Belaria+twin+ Technical+ INM-en+ 2017 PDF
Belaria+twin+ Technical+ INM-en+ 2017 PDF
Belaria+twin+ Technical+ INM-en+ 2017 PDF
■■Description
■■Part No.
Notice Delivery
Suitable charging pumps: Compact device internally wired ready for
installation. Electrical box for wall mounting
Hoval system pump set SPS-I inside the building with built-in TopTronic® E
with interface for pump control controller
Type 0-10 V or PWM1
Belaria® Heat output
Premium pump Stratos twin A with A2W35
with IF module Stratos Ext. Off (0-10 V) type kW
Stage 1 Stage 2
See brochure «Accessories» - chapter
«Circulating pumps» (17) 10.3 17.2 7014 734
(24) 13.1 23.7 7014 735
Energy efficiency class (32) 18.6 31.6 7014 736
see Description
Notice
An energy buffer accumulator
must be provided.
■■Part No.
Part No.
Recommended accessory:
High-efficiency pump with
continuously variable speed control
■■Part No.
+ OR
ODER
-- 1 heating circuit with mixer
Brass housing
Size Connection Flow rate
l/min
DN 10 G 1″ 2-40 6042 949
DN 32 G 1½″ 14-240 6042 950
Note
Refer to the Hoval System Technology Further information
to find which functions and hydraulic see “Controls” - “Hoval TopTronic® E
arrangements can be implemented. module expansions” chapter
■■Part No.
TopTronic® E sensors
AF/2P/K Outdoor sensor 2055 889
TF/2P/5/6T Immersion sensor, L = 5.0 m 2055 888
ALF/2P/4/T Contact sensor, L = 4.0 m 2056 775
TF/1.1P/2.5S/6T Collector sensor, L = 2.5 m 2056 776
System housing
System housing 182 mm 6038 551
System housing 254 mm 6038 552
Further information
see “Controls”
■■Part No.
Silt trap
Casing made of brass, PN 16
Max. operating temperature 110 °C
Sieve made of stainless steel,
size of mesh 0.5 mm
DN 25-1″ 2046 978
DN 32-1¼″ 2046 980
DN 40-1½″ 2046 982
DN 50-2″ 2046 984
■■Part No.
■■Part No.
Part No.
Service
Commissioning
■■Technical data
1
kW = incl. defrosting loss
■■Technical data
1
kW = incl. defrosting loss
■■Technical data
65
Flow temperature
Vorlauftemperatur °C
(°C)
50
35
25
-25 -20 2 30 42
Outside temperature
Aussentemperatur °C
(°C)
40
Vorlauftemperatur (°C)
Flow temperature °C
22
10
7
15 20 42
Outside temperature °C(°C)
Aussentemperatur
■■Technical data
Belaria® twin A, Sound pressure level Distance Sound pressure level Sound pressure level
Belaria® twin AR outside free installation on facade
Type dB(A) m dB(A) dB(A)
(17) 61.0 1 52.0 55.0
5 38.0 41.0
(24) 64.0 1 55.0 58.0
5 41.0 44.0
(32) 70.0 1 60.0 63.0
5 46.0 49.0
Information on sound levels applies to whisper mode. Values increase by + 4 dB(A) in normal operation
■■Technical data
Performance data - heating
50 6.00
5.50
45
5.00
40
4.50
35 4.00
Qh (kW)
30 3.50
COP
25 3.00
2.50
20
2.00
15
1.50
10
1.00
5 0.50
0 0.00
-20 -15 -10 -7 -2 2 7 10 12 15 20 -20 -15 -10 -7 -2 2 7 10 12 15 20
tQ (°C) tQ (°C)
Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32) Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32)
Heat output - tVL 45 °C Output rating - tVL 45 °C
Heizleistung Belaria® twin A/AR 45 °C COP Belaria® twin A/AR 45 °C
50 5.50
45 5.00
40 4.50
4.00
35
3.50
30
3.00
COP
Qh (kW)
25
2.50
20
2.00
15
1.50
10 1.00
5 0.50
0 0.00
-20 -15 -10 -7 -2 2 7 10 12 15 20 -20 -15 -10 -7 -2 2 7 10 12 15 20
