Comutatoare
Comutatoare
Comutatoare
3 - Cam switches
1 Complete switches, 10 A
b Front mounting by Ø 16 or Ø 22 mm hole, with 30 x 30 mm front plate . . . page 3/8
v Switches and stepping switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/8
v Changeover switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/10
v Voltmeter and ammeter switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/12
2 Complete switches, 12 and 20 A
b Front mounting, “multi-fixing” or by Ø 22 mm hole, with 45 x 45 mm front plate
v Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/20
v Stepping switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/23
3 v
v
Reversing and changeover switches . . . . . . . . . . . . . . . . . . . . . . . . .
Ammeter switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 3/29
page 3/30
v Voltmeter switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/32
5 v
v
Paralleling switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/44
Stepping switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3/46 and 3/59
v Ammeter switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/56
v Voltmeter switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/57
v Multi-circuit switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/60
v Reversing switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/61
6 v
v
Star-delta switches and reversing star-delta switches . . . . . . . . . . . . page 3/62
Pole change switches and reversing pole change switches . . . . . . . . page 3/63
b Operating heads
10
3/0
0
3/1
Selection guide 3
Cam switches 3
Type K
Applications Used in building control panels and consoles, type K cam switches allow
control of processes and utilities in industry and buildings and direct control
1 Functions
for simple machines.
Operating heads Black standard handle Black and red standard and long handles
Metallic legend, black marking Key operator
Metallic head
Metallic legend with black marking or
9 Approvals cULus
black legend with white marking
UL-CSA
EN/IEC 60947-3 EN/IEC 60947-3
EN/IEC 60947-5-1 EN/IEC 60947-5-1
Type Type K10 Type K1/K2
Cam switch model K10 p K1 p
10 Pages 3/8 to 3/12 3/20 to 3/73 and 3/80 to 3/85
3/2
3
3
1
1 to 6-pole 1 to 6-pole
2 to 12-position, 1 to 4-pole –
1 to 5-pole 1 to 4-pole
– –
2 and 3-pole 2 and 3-pole
Star-delta Star-delta 2
2 and 3-speed 2-speed
5
20 A 32 A 50 A 63 A 115 A 150 A
690 V 690 V 690 V 690 V 690 V 690 V
AC-3 - 3-phase AC-3 - 3-phase AC-3 - 3-phase AC-3 - 3-phase AC-3 - 3-phase AC-3 - 3-phase
230 V - 2.2 kW - 8.3 A 230 V - 5.5 kW 230 V - 7.5 kW 230 V - 11 kW 230 V - 15 kW 230 V - 22 kW
AC-15 AC-15 AC-15 – – –
230 V - 4 A 230 V - 14 A 230 V - 16 A
IP 40 6
Complete switches
– 7
By 4 holes on 48 mm centres By 4 holes on 68 mm centres
64 x 64 88 x 88 8
Black standard handle
Metallic legend, black marking
9
cULus
EN/IEC 60947-3
Type K30...K150
K2 p K30 p K50 p K63 p K115 p K150 p
3/20 to 3/73 3/88 to 3/92 10
3/3
Presentation 3
Cam switches 3
Series K
Functions panorama
2
OFF-ON with spring return from 120° to 90° –
OFF-ON with spring return from 30° and from 330° to “0” position –
OFF-ON with 45° switching angle –
OFF-ON with momentary-contact function –
paralleling with “0” position –
OFF-ON changeover with spring return from 240° to 270° and –
from 120° to 90°
10 pole change –
3/4
3
2
3/22 – 3/36 –
3/22 – 3/37 –
– – 3/36
– – 3/37 –
– – 3/44, 3/45 –
– – 3/37 –
– – – – 3
– – – –
3/23, 3/24 – – –
3/25, 3/26 – – –
3/27, 3/28 – – –
– – 3/46, 3/47, –
–
–
–
–
3/48, 3/49
3/50, 3/51
–
– 4
– – 3/52, 3/53 –
– – 3/54, 3/55 –
– – 3/59 –
– 3/80 – –
– 3/81 – –
–
–
3/82
3/83
–
–
–
–
5
– 3/83 – –
– – – –
– – 3/38, 3/39 3/90
3/29 – – –
3/29
–
–
3/85
–
–
–
–
6
– – 3/62, 3/63 3/91
– – 3/64 –
– – 3/41, 3/42 –
– – 3/42, 3/43 –
– – 3/60 –
– – 3/62 –
8
– – 3/40, 3/61 3/92
– – 3/61 –
3/29 – 3/40 –
– – 3/40 –
– – 3/40 –
–
–
–
–
3/63, 3/64
3/65
3/92
–
9
– 3/84 – –
– 3/85 – –
– – – 3/91
– – – 3/92
10
3/5
General 3
Cam switches 3
Complete switches, 10 A
The range of K10 cam switches (10 A rating) comprises only complete switches.
These products are more specifically designed for process control applications:
1 b compact size,
b easy to integrate with other Ø 16 and Ø 22 mm units,
b selection functions.
b switches
2 b
b
stepping switches
reversing switch
b changeover switches
b voltmeter switches 0
b ammeter switches 2
1 0
3
3
4
By Ø 16.3 or Ø 22.3 mm hole
0
2
6 1
10
3/6
Characteristics 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
Environment
Conformity to standards EN/IEC 60947-3
EN/IEC 60947-5-1
UL 508 1
Product certifications cULus
3
Degree of protection IP 65 conforming to IEC 60529 (operating head)
IP 20 (contact block)
AC-21A, AC-1 –
120 V
400 V
6A
10 A
4
UL/Canada 3-phase 110/120 V 0.75 hp
Heavy Duty 220/240 V 1 hp
A300
single-phase 110/120 V 0.33 hp
220/240 V 0.75 hp
5
AC-23A 3-phase 220/240 V 1.8 kW
single-phase 110/120 V 0.37 kW
220/240 V 0.75 kW
d.c. current Ie 1 contact 24 V 10 A
resistive load 110 V 0.7 A
220 V 0.3 A
Short-circuit protection 10 A cartridge fuse type gG
Electrical reliability Failure rate < 1 fault for 100 million operating cycles (c 24 V PLC inputs) 8
Connection Captive screw clamp terminals
Clamping capacity: 2 x 1.5 mm2
10
3/7
References 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
2
5
6 2 K10 B002ACH 0.035
K10 B002ACH 7 0
8 60
3 3-pole
4-pole
5
6
7
8 4 K10 D004ACH 0.045
4
and and switch of
switching programme position steps kg
L1
1 2 2 + “0” K10 B002QCH 0.035
1
2 0 position
3
4
1 2
5 270 330 30
1
2
330
270
30
3
4
6 1
L1
1
2
3 3 + “0” K10 C003QCH 0.045
0 position
2
3
4
5
6
12 3 0
315 45
7
270
270 315 0 45
1
2
3
4
5
6
L1
2 34 4 + “0” K10 D004QCH 0.045
8
1
1 0 position
550258
2
3
4
5
6
7 0 30
8 330
300
K10 D004QCH 270
1 2 3 4
10
3/8
References (continued) 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
1
2 0 position
3
4
5
6
K10 D012QCH
7
8
1 2
330 30 2
270 330 30 270
1
2
3
4
5
6
7
8
3
L1 L2 2
1 1 3 3 + “0” K10 F013QCH 0.055
2 0 position
3
4
5
6
7
8
9
10
11
315
270
0
45 4
12
1 2 3
270 315 0 45
1
2
3
4
5
5
6
7
8
9
10
11
12
1
L1
1
2 3 3 K10 C003NCH 0.045 6
2
3
4
5
6 330 30
12 3 270
270 330 30
7
1
2
3
4
5
6
L1
2 3 4 K10 D004NCH 0.045
1
8
1 4
2
3
4
5
6
7 330 30
8
270 90
1 2 3 4
270 330 30 90
1
9
2
3
4
5
6
7
8
10
3/9
References (continued) 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
1 L1 L2
2
2 3 3 K10 F013NCH 0.055
3 1
4
5
6
7
8
2
9
10
11 330 30
12 1 2 3
270 330 30 270
1
2
3
4
5
6
7
8
9
10
11
3 12
4
and and switch of
switching programme position poles kg
1
2
3
4
1 2
330 0 30
1
2
3
4
10
3/10
References (continued) 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
5
6
2-pole 7
8
9
10
3-pole 11
12
13
14
K10 F003UCH 4-pole 15 4 K10 H004UCH 0.065
16
4
Changeover switches without “0” position
L/1 2 3 4 1 2 1 K10 B011UCH 0.035
1
2
3
4
5
6
7
8
9 330 30
5
10 2 K10 D012UCH 0.045
11
12
13
14
15
16 1 2
330 30
6
1
2
1-pole 3 3 K10 F013UCH 0.055
4
5
6
2-pole 7
8
9
10
3-pole 11
12
13
14
4-pole 15 4 K10 H014UCH 0.065
16
10
3/11
References (continued) Cam switches
3
3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
Voltmeter switches
For measurements between 3 phases and between 1 phase and neutral
1 Wiring diagram
and
Marking
and switch
Reference Weight
1 L1-L2 0 L1-N
K10 F027MCH 0.055
2 L2-L3
L3-L1
L2-N
L3-N
3
4
2 K10 F027MCH
5
6
7
8 0
9 315 45
10
270 90
11
12 225 135
V
3
270 300 330 0 30 60 90
1
2
3
4
5
6
7
8
9
10
11
12
3
4
5
6
5 7
8
V
315
270
0
45
270 315 0 45
1
2
3
4
5
6
6
7
8
Ammeter switches
For 3 circuits, with “0” position
550263
L1
L2 0 K10 F003MCH 0.055
7
L3 3 1
PE
2
1
2
K10 F003MCH 3
4 0
5 A
6 270 90
7
8 180
9
8
10
11
12
0 90 180 270
1
2
3
4
5
6
7
8
9
9 10
11
12
10
3/12
Dimensions 3
Cam switches 3
Complete switches, 10 A
Front mounting by Ø 16 or Ø 22 mm hole
With 30 x 30 mm front plate
Cam switches, 10 A
1
30
28
25 e
a 2
a
K10 A, B 51
K10 C, D 63
K10 F 75
K10 H 87
3
e: support panel thickness 0.5 to 5 mm.
1,7 3,2
4
12,7
9,8
16,2 22,3
5
Convention used for switching programme representation
Link positions (factory mounted) Graphic representation of switching positions and spring return to “0” position
L1 L2 L3
6
315 0 45
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10 Contact terminal reference number
UVW
Contact closed
7
Contact closed in 2 positions and maintained between
the 2 positions
315
0
45 8
Overlapping contacts
10
3/13
General 3
Cam switches 3
The cam switch range comprises the equally dimensioned and similar looking
products of the K1 (12 A rating) series and K2 (20 A rating) series.
1 Both series feature complete switches and adaptable sub-assemblies for user
assembly.
Complete switches
Front mounting
- switches
- stepping switches (2 to 5 step)
- reversing and 1 to 4-pole changeover switches
4
“Multi-fixing” By Ø 22 mm hole Front mounting by 6 screws
Ø 5.2 mm and 55 x 100 mm
front plate
K1p pppppH, K2p pppppH K1p pppppH, K2p pppppH K1p ppppZp
5 See pages 3/20 to 3/27 See pages 3/20 to 3/27 See pages 3/80 to 3/85
7
“Multi-fixing” With blank legend With marked legend Without legend
K1p pppppL, K2p pppppLL KpG 3H KCG 3H KDG 3H
See pages 3/34 to 3/65 See page 3/66 See page 3/66 See page 3/66
Head sub-assembly
8 b With 45 x 45 mm front plate, 35 mm handle and padlocking device
3/14
General (continued) 3
Cam switches 3
With Ø 22 mm hole With blank legend With marked legend (1) Without legend
K1p ppppp, K2p pppppL KpC 1H KpC 1pp KDC 1pp
See pages 3/34 to 3/65 See page 3/66
Head sub-assembly
See page 3/66 See page 3/66
3
b With 45 x 45 mm front plate and key operator
4
With blank legend Without legend
KpC 1p KDC 1p
See page 3/66 See page 3/66
Head sub-assembly
b With 60 x 60 mm front plate and 42 mm handle
5
6
With blank legend With marked legend Without legend
KpD 1H KCD 1pp KDD 1H
See page 3/66 See page 3/66 See page 3/66
Head sub-assembly
b With 60 x 60 mm front plate and key operator
7
8
With blank legend Without legend
KpD 1p KDD 1p
See page 3/67 See page 3/67
Head sub-assembly
b Circular with plastic bezel
9
3/15
General (continued) 3
Cam switches 3
3 With Ø 22 mm hole and metal mounting plate Standard handle Long handle Key operator
K1p ppppK, K2p ppppX KAX Z1M1p KAX Z1C1p KAX Z1S1pp
See pages 3/34 to 3/65 See page 3/67 See page 3/67 See page 3/67
Rear mounting
Body sub-assembly Head sub-assembly
With 4 holes With blank legend With marked legend (1) Without legend
Accessories
9 Various accessories complement the K1 - K2 cam switch range: legends, legend holders,
terminal covers, seals, etc. See pages 3/68 to 3/73.
10
3/16
General (continued) 3
Cam switches 3
The cam switches are available to suit various mounting and fixing methods.
Fixing
Front mounting
By means of “multi-fixing”
1
front plate, using 2 or 4
screws
36 36
30 36 36
2
90
30 35
12,2
6
Ø 22.5 mm cut-out. Ø 22.5 mm cut-out with anti-rotation notch.
