R.R. Rojo and Associates: Anchor Bolt Design The Anchor Rod Design Is Adequate

The document summarizes the design of anchor bolts for a structure. It analyzes the anchor bolt design based on various loadings and material properties. It calculates the tensile, shear, and bearing capacities of the anchor bolts and checks that the design capacities exceed the factored loads. The anchor bolt design is determined to be adequate based on the analysis.

Uploaded by

Mark
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
232 views10 pages

R.R. Rojo and Associates: Anchor Bolt Design The Anchor Rod Design Is Adequate

The document summarizes the design of anchor bolts for a structure. It analyzes the anchor bolt design based on various loadings and material properties. It calculates the tensile, shear, and bearing capacities of the anchor bolts and checks that the design capacities exceed the factored loads. The anchor bolt design is determined to be adequate based on the analysis.

Uploaded by

Mark
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 10

Project:

R.R. Rojo and Associates


Prepared by: Checked by: Location:

ANCHOR BOLT DESIGN


RESULT The Anchor Rod Design Is A
Loadings:
Mu = 163 kN-m.
Pu = 667.2 kN
Vu = 71.2 kN

Properties:
Concrete Strength fc' = 21 MPa
Strength of Anchor futa = 400.2 MPa
Base Plate Yield Strength fy = 248 MPa
Base Plate Cantilever m= 100 mm.
Eff. Embedment Depth hef = 400 mm.
Anchor Diameter d= 25 mm.
Type of Anchor Head Square
Apply Seismic Load Factor? Yes
Ω= 2.5
Ase,N = 390.967 mm^2
Ab = 945.159 mm^2
distance between Fastener an ca1 = 300 mm
distance between Fastener an ca2 = 230 mm
Anchor Bolt Location to Work Point

Bolt Number X Y
1 -203.2 203.2
2 -203.2 0
3 -203.2 -203.2
4 203.2 203.2
5 203.2 0
6 203.2 -203.2
Analysis:
Anchor Forcces Without Concrete Compression Forces Being Considered
cg of bolt from work point
XCG of bolt YCG of bolt
0 0

Bolt Number X Y XCG2


1 -203.2 203.2 41290.24
2 -203.2 0 41290.24
3 -203.2 -203.2 41290.24
4 203.2 203.2 41290.24
5 203.2 0 41290.24
6 203.2 -203.2 41290.24
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
247741.4
Tensile Anchor Strength
Nua,1 = 56.236 kN

φNsa = φAse,N(futa) = 117.349 kN >

Concrete Breakout Strength of Governing Anchor


φNcb = φ(ANC/ANCo)Ψec,NΨed,NΨc,NNb = φ(AN/9h2ef)Ψec,N1.0Ψc,N(24√(fc')hef1.5)
φ 0.5625
ANCo = 1440000 mm^2
AN = 1080000 mm^2
AN = 0 1/4 of ANCo **Conservative Value
Used AN = 1080000 mm^2
Ψec,N = 1.0, for no eccentricity in the connection.
Ψc,N = 1.0, for location where concrete cracking is likely t
φNcb = 371.189 kN >

Concrete Breakout Strength of All Anchor


φNcbg = φ(ANC/ANCo)Ψec,NΨed,NΨc,NNb = φ(AN/9h2ef)Ψec,N1.0Ψc,N(24√(fc')hef1.5)
φ= 0.5625
ANCo = 1440000 mm^2
AN = 1615232.96 mm^2
Used AN = 1615232.96 mm^2
Ψec,N = 1 1.0, for no eccentricity in the connection.
Ψc,N = 1 1.0, for location where concrete cracking is likely t
φNcbg = 555.145 kN >

Pull out Strength of Governing Anchor


φNpn = φΨcp,N(Ab8fc')
φ= 0.5625
Ab = 945.159
Ψcp,N = 1 for concrete cracking likely to occur
φNpn = 89.318 kN >

Side-face Blowout Strength


φNpn =φ13ca1√(Abrg)λa√(fc')
φ= 0.5625
Ab = 945.1594 mm^2
ca1 = 300 mm.
ca2 = 230 mm.
ca2 < 3ca1
ca2/ca1 = 0.766667 0.7666666667
factor = 1
φNpn = 309.0646327042 kN >

