Small Sterilizer
Small Sterilizer
Under the object to produce the high quality medical device, the company
has adopted quality management system for the purpose of applying to
global standard, and so we have made an effort for the technical
development steadily. As a result, the products have been approved with
its excellence of quality by internationally reputable certificates such as
CE mark according to MDD (93/42/EEC, Annex II) and Quality System
Standards
.. (EN ISO 9001: 2008 / EN ISO 13485: 2003+AC:2007) from
TUV NORD, and other certificates such as KS and KGMP.
2 HANSHIN
www.hanshinmed.co.kr / www.eurohanshin.com
HANSHIN 3
B Class Steam Sterilizer
Pre-vacuum Air Removal & Vacuum Drying
4 HANSHIN
Contents
category
B Class
Pre-vacuum Air Removal & Vacuum Drying HS-2519VH HS-3241VH
HS-2321V HS-3041V
B Class
Pre-vacuum Air Removal & Vacuum Drying HS-2321BD
HS-3041BD
B Class
Pre-vacuum Air Removal & Vacuum Drying HS-2519BTJ HS-3241BTJ
HS-2321BT HS-3041BT
HS-1606VD HS-2519VD
S Class
Gravity Air Removal & Vacuum Drying
Digital LED Display Type HS-2321VD HS-3041VD
HS-3460VD HS-60VD
HANSHIN 5
Graphic LCD Type Steam Sterilizer
Vacuum-Hollow & Vacuumclave
VH/V series
Until recently air removal of chamber and drying based on the employ of the vacuum system has been used
exclusively for the large steam sterilizer. Our company has adopted the vacuum system for the small sterilizer
despite the various restrictions, thereby satisfying the requirements of the standards (MDD) of EU. This is very
meaningful that air removal based on the pre-vacuum system is adopted in sterilizing the wrapped items and the
drying based on the post vacuum system is also very important in the sense that the drying of sterilized items is
as important as sterilization.
In sterilization, it is important to ensure that the sterilant contacts with the entire
surface of the goods to be sterilized. To make this possible, all the air inside the
goods and the pack should be removed. It was almost impossible to remove
completely air bubbles in hollow loads, such as those in tubes, not to mention
the air bubbles in porous loads like the sponges. Our company has worked
hard to develop a table-top steam sterilizer of the high-degree vacuum type,
which can pass the Hollow Load A Test (Helix test) within 134 / 3.5min - the
shortest time ever. Meeting European Standards, the Hollow Load A Test is
used to check the ability to remove air from hollow loads. By passing this test,
this product has obtained CE mark of Europe thus becoming the next
generation’s advanced technology.
Vacuum-Hollow
HS-2519VH HS-3241VH
6 HANSHIN
B Class Steam Sterilizer
Pre-vacuum Air Removal & Vacuum Drying
Vacuumclave
HS-2321V HS-3041V
HANSHIN 7
Graphic LCD Type Steam Sterilizer
Vacuum-Hollow & Vacuumclave
VH/V series
Piping System
Vacuum Pump :
It, compact type with diaphragms, is an
aluminum ware that has a complete oilless
operation, a low noise (50~54 dBA), an
outstanding performance and a durability Electric System
against hard water.
Electronic Controlling Device :
Reservoir : PCBs (HS2321A-A, HS2321C, HS2321P) are
It contains a condensing coil, a steam trap and equipped in one box.
a water level sensor in order to supply and
withdraw water used for the sterilization.
Condenser :
It condenses the steam exhausted during
the drying phase.
Safety Valve :
It prevents a possible damage from
excessive pressure in the chamber.
Air Filter :
The bacteria-retensive filter which can
filter out 99.999% (conform to EN13060) Heater :
of 0.3 particles filters outside air There is no damage risk of loads since the heater is
supplied into the chamber during the vent equipped in the Jacket. In the case that the heater is
and drying phase. It prevents sterilized exposed to the air, the thermostat sensor shuts off
items from a recontamination by bacteria the power supply, and then gives an alarm.
in the air.
