Taylor Aparat Za Sladoled
Taylor Aparat Za Sladoled
Taylor Aparat Za Sladoled
Heat Treatment
Soft Serve Freezer
Operating Instructions
059061--M
6/17/08
Complete this page for quick reference when service is required:
Taylor Distributor:
Address:
Phone:
Service:
Parts:
Date of Installation:
Model Number:
Serial Number:
Phase
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
The word Taylor and the Crown design
are registered trademarks in the United States 750 N. Blackhawk Blvd.
of America and certain other countries. Rockton, IL 61072
Table of Contents
Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Daily Closing Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Daily Opening Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Manual Brush Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Draining Product From The Freezing Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Rinsing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Hopper Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Brush Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Section 7 Important: Operator Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
During Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Troubleshooting Bacterial Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Regular Maintenance Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Winter Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Section 8 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Taylor Company
The word Taylor and the Crown design
a division of Carrier Commercial Refrigeration, Inc.
are registered trademarks in the United States 750 N. Blackhawk Blvd.
of America and certain other countries. Rockton, IL 61072
Installer Safety
081208
This will allow for adequate air flow across the FOLLOW YOUR LOCAL ELECTRICAL CODES!
condensers. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the Each freezer requires one power supply for each
compressors. data label. Check the data label on the freezer for
fuse, circuit ampacity and electrical specifications.
Refer to the wiring diagram provided inside of the
electrical box, for proper power connections.
080912
Beater Rotation
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
Beater rotation must be clockwise as viewed apply ice packs and contact a physician
looking into the freezing cylinder. immediately.
080912
Your freezers have been carefully engineered and The user is responsible for returning the product to
manufactured to give you dependable operation. the appropriate collection facility, as specified by
These units, when properly operated and cared for, your local code.
will produce a consistent quality product. Like all
mechanical products, they will require cleaning and For additional information regarding applicable local
maintenance. A minimum amount of care and laws, please contact the municipal facility and/or
attention is necessary if the operating procedures local distributor.
outlined in this manual are followed closely.
This Operator's Manual should be read before
operating or performing any maintenance on your Compressor Warranty Disclaimer
equipment.
The refrigeration compressors on this machine are
Your Taylor freezer will NOT eventually compensate
warranted for the term indicated on the warranty
for and correct any errors during the set-up or filling
card accompanying this machine. However, due to
operations. Thus, the initial assembly and priming
the Montreal Protocol and the U.S. Clean Air Act
procedures are of extreme importance. It is strongly
Amendments of 1990, many new refrigerants are
recommended that personnel responsible for the
being tested and developed, thus seeking their way
equipment's operation, both assembly and
into the service industry. Some of these new
disassembly, go through these procedures together
refrigerants are being advertised as drop-in
in order to be properly trained and to make sure that
replacements for numerous applications. It should
no confusion exists.
be noted that, in the event of ordinary service to this
In the event you should require technical assistance, machine's refrigeration system, only the refrigerant
please contact your local authorized Taylor specified on the affixed data label should be
Distributor. used. The unauthorized use of alternate refrigerants
will void your compressor warranty. It will be the
Note: Warranty is valid only if the parts are owner's responsibility to make this fact known to any
authorized Taylor parts, purchased from an technician he employs.
authorized Taylor Distributor, and the required
service work is provided by an authorized Taylor It should also be noted that Taylor does not warrant
service technician. Taylor reserves the right to deny the refrigerant used in its equipment. For example, if
warranty claims on equipment or parts if the refrigerant is lost during the course of ordinary
non-approved parts or refrigerant were installed in service to this machine, Taylor has no obligation to
the machine, system modifications were performed either supply or provide its replacement either at
beyond factory recommendations, or it is determined billable or unbillable terms. Taylor does have the
that the failure was caused by neglect or abuse. obligation to recommend a suitable replacement if
the original refrigerant is banned, obsoleted, or no
Note: Constant research results in steady longer available during the five year warranty of the
improvements; therefore, information in this compressor.
manual is subject to change without notice.
Taylor will continue to monitor the industry and test
new alternates as they are being developed. Should
a new alternate prove, through our testing, that it
If the crossed out wheeled bin symbol is would be accepted as a drop-in replacement, then
affixed to this product, it signifies that this product is the above disclaimer would become null and void.
compliant with the EU Directive as well as other To find out the current status of an alternate
similar legislation in effect after August 13, 2005. refrigerant as it relates to your compressor warranty,
Therefore, it must be collected separately after its call the local Taylor Distributor or the Taylor Factory.
use is completed, and cannot be disposed as Be prepared to provide the Model/Serial Number of
unsorted municipal waste. the unit in question.
080714
080912
This unit has many sharp edges that can C716: A minimum of 3” (76 mm) air space is
required on all sides. Install the deflector provided to
cause severe injuries.
prevent recirculation of warm air.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product Failure to follow these instructions may cause poor
and cause severe personal injury from blade freezer performance and damage to the machines.
contact.
S USE EXTREME CAUTION when removing For Indoor Use Only: This unit is designed to
the beater asssembly. The scraper blades operate indoors, under normal ambient
are very sharp. temperatures of 70_ - 75_F (21_ - 24_C). The
freezer has successfully performed in high ambient
S CAUTION-SHARP EDGES: Two people are
temperatures of 104_(40_C) at reduced capacities.
required to handle the cup/cone dispenser.
Protective gloves must be worn and the
mounting holes must NOT be used to lift or NOISE LEVEL: Airborne noise emission does not
hold the dispenser. Failure to follow this exceed 78 dB(A) when measured at a distance of
instruction can result in personal injury to 1.0 meter from the surface of the machine and at a
fingers or equipment damage. height of 1.6 meters from the floor.
080826
Figure 1
Figure 2
061228
Figure 3
Figure 4
080805
Figure 5
Figure 6
Figure 7
060629
Figure 8
C708 C716
Figure 9
ITEM DESCRIPTION
1 POWER SWITCH
2 LIQUID CRYSTAL DISPLAY
3 KEYPADS
4 MIX OUT INDICATOR
5 STANDBY INDICATOR
6 MIX LOW INDICATOR
7 SELECT KEY
8 SERVICE MENU KEY
9 BRUSH CLEAN COUNTER
10 ARROW KEY(S)
050628
Initializing
Language
+
Note: If there is a language initialization fault, the
machine will force a language selection prior to the
-
initializing sequence. The standard menu LED's
should light, as if it were in a menu. If a language
has been selected, the unit is powered down, the
machine should not ask for a language unless there
is another language initialization fault. English is the
Figure 10 factory default setting.
