Semi Addressable
Full Addressable
ADDRESSABLE FIRE ALARM CONTROL PANEL
FEATURES
English LCD Screen (240 x 128 or 240 character).
LCD backlight energy-saving protection function.
Two-wire circuits for supper long transmission distance
(up to 1,5 km between the control panel and modules).
The data memory device can store up to 2000 historical records permanently
(the device in graphic system can be expandable up to 20 million records).
Composed voice alarm function (broadcost)in human voice to operators).
Voice guidance function (while operating)
Abnormal temperature protection function (I/O modules over loading).
5LCs, IDCs are equipped with insulation for false inspection function.
Protection against lightning surge. HOOSEKI Fire Alarm
I/O modules miswiring protection to accessories are available. Control Panel
I/O modules are equipped with segment isolation function.
A table to review all I/O modules statuses is available for casier operation.
Addresses and interlocks can be display on the LCD screen.
Weekly automatic check function.
Repeat alarm function.
Two stage alarm delay function
Standby battery with power saving function
Build in-printer
Addressas
/Loops 256/1L 768/3L 1024/4L 1208/5L 1536/6L 1792/7L 2048/8L
SPECIFICATIONS
ITEM Specifications
Cabinet Material Powder coating steel (optional Flame retardant ABS enclosure available
up to 256/1L only)
CONVENTIONAL FIRE ALARM CONTROL PANEL
FEATURES
Two-Stage alarm delay function :
At the first stage, when the detector sends the signal for the first time, the control
panel will automatically reset the signal and enter the second stage for standby
after 8 seconds.
At the second stage, if there is another signal sent by the detectors within 9-40
seconds, the control panel will triggered the fire alarm, else reset the alarm signal.
This will prevent the control panel from sending false alarms.
Standby battery protection :
During power-cut, when the standby battery is under DC 18V it will automatically
stop discharging to extend battery life.
Protection against lighting surge :
Power supply module with protection against lightning surge to avoid device
damage caused by high voltage or power surge.
Quality control :
All interior components of the display module and base boards in the unit are
approved by CE and CNS. All products have to pass strict inspection before
delivery to ensure durability.
Abnormal voltage inspection :
HOOSEKI Fire Alarm
With abnormal voltage display function, the system can indicate high and low voltage.
Control Panel
Modular design :
The system has modular design with inputs/ outputs independet terminal module. If there is a problem on site, users do not have
to remove external wires and can easly replace defective boards improving the efficiency of maintenance and inspection.
Exterior design :
Equipped with zone display panel board. The panel (made of flame retardant plastic) adopt a streamline design for clear
indication of zone’s name, floor, building, properties, etc.
DIMENSIONS (STEEL)
Cabinet Wall-mount
Number
of Loops 5~10L 15L 20L 25~30L 35~40L 45~50L 55~60L 65~70L 75~80L 85~90L 95~100L 105~110L 115~120L
H(mm) 400 495 580 520 580 700 760 840 930 1020 1110 1195 1350
W(mm) 300 300 300 480 480 480 480 480 480 580 580 580 580
D(mm) 120 120 120 180 180 180 180 200 200 200 200 200 200
Interlock
Cabinet Floor-standing 2-in-1 3-in-1 4-in-1 Control Panel
Number 125~130L 135~150L 155~170L 135~260L 265~300L 305~340L 345~450L 455~600L 1L 1L
of Loops
H(mm) 1600 1800 2000 1600 1800 2000 1800 1800 180 250
W(mm) 580 580 580 1160 1160 1160 1740 2320 180 210
D(mm) 260/360 260/360 260/360 260/360 260/360 260/360 260/360 260/360 75 90
SPECIFICATIONS
ITEM Specifications
Model HS-5L, 10L, 15L, 20L, HS-25L, 30L, 40L, 50L (5 Zone - 40 Zone)
AN-5L, 10L, 15L, 20L, 25L, 30L, 40L, 50L (5 Zone - 50 Zone)
Power Source 110V AC 50/60 Hz or 220V AC 50/60 Hz
Standby Battery 24V DC
Charging Voltage Below 26V DC 450mA, trickle charging
Circuit Voltage 24V DC operation voltage, under 10~11V DC 32mA
Rated Impedance Under 50 , Ground Resistance above 2M
Detector Connection No limiitation for Conventional Rate of Rise Heat / Fixed Temperature Heat
Detectors : Up to 30 Photoelectric Smoke Detectors (24V DC 40 A) per zone
E.O.L Resistor 10K
No. of Indicators 1.2 times of the number of zone (LED indicating lamp)
No. of Bells 1.2 times of the number of zone
ADVANTAGES
Rate-of-rise heat detector detects intense fires by Red indication lamp lights when detector is
quickly responding to rapid temperature increases. activated.
