0% found this document useful (0 votes)
355 views2 pages

Assessment Oracle SPARC M5-32 Server Overview (WBT)

The document provides information about the configuration and components of an Oracle SPARC M5-32 server. Some key points: - A Bounded Dynamic Domain on an M5-32 server can have up to 8 CPUs and is still functional if it loses a Service Status Board. - The server has 2 clock boards, 2 I/O boards, 4 EMS modules, 16 PCI slots, and 8 hard drives/SSDs per I/O Unit. - It can support up to 4 Dynamic Domains, 512 Logical Domains, and each Service Processor Proxy can manage up to 4 CPUs. - With a maximum configuration of 192 cores across 4 Compute Memory Units, 32GB or

Uploaded by

Nazım Bilir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
355 views2 pages

Assessment Oracle SPARC M5-32 Server Overview (WBT)

The document provides information about the configuration and components of an Oracle SPARC M5-32 server. Some key points: - A Bounded Dynamic Domain on an M5-32 server can have up to 8 CPUs and is still functional if it loses a Service Status Board. - The server has 2 clock boards, 2 I/O boards, 4 EMS modules, 16 PCI slots, and 8 hard drives/SSDs per I/O Unit. - It can support up to 4 Dynamic Domains, 512 Logical Domains, and each Service Processor Proxy can manage up to 4 CPUs. - With a maximum configuration of 192 cores across 4 Compute Memory Units, 32GB or

Uploaded by

Nazım Bilir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 2

1.

Select the two statements that are true for a Bounded Dynamic Domain
configured on the SPARC M5-32 server.
Both Bounded Dynamic Domain and Dynamic Domains are impacted by loss of SSBs. (*)

2. Select the three options that are true for Clock Boards in the SPARC M5-32
server.
One clock board is redundant for failover (*)
Two Clock Boards (*)
One clock board is active (*)

Select the statement that is true for an IOU�s components


Two I/O boards, four EMS and sixteen PCI slots and eight HDDs/SSDs. (*)

There are two types of Dynamic Domains. Select the three statements that are true.
The System Administrator sets the attribute of the Dynamic Domain by setting the
variable expandable to either true or false. (*)
A Bounded Dynamic Domain (or Bounded PDom) is limited to eight SPARC M5 processors
in a single Domain Configuration Unit (DCU). (*)
A regular Dynamic Domain (or PDom) can be expanded beyond eight SPARC M5
processors. (*)

Select the three statements that apply to each SPP in the SPARC M5-32 server.
Monitors 8 fans (*)
Manages rKVMS activity (*)
Manages a maximum of 8 CPUs (or 4 CMUs) (*)

6. There can be _______Dynamic Domains (Physical Domains or PDoms) in the M5-32


Server. Select the statement that fills in the blank.
up to 4 (*)

7. Select three statements that apply to the SPARC M5-32 server.


It uses four SPPs. (*)
1 SPP is chosen as the "Golden SPP". (*)
Audit logs are forwarded from the SPP to Main-SP. (*)

8. Oracle ILOM on the SPARC M5-32 server has a set of extensions to support
enterprise features. Select the response that is true.
Physical Domains, Service Processor Proxies and redundant Service Processors. (*)

9. Select the statement that is true regarding the SPARC M5-32 server Bixby
ASICs.
Each group of six Bixby ASICs can have a loss of one SSB and the SPARC M5-32 server
can run in a degraded mode of five and the Coherency Directory is still available.
(*)

10. The SPARC M5-32 server comes configured with _________ PDOM(s). Select the
number that is true.
1 (*)

11. Select the two statements the apply to fans in the SPARC M5-32 server.
If there is an issue with a fan, the SPP informs the SP of any cooling issues and
the SP adjusts the fans if needed. (*)
If the fans are not working for a CMU, there will be no airflow so the CMU will be
shutdown. (*)

12. What is the maximum number of Logical Domains that can be supported in a
SPARC M5-32 server? Select the correct number.
512 (*)

13. The SPARC M5-32 server is designed specifically for virtualization. Select
the statement that is true.
The SPARC M5-32 server provides three SPARC virtualization technologies: Dynamic
Domains, Logical Domains, and Solaris Zones. (*)

14. Select the statement that is true.


Two CMUs or four CMUs, one SPP, one IOU and eight fans. (*)

15. The SPARC M5-32 server using its maximum CPU capacity has a total of ____
cores. Select the valid configuration.
192 (*)

16. How many SP Proxies are supported by a Service Processor (SP)? Select the
correct number.
4 (*)

17. Select the three components of the SPARC M5 processor that contribute to its
high throughput design.
L3 48MB shared cache (*)
Up to 8 threads per core (*)
6 S3 cores per CMP (*)

18. What size DIMMs are supported in the SPARC M5-32 server? Select all the sizes
that apply.
32 GB (*)
16 GB (*)

19. Select the configuration that is not valid for a SPARC M5-32 server.
Four DCUs cannot be configured as one Dynamic Domain. (*)

20. Select the three RAS features that apply to the SPARC M5-32 server.
Service Processor automatic failover (*)
Memory with extended ECC (*)
Hot-plug disk drives (*)