050628
Initializing
Config Data
SAFETY TIMEOUT
ANY KEY ABORTS
050628
DO NOT DRAW
UNIT CLEANED
050628
SYSTEM FAULT If the reason for the soft lock has been corrected,
FREEZER LOCKED selecting HEAT CYCLE initiates a Heat Cycle
SERVICE REQ'D immediately. Selecting BRUSH CLEAN when the
> BRUSH CLEAN previous message is displayed will hard lock the
machine and brush cleaning will be necessary.
080222
FREEZER LOCKED
A soft lock can also occur any time during operation
when the hopper or freezing cylinder temperature
rises above 59°F (15°C), the temperature rises and
remains above 45°F(7°C) for more than one hour, or
the temperature rises and remains above 41°F(5°C) To restore the message that identified the reason for
for more than four hours. the soft lock, turn the power switch OFF for five
seconds, and then return the power switch to the
If a PRODUCT OVER TEMPERATURE condition ON position. The original message with the reason
occurs during operation, the following screen will for the soft lock will be displayed.
appear.
050628
8 3 0 9
__
Figure 11
There is a two minute time-out in effect during the Manager Menu Options
Manager's Menu. While in the Manager's Menu, if no
activity occurs within a two minute period, the Touch the ARROW symbols to move up or down
display will exit to the Main Menu. There is one through the Menu. Select a Menu option by touching
exception to this time-out, and that is the Current the SEL symbol. Exit the Menu program by selecting
Conditions Display. EXIT FROM MENU or touch the CONE symbol.
The following menu options are listed in the
Note: The machine will continue operation in the
Manager's Menu.
mode it was in when the Menu was selected.
However, the control keys will not be lit and are
EXIT FROM MENU
non-functional when the Manager's Menu is
displayed. The control keys are functional in the RESET DRAW COUNTER
Manager's Menu when the CURRENT SET CLOCK
CONDITIONS screen is displayed. (See CURRENT
CONDITIONS on page 28.) AUTO HEAT TIME
060413
SYSTEM INFORMATION
CURRENT CONDITIONS
SET CLOCK
12:01 2/21/2004
Selecting “EXIT FROM MENU” will exit the Change
Manager's Menu and the return the control panel > Exit
symbols to normal operation.
SERVINGS COUNTER
0 SET CLOCK
> Next 12:01 2/21/2004
> Exit
080222
080222
Always comply with local guidelines on the number HPCO COMPRESSOR - Place the power switch in
of days allowed between brush clean cycles. the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart in AUTO.
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when HOPPER THERMISTOR BAD* - Place the power
there is Mix Low or Mix Out condition. The following switch in the OFF position. Replace the hopper
screen is displayed upon selecting this option. thermistor probe.
LOCKOUT HISTORY 1 BEATER OVLD H/C - The overload tripped for the
00/00/00 00:00 beater motor.
Reason
> Exit BRL THERM FAIL - The thermistor sensor for the
freezing cylinder failed.
The second line of the screen displays the date and HOPPER THERM FAIL - The thermistor sensor for
time a failure occurs. The third line indicates the the hopper failed.
reason for a failure, or will indicate if a successful
brush cleaning has occurred. Some failures occur
HPCO H/C - The high pressure switch opened
with multiple reasons. When this occurs, a page will
during the heat treatment cycle.
be generated for each reason.
Use the arrow symbols to advance forward or move
backward to view each screen. Listed below are the
variable messages that may appear.
Faults Occurring While in AUTO Mode
Faults Occurring Entering a Heat (L/R) HPR>41F (5C) AFTER 4 HR - The mix
Treatment Cycle temperature in the hopper was above 41°F (5°C)
more than four hours.
POWER SWITCH OFF - The power switch is OFF.
(L/R) BRL>41F (5C) AFTER 4 HR - The mix
AUTO OR STBY OFF - The control was not in the
temperature in the freezing cylinder was above 41°F
AUTO or STANDBY mode.
(5°C) more than four hours.
MIX OUT FAILURE - A Mix Out condition was
present. (L/R) HPR>41F (5C) AFTER PF - The mix
temperature in the hopper was above 41°F (5°C)
NO HEAT CYCLE TRIED - The Auto Heat Time
more than four hours following a power failure.
was set to attempt a heat cycle more than 24 hours
after the last successful heat cycle.
(L/R) BRL>41F (5C) AFTER PF - The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours following a power failure.
Faults Occurring While in Heat Mode
(L/R) HPR>45F (7C) AFTER 1 HR - The mix
HEAT MODE FAILURE - The maximum allowable temperature in the left or right hopper was above
heat mode time exceeded 90 minutes. 45_F (7_C) more than one hour.
COOL MODE FAILURE - The maximum allowable
(L/R) BRL>45F (7C) AFTER 1 HR - The mix
cool mode time exceeded 90 minutes.
temperature in the left or right barrel was above
TOTAL TIME FAILURE - The maximum allowable 45_F (7_C) more than one hour.
total heat treatment time exceeded 4 hours.
(L/R) HPR>59F (15C) - The mix temperature in the
BRUSH CLEAN TIMEOUT - The total days in
hopper exceeded 59°F (15°C).
operation exceeded the brush clean cycle setting.
POWER SWITCH OFF - The power switch was (L/R) BRL>59F (15C) - The mix temperature in the
turned OFF during the heat cycle. hopper exceeded 59°F (15°C).
050628
H: 38.0 B:23.7 R
HEAT OVER COOL PEAK
The HEAT CYCLE DATA screen contains a record 1:09 0:52 h 1:11 161.2
of up to 366 heat treatment cycles. The most recent 0:66 1:00 b 0:11 169.9
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the month and day of the heat cycle, The HEAT time indicates the amount of time taken
the start time and end time, and the fault description. in each zone to reach 150.9°F (66.1°C). Each zone
The bottom line displays the record number and must remain above 150°F (65.6°C) for a minimum of
indicates if a power failure occurred during the heat 35 minutes.
cycle (POWER FAILURE IN HC).
Touch the UP arrow symbol to advance to the next
page or the DOWN arrow symbol to view the
HEAT TREAT CYCLE previous page. A Heat Cycle Failure message will
01/01 02:00 05:14
NO FAULT FOUND
display on the first screen if a failure occurred.
1
Listed below are variable failure code messages
which could appear on line 2.
Touch the UP arrow symbol to advance forward
through the data pages. Touch the DOWN arrow HT HEAT TIME FAILURE
symbol to reverse the page direction. Mix temperature did not rise above 151_F
(66.1_C) in less than 90 minutes.
Hopper and barrel temperature records for each side CL COOL MODE FAILURE
of the freezer are displayed in the second and third Mix temperature in the hopper and freezing
screens. The second screen shows the left side (L) cylinder did not fall below 41_F (5_C) in less
side of the freezer. than 90 minutes.
