Powerlink 20 KVA Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8
At a glance
Powered by AI
The document provides specifications for a 20kVA soundproofed generator set including details about the engine, alternator, control system, and safety features.

The generator set uses a Perkins 404A-22G1 engine.

The generator set uses a STAMFORD PI144D alternator.

WPS20S/ 1000025083

20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Features:
• Perkins engine
• STAMFORD Alternator, Class H
• Genset Canopy IP44 protection, Control panel
IP56 protection
• Control module PLC-7420
• Breaker: NADER 32A
• Speed governor: Mech governor
• Excitation system: Brushless
• A.V.R model: AS480
• 50℃ radiator
• Fire extinguisher
• Oil pump on the engine
• ATS receptacle
• Lockable battery isolator switch
• Powder coated canopy
Output Ratings
• Vibration isolators between the engine/Alternator
and base frame Generator Set Prime Power Standby Power
• Integrated wiring design Model kVA kW kVA kW
• High water temperature protection
WPS20S 20 16 22 17.6
• Steel base frame with forkslots
Ratings at 0.8 power factor
• Big daily fuel tank

Dimensions and Weights Ratings and Performance Data

Dry Weight- Engine Brand Perkins


Model L × W × H-mm
kg Engine Model 404A-22G1
WPS20S 2300× 863× 1358 961 Alternator Brand STAMFORD

Notes: Alternator Model PI144D


*Prime Power Continuous duty operation, under variable load 24/24h-10% Control System PLC-7420
over load permissible 1 hour/12 hours;
**Standby Power Standby duty, operation under variable load, without over
Circuit Breaker Type NADER 32A
load; Frequency / Phase 50Hz/3Phase
Standard Reference Conditions Note: Standard reference conditions
25°C (77°F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Engine Speed(RPM) 1500
Fuel Tank Capacity(L) 140
Fuel Consumption(L/h)
5.3
(100%load)
Model Type Soundproofed
Standard Package Plastic
Noise Level@7m(dBA) 65
Generator set Manufacture PowerLink
Oil Consumption(L/h) 0.0106
Volatage(V) 380/400/415/440
Silencer Noise
10-20
Reduction(dBA)

www.powerlinkworld.com | [email protected] 1/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Engine Model:404A-22G1

Engine Technical Data Exhaust and silencer System

Engine Model 404A-22G1 Exhaust Air Flow(m³/hr) 236.4


Engine Brand Perkins Exhaust Air Temp.(°C) 505
Number of Cylinders 4 Maximum Allowable Back
10.2
Cylinders Arrangement In-line Pressure(mmhg)
Bore/Stroke(mm) 84/100 NOx(mg/Nm³)
Speed(RPM) 1500 Silencer Quantity 1
Displacement(L) 2.2 Silencer Type Industrial silencer
Compression Ratio 23.3
Cooling System
Air Intake system Naturally aspirated
Cooling Method Water cooled Radiator 50
Coolant Capacity(L) 7 Coolant Capacity(L) 7
Prime Power(kWm) 18.4 Coolant Change Time(Year/h) 2/10000
Standby Power(kWm) 20.3 Coolant Intake Temp.(°C) 40
Governing Type Mech Coolant Output Temp.(°C) 110
Back Pressure(mmhg) 10.2 Designed to operate in ambient conditions up to 50°C (122°F).Contact
your local PowerLink Dealer for power ratings at specific site conditions
Battery(V) 12

Fuel System Air Intake system

Fuel Tank steel Air Filter Type Dry type


Fuel Tank Capacity(L) 140 Intake Air Flow(m³/h) 87
Fuel tank type Double-layer Intake System Naturally aspirated
Recommended Fuel Type 0# or ASTM2 Intake Air Temp.(°C) 25
Injection System Direct injection
Fuel Consumption:
100% 75% 50% 25%
WPS20S
Load Load Load Load
L/h 5.3 4 2.9 1.334
(Based on diesel fuel with a specific gravity of 0.85 and conforming to
BS2869,Class A2)

Lubrication System Conditions

Lube oil label Altitude(m)


Maximum Oil Temp.(°C) 125 Ambient Temp.(°C) -5℃-50℃
Oil capacity(L) 10.6 Barometric Pressure(kpa) 100
Relative Humidity <80%

www.powerlinkworld.com | [email protected] 2/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Alternator Model:PI144D

Alternator Physical Data Alternator Operating Data

AVR Model AS480 Overspeed(rpm) 2250


Alternator Brand STAMFORD Voltage Reguation(Steady state) ± 1.0 %
Alternator Model PI144D THF(BS EN60034-1) <50
Excitation System Brushless TIF(NEMA MG 1-22) <2%
Housing Protection IP23 Air Flow(m³/s)-Alternator
0.1
Power Factor 0.8 50Hz/60Hz
Rated Stator Temp. rise(℃) 125 Altitude-Alternator(m) 1000
Rotor Insulation Class H
Voltage Fluctuation(no load to
±0.5%
full load)
Winding Pitch 2/3
Wiring Connection Series Star

