Taylor Aparat Za Sladoled

Download as pdf or txt
Download as pdf or txt
You are on page 1of 80

Models C708 & C716

Heat Treatment
Soft Serve Freezer

Operating Instructions

059061--M
6/17/08
Complete this page for quick reference when service is required:

Taylor Distributor:

Address:

Phone:

Service:

Parts:

Date of Installation:

Information found on the data label:

Model Number:

Serial Number:

Electrical Specs: Voltage Cycle

Phase

Maximum Fuse Size: A

Minimum Wire Ampacity: A

E January, 2005 Taylor


All rights reserved.
059061--M

Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
The word Taylor and the Crown design
are registered trademarks in the United States 750 N. Blackhawk Blvd.
of America and certain other countries. Rockton, IL 61072
Table of Contents

Section 1 To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


Installer Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Air Cooled Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Water Connections (Water Cooled Units Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Beater Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Section 2 To the Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Compressor Warranty Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Section 3 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Section 4 Operator Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7


Model C708 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Model C716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Model C708 Single Spout Door and Beater Assembly . . . . . . . . . . . . . . . . . . . . . . 9
Model C716 Door and Beater Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
X57029-XX Pump A. - Mix Simplified (Model C708) . . . . . . . . . . . . . . . . . . . . . . . . 11
X57029-XX Pump A. - Mix Simplified (Model C716) . . . . . . . . . . . . . . . . . . . . . . . . 12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Brush Kit Assembly X44127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Section 5 Important: To the Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Operating Screen Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Freezer Locks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Manager's Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Section 6 Operating Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Freezing Cylinder Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Freezer Door Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Mix Pump Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Models C708 & C716 Table of Contents


Table of Contents - Page 2

Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Daily Closing Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Daily Opening Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Manual Brush Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Draining Product From The Freezing Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Rinsing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Hopper Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Brush Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Section 7 Important: Operator Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
During Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Troubleshooting Bacterial Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Regular Maintenance Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Winter Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Section 8 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Section 9 Parts Replacement Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Section 10 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53


Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Note: Continuing research results in steady improvements; therefore, information


in this manual is subject to change without notice.

E January, 2005 Taylor


All rights reserved.
059061-M

Taylor Company
The word Taylor and the Crown design
a division of Carrier Commercial Refrigeration, Inc.
are registered trademarks in the United States 750 N. Blackhawk Blvd.
of America and certain other countries. Rockton, IL 61072

Table of Contents Models C708 & C716


Section 1 To the Installer

The following are general installation instructions.


For complete installation details, please see the
check out card. This unit has many sharp edges that can
cause severe injuries.

Installer Safety

In all areas of the world, equipment should Site Preparation


be installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions. Review the area the unit is to be installed in before
uncrating the unit making sure that all possible
Care should be taken to ensure that all basic safety
hazards the user or equipment may come into have
practices are followed during the installation and
been addressed.
servicing activities related to the installation and
service of Taylor equipment.
For Indoor Use Only: This unit is designed to
S Only authorized Taylor service personnel operate indoors, under normal ambient
should perform installation and repairs on temperatures of 70_-75_F (21_-24_C). The freezer
the equipment. has successfully performed in high ambient
S Authorized service personnel should consult temperatures of 104_(40_C) at reduced capacities.
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation This unit must NOT be installed in an area
or repairs. where a water jet or hose can be used. NEVER use
S Authorized service personnel must ensure a water jet or hose to rinse or clean the unit. Failure
that the proper PPE is available and worn to follow this instruction may result in electrocution.
when required during installation and
service.
S Authorized service personnel must remove
all metal jewelry, rings, and watches before This unit must be installed on a level surface
working on electrical equipment. to avoid the hazard of tipping. Extreme care should
be taken in moving this equipment for any reason.
Two or more persons are required to safely move
this unit. Failure to comply may result in personal
The main power supply(s) to the freezer injury or equipment damage.
must be disconnected prior to performing any
repairs. Failure to follow this instruction may result in
personal injury or death from electrical shock or Uncrate the unit and inspect it for damage. Report
hazardous moving parts as well as poor any damage to your Taylor Distributor.
performance or damage to the equipment.
This piece of equipment is made in the USA and has
Note: All repairs must be performed by an USA sizes of hardware. All metric conversions are
authorized Taylor Service Technician. approximate and vary in size.

081208

Models C708 & C716 1 To the Installer


Air Cooled Units Electrical Connections
In the United States, this equipment is intended to
be installed in accordance with the National
DO NOT obstruct air intake and discharge openings: Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
Model C708: Requires a minimum of 6” (152 mm) of safeguarding of persons and property from hazards
clearance on both sides and 0” in the rear of the arising from the use of electricity. This code contains
unit. provisions considered necessary for safety. In all
other areas of the world, equipment should be
Model C716: Requires a minimum of 3” (76 mm) of
installed in accordance with the existing local codes.
clearance on all sides. Install the deflector provided
Please contact your local authorities.
to prevent recirculation of warm air.

This will allow for adequate air flow across the FOLLOW YOUR LOCAL ELECTRICAL CODES!
condensers. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the Each freezer requires one power supply for each
compressors. data label. Check the data label on the freezer for
fuse, circuit ampacity and electrical specifications.
Refer to the wiring diagram provided inside of the
electrical box, for proper power connections.

CAUTION: THIS EQUIPMENT MUST BE


Water Connections PROPERLY GROUNDED! FAILURE TO DO SO
(Water Cooled Units Only) CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!

An adequate cold water supply must be provided


This unit is provided with an equipotential
with a hand shut-off valve. On the underside of the
grounding lug that is to be properly attached to the
base pan or on the right side, two 3/8” I.P.S. water
rear of the frame by the authorized installer. The
connections for inlet and outlet are provided for easy
installation location is marked by the equipotential
hook-up. 1/2” inside diameter water lines should be
bonding symbol (5021 of IEC 60417-1) on both the
connected to the machine. (Flexible lines are
removable panel and the equipments frame.
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install
a water strainer to prevent foreign substances from
clogging the automatic water valve. There will be
only one water “in” and one water “out” connection. S Stationary appliances which are not
DO NOT install a hand shut-off valve on the water equipped with a power cord and a plug or
“out” line! Water should always flow in this order: another device to disconnect the appliance
first, through the automatic water valve; second, from the power source must have an all-pole
through the condenser; and third, through the outlet disconnecting device with a contact gap of
fitting to an open trap drain. at least 3mm installed in the external
installation.
S Appliances that are permanently connected
to fixed wiring and for which leakage
A back flow prevention device is currents may exceed 10 mA, particularly
required on the incoming water connection side. when disconnected or not used for long
Please refer to the applicable National, State, and periods, or during initial installation, shall
local codes for determining the proper configuration. have protective devices such as a GFI, to

080912

To the Installer 2 Models C708 & C716


protect against the leakage of current, Refrigerant
installed by the authorized personnel to the
local codes.
S Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or In consideration of our environment, Taylor
other equivalent synthetic proudly uses only earth friendly HFC refrigerants.
elastomer-sheathed cord (Code designation The HFC refrigerant used in this unit is R404A. This
60245 IEC 57) installed with the proper cord refrigerant is generally considered non-toxic and
anchorage to relieve conductors from strain, non-flammable, with an Ozone Depleting Potential
including twisting, at the terminals and (ODP) of zero (0).
protect the insulation of the conductors from
However, any gas under pressure is potentially
abrasion.
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.

Beater Rotation
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
Beater rotation must be clockwise as viewed apply ice packs and contact a physician
looking into the freezing cylinder. immediately.

Note: The following procedures must be performed


by an authorized Taylor service technician. Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
To correct rotation on a three-phase unit, recycling, and reclaiming systems. If you have any
interchange any two incoming power supply lines at questions regarding these laws, please contact the
freezer main terminal block only. factory Service Department.

To correct rotation on a single-phase unit, change


the leads inside the beater motor. (Follow diagram WARNING: R404A refrigerant used in
printed on motor.) conjunction with polyolester oils is extremely
moisture absorbent. When opening a refrigeration
Electrical connections are made directly to the system, the maximum time the system is open must
terminal block provided in the main control box, not exceed 15 minutes. Cap all open tubing to
located: C708 - behind the rear panel. prevent humid air or water from being absorbed by
C716 - behind the lower front panel. the oil.

080912

Models C708 & C716 3 To the Installer


Section 2 To the Operator

Your freezers have been carefully engineered and The user is responsible for returning the product to
manufactured to give you dependable operation. the appropriate collection facility, as specified by
These units, when properly operated and cared for, your local code.
will produce a consistent quality product. Like all
mechanical products, they will require cleaning and For additional information regarding applicable local
maintenance. A minimum amount of care and laws, please contact the municipal facility and/or
attention is necessary if the operating procedures local distributor.
outlined in this manual are followed closely.
This Operator's Manual should be read before
operating or performing any maintenance on your Compressor Warranty Disclaimer
equipment.
The refrigeration compressors on this machine are
Your Taylor freezer will NOT eventually compensate
warranted for the term indicated on the warranty
for and correct any errors during the set-up or filling
card accompanying this machine. However, due to
operations. Thus, the initial assembly and priming
the Montreal Protocol and the U.S. Clean Air Act
procedures are of extreme importance. It is strongly
Amendments of 1990, many new refrigerants are
recommended that personnel responsible for the
being tested and developed, thus seeking their way
equipment's operation, both assembly and
into the service industry. Some of these new
disassembly, go through these procedures together
refrigerants are being advertised as drop-in
in order to be properly trained and to make sure that
replacements for numerous applications. It should
no confusion exists.
be noted that, in the event of ordinary service to this
In the event you should require technical assistance, machine's refrigeration system, only the refrigerant
please contact your local authorized Taylor specified on the affixed data label should be
Distributor. used. The unauthorized use of alternate refrigerants
will void your compressor warranty. It will be the
Note: Warranty is valid only if the parts are owner's responsibility to make this fact known to any
authorized Taylor parts, purchased from an technician he employs.
authorized Taylor Distributor, and the required
service work is provided by an authorized Taylor It should also be noted that Taylor does not warrant
service technician. Taylor reserves the right to deny the refrigerant used in its equipment. For example, if
warranty claims on equipment or parts if the refrigerant is lost during the course of ordinary
non-approved parts or refrigerant were installed in service to this machine, Taylor has no obligation to
the machine, system modifications were performed either supply or provide its replacement either at
beyond factory recommendations, or it is determined billable or unbillable terms. Taylor does have the
that the failure was caused by neglect or abuse. obligation to recommend a suitable replacement if
the original refrigerant is banned, obsoleted, or no
Note: Constant research results in steady longer available during the five year warranty of the
improvements; therefore, information in this compressor.
manual is subject to change without notice.
Taylor will continue to monitor the industry and test
new alternates as they are being developed. Should
a new alternate prove, through our testing, that it
If the crossed out wheeled bin symbol is would be accepted as a drop-in replacement, then
affixed to this product, it signifies that this product is the above disclaimer would become null and void.
compliant with the EU Directive as well as other To find out the current status of an alternate
similar legislation in effect after August 13, 2005. refrigerant as it relates to your compressor warranty,
Therefore, it must be collected separately after its call the local Taylor Distributor or the Taylor Factory.
use is completed, and cannot be disposed as Be prepared to provide the Model/Serial Number of
unsorted municipal waste. the unit in question.

080714

To the Operator 4 Models C708 & C716


Section 3 Safety
We at Taylor Company are concerned about the
safety of the operator when he or she comes in
contact with the freezer and its parts. Taylor has
gone to extreme efforts to design and manufacture
S DO NOT operate the freezer unless it is
built-in safety features to protect both you and the
properly grounded.
service technician. As an example, warning labels
have been attached to the freezer to further point S DO NOT operate the freezer with larger
out safety precautions to the operator. fuses than specified on the freezer data
label.
S DO NOT attempt any repairs unless the
main power supply to the freezer has been
disconnected. Contact your local authorized
IMPORTANT - Failure to adhere to the Taylor Distributor for service.
following safety precautions may result in
S Stationary appliances which are not
severe personal injury or death. Failure to
equipped with a power cord and a plug or
comply with these warnings may damage the
another device to disconnect the appliance
machine and its components. Component
from the power source must have an all-pole
damage will result in part replacement expense
disconnecting device with a contact gap of
and service repair expense.
at least 3mm installed in the external
installation.
S Appliances that are permanently connected
to fixed wiring and for which leakage
DO NOT operate the freezer without currents may exceed 10 mA, particularly
reading this Operator Manual. Failure to follow this when disconnected or not used for long
instruction may result in equipment damage, poor periods, or during initial installation, shall
freezer performance, health hazards, or personal have protective devices such as a GFI, to
injury. protect against the leakage of current,
installed by the authorized personnel to the
local codes.
S Supply cords used with this unit shall be
This unit is provided with an equipotential oil-resistant, sheathed flexible cable not
grounding lug that is to be properly attached to the lighter than ordinary polychloroprene or
rear of the frame by the authorized installer. The other equivalent synthetic
installation location is marked by the equipotential elastomer-sheathed cord (Code designation
bonding symbol (5021 of IEC 60417-1) on both the 60245 IEC 57) installed with the proper cord
removable panel and the equipments frame. anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
DO NOT use a water jet to clean or rinse Failure to follow these instructions may result in
the freezer. Failure to follow these instructions may electrocution. Contact your local authorized Taylor
result in serious electrical shock. Distributor for service.

080912

Models C708 & C716 5 Safety


This freezer must be placed on a level
surface. Failure to comply may result in personal
S DO NOT allow untrained personnel to injury or equipment damage.
operate this machine.
S DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws. Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
S DO NOT remove any internal operating
and must be followed accordingly. Please refer to
parts (example: freezer door, beater,
the cleaning section of this manual for the proper
scraper blades, etc.) unless all control procedure to clean this unit.
switches are in the OFF position.
Failure to follow these instructions may result in DO NOT obstruct air intake and discharge openings:
severe personal injury from hazardous moving parts.
C708: A minimum of 6” (152 mm) air space is
required on both sides and 0” on the rear.

This unit has many sharp edges that can C716: A minimum of 3” (76 mm) air space is
required on all sides. Install the deflector provided to
cause severe injuries.
prevent recirculation of warm air.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product Failure to follow these instructions may cause poor
and cause severe personal injury from blade freezer performance and damage to the machines.
contact.
S USE EXTREME CAUTION when removing For Indoor Use Only: This unit is designed to
the beater asssembly. The scraper blades operate indoors, under normal ambient
are very sharp. temperatures of 70_ - 75_F (21_ - 24_C). The
freezer has successfully performed in high ambient
S CAUTION-SHARP EDGES: Two people are
temperatures of 104_(40_C) at reduced capacities.
required to handle the cup/cone dispenser.
Protective gloves must be worn and the
mounting holes must NOT be used to lift or NOISE LEVEL: Airborne noise emission does not
hold the dispenser. Failure to follow this exceed 78 dB(A) when measured at a distance of
instruction can result in personal injury to 1.0 meter from the surface of the machine and at a
fingers or equipment damage. height of 1.6 meters from the floor.