The third screen shows the right side (R) of the TT TOTAL TIME FAILURE
freezer. The heat treatment cycle must be completed
in no more than 4 hours.
The top line of these screens shows the hopper (H)
ML MIX LOW FAILURE
and barrel (B) temperatures recorded at the end of
The Heat Phase or Cool Phase time was
the Heat Treat Cycle and indicates the side (L or R)
exceeded and a mix low condition was pres-
of the freezer. ent.
The remaining lines indicate the following: MO MIX OUT FAILURE
A mix out condition was detected at the start
HEAT = Total time for the hopper (h) and barrel (b)
or during the heat cycle.
to reach 150.9°F (66.1°C).
BO BEATER OLVD IN HC
OVER = Total time the hopper (h) and barrel (b) A beater overload occurred during the heat
temperature was above 150°F (65.6°C). cycle.
COOL = Total time the hopper (h) and barrel (b) HO HPCO IN HEAT CYCLE
temperature was above 41°F (5°C) during the COOL A high pressure cut-out condition occurred
phase. during the heat cycle.
050628
Language
V2.00 English 621
> Next
081111
Step 5
Note: When lubricating parts, use an approved food Insert the beater drive shaft through the rear shell
grade lubricant (example: Taylor Lube). bearing in the freezing cylinder and engage the hex
end firmly into the drive coupling. (See Figure 16.)
Step 1
Before installing the beater drive shaft, lubricate the
groove on the beater drive shaft.
Step 2
Slide the beater drive shaft boot seal over the small
end of the beater drive shaft and engage into the
groove on the shaft. Figure 16
Figure 19
Step 9
Slide the beater assembly the rest of the way into
the freezing cylinder.
Step 7
Holding the rear blade on the beater, slide it into the
freezing cylinder halfway. Install the front scraper
blade over the front holding pin. (See Figure 18.)
11249
Figure 20
Figure 23
Step 4
Insert the draw valve from the top, with the draw
handle slot facing forward. (See Figure 24.)
Figure 21
Step 2
Slide the three o-rings into the grooves on the draw
valve and lubricate. (See Figure 22.)
10423
Figure 22 Figure 24
Figure 25
Step 6
Slide the fork of the draw handle into the slot of the
draw valve. Secure with pivot pin. (See Figure 26.) Figure 27
Step 8
Install the front drip tray and splash shield under the
door spout. (See Figure 32.)
Figure 26
Note: The C708 features an adjustable draw handle
to provide portion control, giving a better consistent
quality to your product and controlling costs. Figure 28
Figure 30
Step 7
Position each draw handle with the adjustment
screw facing down. Slide the fork of each draw
handle into the slot of each draw valve, starting from
the right.
Figure 29 Step 8
Slide the pivot pin through the draw handles as the
Step 4 handles are inserted into the draw valves
Slide the three o-rings into the grooves of each
standard draw valve. Slide the H-ring and o-ring into
the grooves of the center draw valve. Lubricate the Note: This freezer features adjustable draw handles
H-ring and o-rings. to provide portion control, giving a better consistent
quality to your product and controlling costs. The
Step 5 draw handles should be adjusted to provide a flow
Lubricate the inside of the freezer door spouts, top rate of 5 to 7-1/2 oz. (142 g. to 213 g.) of product by
and bottom. weight per 10 seconds.
Figure 31
Figure 33
Step 11
Install the front drip tray and splash shield under the Step 3
door spouts. (See Figure 32.) Apply a thin layer of lubricant to the inside of the
pump cylinder at the retaining pin hole end. (See
Figure 34.)
15130
LU BE
Figure 32 Figure 34
Insert the piston into the retaining pin hole end of the
pump cylinder. (See Figure 35.)
15123
Figure 37
Step 7
Insert the valve body cap into the hole in the mix
inlet adapter. (See Figure 38.)
15111
Figure 35
Step 5
Assemble the valve cap. Slide the o-ring into the
groove of the valve cap. DO NOT lubricate the
o-ring. (See Figure 36.)
15109
Figure 38
Step 8
Insert the mix inlet assembly into the pump cylinder.
(See Figure 39.)
15112
Figure 36
Figure 39
Step 6
Slide the pump valve gasket into the holes on the The adapter must be positioned into the notch
cap. DO NOT lubricate the gasket. (See Figure 37.) located at the end of the pump cylinder.
Figure 40
Figure 42
Note: The head of the retaining pin should located
at the top of the pump when installed. Step 12
Lay the pump assembly, pump clip, cotter pin and
Step 10 agitator in the bottom of the mix hopper for
Assemble the feed tube assembly. Slide the check sanitizing. (See Figure 43.)
ring into the groove of the feed tube.
(See Figure 41.)
12166
15133
Figure 41 Figure 43
Step 2
Pour the sanitizing solution over all the parts in the
bottom of the mix hopper and allow it to flow into the
freezing cylinder. (See Figure 46.)
Figure 44
Step 14
Install the hex end of the drive shaft into the drive
hub at the rear wall of the mix hopper.
(See Figure 45.)
Figure 46
Figure 45 Step 3
Note: For ease in installing the pump, position the While the solution is flowing into the freezing
ball crank of the drive shaft in the 3 o'clock position. cylinder, take particular care to brush-clean the mix
level sensing probe on the bottom of the hopper, the
Repeat these steps for the other side of the mix hopper, the mix inlet hole, the air/mix pump, the
Model C716. pump clip, the mix feed tube, and the locking clip.
080617
Step 11
With a pail beneath the door spout(s), open the draw
valve and touch the PUMP symbol . Open and
close the draw valve 6 times.
Figure 48
Step 6
Prepare another pail of approved 100 PPM sanitiz-
ing solution (examples: 2-1/2 gal. [9.5 liters] of
Kay-5R or 2 gal. [7.6 liters] of Stera-SheenR).
USE WARM WATER AND FOLLOW THE Figure 49
MANUFACTURER'S SPECIFICATIONS.
Step 7 Note: Be sure your hands are clean and
Pour the sanitizing solution into the mix hopper. sanitized before going on in these instructions.
080617
Step 1
Place an empty mix pail beneath the door spout(s).
Pour 2-1/2 gallons (9.5 liters) of FRESH mix into the
mix hopper and allow it to flow into the freezing
cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Figure 52
Step 4
Select the AUTO symbol .
Step 5
Fill the hopper with fresh mix and place the mix
Figure 51
hopper cover in position.
Repeat these steps for the other side of the Repeat these steps for the other side of the
Model C716. Model C716.
080222
080222
Figure 56
Step 4
Remove the locking clip, mix feed tube, pump clip
and the assembled air/mix pump.
