TYPE/ENC, Frame Amps 100, Trip Amps 50, 2 Poles, 240 Volts, Reconditioned Price $225.00
TYPE/ENC, Frame Amps 100, Trip Amps 50, 2 Poles, 240 Volts, Reconditioned Price $225.00
22-4572
100
50
2
"
Stock # 22-4572, GENERAL ELECTRIC, Circuit Breaker, Catalog No. GO
TYPE/ENC, Frame Amps 100, Trip Amps 50, 2 Poles, 240 Volts,
Reconditioned Price $225.00
"#$%&%%
22-17518
100
100
2
"
Stock # 22-17518, GENERAL ELECTRIC, Circuit Breaker, Catalog No.
SEDA24AT0100, Frame Amps 100, Trip Amps 100, 2 Poles, 240 Volts,
Reconditioned Price $75.00
'
The SEDA24AT0100 Circuit Breaker has been reconditioned per MIDWEST's rigorous service procedures
based on 30 years experience. The SEDA24AT0100 circuit breaker has been maintained and refurbished
per industry standards and per MIDWEST's Quality Control Program (QCP). The services include
applicable internal and external procedures, repairs, and replacement of deficient components. In
addition to standard electrical tests, MIDWEST also performs live function tests on the SEDA24AT0100.
These services far exceed the routine reconditioning of the SEDA24AT0100 performed by many circuit
breaker vendors and resellers. MIDWEST certifies the SEDA24AT0100 circuit breaker has passed our
QCP before shipping.
(
'
A "New Surplus" Circuit Breaker is a circuit breaker that has never been installed, but is not "New from
the Factory" or "New from the Manufacturer or Distributor" of the SEDA24AT0100 circuit breaker. It
may be referred to as New in the Box, New Surplus, Never Installed, Never Energized, or other such term
that avoids the label "New from the Manufacturer." A New Surplus SEDA24AT0100 circuit breaker
should not be considered new from the manufacturer or manufacturer's Distributor. Surplus and New
Surplus SEDA24AT0100 circuit breakers must pass MIDWEST's (QCP) Quality Control Program.
)*(
'
MIDWEST has tested, maintained, and reconditioned electrical switchgear, including circuit breakers, for
over 30 years. When asked if one should purchase a used or reconditioned circuit breaker instead of a
new breaker, MIDWEST recommends purchasing the new breaker. The availability of used circuit
breakers in the market place does not suggest a used breaker is better than a new breaker. Equipment
has a reliable life expectancy and there is an expectation that new equipment has an improved design.
We know that select older equipment may be more reliable in some cases because the older equipment
was overbuilt and therefore suffers an abusive environment possibly better than some newer
equipment. But this statement does not permit a blanket statement suggesting used and reconditioned
breakers are better than new breakers.
+,
,
-
The marketplace for used, obsolete, reconditioned, surplus, remanufactured, etc. circuit breakers exists
because of several critical challenges to the market for new equipment. The most critical challenge is
the availability. Many breakers are no longer available new. Many other breakers are not in stock and
may have a delivery time of weeks. If a manufacturing facility operates using a "just in time supply
chain," they require immediate availability. The only choice may be a used or reconditioned circuit
breaker.
(
$75.00
22-12929
100
20
2
"
Stock # 22-12929, GENERAL ELECTRIC, Circuit Breaker, Catalog No.
THQB2120ST1, Frame Amps 100, Trip Amps 20, 2 Poles, 240 Volts,
Reconditioned Price $55.00, New Surplus Price $75.00
-/c!
''
!
Low Voltage & Automation Products Free access to LV switchgear
Call Us Toll-Free: (877) 268-3700 functions & selection
www.abbsales.com www.electrical-installation.org
58
6 .
Two.adjoining.switchboard.sections.are.connected
..
together.with.________
..
a .
vertical.bus.bars.
b .
compression.lugs
..
c .
splice.plates. .
d .
cable
7.
A.________.is.used.when.cables.fed.from.the.
..
bottom.of.a.switchboard.need.to.be.routed.to.the.top.
..
of.the.switchboard .
..
a .
service.section.
b .
pull.section
..
c .
routing.section.
d .
distribution.section
8 .
When.________.metering.is.used,.power.is.still
..
applied.to.the.utility.meter.after.the.service.main.has
..
been.switched.off
..
a .
hot.sequence.
b .
cold.sequence
..
c .
top.feed.
.
d .
bottom.feed
9 .
The.neutral.conductor.is.________.grounded.at.the
..
service-entrance.switchboard
..
a .
never. ..
b ..
always.
..
c .
rarely. .
d .
often.
0 .
The.maximum.number.of.switches.or.circuit.breakers
..
on.service-entrance.equipment.used.to.disconnect.and
...
isolate.the.service.from.all.other.equipment.is
..
________
..
a .
.
.
.
b .
2
..
c .
6.
.
.
d .
8
.
Article.230 95.of.the.NEC®.requires.ground-fault
..
protection.of.equipment.for.solidly.grounded.wye
..
electrical.services.of.more.than. 50.volts.to.ground,
..
but.not.greater.than.600.volts.phase-to-phase.for.each
..
service.disconnecting.means.rated.________.amps
..
or.more
..
a .
00. .
b .
000
..
c .
0,000.
d .
00,000
2 .
Which.of.the.following.devices.can.be.used.as.a.main
..
protective.device.in.a.Siemens.switchboard?
..
a .
molded.case.circuit.breaker
..
b .
fusible.switch
..
c .
Insulated.case.circuit.breaker
..
d .
all.the.above
60
quickSTEP Online Courses
Siemens.quickSTEP.online.courses.are.available.at.
http://www sea siemens com/step/default html
The.quickSTEP.training.site.is.divided.into.three.sections:.
Courses,.Downloads,.and.a.Glossary .The.Courses.page.
provides.links.to.online.courses.which.include.reviews,.a.final.
exam,.the.ability.to.print.a.certificate.of.completion
The.Downloads.page.provides.links.to.the.complete.text.of.all.
STEP.courses.can.be.downloaded.in.PDF.format .These.files.
contain.the.most.recent.changes.and.updates.to.the.STEP.
courses .
A.unique.feature.of.the.quickSTEP.site.is.our.pictorial.glossary .
The.pictorial.glossary.can.be.accessed.from.anywhere.within.
a.quickSTEP.course .This.enables.the.student.to.look.up.an.
unfamiliar.word.or.phrase .
Finally,.this.great.value.is.available.at.no.charge.to.anyone.
interested.in.learning.more.about.Siemens.produ