080826

Safety 6 Models C708 & C716


Section 4 Operator Parts Identification
Model C708

Figure 1

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 PANEL-SIDE-LEFT 056963 9 SCREW-1/4-20X3/8 RHM-STNLS 011694
2 PAN-DRIP 11-5/8 LONG 027503 10 PANEL A-SIDE-RIGHT X57871
3 PIN-RETAINING-HOPPER CVR 043934 11 PANEL A.-FRONT-UPPER X59423
4 COVER-HOPPER *BLACK 053809-1 12 PANEL A.-FRONT-LOWER X58955
5 BLADE A.-AGITATOR X56591 13 STUD-NOSE CONE 055987
6 PUMP A.-MIX SIMPLIFIED S.S. X57029-14 14 SHELF-TRAY-DRIP 056076
7 PANEL-REAR 056077 15 TRAY-DRIP 056858
8 PAN A.-DRIP 5 1/2” LONG X56074 16 SHIELD-SPLASH 049203

Models C708 & C716 7 Operator Parts Identification


Model C716

Figure 2

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 COVER-HOPPER 053809-1 11 PANEL A.-FILTER-LOUVERED X59928
2 BLADE A.-AGITATOR X56591 12 SCREW-1/4-20 X 3/8 RHM-SS 011694
3 PANEL-REAR 059916 13 DEFLECTOR 059929
4 PAN-DRIP 7.875 059737 14 TRAY-DRIP-19-5/8 L X 4-7/8 033812
5 PUMP A.-MIX SIMPLIFIED X57029-14 15 SHIELD-SPLASH-WIRE-19-3/4 L 033813
6 PANEL-SIDE-RIGHT 059907 16 PAN-DRIP 19-1/2 LONG 035034
7 PANEL A.-FRONT X63879 17 STUD-NOSE CONE 055987
8 PANEL A.-FRONT X59836 18 PIN-RETAINING-HOPPER CVR 043934
9 PAN-DRIP 12.5 059736 19 PANEL-SIDE-LEFT 059906
10 FILTER-AIR-POLY-FLO 052779-11

061228

Operator Parts Identification 8 Models C708 & C716


Model C708 Single Spout Door and Beater Assembly

Figure 3

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 HANDLE A.-DRAW-WELDED X56246 10 SHOE-FRONT HELIX *FRONT* 050347
2 NUT-STUD-BLACK 2.563“ 058764 11 BEATER A.-3.4QT-1 PIN X46231
3 DOOR A.-W/BAFFLE X57332-SER 12 BLADE-SCRAPER-PLASTIC 046235
4 VALVE A.-DRAW X55820 13 CLIP-SCRAPER BLADE 7.00 046236
5 O-RING-DRAW VALVE-S.S. 014402 14 SHAFT-BEATER 056078
6 PIN-HANDLE-SS 055819 15 SEAL-DRIVE SHAFT 032560
7 GASKET-DOOR HT 4”-DBL 048926 16 NUT-STUD-BLACK 3.250” 058765
8 BEARING-FRONT-SHOE 050348 17 O-RING-1/4 OD X .070W 50 015872
9 SHOE-FRONT HELIX *REAR* 050346 18 SCREW-ADJUSTMT-5/16-24 056332

Models C708 & C716 9 Operator Parts Identification


Model C716 Door and Beater Assembly

Figure 4

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 HANDLE A.-DRAW-WELDED X56421-1 11 BEARING-FRONT-SHOE 050348
2 NUT-STUD-BLACK 3.250 LONG 058765 12 SHOE-FRONT HELIX *REAR* 050346
3 NUT-STUD*BLACK 2.563 LONG 058764 13 BLADE-SCRAPER-PLAS 8-1/8L 046235
4 DOOR A.-3SPT*HT*LG BAF X59923-SER 14 CLIP-SCRAPER BLADE 7.00” 046236
5 PIN-HANDLE-TWIN 059894 15 BEATER A.-3.4QT-1 PIN X46231
6 GASKET-DOOR HT 4”-DOUBLE 048926-1 16 SHAFT-BEATER 032564
7 O-RING--7/8 OD X .103W 014402 17 SEAL-DRIVE SHAFT 032560
8 VALVE A.-DRAW X59888 18 O-RING-1/4 OD X .070W 50 015872
9 VALVE A.-DRAW*CENTER X59890 19 SCREW-ADJUSTMENT-5/16-24 056332
10 SHOE-FRONT HELIX *FRONT* 050347 20 SEAL-DRAW VALVE H-RING 034698

080805

Operator Parts Identification 10 Models C708 & C716


X57029-XX Pump A. - Mix Simplified (Model C708)

Figure 5

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1-7 PUMP ASSEMBLY - MIX X57029-14* 9 PIN - COTTER 044731
SIMPLIFIED SOFT SERVE
10 SHAFT A.-DRIVE-MIX PUMP- X41947
1 CYLINDER-PUMP-HOPPER- 057943 HOPPER
SOFT SERVE
10a CRANK-DRIVE 039235
2 PIN A.-RETAINING X55450
10b SHAFT-DRIVE 041948
3 PISTON 053526
11 O-RING - DRIVE SHAFT 048632
4 O-RING 2-1/8” OD - RED 020051
12 O-RING 1-3/4 008904
5 CAP-VALVE 056874-14*
13 CLIP-MIX PUMP RETAINER 044641
6 GASKET - SIMPLIFIED PUMP 053527
VALVE 14 TUBE A.-FEED HOPPER X56521
SOFT SERVE
7 ADAPTOR - MIX INLET 054825
15 RING-CHECK .120 OD 056524
8 O-RING - 11/16 OD - RED 016132
*NOTE: THE STANDARD PUMP X57029-XX IS A -14.
OVERRUN CAN BE CHANGED HIGHER OR LOWER
BY SUBSTITUTING THE CAP (056874-XX) WITH
CAPS AVAILABLE -1 THROUGH -20. THE HIGHER
THE DASH (-) NUMBER, THE HIGHER THE
OVERRUN.

Models C708 & C716 11 Operator Parts Identification


X57029-XX Pump A. - Mix Simplified (Model C716)

Figure 6

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1-7 PUMP ASSEMBLY - MIX X57029-14* 9 PIN - COTTER 044731
SIMPLIFIED SOFT SERVE
10 SHAFT A.-DRIVE-MIX PUMP- X41947
1 CYLINDER-PUMP-HOPPER- 057943 HOPPER
SOFT SERVE
10a CRANK-DRIVE 039235
2 PIN A.-RETAINING X55450
10b SHAFT-DRIVE 041948
3 PISTON 053526
11 O-RING - DRIVE SHAFT 048632
4 O-RING 2-1/8” OD - RED 020051
12 O-RING 1-3/4 008904
5 CAP-VALVE 056874-14*
13 CLIP-MIX PUMP RETAINER 044641
6 GASKET - SIMPLIFIED PUMP 053527
VALVE 14 RING-CHECK .120 OD 056524
15 TUBE A.-FEED-LEFT X59808
7 ADAPTOR - MIX INLET 054825
16 TUBE A.-FEED-RIGHT X59809
8 O-RING - 11/16 OD - RED 016132
*NOTE: THE STANDARD PUMP X57029-XX IS -14.
OVERRUN CAN BE CHANGED HIGHER OR LOWER
BY SUBSTITUTING THE CAP (056874-XX) WITH
CAPS AVAILABLE -1 THROUGH -20. THE HIGHER
THE DASH (-) NUMBER, THE HIGHER THE
OVERRUN.

Operator Parts Identification 12 Models C708 & C716


Accessories

Figure 7

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 SANITIZER-KAY 5 CASE 125 041082 5 PAIL-MIX 10 QT. 013163
2 TOOL-O-RING REMOVAL 048260-WHT * KIT A.-TUNE-UP (C708) X56085
3 TOOL-SHAFT-DRIVE-PUMP- 057167 * KIT A.-TUNE-UP (C716) X49463-82
HOPPER
* KIT A.-PARTS TRAY (C708) X57797
4 LUBRICANT-TAYLOR HI-PERF 048232
* KIT A.-PARTS TRAY (C716) X58449
*NOT SHOWN

060629

Models C708 & C716 13 Operator Parts Identification


Brush Kit Assembly X44127

Figure 8

ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO.


1 BLACK BRISTLE BRUSH 013071 5 WHITE BRISTLE BRUSH 1/2 x 3 033059
2 DOUBLE END BRUSH 013072 6 BRUSH SET (3) 050103
3 WHITE BRISTLE BRUSH 1” x 2” 013073 7 YELLOW BRISTLE BRUSH 039719
4 WHITE BRISTLE BRUSH 014753 8 WHITE BRISTLE BRUSH 3” x 7” 023316
1-1/2” x 3”
9 PUMP SPOUT BRUSH 054068

Operator Parts Identification 14 Models C708 & C716


Section 5 Important: To the Operator

C708 C716

Figure 9

ITEM DESCRIPTION
1 POWER SWITCH
2 LIQUID CRYSTAL DISPLAY
3 KEYPADS
4 MIX OUT INDICATOR
5 STANDBY INDICATOR
6 MIX LOW INDICATOR
7 SELECT KEY
8 SERVICE MENU KEY
9 BRUSH CLEAN COUNTER
10 ARROW KEY(S)

Models C708 & C716 15 Important: To the Operator


Symbol Definitions Power Switch
When placed in the ON position, the power switch
To better communicate in the International arena, allows control panel operation.
symbols have replaced words on many of our
operator switches, function, and fault indicators. Fluorescent Display
Your Taylor equipment is designed with these The fluorescent display is located on the front
International symbols. control panel. During normal operation the display is
blank. The display is used to show menu options
and notifies the operator if a fault is detected. On
The following chart identifies the symbol definitions.
International models, the display will indicate the
temperature of the mix in the hopper.
= SELECT Indicator Lights
MIX LOW - When the MIX LOW symbol is
illuminated, the mix hopper has a low supply of mix
= UP ARROW and should be refilled as soon as possible.

MIX OUT - When the MIX OUT symbol is


illuminated, the mix hopper has been almost
= DOWN ARROW completely exhausted and has an insufficient supply
of mix to operate the freezer. At this time, the AUTO
mode is locked out and the freezer will be placed in
the STANDBY mode. To initiate the refrigeration
= AUTO system, add mix to the mix hopper and touch the
AUTO symbol . The freezer will automatically
begin operation.
= HEAT CYCLE HEAT MODE - When the HEAT MODE symbol
is illuminated, the freezer is in the process of a heat
cycle.
= WASH BRUSH CLEAN COUNTER - When the BRUSH
CLEAN COUNTER display has counted down to “1”,
the machine must be disassembled and brush
cleaned within 24 hours.
= MIX LOW
Reset Mechanism
The reset button is located in the service panel on
the left side of the C708. The reset buttons are
= MIX OUT
located in the back panel of the C716. A reset button
protects the beater motor from an overload
condition. Should an overload occur, the reset
= MENU DISPLAY mechanism will trip. To properly reset the freezer
place the power switch in the OFF position. Press
the reset button firmly. Turn the power switch to the
ON position. Touch the WASH symbol and
= MIX PUMP observe the freezer's performance.

= STANDBY WARNING: Do not use metal objects to


press the reset button. Failure to comply may
result in severe personal injury or death.

050628

Important: To the Operator 16 Models C708 & C716


If the beater motor is turning properly, touch the Operating Screen Descriptions
WASH symbol to cancel the cycle. Touch the
AUTO symbol to resume normal operation. If the The fluorescent display located in the center of the
freezer shuts down again, contact your authorized control panel is normally blank during the daily
service technician. operation of the machine. The display is activated
when the SEL symbol or the Manager's Menu is
selected. The display screen will also alert the
operator of specific faults detected by the control.
Air/Mix Pump Reset Mechanism
Note: The displays illustrated in this section are
those seen on the Models C708/C709. The Model
This reset button protects the pump from an
C716/C717 versions may vary slightly.
overload condition. Should an overload occur, the
reset mechanism will trip. To reset the pump, press
the reset button firmly.
Power Up Memory (Initializing)

The seven segment display should display “00”


WARNING: Do not use metal objects to during the initializing sequence.
press the reset button. Failure to comply may
result in severe personal injury or death. When the machine is powered, the control system
will initialize to perform a system check. The screen
will display “INITIALIZING”. There will be four types
of data the system will check: LANGUAGE,
Adjustable Draw Handle SYSTEM DATA, CONFIG DATA, and LOCKOUT
DATA.
These units feature an adjustable draw handle(s) to Language Initialization
provide the best portion control, giving a better,
consistent quality to your product and controlling The UVC platform supports multiple languages by
costs. The draw handle(s) should be adjusted to keeping specific strings in battery backed RAM.
provide a flow rate of 5 to 7-1/2 oz. (142 to 213 g.) After power-up or a CPU reset, the strings are
of product by weight per 10 seconds. To INCREASE tested to see if the language strings are present and
the flow rate, turn the screw CLOCKWISE. To not corrupted. If the strings are present and not
DECREASE the flow rate, turn the screw corrupted, initialization continues. Otherwise, the
COUNTERCLOCKWISE . (See Figure 10.) operator is prompted to select a language. While
language strings are being checked for integrity, the
following screen is displayed.
10354

Initializing
Language

+
Note: If there is a language initialization fault, the
machine will force a language selection prior to the

-
initializing sequence. The standard menu LED's
should light, as if it were in a menu. If a language
has been selected, the unit is powered down, the
machine should not ask for a language unless there
is another language initialization fault. English is the
Figure 10 factory default setting.

050628

Models C708 & C716 17 Important: To the Operator


System Data If Lockout Data is corrupted, all lockout history data
is cleared. A “LOCKOUT CRC ERR” fault is
System data is protected separately from the rest of displayed.
the data in memory. System data includes variables
that change frequently such as the mode the After the memory integrity has been tested, the
machine is in, lockout status, serving counters, fault Safety Timeout screen will be displayed.
codes, and others. While System Data is being
checked the following screen is displayed.
Heat Cycle Data

Heat cycle data is checked separately from the rest


Initializing of the data in memory. Each individual Heat Cycle
System Data Data record is monitored for corruption individually.
At the start of a heat cycle, the next Heat Cycle data
record is cleared and data for the heat cycle is
written to it. The current Heat Cycle Data is
If the System Data is corrupted, the machine is set displayed as the first heat cycle record in the HEAT
to OFF, the serving counters are set to zero, and the CYCLE DATA menu option.
faults are cleared. A “SYSTEM CRC ERR” fault is
set and displayed on the VFD. An acknowledgement The heat cycle data records are checked for integrity
(SEL key) is required. when the record is accessed, presently only through
the HEAT CYCLE DATA menu option. (For
Configuration Data additional Heat Cycle Data information,
see page 27.)
Configuration data is separate from the rest of the
data in the memory. Configuration data is
information entered through operator and service Once the system has initialized, the number of days
menus. While Configuration Data is being checked until brush cleaning is required is indicated on the
the following screen is displayed. control panel. The SAFETY TIMEOUT screen will
be displayed with the alarm on for 60 seconds or
until any control symbol is touched.

Initializing
Config Data
SAFETY TIMEOUT
ANY KEY ABORTS

If Configuration data is corrupted, all user and


service settings are set to defaults. A “CONFIG
CRC ERR” fault is set and displayed on the VFD.
The system will continue to operate in its previous
mode but according to default settings.
Power Switch OFF
Lockout Data
After the safety timeout has been completed and the
Lockout data is protected separately from the rest of
power switch is OFF, the following screen is
the data in the memory. While the Lockout Data is
displayed.
being checked, the following screen is displayed.

POWER SWITCH OFF


Initializing -=-=-=-=-=-
Lockout Data UNIT CLEANED

050628

Important: To the Operator 18 Models C708 & C716


Power Switch ON Heat Cycle
The HEAT symbol on the control panel is illuminated
When the power switch is placed in the ON position, throughout the heat treatment cycle. Two warning
the control panel touch keys become operative. The messages will be displayed on the screen. “DO NOT
fluorescent display will be either blank or indicate DRAW” will be displayed when the mix temperature
that the unit has been cleaned. is below 130°F (54.4°C).

DO NOT DRAW
UNIT CLEANED

When the temperature of the mix is above 130°F


(54.4°C) the screen will display a message
indicating that HOT PRODUCT is in the machine.

International Models Only:


HOT PRODUCT
Some International models will continuously display
the temperature of the mix hopper when the power
switch is in the ON position.