8 HANSHIN
B Class Steam Sterilizer
Pre-vacuum Air Removal & Vacuum Drying
HANSHIN 9
Graphic LCD Type Steam Sterilizer
Vacuum-Hollow
HS-2519VH / HS-3241VH
This small steam sterilizer delivers enhanced sterilization performance by combining an
innovative cycle program and a powerful vacuum system for air removal. It can meet the
Sterility Assurance Level (SAL=10-6 CFU: EN 556) for hollow loads with materials that are very
hard to sterilize within the shortest time. It is also equipped with self-diagnosis and alarm
functions, a large LCD display, a printer for printing out the cycle performance record, and a
door interlock system among other features.
HS-2519VH
HS-3241VH
Cycle Program
Test Cycle Program
Items Basic Cycle Program
Bowie-Dick / Helix Vacuum Leak
Cycle No. 1 2 3 4 5 1+TEST PRG. 2+TEST PRG.
Load Type Wrapped Unwrapped Liquid Test Pack / PCD N/A
Exposure Temperature 134 121 134 121 121 134
Exposure Time 4min 15min 4min 15min 30min 3.5min Dwell: 5min
Dry Time 5min 10min 5min 10min - 5min T e s t : 10min
Cooling Time - - - - 60min -
Installation Information
Model HS-2519VH HS-3241VH
Overall dimensions of sterilizer (Net weight) W565 x D756 x H448 mm (70kg) W633 x D847 x H508mm (90kg)
Appliance Table of the sterilizer (Net weight) W590 x D660 x H821 mm (16kg) W690 x D760 x H821 mm (22kg)
Dimension of usable space W1,190 x D1,660 x H1,551 mm W1,290 x D1,860 x H1,611 mm
Load per support area (N/m ) when the 2 Reservoir fill water: 4.2kg Reservoir fill water: 4.2kg
reservoir is filled with water in full level and Max. load: 1.2kg Max. load: 3.0kg
the chamber contains a maximum load. Water pressure test: 19.5kg Water pressure test: 41.0kg
Note; if the water pressure test is required, e.g. by Load per support area: 2,300N/m2(max. load) Load per support area: 2,228N/m2(max. load)
pressure vessel regulations, this weight Load per support area: 2,761N/m2 Load per support area: 2,938N/m2
should be considered. (water pressure test) (water pressure test)
Overall clearance required(left, right, front, rear, top side) each 300 mm each 300 mm
Clearance required for door moving 400 mm 500 mm
10 HANSHIN
Cycle Graph
It has 5 kinds of basic cycle and 2 kinds of test cycle
program. The sterilization and dry time can be
reduced, and the sterility assurance level can be
achieved by performance of the vacuum system.
Moreover, it has a perfect sterilizing ability for the
Hollow Load A .
HANSHIN 11
Graphic LCD Type Steam Sterilizer
Vacuumclave
HS-2321V / HS-3041V
This sterilizer uses saturated steam as sterilizing medium, which is generated from water
heated directly by built-in heater in the chamber, and has been improved sterilizing and drying
efficiency drastically by powerful vacuum air removal. Sterilizing processes are proceeded
automatically by microprocessor control, and self diagnosis program monitors the cycle
performance in real time. Sterilizer also has a printer for printing out the cycle performance
record, and door interlock system, safety valve, overheat protector for safety.
HS-2321V
HS-3041V
Cycle Program
Test Cycle Program
Items Basic Cycle Program
Bowie-Dick / Helix Vacuum Leak
Cycle No. 1 2 3 4 5 1+TEST PRG. 2+TEST PRG.
