Design Calculations
Design Calculations
CASE 2 :
Maximum moment along X direction (M x) = 764 kNm
Corresponding moment along Y direction (M y) [Ref. : STAAD
= 62 kNm Output]
Corresponding axial load (Fc) Nu = 1387 kN
Resultant Moment Mu = 766.51 kNm
N/h2 = 1.39
M/h3 = 0.77
From chart 11 of CP 110 100*Asc/Ac = 0.40
Asc = 3141.59 mm2
No. of Bars of 20 dia = 10.00 Nos.
Max. tension = 0.00 kN
Allowable tensile stress of reinforcement = 460.00 N/mm2
Area of reinforcement required = 0.00 mm2
No. of bars of 20 dia required = 0.00 Nos.
Hence Provide 20 dia 0 Nos. 0.00 mm2
No shear check is necessary if Mu/Nu < 0.6 h
4.8979 < 600
No shear check
However Provide 8 dia 300c/c helical reinforcement
Design of Beam
K = 0.0152003637
Z = 0.98 d
0.95 d
Ast = 3046.55 mm2
Hence provide shear reinforcement 8 dia 2 legged @100 c/c per meter width
Design of Slab-350 Thick
K = 0.0354442344
Z = 0.96 d
0.95 d
Ast = 1286.54 mm2
[Ref. : STAAD
Output]
Ref. staad output
K = 0.0186804483
Z = 0.98 d
0.95 d
Ast = 5048.57 mm2
Hence provide shear reinforcement 8 dia 6 legged @125 c/c per meter width
Sagging Moment @ Span