100% found this document useful (1 vote)
702 views4 pages

Wind-Asce 7-10

The document provides an example of calculating wind loads on a structure according to ASCE 7-05 and ASCE 7-10 standards using the directional method. It gives input data for a sample structure and shows the calculations to determine velocity pressures, wind pressures at different levels, and average and net pressures on the main wind force resisting system and parapets.

Uploaded by

Mohammed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
702 views4 pages

Wind-Asce 7-10

The document provides an example of calculating wind loads on a structure according to ASCE 7-05 and ASCE 7-10 standards using the directional method. It gives input data for a sample structure and shows the calculations to determine velocity pressures, wind pressures at different levels, and average and net pressures on the main wind force resisting system and parapets.

Uploaded by

Mohammed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

ASCE Wind Load©

According to ASCE 7-05 & ASCE 7-10

Ver. 1.1

Please send your comments & suggestions to improve this tool on


[email protected]

by
Mahmoud M. El-Kateb, Ph.D

Structural Engineering Dept.


Faculty of Engineering - Ain Shams University
According to ASCE 7-05 & ASCE 7-10 By: Dr. Mahmoud El-Kateb
Version 1.1

* Wind load calculation


on MWFRS using Directional method

* Project :

INPUT DATA:
ASCE 7-05 ASCE 7-10
Basic wind speed (v) = 40 m/s 51 m/s
89 mph 113 mph
Directionality Factor (Kd) = 0.85 Buildings, component and cladding
Surface Roughness Category: B Urban and suburban areas
Exposure Category: C Section 26.7.3
Topographic Factor (Kzt) = 1.00 Section 26.8.2
Mean Height of the structure (h) = 20 m
Horizontal length of structure (L) = 20 m
Horizontal breadth of structure (B) = 30 m
Approximate natural frequency (na) = 3.75 Hz Other steel and concrete lateral system
Hence, structure is: Rigid
Gust effect Factor (G) = 0.86 Automatically computed Section 26.9
Terrain Exposure constants:
a= 9.5 zg = 274.32 c= 0.2 l = 152.4 e = 0.2
zmin = 4.57 a`= 0.154 b`= 0.65 Table 26.9-1
Enclosure classification: Enclosed --> GCpi = 0.18

OUTPUT DATA:
Directional procedure for determination of MWFRS loads: Automati
Velocity Pressure Exposure Coeffiecient (Kh) = 1.16 Table 27.3-1
External pressure coefficient (Cp) = 0.8 for Windward wall Figure 27.4-1
External pressure coefficient (Cp) = 0.5 for Leeward wall Figure 27.4-1
ASCE 7-05 ASCE 7-10
Velocity pressure (qh) = 0.97 kN/m 2
1.55 kN/m2

Wind pressure Wind pressure


According to ASCE 7-05 Case 1, kN/m2 Case 2, kN/m2 Wind force
Level Z (m) Kz qz Windw Leew Windw Leew up to level
up to 0.25 h 5.0 0.87 0.72 0.32 0.49 0.67 0.14 121.5 kN
up to 0.50 h 10.0 1.00 0.83 0.40 0.53 0.75 0.19 140.6 kN
up to 0.75 h 15.0 1.09 0.91 0.45 0.57 0.80 0.22 153.1 kN
up to 1.00 h 20.0 1.16 0.97 0.49 0.59 0.84 0.24 162.7 kN
Total service wind force = 578 kN

384447480.xls 2 of 4
According to ASCE 7-05 & ASCE 7-10 By: Dr. Mahmoud El-Kateb
Version 1.1

* Wind load calculation


on MWFRS using Directional method

Wind pressure Wind pressure


According to ASCE 7-10 Case 1, kN/m2 Case 2, kN/m2 Wind force
Level Z (m) Kz qz Windw Leew Windw Leew up to level
up to 0.25 h 5.0 0.87 1.15 0.52 0.78 1.08 0.22 194.4 kN
up to 0.50 h 10.0 1.00 1.34 0.64 0.86 1.20 0.30 225.0 kN
up to 0.75 h 15.0 1.09 1.45 0.73 0.91 1.28 0.35 245.0 kN
up to 1.00 h 20.0 1.16 1.55 0.79 0.95 1.35 0.39 260.3 kN
Total ultimate wind force = 925 kN

Average on the whole structure:


Equivalent height to calculate the average = 11.4 m
Equivalent Velocity Pressure Exposure Coeffiecient (K h) = 1.03
ASCE 7-05 ASCE 7-10
Case 1, +ve internal pressure:
Design windward pressure on MWFRS = 0.44 kN/m2 0.70 kN/m2
Design leeward pressure on MWFRS = 0.52 kN/m2 0.84 kN/m2
Case 2, -ve internal pressure:
Design windward pressure on MWFRS = 0.75 kN/m2 1.20 kN/m2
Design leeward pressure on MWFRS = 0.22 kN/m2 0.35 kN/m2
Minimum value = 0.48 kN/m2 0.77 kN/m2
Total wind force on structure = 578 kN 925 kN

384447480.xls 3 of 4
According to ASCE 7-05 & ASCE 7-10 By: Dr. Mahmoud El-Kateb
Version 1.0

* Wind load calculation


on Parapets of MWFRS using Directional method

* Project :

INPUT DATA:
ASCE 7-05 ASCE 7-10
Basic wind speed (v) = 40 m/s 51 m/s
89 mph 113 mph
Directionality Factor (Kd) = 0.85 Buildings, main wind force resisting system
Surface Roughness Category: B Urban and suburban areas
Exposure Category: C Section 26.7.3
Topographic Factor (Kzt) = 1.00 Section 26.8.2
Top level of parapet (h) = 20 m
Terrain Exposure constants:
a= 9.5 zg = 274.32 c= 0.2 l = 152.4 e = 0.2
zmin = 4.57 a`= 0.154 b`= 0.65 Table 26.9-1

OUTPUT DATA:
Velocity Pressure Exposure Coeffiecient (Kh) = 1.16 Table 27.3-1
Combined net pressure coefficient (GCpn) = 1.5 for Windward parapet
Combined net pressure coefficient (GCpn) = 1.0 for Leeward parapet

ASCE 7-05 ASCE 7-10


Velocity pressure (qh) = 0.97 kN/m 2
1.55 kN/m2
Design windward pressure on parapet = 1.45 kN/m2 2.32 kN/m2
Design leeward pressure on parapet = 0.97 kN/m2 1.55 kN/m2

384447480.xls 4 of 4

You might also like