DO NOT attempt to draw product or


HOPPER 21.0 disassemble the unit during the HEAT cycle. The
product is hot and under extreme pressure.
UNIT CLEANED
In the HEAT cycle, the mix temperature in the
hopper and freezing cylinder must be raised to
151°F (66.1°C) within 90 minutes.
When the heating phase is complete, the freezer
If the control is set for international configuration, the
goes into the holding phase of the cycle. The holding
following screen will appear when the heat symbol is
phase will keep the temperature above 151°F
touched.
(66.1°C) for a minimum of 35 minutes.
The final phase of the heat treatment cycle is the
cooling phase. The freezer must cool the mix below
41°F (5°C) within 90 minutes.
ARE YOU SURE When the entire heat cycle has been completed, the
> Yes HEAT symbol will no longer be illuminated. The
No
machine will enter the STANDBY mode (STANDBY
symbol illuminates). The machine can be placed in
AUTO or left in STANDBY.
Use the up or down arrow symbol to move the
To comply with health codes, heat treatment system
cursor to “YES”. Touch the SEL symbol to
freezers must complete a heat treatment cycle
immediately start a heat cycle.
daily, and must be disassembled and brush cleaned
a minimum of every 14 days. Brush cleaning is the
Note: The machine must be in AUTO or STANDBY normal disassembly and cleaning procedure found in
and have sufficient mix in the hopper before the the Operator Manual. Failure to follow these
machine can successfully enter the HEAT mode of guidelines will cause the control to lock the freezer
operation. out of the AUTO mode.

050628

Models C708 & C716 19 Important: To the Operator


If the Heat Treatment Cycle fails, the screen will Touching the SEL symbol will indicate which
display a failure message and return the freezer to thermistor caused the Hard Lock.
the STANDBY mode.
Always comply with local guidelines for the
maximum number of days allowed between brush HOPPER THERM BAD
clean cycles.
FREEZER LOCKED

Freezer Locks If the machine has hard locked and an attempt is


made to enter AUTO, the machine will enter the
There are two types of freezer lock conditions that STANDBY mode and display the following message.
can occur: Hard Lock or Soft Lock. A Hard Lock
requires the machine be disassembled and brush
cleaned. A Soft Lock can be corrected by either
disassembling and brush cleaning the machine, or
by starting another heat treatment cycle. FREEZER LOCKED

Hardlock To restore the message that identified the reason for


the hard lock, turn the power switch OFF for five
There are two causes of a hard lock failure. The seconds and then return the power switch to the ON
freezer will hardlock if either the Brush Clean Timer position. The original message with the reason for
has elapsed or if a Thermistor Failure (Freezing the Hard Lock will be displayed.
Cylinder or Hopper) occurred during a Heat cycle.
The FREEZER LOCKED message will remain on
1. The following screen will be displayed if a Brush the display until the brush clean requirements are
Clean Cycle Time has occurred. fulfilled. The freezer must be disassembled in order
to activate the five minute timer on the display
screen. Once the timer counts down to zero, the
BRUSH CLEAN TIMEOUT lockout is cleared.
FREEZER LOCKED
CLEANING REQ'D
> BRUSH CLEAN Soft Lock
If a heat treatment cycle has not been initiated within
the last 24 hours, a soft lock failure will occur. A soft
Touching the SEL symbol will display the following
lock allows the operator to correct the cause of the
screen.
soft lock. The operator has the option of either
starting another heat cycle or brush cleaning the
machine. When a soft lock occurs, the machine will
go into the STANDBY mode. The following message
FREEZER LOCKED is displayed on the screen. The reason for the soft
lock is indicated on the second line.

NO HEAT CYCLE START


2. The following screen will display if there has REASON
been a thermistor failure (freezing cylinder or > HEAT CYCLE
hopper) during the heat treatment process. BRUSH CLEAN

SYSTEM FAULT If the reason for the soft lock has been corrected,
FREEZER LOCKED selecting HEAT CYCLE initiates a Heat Cycle
SERVICE REQ'D immediately. Selecting BRUSH CLEAN when the
> BRUSH CLEAN previous message is displayed will hard lock the
machine and brush cleaning will be necessary.

080222

Important: To the Operator 20 Models C708 & C716


Following are the variable messages for soft lock Once the freezer is unlocked by starting a heat
failures that appear on the second line of the screen. treatment cycle the HEAT symbol will illuminate and
the following message will be displayed on the
POWER SWITCH OFF Power switch was in the screen.
OFF position.
MIX OUT PRESENT There was a mix out
condition present.
AUTO OR STANDBY The machine was not in
OFF the AUTO or STANDBY DO NOT DRAW
mode.
NO HEAT CYCLE A heat treatment cycle
TRIED was not attempted in
the last 24 hours.
(AUTO HEAT TIME
If BRUSH CLEAN is selected to clear the lockout by
was advanced or a pow-
brush cleaning the machine, the FREEZER
er loss was experienced
at the time the cycle LOCKED message will remain on the display until
was to occur.) the brush clean requirements are fulfilled. The
freezer must be disassembled in order to activate
If the following screen appears, a soft lock has the five minute timer on the display screen. Once
occurred during the heat treatment cycle. the timer counts down to zero, the lockout is
cleared.

HEAT TREAT FAILURE


FREEZER LOCKED
> HEAT CYCLE
BRUSH CLEAN

FREEZER LOCKED
A soft lock can also occur any time during operation
when the hopper or freezing cylinder temperature
rises above 59°F (15°C), the temperature rises and
remains above 45°F(7°C) for more than one hour, or
the temperature rises and remains above 41°F(5°C) To restore the message that identified the reason for
for more than four hours. the soft lock, turn the power switch OFF for five
seconds, and then return the power switch to the
If a PRODUCT OVER TEMPERATURE condition ON position. The original message with the reason
occurs during operation, the following screen will for the soft lock will be displayed.
appear.

PRODUCT OVER TEMP


HEAT TREAT FAILURE
REASON
> HEAT CYCLE
> HEAT CYCLE
BRUSH CLEAN
BRUSH CLEAN

When one of these messages appears, automatic


freezer operation cannot take place until the freezer
is disassembled and brush cleaned, or has Note: A record of Heat Cycle Data and Lock Out
completed a heat treatment cycle. History can be found in the Manager's Menu.

050628

Models C708 & C716 21 Important: To the Operator


Manager's Menu Entering Access Code
With the ACCESS CODE screen on the display, use
the SEL symbol to set the first code number in the
The Manager's Menu is used to enter the operator cursor position. When the correct number is
function displays. To access the Menu, touch the selected, touch the SEL symbol to move the cursor
center of the CONE symbol on the control panel. to the next number position.
The arrow symbols, the SEL symbol and the CONE
symbol will be lit when the ACCESS CODE screen
is displayed. ENTER ACCESS CODE

8 3 0 9
__

Continue to enter the proper access code numbers


(8309) until all four numbers are displayed, then
touch the SEL symbol. The Manager's Menu list will
display on the screen, provided the correct access
code is entered.
If an incorrect number is entered for the access
code, the display will exit the Menu program when
the SEL symbol is touched.

Figure 11

In the Menu program, the arrow symbols and the


SEL symbol will function as menu keys.

UP ARROW - increases the value above the cursor


and is used to scroll upward in text displays.

DOWN ARROW - decreases the value above the


cursor and is used to scroll downward in text
displays.

SEL - advances the cursor position to the right and Figure 12


is used to select menu options.

There is a two minute time-out in effect during the Manager Menu Options
Manager's Menu. While in the Manager's Menu, if no
activity occurs within a two minute period, the Touch the ARROW symbols to move up or down
display will exit to the Main Menu. There is one through the Menu. Select a Menu option by touching
exception to this time-out, and that is the Current the SEL symbol. Exit the Menu program by selecting
Conditions Display. EXIT FROM MENU or touch the CONE symbol.
The following menu options are listed in the
Note: The machine will continue operation in the
Manager's Menu.
mode it was in when the Menu was selected.
However, the control keys will not be lit and are
EXIT FROM MENU
non-functional when the Manager's Menu is
displayed. The control keys are functional in the RESET DRAW COUNTER
Manager's Menu when the CURRENT SET CLOCK
CONDITIONS screen is displayed. (See CURRENT
CONDITIONS on page 28.) AUTO HEAT TIME

060413

Important: To the Operator 22 Models C708 & C716


AUTO START TIME
SET CLOCK
STANDBY MODE 12:01 2/21/2004
NO CHANGES ALLOWED
BRUSH CLEAN CYCLE Press Any Key
(C716 Only)
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
To change the date or time, select the SET CLOCK
LOCKOUT HISTORY option in the menu. Touch the UP arrow symbol to
HEAT CYCLE SUMMARY advance the arrow from Exit to Change, then touch
HEAT CYCLE DATA the SEL symbol to select the Change option.

SYSTEM INFORMATION
CURRENT CONDITIONS
SET CLOCK
12:01 2/21/2004
Selecting “EXIT FROM MENU” will exit the Change
Manager's Menu and the return the control panel > Exit
symbols to normal operation.

The SERVING COUNTER screen is used to check


or reset the number of servings dispensed from the Change the time by touching the UP arrow with the
machine. The SERVING COUNTER will cursor under the hour position. Move the cursor to
automatically reset to zero when the machine is the minutes position by touching the SEL symbol.
brush cleaned. Once the correct minutes are entered, touch the
SEL symbol to advance the cursor to the month.

SERVINGS COUNTER

0 SET CLOCK
> Next 12:01 2/21/2004

> Exit

Reset the SERVING COUNTER by touching the


SEL symbol to advance to the next screen. Touch
the UP arrow symbol to move the arrow (>) to YES
and touch the SEL symbol. The servings counter will Enter the correct month, day, and year. Then touch
reset to zero and exit back to the Manager's Menu. the SEL symbol to advance to the DAYLIGHT
SAVING TIME screen.

RESET DRAW COUNTER


DAYLIGHT SAVING TIME
Yes
> No ENABLED
> Enable
Disable

The SET CLOCK option allows the Manager to


adjust the control clock date and time. The date and
time may only be changed after the freezer has The Daylight Saving feature, when enabled, will
been manually cleaned but before it has been automatically adjust the control clock for daylight
placed in the AUTO or STANDBY mode. The saving time. To disable the Daylight Saving Time
following message will be displayed if the SET feature, touch the DOWN arrow to move the arrow
CLOCK option is selected when the machine is not to “Disable”. Then touch the SEL symbol to save the
in a brush clean state. new setting.

080222

Models C708 & C716 23 Important: To the Operator


The AUTO HEAT TIME screen allows the Manager Enable the AUTO START TIME by touching the UP
to set the time of day in which the heat treatment arrow symbol to move the arrow up to Enable.
cycle will start. Touch the SEL symbol to advance to the next
screen.

AUTO START TIME


AUTO HEAT TIME 00:00
00:00 Change
Change > Exit
> Exit

Program the AUTO START TIME by touching the


UP arrow symbol to move the arrow to “Change”.
Touch the SEL symbol to advance to the next
To set the AUTO HEAT TIME, touch the UP arrow screen.
symbol to move the arrow to “Change”. Then touch
the SEL symbol. The screen will display the time
with the cursor under the hour position.
AUTO START TIME
00:00

AUTO HEAT TIME


00:00 Use the arrow symbols to program the AUTO
START TIME by increasing or decreasing the hour
setting above the cursor. Touch the SEL symbol to
advance the cursor and program the minutes
setting. Touch the SEL symbol to return to the
previous screen with the new time setting displayed.
Touch the SEL symbol to exit the screen and return
Touch the arrow symbols to increase or decrease to the Menu.
the hour to the desired setting. Then move the
cursor to the minutes position by touching the SEL The STANDBY option is used to manually place the
symbol. Adjust the setting for minutes. Then touch machine in the standby mode during long, no draw
the SEL symbol to save the setting and return to the periods. Select the STANDBY screen from the
AUTO HEAT TIME screen. Touch the SEL symbol Manager's Menu. Touch the SEL symbol to activate
to exit the screen and return to the Menu. Standby. Standby may also be entered by touching
the STANDBY key when not in the Manager's Menu.
Discontinue Standby operation by exiting the
The AUTO START TIME option allows the Manager Manager's Menu and select the AUTO mode.
to set the time of day at which the machine
automatically enters the AUTO mode from the
STANDBY MODE
STANDBY mode. The machine must be in the
STANDBY mode without a freezer lock condition in
order to AUTO start at the programmable time. The > EXIT
AUTO START TIME can also be Disabled and
require starting the AUTO mode manually.
The BRUSH CLEAN CYCLE option allows the
Manager to select the maximum number of days
between brush cleaning the Model C716 . The brush
AUTO START TIME clean cycle may only be changed after the freezer
DISABLED has been manually cleaned, but before it has been
Enable placed in the AUTO or STANDBY mode.
> Disable Note: This option can only be accessed through the
Service Menu for the C708.

080222

Important: To the Operator 24 Models C708 & C716


The following message will be displayed if the The FAULT DESCRIPTION display will indicate if
BRUSH CLEAN CYCLE option is selected when the there is a fault with the freezer and where the fault
machine is not in a brush clean state. occurred. When no faults are detected, the following
screen will be displayed.

BRUSH CLEAN CYCLE FAULT DESCRIPTION


No Changes Allowed NO FAULT FOUND

Press Any Key

Figure 13 Touch the SEL symbol to display the next fault


found or return to the Menu if no other faults exist.
Change the number of days between brush clean Touching the SEL symbol any time faults are
intervals by using the arrow symbols. Touch the SEL displayed will clear the faults, if corrected, upon
symbol to save the setting and exit back to the returning to the Menu screen.
Menu. The number of days displayed on the brush
Listed below are the variable messages which will
clean counter will change to the new setting.
appear, along with an explanation for the corrective
action.

BRUSH CLEAN CYCLE


NO FAULT FOUND - There was no fault found in
TIME 14 DAYS
the freezer. Nothing will appear on the screen after
this variable message appears.

BEATER OVERLOAD - Place the power switch in


the OFF position. Press the beater reset button
firmly. Place the power switch in the ON position
Figure 14 and restart in AUTO.

Always comply with local guidelines on the number HPCO COMPRESSOR - Place the power switch in
of days allowed between brush clean cycles. the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart in AUTO.
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when HOPPER THERMISTOR BAD* - Place the power
there is Mix Low or Mix Out condition. The following switch in the OFF position. Replace the hopper
screen is displayed upon selecting this option. thermistor probe.

BARREL THERMISTOR BAD* - Place the power


switch in the OFF position. Replace the barrel
MIX LEVEL AUDIBLE thermistor probe.

> Enable *Note: Three codes have been set up to assist in


Disable diagnosing bad thermistor probes. If a probe has
shorted (resistance less than 1 ohm), “SHRT” will be
displayed on the screen for its respective machine
location. If the probe is open (resistance above 1
Disable the audible tone feature by touching the megohm), “OPEN” will be displayed. If the actual
DOWN arrow symbol to move the arrow to probe environment exceeds 200 °F (93°C), the
“Disable”. Touch the SEL symbol to save the new respective screen display location will read “OVER”
setting and return to the Menu. The control panel indicating the temperature is “out of range”.
icons for Mix Low and Mix Out will illuminate as the
mix level drops in the hopper, but the audible tone COMP ON TOO LONG - The compressor run time
will be disabled. exceeded the 11 minute timer.

Models C708 & C716 25 Important: To the Operator


The LOCKOUT HISTORY screen displays a history POWER FAIL IN H/C - A power failure occurred
of the last 40 soft locks, hard locks, brush clean during the heat treatment cycle.
dates, or aborted heat cycles. Page numbers are
indicated in the upper right hand corner. Page 1 MIX LOW FAILURE - The mix level in the hopper is
always contains the most recent failure. too low for a successful heat cycle.