Figure 59
Step 3
Drain all the rinse water from the door spout. Close
the draw valve and touch the WASH symbol,
Rinsing cancelling the WASH mode.
Step 4
Repeat this procedure using clean, warm water, until
Step 1 the water being discharged is clear.
Pour two gallons (7.6 liters) of cool, clean water into
the mix hopper. With the white hopper brush, scrub Repeat these steps for the other side of the
the mix hopper, mix level sensing probe and the Model C716.
outside of the agitator drive shaft housing. Using the
double ended brush, brush clean the mix inlet hole.
(See Figure 58.) Hopper Cleaning
Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 2
Pour the solution into the hopper and allow it to flow
into the freezing cylinder.
Step 3
Using the white hopper brush, clean the mix hopper,
mix level sensing probes and the outside of the
agitator drive shaft housing. Using the double ended
brush, clean the mix inlet hole. (Note: Do not brush
Figure 58
clean the mix inlet hole while the machine is in the
WASH mode.)
Note: Do not brush clean the mix inlet hole while
the machine is in the WASH mode. Step 4
Touch the WASH symbol . This will cause the
Step 2 cleaning solution in the freezing cylinder to come in
With a mix pail beneath the door spout,(s) open the contact with all areas of the freezing cylinder.
draw valve and touch the WASH symbol . Step 5
(See Figure 59.) Place an empty pail beneath the door spout(s).
080617
Disassembly
Figure 60
Note: Failure to remove the parts specified below
for brush cleaning and lubrication will result in Step 7
damage to the machine. These parts must be Remove the two small o-rings and one large o-ring
removed every 14 days or the machine will lock out from the pump drive shaft.
and will not operate.
Figure 62
080617
During Cleaning and Sanitizing j 7. Discard remaining mix from the freezer during
“Cleaning Procedures”.
Troubleshooting Bacterial Count j 3. Using a screwdriver and cloth towel, keep the
rear shell bearing and the female hex drive
socket clean and free of lubricant and mix
j 1. Thoroughly clean and sanitize the machine
deposits.
regularly, including complete disassembly and
brush cleaning.
j 4. Dispose of o-rings and seals if they are worn,
j 2. Use all brushes supplied for thorough torn, or fit too loosely, and replace with new
cleaning. The brushes are specially designed ones.
to reach all mix passageways.
j 3. Use the white bristle brush to clean the mix j 5. Follow all lubricating procedures as outlined in
inlet hole which extends from the mix hopper “Assembly”.
down to the rear of the freezing cylinder.
j 6. If your machine is air cooled, check the
j 4. Use the black bristle brush to thoroughly condensers for accumulation of dirt and lint.
clean the rear shell bearing located at the rear Dirty condensers will reduce the efficiency
of the freezing cylinder and the drive hub and capacity of the machine. Condensers
opening in the rear wall of the mix hopper. Be should be cleaned monthly with a soft brush.
sure there is a generous amount of cleaning Never use screwdrivers or other metal probes
solution on the brush. to clean between the fins.
Note: For machines equipped with an air
j 5. Properly prepare the cleaning and sanitizing filter, it will be necessary to vacuum clean the
solutions. Read and follow the label directions filters on a monthly schedule.
carefully. Too strong of a solution may
damage the parts and too weak of a solution
will not do an adequate job of cleaning or
sanitizing.
Caution: Always disconnect
j 6. The temperature of the mix in the mix hopper electrical power prior to cleaning the
and walk-in cooler should be below 40_F condenser. Failure to follow this instruction
(4.4_C). may result in electrocution.
050808
080222
3. No control panel functions a. Machine is unplugged. a. Plug into wall receptacle. ---
with power switch ON.
b. Circuit breaker OFF or b. Turn the breaker ON or ---
blown fuse. replace the fuse.
5. No product is being a. Low on mix. The MIX a. Add mix to the hopper. 39
dispensed. OUT light is on. Return to AUTO mode.
h. Feed tube or check ring h. Make sure feed tube and 36, 39
not properly installed. rubber check ring are
properly installed.
9. The mix in the hopper is a. The hopper temperature is a. Call an authorized service ---
too cold. out of adjustment. technician.
10. Mix Low and Mix Out a. Milkstone build-up in the a. Clean hoppers thoroughly. 45
probes are not hopper.
functioning.
11. Product is collecting on a. The top o-ring on draw a. Lubricate properly or 33
top of the freezer door. valve is improperly replace the o-ring.
lubricated or worn.
12. Excessive mix leakage a. Bottom o-ring on draw a. Lubricate properly or 33
from the bottom of door valve is improperly replace the o-ring.
spout. lubricated or worn.
15. The freezing cylinder a. Missing or worn front a. Install or replace the front 30, 33
walls are scored. bearing and beater shoes. bearing and beater shoes.
16. The product makes a a. Draw rate is set too fast. a. Adjust draw rate of 5 to 7 17
popping sound when 1/2 oz. (142 g. to 213 g.)
drawn. of product by weight in 10
seconds.
b. Pump assembled b. Assemble and lubricate 34
incorrectly. according to instructions
in this manual.
c. Freezing cylinder not c. Drain the freezing cylinder 39
primed correctly. and reprime the machine.