Load Type Wrapped Unwrapped Liquid Test Pack / PCD N/A
Exposure Temperature 134 121 134 121 121 134
Exposure Time 15min 30min 5min 15min 40min 3.5min Dwell: 5min
Dry Time 30min 30min 15min 15min - 5min T e s t : 10min
Cooling Time - - - - 60min -
Installation Information
Model HS-2321V HS-3041V
Overall dimensions of sterilizer (Net weight) W516 x D714 x H405 mm (64kg) W614 x D804 x H489mm (91kg)
Appliance Table of the sterilizer (Net weight) W590 x D660 x H821 mm (16kg) W690 x D760 x H821 mm (22kg)
Dimension of usable space W1,190 x D1,660 x H1,526 mm W1,290 x D1,860 x H1,610 mm
Load per support area (N/m ) when the 2 Reservoir fill water: 4.2kg Reservoir fill water: 4.2kg
reservoir is filled with water in full level and Max. load: 2.0kg Max. load: 3.0kg
the chamber contains a maximum load. Water pressure test: 21.5kg Water pressure test: 40.5kg
Note; if the water pressure test is required, e.g. by Load per support area: 2,170N/m2(max. load) Load per support area: 2,247N/m2(max. load)
pressure vessel regulations, this weight Load per support area: 2,711N/m2 Load per support area: 3,004N/m2
should be considered. (water pressure test) (water pressure test)
Overall clearance required(left, right, front, rear, top side) each 300 mm each 300 mm
Clearance required for door moving 400 mm 500 mm
12 HANSHIN
Cycle Graph
It has 5 kinds of basic cycle and 2 kinds of test cycle
program. The sterilization and dry time can be
reduced, and the sterility assurance level can be
achieved by performance of the vacuum system.
Especially the liquid cycle program of the basic cycle
programs has a unique ability which can solve the
problems caused when sterilizing the culture medium
or the liquids with a small sterilizer at the clinical
examination laboratory.
Cycle No.1 Wrapped Cycle No.2 Wrapped
Appliance Table
AT-550
HANSHIN 13
Digital LED Display Type Steam Sterilizer
B-Class Vacuum Drying
BD series
Control Box
Operating Panel :
[TEMP./ PRESSURE] LED displays the actual temperature and pressure inside chamber in turn during
executing a cycle, [TIME] LED displays the remaining time of each phase. The pressing keys that have
the functions such as parameter value change, cursor move, cycle select, cycle START/STOP are
equipped on the panel for operating and controlling the sterilizer effectively.
It displays the present temperature to one decimal place for precise temperature control.
Cycle Monitor :
The indicators show each phase of executing cycle
such as condition, sterilize, vent, dry and completion in
sequence according to the cycle proceeding, also the BIXOLON Panel Printer
water level in reservoir and the state of overheating the Model : SPP-100LF/HSM
heater. Print Method : Thermal Line Printing
Dot density : 203dpi x 406 dpi
Panel Printer (Optional) : Printing Speed : 70 mm/sec
The panel printer prints out the cycle performance Paper Roll : 58 mm width,
record for analyzing of sterilization results and securing 40 mm diameter
the traceability afterwards.
Vacuumclave
HS-2519BD HS-2321BD
14 HANSHIN
B Class Steam Sterilizer
Pre-vacuum Air Removal & Vacuum Drying
Air Filter :
The bacteria-retentive filter which can filter out
99.999% (conform to EN 13060) of 0.3 particles
filters outside air supplied into the chamber during
the vent and drying phase. It prevents sterilized items
from a recontamination by bacteria in the air.
HS-3041BD
HANSHIN 15
Digital LED Display Type Steam Sterilizer
Vacuumclave
HS-2519BD/ HS-2321BD
HS-3041BD
These sterilizers apply the saturated steam generated from water by heater in the
chamber to sterilize, and are economical B-class(EU standard) sterilizer which
maximizes the performance of sterilization and dry after sterilization by removing air
from the chamber and loads enough by adopting the pre-vacuum process.
The panel printer(optional item) can be equipped to print out the cycle performance
record for securing the traceability afterwards.
