Give Your Motor A Health Check With The E3: Electronic Motor Protection Relays E3 and E3 Plus
Give Your Motor A Health Check With The E3: Electronic Motor Protection Relays E3 and E3 Plus
Give Your Motor A Health Check With The E3: Electronic Motor Protection Relays E3 and E3 Plus
Protection Relays
E3 and E3 Plus
Give your
motor a health
check with
the E3
Complete Automation is the solution from Rockwell Automation, that keeps
you ahead of changing markets. Our core competence is supplying solutions
to ensure our customers are successful.
2
See how the E3
range can increase
the productivity
of your application
Comprehensive protective functions integrated in
one compact device
• You can now increase the performance, operational reliability and
efficiency of your automated systems with the Electronic Motor
Protection Relay E3, because the protection, warning, and
diagnostic functions are integrated in a single compact device.
• Utilising the most advanced semiconductor technology allows
integration of many functions into a very compact housing. Minimal
space requirements and the possibility of direct connection to the
relevent contactor, combined with high functionality leads to
lower installation and operational costs.
TM
3
Busbar for direct contactor
mounting LED display
triggering/warning
DeviceNet connection
Control terminal
p to 45A)
45 mm wide (u
Only
4
Economic Motor Management
thanks to innovative technology and
compact dimensions
ControlNet
DeviceNet
6
You get more out of your installation with
communication over DeviceNet
Monitor your motor over DeviceNet and improve
the performance of the installation
• The Electronic Motor Protection Relays E3 provide important
information about the motor operating performance and the
installation over DeviceNet.
• Prewarning of failures can be initiated to avoid unplanned
operation break down.
7
Starter 11 kW 23 A / 400 V AC
Coordination Type 2
8
Intelligent, compact and high performance
starters from Rockwell Automation
Simple and fast starter assembly
• The E3 fits perfectly to the Allen Bradley contactor
range and are interlocked with the yellow connection wedge
to ensure mechanical reliability.
• Further connection modules are available for fast and error
free connection of the contactor and the circuit breaker.
Programming on site
• The E3 device can be programmed via a hand held programming
device. This unit can also be used in conjunction with an
adapter to allow the device to installed in the front
of a control panel, such as an MCC cubicle.
9
E3 and E3 Plus
complete the pioneer
Modular Control System MCS
10
Bulletin 193-EC
Motor Protection
Bulletin 193-EC
Electronic Motor Protection Relays
E3 and E3 Plus
• Programmable Trip and Warnings Settings
• Adjustable Trip Class (5…30)
• PTC Thermistor Input (E3 Plus)
• Low-Level Ground (Earth) Fault Protection (E3
Plus)
• Ground Fault Range 1…5 A
• Integrated I/O’s (additional to Tripping Relays)
• E3: 2 Inputs / 1 Output
• E3 Plus: 4 Inputs / 2 Outputs
• Test/Reset Button
• LED Indicators
• Diagnostic Functions (History of Last 5 Trips)
• DeviceNet™ Communication
Table of Contents
Description Page Description Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Description
The E3 Overload Relay is a multi-function, solid-state microprocessor-based electronic overload
relay for the protection of single- or three-phase squirrel-cage induction motors. In addition to Your order must include:
providing ambient compensated overload protection, the E3 Overload Relay also includes
advanced features such as warning diagnostics, variable frequency and true RMS current • Cat. No. of the overload relay selected.
sensing, I/O capabilities, and direct DeviceNet connestivity. The E3 Plus Overload Relay offers
• If required, Cat. No. of any accessories.
the added features of zero sequence (core balance) ground fault protection, PTC thermistor
input, and additional I/O capabilites.
Conformity to Standards: Protective / Warning Functions:
IEC 947-4 • Thermal overload
CE • Underload
Rockwell Automation 11
Bulletin 193-EC
Motor Protection
Product Overview
12 Rockwell Automation
Bulletin 193-EC
Motor Protection
Product Overview
Current Monitoring Functions Test: The trip relay contact will open if the E3 Overload Relay is in
The E3 Overload Relay allows the user to monitor the following an un-tripped condition and the Test/Reset button is pressed.
operational data over the DeviceNet network:
• Individual phase currents (in amperes) Reset: The trip relay contact will close if the E3 Overload Relay is
• Individual phase currents (as a percentage of motor full load in a tripped condition, supply voltage is present, and the Test/Reset
current) button is pressed.