Scraper Blade X
Drive Shaft Seal X
Freezer Door Gasket X
Front Bearing X
Front Beater Shoes X
Draw Valve O-Ring X
Mix Feed Tube O-Ring X
Pump O-Ring X
Pump Valve Gasket X
Mix Feed Tube Check Ring X
Pump Drive Shaft O-Ring X
White Bristle Brush, 3” x 7” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 3” x 1/2” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 1-1/2” x 3” Inspect & Replace Minimum
if Necessary
White Bristle Brush, 1” x 2” Inspect & Replace Minimum
if Necessary
53
BELT-AX40 023875 2 000 220-240V 50HZ 1PH
BELT-AX32 032769 4 000
BELT-AX33 024396 4 000 380-415V 50HZ 3N~ (4WIRE)
BLADE A.-AGITATOR *C708* X56591 1 2 103
BLOCK-TERMINAL 2P .25 SPADE 051644 1 103
BLOCK-TERMINAL 2P .2 SCREWTYPE 040321-002 1 2 103
BLOCK-TERMINAL 2P-L1,N 039421 1 103 220-240V 50HZ 1PH
BLOCK-TERMINAL 2P-L1,L2 039422 1 2 103 208-230V 60HZ 1PH
BLOCK-TERMINAL 2P L1,N 039421 1 103 220-240V 50HZ 1PH
BLOCK-TERMINAL 3P-L1,L2,L3 039423 1 2 103 208-230V 60HZ 3PH
BLOCK-TERMINAL 4P L1,L2,L3,N 039424 1 103 380-415V 50HZ
BLOCK-TERMINAL 3P 20A, 300V 051331 1 103 208-230V 60HZ 1PH / 220-240V 50HZ 1PH
BLOCK-TERMINAL 7P GREEN 024156 1 103 380-415V 50HZ / 220-240V 50HZ 1PH
BLOCK-TERMINAL 2P .25 SPADE 051644 1 103 208-230V 50&60HZ 1PH&3PH/380-415V 50HZ
BLOWER-HIGH OUTPUT-HTGS 059750-27 1 103
BOOT-VALVE-EXPANSION 050900 1 2 000 BARREL
BOOT-VALVE-EXPANSION 027137 1 000 HOPPER TXV
Parts List
Parts List
Parts List
BRUSH-REAR BRG 1"D X 2"LG X 013071 1 1 000
BRUSH-DBL END-PUMP & FEED TUBE 013072 1 1 000
BRUSH-DRAW VALVE 1"OD X 2"X17" 013073 1 1 000
BRUSH-DRAW VALVE 1-1/2"OD X 14" 014753 1 1 000
BRUSH-MIX PUMP BODY-3" X 7" WH 023316 1 1 000
BRUSH-1/2" DIA 033059 1 1 000
BRUSH-END-DOOR-SPOUT-SS-HT 039719 1 1 000
BRUSH-SET LVB 050103 1 1 000
BRUSH-PUMP SPOUT *MC13* 054068 1 1 000
BRUSH-SET LVB 050103 1 1 000
CABLE-RIBBON-14C-14"L SIP/SIP 040040-015 1 103 PCB TOUCH PAD DISPLAY
CABLE-RIBBON-20C-14"L-DIL/DIL 040040-040 1 2 103 J2C TO J12IF
CABLE-RIBBON-20C-17"L-DIL/DILR 040040-013 1 103
CABLE-RIBBON-20C-18"L-DIL/DILR 040040-042 1 103 J7C TO J9IF
CABLE-RIBBON-50C-10"L-DIL/DIL 040040-058 1 103
54
CABLE-RIBBON-50C-20"L-DIL/DIL 040040-011 1 103 J10C TO J2IF
CABLE-RIBBON-50C-25"L.DIL/DIL 040040-025 1 103
CABLE-USB 056785 1 1 103 PCB TOUCH PAD DISPLAY
CAP-DESIGN 1.010"ID-6 POINT 014218 3 000
CAP-VALVE BODY SS 056874-12 1 103
CAP-VALVE BODY SS 056874-16 1 103
CAPACITOR-MOTOR-AGITATOR 057525 1 2 103
CAPACITOR-RUN 440VAC 50/60HZ 059789 1 1 103
CAPACITOR-START 47-56UF/220TO 037251-34 1 2 103
CAPACITOR-RUN 40MF/440V 036049 1 2 103 220-240V 50HZ 1PH ---716-40
CAPACITOR-START 216-259UF/33 048908 2 103 220-240V 50HZ 1PH ---716-40
CASTER-4" SWV 3/4-10 STM 044106 4 103
CD-OPS TRAINING VIDEO *C708* 062069-CD 1 1 000
COMPRESSOR L64A113BBCA 048259-27E 1 2 512 S/N K7112082 & UP - 208-230V 60HZ 1PH -
BRISTOL
+CAPACITOR-RUN 25UF/440V 037431 1 2 103
+CAPACITOR-START 189-227UF/33 033044-1 1 2 103
55
+CAPACITOR-RUN 40MF/440V 036049 1 103 "
+CAPACITOR-START 216-259UF/330V 048908 1 103 "
+RELAY-START-COMPRESSOR 051957-40 1 103 "
COMPRESSOR CS20K6E-TFD-238 057011-58 1 2 512 380-415V 50HZ 3N~ (4WIRE)
CONDENSER-AC 12LX18HX3.12T-5RW 055813-1 1 103 LEFT
CONDENSER-AC 12LX18HX3.12T-5RW 055813-2 1 103 RIGHT
CONDENSER-AC 16X16 3ROW 14FPI 056944 1 103
COUPLING-DRIVE 3/4 HEX X 1-7/8 012721 1 2 103
COUPLING-3/8FS X 1/4FS 031791 2 2 103
COUPLING-3/8FS X 5/16FS 054654 1 2 103 LINE A. DISCHARGE
COVER-HOPPER *BLACK* SEE KIT A.COVER-HOPPER
DECAL-INST-CLN-DAY-HT-SS 045273 1 1 000
DECAL-INST-CLN-HT-SS 045276 1 1 000
DECAL-TROUBLESHOOT 038374 1 1 000
DEFLECTOR-BLOWER-EXHAUST 059929 1 103
DIAGRAM-WIRING *C708/C709* 057010-27 1 000 208-230V 60HZ 1PH
DIAGRAM-WIRING *C708/C709* 057010-33 1 000 208-230V 60HZ 3PH
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
DIAGRAM-WIRING *C708/C709 057010-35 1 000 220-240V 50HZ 3PH
Parts List
DIAGRAM-WIRING *C708/C709* 057010-40 1 000 220-240V 50HZ 1PH
DIAGRAM-WIRING *C708/C709 057010-58 1 000 380-415V 50HZ 3N~
DIAGRAM-WIRING *C716* 059900-27 1 000 208-230V 60HZ 1PH
DIAGRAM-WIRING *C716* 059900-33 1 000 208-230V 60HZ 3PH - 3 WIRE