LOCKOUT HISTORY 1 BEATER OVLD H/C - The overload tripped for the
00/00/00 00:00 beater motor.
Reason
> Exit BRL THERM FAIL - The thermistor sensor for the
freezing cylinder failed.

The second line of the screen displays the date and HOPPER THERM FAIL - The thermistor sensor for
time a failure occurs. The third line indicates the the hopper failed.
reason for a failure, or will indicate if a successful
brush cleaning has occurred. Some failures occur
HPCO H/C - The high pressure switch opened
with multiple reasons. When this occurs, a page will
during the heat treatment cycle.
be generated for each reason.
Use the arrow symbols to advance forward or move
backward to view each screen. Listed below are the
variable messages that may appear.
Faults Occurring While in AUTO Mode

Faults Occurring Entering a Heat (L/R) HPR>41F (5C) AFTER 4 HR - The mix
Treatment Cycle temperature in the hopper was above 41°F (5°C)
more than four hours.
POWER SWITCH OFF - The power switch is OFF.
(L/R) BRL>41F (5C) AFTER 4 HR - The mix
AUTO OR STBY OFF - The control was not in the
temperature in the freezing cylinder was above 41°F
AUTO or STANDBY mode.
(5°C) more than four hours.
MIX OUT FAILURE - A Mix Out condition was
present. (L/R) HPR>41F (5C) AFTER PF - The mix
temperature in the hopper was above 41°F (5°C)
NO HEAT CYCLE TRIED - The Auto Heat Time
more than four hours following a power failure.
was set to attempt a heat cycle more than 24 hours
after the last successful heat cycle.
(L/R) BRL>41F (5C) AFTER PF - The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours following a power failure.
Faults Occurring While in Heat Mode
(L/R) HPR>45F (7C) AFTER 1 HR - The mix
HEAT MODE FAILURE - The maximum allowable temperature in the left or right hopper was above
heat mode time exceeded 90 minutes. 45_F (7_C) more than one hour.
COOL MODE FAILURE - The maximum allowable
(L/R) BRL>45F (7C) AFTER 1 HR - The mix
cool mode time exceeded 90 minutes.
temperature in the left or right barrel was above
TOTAL TIME FAILURE - The maximum allowable 45_F (7_C) more than one hour.
total heat treatment time exceeded 4 hours.
(L/R) HPR>59F (15C) - The mix temperature in the
BRUSH CLEAN TIMEOUT - The total days in
hopper exceeded 59°F (15°C).
operation exceeded the brush clean cycle setting.
POWER SWITCH OFF - The power switch was (L/R) BRL>59F (15C) - The mix temperature in the
turned OFF during the heat cycle. hopper exceeded 59°F (15°C).

050628

Important: To the Operator 26 Models C708 & C716


The HEAT CYCLE SUMMARY screen displays the PEAK = Highest temperature reading for the hopper
hours since the last heat cycle, the hours since the (h) and barrel (b) during the Heat Treatment Cycle.
product temperature was above 150_F (65.6_C),
and the number of heat cycles completed since the
last brush clean date. H: 40.9 B:26.3 L
HEAT OVER COOL PEAK
1:12 0:49 h 1:19 161.0
HEAT CYCLE SUMMARY 0:46 1:11 b 0:15 169.7
HRS SINCE HC 0
HRS SINCE 150 0
HC SINCE BC 0

H: 38.0 B:23.7 R
HEAT OVER COOL PEAK
The HEAT CYCLE DATA screen contains a record 1:09 0:52 h 1:11 161.2
of up to 366 heat treatment cycles. The most recent 0:66 1:00 b 0:11 169.9
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the month and day of the heat cycle, The HEAT time indicates the amount of time taken
the start time and end time, and the fault description. in each zone to reach 150.9°F (66.1°C). Each zone
The bottom line displays the record number and must remain above 150°F (65.6°C) for a minimum of
indicates if a power failure occurred during the heat 35 minutes.
cycle (POWER FAILURE IN HC).
Touch the UP arrow symbol to advance to the next
page or the DOWN arrow symbol to view the
HEAT TREAT CYCLE previous page. A Heat Cycle Failure message will
01/01 02:00 05:14
NO FAULT FOUND
display on the first screen if a failure occurred.
1
Listed below are variable failure code messages
which could appear on line 2.
Touch the UP arrow symbol to advance forward
through the data pages. Touch the DOWN arrow HT HEAT TIME FAILURE
symbol to reverse the page direction. Mix temperature did not rise above 151_F
(66.1_C) in less than 90 minutes.
Hopper and barrel temperature records for each side CL COOL MODE FAILURE
of the freezer are displayed in the second and third Mix temperature in the hopper and freezing
screens. The second screen shows the left side (L) cylinder did not fall below 41_F (5_C) in less
side of the freezer. than 90 minutes.
The third screen shows the right side (R) of the TT TOTAL TIME FAILURE
freezer. The heat treatment cycle must be completed
in no more than 4 hours.
The top line of these screens shows the hopper (H)
ML MIX LOW FAILURE
and barrel (B) temperatures recorded at the end of
The Heat Phase or Cool Phase time was
the Heat Treat Cycle and indicates the side (L or R)
exceeded and a mix low condition was pres-
of the freezer. ent.
The remaining lines indicate the following: MO MIX OUT FAILURE
A mix out condition was detected at the start
HEAT = Total time for the hopper (h) and barrel (b)
or during the heat cycle.
to reach 150.9°F (66.1°C).
BO BEATER OLVD IN HC
OVER = Total time the hopper (h) and barrel (b) A beater overload occurred during the heat
temperature was above 150°F (65.6°C). cycle.
COOL = Total time the hopper (h) and barrel (b) HO HPCO IN HEAT CYCLE
temperature was above 41°F (5°C) during the COOL A high pressure cut-out condition occurred
phase. during the heat cycle.

050628

Models C708 & C716 27 Important: To the Operator


PF POWER FAILURE IN HC Touch the SEL symbol to advance to the third
A power failure caused the Heat Phase, system information screen containing the model bill
Cool Phase, or Total Cycle Time to exceed of material and machine serial number. Touching the
the maximum allowed time. If a power failure SEL symbol again will return to the Menu list.
occurs, but the heat treatment cycle does
not fail, an asterisk(*) will appear on the third
line of the display. B.O.M. C70827C000
S/N K0000000
OP OPERATOR INTERRUPT
Indicates the heat cycle was aborted in the > Next
OPERATOR INTERRUPT option in the Ser-
vice Menu.
PS POWER SWITCH OFF The CURRENT CONDITIONS screen provides the
The power switch was placed into the OFF viscosity readings for the product when the machine
position during the heat cycle. is running, and the hopper and the freezing cylinder
TH THERMISTOR FAILURE temperatures for the machine.
A thermistor probe has failed.
PD PRODUCT DOOR OFF VISC 0.0
A product door is not in place or is loose. HOPPER 41.0

The SYSTEM INFORMATION is displayed on three


separate screens. The first screen contains the
control and software version installed in the
machine. CURRENT CONDITIONS is the only Menu screen
that will return the control panel keys to normal
SOFTWARE VERSION operation. The Menu symbols will not be lit when
C708 CONTROL UVC3 this option is selected but the panel touch keys are
VERSION 1.07 fully functional. Exit the CURRENT CONDITIONS
> Next screen and return to the Menu by touching the SEL
symbol.
Touch the SEL symbol to advance to the next
system information screen containing the software
language version.

Language
V2.00 English 621

> Next

081111

Important: To the Operator 28 Models C708 & C716


Section 6 Operating Procedures

The C708 stores mix in a hopper and has a 3.4 Step 3


quart (3.2 liter) capacity freezing cylinder with a Heavily lubricate the inside portion of the boot seal
single spout door. The C716 stores mix in two and also lubricate the flat end of the boot seal that
hoppers and has two 3.4 quart (3.2 liter) capacity comes in contact with the rear shell bearing.
freezing cylinders with a three spout door.
Step 4
The Model C708 has been selected to illustrate the Apply an even coat of lubricant to the shaft. DO
step-by-step operating procedures. Duplicate the NOT lubricate the hex end. (See Figure 15.)
procedures, where they apply, for the second
11269
freezing cylinder on the Model C716.
R

We begin our instructions at the point where we


enter the store in the morning and find the parts
disassembled and laid out to air dry from the
previous night's cleaning.

These opening procedures will show you how to


assemble these parts into the freezer, sanitize them,
and prime the freezer with fresh mix in preparation
to serve your first portion.

If you are disassembling the machine for the first


time or need information to get to this starting point Figure 15
in our instructions, turn to page 44, “Disassembly”,
and start there. Note: To ensure the mix does not leak out of the
back of the freezing cylinder, the middle section of
the boot seal should be convex or extend out from
the seal. If the middle section of the boot seal is
concave or extending into the middle of the seal,
Freezing Cylinder Assembly turn the seal inside out.

Step 5
Note: When lubricating parts, use an approved food Insert the beater drive shaft through the rear shell
grade lubricant (example: Taylor Lube). bearing in the freezing cylinder and engage the hex
end firmly into the drive coupling. (See Figure 16.)

MAKE SURE THE POWER SWITCH IS IN


THE “OFF” POSITION! Failure to follow this
instruction may result in severe personal injury from
hazardous moving parts.

Step 1
Before installing the beater drive shaft, lubricate the
groove on the beater drive shaft.

Step 2
Slide the beater drive shaft boot seal over the small
end of the beater drive shaft and engage into the
groove on the shaft. Figure 16

Models C708 & C716 29 Operating Procedures


Step 8
Install the beater shoes. (See Figure 19.)
USE EXTREME CAUTION when handling
the beater assembly. The scraper blades are very
sharp and may cause injury.
Step 6
Before installing the beater assembly, check the
scraper blades for any nicks or signs of wear. If any
nicks are present, or if the blades are worn, replace
both blades.
If the blades are in good condition, install the
scraper blade clips over the scraper blades. Place
the rear scraper blade over the rear holding pin on
the beater. (See Figure 17.)
11271

Figure 19

Step 9
Slide the beater assembly the rest of the way into
the freezing cylinder.

Make sure the beater assembly is in position over


the drive shaft by turning the beater slightly until the
Figure 17 beater is properly seated. When in position, the
beater will not protrude beyond the front of the
Note: Scraper blades should be replaced every 3 freezing cylinder. (See Figure 20.)
months.
Note: The hole on the scraper blade must fit
securely over the pin to prevent costly damage.
11250

Step 7
Holding the rear blade on the beater, slide it into the
freezing cylinder halfway. Install the front scraper
blade over the front holding pin. (See Figure 18.)
11249

Figure 20

Repeat these steps for the other side of the


Figure 18 Model C716.

Operating Procedures 30 Models C708 & C716


Freezer Door Assembly Step 3
Lightly lubricate the inside of the top of the freezer
The assembly of the C708 freezer door is different door valve cavity. (See Figure 23.)
from the C716 freezer door. Please follow the
appropriate instructions for your machine.

Model C708 Freezer Door Assembly


Step 1
Place the door gasket into the groove on the back of
the freezer door. Slide the front bearing over the
baffle rod so the flanged edge is against the door.
DO NOT lubricate the gasket or bearing.
(See Figure 21.)

Figure 23

Step 4
Insert the draw valve from the top, with the draw
handle slot facing forward. (See Figure 24.)
Figure 21
Step 2
Slide the three o-rings into the grooves on the draw
valve and lubricate. (See Figure 22.)
10423

Figure 22 Figure 24

Models C708 & C716 31 Operating Procedures


Model C708 Freezer Door Assembly (Cont'd.) The draw handle should be adjusted to provide a
flow rate of 5 to 7-1/2 oz. (142 g. to 213 g.) of
Step 5 product by weight per 10 seconds. To INCREASE
Insert the baffle rod through the beater in the the flow rate, turn the adjustment screw
freezing cylinder. With the door seated on the CLOCKWISE. Turn the adjustment screw
freezer studs, install the handscrews, with the longer COUNTER-CLOCKWISE to DECREASE the flow
ones on top. Tighten equally in a criss-cross pattern rate.
to insure the door is snug. (See Figure 25.)
Step 7
Slide the two drip pans into the holes in the left and
rear panels. (See Figure 31.)

Figure 25
Step 6
Slide the fork of the draw handle into the slot of the
draw valve. Secure with pivot pin. (See Figure 26.) Figure 27
Step 8
Install the front drip tray and splash shield under the
door spout. (See Figure 32.)

Figure 26
Note: The C708 features an adjustable draw handle
to provide portion control, giving a better consistent
quality to your product and controlling costs. Figure 28

Operating Procedures 32 Models C708 & C716


Model C716 Freezer Door Assembly Step 6
Insert the draw valves from the bottom until the slot
Step 1 in each draw valve comes into view.
Place the door gaskets into the grooves on the back
of the freezer door.
Step 2
Slide the front bearings over the baffle rods. The
flanged edges should be against the door. DO NOT
lubricate the gaskets or bearings.
Step 3
Insert the baffle rods through the beaters in the
freezing cylinders. With the door seated on the
freezer studs, install the handscrews, with the longer
ones on top. Tighten equally in a criss-cross pattern
to insure the door is snug.

Figure 30

Step 7
Position each draw handle with the adjustment
screw facing down. Slide the fork of each draw
handle into the slot of each draw valve, starting from
the right.

Figure 29 Step 8
Slide the pivot pin through the draw handles as the
Step 4 handles are inserted into the draw valves
Slide the three o-rings into the grooves of each
standard draw valve. Slide the H-ring and o-ring into
the grooves of the center draw valve. Lubricate the Note: This freezer features adjustable draw handles
H-ring and o-rings. to provide portion control, giving a better consistent
quality to your product and controlling costs. The
Step 5 draw handles should be adjusted to provide a flow
Lubricate the inside of the freezer door spouts, top rate of 5 to 7-1/2 oz. (142 g. to 213 g.) of product by
and bottom. weight per 10 seconds.

Models C708 & C716 33 Operating Procedures


To INCREASE the flow rate, turn the adjustment Mix Pump Assembly
screw CLOCKWISE. To DECREASE the flow rate,
turn the adjustment screw COUNTER-
CLOCKWISE. Step 1
Inspect the rubber pump parts. O-rings and gasket
Step 9 must be in 100% good condition for the pump and
Snap the design caps over the bottom of the door entire machine to operate properly. The o-rings and
spouts. gasket cannot properly serve their intended function
if nicks, cuts, or holes in the material are present.
Step 10 Replace any defective parts immediately and
Slide the two rear drip trays into the holes in the discard the old.
back panel. Slide the two drip pans into the holes in
the side panels. (See Figure 31.) Step 2
Assemble the piston. Slide the red o-ring into the
groove of the piston. DO NOT lubricate the o-ring.
(See Figure 33.)

Figure 31
Figure 33
Step 11
Install the front drip tray and splash shield under the Step 3
door spouts. (See Figure 32.) Apply a thin layer of lubricant to the inside of the
pump cylinder at the retaining pin hole end. (See
Figure 34.)

15130

LU BE

Figure 32 Figure 34

Operating Procedures 34 Models C708 & C716


Step 4 15110

Insert the piston into the retaining pin hole end of the
pump cylinder. (See Figure 35.)

15123

Figure 37
Step 7
Insert the valve body cap into the hole in the mix
inlet adapter. (See Figure 38.)
15111

Figure 35

Step 5
Assemble the valve cap. Slide the o-ring into the
groove of the valve cap. DO NOT lubricate the
o-ring. (See Figure 36.)

15109
Figure 38
Step 8
Insert the mix inlet assembly into the pump cylinder.
(See Figure 39.)
15112

Figure 36

Figure 39
Step 6
Slide the pump valve gasket into the holes on the The adapter must be positioned into the notch
cap. DO NOT lubricate the gasket. (See Figure 37.) located at the end of the pump cylinder.

