PDS Hempadur 85671 en-GB
PDS Hempadur 85671 en-GB
PDS Hempadur 85671 en-GB
HEMPADUR 85671
APPLICATION DETAILS:
Version, mixed product: 85671
Mixing ratio: BASE 85675 : CURING AGENT 97371
8.8 : 1.2 by volume
13.8 : 1.0 by weight
Application method: Airless spray / Brush (touch up)
Thinner (max.vol.): HEMPEL'S THINNER 08450 (According to separate APPLICATION INSTRUCTIONS)
Pot life: 3 hour(s) 20°C/68°F
Induction time: 15 minute(s) 20°C/68°F (According to separate APPLICATION INSTRUCTIONS)
Nozzle orifice: 0.018 - 0.021 "
Nozzle pressure: 200 bar [2900 psi]
(Airless spray data are indicative and subject to adjustment)
Cleaning of tools: HEMPEL'S TOOL CLEANER 99610
Indicated film thickness, dry: 100 micron [4 mils] see REMARKS overleaf
Indicated film thickness, wet: 150 micron [6 mils]
Overcoat interval, min: According to separate APPLICATION INSTRUCTIONS
Overcoat interval, max: According to separate APPLICATION INSTRUCTIONS
-
Safety: Handle with care. Before and during use, observe all safety labels on packaging and paint containers,
consult HEMPEL Safety Data Sheets and follow all local or national safety regulations.
-
-
-
-
-
-
-
-
-
SURFACE PREPARATION: New steel: Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and other
contaminants by high pressure fresh water cleaning. Abrasive blasting to near white metal Sa 2½ (ISO
8501-1:2007) with a surface profile corresponding to Rugotest No. 3, BN10a, Keane-Tator Comparator
3.0 G/S, or ISO Comparator Medium (G).
Repair and maintenance: Remove oil and grease etc. thoroughly with suitable detergent. Remove
salts and other contaminants by high pressure fresh water cleaning. Other degrees of cleaning
including wet methods like ultra-high-pressure-water-jetting (UHPWJ) and blasting with mixtures of grit
and water may be relevant according to Hempel-specification. Remove water, any residual blasting
material and other debris. Old steel surfaces having been exposed to salt water, excessive amounts of
salt residues in pittings may call for abrasive blasting, high pressure fresh water hosing, drying, and
finally, dry abrasive blasting again.
Concrete: Remove slip agent and other possible contaminants by emulsion washing followed by high
pressure hosing with fresh water. Remove scum layer and loose matter to a hard, rough and uniform
surface, preferably by abrasive blasting, possibly by other mechanical treatment or acid etching. Seal
surface with suitable sealer, as per relevant painting specification.
APPLICATION CONDITIONS: Apply only on a dry and clean surface with a temperature above the dew point to avoid condensation.
Use only where application and curing can proceed at temperatures above: 10°C/50°F. The
temperature of paint itself should be 15°C/59°F or above. Curing requires a relative humidity of: max
80%.
In confined spaces provide adequate ventilation during application and drying.
Reference is made to separate APPLICATION INSTRUCTIONS.
PRECEDING COAT: None, or as per specification.
SUBSEQUENT COAT: None, or as per specification.
REMARKS:
Certificates/Approvals: The WRAS approval is valid once the final coating has cured for at least the following number of days:
7 days at 20°C/68°F followed by 3 hours at 85°C/185°F
or
7 days at 20°C/68°F followed by 8 hours at 60°C/140°F
Colours/Colour stability: Also available in colours that are low HAPS versions: 1163H/off white and 5090H/light red.
Film thicknesses/thinning: Film thicknesses:
May be specified in another film thickness than indicated depending on purpose and area of use. This
will alter spreading rate and may influence drying time and overcoating interval. Normal range is:
100-160 micron / 4-6.4 mils.
Thinning:
Keep thinning at absolute minimum. Do not dilute the components separately - only the mixture.
Shades: The natural tendency of epoxy coatings to chalk in outdoor exposure is also reflected in this product.
Overcoating: Overcoating intervals related to later conditions of exposure: If the maximum overcoating interval is
exceeded, roughening of the surface is necessary to ensure intercoat adhesion.
Before overcoating after exposure in contaminated environment, clean the surface thoroughly with high
pressure fresh water hosing and allow drying.
Overcoating note: The surface MUST be completely clean before overcoating. All dust, abrasives and loose dry spray
must be removed by vacuum cleaning. Dry spray should be removed by light abrading.The coating
may only be exposed to strong direct sunlight or ultraviolet light under exceptional circumstances and
then only for short periods.
The coating is to be checked carefully and any patchy, whitish, and/or greasy formation, must be
completely removed by suitable cleaning method.
Note: HEMPADUR 85671 For professional use only.
ISSUED BY: HEMPEL A/S 8567111150
X Move PDS Disclaimer to Second page