Performance Data Voltage Technical Data

Time constants/400V(Ms) Prime Standby


Voltage
T’d 0.019 s kVA kW kVA kW
T’’d 0.005 s 380V@50Hz 20 16 22.0 17.6
T’do 0.45 s
400V@50Hz 20 16 22.0 17.6
Ta 0.007 s
415V@50Hz 20 16 22.0 17.6
Short-circuit current (3 IN / 10 s) 300 % (3 IN) : 10s
SHORT CIRCUIT RATIO 1/Xd 415V@60Hz 23.5 18.8 25.85 20.68

Reactances(Per Unit) 440V@60Hz 24.3 19.44 26.73 21.384


Xd 480V@60Hz 25 20 27.5 22.0
X'd
X"d

www.powerlinkworld.com | [email protected] 3/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Overall Dimensions

www.powerlinkworld.com | [email protected] 4/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

www.powerlinkworld.com | [email protected] 5/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Control System

www.powerlinkworld.com | [email protected] 6/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Product Standard Configuration

Alternator Control System Fuel System Lubrication System Cooling System

Alternator PLC-7420 Control Base Fuel Tank Lube Oil Drain Pump 50℃ Radiator
A.V.R System Water Separator Fuel External Water Inlet
Observation Window and Prefilter Supplied with Coolant
Control Door Fuel Tank Drain Protection Mesh for Fan
Air Breaker Fuel Level Control Panel and Revolving Parts
External Cable Display
Connection
Cable Line Slot

Air intake system Exhaust system Shipment and Installation Safety protection devices Technical documents

Air Filter Industrial Silencer Forklift Lifting Points Earth Protection Genset Operation
Intake Air Filter Screen Heat Insulation Lifting Lug Oil Pressure Manual
Intake Air Silencer Protective Sleeve Dragging Hole Warning/Downtime Engine Operation Manual
Exhaust Outlet with Side Collision Avoidance Water Temperature Alternator Operation
Flexible Design Warning/Downtime Manual
Heat Hand Protection Base Mounting Hole Water Level Genset Test Report
Warning/Downtime Ganset Circuit Diagram
Speed Genset Installation
Warning/Downtime Drawings
External Emergency Stop Maintenance Manual
Maintenance Records

Engine Machine Body - - -

Water-Cooled Engine Silence Cotton Inside


Battery Canopy
Battery Switch Central Lifting Point
Draining Oil Pump Baseplate with Retention
Standard Air Filter Tank
Electronic Governor Forklifts
Radiator Core Guard
Battery Charger
Air Filter with
Replaceable Cartridge

www.powerlinkworld.com | [email protected] 7/8


WPS20S/ 1000025083
20kVA, Soundproofed, 404A-22G1, PI144D, 3phase, AMF

Optional Configuration

Alternator Control System Fuel System Lubrication System Cooling System

PMG PLC-920 Control System External Fuel Filling Auto Refilling Oil System 45℃ Radiator
Anti-condensation PLC-8610 Control Device Lube Oil Preheater 40℃ Radiator
Heater System Fuel Level Gauge Oil Level Gauge
Winding Temperature Leak Protection Device Auto Refilling Diesel Lube Oil Temperature
Measurement System Sensor
Oil Pan
Fuel Three-Way Value

Air intake system Exhaust system Voltage Wheel Braking System Safety protection devices

Forced Air Inlet System Residential Silencer 415/240V Trailer-Roadside Type RCD Protection
Intake Air Preheating 400/230V Trailer-Off-Road Type Oil Level
System 380/220V Trailer Suspension Warning/Downtime
220-240V-SINGLE System Imbalanced Three-phase
PHASE Warning/Downtime
220/127V Spark-extinguishing
480/277V Device
440/254V Anti-lightning Installation
Secure Transportation
Open the Door Shutdown
Protection
Extinguisher
Explosion-proof Lamp
No-skid Floor
Rest Area

High-tech configuration Optional configuration Technical documents Engine -

Remote Control Three-way Catalytic Genset Parts Manual Jacket Water Heater
Remote Communication Converter Engine Parts Manual 220/240V
and Diagnosis Engine Triple Painted Genset Tools Package Oil Heater
Remote Monitor Genset Parallel Heavy Duty Air Filter
Auto Start-Stop System Installation Block Heater
Alert Message External Fuel Tank
Notification SECC Base Frame
Maintenance Cycle Stainless Steel Exhaust
Notification System
4 Poles Circuit Breaker
ATS
Quick Connector
Fuel Leaking Protection

Specification may change without prior notice. For more info,


please contact PowerLink or your local distributors.

EP Series / 2017-03-19

www.powerlinkworld.com | [email protected] 8/8

You might also like