• Average current (in amperes)
• Average current (as a percentage of motor full load current) Single / Three-Phase Operation
• Percentage of thermal capacity utilized The E3 Overload Relay can be applied to three-phase as well as
• Current imbalance percentage single-phase applications. A programming parameter is provided for
• Ground fault current (E3 Plus: in amperes) selection between single- and three-phase operation. Straight-
through wiring is afforded in both cases.
Diagnostic Functions
The E3 Overload Relay allows the user to monitor the following DeviceNet Communications
diagnostic information over the DeviceNet network: The E3 Overload Relay is a Group 2 “slave only” device and supports
• Device status the following:
• Trip status • Polled I/O messaging
• Warning status • Change-of-state/cyclic messaging
• Time to an overload trip • Explicit messaging
• Time to reset after an overload trip • Group 4-Off-line node recovery messaging
• History of past five trips. • Full parameter object support
Status Indicators • Auto-baud network rate identification
• Configuration consistency value
The E3 Overload Relay provides the following LED indicators:
Rockwell Automation 13
Bulletin 193-EC
Motor Protection
Product Selection
Bulletin 193-EC1 Electronic Motor Protection Relays – Direct Contactor Mount to Contactor 100-C
• 2 Inputs
• 1 Outputs
Bulletin 193-EC2 Electronic Motor Protection Relays – Direct Contactor Mount to Contactor 100-C
• 4 Inputs
• 2 Outputs
• Built-in Ground Fault Sensor
• PTC Thermistor Input
Accessories
Description For use with Package Qty. Cat. No.
193-EC__B 193-ECPM1
193-EC__E 193-ECPM3
õ For applications requiring trip class settings greater than class 20, consult your local Rockwell Automation sales office for proper contactor
selection.
Ï For applications greater than 90 A, consult your local Rockwell Automation sales office.
ÿ The electronic motor protection relay can be mounted separately to top-hat rail EN 50 02-35.
14 Rockwell Automation
Bulletin 193-EC
Motor Protection
Specifications
Main Circuits
Terminal Cross-Sections
Terminal Type
M5 M8
Terminal Screws
Flexible-Stranded
with Ferrule 1 x 2.5…16 mm2 1 x 4…35 mm2
Torque 2.5 Nm 4 Nm
Flexible-Stranded
with Ferrule 2 x 6…10 mm2 2 x 4…25 mm2
Torque 3.4 Nm 4 Nm
Stranded/Solid
Torque 1 x 2.5…25 mm2 / 14…6 AWG 1 x 4…50 mm2 / 12…1 AWG
2.5 Nm / 22 lb-in 4 Nm / 35 lb-in
Stranded/Solid
Torque 2 x 6…16 mm2 / 10…6 AWG 1 x 4…35 mm2 / 6…2 AWG
3.4 Nm / 30 lb-in 4 Nm / 35 lb-in
Pozidriv Screwdriver Size 2 —
Slotted Screwdriver 1 x 6 mm —
Hexagon Socket Size SW — 4 mm
Rockwell Automation 15
Bulletin 193-EC
Motor Protection
Specifications
Control Circuits
UL Short-Circuit Ratings
Cat. No. High available Short-Circuit Current [kA] Maximum Voltage [V]
193-EC_B 5 600
193-EC_D 5 600
193-EC_E 5 600
16 Rockwell Automation
Bulletin 193-EC
Motor Protection
Specifications
4000
1330
550
250
20
10
-20 C TNF-20K TNF+15K
0C TNF- 5K TNF+ 5K
TNF
According to IEC 34-11-2
Control and DeviceNet Terminal Cross-Sections
Terminal Screws M3
Flexible-Stranded with
Ferrule 1 x 0.25…2.5 mm2
Torque 0.55 Nm
Flexible-Stranded with
Ferrule 2 x 0.5…0.75 mm2
Torque 0.55 Nm
Coarse-Stranded/Solid 1 x 0.2…4.0 mm2 / 24…12 AWG
Torque 0.55 Nm / 5 lb-in
Coarse-Stranded/Solid 2 x 0.2…1.5 mm2 / 24…16 AWG
Torque 0.55 Nm / 5 lb-in
Slotted Screwdriver 0.6 x 3.5 mm
Rockwell Automation 17
Bulletin 193-EC
Motor Protection
Specifications
Environmental Ratings
General
0.80 kg 1.23 kg
Approximate Weights
(1.77 lb) (2.71 lb)
Standards IEC 947, CSA C22.2 Nr.14, DIN VDE 0660, EN 60 947, UL 508, UL 1053
Approvals CE, CSA, PTB (pending), UL
õ Inhibit Time settings are used for both trip and warning functions.