Design Tensile Strength of Governing Anchor


φNn = min(φNsa,φNcb,φNpn,φNpn)
φNn = 89.318 kN

Shear Strength of Governing Anchor


φVsa = φ0.60*Ase,Vfuta
φ= 0.65
Ase,V = 390.96696 mm^2
φVsa = 61.021 kN >
**first factor shall be multiplied by 0.8, for built-up grout pads

Breakout Strength of Governing Anchor For Shear

φVcb = φ(AVC/AVCo)Ψec,VΨed,VΨc,VVb = φ1.0Ψec,V1.0Ψc,V(0.6(le/d)0.2√(d)√(fc')(hef)1.5


φ= 0.75
Ψec,V = 1 for no eccentricity in the connection.
Ψc,v = 1 for location where concrete cracking is likely to oc
le/d = 8 should not exceed 8
φVcb = 125.026 kN >

Breakout Strength of All Anchor For Shear


φVcbg = φ(AVC/AVCo)Ψec,VΨed,VΨc,VVb = φ(Av/4.5(1.5hef)^2)Ψec,V1.0Ψc,V(0.6(le/d)0.2√(d)√(fc')(hef)1.5
φ= 0.75
Ψec,V = 1 for no eccentricity in the connection.
Ψc,v = 1 for location where concrete cracking is likely to oc
le/d = 8 should not exceed 8
ca1 = 300 mm.
ca2 = 230 mm.
Av = 488880 mm^2
φVcbg = 84.8926 mm^2 >

Pryout Strength for Shear Load on Governing Fastener


φVcp = φkcp(ANC/ANCo)Ψed,NΨc,NNb = φkcp(AN/9h2ef)1.0Ψc,N(24√(fc')hef1.5)
φ= 0.75
Ψc,N = 1 for location where concrete cracking is likely to oc
kcp = 2 for hef ≥ 2.5mm
φVcp = 742.38 kN >

Pryout Strength for Shear Load on All Fastener


φVcpg = φkcp(ANC/ANCo)Ψed,NΨc,NNb = φkcp(AN/9h2ef)1.0Ψc,N(24√(fc')hef1.5)
φ= 0.75
Ψc,N = 1 for location where concrete cracking is likely to oc
kcp = 2 for hef ≥ 2.5mm
φVcpg = 1110.29 kN >

Design Shear Strength on Governing Anchor


φVn = min(φVsa, φVcb, φVpn)
φVn = 61.02 kN

Splitting Failure Check


ca1 > 0.4hef OK!
Note: No Splitting Failure Will Occur Since The Anchor Is Far From the Edge

Shear and Tension Interaction


Nua,2 > 0.2φNn Full Strength in Shear Shall Be
Vua,2 < 0.2φVn Full Strength in Tension Shall

Therefore, the Interaction, Equation may Be Used

Nua,2 Vua,2
+ =
φNn φVn
Description:

Date:

BOLT DESIGN
Anchor Rod Design Is Adequate.

BOLT GROUP
250
200
150
100
50
0
-250 -200 -150 -100 -50 0 50 100 150 200 250
-50
-100
-150
-200
-250
YCG2 Nua,1 Vua
41290.24 22.494 11.867
0 22.494 11.867
41290.24 22.494 11.867
41290.24 -244.894 11.867
0 -244.894 11.867
41290.24 -244.894 11.867
0
0
0
0
0
0
0
0
0
0
0
0
0
0
165161 -667.2 71.2
Nua = max(Nua,1) = 56.2356 kN OK!

**Conservative Value

city in the connection.


here concrete cracking is likely to occur.
Nua = 56.2356 kN OK!

city in the connection.


here concrete cracking is likely to occur.
-Pu = -667.2 kN OK!

ng likely to occur
Nua = 56.2356 kN OK!

Nua = 56.2356 kN OK!


Vua = 29.667 kN OK!

√(d)√(fc')(hef)1.5

n the connection.
concrete cracking is likely to occur.

Vua = 29.667 kN OK!

0Ψc,V(0.6(le/d)0.2√(d)√(fc')(hef)1.5

n the connection.
concrete cracking is likely to occur.

Vua = 61.021 kN OK!

concrete cracking is likely to occur.

Vua = 29.667 kN OK!

concrete cracking is likely to occur.

Vua = 61.021 kN OK!


Full Strength in Shear Shall Be Permitted
Full Strength in Tension Shall Be Permitted

0.82 < 1.2 OK!