tQ (°C) tQ (°C)
Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32) Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32)
Heat output - tVL 55 °C Output rating - tVL 55 °C
Heizleistung Belaria® twin A/AR 55 °C COP Belaria® twin A/AR 55 °C
50 4.00
45
3.50
40
3.00
35
2.50
30
Qh (kW)
25 2.00
COP
20
1.50
15
1.00
10
5 0.50
0 0.00
-7 -2 2 7 10 12 15 20 -7 -2 2 7 10 12 15 20
tQ (°C) tQ (°C)
Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32) Belaria® twin A/AR (17) Belaria® twin A/AR (24) Belaria® twin A/AR (32)
■■Technical data
Performance data - heating
■■Technical data
Performance data - cooling
5.00
35
4.50
30 4.00
25 3.50
Qk (kW)
3.00
EER
20
2.50
15 2.00
1.50
10
1.00
5
0.50
0 0.00
15 20 25 30 35 42 15 20 25 30 35 42
tQ (°C) tQ (°C)
Belaria® twin AR (17) Belaria® twin AR (24) Belaria® twin AR (32) Datenreihen1 Datenreihen2 Datenreihen3
Cooling capacity - tVL 13 °C Output rating - tVL 13 °C
Kühlleistung Belaria® twin AR EER Belaria® twin AR 13 °C
50 7.50
7.00
45
6.50
40 6.00
5.50
35
5.00
30 4.50
Qk (kW)
4.00
EER
25
3.50
20 3.00
2.50
15
2.00
10 1.50
1.00
5
0.50
0 0.00
15 20 25 30 35 42 15 20 25 30 35 42
tQ (°C) tQ (°C)
Datenreihen1 Datenreihen2 Datenreihen3 Belaria® twin AR (17) Belaria® twin AR (24) Belaria® twin AR (32)
30 4.00
EER
25 3.50
3.00
20
2.50
15 2.00
10 1.50
1.00
5
0.50
0 0.00
15 20 25 30 35 42 15 20 25 30 35 42
tQ (°C) tQ (°C)
Belaria® twin AR (17) Belaria® twin AR (24) Belaria® twin AR (32) Belaria® twin AR (17) Belaria® twin AR (24) Belaria® twin AR (32)
■■Technical data
Performance data - cooling
■■Dimensions
1195
(1923) (897,3)
(1923) (897,3)
Space requirement for Hoval Belaria® twin A (17-32), Belaria® twin AR (17-32)
(Dimensions in mm)
> 600
> 200 > 1000
925 1 2
1950
> 2000
Bedienungs-
Operation andund
main-
Wartungsfläche
tenance surface
■■Dimensions
607
390
67
45
1 2
1 Condensate drain (Rp 1″)
200 200 with electric trace heating
925
Concrete base
■■Dimensions
Configuration and connection diagram Belaria® twin A (17-32), Belaria® twin AR (17-32)
2 min. 200 mm
7
230 V
800 mm
400 V
6
3 4 5
9 8
Options
CP pump ON/OFF 230 V/2-pole/2 x 1.5 mm2
(does not apply for pump control 0-10 V)
Fault contact for PLC 230 V/2-pole/2 x 1.5 mm2
Flow rate meter 230 V/2-pole/2 x 1.5 mm2
Electricity meter 230 V/2-pole/2 x 1.5 mm2
USB cable for line recorder
USB 2.0 extension cable active
9 Empty tube for hydraulic connections outdoor unit The piping from the boilerhouse to the heat
Heating flow (17) R 1¼″/(24,32) R 1½″ pump must be configured by the installer.
Heating return (17) R 1¼″/(24,32) R 1½″ Connecting pipes are not included.
■■Dimensions
Electrical box for Hoval Belaria® twin A (17-32), Belaria® twin AR (17-32)
(Dimensions in mm)
■■Description
TopTronic® E controller
■■Part No.
Notice
An energy buffer accumulator
must be provided.
Accessories
Recommended accessory:
High-efficiency pump with
continuously variable speed control
■■Part No.
+
incl. fitting accessories
OR
ODER 1x contact sensor ALF/2P/4/T L = 4.0 m
Note
The supplementary plug set may have
to be ordered to implement functions
differing from the standard!
Note
The flow rate sensor set
must be ordered as well.