Mechanical operating principles ensure the long- High-temperature-enduring plastics and fire-proof
term durability and the least malfunction. material are used to build up the main body of
Self-restoring ensures those elements repeated use. the detector.
High quality components are fitted for greater The base is in common with other detectors made
reliability. in this company for the facilitation of installation.
Coonections are non-polarized to avoid wiring
mistakes.
SPECIFICATION
Model HS-WS19L Ambient Temp. -10 C~+55 C
Type 2 wire Ambient Humidity 0~95%
Voltage Range 12~30V DC Material Fire-proff Plastics
Alarm Current 24V DC 30mA Dimensions 102 (Dia.) x 42 (H)mm
Contact Rating N/A Weight 130g
Polarization Non-polarized Color White
Alarm Temp. Comply to EN54, CNS
+
OPERATION PRINCIPLES
Contacting Point
-
Insulator Leak Hole MOUNTING STATUS
Diaphragm
Heat-Detecting Chamber
DIMENSIONS
Base
Unit: mm 42 83
Body Pitch
90
102 Base
WIRING AND CONNECTION
46
Head
O 90
O 103
FIRE ALARM SYSTEM
Fixed Temperature Heat Detector
ADVANTAGES
Stabilized performance, long-term durability and Red indication lamp lights when detector is activated.
least-malfunction are ensured by employing a High-temperature-enduring plastics are used to build
bimetal mechanism. up the main body which is also nicely shaped.
Self-restoring ensures the elements repeated use. The base is in common with other detectors made
The sensitive part is enclosed to prevent from in this company for the facilitation of installation.
being moistened and contaminated. Connections are non-polarized to avoid wiring
Pure silver contacts ensure the quick response. mistakes.
SPECIFICATION
Main Model HS-WK100L Alarm Temperature Comply to EN54, CNS
o
Type 2 wire Ambient Temperature +70 C
Voltage Range 12~30V DC Ambient Humidity 0~95%
Alarm Current 24V DC 30mA Material Fire-Proof plastics
Polarization Non-polarized Dimensions 101 (Dia.) x 47 (H)mm
Sensitivity : Weight 100gms.
When exposed within an air stream 1 m/sec., 125% Color White
higher than its operating temperature, and at 20 C
of ambient temperature, the detector will sound an
alarm within 90 seconds.
OPERATION
Thermostat Terminal
PRINCIPLES
MOUNTING STATUS
Heat-Detecting Plate
Cap 83
Insulated Pin
Pitch
WIRING AND CONNECTION
46
O 103
FIRE ALARM SYSTEM
Photoelectric Type Smoke Detector HS-136
ISO 9001, Approved
Smoke Detector Model HS-136
Detector Status LED Indicator :-
Normal Status : Green (Bli
Alarm Status : Red
O 100mm
HS-136
SPECIFICATIONS
8 mm
Technical Specifications Smoke Detectors
Normal Rated Voltage 24VDC 56 mm
Operating Voltage 9.6 VDC to 30 VDC 48 mm
Quiescent Current < 60 uA
Alarm Current Typical 20mA
Remote LED Drive Current Output Max. 20mA Smoke
Maximum Air Velocity 7.6 m/s Chamber
Weight 102g (160g with Base DB-6) c/w Insect
Operating Temp. Range -10oC to +50oC Screen
Relative Humidity 95%RH, Non Condesing @40 C
Alarm LED Indication Red ( Continuous )
Normal LED Indication Green ( Blinking )
Ingress Protection IP42 Detector
Material of Body ABS Plastic (To UL94V-0 Flammability Test Standards) Head
Colour of Body White Detector
Standards In Compliance to EN54 Part 7 Base
Terminate the detector wiring as shown below :- Terminal 3 : - Remote LED ‘Out-’ (Cathode)
Terminal 1 :-Zone ‘In’ Terminal 4 : - Remote LED ‘Out-’ (Cathode)
(Interrupted for fault detection Terminal 5 :- Zone ‘In’
upon removal of detector head) Terminal 6 :- Zone ‘Out’
Terminal 2 :-Zone ‘Out’ Terminal 7 :- Remote LED ‘Out+’ (Anode)
(Interrupted for fault detection upon Termonal 8 :- Remote LED ‘Out+’ (Anode)
removal of detector head)
Typical Detector
Termination Diagram
Recommended Wiring :
Colour Coded PVC
Cable, Cross Section
of not less than 1.0mm 2
FIRE ALARM SYSTEM
Photoelectric Type Smoke Detector HS-WT30L
ISO 9001, Approved
DESCRIPTION
The photoelectric type smoke detector is based on the
photoelectric sensing principle to make up.