Head attaches to plate using 1/4 turn bayonet locking and Head clips into body and secured on panel by fixing nut.
secured on panel by 2 needle screws.
Rear mounting 7
By means of 4 holes
3/17
Characteristics 3
Cam switches 3
Characteristics
Environment
1 Cam switch type
Conformity to standards For control circuits
K1
EN/IEC 60947-5-1
K2
UL 508
CSA C22-2 n° 14
For power circuits IEC/EN 60947-3
UL 508
CSA C22-2 n° 14
5 Degree of protection Conforming to IEC 60529 IP 40, for fixing by front plate and 4 screws
IP 65, with additional seal
10
3/18
Characteristics (continued) 3
Cam switches 3
Characteristics (continued)
Contact blocks
Cam switch type
Rated insulation Conforming to IEC 60947-1 V
K1
690
K2
690
1
voltage (Ui) degree of pollution 3
Rated impulse
withstand voltage
Conforming to IEC 60947-1 (Uimp) kV 6
7
In “isolating” function (Uimp) kV 4
10
3/19
References 3
Cam switches 3
2
2
3 3 12 K1C 003ALH 0.133
4 0
5 45 20 K2C 003ALH 0.133
Kpp ppppLH 6
7 4 12 K1D 004ALH 0.138
8
9 20 K2D 004ALH 0.138
10
11 5 12 K1E 005ALH 0.158
12 20 K2E 005ALH 0.158
U V W N U V
6 12 K1F 006ALH 0.168
3 Output 1 Output 2
20 K2F 006ALH 0.168
4
6
4-pole 7 3 12 K1C 003ACH 0.153
8
5-pole 9 20 K2C 003ACH 0.153
10
Kpp ppppCH 6-pole 11
12
4 12 K1D 004ACH 0.158
20 K2D 004ACH 0.158
5 12 K1E 005ACH 0.178
20 K2E 005ACH 0.178
6 12 K1F 006ACH 0.188
5 20 K2F 006ACH 0.188
6
3
4 20 K2C 003HLH 0.135
5
6 4 12 K1D 004HLH 0.140
7 0 20 K2D 004HLH 0.140
8
U V W N
90
7
2
2-pole 3 3 12 K1C 003HCH 0.155
3-pole 4
5 20 K2C 003HCH 0.155
4-pole 6
4 12 K1D 004HCH 0.160
7
8
20 K2D 004HCH 0.160
10
3/20
References (continued) 3
Cam switches 3
0 30
1
2
3
OFF-ON switches with spring return from 30° to “0” position
“Multi-fixing” 1 12 K1A 001TLH 0.105
L1 0 1 20 K2A 001TLH 0.105
By Ø 22 mm 1 12 K1A 001TCH 0.125
hole 20 K2A 001TCH 0.125
1
2 4
Kpp ppppCH K 0 30
N
0 30
1
2 5
10
3/21
References (continued) 3
Cam switches 3
Kpp ppppLH 0
K
90
N
120
0 90 120
3 1
2
3
4
OFF-ON switches with spring return from 30° and from 330° to “0” position
“Multi-fixing” 1 12 K1B 004TLH 0.115
L1 2 0 1 20 K2B 004TLH 0.115
4 1
2
3
By Ø 22 mm
hole
1 12
20
K1B 004TCH
K2B 004TCH
0.135
0.135
4 K
Kpp ppppCH
K 330 0 30
5 330 0 30
1
2
3
4
10
3/22
References (continued) 3
Cam switches 3
2
3
2 4 20 K2B 002QCH 0.135
5 0
6
Kpp ppppLH 3 45
7 90
4 8
9
5 10
1 2 3 4 5
3 step +“0”
3
0 45 90 135 180 225
1
0 1 “Multi-fixing” 12 K1C 003QLH 0.135
2
3
2 20 K2C 003QLH 0.135
2 4
5 3 By Ø 22 mm hole 12 K1C 003QCH 0.155
3 6
7 20 K2C 003QCH 0.155
4 8
4
9 0
Kpp ppppCH 5 10 45
90
135
4 step +“0” 5
“Multi-fixing” 12 K1D 004QLH 0.140
0 1
20 K2D 004QLH 0.140
2
By Ø 22 mm hole 12 K1D 004QCH 0.160
4 3
20 K2D 004QCH 0.160
6
0
45
90
135
180
7
5 step +“0”
0 1 “Multi-fixing” 12 K1E 005QLH 0.160
2 20 K2E 005QLH 0.160
5 4 3 By Ø 22 mm hole 12 K1E 005QCH 0.180
20 K2E 005QCH 0.180
0
45
90
225
180
135
8
10
3/23
References (continued) 3
Cam switches 3
2
3
2 4 20 K2B 002NCH 0.135
5
Kpp ppppLH 3 6 0
45
7
4 8
9
5 10
1 2 3 4 5
3
3 step
0 45 90 135 180
1
1 2 “Multi-fixing” 12 K1C 003NLH 0.135
2
3
3 20 K2C 003NLH 0.135
2 4
5 By Ø 22 mm hole 12 K1C 003NCH 0.155
3 6
20 K2C 003NCH 0.155
4
7
4 8
9
Kpp ppppCH 5 10 0
45
90
5
4 step
1 2 “Multi-fixing” 12 K1D 004NLH 0.140
3 20 K2D 004NLH 0.140
4 By Ø 22 mm hole 12 K1D 004NCH 0.160
20 K2D 004NCH 0.160
6 0
45
90
135
7 5 step
1 2 “Multi-fixing” 12 K1E 005NLH 0.160
3 20 K2E 005NLH 0.160
5 4 By Ø 22 mm hole 12 K1E 005NCH 0.180
20 K2E 005NCH 0.180
8 0
45
90
135
180
10
3/24
References (continued) 3
Cam switches 3
2
4
5
6
20 K2D 012QCH 0.160
7
2 8 0
Kpp ppppLH 9 45
10
11 90
3 12
13
14
15
4 16
17
18
3
19
5 20
1 2 3 4 5
3 step +“0”
0 45 90 135 180 225
0 1 “Multi-fixing” 12 K1F 013QLH 0.170
1
2
2 20 K2F 013QLH 0.170
3
4 3 By Ø 22 mm hole 12 K1F 013QCH 0.190
4
5
6 20 K2F 013QCH 0.190
7
2 8
Kpp ppppCH 9 0
45
10
11 90
3 12
13 135
14
15
4 16
17
18
19
5
5 20
4 step +“0”
0 1 “Multi-fixing” 12 K1H 014QLH 0.195
2 20 K2H 014QLH 0.195
4 3 By Ø 22 mm hole 12 K1H 014QCH 0.215
20 K2H 014QCH 0.215
0
45 6
90
135
180
5 step +“0”
7
0 1 “Multi-fixing” 12 K1K 015QLH 0.225
2 20 K2K 015QLH 0.225
5 4 3 By Ø 22 mm hole 12 K1K 015QCH 0.245
20 K2K 015QCH 0.245
0
8
45
90
225 135
180
10
3/25
References (continued) 3
Cam switches 3
2
4
5 20 K2D 012NCH 0.160
6 0
7 45
2
Kpp ppppLH 8
9
10
11
3 12
13
14
15
4 16
17
18
3
19
5 20
1 2 3 4 5
3 step
1
0 45 90 135 180 2
“Multi-fixing” 12 K1F 013NLH 0.170
1
2
3
3
20 K2F 013NLH 0.170
4
5 By Ø 22 mm hole 12 K1F 013NCH 0.190
6
20 K2F 013NCH 0.190
4 Kpp ppppCH
2
7
8
9
10
0
45
90
11
3 12
13
14
15
4 16
17
18
19
5 20
5
4 step
1 2 “Multi-fixing” 12 K1H 014NLH 0.195
3 20 K2H 014NLH 0.195
4 By Ø 22 mm hole 12 K1H 014NCH 0.215
20 K2H 014NCH 0.215
6 0
45
90
135
7 5 step
1 2 “Multi-fixing” 12 K1K 015NLH 0.225
3 20 K2K 015NLH 0.225
5 4 By Ø 22 mm hole 12 K1K 015NCH 0.245
20 K2K 015NCH 0.245
8
0
45
90
135
180
10
3/26
References (continued) 3
Cam switches 3
2
5
6
7
20 K2F 022QCH 0.190
8 0
9 45
Kpp ppppLH 10
90
11
12
1 2
0 45 90
1
2
3
3
4
5
6
7
8
9
10
11
12
3 step +“0”
0 1 “Multi-fixing” 12 K1I 023QLH 0.215
4
L1 L2 L3
1
2
2 20 K2I 023QLH 0.215
3
4 3 By Ø 22 mm hole 12 K1I 023QCH 0.235
5
6
7
20 K2I 023QCH 0.235
8 0
9 45
Kpp ppppCH 10
11 90
12
13 135
14
15
5
16
17
18
1 2 3
0 45 90 135
1
2
3
4
5
6
7
6
8
9
10
11
12
13
14
15
16
17
18
10
3/27
References (continued) 3
Cam switches 3
2
5
6 20 K2F 022NCH 0.190
7
8 0
9 45
Kpp ppppLH 10
11
12
1 2
0 45
1
3
2
3
4
5
6
7
8
9
10
11
12
3 step
4
1
L1 L2 L3
2 “Multi-fixing” 12 K1I 023NLH 0.215
1
2
3 20 K2I 023NLH 0.215
3
4 By Ø 22 mm hole 12 K1I 023NCH 0.235
5
6
7
20 K2I 023NCH 0.235
8 0
9 45
Kpp ppppCH 10
11 90
12
13
14
5
15
16
17
18
1 2 3
0 45 90
1
2
3
4
5
6
6
7
8
9
10
11
12
13
14
15
16
17
18
10
3/28
References (continued) 3
Cam switches 3
Reversing switches with spring return from 315° and from 45° to “0” position
Wiring diagram Marking Front Number Thermal Reference Weight
and
switching programme
and switch
position
mounting
method
of poles current
(lth) 1
A kg
L1 0 “Multi-fixing” 1 12 K1B 006TLH 0.115
2 1
20 K2B 006TLH 0.115
By Ø 22 mm 1 12 K1B 006TCH 0.135
1 hole 20 K2B 006TCH 0.135
2
2 0
3 315 45
Kpp ppppLH 4
K1 K2
K2 K1
N
3
315 0 45
1
2
3
4
6
3 20 K2F 003UCH 0.190
4
2-pole 5 4 12 K1H 004UCH 0.215
6
7
8
20 K2H 004UCH 0.215
3-pole 9
10
11
12
4-pole 13
14
15
16
9
1 2
20 K2D 012UCH 0.160
330 30 3 12 K1F 013UCH 0.190
1-pole 1
2 20 K2F 013UCH 0.190
3
4
5
4 12 K1H 014UCH 0.215
2-pole 6
7 20 K2H 014UCH 0.215
8
3-pole 9
10
10
11
12
4-pole 13
14
15
16
3/29
References (continued) 3
Cam switches 3
Complete switches, 12 A
Front mounting, “multi-fixing” or by Ø 22 mm hole
With 45 x 45 mm front plate, 35 mm handle and metallic
legend with black marking
Ammeter switches
Wiring diagram Marking Front Thermal Reference Weight
1 and
switching programme
and switch
position
mounting
method
current
(lth)
A kg
For 3 circuits
With “0” position
K L 0
L1
K I K L
“Multi-fixing” 12 K1F 003MLH 0.170
L2 L3 L1
K I K L
2
L3
K I
L2 By Ø 22 mm 12 K1F 003MCH 0.190
1 hole
2
Kpp ppppLH 3 0
4
5 270 90
6
7
8 180
9
10
11 A
3 12
0 90 180 270
1
2
3
4
5
6
7
4
8
9
Kpp ppppCH 10
11
12
5
K I K L L2
L3
K I By Ø 22 mm 12 K1F 013MCH 0.190
L3
1 hole
2
3 0
4
5
6 90
7
8 180
9
10
6
11 A
12
0 90 180
1
2
3
4
5
6
7
7 8
9
10
11
12
10
3/30
References (continued) 3
Cam switches 3
Complete switches, 12 A
Front mounting, “multi-fixing” or by Ø 22 mm hole
With 45 x 45 mm front plate, 35 mm handle and metallic
legend with black marking
2
L3 4 2
L4
K I K L
3 By Ø 22 mm 12 K1H 004MCH 0.215
K I
hole
1
2 0
3
60
Kpp ppppLH 4
5
6
7 240 120
8 180
9
10
11
12
3
13
14
15 A
16
Kpp ppppCH
7
8
9
4
10
11
12
13
14
15
16
L1 “Multi-fixing”
Without “0” position
12 K1H 014MLH 0.195
5
K L
L1
K I K L L4 L2
L2
K I K
L3
K
L
L3
By Ø 22 mm 12 K1H 014MCH 0.215
I K L
L4
K I
hole
1
2 0
3
6
4
5 270 90
6
7
8 180
9
10
11
12
13
14
15 A
16
0 90 180 270
1
2
7
3
4
5
6
7
8
9
10
8
11
12
13
14
15
16
10
3/31
References (continued) 3
Cam switches 3
Complete switches, 12 A
Front mounting, “multi-fixing” or by Ø 22 mm hole
With 45 x 45 mm front plate, 35 mm handle and metallic
legend with black marking
Voltmeter switches
Wiring diagram Switching programme Marking Front Thermal Reference Weight
1 and
switch
mounting current
method (lth)
position
A kg
For measurements between 3 phases and neutral
L1 2 3 N 0 45 90 135 0 L1-N With “0” position
1
2 L2-N “Multi- 12 K1D 023MLH 0.140
2
1
2 3 fixing”
4 L3-N
3
4 5
5 6 By 12 K1D 023MCH 0.160
0
Kpp ppppLH 6 7 45 Ø 22 mm
7 8
90 hole
8
135
V
3
0 45 90 Without “0” position
1 L1-N “Multi- 12 K1D 033MLH 0.140
2 L2-N
3 L3-N fixing”
4
5
4 Kpp ppppCH
6
7
8
0
45
By
Ø 22 mm
12 K1D 033MCH 0.160
90
hole
8
270 90
11
12 210 150
13
14
15
16
10
3/32
References (continued) 3
Cam switches 3
Complete switches, 12 A
Front mounting, “multi-fixing” or by Ø 22 mm hole
With 45 x 45 mm front plate, 35 mm handle and metallic
legend with black marking
L3-L1
L2-N
L3-N
fixing”
2
5 6 By 12 K1F 027MCH 0.190
Kpp ppppLH 6 7
0
Ø 22 mm
7 8
8 9
315 45 hole
9 10 270 90
10 11
225 135
11 12
12
V
4
8
Kpp ppppCH 9 270 90 hole
10
11 210 150
12
315 0 45 90
1 L1-L2
“Multi-
Without “0” position
12 K1E 035MLH 0.160
9
2 L1-N L2-L3
3 L3-L1 fixing”
4
5
6 By 12 K1E 035MCH 0.180
7
315
0
45
Ø 22 mm
8
9 hole
90
10
10
3/33
References 3
Cam switches 3
1-pole
0 Front Multi-fixing KpA 001AL 0.091
Input 1 Input 2 45
By Ø 22 mm hole KpA 001A 0.075
L1 L2 L3 N L1 L2 L3 N
KpA 001AX (2) 0.153
1
2 Rear KpA 501A 0.115
2 Kpp 0pppL
3
4
5
6
7 2-pole
8
9
0
45
Front Multi-fixing KpB 002AL 0.101
10 By Ø 22 mm hole KpB 002A 0.085
11
12 KpB 002AX (2) 0.163
13
Rear KpB 502A 0.125
3
14
15
16
U V W N U V W N
3-pole
Output 1 Output 2
0 Front Multi-fixing KpC 003AL 0.121
45
By Ø 22 mm hole KpC 003A 0.105
0 45
1 KpC 003AX (2) 0.183
1-pole 2
Rear KpC 503A 0.140
4
3
4 2-pole
5
3-pole 6
7
Kpp 0ppp 8 4-pole
5-pole
9
10
4-pole
11
12 6-pole
0
45
Front Multi-fixing KpD 004AL 0.126
13
7-pole 14 By Ø 22 mm hole KpD 004A 0.110
15
16 8-pole KpD 004AX (2) 0.188
Rear KpD 504A 0.150
5
5-pole
0 Front Multi-fixing KpE 005AL 0.146
45
By Ø 22 mm hole KpE 005A 0.130
KpE 005AX (2) 0.208
Kpp 5ppp
6-pole
0 Front Multi-fixing KpF 006AL 0.156
45
By Ø 22 mm hole KpF 006A 0.140
KpF 006AX (2) 0.218
7-pole
0 Front Multi-fixing KpG 007AL 0.176
45
By Ø 22 mm hole KpG 007A 0.160
Rear KpG 507A 0.190
8
Kpp 0pppX
8-pole
0 Front Multi-fixing KpH 008AL 0.181
45
By Ø 22 mm hole KpH 008A 0.165
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1A 001A.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2A 001A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