Models C708 & C716 35 Operating Procedures


Step 9 Step 11
Secure the pump parts in position by sliding the Install one red o-ring on each end of the mix feed
retaining pin through the cross holes located at one tube, and thoroughly lubricate. (See Figure 42.)
end of the pump cylinder. (See Figure 40.)
15113 15132

Figure 40
Figure 42
Note: The head of the retaining pin should located
at the top of the pump when installed. Step 12
Lay the pump assembly, pump clip, cotter pin and
Step 10 agitator in the bottom of the mix hopper for
Assemble the feed tube assembly. Slide the check sanitizing. (See Figure 43.)
ring into the groove of the feed tube.
(See Figure 41.)
12166

15133

Figure 41 Figure 43

Operating Procedures 36 Models C708 & C716


Step 13 Sanitizing
Slide the large black o-ring and the two smaller
black o-rings into the grooves on the drive shaft.
Thoroughly lubricate the o-rings and shaft. DO NOT
lubricate the hex end of the shaft. (See Figure 44.) Step 1
Prepare an approved 100 PPM sanitizing solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.

Step 2
Pour the sanitizing solution over all the parts in the
bottom of the mix hopper and allow it to flow into the
freezing cylinder. (See Figure 46.)

Figure 44
Step 14
Install the hex end of the drive shaft into the drive
hub at the rear wall of the mix hopper.
(See Figure 45.)

Figure 46

Note: You have just sanitized the mix hopper and


parts; therefore, be sure your hands are clean and
sanitized before going on in these instructions.

Figure 45 Step 3
Note: For ease in installing the pump, position the While the solution is flowing into the freezing
ball crank of the drive shaft in the 3 o'clock position. cylinder, take particular care to brush-clean the mix
level sensing probe on the bottom of the hopper, the
Repeat these steps for the other side of the mix hopper, the mix inlet hole, the air/mix pump, the
Model C716. pump clip, the mix feed tube, and the locking clip.

080617

Models C708 & C716 37 Operating Procedures


Step 4 Step 8
Install the pump assembly at the rear of the mix Brush the exposed sides of the hopper.
hopper. To position the pump on the drive hub, align
the drive hole in the piston with the drive crank of
the drive shaft. Secure the pump in place by slipping Step 9
the pump clip over the collar of the pump, making Place the power switch in the ON position.
sure the clip fits into the grooves in the collar.
(See Figure 47.)
Step 10
Touch the WASH symbol . This will cause the
sanitizing solution in the freezing cylinder to be
agitated. Wait at least 5 minutes before proceeding
with these instructions.

Step 11
With a pail beneath the door spout(s), open the draw
valve and touch the PUMP symbol . Open and
close the draw valve 6 times.

Note: Momentarily open the center draw valve to


Figure 47
sanitize the center door spout (C716 only).
Step 5

Draw off the remaining sanitizing solution.


Install the pump end of the mix feed
tube and secure with the cotter pin. Failure to
follow this instruction could result in sanitizer Step 12
spraying on the operator. (See Figure 48.) Touch the WASH and PUMP symbols and
12185
close the draw valve. (See Figure 49.)

Figure 48
Step 6
Prepare another pail of approved 100 PPM sanitiz-
ing solution (examples: 2-1/2 gal. [9.5 liters] of
Kay-5R or 2 gal. [7.6 liters] of Stera-SheenR).
USE WARM WATER AND FOLLOW THE Figure 49
MANUFACTURER'S SPECIFICATIONS.
Step 7 Note: Be sure your hands are clean and
Pour the sanitizing solution into the mix hopper. sanitized before going on in these instructions.

080617

Operating Procedures 38 Models C708 & C716


Step 13 Priming
Place the agitator on the agitator drive shaft
housing. (See Figure 50.)
Note: Use only FRESH MIX when priming the
freezer.
12182

Step 1
Place an empty mix pail beneath the door spout(s).
Pour 2-1/2 gallons (9.5 liters) of FRESH mix into the
mix hopper and allow it to flow into the freezing
cylinder.

Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.

Note: Momentarily open the center draw valve to


remove sanitizer from the center door spout (C716
only).
Figure 50
Step 3
Note: If agitator should stop turning during normal When mix stops bubbling down into the freezing
operation, with sanitized hands, remove agitator cylinder, remove the cotter pin from the outlet fitting
from agitator drive shaft housing and brush clean of the mix pump. Insert the outlet end of the mix
with sanitizing solution. Install the agitator back onto feed tube into the mix inlet hole in the mix hopper.
the agitator drive shaft housing. Place the inlet end of the mix feed tube into the
outlet fitting of the mix pump. Secure with cotter pin.
Step 14
Remove the cotter pin from the pump. Install the top
end of the feed tube into the pump assembly. Place
the cotter pin in position on the outlet fitting of the
pump assembly. (See Figure 51.)

Figure 52

Step 4
Select the AUTO symbol .

Step 5
Fill the hopper with fresh mix and place the mix
Figure 51
hopper cover in position.

Repeat these steps for the other side of the Repeat these steps for the other side of the
Model C716. Model C716.

Models C708 & C716 39 Operating Procedures


Daily Closing Procedures Step 7
Prepare a small amount of an approved 100 PPM
This procedure must be performed once cleaning/sanitizing solution (example: Kay-5® or
daily! Stera-Sheen®). USE WARM WATER AND FOL-
LOW THE MANUFACTURER'S SPECIFICATIONS.
The function of the Heat Treatment Cycle is to Sanitize the agitator(s) and hopper cover(s).
destroy bacteria by raising the temperature of the
mix in the freezing cylinder and the hopper to a
specified temperature for a specified period of time, Step 8
and then bringing the temperature back down low Install the agitator(s) back onto the agitator drive
enough to retard spoilage. shaft housing(s). Replace the hopper cover(s).
The Heat Treatment Cycle will start at the time
designated in the Auto Heat Time.
IMPORTANT: If you do not install the agitator(s)
IMPORTANT: The level of mix in the hoppers correctly, the machine will fail the heat cycle and
must be high enough to cover the agitator lock out in the morning.
paddles. Note: If the BRUSH CLEAN COUNTER
display has counted down to one day, do not add
mix. The machine must be disassembled and brush Step 9
cleaned within 24 hours. Return to the freezer with a small amount of
cleaning solution. Dip the door spout brush into the
The freezer must be in the AUTO (AUTO symbol cleaning solution and brush clean the door spout(s)
illuminated) or in the STANDBY mode (STANDBY and bottom of the draw valve(s).
symbol illuminated) before the HEAT cycle may
be started.
Note: To assure sanitary conditions are maintained,
Step 1 brush each item for a total of 60 seconds, repeatedly
Remove the hopper cover(s).
dipping the brush in cleaning solution.
MAKE SURE YOUR HANDS ARE CLEAN AND (See Figure 53.)
SANITIZED BEFORE PERFORMING THESE NEXT
STEPS.
Step 2
Remove the agitator(s) from the mix hopper(s).
Step 3
Remove the design caps (C716 only).
Step 4
Take the agitator(s), hopper cover(s) and design
cap(s) to the sink for further cleaning and sanitizing.
Step 5
Rinse these parts in cool, clean water.
Step 6
Prepare a small amount of an approved 100 PPM
cleaning/sanitizing solution (example: Kay-5® or
Stera-Sheen®). USE WARM WATER AND FOL-
LOW THE MANUFACTURER'S SPECIFICATIONS.
Brush clean the agitator(s) and the hopper cover(s). Figure 53

080222

Operating Procedures 40 Models C708 & C716


Step 10
Remove, clean and reinstall all drip pans.
(See Figure 54.) DO NOT attempt to draw product or
disassemble the machine during the HEAT cycle.
The product is hot and under extreme pressure.
When the heating cycle is complete, the control will
return to the STANDBY mode. The STANDBY
symbol(s) will be illuminated.

Daily Opening Procedures


Before performing the opening procedures, check
the display panel for any error messages. Normally
the display is blank unless an operational fault has
occurred. If a fault has been detected, investigate
the cause and follow the instructions on the display
before proceeding with the opening procedures.
Figure 54 (See Failure Messages, starting on page 26.)

Step 11 Set-Up - Complete The Following


Using a clean, sanitized towel, wipe down the
freezer door, front panel, the area around the bottom Make sure your hands are clean and sanitized
of the freezer door, and any other areas that before performing these next steps.
demonstrate a build-up of either moisture or food Step 1
substance. Prepare a small amount of an approved 100 PPM
sanitizing solution (example: Kay-5® or
The heat cycle will start when the clock on the Stera-Sheen®). USE WARM WATER AND
machine reaches the AUTO HEAT TIME set in the FOLLOW THE MANUFACTURER'S
Manager's Menu (See page 24). SPECIFICATIONS.
Step 2
There are 3 phases of the heat cycle: Heating, Return to the freezer with a small amount of
Holding and Cooling. Each phase has a time limit. If sanitizing solution. Dip the door spout brush into the
any one of the three phases fail to reach the proper sanitizing solution and brush clean the door spout(s)
temperatures within the time limit, the cycle will and bottom of the draw valve(s). (See Figure 55.)
automatically abort and return to the STANDBY
mode.

A failure message will appear on the fluorescent


display to inform the operator that the machine did
not successfully complete the heat treatment cycle.
The product may not be safe to serve. The freezer
will be locked out (softlock) of the AUTO mode. The
operator will be given the option of selecting the
HEAT symbol which will begin a new heat cycle,
or touching the WASH symbol which will place
the freezer into the OFF mode to allow a brush
clean of the machine.
Figure 55
Note: Once the heating cycle has started, it cannot Note: To assure sanitary conditions are maintained,
be interrupted. The heating cycle will take a brush clean each item for a total of 60 seconds,
maximum of 4 hours to complete with full hoppers. repeatedly dipping the brush in sanitizing solution.

080222

Models C708 & C716 41 Operating Procedures


Step 3 Manual Brush Cleaning
Using a clean, sanitized towel, wipe down the
freezer door, front panel, the area around the bottom This Procedure Must Be Completed Every 14
of the freezer door, and any other areas that Days!
demonstrate a build-up of either moisture or food
substance. Install the front drip tray and splash
shield. ALWAYS FOLLOW LOCAL HEALTH CODES.

To disassemble these machines, the following items


Note: Install the design caps (C716 only). will be needed:
S Two cleaning and sanitizing pails
Step 4 S Sanitizer/Cleaner
When ready to resume normal operation, touch the S Necessary brushes (provided with freezer)
AUTO symbol . (See Figure 56.) S Single service towels

Draining Product From The


Freezing Cylinder
Step 1
With a pail beneath the door spout(s), open the draw
valve. Touch the WASH and PUMP symbols .
(See Figure 57.)

Figure 56

The control has a feature in the Manager's Menu to


enable or disable the AUTO START feature. When Figure 57
AUTO START in enabled, the machine will Note: Do not allow the pump to keep running
automatically exit the STANDBY mode and start the when the draw valve is closed. Excessive
machine in the AUTO mode at a designated time pressure will build up, causing product to spurt
each day. (See page 24.)
out when the draw valve is opened.
Step 2
Note: This procedure should be performed 15 Drain the product from the freezing cylinder and the
minutes prior to serving product. mix hopper.

Operating Procedures 42 Models C708 & C716


Step 3
When the flow of product stops, touch the WASH
and PUMP symbols , cancelling the WASH
and PUMP modes. Close the draw valve.

Step 4
Remove the locking clip, mix feed tube, pump clip
and the assembled air/mix pump.

Repeat these steps for the other side of the


Model C716.

Figure 59
Step 3
Drain all the rinse water from the door spout. Close
the draw valve and touch the WASH symbol,
Rinsing cancelling the WASH mode.
Step 4
Repeat this procedure using clean, warm water, until
Step 1 the water being discharged is clear.
Pour two gallons (7.6 liters) of cool, clean water into
the mix hopper. With the white hopper brush, scrub Repeat these steps for the other side of the
the mix hopper, mix level sensing probe and the Model C716.
outside of the agitator drive shaft housing. Using the
double ended brush, brush clean the mix inlet hole.
(See Figure 58.) Hopper Cleaning
Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 2
Pour the solution into the hopper and allow it to flow
into the freezing cylinder.
Step 3
Using the white hopper brush, clean the mix hopper,
mix level sensing probes and the outside of the
agitator drive shaft housing. Using the double ended
brush, clean the mix inlet hole. (Note: Do not brush
Figure 58
clean the mix inlet hole while the machine is in the
WASH mode.)
Note: Do not brush clean the mix inlet hole while
the machine is in the WASH mode. Step 4
Touch the WASH symbol . This will cause the
Step 2 cleaning solution in the freezing cylinder to come in
With a mix pail beneath the door spout,(s) open the contact with all areas of the freezing cylinder.
draw valve and touch the WASH symbol . Step 5
(See Figure 59.) Place an empty pail beneath the door spout(s).

080617

Models C708 & C716 43 Operating Procedures


Step 6
Open the draw valve on the freezer door and draw
off all the solution.
Step 7
Once the cleaning solution stops flowing from the
door spout, close the draw valve and touch the
WASH symbol , cancelling the WASH mode.
Repeat these steps on the other side of the
Model C716.

Disassembly
Figure 60
Note: Failure to remove the parts specified below
for brush cleaning and lubrication will result in Step 7
damage to the machine. These parts must be Remove the two small o-rings and one large o-ring
removed every 14 days or the machine will lock out from the pump drive shaft.
and will not operate.

Repeat these steps on the other side of the


Model C716.
MAKE SURE THE POWER SWITCH IS IN
THE “OFF” POSITION! Failure to follow this Step 8
instruction may result in severe personal injury from Remove the front drip tray and splash shield.
hazardous moving parts.
Step 1 Step 9
Remove the handscrews, freezer door, beater and Remove all drip pans. Take them to the sink for
scraper blades, and drive shaft with drive shaft seal cleaning. (See Figure 61.)
from the freezing cylinder.
Step 2
Remove the scraper blade clips from the scraper
blades.
Step 3
Remove the drive shaft seal from the drive shaft.
Step 4
From the pump cylinder, remove the retaining pin,
mix inlet adaptor, valve cap, pump gasket, and the
piston. Remove the o-ring from the piston and valve
cap.
Step 5
Remove the freezer door gasket, front bearing, pivot
pin, draw handle, and draw valve. Remove the three
o-rings from the draw valve. Figure 61

Note: Remove the design caps (C716 only).


Note: If the drip pans are filled with an excessive
Step 6 amount of mix, it is an indication that the drive shaft
Remove the pump drive shaft from the drive hub in seal(s), or o-ring(s) should be replaced or properly
the rear wall of the mix hopper. (See Figure 60.) lubricated.

Operating Procedures 44 Models C708 & C716


Brush Cleaning Step 4
Using the black brush, clean the drive hub opening
Step 1 in the rear wall of the mix hopper. (See Figure 63.)
Prepare an approved 100 PPM cleaning solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS. Make sure all brushes provided
with the freezer are available for brush cleaning.
Step 2
Thoroughly brush clean all disassembled parts in the
cleaning solution, making sure all lubricant and mix
film is removed. Be sure to brush all surfaces and
holes, especially the holes in the pump components
and the draw valve hole in the freezer door.
Rinse all parts with clean, warm water. Place the
parts on a clean, dry surface to air dry overnight. Figure 63
Step 3
Repeat these steps on the other side of the
Return to the freezer with a small amount of
Model C716.
cleaning solution. Using the black brush, clean the
rear shell bearing at the back of the freezing Step 5
cylinder. (See Figure 62.) Wipe all exterior surfaces of the freezer with a clean,
sanitized towel.