DIAGRAM-WIRING *C716* 059900-40 1 000 220-240V 50HZ 1PH
DIAGRAM-WIRING *C716* 059900-58 1 000 380-415V 50HZ 3N~ (4WIRE)
DOOR A.-W/BAFFLE X57332-SER 1 103
+GASKET-DOOR HT 4"-DOUBLE 048926 1 000
+HANDLE A.-DRAW-WELDED *C708* X56742 1 103
+O-RING-1/4 OD X .070W 50 DURO 015872 1 103
+O-RING-7/8 OD X .103W 014402 3 000
+PIN-HANDLE-SS *C602* 055819 1 103
+SCREW-ADJUSTMENT-5/16-24 *602* 056332 1 103
+VALVE A.-DRAW *C602* X55820 1 000
DOOR A.-3SPT*HT*LG BAF*W/O PRG X59923-SER 1 103
56
+BEARING-FRONT-SHOE 050348 2 000
+DECAL-DOOR-3 SPOUT-TWIN TWIST 062239 1 000
+GASKET-DOOR-4"-DART 048926-1 2 000
+HANDLE A.-DRAW-WELDED *C602* X56421-1 3 103
+O-RING-1/4 OD X .070W 50 DURO 015872 3 000
+O-RING-7/8 OD X .103W 014402 8 000
+PIN-HANDLE-TWIN *C712/C717* 059894 1 103
+SCREW-ADJUSTMENT-5/16-24 *602* 056332 3 103
+SEAL-DRAW VALVE 034698 1 000
+VALVE A.-DRAW-CENTER *C716/717 X59890 1 103
+VALVE A.-DRAW-L & R *C716/717 X59888 2 103
DRYER-FILTER-HP62-3/8 X 1/4S 048901 1 000
DRYER-FILTER 3/8 X 3/8SOL HP 049154 2 000
DVD-OPS TRAIN VID *C708/C716 062069-DVD 1 1 000
EYELET-RESET BUTTON 013739 2 6 103
FASTENER-DOOR LATCH 030787 2 2 000
FASTENER-DOOR STRIKE 030788 2 2 000
57
HARNESS-WIRE-COMPRESSOR 062056-33G 2 103 S/N K7112086 & UP -208-230V 60HZ 3
HARNESS-WIRE-COMP. RIGHT*863 056103 1 103 208-230V 60HZ 3
HARNESS-WIRE-COMP. RIGHT*863 056103-G 1 103 380-415V 50HZ 3
HARNESS-WIRE-MAIN POWER *C708* 058285-27G 1 103 208-230V 60HZ 1
HARNESS-WIRE-MAIN POWER *C708* 058285-33G 1 103 208-230V 60HZ 3
HARNESS-WIRE-MAIN POWER *C708* 058285-40 1 103 220-240V 50HZ 1
HARNESS-WIRE-MAIN POWER *C708* 058285-58 1 103 380-415V 50HZ 3
HARNESS-WIRE-SOL VLV/FAN MTR 057726 1 103 208-230V 60HZ 1PH / 208-230V 60HZ 3
HARNESS-WIRE-SOL VLV/FAN MTR 057726-G 1 103 220-240V 50HZ 1 PH / 380-415V 50HZ 3
HARNESS-WIRE-THERMISTOR-PROBE 057728 1 103 208-230v 60 1&3, 220-240v 50 1, 380-415 50 3
HOUSING A.-AGITATOR *C708* X56586-03 1 2 103
BODY-AGITATOR HOUSING *C708* 056588 1 2 103
CAP-AGITATOR HOUSING *C708* 056589 1 2 103
NUT-AGITATOR BELT HOUSING *H 043574 1 2 103
MAGNET A.-AGITATOR*C708* X57341 1 2 103
MAGNET A.-AGITATOR-INNER X41733 1 2 103
SCREW-8-32X3/16 ALLEN SET 006812 1 2 000
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
BUSHING-AGITATOR MAGNET 057342 1 2 NNN
Parts List
MOTOR-AGITATOR-24VAC 50/60 HZ 050535-03 1 2 103
O-RING-1-3/8 OD X .070W 017395 1 2 000
PLATE-HOLDING-AGITATOR *C708* 056587 1 2 103
SCREW-8-32X3/16 ALLEN SET 006812 1 2 000
SCREW-4-40X1/4 SOC SS 600165 2 4 000
INTERLOCK A.-DOOR X65658 1 1 103 S/N K7085360 & UP - REPLACES 056249
FITTING DOOR INTERLOCK 065471 1 1 103
SPRING-INTERLOCK DOOR 065409 1 1 000
SWITCH-REED*DOOR INTERLOCK*6 056771 1 1 103
JACK A.-FLAVORBURST *C706* X56353 1 2 103
KIT A.-COVER-HOPPER*SINGLE*BLK X65368 1 000
COVER-HOPPER *BLACK* 053809-1 1 103
LABEL-CAUTION-AGITATOR 045191 1 000
+PIN-RETAINING-HOPPER COVER 043934 4 103
KIT A.-COVER-HOPPER*DUAL*BLK X65178 1 000
58
COVER-HOPPER *BLACK* 053809-1 2 103
LABEL-CAUTION-AGITATOR 045191 2 000
+PIN-RETAINING-HOPPER COVER 043934 2 103
KIT A.-TUNE UP *C708* X63146 1 000
KIT A.-PUMP-SIMPLIFIED SS/SH X56200-10 1 000
O-RING-1-3/4 OD X .139W 008904 1 000 DRIVE CRANK
O-RING-11/16ODX.103W-RED 016132 2 000 PUMP FEED TUBE
O-RING-2-1/8 OD X .139W-#225 020051 2 000 VALVE CAP
O-RING 1/2 ID X .139W 048632 2 000 PUMP DRIVE SHAFT
GASKET-SIMPLIFIED PUMP VALVE 053527 1 000
RING-CHECK-FEED-TUBE 056524 1 000 FEED TUBE
KIT A.-DOOR/BARREL SS C602 X56200-14 1 000
O-RING-7/8 OD X .103W 014402 3 000 DRAW VALVE
SEAL-DRIVE SHAFT 032560 1 000 DRIVE SHAFT
GASKET-DOOR HT 4"-DOUBLE 048926 1 000
SHOE-FRONT HELIX *REAR* 050346 1 000 BEATER
SHOE-FRONT HELIX *FRONT* 050347 1 000 BEATER
59
GASKET-DOOR-4"-DART 048926-1 2 000
SHOE-FRONT HELIX *REAR* 050346 2 000
SHOE-FRONT HELIX *FRONT* 050347 2 000
BEARING-FRONT-SHOE 050348 2 000
TOOL-O-RING REMOVAL-FREEZER 048260-WHT 1 000
LABEL-CAUTION-GRD-PERM-ENG/SP 032164 1 1 000
LABEL-DOOR-MOVE PART 032749 1 1 000
LABEL-RESET-MIX PMP 044452 1 1 000
LABEL-SW-POWER-OFF/ON-SYMBOLS 052632 1 1 000