Further information
see “Controls” - “Hoval TopTronic® E
module expansions” chapter
Note
Refer to the Hoval System Technology
to find which functions and hydraulic
arrangements can be implemented.
■■Part No.
TopTronic® E sensors
AF/2P/K Outdoor sensor 2055 889
TF/2P/5/6T Immersion sensor, L = 5.0 m 2055 888
ALF/2P/4/T Contact sensor, L = 4.0 m 2056 775
TF/1.1P/2.5S/6T Collector sensor, L = 2.5 m 2056 776
System housing
System housing 182 mm 6038 551
System housing 254 mm 6038 552
Further information
see “Controls”
■■Part No.
■■Part No.
■■Technical data
1)
The sound power levels apply in whisper mode.
The values increase by +6 dB(A) in full-load operation or +4 dB(A) in partial load operation.
■■Technical data
65
62
Vorlauftemperatur
Flow °C
temperature(°C)
35
25
-25 -20 2 30 42
Outdoor temperature(°C)
Aussentemperatur °C
Cooling
40
Flow temperature
Vorlauftemperatur (°C) °C
22
10
7
15 20 42
Outdoor temperature
Aussentemperatur (°C) °C
■■Technical data
40
Sound pressure level in relation to the sound power
device/outlet
Gerät/Auslass
36
gemessenen Schallleistungspegel LWAeq [dB(A)]
32
the
28
auf denatam
24
measured
20
bezogen
16
LWAeq [dB(A)]
Schalldruckpegel
12
4
level
0
1 2 4 5 6 8 10 12 15 20 30
Distance fromvon
Abstand theder
sound source(m)
Schallquelle (m)
Richtfaktor Q=2 Richtfaktor Q=4 Richtfaktor Q=8
Example 1:
The sound pressure level of the Belaria® dual AR (60) should be measured at a distance of 5 m if it is installed on a facade.
Sound power level - Sound pressure level reduction (5 m) = Sound pressure level (5 m)
72.0 dB(A) 1) - 19 dB(A) = 53.0 dB(A) 1)
The sound pressure level of the Belaria® dual AR (60) should be measured at a distance of 10 m if it is installed on a facade.
Sound power level - Sound pressure level reduction (10 m) = Sound pressure level (10 m)
72.0 dB(A) 1) - 25 dB(A) = 47.0 dB(A) 1)
1)
The sound power levels apply in whisper mode.
The values increase by +6 dB(A) in full-load operation or +4 dB(A) in partial load operation.
■■Technical data
Performance data – heating
100
5
90
80
4
70
Qh (kW)
COP
60 3
50
2
40
30
1
20
10 0
-20 -15 -7 2 7 10 12 15 20 -20 -15 -7 2 7 10 12 15 20
tQ (°C) tQ (°C)
100
5
90
80
4
70
Qh (kW)
COP
60 3
50
2
40
30
1
20
10 0
-20 -15 -7 2 7 10 12 15 20 -20 -15 -7 2 7 10 12 15 20
tQ (°C) tQ (°C)
■■Technical data
Performance data – heating
■■Technical data
Performance data – cooling
90
5
80
4
70
Qk (kW)
EER
60 3
50
2
40
1
30
20 0
15 20 25 30 35 42 15 20 25 30 35 42
tQ (°C) tQ (°C)
Partial load
90
5
80
4
70
Qk (kW)
EER
60 3
50
2
40
1
30
20 0
15 20 25 30 35 42 15 20 25 30 35 42
tQ (°C) tQ (°C)
■■Technical data
Performance data – cooling
■■Dimensions
1500
3272 895
536
570 kg 310 kg
■■Dimensions
Space requirements
(Dimensions in mm)
> 800
> 200 >1000
914 1 2
1 Condensate drain with elec. auxiliary heating
2 Hydraulic and electrical connection
3272 Foot Ø 100 mm
> 2000
Operatingund
Bedienungs- and
maintenance area
Wartungsfläche
> 2000
>1000
>2000 >2000
Connections
Anschlüsse
■■Dimensions
Base design
(Dimensions in mm)
1354 606
312 183
55
130
90
163
1
2
200 200
914
720
3040
3260 The condensate drain is located on the rear
3272 (suction side).
Concrete base
■■Dimensions
2 min.
200 mm
7
230 V
800 mm
400 V
6
3 4 5
9 8
■■Dimensions