819-6043 Jul 08
819-6043 Jul 08
819-6043 Jul 08
INSTALLATION INSTRUCTIONS
8261817
8262017
8262018
8262019
8262020
8262021
WARNING
Natural to Propane Gas Conversion Kit Propane to Natural Gas Conversion Kit
8261817* 8262017*
For use in SM40 and SR42 Series Fryers For use in SM40 and SR42 Series Fryers
This Kit Contains: This Kit Contains:
3 1.70MM Burner Orifices P/N 8103361 3 2.80MM Burner Orifices P/N 8103360
1 Pilot Orifice P/N 8102400 1 Pilot Orifice P/N 8100811
1 Regulator Conversion Kit P/N 8071846 1 Regulator Conversion Kit P/N 8071849
1 Conversion Date Label P/N 8022144 1 Conversion Date Label P/N 8022144
1 SM40/SR42 Conversion Label P/N 8022240 1 SM40/SR42 Conversion Label P/N 8022241
3 Bushing P/N 810-3147 3 Bushing P/N 810-3147
* Kits include bushings to fit new smaller orifices
into older manifold openings.
Natural to Propane Gas Conversion Kit Propane to Natural Gas Conversion Kit
8262018 8262019
For use in SM50 and SR52 Series Fryers For use in SM50 and SR52 Series Fryers
This Kit Contains: This Kit Contains:
4 1.51MM Burner Orifices P/N 8102059 4 2.53MM Burner Orifices P/N 8102048
1 Pilot Orifice P/N 8102400 1 Pilot Orifice P/N 8100811
1 Regulator Conversion Kit P/N 8071846 1 Regulator Conversion Kit P/N 8071849
1 Conversion Date Label P/N 8022144 1 Conversion Date Label P/N 8022144
1 SM50/SR52 Conversion Label P/N 8022242 1 SM50/SR52 Conversion Label P/N 8022243
Natural to Propane Gas Conversion Kit Propane to Natural Gas Conversion Kit
8262020 8262021
For use in SM60 and SR62 Series Fryers For use in SM60 and SR62 Series Fryers
This Kit Contains: This Kit Contains:
5 1.51MM Burner Orifices P/N 8102059 5 2.53MM Burner Orifices P/N 8102048
2 Pilot Orifices P/N 8102400 2 Pilot Orifices P/N 8100811
1 Regulator Conversion Kit P/N 8071846 1 Regulator Conversion Kit P/N 8071849
1 Conversion Date Label P/N 8022144 1 Conversion Date Label P/N 8022144
1 SM60/SR62 Conversion Label P/N 8022244 1 SM60/SR62 Conversion Label P/N 8022245
Installation Instructions
1. Shut off the gas supply to the fryer and disconnect the fryer from the electrical power
supply.
2. Remove the burner heat shield to expose the burner mounting bolts.
3. Loosen but do not remove the burner mounting bolts.
4. One at a time, lift the burners up and disengage them from the burner bracket, then lift
them up and off the burner orifices.
5. Unscrew the existing burner orifices from the manifold and replace them with those in
the kit. Use bushings, as necessary, to fit smaller SM40/SR42 orifices to manifold.
6. Unscrew the gas tube from the pilot burner and carefully pull it away from the pilot
burner.
7. The pilot orifice should drop out of the pilot hood. If it does not, gently pry it out.
8. Insert the replacement pilot orifice in the hood and reconnect the gas tube.
9. Convert the gas valve regulator in accordance with the instructions furnished with the
regulator conversion kit.
10. Reinstall the burners by slipping them over the burner orifices and engaging the
mounting bolts in the keyhole slots in the mounting bracket. Tighten the mounting bolts.
11. Verify that the incoming gas pressure is in accordance with the appropriate table in the
Installation and Operation Manual for the fryer being converted.
12. Open the gas supply to the fryer and check for leaks using a solution of soapy water
applied to each connection in the fryer’s gas supply system.
13. Turn off the gas supply to the fryer. Attach a manometer to the burner manifold pressure
tap then reconnect the fryer to the electrical power supply.
14. Light the pilot in accordance with the instructions in the Installation and Operation
Manual for the fryer being converted and verify that the pilot flame is approximately
1-inch long. If adjustment is necessary, remove the pilot flame adjustment screw cap on
the gas valve and, using a small flat-tipped screwdriver, turn the adjustment screw
counterclockwise to increase the length of the flame or clockwise to decrease it.
Reinstall the cap when adjustments are completed.
15. Verify that there is cooking oil or water in the frypot. Place the gas valve in the ON
position to light the burners. Verify that each burner lights and that the manifold
pressure is in accordance with the appropriate table in the Installation and Operation
Manual. Adjust the burner manifold pressure as required by turning the regulator
adjustment screw clockwise to increase the pressure or counterclockwise to reduce the
pressure.
16. Shut off the gas supply to the fryer. Disconnect the manometer and reinstall the
pressure tap plug.
17. Open the gas supply and use a solution of soapy water to verify the plug is not leaking.
18. Light the fryer and verify proper operation in accordance with the instructions in the
Installation and Operation Manual.
19. On the inside of the fryer door, apply the conversion label as close to the data plate as
possible and affix the conversion date label where it can best be seen.
Page 3 of 4 819-6043 JUL 2008
Typical Burner and Pilot Configuration
The assembly illustrated is typical of the burner manifold and pilot assemblies
for which these kits are designed. It is representative in nature and is intended
to identify the various components to be replaced. The actual assembly may
differ slightly in appearance.
Page 4 of 4
Steps 3 and 4: Loosen but do not
remove the burner bolts. Disengage
the burners from the bracket and lift
them up and off the burner orifices.