Ï The FLA Setting range of 1.0…2250 A is covered by 13 frame sizes. Default values are dependent upon rating of the product.
ÿ Phase loss trip level is set at a current imbalance greater than or equal to 100 % and is not user-adjustable.
þ Stall Protection is only applicable to the motor starting sequence.
18 Rockwell Automation
Bulletin 193-EC
Motor Protection
Specifications
E3 + E3 Plus E3 + E3 Plus
Trip Class 5 Trip Class 10
cold cold
hot hot
Time [seconds]
Time [seconds]
E3 + E3 Plus E3 + E3 Plus
Trip Class 20 Trip Class 30
cold cold
hot hot
Time [seconds]
Time [seconds]
Rockwell Automation 19
Bulletin 193-EC
Motor Protection
Specifications
Single-Phase Three-phase
A1 1 3 5 A1 1 3 5
K1 K1
A2 2 4 6 A2 2 4 6
T1 T2 T3 T1 T2 T3
M M
L1
13
E3
Out A
14
95
E3
Trip Relay õ
96
A1
A2
N
ÿ õContact shown with supply voltage applied
20 Rockwell Automation
Bulletin 193-EC
Motor Protection
Specifications
shield
shield
white
black
blue
red
Rockwell Automation 21
Bulletin 193-EC
Motor Protection
Approximate Dimensions
A H J
D2 øD
D1
E2
B
B1
E1 C
E3 + E3 Plus
22 Rockwell Automation
Bulletin 193-EC
Motor Protection
Approximate Dimensions
Approximate dimensions are shown in mm (inches). Dimensions are not to be used for manufacturing purposes.
Panel Mount Adapter (For Use With Cat. No. 193-EC_ _B)
Panel Mount Adapter (For Use With Cat. No. 193-EC_ _D)
Rockwell Automation 23
Bulletin 193-EC
Motor Protection
Approximate Dimensions
Approximate dimensions are shown in mm (inches). Dimensions are not to be used for manufacturing purposes.
Panel Mount Adapter (For Use With Cat. No. 193-EC_ _E)
24 Rockwell Automation
Copy!
Order
Pos. Pcs. Name/Type Order Number
Bulletin 193-EC
Motor Protection
Notes
26 Rockwell Automation
DeviceNet officially accepted
as a European standard
The European Committee for electrotechnical standardization The ODVA is represented world wide. DeviceNet, as open
(CENELEC) has officially passed DeviceNet as a European communication network, connects devices on the installation
standard. The new standard has the title EN 50325 “Industrial level such as sensors, push button switches, motor starters and
communications subsystem based on ISO 11898 (CAN) for drives with control systems.
controller-device interfaces”. DeviceNet has gained major
approval among the member states. You find further information about DeviceNet under
http://www.odva.org
The conformity with EN 50325, the availability of DeviceNet
devices and solutions of more than 300 ODVA members as well
as the great customer satisfaction promise a furthermore high
growth rate for the future.
27
Rockwell Automation
More than 500'000 possibilities
to improve automation systems
Controls
Integrated networks
Software
Sensor technology
Human-machine interface
System solutions
Industrial solutions
Technology partner