HS-2519BD
HS-2321BD
HS-3041BD
Cycle Program
Items Basic Cycle Program Test Cycle Program
Cycle No. 1 2 3 4 5 Bowie-Dick / Helix Vacuum Leak
Load Type Unwrapped Wrapped Unwrapped Flash Liquid Test Pack / PCD N/A
Exposure Temperature 134 134 121 134 121 134
Exposure Time 5min 15min 20min 5min 30min 3.5min Dwell: 5min
Dry Time 20min 25min 20min 3min - - T e s t : 10min
Cooling Time - - - - 60min -
Self-Diagnosis
The self-diagnosis program detects the following 10 cases of operating error during cycle processing and aborts the cycle
automatically. The error code is displayed on the LED display with warning alarm.
16 HANSHIN
Cycle Graph
These sterilizers have 5 kinds of basic cycle program
for the wrapped or unwrapped medical instruments and
the products of synthetic resin, rubber, glass, textile,
liquid load in the glass container, and 2 kinds of
function test cycle. The sterilization and dry time can
be reduced and the sterility assurance level can be
fully achieved by powerful performance of the air
removal system adopted. Moreover, it has a perfect
sterilizing ability for “the Hollow Load A”.
Cycle No.1 Unwrapped Cycle No.2 Wrapped
HANSHIN 17
Touch Screen LCD Type Steam Sterilizer
Vacuum-Hollow & Vacuumclave
BTJ/BT series
Operating and Controlling the sterilizer by One Touching on the touch screen monitor !
Web Control Network Monitoring System composed of LAN, DB Server, Client !
Main Window
Vacuum-Hollow
HS-2519BTJ HS-3241BTJ
18 HANSHIN
B Class Steam Sterilizer
Pre-vacuum Air Removal & Vacuum Drying
Control System :
CTL-60TS Functions
Program selection
Maintenance screen
System error management
Cycle parameters change
Cycle history management
Cycle process monitoring in real time
System message guidance
Display of actual temperature and
pressure of processing
Display of door status
Data storage by SQL, DB (RTC back-up)
Menu Selection Display
Networking by LAN and USB
Ubiquitous Sterilizer
Web Control Network Monitoring System
Vacuumclave
HS-2321BT HS-3041BT
HANSHIN 19
Touch Screen LCD Type Steam Sterilizer
VACUUM-HOLLOW
HS-2519BTJ / HS-3241BTJ
These sterilizers achieve the best sterilizing performance by minimizing the deviation of
chamber temperature because cylindrical chamber is surrounded by jacket where the saturated
vapor is generated by emerging heater and over the set sterilization temperature is maintained
through a cycle, and also drying performance is excellent by a reason of flowing the dry saturate
vapor generated from the jacket into the chamber.
HS-2519BTJ
HS-3241BTJ
Cycle Program
Items Basic Cycle Program Test Cycle Program
P7 P8
Cycle No. P1 P2 P3 P4 P5 P6
Bowie-Dick / Helix Vacuum Leak
Load Type Wrapped Unwrapped Liquid Test Pack / PCD N/A
Exposure Temperature 134 121 134 134 121 121 134
Exposure Time 5min 15min 10min 5min 15min 30min 3.5min Dwell: 5min
Dry Time 15min 30min 15min 10min 15min - 5min T e s t : 10min
Cooling Time - - - - - 60min -
Self-Diagnosis
The self-diagnosis program detects the following 12 cases of operating error during cycle processing and aborts the cycle
automatically. The error code is displayed on the touch screen monitor.
20 HANSHIN
Cycle Graph
These sterilizers have 6 kinds of basic cycle program
for wrapped or unwrapped medical instruments, the
product of synthetic resin, rubber, glass, textile and
liquid in the glass container, 2 kinds of test cycle and
the self-diagnosis and warning program, furthermore
it is prepared for users to set 54 cycle programs at
their pleasure for performing sterilization in any
condition.
