Example 5.3: A B C D
Example 5.3: A B C D
3 page1/11
Ref. Calculation Output
Specification
A B C D
L L L
1
w1 B
1a
w2
B
2
B
2a
B
3
Beam 1a/A-D
Page 1 of 11
page 2/11
Ref. Calculation Output
5.3.2.1 EFFECTIVE FLANGE WIDTH
beff
bw = 225 mm h
hf = 110 mm
h
h = 500 mm
b1 = 1387.5 mm
b2 = 1387.5 mm
bw
Permanent load ;
w0 = (0.50 - 0.11) x 0.225 x 25 = 2.19 kN/m
w1 = nLx/2 = 12.75 / 2.0 = 6.38 kN/m
w2 = nLx/2 = 12.75 / 2.0 = 6.38 kN/m
Gk = 14.94 kN/m
Variable load ;
w1 = nLx/2 = 9.00 / 2.0 = 4.50 kN/m
w2 = nLx/2 = 9.00 / 2.0 = 4.50 kN/m
Qk = 9.00 kN/m
Page 2 of 11
page 3/11
Ref. Calculation Output
Total design acrion on beam1a/A-D, wd
= (1.35 x 14.94) + ( 1.5 x 9.00) = 33.67 kN/m
Continuous beam with equal spans, uniform action and Qk<Gk, use moment and shear
coefficient from Table 3.14 BS 8110
A B C D
0.01 FL 0.01 FL
Bending Moment
0.09 FL 0.07 FL 0.09 FL
F = w d L kN = 269.4 kN
MAIN REINFORCEMENT
Span A-B & C-D
Effective depth,
d = h - C nom -Ø link - Ø bar1 = 454 mm
Mf = 0.567f ck bh f (d-0.5h f )
= 0.567 x 25 x 2140 x 110 x (454 - 55)
= 1331.4 kNm
K = M/fckbd2 6 2
= 194. x 10 / 25 x 2140 x 454
= 0.018
z = d[0.5 + (0.25-K/1.134) ]
= 454.0 [0.5 + (0.25 - 0.018/ 1.134)
= 446.85
As = M / 0.87fykz
6
= 194. x 10 / 0.87 x 500 x 446.8 Use : 5H 20
2
= 998 mm mm2)
( 1571
Page 3 of 11
page 4/11
Ref. Calculation Output
9.2.1.1 Minimum and maximum reinforcement area,
As, min = 0.26 (fctm / fyk) bd
= 0.26 (2.6 / 500) bd
= 0.0014 bd > 0.0013 bd Use : 0.0014 bd
= 0.0014 225 x 454
2
= 138 mm OK
Support B & C
Effective depth,
d = h - C nom -Ø link - Ø bar1 = 454 mm
K = M/fckbd2
= 237 x 10 6/ 25 x 225 x 454 x 454
= 0.204 > Kbal = 0.167
=>Compression reinforcement is required
x = (d - z) / 0.4 = 203.709 mm
Page 4 of 11
page 5/11
Ref. Calculation Output
Span B-C
Effective depth,
d = h - C nom -Ø link - Ø bar1 = 454 mm
Mf = 0.567f ck bh f (d-0.5h f )
= 0.567 x 25 x 1900 x 110 x (454 - 55)
= 1182 kNm
K = M/fckbd2 6 2
= 151. x 10 / 25 x 1900 x 454
= 0.015
z = d[0.5 + (0.25-K/1.134) ]
= 454.0 [0.5 + (0.25 - 0.015/ 1.134)
= 447.74
As = M / 0.87fykz
6
= 150. x 19 / 0.87 x 500 x 447.7 Use : 3H 20
2 2
= 775 mm ( 943 mm )
SHEAR REINFORCEMENT
6.2.3 Concrete strut capacity
V RD, max = 0.36b w df ck (1-f ck /250)/(cot Ө + tan Ө)
= 0.36 x 225 x 454 x 25 (1- 25 / 250) 25/250 = 0.1
(cotӨ + tanӨ)
Support A & D
V ED = 0.45F = 121 kN
Shear links
Asw/s = VED / 0.78fyk d cotӨ
= 121 x 10 3 / 0.78 x 500 x 454 x 2.5
= 0.277
Page 5 of 11
page 6/11
Ref. Calculation Output
Try link : H6 Asw = 57 mm2
Support B & C
V ED = 0.60F = 162 kN
0
V ED < V RD, max cot Ө = 2.5 , Ө = 22
V ED < V RD, max cot Ө = 1.0 , Ө = 45 0
0
Therefore angle, Ө < 22
Shear links
Asw/s = VED / 0.78fyk d cotӨ
3
= 162 x 10 / 0.78 x 500 x 454 x 2.5
= 0.369
Page 6 of 11
page 7/11
Ref. Calculation Output
Support B & C
V ED = 0.55F = 148 kN
Shear links
Asw/s = VED / 0.78fyk d cotӨ
= 148 x 10 3 / 0.78 x 500 x 454 x 2.5
= 0.338
Spacing, s = 57 / 0.180
= 314 mm < 341 mm Use :
H6 - 300
Shear resistance of minimum links
Vmin = (Asw/s)(0.78 d fyk cotӨ)
= (57 / 300) (0.78 x 454.0 x 500 x 2.5)
= 83 kN
Links arrangement
121 148 162 83
Page 7 of 11
page 8/11
Ref. Calculation Output
x1 = (121 - 83) / 33.67 = 1.147 m
x2 = (162 - 83) / 33.67 = 2.347 m
x3 = (148 - 83) / 33.67 = 1.947 m
0
v Ed = 3.59 kN 26.5 cot 27 = 2.0 tan 270 = 0.510
0
v Ed = 5.96 kN 45 cot 45 = 1.0
Page 8 of 11
page 9/11
Ref. Calculation Output
9.2.1(1) Minimum tranverse steel area,
As,min = 0.26(fctm/fyk)bhf
= 0.26 x (2.60 / 500) bhf
= 0.00135 bhf Use:
= 0.00135 x 1000 x 110 H10 -500
2
= 149 mm2 (157 mm )
7.4 DEFLECTION
Check at span A-B
Percentage of required tension reinforceent,
ρ = As req / bd
= 998 / x 225 x 454
= 0.010
1/2 1/2
= 1.3 [ 11 + 1.5 (25) 0.005 / ( 0.010 - 0.0 ) (25) = 5.00
1/2
+ (1/12) (25)1/2 (0.000 / 0.005)
= 1.3 [11 + 3.84 + 0.00 ]
= 19.29
Page 9 of 11
page 10/11
Ref. Calculation Output
CRACKING
7.3 CRACKING
Table 7.1N Limitting crack width, w max = 0.3 mm
Steel stress,
Page 10 of 11
Ref.
A
B
2H20-2 2H20-5+1H20-6
800 3H20-1 1200 1200
Calculation
x
Y
Page 11 of 11
450
450
225 225
X -X Y -Y
Output