PIEZOMETERS
USER MANUAL
www.sisgeo.com Casagrandeandstandpipepiezometer_EN_00_14
CASAGRANDE and STANDPIPE PIEZOMETERS
DescriPTION Page 5
InstallaTION Page 6
Troubleshooting Page 10
maintenance Page 10
Notes on the use of product For safe and efficient use of the product, please read carefully the following
instructions before starting any operation.
Any use of the product other than the one described in this manual shall be considered the
user’s full responsibility.
The same applies for any unauthorized modifications.
In addition to the hereby listed standards, the user must comply with the provisions of the
current legislation regarding personal safety and health together with all other persons in the
workplace.
SISGEO is not responsible for any accident, breakdown or other problems due to lack of
knowledge and / or non-compliance with the requirements contained in this manual.
Check that the product has not been damaged during the transport.
Verify that the package includes all items as well as any requested optional accessories; if
anything is missing, please promptly contact SISGEO.
The user must strictly follow all the operations described in this manual.
Maintenance or repair of the device is permitted only by authorized operators.
These operators must be physically and intellectually suitable.
For information about instrument or to order spare parts, always specify the product
information which can be found on the identification label.
When replacing parts, always use ORIGINAL SPARE PARTS.
The manufacturer reserves the right to make either technical and / or commercial changes
without prior notice.
It is our policy to keep manuals continuously updated.
Symbols
unit
3 1
Usually the filter that has to be saturated is left in a container full of water for 24 h before
the installation.
The saturation is more effective if the water had been previously de-aerated making it boil
for at least 10 minutes and then make it cool.
The needed tools are: depth meter, bentonite pellets, teflon tape, adhesive tape, jig saw.
tmeasure casing
covering casing
100cm
sand or gravel
70cm
depth meter
filter cell
70cm
sand or gravel
50cm
measure casing
covering casing
100cm
70cm
depth meter
filter cell
70cm
sabbia o ghiaia
50cm
GENERAL RECOMMENDATIONS
• Saturate the cell as explained in the previous paragraph;
• flush accurately the hole with clean water until doesn’t get out clear water;
• use fine sand or gravel (Ø max 0.5 cm);
• if the piezometer is expected to be at an intermediate quote, fill in the empty part with
a mix of water/cement/bentonite in order to recreate the consistency of the original
ground;
• wrap the teflon on the threads to secure the holding. Join two casings using the
couplings;
• be careful when you screw the casings to the filter cell. Handle the cell using the black
upper junction. DO NOT handle it by the filter. Screw without forcing. If there is a
double casing, tie them together with adhesive tape;
• lower the casings in the borehole by hand. Be careful. Don’t use pliers;
• let the casing stick out the ground for 20-30 cm (if necessary);
• recover the coverings ensuring that the instrument will not be lifted;
• use the protective cap to protect the casing.
To create the cap, pour the bentonite in more stages; each layer shouldn’t be more than
25÷30 cm thick.
Compact the bentonite pellets with a pestle (not supplied) of suitable dimensions.
Verify with the depth meter the solidity of the cap and the quote reached.
Note: if there is a waterproof ground coat higher then the layer you have been measuring, it
is recommended that the bentonite cap is made at the same height of the layer to restore
the continuity.
If you need to install two piezometers (with two different layers) in the same borehole, it
will be necessary to make two filtering coats and two seals.
Pay attention to the stratigraphy and to the permeable and waterproof ground’s coats
thickness.
In this case the internal diameter of the casings must not be less then 110mm.
TAKING To perform a measurement you have to gather the water level quote within the casing,
1. Drop carefully the probe in the piezometer casing until you hear a sound and the led
switches on;
2. lift the probe until the sound stops;
3. if necessary shake a little the graduated tape to remove any drop of water that would
stick on the probe and create a false signal;
4. drop slowly the graduated tape until you reach precisely the level;
5. gather the value in the chosen reference point;
6. rewind the tape on the reel;
7. clean accurately the probe. Do not use solvents or strong detergents.
CASAGRANDE PIEZOMETER
Servizio After-sales assistance for calibrations, maintenance and repairs, is performed by SISGEO’s
http://www.sisgeo.com/repairs.html
Send back the instrument/equipment with the complete accessories, using suitable
packaging, or, even better, the original ones.
The shipping costs shall be covered by the sender.