Appliance Table
AT-650
HANSHIN 21
Touch Screen LCD Type Steam Sterilizer
Vacuumclave
HS-2321BT / HS-3041BT
Usable space in the chamber is wide and loading of various items to be sterilized is easy due to
adopt rectangular chamber, and the total cycle time could be reduced by generating the steam
for sterilizing in the chamber directly.
HS-2321BT
HS-3041BT
Cycle Program
Items Basic Cycle Program Test Cycle Program
P7 P8
Cycle No. P1 P2 P3 P4 P5 P6
Bowie-Dick / Helix Vacuum Leak
Load Type Wrapped Unwrapped Liquid Test Pack / PCD N/A
Exposure Temperature 134 121 134 134 121 121 134
Exposure Time 5min 15min 10min 5min 15min 30min 3.5min Dwell: 5min
Dry Time 30min 30min 30min 30min 30min - 5min T e s t : 10min
Cooling Time - - - - - 60min -
Installation Information
Model HS-2321BT HS-3041BT
Overall dimensions of sterilizer (Net weight) W516 x D718 x H443 mm (57kg) W616 x D797 x H503 mm (82kg)
Appliance Table of the sterilizer (Net weight) W590 x D660 x H821 mm (16kg) W690 x D760 x H821 mm (22kg)
Dimension of usable space W1,190 x D1,660 x H1,526 mm W1,290 x D1,860 x H1,610 mm
Load per support area (N/m 2) when the Reservoir fill water: 4.2kg Reservoir fill water: 4.2kg
reservoir is filled with water in full level and Max. load: 1.2kg Max. load: 3.0kg
the chamber contains a maximum load. Water pressure test: 21.5kg Water pressure test: 40.5kg
Note; if the water pressure test is required, Load per support area: 1,973N/m2(max. load) Load per support area: 2,078N/m2(max. load)
e.g. by pressure vessel regulations, Load per support area: 2,484N/m2 Load per support area: 2,779N/m2
this weight should be considered. (water pressure test) (water pressure test)
Overall clearance required(left, right, front, rear, top side) each 300 mm each 300 mm
Clearance required for door moving 400 mm 500 mm
22 HANSHIN
Cycle Graph
These sterilizers have 6 kinds of basic cycle program
for wrapped or unwrapped medical instruments, the
product of synthetic resin, rubber, glass, textile and
liquid in the glass container, 2 kinds of test cycle and
the self-diagnosis and warning program, furthermore
it is prepared for users to set 54 cycle programs at
their pleasure for performing sterilization in any
condition.
Specification
Model HS-2321BT HS-3041BT
Overall Dimension W516 x D718 x H443 mm W616 x D797 x H503 mm
W 225 x D425 x H225 mm W300x D450 x H300 mm
Vol: 21.5 l , Material: STS 316L Vol: 40.5 l, Material: STS 316L
Chamber
Max. Working Pressure: 2.40bar, Min. Working Pressure: -1.00bar
Max. Working Temperature: 138.0 , Test Pressure: 5.00bar
Reservoir W238 x D117 x H233 mm, Vol: 4.2 l (full water level)
Tray W216 x D405 x H44 mm, 2ea W291 x D432 x H44 mm, 2ea
Operating Temperature 121.0 ~ 135.0
Sterilizing Agent Saturated vapor of max. 2.10bar pressure
Air Removal Vacuum / Gravity
Power Source AC 230V, 50/ 60Hz
Power Consumption 2,100W 3,100W
Controls Microprocessor
Display Touch Screen Type Color TFT LCD, 7.0 inch, Resolution: 800 x 480, LED backlight
Printer Direct Thermal Printing, Printing Paper Roll: W58 x Ø40 mm
Net Weight 57kg 82kg
HANSHIN 23
Digital LED Display Type Steam Sterilizer
Vacuum Drying
VD series
Vacuum-Drying
Safety Valve :
It prevents a possible damage from excessive
pressure in the chamber.