LABEL-WARN-COVER 051433 4 7 000
LIP-DRIP-NOSE CONE 036435 1 000
LIP-DRIP-NOSE CONE-TWIN 036434 1 000
LUBRICANT-TAYLOR HI PERF-4 OZ 048232 1 1 000
MAN-OPER C708/C716 059061-M 1 1 000
MANIFOLD-1/2S THRU-1/4S OUT- 046688 1 2 103 LINE A.-DISCHARGE
MOTOR-1.5 HP CAPS@8&10 O'CLOCK 056865-27 1 212 208-230V 60HZ 1PH
MOTOR-1.5 HP CAPS@8&10 O'CLOCK 056865-34 1 212 220-240V 50HZ 1PH
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
MOTOR-1.5 HP 021522-27 1 212 208-230V 60HZ 1PH
Parts List
MOTOR-1.5 HP 021522-33 1 2 212 208-230V 60HZ 3PH - 3 WIRE
MOTOR-1.5 HP CAPS@10&2 O'CLOCK 021522-34 2 212 220-240V 50HZ 1PH ---716-40
MOTOR-1.5 HP 021522-35 1 212 220-240V 50HZ 3PH & 380-415V 50HZ 3N~
MOTOR A.-AGITATOR SEE - HOUSING A.-AGITATOR
MOTOR-FAN W/4 BLADE 185W 500303-27 1 103
+CAPACITOR-RUN 4.0UF/400V 500311 1 103
+GUARD-FAN 500304 1 103
MOTOR-REDUCER 32 RPM-HPR PUMPM 036955-34 1 2 212
+CAPACITOR-START 47-56UF/220TO 037251-34 1 2 103
+RELAY-MTR START TI#4CR-1-625 039725-27 1 2 103
+OVERLOAD-TI #2BM-20V9R-KK20-71 044464 1 2 103
+NUT-OVERLOAD RESET 045026 1 2 000
NUT-STUD-BLACK 2.563 LONG 058764 2 2 103
NUT-STUD-BLACK 3.250 LONG 058765 2 2 103
PAIL-MIX 10 QT. 013163 1 1 000
60
PAN-DRIP 11-5/8 LONG 027503 1 103
PAN A.-DRIP 5 1/2" LONG *C70 X56074 1 103
PAN-DRIP 12.5 059736 2 NNN
PAN-DRIP 19-1/2 LONG 035034 1 103
PAN-DRIP 7.875 059737 2 103
PANEL A.-FRONT-LOWER *C708* X58955 1 103 S/N K4115494 AND UP
PANEL A.-FRONT-UPPER *C708* X59423 1 103 S/N K4115494 AND UP
PANEL A.-FRONT-LOWER *C708* X56954 1 103 S/N K4087456 & PRIOR
PANEL A.-FRONT-UPPER *C708* X57017 1 103 S/N K4087456 & PRIOR
PANEL-SIDE-LEFT *C708* 056963 1 103
PANEL A-SIDE-RIGHT *C707* X57871 1 103 TOP AIR DISCHARGE USE X57869
PANEL-REAR *C706* 056077 1 103 5/24/2004 & UP
PANEL-REAR *C708* 056966 1 103 6/27/02 To 5/28/04
PANEL A.-FILTER-LOUVERED X59928 2 103
PANEL A.-FRONT *C712/C716* X63879 1 103 TOP UPPER S/N K6024393 & UP
PANEL A.-FRONT *C712-C717* X59836 1 103 NOSE CONE
PANEL A.-FRONT LOWER X59854 1 103
61
PCB A.-ROHS-PERSON-HT-SS X63922-SER 1 212 50HZ UNITS - INSTALLED AFTER 7/1/2006
PCB A.-CONTROL-ROHS-INTF BASE X63928-SER 1 212 50HZ UNITS - INSTALLED AFTER 7/1/2006
PCB A.-CONTROL *C716* UVC3 SM X62292-SER 1 212
+CHIP-SOFTWARE C716 UVC3SM X40890 1 103
+CONTROL-UVC3 SURFACE MOUNT-P 062529 1 212 REPLACES 059189
PCB A.-INTERFACE X59435-SER 2 212 CONTROL
PCB A.-PERSONALITY-HT-SS X46904-SER 2 212
PCB A.-INTERFACE-HOT GAS-C602 X59485-SER 2 212
PCB A.-INTERFACE*C712-C717*ROH X63925-SER 1 212 50 Hz units - K6076635 & up - Plate A.-Dec
PCB A.-INTERFACE *C712-C717* X62101-SER 1 212 50 Hz units - K6053040 & prior Plate A.-Dec
+CHIP-SOFTWARE *C602* FP X40821 1 103
PIN-RETAINING-HOPPER COVER 043934 4 2 103
PLATE-DEC *C708* 056958 1 103
+GASKET-DEC PLATE *C708* 056991 1 000
+INSULATOR-PCB-INTERFACE 057798 1 000
PLATE-DEC *C716* SYRUP RAIL 062123 1 103
+INSULATOR-PCB-INTERFACE *C60 057168 1 000
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
PLUG-DRIP TRAY HOLE 029595 1 103
Parts List
PROBE A.-MIX X56912 1 103 MIX LOW
PROBE-MIX OUT *C708* 056908 1 103 MIX OUT
+O-RING-1-3/8 OD X .070W 017395 3 000
PROBE-THERMISTOR-BARREL-2% TOL 038061-BLK 1 HARNESS-WIRE-THERMISTOR PROBES
PROBE-THERMISTOR-HOPPER-2% TOL 039470-BLK 1 HARNESS-WIRE-THERMISTOR PROBES
PULLEY-2AK22 X .625-.6265 016403 1 2 103 208-230 60HZ 1PH & 3 PH
PULLEY-2AK27 X .625-.6265 011545 1 2 103 50HZ 1PH - 50HZ 3 PH -
PULLEY-2AK74-5/8 027822 1 2 103 208-230V 60HZ 1 PH GEAR
PUMP A.-MIX SIMPLIFIED S.S. X57029-14 1 2 103
ADAPTOR-MIX INLET*SOFT/SER*RED 054825 1 2 103
CAP-VALVE BODY SS 056874-14 1 2 103
+CLIP-RETAINER-MIX PUMP 044641 1 2 103
CYLINDER A.-PUMP-HOPPER-S.S. X57025 1 103
GASKET-SIMPLIFIED PUMP VALVE 053527 1 2 000
O-RING-2-1/8 OD X .139W-#225 020051 2 4 000
62
PIN A.-RETAINING X55450 1 2 103
+PIN-COTTER-HAIRPIN-1/8DIA 044731 1 2 103
PISTON 053526 1 2 103
RECEIVER A.-REFRIG.AC*C708/709 X59351 1 103
RELAY-3 POLE-20A-208/240 50/60 012725-33 1 2 103
RELAY-DPDT 100UA TO 7A 1/8HP 052111-03 1 2 103 BEATER INTERLOCK
RELAY-DPDT-24VAC-30A@277V 054703-03 2 103 HOT GAS SOLENOIDS
