0% found this document useful (0 votes)
37 views1 page

Design of Two Way Slab Slab S1 Mumpty of Shri Muley

The document provides design details for a two-way slab (S1) including given data on dimensions, materials, and loading. Key details calculated include the slab thickness of 150mm, ultimate bending moments of 19560149Nmm and 11475137Nmm, minimum steel reinforcement of 180 sqmm, and main bar diameters of 8mm and spacings of 75mm and 75mm which meet code requirements for deflection.

Uploaded by

viprade69
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views1 page

Design of Two Way Slab Slab S1 Mumpty of Shri Muley

The document provides design details for a two-way slab (S1) including given data on dimensions, materials, and loading. Key details calculated include the slab thickness of 150mm, ultimate bending moments of 19560149Nmm and 11475137Nmm, minimum steel reinforcement of 180 sqmm, and main bar diameters of 8mm and spacings of 75mm and 75mm which meet code requirements for deflection.

Uploaded by

viprade69
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

DESIGN OF TWO WAY SLAB SLAB S1

Mumpty of Shri Muley TYPE= TWO WAY

** Given Data :-
1Longer Span c/c ly = 4120 mm
2Shorter Span c/c lx = 2630 mm
3Width of Support bw = 230 mm
4Live load wl = 15 kN/sq.m
5Floor Finish wff = 1 kN/sq.m SAFE
6Concrete Grade M20 fck = 20 N/sqmm
7Steel Grade Fe415 fy = 415 N/sqmm
Fe250 fy = 250 N/sqmm
8 Effective Cover to R/F = d' = 25 mm
9 Boundry Conditions
Longer Edge1 = Discontinuous Cl1= 1
Longer Edge2 = Discontinuous Cl2= 1 1 for Discontineous edge
Shorter Edge1= Discontinuous Cs1= 1 1.5275 for contineous edge
Shorter Edge2= Discontinuous Cs2= 1
No. of discontineous Edges Nd= 4

** Design Constant
Modulus of Elasticity of Stee Es= 2.00E+05 N/sq.mm
Limiting NA factor Kulim = 4.79E-01
Limiting MR factor Rulim = 2.78E+00
Limititing % Tensile Steel ptlim= 0.960755

** Span Ratio r = 1.56654

** Slab Thickness Based on Deflection criteria

Overall Depth D = lx/32 = 82.1875 150 mm Say


Effectve Depth dx = D-d' = 125 mm
dy =dx -10 = 115 mm
** Loading on Slab

Self weight = D * 25 = 3.75 kN/sq.m


Live Load = 15.00 kN/sq.m
Floor finishes = 1.00 kN/sq.m
Total Working load w = 19.75 kN/sq.m
Factor load wu = 29.625 kN/sq.m
** Codal moment coefficients for Restrained slab

At Mid Span At Contineous Support


+ve -ve

Shorter Span Coeff 0.0954558 0.127274


Longer Span Coeff. 0.056 0.074667

** Ultimate Design Moments in N mm

Along Shorter Direction 19560149 26080199


Along Longer Direction 11475137 15300183

** Check for depth by maximum bending moment consideration

d = Sqrt(+veMux/(Rulim*b)) 83.920443 mm < d provided = 125 mm O.K.

** Flexural R/F requirement in sq.mm

Along Shorter Direction 470 648


Along Longer Direction 292 397

** Minimum Area of R/F

Astmin = 0.12*b*D/100 = 180 Sq. mm

** Diameter & Spacing of Main Bars

Along Shorter Direction Dia 8 8


Spacing 107 78
75 mm Say 75 mm Say

Along Longer Direction Dia 8 8


Spacing 172 127
75 75 mm Say

** Check for Deflection

pt = 0.536381 kt = 1.203406 1.361253

Basic lc/d Ratio = 26*kt = 31.28855

Actual lc/d Ratio = 19.2 < Basic lc/d ratio = 31.28855

SAFE