Figure 62

080617

Models C708 & C716 45 Operating Procedures


Section 7 Important: Operator Checklist

During Cleaning and Sanitizing j 7. Discard remaining mix from the freezer during
“Cleaning Procedures”.

ALWAYS FOLLOW LOCAL HEALTH CODES.

Cleaning and sanitizing schedules are governed Regular Maintenance Checks


by your State or local regulatory agencies and
must be followed accordingly. The following
check points should be stressed during the j 1. Replace scraper blades that are nicked or
cleaning and sanitizing operations. damaged. Before installing the beater
assembly, be certain that scraper blades are
properly attached to the helix.
CLEANING AND SANITIZING MUST BE
PERFORMED EVERY 14 DAYS. j 2. Check the rear shell bearing for signs of wear
(excessive mix leakage in rear drip pan) and
be certain it is properly cleaned.

Troubleshooting Bacterial Count j 3. Using a screwdriver and cloth towel, keep the
rear shell bearing and the female hex drive
socket clean and free of lubricant and mix
j 1. Thoroughly clean and sanitize the machine
deposits.
regularly, including complete disassembly and
brush cleaning.
j 4. Dispose of o-rings and seals if they are worn,
j 2. Use all brushes supplied for thorough torn, or fit too loosely, and replace with new
cleaning. The brushes are specially designed ones.
to reach all mix passageways.
j 3. Use the white bristle brush to clean the mix j 5. Follow all lubricating procedures as outlined in
inlet hole which extends from the mix hopper “Assembly”.
down to the rear of the freezing cylinder.
j 6. If your machine is air cooled, check the
j 4. Use the black bristle brush to thoroughly condensers for accumulation of dirt and lint.
clean the rear shell bearing located at the rear Dirty condensers will reduce the efficiency
of the freezing cylinder and the drive hub and capacity of the machine. Condensers
opening in the rear wall of the mix hopper. Be should be cleaned monthly with a soft brush.
sure there is a generous amount of cleaning Never use screwdrivers or other metal probes
solution on the brush. to clean between the fins.
Note: For machines equipped with an air
j 5. Properly prepare the cleaning and sanitizing filter, it will be necessary to vacuum clean the
solutions. Read and follow the label directions filters on a monthly schedule.
carefully. Too strong of a solution may
damage the parts and too weak of a solution
will not do an adequate job of cleaning or
sanitizing.
Caution: Always disconnect
j 6. The temperature of the mix in the mix hopper electrical power prior to cleaning the
and walk-in cooler should be below 40_F condenser. Failure to follow this instruction
(4.4_C). may result in electrocution.

050808

Important: Operator Checklist 46 Models C708 & C716


j 7. If your machine is water cooled, check the On water cooled freezers, disconnect the water
water lines for kinks or leaks. Kinks can occur supply. Relieve pressure on the spring in the water
when the machine is moved back and forth for valve. Use air pressure on the outlet side to blow out
cleaning or maintenance purposes. any water remaining in the condenser. This is
Deteriorated or cracked water lines should be extremely important. Failure to follow this
replaced only by an authorized Taylor procedure may cause severe and costly damage to
distributor. the refrigeration system.
Your local Taylor Distributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer such as
Winter Storage beater, blades, drive shaft, and freezer door, and
place them in a protected dry place. Rubber trim
parts and gaskets can be protected by wrapping
them with moisture-proof paper. All parts should be
If the place of business is to be closed during the
thoroughly cleaned of dried mix or lubrication which
winter months, it is important to protect the freezer
attract mice and other vermin.
by following certain precautions, particularly if the
building is subject to freezing conditions. It is recommended that an authorized service
technician perform winter storage draining, to insure
Disconnect the freezer from the main power source all water has been removed. This will guard against
to prevent possible electrical damage. freezing and rupturing of the components.

080222

Models C708 & C716 47 Important: Operator Checklist


Section 8 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGE


REF.
1. Soft lock message a. More than 24 hours since a. The freezer must go 20
appears on display. the last HEAT cycle. through a HEAT cycle
every 24 hours. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.
b. The power switch is in the b. The power switch must be 21
OFF position. in the ON position. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.
c. The freezer was not in the c. The freezer must be in the 21
AUTO or STANDBY mode AUTO or STANDBY
when the heat cycle was mode. The freezer must
programmed to start. now be disassembled and
brush cleaned or placed in
a heat cycle.
d. Mix out or mix low d. The level of mix in the mix 21
condition. hopper must be above the
mix low probe. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.

e. The agitator is not e. The agitator must be 40


installed. cleaned and installed
before starting the HEAT
cycle. The freezer must
now be disassembled and
brush cleaned or placed in
a heat cycle.

f. There was a power failure. f. Check fault messages and 26


product temperature.
Disassemble and brush
clean, or initiate a heat
treatment cycle.

Important: Operator Checklist 48 Models C708 & C716


PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
2. Hard lock message a. Brush clean interval a. The freezer must be 20
appears on display. exceeded. (Programmable disassembled and brush
from 2 - 14 days.) cleaned within 24 hours
when the counter
indicates one day
remaining.
b. A barrel or hopper b. Call an authorized service ---
thermistor is faulty. technician.

3. No control panel functions a. Machine is unplugged. a. Plug into wall receptacle. ---
with power switch ON.
b. Circuit breaker OFF or b. Turn the breaker ON or ---
blown fuse. replace the fuse.

4. Machine makes a a. Starved barrel. a. Remove ,clean and 34, 37, 44


squealing noise. reinstall the pump.

5. No product is being a. Low on mix. The MIX a. Add mix to the hopper. 39
dispensed. OUT light is on. Return to AUTO mode.

b. The power switch is in the b. Place the power switch to 38


OFF position. ON and select AUTO.

c. Machine not in AUTO c. Select AUTO and allow 39


mode. machine to cycle off
before drawing product.
d. Beater motor is out on d. Turn the machine off. ---
reset. The BEATER Press the reset button.
OVERLOAD message Restart the machine in
displayed. AUTO.

e. The pump motor is not e. Push the pump reset 17


running in the AUTO button. Check pump motor
mode. is operating when the
draw valve is raised.
f. Freeze-up in mix inlet f. Call an authorized service ---
hole. technician.

g. The mix pump ball crank g. Call an authorized service ---


is broken. technician.

h. Feed tube or check ring h. Make sure feed tube and 36, 39
not properly installed. rubber check ring are
properly installed.

Models C708 & C716 49 Important: Operator Checklist


PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
6. The product is too soft. a. Draw rate is set too fast. a. Adjust draw rate of 5 to 7 17
1/2 oz. (142 g. to 213 g.)
of product by weight in 10
seconds.
7. The product is too thick. a. Freezing cylinder not a. Drain the freezing cylinder 39
primed correctly. and reprime the machine.

b. Air/mix pump incorrectly b. Follow assembly 34


assembled. procedures carefully.

c. The viscosity control is set c. Call an authorized service ---


too cold. technician.

d. Freeze-up in mix inlet d. Call an authorized service ---


hole. technician.

e. Butterfat is in the pump. e. Disassemble , clean and 34, 37, 44


reinstall the pump.
8. The mix in the hopper is a. Hopper cover is not in a. Clean and sanitize hopper 40
too warm. position. cover and place in
position.
b. The agitator is not b. Clean and sanitize the 40
installed. agitator and install.

c. The hopper temperature is c. Call an authorized service ---


out of adjustment. technician.

9. The mix in the hopper is a. The hopper temperature is a. Call an authorized service ---
too cold. out of adjustment. technician.

10. Mix Low and Mix Out a. Milkstone build-up in the a. Clean hoppers thoroughly. 45
probes are not hopper.
functioning.
11. Product is collecting on a. The top o-ring on draw a. Lubricate properly or 33
top of the freezer door. valve is improperly replace the o-ring.
lubricated or worn.
12. Excessive mix leakage a. Bottom o-ring on draw a. Lubricate properly or 33
from the bottom of door valve is improperly replace the o-ring.
spout. lubricated or worn.

Important: Operator Checklist 50 Models C708 & C716


PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
13. Excessive mix leakage a. The seal on drive shaft is a. Lubricate properly or 29
into the long drip pan. improperly lubricated or replace the seal.
worn.
b. The seal is installed b. Install correctly. 29
inside-out on the drive
shaft.
c. Inadequate lubrication of c. Lubricate properly. 29
the drive shaft.
d. The drive shaft and beater d. Call an authorized service ---
assembly work forward. technician.

e. Worn rear shell bearing. e. Call an authorized service ---


technician.
f. Gear box out of alignment. f. Call an authorized service ---
technician.
14. The drive shaft is stuck in a. Mix and lubricant collected a. Brush clean the rear shell 45
the drive coupling. in drive coupling. bearing area regularly.

b. Rounded corners of drive b. Call an authorized service ---


shaft, drive coupling, or technician.
both.
c. Gear box is out of c. Call an authorized service ---
alignment. technician.

15. The freezing cylinder a. Missing or worn front a. Install or replace the front 30, 33
walls are scored. bearing and beater shoes. bearing and beater shoes.

b. Broken freezer door baffle b. Replace freezer door. 33


rod.
c. Broken beater pins. c. Replace beater assembly. 30

d. Beater assembly is bent. d. Replace beater assembly. 30

e. Gear box is out of e. Call an authorized service ---


alignment. technician.

16. The product makes a a. Draw rate is set too fast. a. Adjust draw rate of 5 to 7 17
popping sound when 1/2 oz. (142 g. to 213 g.)
drawn. of product by weight in 10
seconds.
b. Pump assembled b. Assemble and lubricate 34
incorrectly. according to instructions
in this manual.
c. Freezing cylinder not c. Drain the freezing cylinder 39
primed correctly. and reprime the machine.

Models C708 & C716 51 Important: Operator Checklist


Section 9 Parts Replacement Schedule

PART DESCRIPTION EVERY 3 MONTHS EVERY 6 MONTHS ANNUALLY

Scraper Blade X
Drive Shaft Seal X
Freezer Door Gasket X
Front Bearing X
Front Beater Shoes X
Draw Valve O-Ring X
Mix Feed Tube O-Ring X
Pump O-Ring X
Pump Valve Gasket X
Mix Feed Tube Check Ring X
Pump Drive Shaft O-Ring X
White Bristle Brush, 3” x 7” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 3” x 1/2” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 1-1/2” x 3” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 1” x 2” Inspect & Replace Minimum
if Necessary

Black Bristle Brush, 1” x 2” Inspect & Replace Minimum


if Necessary
Double-Ended Brush Inspect & Replace Minimum
if Necessary
Yellow Bristle Brush Inspect & Replace Minimum
if Necessary
Brush Set (3) Inspect & Replace Minimum
if Necessary

Parts Replacement Schedule 52 Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
ACCUMULATOR-COPPER 2"DIA 10" 047062 1 2 103
ACTUATOR A.-DRAW SWITCH X62401 1 103
ADAPTOR-MIX INLET-SS-RED 054825 1 2 103
BEARING-FRONT-SHOE 050348 1 2 000 KIT X50350

Models C708 & C716


+SHOE-FRONT HELIX *FRONT* 050347 1 2 000
+SHOE-FRONT HELIX *REAR* 050346 1 2 000
Section 10

BEARING-REAR SHELL-NICKEL 031324 1 2 000


+GUIDE-DRIP SEAL 028992 1 2 000
+NUT-BRASS BEARING 028991 1 2 000
+WASHER-BEARING LOCK 012864 1 2 000
BEATER A.-3.4QT-1 PIN-SUPPORT X46231 1 2 103
+BLADE-SCRAPER-PLASTIC 8-1/8L 046235 2 4 000
+CLIP-SCRAPER BLADE 7.00 INCH 046236 2 4 103
BELT-AX39 023874 2 000 208-230V 60HZ 1PH

53
BELT-AX40 023875 2 000 220-240V 50HZ 1PH
BELT-AX32 032769 4 000
BELT-AX33 024396 4 000 380-415V 50HZ 3N~ (4WIRE)
BLADE A.-AGITATOR *C708* X56591 1 2 103
BLOCK-TERMINAL 2P .25 SPADE 051644 1 103
BLOCK-TERMINAL 2P .2 SCREWTYPE 040321-002 1 2 103
BLOCK-TERMINAL 2P-L1,N 039421 1 103 220-240V 50HZ 1PH
BLOCK-TERMINAL 2P-L1,L2 039422 1 2 103 208-230V 60HZ 1PH
BLOCK-TERMINAL 2P L1,N 039421 1 103 220-240V 50HZ 1PH
BLOCK-TERMINAL 3P-L1,L2,L3 039423 1 2 103 208-230V 60HZ 3PH
BLOCK-TERMINAL 4P L1,L2,L3,N 039424 1 103 380-415V 50HZ
BLOCK-TERMINAL 3P 20A, 300V 051331 1 103 208-230V 60HZ 1PH / 220-240V 50HZ 1PH
BLOCK-TERMINAL 7P GREEN 024156 1 103 380-415V 50HZ / 220-240V 50HZ 1PH
BLOCK-TERMINAL 2P .25 SPADE 051644 1 103 208-230V 50&60HZ 1PH&3PH/380-415V 50HZ
BLOWER-HIGH OUTPUT-HTGS 059750-27 1 103
BOOT-VALVE-EXPANSION 050900 1 2 000 BARREL
BOOT-VALVE-EXPANSION 027137 1 000 HOPPER TXV

Parts List
Parts List

BOTTLE-WASH-PLASTIC 044818 1 000


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
BRUSH A.-PACKAGE-HT X44127 1 1 000

Parts List
BRUSH-REAR BRG 1"D X 2"LG X 013071 1 1 000
BRUSH-DBL END-PUMP & FEED TUBE 013072 1 1 000
BRUSH-DRAW VALVE 1"OD X 2"X17" 013073 1 1 000
BRUSH-DRAW VALVE 1-1/2"OD X 14" 014753 1 1 000
BRUSH-MIX PUMP BODY-3" X 7" WH 023316 1 1 000
BRUSH-1/2" DIA 033059 1 1 000
BRUSH-END-DOOR-SPOUT-SS-HT 039719 1 1 000
BRUSH-SET LVB 050103 1 1 000
BRUSH-PUMP SPOUT *MC13* 054068 1 1 000
BRUSH-SET LVB 050103 1 1 000
CABLE-RIBBON-14C-14"L SIP/SIP 040040-015 1 103 PCB TOUCH PAD DISPLAY
CABLE-RIBBON-20C-14"L-DIL/DIL 040040-040 1 2 103 J2C TO J12IF
CABLE-RIBBON-20C-17"L-DIL/DILR 040040-013 1 103
CABLE-RIBBON-20C-18"L-DIL/DILR 040040-042 1 103 J7C TO J9IF
CABLE-RIBBON-50C-10"L-DIL/DIL 040040-058 1 103

54
CABLE-RIBBON-50C-20"L-DIL/DIL 040040-011 1 103 J10C TO J2IF
CABLE-RIBBON-50C-25"L.DIL/DIL 040040-025 1 103
CABLE-USB 056785 1 1 103 PCB TOUCH PAD DISPLAY
CAP-DESIGN 1.010"ID-6 POINT 014218 3 000
CAP-VALVE BODY SS 056874-12 1 103
CAP-VALVE BODY SS 056874-16 1 103
CAPACITOR-MOTOR-AGITATOR 057525 1 2 103
CAPACITOR-RUN 440VAC 50/60HZ 059789 1 1 103
CAPACITOR-START 47-56UF/220TO 037251-34 1 2 103
CAPACITOR-RUN 40MF/440V 036049 1 2 103 220-240V 50HZ 1PH ---716-40
CAPACITOR-START 216-259UF/33 048908 2 103 220-240V 50HZ 1PH ---716-40
CASTER-4" SWV 3/4-10 STM 044106 4 103
CD-OPS TRAINING VIDEO *C708* 062069-CD 1 1 000
COMPRESSOR L64A113BBCA 048259-27E 1 2 512 S/N K7112082 & UP - 208-230V 60HZ 1PH -
BRISTOL
+CAPACITOR-RUN 25UF/440V 037431 1 2 103
+CAPACITOR-START 189-227UF/33 033044-1 1 2 103

