ASME U Stamp

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

“U” STAMP ENGINEERED EXPANSION JOINTS

ASME “U” Stamp


Expansion Joints

Since 1997 MACOGA has been The ASME U Code Symbol


designing and supplying Requirements
expansion joints in accordance
with ASME Section VIII, Div 1 The requirements of applying a U Code Symbol to an
Expansion Joint encompass the whole process from
Appendix 26 providing ASME design to purchasing to production and testing.
Code Stamp and U-2 Partial Starting right with the design, there are rules to be
Data Reports. followed. Parameters such as wall thicknesses,
materials, welding details, and extent of non-destructive
The ASME International Boiler examination are determined by design conditions
and Pressure Vessel Code such as pressure, temperature, and corrosion allowance,
fluid running through the Expansion Joint, and any
establish rules governing the specific requests from the customer. Based on these
design, fabrication, and conditions a comprehensive set of calculations are
prepared. They are reviewed and approved by the
inspection of boilers and ASME Inspector.
pressure vessels, and nuclear
power plant components Once the design has been approved, the materials
can be purchased and must comply with the Boiler
during construction. The ASME and Pressure Vessel Code. All material must be clearly
Boilerand Pressure Vessel Code identified to trace it to the applicable Material Test
Report. The ASME Inspector will check the material
is in a class of its own and it is and review the Material Test Reports to ensure their
internationally renowned. conformity to the Code.
Before production can begin, the Inspector will verify
that the weld procedure to be used has been qualified
and the welders performing the welding are certified.
This is in accordance with Section IX. The next step
is to review the unit after fabrication is complete
to ensure welding was performed to Code require-
ments and all non-destructive testing results.

The Authorized Inspector will witness the hydrostatic


test performed in accordance with the requirements
of Section VIII Division 1.

The final step is the application of the nameplate. This


is also witnessed by the Inspector. The nameplate
will be marked with relevant design conditions and
the U Code Symbol.

Any Expansion Joint stamped with this symbol has


been built strictly in accordance with the provisions
of the ASME Boiler and Pressure Vessel Code.

Leira. s/n. 15680 Ordenes. La Coruña, Spain. Tel: (+34) 981 68 00 00. Fax: (+34) 981 68 02 38
ENGINEERED EXPANSION JOINTS www.macoga.com e-mail: [email protected]