Jack E4
Jack E4
Jack E4
2.Standby mode
The left digital display shows “P” on standby mode, the right digital display
shows the current needle position, picture 1 shows the upper and lower needle
position
3.Speed adjust
The panel shows “P”, short press or to adjust speed up 100RPM
and down 100RPM, long-press ( ) speed rapidly up (down),parameters
are autosaved.
第 1页
5.Parameter settings
In the standby interface press and for 3 seconds, enter the interface of
parameter settings. The first tube display F, the second tube doesn’t display.(it called F
interface, one of the setting interfaces) , showed as picture 2
F interface
after entering the parameter setting interface press to change the parameter
number, press ,will show the corresponding parameter values, then press
again to change the parameter values, after changing it, press to save it, on the
panel will show OK (showed in the picture 3), then return to the interface of
parameter number, if the parameter doesn’t change, it will directly return to the
interface of parameter number. In the parameter setting interface motor will back to
standby interface. The serial number on will be recycling on the F interface as
followed:
Serial Factory
parameter range noted
NO. settings
LED light 0:off 1.level 1 2:level 2 3:level
k 0-3 2
adjustment 3
Limited sewing
L 05 - 55 50 Decline by 500rpm every time
speed
Switch of needle
M 0-1 1 0:off 1:on
position
H Dormancy time 0-6 3 unit:10min 0:off
v Speed display 0-1 0 0:off 1:on
w Power display 1-99 1:≤10W,99:≥990W
Undervoltage
r 0、14、15 15 0:off 14:144VAC 15:154VAC
alarm value
Overvoltage alarm
Y 0、26、27 26 0:off 26:264VAC 27:274VAC
value
Can’t be
J Serial NO query Showed on the machine
set
picture 3 oK
第 2页
6.Power Display
Enter into “system parameter setting mode”,press and change to“w”
parameter mode,then press will real-time display the current power consumption
of machine。When the machine is not working ,press will return “w” parameter
mode。
8.Durability test
Press for 3s enter durability test, during onely the first digital tube show “T” .
Durability parameters are described as follows. If the motor is running when setting
the durability parameter, it exits to the standby interface, In the setting of durability
parameters if the motor is running out to the standby interface in the durability of the
short button after the machine will enter he durable mode of operation in the short
duration of the short button to exit the normal sewing mode.
Default
Number Function parameter Range Parameter description
value
Working time 1-9 3 unit:s
第 3页
10.Digital tube display Introduction
Number Part:
Number 0 1 2 3 4 5 6 7 8 9
Digital tube
display
English
K L M N O P Q R S T
alphabet
Digital tube
display
English
U V W X Y Z
alphabet
Digital tube
display
第 5页