10 KAX Z1ppp.
3/34
References (continued) 3
Cam switches 3
Kpp 0pppL
U V
3-pole 2
L1 L2 L3 0 90 0 Front Multi-¿xing KpC 003HL 0.121
1 1 By Ø 22 mm KpC 003H 0.105
2 2
3 3 90 hole KpC 003HX (2) 0.183
4 4
5 5 Rear KpC 503H 0.140
6 6
U V W 3-pole with neutral wire terminal and Earth terminal
0 Front Multi-¿xing KpC 023HL 0.121 3
By Ø 22 mm KpC 023H 0.105
90 hole KpC 023HX (2) 0.183
Rear KpC 523H 0.140
4-pole
1
L1 L2 L3 N
0 90
1
2
0 Front Multi-¿xing
By Ø 22 mm
KpD 004HL
KpD 004H
0.126
0.110
4
Kpp 0ppp 2 90 hole
3 3 KpD 004HX (2) 0.188
4 4
5 5 Rear KpD 504H 0.150
6 6
7 7
8 8 4-pole with neutral wire terminal and Earth terminal
U V W N 0 Front Multi-¿xing KpD 024HL 0.126
90
By Ø 22 mm
hole
KpD 024H
KpD 024HX (2)
0.110
0.188
5
Rear KpD 524H 0.150
5-pole
Input 1 Input 2
0 90 0 Front Multi-¿xing KpE 005HL 0.146
L1 L2 L3 L1 L2 1 By Ø 22 mm KpE 005H 0.130
2
1
2
3
3
4
5
90
Rear
hole KpE 005HX
KpE 505H
(2) 0.208
0.165
6
Kpp 5ppp 4 6
5 7
6 8 5-pole with neutral wire terminal and Earth terminal
7 9
8 10 0 Front Multi-¿xing KpE 025HL 0.146
9 By Ø 22 mm KpE 025H 0.130
10 hole
90
7
U V W U V
Rear KpE 525H 0.165
Output 1 Output 2
6-pole
Input 1 Input 2 0 Front Multi-¿xing KpF 006HL 0.156
0 90 By Ø 22 mm KpF 006H 0.140
L1 L2 L3 L1 L2 L3 1
90 hole
2 KpF 006HX (2) 0.218
1 3
2 4 Rear KpF 506H 0.175
8
3 5
4 6
7 6-pole with neutral wire terminal and Earth terminal
5 8
Kpp 0pppX 6 9 0 Front Multi-¿xing KpF 026HL 0.156
7 10
8 11 By Ø 22 mm KpF 026H 0.140
9 12 90 hole
10 Rear KpF 526H 0.175
11
12
U V W U V W
Output 1 Output 2
9
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1C 003H.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2C 003H.
(2) Bodies using the Ø 22 mm hole mounting method that can be ¿tted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/35
References (continued) 3
Cam switches 3
4 1
2
Rear KpA 501T 0.115
Kpp 0ppp
K
7
OFF-ON switches with spring return from 120° to 90°
Wiring diagram Switching Switch Mounting method Reference, to Weight
programme position be completed kg
(1)
Front Multi-¿xing KpB 003TL 0.101
9 N
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1A 001A.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2A 001A.
(2) Bodies using the Ø 22 mm hole mounting method that can be ¿tted with chromium plated metal bezel operating heads, type
10 KAX Z1ppp.
3/36
References (continued) 3
Cam switches 3
OFF-ON switches with spring return from 30° and from 330° to “0” position
Wiring diagram Switch position Mounting method Reference, to Weight
and
switching programme
be completed
(1)
kg
1
Front Multi-fixing KpB 004TL 0.101
L1
330 0 30
By Ø 22 mm hole KpB 004T 0.085
1 Rear KpB 504T 0.115
2
3
4 K
Kpp 0pppL
K
2
N
330 0 30
1
3
2
3
4
L1 0
Front Multi-fixing
By Ø 22 mm hole
KpB 001DL
KpB 001D
0.101
0.085
4
1 90
KpB 001DX (2) 0.163
2
3 Rear KpB 501D 0.125
4 K
Kpp 0ppp
K
N 5
0 90
1
2
3
4
6
OFF-ON changeover switches with spring return from 240° to 270° and from 120° to 90°
Wiring diagram Switch position Mounting method Reference, to Weight
and be completed kg
switching programme (1)
Front Multi-fixing KpD 005TL 0.126
0 By Ø 22 mm hole KpD 005T 0.110
7
L1 L2
270 90
240 120
1
2 Rear KpD 505T 0.150
Kpp 5ppp 3
4
5
6
7
8 K1 K2
K1 K2 8
N N
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 004T.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2B 004T.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/37
References (continued) 3
Cam switches 3
1-pole
L/1 2 3 4 5 Front Multi-fixing KpB 001UL 0.101
0
1 315 45 By Ø 22 mm hole KpB 001U 0.085
2
3 KpB 001UX (2) 0.163
4
5 Rear KpB 501U 0.125
2
6
7
Kpp 0pppL 8
9
10
11
12
13
14
15
2-pole
16
17 Front Multi-fixing KpD 002UL 0.126
18 0
19 315 45 By Ø 22 mm hole KpD 002U 0.110
20
3 1 2
KpD 002UX (2) 0.188
Rear KpD 502U 0.150
315 0 45
1-pole 1
2
3
4
3-pole
2-pole 5 Front Multi-fixing KpF 003UL 0.156
4
6
7 315
0
45 By Ø 22 mm hole KpF 003U 0.140
8
3-pole 9 KpF 003UX (2) 0.218
Kpp 0ppp 10
11 Rear KpF 503U 0.175
12
4-pole 13
14
15
16
5-pole 17
18
5 19
20
4-pole
0
Front Multi-fixing KpH 004UL 0.181
315 45 By Ø 22 mm hole KpH 004U 0.165
KpH 004UX (2) 0.243
Rear KpH 504U 0.195
6 5-pole
Kpp 5ppp
Front Multi-fixing KpK 005UL 0.211
0
315 45 By Ø 22 mm hole KpK 005U 0.195
KpK 005UX (2) 0.273
Rear KpK 505U 0.210
7
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 001U.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2B 001U.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