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
+RELAY-START-COMPRESSOR 062363 1 2 103
+GROMMET-COMPRESSOR 037428 4 8 000
MOUNTING
+SLEEVE-MOUNTING-COMP. 039924 4 8 000
COMPRESSOR L63A113DBLA 048259-33 1 2 512 S/N K7112086 & UP - 208-230V 60HZ 3PH -

Models C708 & C716


BRISTOL
COMPRESSOR CS20K6E-PFV-238 057011-27 1 2 512 S/N K7109124 & PRIOR - 208-230V 60HZ 1PH
- COPELAWELD
+CAPACITOR-RUN 40MF/440V 036049 1 2 103 "
+CAPACITOR-START 189-227UF/330V 033044-1 1 2 103 "
+RELAY-START-COMPRESSOR 052401-27 1 2 103
COMPRESSOR L63A113DBLA 048259-33 1 2 512 K7112084 & UP
COMPRESSOR CS20K6E-TF5-238 057011-33 1 2 512 S/N K7109134 & PRIOR - 208-230V 60HZ 3PH
/ 220-240V 50HZ 3PH - COPELAWELD
COMPRESSOR CS20K6E-PFZ-238 057011-40 1 2 512 S/N K7066782 & PRIOR - 220-240V 50HZ 1PH
- COPELAWELD

55
+CAPACITOR-RUN 40MF/440V 036049 1 103 "
+CAPACITOR-START 216-259UF/330V 048908 1 103 "
+RELAY-START-COMPRESSOR 051957-40 1 103 "
COMPRESSOR CS20K6E-TFD-238 057011-58 1 2 512 380-415V 50HZ 3N~ (4WIRE)
CONDENSER-AC 12LX18HX3.12T-5RW 055813-1 1 103 LEFT
CONDENSER-AC 12LX18HX3.12T-5RW 055813-2 1 103 RIGHT
CONDENSER-AC 16X16 3ROW 14FPI 056944 1 103
COUPLING-DRIVE 3/4 HEX X 1-7/8 012721 1 2 103
COUPLING-3/8FS X 1/4FS 031791 2 2 103
COUPLING-3/8FS X 5/16FS 054654 1 2 103 LINE A. DISCHARGE
COVER-HOPPER *BLACK* SEE KIT A.COVER-HOPPER
DECAL-INST-CLN-DAY-HT-SS 045273 1 1 000
DECAL-INST-CLN-HT-SS 045276 1 1 000
DECAL-TROUBLESHOOT 038374 1 1 000
DEFLECTOR-BLOWER-EXHAUST 059929 1 103
DIAGRAM-WIRING *C708/C709* 057010-27 1 000 208-230V 60HZ 1PH
DIAGRAM-WIRING *C708/C709* 057010-33 1 000 208-230V 60HZ 3PH

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
DIAGRAM-WIRING *C708/C709 057010-35 1 000 220-240V 50HZ 3PH

Parts List
DIAGRAM-WIRING *C708/C709* 057010-40 1 000 220-240V 50HZ 1PH
DIAGRAM-WIRING *C708/C709 057010-58 1 000 380-415V 50HZ 3N~
DIAGRAM-WIRING *C716* 059900-27 1 000 208-230V 60HZ 1PH
DIAGRAM-WIRING *C716* 059900-33 1 000 208-230V 60HZ 3PH - 3 WIRE
DIAGRAM-WIRING *C716* 059900-40 1 000 220-240V 50HZ 1PH
DIAGRAM-WIRING *C716* 059900-58 1 000 380-415V 50HZ 3N~ (4WIRE)
DOOR A.-W/BAFFLE X57332-SER 1 103
+GASKET-DOOR HT 4"-DOUBLE 048926 1 000
+HANDLE A.-DRAW-WELDED *C708* X56742 1 103
+O-RING-1/4 OD X .070W 50 DURO 015872 1 103
+O-RING-7/8 OD X .103W 014402 3 000
+PIN-HANDLE-SS *C602* 055819 1 103
+SCREW-ADJUSTMENT-5/16-24 *602* 056332 1 103
+VALVE A.-DRAW *C602* X55820 1 000
DOOR A.-3SPT*HT*LG BAF*W/O PRG X59923-SER 1 103

56
+BEARING-FRONT-SHOE 050348 2 000
+DECAL-DOOR-3 SPOUT-TWIN TWIST 062239 1 000
+GASKET-DOOR-4"-DART 048926-1 2 000
+HANDLE A.-DRAW-WELDED *C602* X56421-1 3 103
+O-RING-1/4 OD X .070W 50 DURO 015872 3 000
+O-RING-7/8 OD X .103W 014402 8 000
+PIN-HANDLE-TWIN *C712/C717* 059894 1 103
+SCREW-ADJUSTMENT-5/16-24 *602* 056332 3 103
+SEAL-DRAW VALVE 034698 1 000
+VALVE A.-DRAW-CENTER *C716/717 X59890 1 103
+VALVE A.-DRAW-L & R *C716/717 X59888 2 103
DRYER-FILTER-HP62-3/8 X 1/4S 048901 1 000
DRYER-FILTER 3/8 X 3/8SOL HP 049154 2 000
DVD-OPS TRAIN VID *C708/C716 062069-DVD 1 1 000
EYELET-RESET BUTTON 013739 2 6 103
FASTENER-DOOR LATCH 030787 2 2 000
FASTENER-DOOR STRIKE 030788 2 2 000

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
FILTER-AIR-21.688X15.813HX.70W 052779-9 1 2 000
FILTER-AIR-POLY-FLO 052779-11 2 000
FILTER-CORCOM 6EH1 040140-001 1 1 103
GASKET-BASE PAN *C708* 056364 1 000
GEAR A.*REDUCER 4.21:1 021286-SER 1 2 212

Models C708 & C716


GUARD-POWER SWITCH 034830 1 1 103
GUIDE A.-DRIP PAN X28863 1 103
GUIDE A.-DRIP PAN-PUMP *C706* X56326 1 103 MIX PUMP BOX ASSY
GUIDE A.-DRIP PAN-MIX PUMP X48228 2 103
GUIDE A.-DRIP PAN-LEFT X59910 1 103
GUIDE A.-DRIP PAN-RIGHT X59911 1 103
GUIDE A.-DRIP PAN-CENTER X59913 1 103
HARNESS-WIRE-BEATER MOTOR 057725-27G 1 103 208-230V 60HZ 1 / 220-240V 50HZ 1
HARNESS-WIRE-BEATER MOTOR 057725-33G 1 103 208-230V 60HZ 3 / 380-415V 50HZ 3
HARNESS-WIRE-BEATER MOTOR-1PH 062053-27G 2 103 S/N K7112082 & UP - 208-230V 60HZ 1PH -
BRISTOL

57
HARNESS-WIRE-COMPRESSOR 062056-33G 2 103 S/N K7112086 & UP -208-230V 60HZ 3
HARNESS-WIRE-COMP. RIGHT*863 056103 1 103 208-230V 60HZ 3
HARNESS-WIRE-COMP. RIGHT*863 056103-G 1 103 380-415V 50HZ 3
HARNESS-WIRE-MAIN POWER *C708* 058285-27G 1 103 208-230V 60HZ 1
HARNESS-WIRE-MAIN POWER *C708* 058285-33G 1 103 208-230V 60HZ 3
HARNESS-WIRE-MAIN POWER *C708* 058285-40 1 103 220-240V 50HZ 1
HARNESS-WIRE-MAIN POWER *C708* 058285-58 1 103 380-415V 50HZ 3
HARNESS-WIRE-SOL VLV/FAN MTR 057726 1 103 208-230V 60HZ 1PH / 208-230V 60HZ 3
HARNESS-WIRE-SOL VLV/FAN MTR 057726-G 1 103 220-240V 50HZ 1 PH / 380-415V 50HZ 3
HARNESS-WIRE-THERMISTOR-PROBE 057728 1 103 208-230v 60 1&3, 220-240v 50 1, 380-415 50 3
HOUSING A.-AGITATOR *C708* X56586-03 1 2 103
BODY-AGITATOR HOUSING *C708* 056588 1 2 103
CAP-AGITATOR HOUSING *C708* 056589 1 2 103
NUT-AGITATOR BELT HOUSING *H 043574 1 2 103
MAGNET A.-AGITATOR*C708* X57341 1 2 103
MAGNET A.-AGITATOR-INNER X41733 1 2 103
SCREW-8-32X3/16 ALLEN SET 006812 1 2 000

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
BUSHING-AGITATOR MAGNET 057342 1 2 NNN

Parts List
MOTOR-AGITATOR-24VAC 50/60 HZ 050535-03 1 2 103
O-RING-1-3/8 OD X .070W 017395 1 2 000
PLATE-HOLDING-AGITATOR *C708* 056587 1 2 103
SCREW-8-32X3/16 ALLEN SET 006812 1 2 000
SCREW-4-40X1/4 SOC SS 600165 2 4 000
INTERLOCK A.-DOOR X65658 1 1 103 S/N K7085360 & UP - REPLACES 056249
FITTING DOOR INTERLOCK 065471 1 1 103
SPRING-INTERLOCK DOOR 065409 1 1 000
SWITCH-REED*DOOR INTERLOCK*6 056771 1 1 103
JACK A.-FLAVORBURST *C706* X56353 1 2 103
KIT A.-COVER-HOPPER*SINGLE*BLK X65368 1 000
COVER-HOPPER *BLACK* 053809-1 1 103
LABEL-CAUTION-AGITATOR 045191 1 000
+PIN-RETAINING-HOPPER COVER 043934 4 103
KIT A.-COVER-HOPPER*DUAL*BLK X65178 1 000

58
COVER-HOPPER *BLACK* 053809-1 2 103
LABEL-CAUTION-AGITATOR 045191 2 000
+PIN-RETAINING-HOPPER COVER 043934 2 103
KIT A.-TUNE UP *C708* X63146 1 000
KIT A.-PUMP-SIMPLIFIED SS/SH X56200-10 1 000
O-RING-1-3/4 OD X .139W 008904 1 000 DRIVE CRANK
O-RING-11/16ODX.103W-RED 016132 2 000 PUMP FEED TUBE
O-RING-2-1/8 OD X .139W-#225 020051 2 000 VALVE CAP
O-RING 1/2 ID X .139W 048632 2 000 PUMP DRIVE SHAFT
GASKET-SIMPLIFIED PUMP VALVE 053527 1 000
RING-CHECK-FEED-TUBE 056524 1 000 FEED TUBE
KIT A.-DOOR/BARREL SS C602 X56200-14 1 000
O-RING-7/8 OD X .103W 014402 3 000 DRAW VALVE
SEAL-DRIVE SHAFT 032560 1 000 DRIVE SHAFT
GASKET-DOOR HT 4"-DOUBLE 048926 1 000
SHOE-FRONT HELIX *REAR* 050346 1 000 BEATER
SHOE-FRONT HELIX *FRONT* 050347 1 000 BEATER

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
BEARING-FRONT-SHOE 050348 1 000
TOOL-O-RING REMOVAL-FREEZER 048260-WHT 1 000
KIT A.-TUNE C716 SIMPL PUMP X49463-82 1 000
KIT A.-PUMP-SIMPLIFIED SS/SHK X56200-10 2 000
O-RING-1-3/4 OD X .139W 008904 2 000

Models C708 & C716


O-RING-11/16ODX.103W-RED 016132 4 000
O-RING-2-1/8 OD X .139W-#225 020051 4 000
O-RING 1/2 ID X .139W 048632 4 000
GASKET-SIMPLIFIED PUMP VALVE 053527 2 000
RING-CHECK-FEED-TUBE 056524 2 000
KIT A.-DRAW VALVE C716 X56200-18 1 000
CAP-DESIGN 1.010"ID-6 POINT 014218 3 000
O-RING-7/8 OD X .103W 014402 8 000
SEAL-DRAW VALVE 034698 1 000
KIT A.-BARREL *TWIN SS*8784* X56200-6 1 000
SEAL-DRIVE SHAFT 032560 2 000

59
GASKET-DOOR-4"-DART 048926-1 2 000
SHOE-FRONT HELIX *REAR* 050346 2 000
SHOE-FRONT HELIX *FRONT* 050347 2 000
BEARING-FRONT-SHOE 050348 2 000
TOOL-O-RING REMOVAL-FREEZER 048260-WHT 1 000
LABEL-CAUTION-GRD-PERM-ENG/SP 032164 1 1 000
LABEL-DOOR-MOVE PART 032749 1 1 000
LABEL-RESET-MIX PMP 044452 1 1 000
LABEL-SW-POWER-OFF/ON-SYMBOLS 052632 1 1 000
LABEL-WARN-COVER 051433 4 7 000
LIP-DRIP-NOSE CONE 036435 1 000
LIP-DRIP-NOSE CONE-TWIN 036434 1 000
LUBRICANT-TAYLOR HI PERF-4 OZ 048232 1 1 000
MAN-OPER C708/C716 059061-M 1 1 000
MANIFOLD-1/2S THRU-1/4S OUT- 046688 1 2 103 LINE A.-DISCHARGE
MOTOR-1.5 HP CAPS@8&10 O'CLOCK 056865-27 1 212 208-230V 60HZ 1PH
MOTOR-1.5 HP CAPS@8&10 O'CLOCK 056865-34 1 212 220-240V 50HZ 1PH

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
MOTOR-1.5 HP 021522-27 1 212 208-230V 60HZ 1PH

Parts List
MOTOR-1.5 HP 021522-33 1 2 212 208-230V 60HZ 3PH - 3 WIRE
MOTOR-1.5 HP CAPS@10&2 O'CLOCK 021522-34 2 212 220-240V 50HZ 1PH ---716-40
MOTOR-1.5 HP 021522-35 1 212 220-240V 50HZ 3PH & 380-415V 50HZ 3N~
MOTOR A.-AGITATOR SEE - HOUSING A.-AGITATOR
MOTOR-FAN W/4 BLADE 185W 500303-27 1 103
+CAPACITOR-RUN 4.0UF/400V 500311 1 103
+GUARD-FAN 500304 1 103
MOTOR-REDUCER 32 RPM-HPR PUMPM 036955-34 1 2 212
+CAPACITOR-START 47-56UF/220TO 037251-34 1 2 103
+RELAY-MTR START TI#4CR-1-625 039725-27 1 2 103
+OVERLOAD-TI #2BM-20V9R-KK20-71 044464 1 2 103
+NUT-OVERLOAD RESET 045026 1 2 000
NUT-STUD-BLACK 2.563 LONG 058764 2 2 103
NUT-STUD-BLACK 3.250 LONG 058765 2 2 103
PAIL-MIX 10 QT. 013163 1 1 000

60
PAN-DRIP 11-5/8 LONG 027503 1 103
PAN A.-DRIP 5 1/2" LONG *C70 X56074 1 103
PAN-DRIP 12.5 059736 2 NNN
PAN-DRIP 19-1/2 LONG 035034 1 103
PAN-DRIP 7.875 059737 2 103
PANEL A.-FRONT-LOWER *C708* X58955 1 103 S/N K4115494 AND UP
PANEL A.-FRONT-UPPER *C708* X59423 1 103 S/N K4115494 AND UP
PANEL A.-FRONT-LOWER *C708* X56954 1 103 S/N K4087456 & PRIOR
PANEL A.-FRONT-UPPER *C708* X57017 1 103 S/N K4087456 & PRIOR
PANEL-SIDE-LEFT *C708* 056963 1 103
PANEL A-SIDE-RIGHT *C707* X57871 1 103 TOP AIR DISCHARGE USE X57869
PANEL-REAR *C706* 056077 1 103 5/24/2004 & UP
PANEL-REAR *C708* 056966 1 103 6/27/02 To 5/28/04
PANEL A.-FILTER-LOUVERED X59928 2 103
PANEL A.-FRONT *C712/C716* X63879 1 103 TOP UPPER S/N K6024393 & UP
PANEL A.-FRONT *C712-C717* X59836 1 103 NOSE CONE
PANEL A.-FRONT LOWER X59854 1 103