RS-232C
Reservoir :
It contains a condensing coil, a steam trap
and a water level sensor in order to supply
and withdraw water used for the sterilization.
HS-1606VD
This small size and high speed steam sterilizer, which is convenient to locate, mobile and
capable of sterilizing medical instruments instantly any time, is a most useful equipment for all
kinds of medical institutions including plastic surgery, dental and oriental medical clinic.
Especially the vacuum drying system adopted can minimizes common wet pack problem
remarkably !
HIGH SPEED
6(Heating) + 3(Sterilizing) = 9 minutes OK!
Successive Sterilizing = 7 minutes OK!
Appliance Table
AT-470
Feature
1. This high speed steam sterilizer proceeds the sterilization within a few minutes very quickly.
2. User doesn’t need to open the door when drying phase due to its use of vacuum pump, hence moisture retained by
the fabric package shall not exceed 2% than original weight after drying.
3. In case of error occurs, the self-diagnosis function can detects six kinds of abnormality and deal with the problems
properly.
4. It protects operator with safety devices such as door lock system, safety valve, circuit breaker, overheat protection
device, etc.
5. It is sanitary and easy to maintain the equipment because of using anticorrosive materials.
6. The sterilizer is easy to operate due to simple structured, light and small.
7. It is most suitable product to sterilize a small amount of instrument instantly at various clinic and oriental medical
clinic.
26 HANSHIN
Cycle Graph
5 kinds of built-in cycle program according to loads
type allows of operating easy and convenient.
HANSHIN 27
Digital LED Display Type Steam Sterilizer
Vacuum Drying
HS-2519VD/ HS-2321VD
HS-3041VD
These models are the typical S class small size sterilizers for sterilizing the general medical
devices economically by gravity air removal method, and the dry performance has improved
highly by adopting the vacuum drying system.
HS-2519VD
HS-2321VD
HS-3041VD
Feature
1. If the door is not locked, the cycle would not start in any case. It has a door cover which enables to protect operator
from thermal hazards and open/close mechanism which enables to operate the door with ease.
The safety valve opens to protect the chamber from exceeding its rated pressure.
2. User doesn’t need to open the door when drying phase due to its use of vacuum pump, hence moisture retained by
the fabric package shall not exceed 2% than original weight after drying.
3. The front panel of the sterilizer has a display unit which shows the process of cycle such setting values as pressure,
temperature, time and the phase such as ready, water fill, heating, sterilize, vent, dry and complete.
Self-Diagnosis
The self-diagnosis program detects the following 6 cases of operating error
during cycle processing and aborts the cycle automatically. The error code
is displayed on the LED display with warning alarm.
28 HANSHIN
Cycle Graph
5 kinds of cycle program that is composed of frequently
using typical sterilization parameters are embedded in the
controls of sterilizer. Therefore operator can select a
proper cycle conveniently for sterilizing a load and change
the parameters of program easily according to the
sterilizing condition. In case of the liquid cycle, the
innovative method, that the residual steam after
sterilization would not exhaust but cool down and
condense into water naturally, has been used which
enables to prevent liquid from boiling up or breaking the
Cycle No.1 Unwrapped Cycle No.2 Wrapped
bottle. In addition, the redrying cycle program is embedded
for drying function only.