8 KAX Z1ppp.
Kpp 0pppX
10
3/38
References (continued) 3
Cam switches 3
2
6
7
Kpp 0pppL 8
9
10
11 2-pole
12
13
14
Front Multi-fixing KpD 012UL 0.126
15
16
330 30
By Ø 22 mm hole KpD 012U 0.110
17
18 KpD 012UX (2) 0.188
19
Rear KpD 512U 0.150
3
20
1 2
330 30
3-pole
1-pole 1 Front Multi-fixing KpF 013UL 0.156
2
3
330 30
By Ø 22 mm hole KpF 013U 0.140
4
2-pole 5 KpF 013UX (2) 0.218
6
Rear KpF 513U 0.175
4
7
8
3-pole 9
10
Kpp 0ppp 11
12
13
4-pole
4-pole 14 Front Multi-fixing KpH 014UL 0.181
15
16 330 30
By Ø 22 mm hole KpH 014U 0.165
5-pole 17
18 KpH 014UX (2) 0.243
19
Rear KpH 514U 0.195
5
20
5-pole
Front Multi-fixing KpK 015UL 0.211
330 30
By Ø 22 mm hole KpK 015U 0.195
KpK 015UX (2) 0.273
Rear KpK 515U 0.220
6
Kpp 5ppp
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 011U.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2B 011U.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
7
8
Kpp 0pppX
10
3/39
References (continued) 3
Cam switches 3
2 Kpp 0pppL
K1 K2
K2 K1
Reversing switches with spring return from 315° and from 45° to “0” position
3 Wiring diagram Switching Switch position Mounting method Reference, to Weight
programme be completed (1) kg
L1 315 0 45 0 Front Multi-fixing KpB 006TL 0.101
315 45
1
2
By Ø 22 mm KpB 006T 0.085
3 hole KpB 006TX (2) 0.163
4
1
4
2 Rear KpB 506T 0.125
3
4
Kpp 0ppp
K1 K2
K2 K1
5 N
7 K1 K2
Reversing switches with spring return from 240° to 270° and from 120° to 90° position
Wiring diagram Switching Switch position Mounting method Reference, to Weight
programme be completed (1) kg
0 Front Multi-fixing KpC 007TL 0.121
8
L1 240 270 0 90 120
1
2 270 90
By Ø 22 mm KpC 007T 0.105
3
240 120
hole
4
Kpp 0pppX 1 5
6
2
3 Rear KpC 507T 0.140
4
5
6
K1 K2
9 K2 K1
K1 K2
N
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 001U.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
10 Example K2B 001U.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
3/40
References (continued) 3
Cam switches 3
Adaptable sub-assemblies, 12 A
Bodies (contact blocks + fixing plate)
To combine with operating heads: see pages 3/66
and 3/67
+
programme
1 decimal
(1) kg
1
Contact
marking 0 Front Multi-fixing K1A 001BL 0.101
87 65 43 21 45
Value 8 4 2 1 By Ø 22 mm K1A 001B 0.085
1 0 0 hole K1A 001BX (2) 0.163
2
3 1 45
4
5
6
2 90 Rear K1A 501B 0.125
Kpp 0pppL
7
8
3
4
135
180 2 decimal 2
5 225 0 Front Multi-fixing K1B 002BL 0.101
45
6 270
90
By Ø 22 mm K1B 002B 0.085
7 315 hole K1B 002BX (2) 0.163
3 decimal 3
0 Front Multi-fixing K1B 003BL 0.101
45
90
By Ø 22 mm K1B 003B 0.085
hole K1B 003BX (2) 0.163
135
4 decimal
0 Front Multi-fixing K1C 004BL 0.121
4
Kpp 0ppp 45
90 By Ø 22 mm K1C 004B 0.105
hole K1C 004BX (2) 0.183
135
180
5 decimal
0 Front Multi-fixing K1C 005BL 0.121
5
45
90 By Ø 22 mm K1C 005B 0.105
hole K1C 005BX (2) 0.183
225 135
180
6 decimal
0
45
Front Multi-fixing K1C 006BL 0.121
6
Kpp 5ppp
270 90 By Ø 22 mm K1C 006B 0.105
hole K1C 006BX (2) 0.183
225 135
180
7 decimal
315
0
45
Front Multi-fixing K1C 007BL 0.121 7
270 90
By Ø 22 mm K1C 007B 0.105
hole K1C 007BX (2) 0.183
225 135
180
8
8 decimal
+
Contact 0 30 Front Multi-fixing K1D 008BL 0.126
marking 87 65 43 21 60
By Ø 22 mm K1D 008B 0.110
8 4 2 1
Kpp 0pppX Value 90
hole
0 0 240 120 K1D 008BX (2) 0.188
1 210 180 150
2 1 30
3
4 2 60 Rear K1D 508B 0.150
5
6 3 90
7
9
8 4 120
5 150
6 180
7 210
8 240
(1) lth = 12 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/41
References (continued) 3
Cam switches 3
Adaptable sub-assemblies, 12 A
Bodies (contact blocks + fixing plate)
To combine with operating heads: see pages 3/66
and 3/67
9 decimal
+
Front Multi-fixing K1D 009BL 0.126
0 30
60
By Ø 22 mm hole K1D 009B 0.110
1
270 90 K1D 009BX (2) 0.188
240 120
2
3 210 180 150 Rear K1D 509B 0.150
2 Kpp 0pppL
4
5
6
7
10 decimal
8 Front Multi-fixing K1D 010BL 0.126
0 30
By Ø 22 mm hole K1D 010B 0.110
300 60
270 90
240 120
Contact 210 180 150 Rear K1D 510B 0.150
87 65 43 21 marking
3
8 4 2 1 Value 11 decimal
0 0
1 30
Front Multi-fixing K1D 011BL 0.126
330 0 30 By Ø 22 mm hole K1D 011B 0.110
2 60 300 60
3 90 270 90
240 120
4 120 210 180 150 Rear K1D 511B 0.150
5 150
6 180
4 7
8
210
240
Kpp 0ppp 9 270
10 300
11 330
6 2
3
4
5
Rear K1B 522B 0.125
7 87 65 43 21
8 4 2 1
Contact
marking
Value
4 decimal
1 0
Front Multi-fixing K1C 024BL 0.121
0
2 45 45 By Ø 22 mm hole K1C 024B 0.105
3 90 90 K1C 024BX (2) 0.183
4 135 135 Rear K1C 524B 0.140
5 180
8 6 225 5 decimal
Front Multi-fixing K1C 025BL 0.121
0
45 By Ø 22 mm hole K1C 025B 0.105
Kpp 0pppX
90 K1C 025BX (2) 0.183
180
135 Rear K1C 525B 0.140
6 decimal
9
Front Multi-fixing K1C 026BL 0.121
0
45 By Ø 22 mm hole K1C 026B 0.105
90 K1C 026BX (2) 0.183
225
180
135 Rear K1C 526B 0.140
(1) lth = 12 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/42
References (continued) 3
Cam switches 3
Adaptable sub-assemblies, 12 A
Bodies (contact blocks + fixing plate)
To combine with operating heads: see pages 3/66
and 3/67
2
2 180
3
Kpp 0pppL 4
5
6
7
8
8 decimal
Front Multi-fixing K1D 028BL 0.126
0
315 45 By Ø 22 mm hole K1D 028B 0.110
3
270 90
K1D 028BX (2) 0.188
Contact
225
180
135
Rear K1D 528B 0.150
87 65 43 21 marking
8 4 2 1 Value
1 0
2 30
3 60
9 decimal
4 90
Front Multi-fixing K1D 029BL 0.126
4
5 120 0 30
60 By Ø 22 mm hole K1D 029B 0.110
6 150 90
240 120 K1D 029BX (2) 0.188
Kpp 0ppp 7 180
210 180 150
8 210 Rear K1D 529B 0.150
9 240
10 270
11 300
12 330
10 decimal
0 30
Front Multi-fixing K1D 030BL 0.126 5
60 By Ø 22 mm hole K1D 030B 0.110
270 90 K1D 030BX (2) 0.188
240 120
210 180 150 Rear K1D 530B 0.150
11 decimal
6
Kpp 5ppp
Front Multi-fixing K1D 031BL 0.126
0 30
300 60 By Ø 22 mm hole K1D 031B 0.110
270 90 Rear K1D 531B 0.150
240 120
210 180 150
7
12 decimal
Front Multi-fixing K1D 032BL 0.126
330 0 30
300 60 By Ø 22 mm hole K1D 032B 0.110
270 90 Rear K1D 532B 0.150
8
240 120
210 180 150
Kpp 0pppX
(1) lth = 12 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
9
10
3/43
References (continued) 3
Cam switches 3
2 Kpp 0pppL
r1 r2
r1 r2 r3
5 8 8
r1 r2 r3 r4
6
L1 L2 0 45 90 By Ø 22 mm KpD 012G 0.110
1 1 0
2 2 45 hole KpD 012GX (2) 0.188
3 3 90
Kpp 5ppp 4 4 Rear KpD 512G 0.150
5 5
6 6
7 7
8 8
r1 r2
8
9
10 10
11 11
12 12
Kpp 0pppX
r1 r2 r3
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 002G.
9 To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2B 002G.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/44
References (continued) 3
Cam switches 3
2
7 7
8 8
Kpp 0pppL 9 9
10
10 11
11 12
12 13
13 14
14 15
15 16
16
r1 r2 r3 r4
4
10 11
11 12
12
Kpp 0ppp
r1 r2
5
3 2
4 3 90 hole KpI 023GX (2) 0.263
5 4
6 5
6
135 Rear KpI 523G 0.215
7
8 7
9 8
9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
6
17 17
18 18
Kpp 5ppp r1 r2 r3
8
19 19
20 20
21 21
22 22
23 23
24
Kpp 0pppX 24
r1 r2 r3 r4
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1H 014G.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2H 014G.
9
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/45
References (continued) 3
Cam switches 3
2 step + “0”
Front Multi-fixing KpB 002QL 0.101
L1
0
45 By Ø 22 mm hole KpB 002Q 0.085
1 90 KpB 002QX (2) 0.163
2
3 Rear KpB 502Q 0.125
2 2 4
Kpp 0pppL 5
3 6
7
4 8
9 3 step + “0”
5 10
Front Multi-fixing KpC 003QL 0.121
11 0
6 12 45 By Ø 22 mm hole KpC 003Q 0.105
3
13
14
90 KpC 003QX (2) 0.183
7 135
1 2 3 4 5 6 7
Rear KpC 503Q 0.140
4 step + “0”
0 45 90 135 180 225 270 315 Front Multi-fixing KpD 004QL 0.126
4 2
1
2
3
4
0
45
90
By Ø 22 mm hole KpD 004Q
KpD 004QX (2)
0.110
0.188
Kpp 0ppp 5
3 6 180
135
Rear KpD 504Q 0.150
7
4 8
9
5 10
11
6 12
13
7 14
5 5 step + “0”
Front Multi-fixing KpE 005QL 0.146
0
45 By Ø 22 mm hole KpE 005Q 0.130
90 KpE 005QX (2) 0.208
225
180
135 Rear KpE 505Q 0.165
6 6 step + “0”
Kpp 5ppp
Front Multi-fixing KpF 006QL 0.156
0
45 By Ø 22 mm hole KpF 006Q 0.140
270 90 KpF 006QX (2) 0.218
225 135 Rear KpF 506Q 0.175
180
7
7 step + “0”
Front Multi-fixing KpG 007QL 0.176
0
315 45 By Ø 22 mm hole KpG 007Q 0.160
270 90 KpG 007QX (2) 0.238
8 225
180
135 Rear KpG 507Q 0.190
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 002Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
9 Example K2B 002Q.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/46
References (continued) 3
Cam switches 3
Kpp 0pppL 3
5
6
7
2
4 8
9
10
5 9 step + “0”
11
6 12 Front Multi-fixing KpI 009QL 0.201
0 30
13 By Ø 22 mm KpI 009Q 0.185
14 60
7 hole
3
270 90 KpI 009QX (2) 0.263
15 240 120
8 16
210 180 150 Rear KpI 509Q 0.215
17
9 18
Kpp 0ppp 19
10 20
21
22
11
1 2 3 4 5 6 7 8 9 10 11 10 step + “0”
Front Multi-fixing KpK 010QL 0.211
300
270
0 30
60
90
By Ø 22 mm
hole
KpK 010Q
KpK 010QX (2)
0.195
0.273
4
0 30 60 90 120 150 180 210 240 270 300 330 240 120
1 210 180 150 Rear KpK 510Q 0.220
2
3
2 4
5
3 6
Kpp 5ppp 7
4 8
9
5
5 10
11 11 step + “0”
6 12
13 Front Multi-fixing KpL 011QL 0.231
7 14
15 330 0 30 By Ø 22 mm KpL 011Q 0.215
8 16 300 60
17 270 90 hole KpL 011QX (2) 0.293
9 18 240 120
10
19
20 210 180 150 Rear KpL 511Q 0.240
21
11 22
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
6
Example K1H 008Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2H 008Q.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/47
References (continued) 3
Cam switches 3
2 step
L1 Front Multi-fixing KpB 002NL 0.101
0
45 By Ø 22 mm hole KpB 002N 0.085
1
2
KpB 002NX (2) 0.163
3
4 Rear KpB 502N 0.125
2
2
5
Kpp 0pppL 3 6
7
4 8 3 step
9 Front Multi-fixing KpC 003NL 0.121
5 10
0
45 By Ø 22 mm hole KpC 003N 0.105
11
6 12
90 KpC 003NX (2) 0.183
13
Rear KpC 503N 0.140
3
7 14
15
8 16
1 2 3 4 5 6 7 8 4 step
Front Multi-fixing KpD 004NL 0.126
0
45 By Ø 22 mm hole KpD 004N 0.110
90 KpD 004NX (2) 0.188
135 Rear KpD 504N 0.150
4 Kpp 0ppp
0 45 90 135 180 225 270 315
1
2
3
2 4
5 5 step
3 6
4
7
8
Front Multi-fixing KpE 005NL 0.146
5
9
10
0
45 By Ø 22 mm hole KpE 005N 0.130
6
11
12 90 KpE 005NX (2) 0.208
13
Rear KpE 505N 0.165
5
7 14 135
15 180
8 16
6 step
Front Multi-fixing KpF 006NL 0.156
0
45 By Ø 22 mm hole KpF 006N 0.140
90 KpF 006NX (2) 0.218
6
225 135
180 Rear KpF 506N 0.175
Kpp 5ppp
7 step
Front Multi-fixing KpG 007NL 0.176
0
45 By Ø 22 mm hole KpG 007N 0.160
270 90 KpG 007NX (2) 0.238
7 225
180
135 Rear KpG 507N 0.190
8 step
Front Multi-fixing KpH 008NL 0.181
315
0
45 By Ø 22 mm hole KpH 008N 0.165
270 90 KpH 008NX (2) 0.243
8 Kpp 0pppX
225
180
135 Rear KpH 508N 0.195
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1B 002N.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2B 002N.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
9 KAX Z1ppp.
10
3/48
References (continued) 3
Cam switches 3
2
5
6 Rear KpI 509N 0.215
3
Kpp 0pppL 7
4 8
9
5 10
11
6 12
13 10 step
7 14
Front Multi-fixing KpK 010NL 0.211
3
15 0 30
8 16 60 By Ø 22 mm KpK 010N 0.195
17 270 90 hole KpK 010NX (2) 0.273
9 18 240 120
210 180 150
19
10 20 Rear KpK 510N 0.220
21
Kpp 0ppp 11 22
23
12 24
4
1 2 3 4 5 6 7 8 9 10 11 12
11 step
Front Multi-fixing KpL 011NL 0.231
0 30
300 60
By Ø 22 mm KpL 011N 0.215
0 30 60 90 120 150 180 210 240 270 300 330 270 90 hole KpL 011NX (2) 0.293
1 240 120
2 210 180 150
3 Rear KpL 511N 0.240
2 4
5
5
3 6
7
4 8
9
Kpp 5ppp 5 10
11
6 12
13
7 14
15 12 step
8 16
17 Front Multi-fixing KpM 021NL 0.241
9 18 330 0 30
19 By Ø 22 mm KpM 021N 0.225
6
10 20 300 60
21 270 90 hole KpM 021NX (2) 0.303
11 22 240 120
23 210 180 150
12 24
Rear KpM 521N 0.245
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1I 009N.
7
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2I 009N.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/49
References (continued) 3
Cam switches 3
2 step + “0”
L1 L2 Front Multi-fixing KpD 012QL 0.126
0
1 45 By Ø 22 mm hole KpD 012Q 0.110
2
3 90 KpD 012QX (2) 0.188
4
5 Rear KpD 512Q 0.150
2
6
7
Kpp 0pppL 2 8
9
10
11
3 12
13
14
15
4 16
17
18 3 step + “0”
19
5 20
21
Front Multi-fixing KpF 013QL 0.156
3 22 0
23 45 By Ø 22 mm hole KpF 013Q 0.140
6
90 KpF 013QX (2) 0.218
1 2 3 4 5 6
135 Rear KpF 513Q 0.175
0 45 90 135 180 225 270
1
2
3
4
5
6
4 2
7
8
9
10 4 step + “0”
Kpp 0ppp 11
3 12 Front Multi-fixing KpH 014QL 0.181
13 0
14 45 By Ø 22 mm hole KpH 014Q 0.165
15
4 16 90 KpH 014QX (2) 0.243
17
18 135 Rear KpH 514Q 0.195
19 180
5 20
5
21
22
23
6 24
5 step + “0”
Front Multi-fixing KpK 015QL 0.211
0
45 By Ø 22 mm hole KpK 015Q 0.195
6 225
90
135 Rear
KpK 015QX
KpK 515Q
(2) 0.273
0.220
180
Kpp 5ppp
7 6 step + “0”
Front Multi-fixing KpM 016QL 0.241
0
45 By Ø 22 mm hole KpM 016Q 0.225
270 90 KpM 016QX (2) 0.303
225 135
180 Rear KpM 516Q 0.245
8
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1D 012Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2D 012Q.