When fire break out and smoke enters the light- tight
box, the particles of smoke scatter the infrared light,
and this scattered light goes into the receiving element,
thereby emitting an electric current, and while the
electric current is up to the fixed extend, the fire alarm
will be activated. This is an advance scientific device. It
is very quick and accurate to activate the early fire
HS-WT30L warning system. Because of the pretty and compact
styling, it is most suitable for the interior decoration of the
modern buildings.
ADVANTAGES
With the photoelectric sensing principle, this kind The photoelectric type detector ensures repeated
of detectors is activated more quickly, accurately and use and by removing the cover can accomplished
reliably, and there are no false alarm due to maintenance easily.
chemicals, exhaust gas, wind and exterior light. Connection are non-polarized to avoid wiring
With stainless steel net of holes’ diameter 0.5mm mistakes.
preventing from flying insects and dust particles but Universal base is interchangeable with the various
no barrier to smoke inflow. type detectors’ base made in this company, reducing
No harm to man and beast as no radiation source storage and installation costs.
is used.
Because of the compact styling and pretty outlines,
it is most suitable for such modern buildings as
employed in the design of decorative smooth ceilings.
83
WIRING AND CONNECTION
Pitch
Base
Body
46
O 103
FIRE ALARM SYSTEM
Fire Alarm P.B.L Combination Series
Base Manual
Call Point (HS-Base)
DESCRIPTION
This Fire Manual Station can quickly transmit a signal to the fire
receiver terminals or the repeaters while the button under a
transparent protective cover has been pushed at the first finding
of a fire accident. (This signal is beyond the accumulated time
limitation).
There is a light over the button. The light will light up as a signal has been exactly
received by the receiver terminal. There is also a telephone jack for telephone
communication with attendant at the fire receiver terminal.
HS-FP1 Manual Call Point
ADVANTAGES
SPESIFICATIONS 1. Auto-Return by pushing button, no need to disassemble
Model No. HS-FP1 the main body.
Voltage Range 24V DC 2. Response light available to identify the operation completed.
Alarm Current 30 mA
3. Reinforced transparent protective cover is reusable.
Contact Rating 24V DC 100mA
Sub-Function Phone jack; Confirmation LED; 4. All plastics are fire-proof, light, convenient and stylish.
Reset button 5. Outside cord distribution with terminators to ease on work.
Option Base
Material Fire-Proof plastics MOUNTING
Dimensions O 140 (mm)
Weight 150g
Color Red
28 70
SPESIFICATIONS
Model No. HS-FL3
Power Source 24V DC
Alarm Current 12 mA
DESCRIPTION Ambient Temp. -10 C~+55 C
The fire indicating lamp is an equipment to go twinkling, Material Fire-Proof plastics
to show the position of a fire signal device and to be Weight 52g
controlled vby fire receiver terminal or a repeater while
Dimensions O 92 x 58 (H) mm
Color Red
a fire accident accured.
Movement Motor + + + +
Material 3.0 Alloy Alu B B B
Dimensions O 6” (150mm) - - - -
Color Red
FIRE ALARM SYSTEM
Fire Alarm Accesories
FRONT VIEW HS-PBL
SIDE VIEW Fire Alarm Combination
SPESIFICATIONS
Function Communication short circuit isolation
Operating Voltage DC16~36V
Current Consumption DC32V normal 400 A
Reaction time Below 0.3 sec
Ambient Temperature 0 C~50 C Relative Humidity below 95%
Dimension 67 x 100 x 26 mm
Material Fire~proof plastic
Wiring Notes :
Addressable Detector Base’s L+ LC connect
to Convensional Detectors’ L+ LC, polarized
Provided current is not over 1.3mA/DC24V
FIRE ALARM SYSTEM
I/O Modules
Control Modules
1 In 1 Out
Control Modules 1 In 1 Out (with isolation function)
Coomunication isolation function, when short circuit occurred in the module, the
module will be automatically isolated from the main communication line.
FEATURES
Bult-in tri-state LED indicator to indicate different
statuses, “Monitoring”, “Disconnection”, and HS-ADD-I/O-1
“Fire State”. SPECIFICATIONS
Binary coded address dip switch EOL : Resistor 330 + Capacitor 4.7 uF 50V
Two-wire multi-transmission Operating Environment : 0 C- 50 C relative
Stable communication with resistance to noise humidity below 85%
and disturbances Monitoring Current : 10mA
Self-test function for circuit disconnection and Activating Current : 16mA
activation Load Voltage Input : 24V DC
Expandable to connect with photoelectric Rated Voltage : 33V AC
smoke, rate of rise heat and fixed temperature Output Contact Capacity : 30V DC / 2A (max)
heat detectors Material : Flame retardant plastic
LED indication pattern, as follows : Dimensions : 80 (H) x 60 (W) x 30 (D) mm
monitoring (flash at intervals of 2.5s),
disconnection (flash at intervals 0.5s) and fire
state (on)
Can be fixed on alumunium railings for easy
installment