Specification
Model HS-2519VD HS-2321VD HS-3041VD
Overall Dimension W483 x D607 x H403 mm W483 x D632 x H403 mm W581 x D702x H485 mm
Ø254 x L375 mm, W225 x D425 x H225 mm, W300 x D450 x H300 mm,
Vol: 19.5 l , Material: STS 316L Vol: 21.5 l , Material: STS 316L Vol: 40.5 l , Material: STS 316L
Chamber
Max. Working Pressure: 2.40bar, Min. Working Pressure: -1.00bar
Max. Working Temperature: 138.0 , Test Pressure: 5.00bar
Reservoir W238 x D117 x H233 mm, vol: 4.2 l (full water level)
Tray W184 x D340 x H18 mm, 4ea W216 x D405 x H44 mm, 2ea W291 x D432 x H44 mm, 2ea
Operating Temperature 121.0 ~ 135.0
Sterilizing Agent Saturated vapor of max. 2.10bar pressure
Air Removal Vacuum / Gravity
Vacuum Pump Flow Rate: 20 l /min Flow Rate: 30 l /min
Power Source AC 230V, 50/ 60Hz
Power Consumption 1,600W 1,600W 2,000W
Controls Microprocessor
Display LED Display
Printer(Optional) Exterior Type, Direct Thermal Printing, Roll Paper: W58 x Ø60 mm
Net Weight 40kg 55kg 77kg
HANSHIN 29
Digital LED Display Type Steam Sterilizer
Vacuum Drying
HS-3460VD
This sterilizer has a practical sized chamber and is very effective to sterilize a bigger loads or
more loads. Vacuum drying system minimizes the wet pack problem after completion of
sterilization.
HS-3460VD
Feature
1. User doesn’t need to open the door when drying phase due to its use of vacuum pump, hence moisture retained by
the fabric package shall not exceed 2% than original weight after drying.
2. Steam generator is separated from the chamber that prevents any possible damage of sterilizing goods might be
generated by the heater. Also it is effectively manageable that prevents any accidents might be occurred by the
user’s carelessness.
3. If the door is not locked, the cycle would not start in any case. It has a door cover which enables to protect operator
from thermal hazards and open/close mechanism which enables to operate the door with ease. The safety valve
opens to protect the chamber from exceeding its rated pressure.
4. The front panel of the sterilizer has a display unit which shows the process of cycle such setting values as pressure,
temperature, time and the phase such as ready, water fill, heating, sterilize, vent, dry and complete.
Self-Diagnosis
The self-diagnosis program detects the following 6 cases of operating error during cycle processing and aborts the
cycle automatically. The error code is displayed on the LED display with warning alarm.
30 HANSHIN
Cycle Graph
5 kinds of cycle program that is composed of frequently
using typical sterilization parameters are embedded in the
controls of sterilizer. Therefore operator can select a
proper cycle conveniently for sterilizing a load and change
the parameters of program easily according to the
sterilizing condition. In case of the liquid cycle, the
innovative method, that the residual steam after
sterilization would not exhaust but cool down and
condense into water naturally, has been used which
enables to prevent liquid from boiling up or breaking the
Cycle No.1 Unwrapped Cycle No.2 Wrapped
bottle. In addition, the redrying cycle program is embedded
for drying function only.
Specification
Model HS-3460VD
Overall Dimension W632 x D955 x H1,246 mm
Ø340 x L723 mm,
Vol: 60.0 l , Material: STS 316L
Chamber
Max. Working Pressure: 2.40bar, Min. Working Pressure: -1.00bar
Max. Working Temperature: 138.0 , Test Pressure: 5.00bar
Reservoir W238 x D117 x H233 mm, Vol: 4.2 l (full water level)
Loading Device Shelves: W236 x D635 mm 1ea, W300 x D635 mm 1ea
Operating Temperature 121.0 ~ 135.0
Sterilizing Agent Saturated vapor of max. 2.10bar pressure
Air Removal Vacuum / Gravity
Vacuum Pump Flow Rate: 40 l /min
Power Source AC 230V, 50/ 60Hz
Power Consumption 2,950W
Controls Microprocessor
Display LED Display
Printer(Optional) Exterior Type, Direct Thermal Printing, Roll Paper: W58 x Ø60 mm
Net Weight 152kg
HANSHIN 31
Digital LED Display Type Steam Sterilizer
Vacuum Drying
HS-60VD
Basket
Feature
1. Liquid and Retort(optional function) sterilization require a special condition as compared with other
sterilization. So, this sterilizer adopted the liquid cycle and retort cycle(optional) program with dual
temperature sensor(chamber and liquid sensor) which controls the sterilization temperature(121.0 ) and
exhaust temperature(80.0 ) of the liquid contained bottle and retort pouch. This special cycle enables to
prevent the liquid and retort pouch load from boiling over or bursting.