9
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/50
References (continued) 3
Cam switches 3
2
5
6
Kpp 0pppL 2
7
8
9
10
11
3 12
13
14
15
4 16
17 3 step
18
19 Front Multi-fixing KpF 013NL 0.156
3
5 20 0
21 45 By Ø 22 mm hole KpF 013N 0.140
22
23 90 KpF 013NX (2) 0.218
6
1 2 3 4 5 6
Rear KpF 513N 0.175
4
5
6
7
2 8 4 step
Kpp 0ppp 9
10
11
Front Multi-fixing KpH 014NL 0.181
3 0
12 45 By Ø 22 mm hole KpH 014N 0.165
13
14 90
15 KpH 014NX (2) 0.243
4 16 135 Rear KpH 514N 0.195
17
18
19
5
5 20
21
22
23
6 24
5 step
Front Multi-fixing KpK 015NL 0.211
0
45 By Ø 22 mm hole KpK 015N 0.195
180
90
135 Rear
KpK 015NX
KpK 515N
(2) 0.273
0.220
6
Kpp 5ppp
6 step
Front Multi-fixing KpM 016NL 0.241
7
0
45 By Ø 22 mm hole KpM 016N 0.225
90 KpM 016NX (2) 0.303
225
180
135 Rear KpM 516N 0.245
8
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1D 012N.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2D 012N.
9
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/51
References (continued) 3
Cam switches 3
L1 L2 L3 0 45 90 2 step + “0”
1 1
2 2
3
Front Multi-fixing KpF 022QL 0.156
3
4 0
4
5 5 45 By Ø 22 mm KpF 022Q 0.140
6
6
7 7
90
hole KpF 022QX (2) 0.218
8
8 9
9 10
2
10
11
11
12
Rear KpF 522Q 0.175
12
Kpp 0pppL 1 2
L1 L2 L3
0 45 90 135 3 step + “0”
1
1
2
2
3 Front Multi-fixing KpI 023QL 0.201
3 4 0
4 5 45 By Ø 22 mm KpI 023Q 0.185
5 6
6 7 90 hole KpI 023QX (2) 0.263
7 8
8 9
9 10 135
L1 L2 L3
0 45 90 135 180 4 step + “0”
1
1
2
3 2 Front Multi-fixing KpM 024QL 0.241
3 0
4
4
5
6
4
5
45 By Ø 22 mm KpM 024Q 0.225
7
8
6
7 90 hole KpM 024QX (2) 0.303
9 8
Kpp 0ppp 10
11
9
10 180
135
12
13
11
12
Rear KpM 524Q 0.245
14 13
15 14
16 15
17 16
18 17
19 18
20 19
21 20
5
22 21
23 22
24 23
1 2 3 4 24
6
11 180
12 11
12
Rear KpP 525Q 0.285
13
14 13
15 14
15
Kpp 5ppp 16
17 16
18 17
19 18
20 19
21 20
22 21
23 22
24 23
25 24
26 25
27 26
28 27
7 29 28
30 29
30
1 2 3 4 5
8
12 12
13 13
14 14
15 15
16 16
17 17
18
Kpp 0pppX 19
18
19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
9
30 30
31 31
32 32
33 33
34 34
35 35
36 36
1 2 3 4 5 6
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1F 022Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2F 022Q.
10 (2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
3/52
References (continued) 3
Cam switches 3
2
10 10
11 11
12
Kpp 0pppL 12
1 2
L1 L2 L3 0 45 90 3 step
1 1
2 2 Front Multi-fixing KpI 023NL 0.201
3 3 0
4
5
4
5
45 By Ø 22 mm KpI 023N 0.185
6
7
6
7 90 hole KpI 023NX (2) 0.263
8 8
9 9 Rear KpI 523N 0.215
3
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18
18
1 2 3
L1 L2 L3 0 45 90 135 4 step
1 1
2
3
2
3 Front Multi-fixing KpM 024NL 0.241
4 4 0
4
5 5 45 By Ø 22 mm KpM 024N 0.225
6 6
7
8
7 90 hole KpM 024NX (2) 0.303
8
9 9
Kpp 0ppp 10
11
10
135
Rear KpM 524N 0.245
11
12 12
13 13
14 14
15 15
16 16
17
18 17
19 18
20 19
21 20
21
5
22
23 22
24 23
24
1 2 3 4
6
11 180
11
12 12
13 13
14 14
15 15
Kpp 5ppp 16
17
16
18 17
19 18
20 19
21 20
22 21
23 22
24 23
25 24
26 25
27 26
27
7
28
29 28
30 29
30
1 2 3 4 5
8
12 11
13 12
14 13
15 14
16 15
17 16
18 17
Kpp 0pppX 19 18
20 19
21 20
22 21
23 22
24 23
25 24
26 25
27 26
28 27
29 28
9
30 29
31 30
32 31
33 32
34 33
35 34
36
35
1 2 3 4 5 6 36
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1F 022N.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2F 022N.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp. 10
3/53
References (continued) 3
Cam switches 3
L1 L2 L3 L4 2 step + “0”
0 45 90
1 1
2
Front Multi-fixing KpH 032QL 0.181
2 0
3
3
4 4 45 By Ø 22 mm KpH 032Q 0.165
5
5
6 6 90 hole KpH 032QX (2) 0.200
7 7
8
8 9 Rear KpH 532Q 0.195
2
9 10
10 11
11
Kpp 0pppL 12
12
13
13 14
14 15
15 16
16
1 2
4 21 22
22 23
23 24
24
Kpp 0ppp 1 2 3
6
24 26
25 27
26 28
27 29
28 30
Kpp 5ppp 29
30
31
32
31
32
1 2 3 4
7
3 0
2 4 45
3 5 By Ø 22 mm KpU 035Q 0.335
4 6
5 7
90 hole
6 8
7
8
9
10
225
180
135 Rear KpU 535Q 0.345
9 11
10 12
11 13
12 14
13 15
14 16
15 17
16 18
17 19
18
8
20
19 21
20 22
21 23
22 24
23 25
24 26
Kpp 0pppX 25 27
26 28
27 29
28 30
29 31
30 32
31 33
32 34
33 35
34 36
37
9
35
36 38
37 39
40
38
39
40
1 2 3 4 5
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1H 032Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2H 032Q.
10 (2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
3/54
References (continued) 3
Cam switches 3
2
9 11
10 12
11 13
Kpp 0pppL 12 14
13 15
14 16
15
16
1 2
L1 L2 L3 L4 0 45 90 3 step
1
1
2
3
Front Multi-fixing KpM 033NL 0.241
2 4 0
3 45 By Ø 22 mm KpM 033N 0.225
3
5
4 6
5
6
7 90 hole
8
7
8
9
10
Rear KpM 533N 0.245
9 11
10 12
11 13
12 14
13 15
14 16
15 17
16 18
17 19
18 20
19 21
22
4
20
21 23
22 24
23
24
Kpp 0ppp 1 2 3
L1 L2 L3 L4 0 45 90 135 4 step
1
1 2 Front Multi-fixing KpQ 034NL 0.296
2 3 0
3 4
5
45 By Ø 22 mm KpQ 034N 0.280
4
5 6
7 90 hole
6
8
Rear KpQ 534N 0.295
5
7
8 9 135
9 10
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
19 20
20 21
21 22
22 23
23 24
25
6
24 26
25 27
26 28
27 29
28 30
Kpp 5ppp 29
30
31
32
31
32
1 2 3 4
7
2 3 0
3 4
5
45 By Ø 22 mm KpU 035N 0.335
4
5 6
7 90 hole
6
8
7
8 9 135 Rear KpU 535N 0.345
9 10 180
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
8
19 20
20 21
21 22
22 23
23 24
24 25
26
Kpp 0pppX 25
26 27
27 28
28 29
29 30
30 31
31 32
32 33
33 34
34 35
35 36
9
36 37
37 38
38 39
40
39
40
1 2 3 4 5
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1H 032N.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2H 032N.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp. 10
3/55
References (continued) 3
Cam switches 3
For 3 circuits
K L 0 90 180 270 Front Multi-fixing K1F 003ML 0.156
L1 1 0
L2
K I K L
2 By Ø 22 mm K1F 003M 0.140
K I K L
L3
K I
3
4 270 90 hole K1F 003MX (2) 0.218
5
1 6 Rear K1F 503M 0.175
2
2 180
7
3 8
Kpp 0pppL 4 9
5 10
6 11
7 12
8
9
10
11 A
12
For 4 circuits
Front Multi-fixing K1H 004ML 0.181
3 L1
L2
K
K
L
I K
K
L
0 60 120 180 240
1
2
0
60
By Ø 22 mm K1H 004M
hole
0.165
L3
I K L 3
4
K1H 004MX (2) 0.243
K I K L 240 120
L4 5
K I
6 180
Rear K1H 504M 0.195
1 7
2 8
3 9
4 10
5 11
6 12
7 13
4 8 14
9 15
10 16
11
K1p 0ppp 12
13
14
15 A
16
For 3 circuits
K L 0 90 180 Front Multi-fixing K1F 013ML 0.156
L1 1
K I K L 0
L2
K I K
2 By Ø 22 mm K1F 013M 0.140
L 3
L3
K I 4 90 hole K1F 013MX (2) 0.218
5
1 6 Rear K1F 513M 0.175
6
2 7 180
3 8
4 9
5 10
6 11
K1p 5ppp 7 12
8
9
10
11 A
12
For 4 circuits
8 8 14
9 15
10 16
11
12
K1p 0pppX 13
14
15 A
16
(1) Ith = 12 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
9
KAX Z1ppp.
10
3/56
References (continued) 3
Cam switches 3
Voltmeter switches
Wiring diagram Switching Switch position Mounting method Reference Weight
programme (1) kg
1
For measurements between 3 phases and neutral
With “0” position
0 45 90 135 Front Multi-fixing K1D 023ML 0.126
L1 2 3 N 1 0
2 45 By Ø 22 mm K1D 023M 0.110
1
2
3
90 hole K1D 023MX (2) 0.188
4
2
3 5
4 6 135 Rear K1D 523M 0.150
K1p 0pppL 5 7
6 8
7
8
V
3
1
2 45 By Ø 22 mm K1D 033M 0.110
3
4
90 hole
5
6
Rear K1D 533M 0.150
7
8
6
7
8
K1p 5ppp
(1) Ith = 12 A. 9
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/57
References (continued) 3
Cam switches 3
2
3
6
4
5 7 225 135 Rear K1H 526M 0.195
K1p 0pppL 6 8
7 9
8 10
9 11
10 12
11 13
12 14
13 15
14 16
15
16
V Without “0” position
4
14
15
16
K1p 0ppp
For measurements between 3 phases and between each of the 3 phases and neutral
With “0” position
L1 2 3 N 225 270 315 0 45 90 135 Front Multi-fixing K1F 027ML 0.156
1 0
1 2 315 45 By Ø 22 mm K1F 027M 0.140
2 3
hole K1F 027MX (2) 0.218
5
3 4 270 90
4 5
5
6
6
7
225 135 Rear K1F 527M 0.175
7 8
8 9
9 10
10 11
11 12
12
V
7
(1) Ith = 12 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
8
K1p 0pppX
10
3/58
References (continued) 3
Cam switches 3
2
1
1
2
L1 L2 315 0 45 90
1
2
2-pole: 2 step to right + 1 step to left
Front Multi-fixing KpF 012LL 0.156
3
3
4 3
0
5
6
4
5 315 45 By Ø 22 mm KpF 012L 0.140
7
8
6
90 hole KpF 012LX (2) 0.218
9 7
8
10
11 9 Rear KpF 512L 0.175
12 10
13
14 11
15 12
4
16
A123 A123
1 2
5
10 11
11 12
12 13
13 14
14 15
15 16
16
A123 A123
1 2
L1 L2 L3 315 0 45 90 3-pole: 2 step to right + 1 step to left
1 1
2 2 Front Multi-fixing KpI 022LL 0.201
3 3
6
0
4 4 315 45 By Ø 22 mm KpI 022L 0.185
5 5
6 6 90 hole
7 7
Kpp 5ppp 8 8 Rear KpI 522L 0.210
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18
7
18
A12 A12 A12
1 2 3
L1 L2 L3 315 0 45 90 135 3-pole: 3 step to right + 1 step to left
1 1
2 2 Front Multi-fixing KpM 023LL 0.241
3 3
4 4
5 315
0
45 By Ø 22 mm KpM 023L 0.225
5
6 6
90 hole
7 7
8 8
9 135
Rear KpM 523L 0.245
9 10
10
8
11 11
12
12 13
13 14
14 15
15 16
Kpp 0pppX 16 17
17 18
18 19
19 20
20 21
21 22
22 23
23 24
24
9
A123 A123 A123
1 2 3
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1C 022Q.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2C 022Q.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/59
References (continued) 3
Cam switches 3
Multi-circuit switches
Wiring diagram Switching Switch Mounting method Reference, to Weight
1 programme position be completed
(1)
kg
1-pole
1L1 2L1 0 45 90 135 Front Multi-fixing KpB 001SL 0.101
1 0
1 2 45 By Ø 22 mm KpB 001S 0.085
2 3
3 4 90 hole KpB 001SX (2) 0.163
4
1.1 2.1 135 Rear KpB 501S 0.125
2 Kpp 0pppL
2-pole
1
L1 L2
2
L1 L2
0 45 90 135 Front Multi-fixing KpD 002SL 0.126
1 0
1 2 45 By Ø 22 mm KpD 002S 0.110
3
2
4 90 hole KpD 002SX (2) 0.188
3
4 5
5 6 135 Rear KpD 502S 0.150
6 7
8
7
3 8
1.1 1.2 2.1 2.2
3-pole
1
L1 L2 L3
2
L1 L2 L3 0 45 90 135 Front Multi-fixing KpF 003SL 0.156
1 0
1 2 45 By Ø 22 mm KpF 003S 0.140
2 3
3 4 90 hole KpF 003SX (2) 0.218
4 5
5
6
6 135 Rear KpF 503S 0.175
4
7
7 8
8 9
9 10
10 11
Kpp 0ppp 11 12
12
1.1 1.2 1.3 2.1 2.2 2.3
4-pole
1
L1 L2 L3 L4
2
L1 L2 L3 L4
0 45 90 135
1
Front Multi-fixing KpH 004SL 0.181
0
1 2
3
45 By Ø 22 mm KpH 004S 0.165
5
2
3 4 90 hole
4 5
5 6
7
135 Rear KpH 504S 0.195
6
7 8
9
8 10
9 11
10 12
11 13
12 14
13 15
14 16
15
16
6 5-pole
1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4
Kpp 5ppp 1
L1 L2 L3 L4 L5
2
L1 L2 L3 L4 L5 0 45 90 135 Front Multi-fixing KpK 005SL 0.211
1 0
1 2 45 By Ø 22 mm KpK 005S 0.195
2
3
3
4 90 hole
4
5
5
6 135 Rear KpK 505S 0.220
6 7
7
7
8
8 9
9 10
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
19 20
20
1.1 1.2 1.3 1.4 1.5 2.1 2.2 2.3 2.4 2.5
8 (1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1F 003S.
