0% found this document useful (0 votes)
79 views1 page

Design of Combined Footing For Staircase Columns: Project Structure Document Title

This document provides the design details of a combined footing to support two staircase columns. Key details include: - The footing is designed to support column reactions of 10 kN (ULS) and 6.7 kN (SLS) for Column 1, and 80 kN (ULS) and 55.2 kN (SLS) for Column 2. - The footing has dimensions of 1600mm x 900mm x 250mm deep and reinforcing steel is specified. - Calculations show the bearing pressure is below the allowable soil bearing capacity for both SLS and ULS loading conditions. - Shear and punching shear capacities are also checked and found to be adequate.

Uploaded by

risriz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views1 page

Design of Combined Footing For Staircase Columns: Project Structure Document Title

This document provides the design details of a combined footing to support two staircase columns. Key details include: - The footing is designed to support column reactions of 10 kN (ULS) and 6.7 kN (SLS) for Column 1, and 80 kN (ULS) and 55.2 kN (SLS) for Column 2. - The footing has dimensions of 1600mm x 900mm x 250mm deep and reinforcing steel is specified. - Calculations show the bearing pressure is below the allowable soil bearing capacity for both SLS and ULS loading conditions. - Shear and punching shear capacities are also checked and found to be adequate.

Uploaded by

risriz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project DEDURUOYA WATER SUPPLY PROJECT

Structure FLASH MIXER,FLOCCULATION TANK & LAMELLA CLARIFIER


Document Title DESIGN OF STAIRCASE - 01

DESIGN OF COMBINED FOOTING FOR STAIRCASE COLUMNS

MATERIALS
fcu 25 N/mm² Soil 20 kN/m³ γc 1.5
fy 460 N/mm² cover 40 mm γs 1.15
Densities - Concrete 25 kN/m³ Deepth 2.65 m
Bearing pressure 200 kN/m² (net allowable)

COLUMN REACTIONS, kN
ULS SLS
Column 1 10.0 6.7 B
Column 2 80.0 55.2
ex2 ex1
DIMENSIONS mm
BASE COLUMN 1 (RHS) COLUMN 2 (LHS) L
L = 1600 h1 = 200 h2 = 200
B = 900 b1 = 200 b2 = 200
depth H = 250
ex1 + ex2 = 800 ex1 = 700 ex2 = 100

Bearing Pressure
2
Base pressure - SLS = 43 kN/m Below soil bearing capacity
2
Base pressure - ULS = 63 kN/m

REINFORCEMENT . .
2
f= 62.50 kN/m
Mxx = 10.1 kNm Myy = 6.1 kNm
b= 900 mm b= 1600 mm
d= 195 mm d = 205.00 mm
As = 137 mm² As = 590 mm²
Provide, T 10 @ 150 Provide,T 10 @ 150
As,provided = 471 mm² As,provided = 838 mm²
As, % = 0.269% As, % = 0.255%
.
BEAM SHEAR .
Shear at (b-c)/4= 350 mm from col face Shear at (b-c)/4= 175 mm from col face
Vxx = 25.3 kN at d from col face Vyy = 18 kN at d from col face
v= 0.144 N/mm² v= 0.053 N/mm²
vc = 0.488 N/mm² vc = 0.474 N/mm² OK

PUNCHING SHEAR Vmax too big


d ave = 200 mm u crit = 3200 mm
As prov = 0.262% V= 50 kN
vc = 0.481 N/mm² v= 0.078 N/mm² OK