2. User doesn’t need to open the door when drying phase due to its use of vacuum pump, hence moisture retained by
the fabric package shall not exceed 2% than original weight after drying.
3. This sterilizer, adopting vertical chamber, may enlarge its capacity more than tabletop sterilizer. It may be used
conveniently even at narrow place for featuring large capacity.
4. It can process most safely culture medium or the glassware in the clinical examination or the laboratory of the
research institute; especially, it is useful when processing the liquids contained in a large glass bottle.
32 HANSHIN
Cycle Graph
5 kinds of cycle program that is composed of frequently
using typical sterilization parameters are embedded in the
controls of sterilizer. Therefore operator can select a
proper cycle conveniently for sterilizing a load and change
the parameters of program easily according to the
sterilizing condition.
Furthermore this sterilizer has an exclusive cycle
program for Liquid and Retort (optional) loads
because they require a special condition as compared
with other sterilization.
Cycle No.1 Unwrapped Cycle No.2 Wrapped
Specification
Model HS-60VD
Overall Dimension W575 x D531 x H1,080 mm
Ø340 x L723 mm,
Vol: 60.0 l , Material: STS 316L
Chamber
Max. Working Pressure: 2.40bar, Min. Working Pressure: -1.00bar
Max. Working Temperature: 138.0 , Test Pressure: 5.00bar
Reservoir W238 x D117 x H233 mm, Vol: 4.2 l (full water level)
Loading Device Basket: Ø300 x H310 mm, 2ea (Optional Type: Wire net basket, Ø300 x H195 mm, 3ea)
Operating Temperature 121.0 ~ 135.0
Sterilizing Agent Saturated vapor of max. 2.10bar pressure
Air Removal Vacuum / Gravity
Vacuum Pump Flow Rate: 40 l /min
Power Source AC 230V, 50/ 60Hz
Power Consumption 2,950W
Controls Microprocessor
Display LED Display
Printer(Optional) Exterior Type, Thermal Printing Type, Roll Paper: W58 x Ø60 mm
Net Weight 108kg
HANSHIN 33
Cutting & Sealing Machine for Sterilizing Bag
HCS-400
Cut and Seal the Roll Pouch for sterilizing with One Machine !!
Using the special designed machine for cutting and sealing the
roll pouch is recommended because the sterilized items may be
contaminated if the pouch is damaged while sterilizing or
conserving. This machine cuts and seals the sterilizing pouch
roll in one unit, therefore it is convenient and economical due to
require less space for working.
HCS-400
1. The entire processing is controlled automatically and displayed digitally on the LED display by a microprocessor.
2. If the cutting length and quantity are already set in the machine, the roll pouch is attracted to the pouch inlet
automatically and the set quantities of pouch that are sealed bottom side are produced after cutting in the set
length.
3. The pouch contained the items to be sterilized is sealed automatically if the upper side of pouch is inserted in the
sealing inlet, and sealing can be done manually by connecting the foot switch.
4. The set sealing temperature is maintained constantly by the PID control.
5. The appliance table with drawers for collecting the cut pouches and roll stand with multi shelf are provided in option.
34 HANSHIN
Error Warning
The error code is displayed on the LED display accompanying
an audible alarm in case of occurring an error during operating.
Specification
Model HCS- 400
Width of Roll: 50 ~ 400 mm,
Applied
Diameter of Roll: max. Ø250 mm,
Roll Pouch
Diameter of Paper Tube: Ø50 ~ 75 mm
Sealing Temp.
110 ~ 230
Range
HANSHIN 35