Kpp 0pppX To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2F 003S.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/60
References (continued) 3
Cam switches 3
2
6 7
7 8
Kpp 0pppL 8
UV
3-pole
3
L1 L2 L3 315 0 45 Front Multi-fixing KpE 003WL 0.146
1 0
1 2 315 45 By Ø 22 mm KpE 003W 0.130
2
3
3
4
hole KpE 003WX (2) 0.208
4 5
5 6 Rear KpE 503W 0.165
6 7
7 8
4
8 9
9 10
10
Kpp 0ppp UVW
Reversing switches with spring return from 330° and from 30° to “0” position
Wiring diagram Switching Switch position Mounting method Reference, to Weight
5
programme be completed kg
(1)
2-pole
330 0 30 Front Multi-fixing KpD 022WL 0.126
L1 L2
1
By Ø 22 mm KpD 022W 0.110
6
1 2 330 0 30
2 3 hole KpD 022WX (2) 0.188
3 4
4 5
Kpp 5ppp 5 6 Rear KpD 522W 0.150
6 7
7 8
8
UV
7
3-pole
L1 L2 L3
Front Multi-fixing KpE 023WL 0.146
330 0 30
1 By Ø 22 mm KpE 023W 0.130
1 2 330 0 30
2 hole KpE 023WX (2) 0.208
8
3
3 4
4
5
5
6 Rear KpE 523W 0.165
6 7
7 8
Kpp 0pppX 8 9
9 10
10
UVW
9
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1D 002W.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2D 002W.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/61
References (continued) 3
Cam switches 3
Adaptable sub-assemblies, 12 A
Bodies (contact blocks + fixing plate)
To combine with operating heads: see pages 3/66
and 3/67
Star-delta switches
Wiring diagram Switching Switch position Mounting method Reference Weight
1 L1 L2 L3
programme
0 60 120 Front Multi-fixing
(1)
K2H 001YL
kg
0.181
1 0
2 By Ø 22 mm K2H 001Y 0.165
1 3 60
2 4 hole K2H 001YX (2) 0.243
3 5
120
4
5
6
7 Rear K2H 501Y 0.195
6 8
7 9
8 10
9 11
2
10 12
11 13
K2p 0pppL 12 14
15
13
14 16
15
16
W2 U1
W1 U2
V2 V1
4
10
11 13
12 14
13 15
14 16
K2p 0ppp 15
16
W2 U1
W1 U2
V2 V1
5
With slave contact, with supply disconnection
L N L1 L2 L3 0 60 120 Front Multi-fixing K2K 004YL 0.211
1
b 0
a
2 By Ø 22 mm K2K 004Y 0.195
1 3 60
2 4 hole K2K 004YX (2) 0.273
3 5
6 120
4
5 7 Rear K2K 504Y 0.220
6 8
7 9
8 10
9 11
10 12
6 11 13
12 14
13 15
14 16
17
K2p 5ppp 15
16 18
17
19
20
18
19 W2 U1
20
W1 U2
V2 V1
8
3 5
4
5
6
7
240 120 Rear K2K 506Y 0.220
6 8
7 9
8 10
K2p 0pppX 9 11
12
10
11 13
12 14
13 15
14 16
15 17
16 18
17 19
20
9
18
19 W2 U1
20
W1 U2
V2 V1
(1) lth = 20 A.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/62
References (continued) 3
Cam switches 3
2
8 10
9 11
Kpp 0pppL 10 12
11 13
12 14
13 15
14 16
15 17
16 18
17 19
18 20
21
19 W2 U1
22
20 23
21 W1 U2 24
22
3
23 V2 V1
24
1U 2U
5
1W 1V 2W 2V
1U 2U
7
1W 1V 2W 2V
8
7 9
8 10
9 11
10 12
11 13
12 14
Kpp 0pppX 13 15
14 16
15
16
1U
2U 2W
1W 2V 1V
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
9
Example K1F 001P.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2F 001P.
(2) lth = 20 A.
(3) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/63
References (continued) 3
Cam switches 3
For motors with tapped “Dahlander” windings, with centre “0” position
L1 L2 L3 300 0 60 Front Multi-fixing KpH 005PL 0.181
1
0
2
3
By Ø 22 mm KpH 005P 0.165
1 300 60
2 4
5
hole KpH 005PX (2) 0.243
3
4 6
5 7 Rear KpH 505P 0.195
2
6 8
7 9
Kpp 0pppL 8
9
10
11
10 12
11
13
14
12 15
13 16
14
15
16
1U
2U 2W
3
1W 2V 1V
Kpp 0ppp
L1 L2 L3 240 300 0 60 120 Front Multi-fixing KpK 008PL 0.211
1
0
1
2
3 300 60
By Ø 22 mm KpK 008P 0.195
2
3
4 hole
5
240 120
4
5
6
7
Rear KpK 508P 0.220
6 8
7 9
5
8 10
9 11
10
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
19 20
1U 2U
20
1W 1V 2W 2V
6
Kpp 5ppp
For motors with tapped “Dahlander” windings, with centre “0” position
L1 L2 L3 240 300 0 60 120 Front Multi-fixing KpM 009PL 0.241
1 0
1
2
300 60
By Ø 22 mm KpM 009P 0.225
3
2 4 hole
7
3 5 240 120
4
5 6 Rear KpM 509P 0.245
6 7
7 8
8 9
9 10
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17 18
18 19
19 20
8
1U
20 21
2U 2W
21 22
22 2V 23
23 24
1W 1V
24
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1H 005P.
9
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
Example K2H 005P.
(2) Bodies using the Ø 22 mm hole mounting method that can be fitted with chromium plated metal bezel operating heads, type
KAX Z1ppp.
10
3/64
References (continued) 3
Cam switches 3
Kpp 0pppL
6
7
8
9
8
9
10
11
12
2
10
11 13
12 14
15
13 16
14 17
15 18
16 19
17 20
18 21
19 1U 2W2 2U1
22
3
20
21 3U 3W
3V
22
1W 1V 2W1 2V1
For motors with open tapped “Dahlander” winding and separate winding for intermediate speed
L1 L2 L3 0 60 120 180 Front Multi-fixing KpL 011PL 0.231
1
0
2 By Ø 22 mm KpL 011P 0.215
3 60
4
1
2 4
5
hole
3
120
4
5
6
7 Rear KpL 511P 0.240
180
Kpp 0ppp 6
7
8
9
8 10
9 11
10 12
11 13
12 14
13 15
14 16
15 17
16 18
5
17 19
18 20
21
19 22
20 2U 1W2 1U1
21 3U 3W
22 3V
2W 2V 1W1 1V1
6
Kpp 5ppp For motors with open tapped “Dahlander” winding and separate winding for high speed
L1 L2 L3 0 60 120 180 Front Multi-fixing KpL 012PL 0.231
1 0
2
60
By Ø 22 mm KpL 012P 0.215
1 3
2 4 hole
3 5
120
4
5
6
7
Rear KpL 512P 0.240
180
7
6 8
7 9
8 10
9 11
10 12
11 13
12 14
13 15
14 16
15 17
16 18
17 19
18 20
19 21
20
1W2 1U1 3U
22
8
21
2U 2V
22 2W
1W1 1V1 3W 3V
Kpp 0pppX
(1) To order a cam switch with thermal current Ith = 12 A, replace the p in the reference by 1.
Example K1L 010P.
To order a cam switch with thermal current Ith = 20 A, replace the p in the reference by 2.
9
Example K2L 010P.
10
3/65
References 3
Cam switches 3
4
0
1 L = 35 mm Metallic Without KBC 1H41 0.012
KAC 1H
45° 0 Black handle Matt black Without KAC 1H48 0.012
2 1 L = 35 mm Metallic Without KBC 1H48 0.012
6 Red handle
L = 35 mm
– Without KDC 1LH 0.046
9
(1) For separate marked legend ordering information, see pages 3/68 to 3/71.
(2) Head supplied with “Ronis” 8R1 key. To order a head with a “Ronis” 455 key, add the suffix R to the references listed above.
KBD 1H Example: reference for Ø 22 mm hole, front mounting 45 x 45 mm operating head with 45° switching angle and matt black
legend, becomes KAC 1SR. For a head with “Ronis” 8R15 key, use the suffix R1.
10
3/66
References (continued) 3
Cam switches 3
KBD 1p
Without legend
(2)
45° and 90°
60°
Key (1)
Key (1)
–
–
Without
Without
KDD 1S
KDD 1Z
0.066
0.066
2
With Ø 29 mm, metallic finish, plastic bezel and handle or key operator (1)
Description Switching Type of Colour of Padlocking Reference Weight
angle and operator bezel device kg
marking
Circular heads – Black handle Matt black Without KAA 1H 0.042
45°
L = 35 mm
Key (1)
Metallic
Matt black
Without
Without
KBA 1H
KAA 1S
0.042
0.057
3
Metallic Without KBA 1S 0.057
60° Key (1) Matt black Without KAA 1Z 0.057
Metallic Without KBA 1Z 0.057
With Ø 38 mm, black, plastic bezel and handle
KBA 1H Circular head – Black handle Matt black Without KAA 2H 0.048
L = 35 mm
With Ø 28.5 mm chromium plated, metal bezel (3) (2) and standard, handle, long handle or key operator (4)
4
Circular heads – Standard black Metal Without KAX Z1M12 0.040
handle
Standard red Metal Without KAX Z1M14 0.040
handle
Long black Metal Without KAX Z1C12 0.040
handle
Long red Metal Without KAX Z1C14 0.040 5
handle
30° Key Metal Without KAX Z1S13p (4) 0.065
KBA 1p
45° Key Metal Without KAX Z1S14p (4) 0.065
60° Key Metal Without KAX Z1S16p (4) 0.065
90° Key Metal Without KAX Z1S19p (4) 0.065
Operating heads for 4 hole, rear mounting bodies
Description Switching Type of Background Padlocking Reference Weight
6
angle and operator colour of device kg
marking legend
With 45 x 45 mm front plate and handle
With blank legend – Black handle Matt black Without KAE 1H 0.029
(to be engraved by user) L = 35 mm Metallic Without KBE 1H 0.029
KAX Z1C12
With marked legend 90° O
I
Red handle
L = 35 mm
Yellow Without
With
KCE 1LH
KCE 1Y
0.029
0.060
7
Without legend – Black handle – Without KDE 1H 0.027
(2) L = 35 mm
Red handle – Without KDE 1LH 0.027
L = 35 mm
With 60 x 60 mm front plate and handle
With blank legend – Black handle Matt black Without KAF 1H 0.068
8
(to be engraved by user) L = 42 mm Metallic Without KBF 1H 0.068
With marked legend 90° O Red handle Yellow Without KCF 1MH 0.068
I
L = 42 mm
KBE 1H
Without legend – Black handle Without KDF 1H 0.066
(2) L = 42 mm
(1) Head supplied with “Ronis” 8R1 key. To order a head with a “Ronis” 455 key, add the suffix R to the references listed above.
9
Example: reference for operating head with 60 x 60 mm front plate, key operator, blank legend, 45° switching angle and matt
black background, becomes KAD 1SR. For a head with “Ronis” 8R15 key, use the suffix R1.
(2) For separate marked legend ordering information, see pages 3/68 to 3/71.
(3) Heads only for use with bodies Kpp ppppX, incorporating adaptor plate KZ 127. See pages 3/34 to 3/64.
(4) To order:
- a head with key n° 455, replace the p in the reference by 1. Example: KAX Z1S131,
- a head with key n° 421, replace the p in the reference by 2. Example: KAX Z1S132,
- a head with key n° 520, replace the p in the reference by 3. Example: KAX Z1S133, 10
- a head with a special key, replace the p in the reference by 9. Example: KAX Z1S139 (state the key number on the order).
