non-contact lap splices
connections per ACI 318
– Shear dowels
– Starter bars
• https://profisrebar.hilti.com
• Design examples
25
A NEW PUBLICATION IS AVAILABLE WHICH PROVIDES FURTHER
DETAILS INTO POST-INSTALLED REINFORCING BAR DESIGN
AGENDA
26
SUMMARY
• Acceptance criteria (AC308) now qualifies adhesive • Cast-in bars and qualified post-installed reinforcing
anchor systems for post-installed reinforcing bar bars behave the same with small cover (~2”).
applications.
• Qualified adhesive anchor systems can be
• The suitability of an adhesive system for post- designed like a cast-in reinforcing bar using ACI
installed reinforcing bar applications is dependent 318, Chapter 12 or CSA A23.3 Chapter 12.
on many factors.
• Installation and location of post-installed reinforcing
• Systems that may be appropriate for anchoring bars is critical to performance and should be
applications will not necessarily fulfill the appropriately detailed and specified.
requirements for safe and reliable reinforcing bar
installations.
• Assumption of reinforcing bar development is the
most fundamental distinction separating post-
installed rebar from adhesive anchors.
ADDITIONAL RESOURCES:
ICC-Evaluation Service
• www.icc-es.org
Hilti Online
• www.hilti.com or www.hilti.ca
Technical manuals:
• Hilti North America Post-Installed Reinforcing Bar Guide
• Hilti North America Post-Installed Reinforcing Bar Supplement
Research papers:
“Recommended Procedures for Development and Splicing of Postinstalled Bonded
Reinforcing Bars in Concrete Structures,” ACI Structural Journal, Vol. 110, No. 3, pp.
437-447, Charney, F., Pal, K., and Silva, J. (2013).
“Structural Behavior and Design of Bonded Reinforcing Bars”, doctoral thesis,
University of Stuttgart (in German), Spieth, H. (2002).
27
ASK HILTI
Hilti engineering community
and On-Demand Education
platform
55
28
YOUR ON-DEMAND EDUCATION ENGINEERING PLATFORM
Upload all your certs (not just Hilti’s) to have them all in one
place!
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 57
ENGINEERING COMMUNITY
29
UPCOMING NCSEA-ACCREDITED WEBINAR
QUESTIONS?
Hilti North America
(877) 749-6337 – Technical Support Team
[email protected]
www.us.hilti.com/engineering
Abraham Chapa
Field Engineer
Dallas-Forth Worth, TX
Dick Morgan, PE
PROFIS Software and Literature Manager
Plano, TX
30
-Conclusion of Hilti webinar-
Individual participants:
Individual participants will receive a certificate to the email provided during registration.
Certificates will be distributed within a week of the event.
Group participants:
Attendees participating in a group go to www.us.hilti.com/webinar-group-sign-in to
enter the team’s information. Certificates will be distributed within a week of the event.
Certificates:
One (1.0) hour credit is approved by NCSEA.
31