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
PANEL-CORNER-FRNT-R *C712/C716 063087 1 103
PANEL-CORNER-FRNT-L*C712/C716 063088 1 103
PANEL-REAR *C712/C716* 064258 1 103
PANEL-SIDE-LEFT *C712/C717* 059906 1 103
PANEL-SIDE-RIGHT *C712/C717* 059907 1 103

Models C708 & C716


PCB A.-INTERFACE *C708* ROHS X63929-SER 1 212 S/N K6076635 & UP - DEC PLATE
CHIP-SOFTWARE *C602* FP X40821 1 103
PCB A.-INTERFACE *C708* X57177-SER 1 S/N K6053040 & PRIOR - DEC PLATE
CHIP-SOFTWARE *C602* FP X40821 1 103
PCB A.-INTERFACE-HT-SS-C708 X58505-SER 1 212
PCB A.-PERSONALITY-HT-SS X46904-SER 1 212
PCB A.-HT INTERFACE BASE-C708 X58482-SER 1 212
CHIP-SOFTWARE MIX LEVEL X40799 1 103
PCB A.-CONTROL *C708* UVC3SM X59209-SER 1 212
CHIP-SOFTWARE C708 UVC3SM X40828 1 103
PCB A.-INTERFACE-HT-SS-UK ROHS X63966-SER 1 212 50HZ UNITS - INSTALLED AFTER 7/1/2006

61
PCB A.-ROHS-PERSON-HT-SS X63922-SER 1 212 50HZ UNITS - INSTALLED AFTER 7/1/2006
PCB A.-CONTROL-ROHS-INTF BASE X63928-SER 1 212 50HZ UNITS - INSTALLED AFTER 7/1/2006
PCB A.-CONTROL *C716* UVC3 SM X62292-SER 1 212
+CHIP-SOFTWARE C716 UVC3SM X40890 1 103
+CONTROL-UVC3 SURFACE MOUNT-P 062529 1 212 REPLACES 059189
PCB A.-INTERFACE X59435-SER 2 212 CONTROL
PCB A.-PERSONALITY-HT-SS X46904-SER 2 212
PCB A.-INTERFACE-HOT GAS-C602 X59485-SER 2 212
PCB A.-INTERFACE*C712-C717*ROH X63925-SER 1 212 50 Hz units - K6076635 & up - Plate A.-Dec
PCB A.-INTERFACE *C712-C717* X62101-SER 1 212 50 Hz units - K6053040 & prior Plate A.-Dec
+CHIP-SOFTWARE *C602* FP X40821 1 103
PIN-RETAINING-HOPPER COVER 043934 4 2 103
PLATE-DEC *C708* 056958 1 103
+GASKET-DEC PLATE *C708* 056991 1 000
+INSULATOR-PCB-INTERFACE 057798 1 000
PLATE-DEC *C716* SYRUP RAIL 062123 1 103
+INSULATOR-PCB-INTERFACE *C60 057168 1 000

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
PLUG-DRIP TRAY HOLE 029595 1 103

Parts List
PROBE A.-MIX X56912 1 103 MIX LOW
PROBE-MIX OUT *C708* 056908 1 103 MIX OUT
+O-RING-1-3/8 OD X .070W 017395 3 000
PROBE-THERMISTOR-BARREL-2% TOL 038061-BLK 1 HARNESS-WIRE-THERMISTOR PROBES
PROBE-THERMISTOR-HOPPER-2% TOL 039470-BLK 1 HARNESS-WIRE-THERMISTOR PROBES
PULLEY-2AK22 X .625-.6265 016403 1 2 103 208-230 60HZ 1PH & 3 PH
PULLEY-2AK27 X .625-.6265 011545 1 2 103 50HZ 1PH - 50HZ 3 PH -
PULLEY-2AK74-5/8 027822 1 2 103 208-230V 60HZ 1 PH GEAR
PUMP A.-MIX SIMPLIFIED S.S. X57029-14 1 2 103
ADAPTOR-MIX INLET*SOFT/SER*RED 054825 1 2 103
CAP-VALVE BODY SS 056874-14 1 2 103
+CLIP-RETAINER-MIX PUMP 044641 1 2 103
CYLINDER A.-PUMP-HOPPER-S.S. X57025 1 103
GASKET-SIMPLIFIED PUMP VALVE 053527 1 2 000
O-RING-2-1/8 OD X .139W-#225 020051 2 4 000

62
PIN A.-RETAINING X55450 1 2 103
+PIN-COTTER-HAIRPIN-1/8DIA 044731 1 2 103
PISTON 053526 1 2 103
RECEIVER A.-REFRIG.AC*C708/709 X59351 1 103
RELAY-3 POLE-20A-208/240 50/60 012725-33 1 2 103
RELAY-DPDT 100UA TO 7A 1/8HP 052111-03 1 2 103 BEATER INTERLOCK
RELAY-DPDT-24VAC-30A@277V 054703-03 2 103 HOT GAS SOLENOIDS
RELAY-MTR START TI#4CR-1-625 039725-27 1 2 103
SANITIZER KAY-5 125 PACKETS 041082 1 1 000
SHAFT A.-DRIVE-MIX PUMP-HOPPER X41947 1 2 103
O-RING-1-3/4 OD X .139W 008904 1 2 000
CRANK-DRIVE-HOPPER MIX PUMP 039235 1 2 103
SHAFT-DRIVE-MIX PUMP-HOPPER 041948 1 2 103
O-RING 1/2 ID X .139W 048632 2 4 000
SHAFT-BEATER *C706/C707* 056078 1 103
+SEAL-DRIVE SHAFT 032560 1 000
SHAFT-BEATER 032564 2 103

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
+SEAL-DRIVE SHAFT 032560 2 000
SHELF-TRAY-DRIP *C706* 056076 1 103
SHELL A.-INSULATED *C708/C709 X56969 1 512
+STUD-NOSE CONE *C602* 055987 4 103
SHELL A.-INSULATED *C716* X63818 1 512

Models C708 & C716


+STUD-NOSE CONE *C602* 055987 4 103
SHIELD-SPLASH *RD30* 049203 1 103
SHIELD-SPLASH-WIRE-19-3/4 L 033813 1 103
SHROUD A.-CONDENSER *C708/C709 X56922 1 103
SLEEVE A.-MIX PUMP *HT*MCD X44761 1 2 103
+NUT-PUMP SLEEVE *8751*HT* 036933 1 2 000
STARTER-1 PHASE-4.5 TO 7 A 041950-27K 1 2 103 208-230V 60HZ 1PH & 220-240V 50HZ 1PH
STARTER-3 PHASE-3 TO 5 AMP 041950-33J 1 2 103 208-230V 60HZ 3PH - 220/240V 60HZ 3PH
STARTER-3 PHASE-2.0 TO 3. 041950-33H 1 103 380-415V 50HZ 3N~
STRAINER-CONE MESH-1/4 ODF 062298 5 4 000
STRAINER-CONE MESH 1/2 ODF 062299 2

63
SWITCH A.-DRAW *C706* X56147 1 103
ARM A.-DRAW *C706* X56253 1 103
E-RING 3/16 .335 O.D. 049178 1 000
INSULATOR-SWITCH 1/64 ARMITE 029099 2 000
NUT-4-40 HEX -PLATED- 038623 2 000
PIN-PIVOT 015478 1 103
SCREW-4-40X1 RD HD STEEL-ZP 028890 2 000
SPRING-RETURN-LEFT-SELF CLOSE 041660 1 103
SPRING-RETURN-RIGHT-SELF CLOSE 041661 1 103
SWITCH-LEVER-SPDT-10A-125-250V 028889 2 103
SWITCH A.-DUAL LEVER X62400 1 103 s/n K5027279 & up - see Switch-Lever/Actuator
SWITCH-LEVER-SPDT-10A-125-25 028889 4 103
SCREW-4-40X1" TAPTITE PAN HD 045141 4 000
BRACKET-SWITCH*C712* 062394 2 103
ACTUATOR-TANDEM LEAF 062408 1 103
SWITCH A.-DRAW *SELF CLOSING* X59905 1 103 S/N K4115575 & PRIOR
ARM-SWITCH-DRAW-L 038649 1 103

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
ARM-SWITCH-DRAW-R 038650 1 103

Parts List
E-RING 1/4 032190 4 000
PIN-PIVOT-DRAW SWITCH 038484 1 103
ROD-SPRING RETAINER 038254 1 103
SCREW-4-40X1/2"TAPTITE PAN HD 042604 4 000
SPRING-EXTENSION.375X.045X1.00 038922 2 103
SPRING-RETURN-LEFT-TWIN TWIST 038923 1 103
SPRING-RETURN-RIGHT-TWIN TWIST 038924 1 103
SWITCH-LEVER-SPDT-11A-125-277V 039252 2 103
SWITCH-PRESSURE 440 PSI-SOLDER 048230 1 2 103 LINE A.-DISCHARGE
SWITCH-PRESS 220 CO/270 CI 064282 1 103
SWITCH-REED *DOOR INTERLOCK* 056249 1 1 103 K7072606 & PRIOR - BEATER INTERLOCK
SWITCH-REED*DOOR INTERLOCK*6 056771 1 103 K7085360 & UP - SEE INTERLOCK A.-DOOR
SWITCH-TOGGLE-DPDT*ON-NONE-ON 024295 1 103
TOOL-O-RING REMOVAL-FREEZER 048260-WHT 1 000
TOOL-SHAFT-DRIVE-PUMP-HOPPER 057167 1 1 000

64
TOOL-SHAFT-DRIVE-PUMP HOPR/LVB 047919 1 000
TRANS.-120/208/240V PRI 24VSEC 051660 1 103 SOLENOIDS
TRANS.-CONT.-32VA 120/200/240V 054834 1 103 INTERFACE BOARD
TRAY-DRIP *C706/C707*BLACK 056858 1 103
TRAY-DRIP-19-5/8 L X 4-7/8 033812 1 103
TRAY-DRIP *C716* 063877 1 103 HOLDS 033812 TRAY S/N K6024393 & UP
TRAY-PARTS-BARREL-3.4 QT TWIST 045755 1 103
TRAY-PARTS-BARREL-3.4 QT-17"HT 045756 1 000
TRAY-PARTS-PUMP-SIMPLIFIED SS 056525 1 2 000
TRIM-CORNER-REAR-LEFT *C708* 056964 1 103
TRIM-CORNER-REAR-RIGHT *C708* 056965 1 103
TRIM-CORNER-REAR-L 059896 1 103
TRIM-CORNER-REAR-R 059897 1 103
TUBE A.-FEED-HOPPER S.S. X56521 1 103 MIX PUMP
+RING-CHECK-FEED-TUBE 056524 1 000
+O-RING-11/16ODX.103W-RED 016132 2 000
TUBE A.-FEED-LEFT *C712/C717* X59808 1 103

Models C708 & C716


DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
+O-RING-11/16ODX.103W-RED 016132 2 000
+RING-CHECK-FEED-TUBE 056524 1 000
TUBE A.-FEED-RIGHT *C712/C717* X59809 1 103
+O-RING-11/16ODX.103W-RED 016132 016132 2 000
+RING-CHECK-FEED-TUBE 056524 1 000

Models C708 & C716


VALVE-ACCESS-1/4MFL X 3/8ODSDR 053565 2 4 103 LINE A.-DISCHARGE
VALVE-CRANKCASE PRESS REG 064347 1 S/N K7085360 & UP REPLACES 057008
VALVE-EPR 5/8FS 065371 1 S/N K7085360 & UP REPLACES 057009
+BOOT-INSULATING-EPR 062048 2
VALVE-EXP-AUTO-1/4S X1/4 FPT 046365 1 2 103 BARREL/HOT GAS BYPASS
+BOOT-VALVE-EXPANSION 050900 1 2 000 BARREL
VALVE-SOL 1/8ORF 1/4INX3/8OUT 053511-27 1 2 103
VALVE-SOLENOID 7/16 ORF 5/8ODF 048626-27 1 2 103
VALVE-SOLENOID 7/64ORF X 1/4S 043449-27 4 8 103 LINE A.-DRYER/VALVES
VALVE-THERMOSTATIC 057002 1 2 103 HOPPER
+BOOT-VALVE-EXPANSION 027137 1 000 HOPPER

65
VALVE-LIQUID INJ-HT GAS 057075-1 1 K7012344 & UP - LINE A.-DRYER/VALVES
VALVE-TREV 3/8X3/8 220 *161* 055378 1 2 103 K6112655 & PRIOR LINE A.-DRYER/VALVES
VALVE-TREV 1/4ODFX3/8 W/STRA 063951 2 LIQUID LINE
VIDEO-TRAIN C708/C709/C716/717 062069-V 1 1 000 USE 062069-DVD
VIDEO-TRVIDEO-TRAIN 062069-PAL 000 PAL=INTERNATIONAL FORMAT-MAY USE
C708/C709/C716/717 062069-DVD

WATER COOLED
BLOWER A. C712/C717 X62380-27G 1
BRACKET A.-MOUNTING CONDENSER X58931 1
BRACKET-VALVE-W/C *C708* / 058440 1
BRACKET-VALVE-W/C *C708* 058440 1 NNN
CONDENSER-WC-COAX 047540-1 1 103
CONDENSER-WC-COAX 047540 1 103
GUARD-BLOWER 022505 1 103
FAN-5 BLADE 7 " PUSH 30D 016289 1 103
HOSE-RUBBER 1/2"ID X 7/8"/ R50200 5 10 000

Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
MANIFOLD-1/2S THRU-1/4S OUT- 046688 1 103

Parts List
MOTOR A.-FAN *C708* WC X59307-27 1 NNN
MOTOR-FAN 9 WATT 1550RPM-CW 012768-27 1 103
TERMINAL-MAL.SP.INS.18-22.25 026962 1 000
BRACKET-FAN *453/750* 038641 1 103
SCREW-8-36X3/8 SLOT HEX WASH 046137 5 000
ADAPTOR-3/8MP X 1/2 BARB- 011021 2 103
OUTLET A.-TEE X25900 1 103
PLATE-CONDENSER W/C 062043 1
PLATE A.-MOUNTING-COUPLING X58935 1
PLATE A.-MOUNTING-COUPLING X58935 1 103
PLATE-CONDENSER W/C 062043 1 103
SWITCH-PRESSURE 350 PSI-SOLD 048231 1 2 103
TEE-3/8" PIPE WATER VALVE 032953 1 103
VALVE-WATER 3/8 REG/HEAD 046686 1 2 103

66
TOP AIR DISCHARGE
PANEL A.-SIDE-RIGHT *C708 X57869-SER 1 103

Models C708 & C716


Model C708
057010-27
Rev. 2/08
Model C708
057010-27
Inset
Rev. 2/08
Model C708
057010-33
Rev. 2/08
Model C708
057010-40
Rev. 2/08
Model C708
057010-58
Rev. 2/08
Model C716
059900-27
Rev. 2/08
Model C716
059900-27
Inset
Rev. 2/08
Model C716
059900-33
Rev. 2/08
Model C716
059900-40
Rev. 2/08
Model C716
059900-58
Rev. 2/08

You might also like