Key withdrawal from all positions.
3/67
References 3
Cam switches 3
2 45°
KZ 18041L KZ 18042L KZ 18043L KZ 18044L KZ 18045L KZ 18046L KZ 18047L KZ 18048L KZ 18412L KZ 18413L
0 0 0 0 0 0 0 0
L1-L2 0 L1-L2
1 1 1 1 1 1 7 1 2 1 0 L1-N
KZ 18415L KZ 18416L KZ 18417L KZ 18418L KZ 18419L KZ 18420L KZ 18421L KZ 18422FL KZ 18423FL KZ 18434L
3 1 2 1 2
3
1 2
3
1 2
3
1 2
3 7
1 2
3
8
7
1 2
3
ARRET
MAR-
CHE
MAIN
AUTO
0
HAND AUTO
4 5 4 6 4 6 4 6 4
5 5 5
KZ 18436FL KZ 18451L
ARRET 1 0 2
GAUCHE DROITE
4
60°
KZ 18061L KZ 18630L KZ 18631L KZ 18632L KZ 18634L KZ 18635L KZ 18637L KZ 18068L
0 0 0 0 0 0
1 2 STOP START
1 2 1 1 1 1
5 2
3
2 2 2
90°
KZ 18091L KZ 18093L KZ 18913L KZ 18931FL
0 0 0 ARRET
1 1 MAR-
1
6
3
2 CHE
2
7
90°
KZ 19093L KZ 19098FL KZ 19910L
0
ARRET MAR-
8
STOP START
1 CHE
45 x 45 mm legends - unmarked
Colour Sold in Unit reference Weight
lots of kg
9 Black
Metallic
20
20
KZ 17L
KZ 18L
0.003
0.003
Yellow 10 KZ 19L 0.003
(1) Weight = 0.003 kg.
10
3/68
References 3
Cam switches 3
45°
KZ 18041 KZ 18042 KZ 18043 KZ 18044 KZ 18045 KZ 18046 KZ 18047 KZ 18048 KZ 18412 KZ 18413
2
0 0 0 1 0 1 0 0 0
0 1 1 1 1 7 1 L1-L2 0 L1-L2 0 L1-N
2 1
2 2 2 2 6 2 6 2 L2- L2- L2-
L3 L3 N
3 4 3 5 4 3 5 3 5 3
4 4 L3-L1 L3-L1 L3-N
KZ 18415 KZ 18416 KZ 18417 KZ 18418 KZ 18419 KZ 18420 KZ 18421 KZ 18422F KZ 18423F KZ 18434
1 2 1 2
3
1 2
3
1 2
3
1 2
3 7
1 2
3 7
8 1 2
3
ARRET
MAR-
CHE
MAIN
AUTO HAND
0
AUTO 3
4 5 4 6 5 4 6 5 4 6 4
5
KZ 18436F KZ 18451
ARRET 0
GAUCHE DROITE 1 2
4
60°
KZ 18061 KZ 18630 KZ 18631 KZ 18632 KZ 18634 KZ 18635 KZ 18637 KZ 18068
0 0 0 0 0 0 STOP START
1 2
1 2 1 1 1 1
5
2 2 2 2
3
90°
KZ 18091 KZ 18093 KZ 18913 KZ 18931F
0 0 0 ARRET
MAR-
3 1 1 1 CHE
6
2
2
7
1 CHE
45 x 45 mm legends - unmarked
Colour Sold in Unit reference Weight
lots of kg
Black 20 KZ 17 0.003
Metallic
Yellow
20
10
KZ 18
KZ 19
0.003
0.003
8
60 x 60 mm legends - marked (2)
Black text on metallic background
45° 60° 90°
KZ 21041 KZ 21412 KZ 21048 KZ 21451 KZ 21635 KZ 21637 KZ 21910 KZ 21093
0 1 L1-L2 0 L1-L2
L2-
L3
L2-
L3
2
0
1
1 0 2 0 0
STOP START
0
1
9
L3-L1 L3-L1
60 x 60 mm legends - unmarked
Colour Sold in Unit reference Weight
Black
lots of
20 KZ 20
kg
0.005 10
Metallic 20 KZ 21 0.005
Yellow 10 KZ 22 0.005
(1) Weight = 0.003 kg.
(2) Weight = 0.005 kg.
3/69
References 3
Cam switches 3
45°
2 XBC Y7220 XBC Y7221 XBC Y7222 XBC Y7223 XBC Y7224 XBC Y7225 XBC Y7230 XBC Y7231 XBC Y7232 XBC Y7233
1 1 1 1 1 1 0 0 0 0
2 2 2 2 2 8 2 1 1 1 1
3 3 3 3 7 3 7 3 2 2 2 2
4 4 6 4 6 4 6 4 3 3 5 3
5 5 5 5 4 4
XBC Y7234 XBC Y7235 XBC Y2213 XBC Y2214 XBC Y2215 XBC Y2216 XBC Y7217 XBC Y7251
3 6
0
1
2 6
7
0
1
2
1
0
2 L1-N
0
L1-L2
L2
L3
L1-L2
L2
L3
0
L1-N
L2
N
0
L1-N
L2
N
0
L1-L2
L2
L3
0
1
5 3 5 3
4 L3-L1 L3-L1 L3-N L3-N L3-L1
4
60°
XBC Y7212 XBC Y7240 XBC Y7241 XBC Y7242 XBC Y7243 XBC Y7268 XBC Y7168 XBC Y7064
0 0
4
0 Marche Arr t ON OFF EIN AUS
1 2 Y
Y Y Y 1
90°
XBC Y2211 XBC Y2218 XBC Y2219
0 0 1
5
I 3 1 4 2
2 3
10
3/70
References 3
Cam switches 3
KZ 13
With 60 x 60 mm front plate (1) – 5 KZ 15 0.010
2
3
KZ 15
With marked legend Circular, with Ø 29 mm collar 1 2 1 KZ 1 0.003
2 0 1 5 KZ 2 0.003 4
KZ 01R
2O1
Without legend With 45 x 45 mm front plate (1) – 20 KZ 14 0.003
5
KZ 2
6
KZ 76
Blank legends (for engraving) for legend holders
KZ 14 Description For use Sold in Unit reference Weight
with heads lots of kg
Legend for legend holder With 45 x 45 mm front plate (1) 20 KZ 76 0.002
KZ 14
Plastic with metallic finish.
Self-adhesive. 7
For engraved markings.
KZ 16
For engraved markings.
8
(1) Operating heads for single Ø 22 mm hole or 4 hole mounting.
10
3/71
References 3
Cam switches 3
Handles
Description Colour Dimensions Sold in Unit reference Weight
1 mm
lots of
kg
New shape Black 35 5 KZ 27H 0.007
2 42 5 KZ 42H 0.009
42 5 KZ 28 0.009
Accessories
3 KZ 27 Description For use with Dimensions Sold in
lots of
Unit reference Weight
mm kg
Door interlocking plate Rear mounting switches 45 x 45 5 KZ 32 0.010
6 KZ 83
7
KZ 127
KZ 140
KZ 141
10
3/72
References (continued) 3
Cam switches 3
Accessories (continued)
Description For use with Sold in Unit reference Weight
Length = 60 mm 3 KZ 50 0.013
8 contacts 1 KZ 36 0.020 3
12 contacts 1 KZ 37 0.004
16 contacts 1 KZ 38 0.040
20 contacts 1 KZ 39 0.050
KZ 31 KZ 95 8
9
KZ 91H
10
3/73
Dimensions 3
Cam switches 3
e e e
2
a a1 a2
3 Front mounting by 6 screws Ø 5.2 mm and 55 x 100 mm front plate for cam switch with key operated lock
With plastic base and key locking Panel cut-out
Ø 5,2 Ø 10
e
4
36
18
50
50
5 a 36
Ø 43,5
a a1 a2
KpA pppp, KpB pppp 53 70.5 64
10
3/74
Dimensions (continued) 3
Cam switches 3
Bodies
Front mounting “multi-fixing”, 2 or 4 screws Front mounting by Ø 22 mm hole
45
With plastic base
36
1
6,1 6,1
50
36
45
30
36
35 a2 45
2
a
a1 36
Front mounting by Ø 22 mm hole Rear mounting
With metal base, secured by needle screws
(1)
3
36
a3 45 36 36 a4
200 maxi
45
30
36
10
35
35
36
8
(1) Ø 10 mm central hole for operating shaft
access. 2 or 4 holes for cam switch fixings
(choice made by installer).
For Ø 22 mm hole, front mounting bodies - with 45 x 45 mm front plate
KpC 1H, KpC 1Hpp, KpC 1LH KCC 1Y KpC 1S, KpC 1Z KZ 13, KZ 14
9
M22x1,5
M22x1,5
Panel cut-out
M22x1,5
34 42,5 34 42,5 35 34
3
12,7
44,5
45
45
45
35
35
22,5
45 10
3/75
Dimensions (continued) 3
Cam switches 3
34 42,5 35 34
M22x1,5
M22x1,5
60,5
3
12,7
60
60
2
42
22,5
60
3 For Ø 22 mm hole, front mounting bodies - with Ø 29 mm metallic finish plastic bezel
Head + adaptor plate
KpA 1H KpA 1S, KpA 1Z KZ 01R, KZ 1, KZ 2
Panel cut-out
M22x1,5
M22x1,5
34 42,5 35 34
3
12,7
37
4
38
35
22,5 30
5 For Ø 22 mm hole, front mounting bodies - with Ø 28.5 mm chromium plated metal bezel
KAX Z1M1p + KZ 127 KAX Z1C1p + KZ 127
Panel cut-out
28,5
6
34
22,5
25 25
8 22,5
22 21
9 34 26 45 26
Panel cut-out
10
44,5
45
45
36
35
10 36 45
3/76
Dimensions (continued) 3
Cam switches 3
60,5
60
36
42
36
60
c1
c G
a
Kpp-I061G,
Kpp-K062G,
5
Kpp-K053G
7
26
R10
0
Contact closed 8
Contact closed in 2 positions and maintained between the 2 positions
Overlapping contacts 9
Spring return position: for a switching angle of 90°, spring return is over 30° after the last position (for a maximum of 3 simultaneous contacts).
Example:
0
10
90
120
3/77
References 3
Cam switches 3
A kg
1 – – – 10 KA1 A050G 0.365
16 KA2 A050G 0.365
3 3 – – – 10
16
KA1 C051G
KA2 C051G
0.390
0.390
5 3 1 1 1 10
16
KA1 F056G
KA2 F056G
0.704
0.704
8
9 – 1 (4) – 10 KA1 K063G 0.719
16 KA2 K063G 0.719
(1) To order a switch with a red padlockable handle (up to 3 padlocks), replace the letter A
(2nd letter) in the references shown above by the letter C.
Example : KA1 A050G becomes KC1 A050G.
(2) Poles : main contacts
v N/O contact : late make (unballasting contact)
9
v N/C contact : signalling contact
v Neutral conductor (N) : early make, late break.
(3) Permissible power, AC-23 at 400 V :
v K1 switches : 2.2 kW,
v K2 switches : 5.5 kW.
(4) Contact not late make.
10
Dimensions:
page 3/77
3/78
References (continued) 3
Cam switches 3
OFF-ON switches
Specifications
b PVC enclosure.
b 60 x 60 mm operating head, black handle (without padlocking device) on metallic
1
background. Marking: O I.
b Legend holder with metallic finish blank legend.
3 – – – 10
16
KD1 C051G
KD2 C051G
0.390
0.390
3
3 1 – – 10 KD1 D052G 0.400
16 KD2 D052G 0.400
8
9 – 1 (3) – 10 KD1 K063G 0.749
16 KD2 K063G 0.749
9
v K1 switches : 2.2 kW,
v K2 switches : 5.5 kW.
(3) Contact not late make.
10
Dimensions:
page 3/77
3/79
References 3
Cam switches
Complete switches, 12 A with key operated lock
Front mounting by 6 screws Ø 5.2 mm
with 55 x 100 mm front plate
1 2
2
3
4 3
5
2
6
1 2 3
0
60
0 60 120
1 120 Black K1C 003NZ4 0.170
2
3
3 K1C 003NZ2
4
5
6
2-pole
4 1
2
3
L1 L2
1
2
Red K1F 013NZ2 0.170
4
5 3
6
7
8
9
10
11
12
5 1 2 3
0
60
120
0 60 120
1
Black K1F 013NZ4 0.170
2
3
4
5
6
7
6
8
9
10
11
12
3-pole
L1 L2 L3
1 1 Red K1l 023NZ2 0.170
7
2 2
3
4
5 3
6
7
8
9
10
11
12
13
14 0
15 60
8
16
17
18 120
1 2 3
0 60 120
1
Black K1l 023NZ4 0.170
2
3
4
5
9
6
7
8
9
10
11
12
13
14
15
16
17
18
10
3/80
References (continued) 3
Cam switches 3
L1 L2 L3 L4 1
1 2 Red K1Q 034NZ2 0.170
2
3
4 3
5 4
2
6
7
8
9
10
11
12
13 0
14
15 60
16
17 120
18
19 180
Black K1Q 034NZ4 0.170
3
20
21
22
23
24
25
26
27
28
29
30
31
32
4
1 2 3
1
L1 L2 L3 L4 1
2
Red K1Q 8621Z1 0.170
2
3
4 3
5 4
6
7
8
9
10
5
11
12
13
14 0
15 60
16
17 120
18
19 180
20
6
21
22
23
24
25
26
27
28
29
30
31
32
1 2 3 4
7
0 30 60 90 120 150 180
1
2
3
4
5
6
7
8
9
10
11
12
8
13
14
15
16
17
18
19
20
21
22
9
23
24
25
26
27
28
29
30
31
32
(1) Switching programme identical for 4 step and 4 step with intermediate steps at 30°.