RELAY-MTR START TI#4CR-1-625 039725-27 1 2 103
SANITIZER KAY-5 125 PACKETS 041082 1 1 000
SHAFT A.-DRIVE-MIX PUMP-HOPPER X41947 1 2 103
O-RING-1-3/4 OD X .139W 008904 1 2 000
CRANK-DRIVE-HOPPER MIX PUMP 039235 1 2 103
SHAFT-DRIVE-MIX PUMP-HOPPER 041948 1 2 103
O-RING 1/2 ID X .139W 048632 2 4 000
SHAFT-BEATER *C706/C707* 056078 1 103
+SEAL-DRIVE SHAFT 032560 1 000
SHAFT-BEATER 032564 2 103
63
SWITCH A.-DRAW *C706* X56147 1 103
ARM A.-DRAW *C706* X56253 1 103
E-RING 3/16 .335 O.D. 049178 1 000
INSULATOR-SWITCH 1/64 ARMITE 029099 2 000
NUT-4-40 HEX -PLATED- 038623 2 000
PIN-PIVOT 015478 1 103
SCREW-4-40X1 RD HD STEEL-ZP 028890 2 000
SPRING-RETURN-LEFT-SELF CLOSE 041660 1 103
SPRING-RETURN-RIGHT-SELF CLOSE 041661 1 103
SWITCH-LEVER-SPDT-10A-125-250V 028889 2 103
SWITCH A.-DUAL LEVER X62400 1 103 s/n K5027279 & up - see Switch-Lever/Actuator
SWITCH-LEVER-SPDT-10A-125-25 028889 4 103
SCREW-4-40X1" TAPTITE PAN HD 045141 4 000
BRACKET-SWITCH*C712* 062394 2 103
ACTUATOR-TANDEM LEAF 062408 1 103
SWITCH A.-DRAW *SELF CLOSING* X59905 1 103 S/N K4115575 & PRIOR
ARM-SWITCH-DRAW-L 038649 1 103
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
ARM-SWITCH-DRAW-R 038650 1 103
Parts List
E-RING 1/4 032190 4 000
PIN-PIVOT-DRAW SWITCH 038484 1 103
ROD-SPRING RETAINER 038254 1 103
SCREW-4-40X1/2"TAPTITE PAN HD 042604 4 000
SPRING-EXTENSION.375X.045X1.00 038922 2 103
SPRING-RETURN-LEFT-TWIN TWIST 038923 1 103
SPRING-RETURN-RIGHT-TWIN TWIST 038924 1 103
SWITCH-LEVER-SPDT-11A-125-277V 039252 2 103
SWITCH-PRESSURE 440 PSI-SOLDER 048230 1 2 103 LINE A.-DISCHARGE
SWITCH-PRESS 220 CO/270 CI 064282 1 103
SWITCH-REED *DOOR INTERLOCK* 056249 1 1 103 K7072606 & PRIOR - BEATER INTERLOCK
SWITCH-REED*DOOR INTERLOCK*6 056771 1 103 K7085360 & UP - SEE INTERLOCK A.-DOOR
SWITCH-TOGGLE-DPDT*ON-NONE-ON 024295 1 103
TOOL-O-RING REMOVAL-FREEZER 048260-WHT 1 000
TOOL-SHAFT-DRIVE-PUMP-HOPPER 057167 1 1 000
64
TOOL-SHAFT-DRIVE-PUMP HOPR/LVB 047919 1 000
TRANS.-120/208/240V PRI 24VSEC 051660 1 103 SOLENOIDS
TRANS.-CONT.-32VA 120/200/240V 054834 1 103 INTERFACE BOARD
TRAY-DRIP *C706/C707*BLACK 056858 1 103
TRAY-DRIP-19-5/8 L X 4-7/8 033812 1 103
TRAY-DRIP *C716* 063877 1 103 HOLDS 033812 TRAY S/N K6024393 & UP
TRAY-PARTS-BARREL-3.4 QT TWIST 045755 1 103
TRAY-PARTS-BARREL-3.4 QT-17"HT 045756 1 000
TRAY-PARTS-PUMP-SIMPLIFIED SS 056525 1 2 000
TRIM-CORNER-REAR-LEFT *C708* 056964 1 103
TRIM-CORNER-REAR-RIGHT *C708* 056965 1 103
TRIM-CORNER-REAR-L 059896 1 103
TRIM-CORNER-REAR-R 059897 1 103
TUBE A.-FEED-HOPPER S.S. X56521 1 103 MIX PUMP
+RING-CHECK-FEED-TUBE 056524 1 000
+O-RING-11/16ODX.103W-RED 016132 2 000
TUBE A.-FEED-LEFT *C712/C717* X59808 1 103
65
VALVE-LIQUID INJ-HT GAS 057075-1 1 K7012344 & UP - LINE A.-DRYER/VALVES
VALVE-TREV 3/8X3/8 220 *161* 055378 1 2 103 K6112655 & PRIOR LINE A.-DRYER/VALVES
VALVE-TREV 1/4ODFX3/8 W/STRA 063951 2 LIQUID LINE
VIDEO-TRAIN C708/C709/C716/717 062069-V 1 1 000 USE 062069-DVD
VIDEO-TRVIDEO-TRAIN 062069-PAL 000 PAL=INTERNATIONAL FORMAT-MAY USE
C708/C709/C716/717 062069-DVD
WATER COOLED
BLOWER A. C712/C717 X62380-27G 1
BRACKET A.-MOUNTING CONDENSER X58931 1
BRACKET-VALVE-W/C *C708* / 058440 1
BRACKET-VALVE-W/C *C708* 058440 1 NNN
CONDENSER-WC-COAX 047540-1 1 103
CONDENSER-WC-COAX 047540 1 103
GUARD-BLOWER 022505 1 103
FAN-5 BLADE 7 " PUSH 30D 016289 1 103
HOSE-RUBBER 1/2"ID X 7/8"/ R50200 5 10 000
Parts List
DESCRIPTION PART C708 C716 WARR. REMARKS PARTS
NUMBER QTY. QTY. CLASS UPDATE
MANIFOLD-1/2S THRU-1/4S OUT- 046688 1 103
Parts List
MOTOR A.-FAN *C708* WC X59307-27 1 NNN
MOTOR-FAN 9 WATT 1550RPM-CW 012768-27 1 103
TERMINAL-MAL.SP.INS.18-22.25 026962 1 000
BRACKET-FAN *453/750* 038641 1 103
SCREW-8-36X3/8 SLOT HEX WASH 046137 5 000
ADAPTOR-3/8MP X 1/2 BARB- 011021 2 103
OUTLET A.-TEE X25900 1 103
PLATE-CONDENSER W/C 062043 1
PLATE A.-MOUNTING-COUPLING X58935 1
PLATE A.-MOUNTING-COUPLING X58935 1 103
PLATE-CONDENSER W/C 062043 1 103
SWITCH-PRESSURE 350 PSI-SOLD 048231 1 2 103
TEE-3/8" PIPE WATER VALVE 032953 1 103
VALVE-WATER 3/8 REG/HEAD 046686 1 2 103
66
TOP AIR DISCHARGE