10
3/81
References (continued) 3
Cam switches 3
L1 L2 0
1 Red K1D 012QZ2 0.170
562791
2 1
3
4
5 2
2
6
7
8
1 2
0
60
3
2
3
4
K1D 012QZ2 5
6
7
8
3-pole
4 1
2
L1 L2 L3 0
1
Red K1F 022QZ2 0.170
3
4
5 2
6
7
8
9
10
11
12
5 1 2
0
60
120
Black K1F 022QZ4 0.170
0 60 120
1
2
3
4
5
6
6
7
8
9
10
11
12
4-pole
8 16
1 2
120
9 7
8
9
10
11
12
13
14
15
16
10
3/82
References (continued) 3
Cam switches 3
3
20
21
22
23
24
5
L1 L2 0
1 5 1 Red K1K 015NZ2 0.170
2
3
4 4 2
5 3
6
7
8
9
10
11
12
13 0
14
6
15 300 60
16
17 240 120
18
19 180
20 Black K1K 015NZ4 0.170
1 2 3 4 5
7
5 step with intermediate steps at 30°
0 30 60 90 120 150 180 210 240 270 300 0
1 5 1 Red K1K 1060Z1 0.170
2
8
3
4
5 4 2
6
3
7
8
9
10
11
12
13
14 0
15 300 60
16
17
18
19
20
240
180
120
9
(1) Switching programme identical for 5 step and 5 step with intermediate steps at 30°.
10
3/83
References (continued) 3
Cam switches 3
0 60 120 180 0
1 1 Red K1D 032RZ2 0.170
2
3
4 2
5 3
2
6
7
8
0
60
Black K1D 032RZ4 0.170
120
180
3 K1D 032RZ2
2-pole
0 60 120 180 0
1 1 Red K1G 043RZ2 0.170
2
4 3
4
5
6
3
2
7
8
9
10
11
12
13
14 0
60
Black K1G 043RZ4 0.170
5 180
120
4 2
5 3
6
7
8
9
10
11
12
13
0
7
14
15 60
16
17
18 120
180
10
3/84
References (continued) 3
Cam switches 3
1 1
2
3
4 4 2
5 3
6
7
2
8
9
10
11
12
13
14 0
15 60
16
17
18 240 120
19
20 180
21
22
K1B 001UZ2
3
23
24
25
26
27
28
29
30
31
32
kg
4
1-pole
300 0 60 0
1 1 2 Red K1B 001UZ2 0.170
2
3
5
4
2-pole 6
300 0 60 0
1 1 2 Red K1D 002UZ2 0.170
2
3
4
5
6
7
7
8
3-pole
L1 L2 L3 0
Red K1F 003UZ2 0.170
8
1 1 2
2
3
4 1-pole
5
6
7
8 2-pole
9
10
9
11
12 3-pole
0
1 2 300 60
300 0 60
1
Black K1F 003UZ4 0.170
2
3
4
5
6
7
10
8
9
10
11
12
3/85
General 3
Cam switches 3
The range of K30 to K150 cam switches (32 to 150 A ratings) comprises only
complete switches.
1 These products are more specifically designed for direct control of simple machines.
b switches
b ON-OFF switches
b changeover switches
2 b
b
b
star-delta switches
pole change switches
reversing switches
By 4 holes By 4 holes
4 with 64 x 64 mm front plate with 88 x 88 mm front plate
32 to 63 A ratings 115 to 150 A ratings
K30, K50 and K63 K115 and K150
9 By 4 holes on 48 mm centres
32 to 63 A ratings
By 4 holes on 68 mm centres
115 to 150 A ratings
K30, K50 and K63 K115 and K150
10
3/86
Characteristics 3
Cam switches 3
3
Degree of protection
Conforming to IEC 60529 IP 40
Mechanical life 300,000 operating cycles
4
Conventional thermal Screw clamp terminals In open air Ith = 32 A Ith = 50 A Ith = 63 A Ith = 115 A Ith = 150 A
current
Rated operational characteristics
Conforming to a AC-15 220…240 V 14 A 16 A – – –
EN/IEC 60947-5-1 380…440 V 6A 7A – – –
Conforming to a AC-3 3-phase 220…240 V 5.5 kW 7.5 kW 11 kW 15 kW 22 kW
EN/IEC 60947-3 3-pole 380…440 V 11 kW 15 kW 18.5 kW 30 kW 37 kW
5
660…690 V 11 kW 15 kW 18.5 kW 30 kW 30 kW
1-phase 110 V 2.2 kW 2.5 kW 3 kW 3.7 kW 5.5 kW
2-pole 220…240 V 4 kW 5.5 kW 6 kW 7.5 kW 11 kW
380…440 V 5.5 kW 7.5 kW 11 kW 13 kW 18.5 kW
a AC-23A 3-phase 220…240 V 7.5 kW 11 kW 15 kW 30 kW 37 kW
3-pole 380…440 V 15 kW 22 kW 30 kW 45 kW 75 kW
660…690 V 15 kW 22 kW 40 kW 45 kW 55 kW
1-phase
2-pole
110 V
220…240 V
2.2 kW
4 kW
2.5 kW
5.5 kW
4 kW
10 kW
5.5 kW
15 kW
11 kW
22 kW 6
380…440 V 7.5 kW 11 kW 18.5 kW 22 kW 37 kW
a AC-21A 32 A 40 A 63 A 100 A 150 A
7
Short-circuit protection Cartridge fuse 50 63 80 125 200
type gG, A
Rated impulse withstand voltage U imp = 6 kV conforming to EN/IEC 60947-1
Connection Captive screw clamp terminals (For 2 x 2.8 x 0.8 mm push-on connectors, please consult your
Regional Sales office)
Solid cable
Flexible cable with or without
2 x 6 mm2
2 x 4 mm2
2 x 10 mm2
2 x 6 mm2
2 x 16 mm2
2 x 10 mm2
1 x 35 mm2
1 x 25 mm2
1 x 70 mm2
1 x 50 mm2
8
cable end
Tightening torque 1.2 N.m 2 N.m 2.5 N.m 2.5 N.m 2.5 N.m
3/87
References 3
Cam switches 3
2 1
L1 L2L3 N L1L2
50 K50 A001AP 0.175
2
3
4
5 0
60
6 2 32 K30 B002AP 0.170
7
K30 C003AP 8
9
3
10
11 50 K50 B002AP 0.215
12
UV WN UV
Output 1 Output 2 3 32 K30 C003AP 0.224
0 60
1-pole 1
103522
2
2-pole 3 50 K50 C003AP 0.275
4 3-pole
4-pole
4
5
6
7
8
9
10 63 K63 C003AP 0.345
6-pole 11
12
10
3/88
References (continued) 3
Cam switches 3
2
ON
1
2
3 50 K50 C003HP 0.275
4
5 0
6
7 90
K63 C003HP 8 63 K63 C003HP 0.345
UV WN
Output
115 K115 C003HP 0.680 3
0 90
1
2
501178
3
4
150 K150 C003HP 0.790
3-pole 5
6
4-pole 7
8
4 32 K30 D004HP 0.250
4
50 K50 D004HP 0.305
5
115 K115 D004HP 0.745
Rear mounting
6
Input OFF 3 32 K30 C503HP 0.250
L1 L2L3 N ON
1
2 50 K50 C503HP 0.300
3
4
5
6
7
8
0
Output
115 K115 C503HP 0.720
0 90
1
3-pole
2
3
4
5
150 K150 C503HP 0.830 8
6
4-pole 7
8
4 32 K30 D504HP 0.280
9
50 K50 D504HP 0.350
10
150 K150 D504HP 0.930
3/89
References (continued) 3
Cam switches 3
Input 1 Input 2
1
0
2
1 32 K30 B001UP 0.170
L1 L2L3 N L1L2L3 N
1 50 K50 B001UP 0.215
2 2
3
4
150 K150 B001UP 0.790
5
6 2 32 K30 D002UP 0.250
7
8 0
50 K50 D002UP 0.305
9 300 60
K50 B001UP 10
11
12
3 32 K30 F003UP 0.425
3
13
14 50 K50 F003UP 0.530
15
16 UV WN 63 K63 F003UP 0.590
115 K115 F003UP 0.645
300 0 60
1
2
150 K150 F003UP 0.760
3
1-pole 4
5
6 4 32 K30 H004UP 0.485
2-pole 7
8
50 K50 H004UP 0.610
4
9
10
3-pole 11
12
63 K63 H004UP 0.680
13
14 115 K115 H004UP 0.750
4-pole 15
16 150 K150 H004UP 0.880
6 8
9
10
63 K63 F013UP 0.590
11
12
UVW
115 K115 F013UP 0.645
330 30
1
2
3
4
5
K63 F013UP
7
6
7
8
9
150 K150 F013UP 0.760
10
11
12
Input 1 Input 2
1 2
4 32 K30 H014UP 0.485
8 330 30
50 K50 H014UP 0.610
9
330 30
1
2
3
115 K115 H014UP 0.750
4
5
6
7
8
9
10
10
11
12 150 K150 H014UP 0.880
13
14
15
16
3/90
References (continued) 3
Cam switches 3
Star-delta switches
Front mounting
Wiring diagram
and
Marking Number Thermal
and switch of current
Reference Weight 1
switching programme position poles (Ith)
A kg
103522
L1 L2L3
3 32 K30 H001YP 0.485
1 0
2
3
4
5
6
2
7 50 K50 H001YP 0.610
8
9 0
10 300 60
11
K50 H001YP 12
13
14 63 K63 H001YP 0.680
15
16
W2
W1
U1
U2
3
V2 V1
300 0 60
1
2
3
4
4
5
6
7
150 K150 H001YP 0.880
8
9
10
11
12
13
14
15
16
L1 L2 L3
3 32 K30 K006YP 0.560
501177
0
1
2
3
6
4
5
6
7 50 K50 K006YP 0.690
8
9 0
315 45
10
11 270 90
12
13
14 63 K63 K006YP 0.770
15
7
16
17 W2 U1
K115 K006YP 18
19 W1 U2
20
V2 V1 115 K115 K006YP 0.880
290 315 0 45 90
1
2
8
3
4 150 K150 K006YP 0.990
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
9
20
10
3/91
References (continued) 3
Cam switches 3
2 4
5
6
7
8 0
9 1U
300 60
10
11
12 2V 2U 50 K50 H004PP 0.610
K63 H004PP
13
14
15
3 16 1W 2W 1V
300 0 60
1
2
3
4
5 63 K63 H004PP 0.680
6
7
8
9
10
11
4
12
13
14
15
16
1 0
2 32 K30 D002WP 0.250
5
1 2
2
3
4
5 U V 50 K50 D002WP 0.305
6
7
8 M 0 63 K63 D002WP 0.390
300 60
300 0 60
1
2 115 K115 D002WP 0.745
3
6
4
5
6
7 150 K150 D002WP 0.880
8
K150 D002WP
L1 L2 L3
1 0
1 2 3 32 K30 E003WP 0.385
2
3
4
5 50 K50 E003WP 0.485
7
6
7
8 0 63 K63 E003WP 0.540
9 300 60
10 U V W
11
12 115 K115 E003WP 0.590
M
8
4
5
6
7
8
9
10
11
12
Accessories
Description For use with Sold in Unit reference Weight
lots of kg
9 Legend holders
With blank legend
Square heads
64 x 64 mm
5 KZN 15 0.020
3/92
Dimensions 3
Cam switches 3
D1 1
b
b
e
G1 34 X a a1
2
34 a
K30 A K30 C K30 E K30 H K30 K K50 A K50 C K50 E K50 H K50 K K63 A K63 C K63 E K63 H K63 K
K30 B K30 D K30 F K50 B K50 D K50 F K63 B K63 D K63 F
a 41 53.7 66.4 79.1 104.5 45.8 63.3 80.8 98.3 133.3 49.8 71.3 92.8 114.3 157.3
a1 6
b 58
6
58
6
58
6
58
6
58
6
60
6
60
6
60
6
60
6
60
6
66
6
66
6
66
6
66
6
66
3
U 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64
D1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 5.4 5.4 5.4 5.4 5.4
G1 – 48 – – – – 48 – – – – 48 – – –
X – 78 to 97 – – – – 78 to 97 – – – – 78 to 97 – – –
4
K115 A K115 C K115 E K115 H K115 K K150 A K150 C K150 E K150 H K150 K
K115 B K115 D K115 F K150 B K150 D K150 F
a 61.5 88 114.5 141 194 67.5 100 132.5 165 230
a1 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9
b 84 84 84 84 84 88 88 88 88 88
U 88 88 88 88 88 88 88 88 88 88
D1 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4
5
G1 – 68 – – – – 68 – – –
X – 120 to 150 – – – – 120 to 150 – – –
e: support panel thickness 0.5 to 5.5 mm.
Panel cut-out
D3 D2
6
G2
K30/K50/K63 K115/K150
D2 4.5 6
D3 10 13
G2 G2 48 68
7
Convention used for switching programme representation
Link positions (factory mounted) Graphic representation of switching positions and spring return to “0” position
L1 L2 L3
315 0 45
1 1
2
3
4
2
3
4
5
8
5
6 6
7 7
8 8
9 9
10 10 Contact terminal reference number
UVW
Contact closed
10
315 45
Overlapping contacts
3/93