0% found this document useful (0 votes)
188 views1 page

FC' FC .45fc' Es Ec 4730 FC' N Es/Ec K N/ (N+FS/FC) J 1 - k/3

This document provides design details and calculations for a double reinforced concrete cantilever beam with a negative moment at its end. It includes material properties, load calculations, moment calculations, reinforcement sizing, shear calculations, and reinforcement spacing. The beam is designed with tension reinforcement of 3 bars of 16mm diameter each and compression reinforcement of 2 bars of 12mm diameter each. Shear reinforcement is determined to not be required.

Uploaded by

KULOT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views1 page

FC' FC .45fc' Es Ec 4730 FC' N Es/Ec K N/ (N+FS/FC) J 1 - k/3

This document provides design details and calculations for a double reinforced concrete cantilever beam with a negative moment at its end. It includes material properties, load calculations, moment calculations, reinforcement sizing, shear calculations, and reinforcement spacing. The beam is designed with tension reinforcement of 3 bars of 16mm diameter each and compression reinforcement of 2 bars of 12mm diameter each. Shear reinforcement is determined to not be required.

Uploaded by

KULOT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CB-1

DOUBLE REINFORCED CANTILEVER BEAM (WSD)


AT END - SPAN NEGATIVE MOMENT
DESIGN DATA FOR CONCRETE BEAMS:
13.79 17.2 20.7 mpa
ITEM fc' = 2,000.00 2,500.00 3,000.00 psi
fc = .45fc' 6.21 7.74 9.32
Es 200,000.00 200,000.00 200,000.00 mpa
Ec = 4730√fc' 17,564.80 19,616.67 21,520.20 mpa
n = Es/Ec 11.00 10.00 9.00
k = n/(n+fs/fc) 0.2255 0.2482 0.2634
j = 1 - k/3 0.92 0.92 0.91
Given: fc': 3,000.00 psi Span L: 1.2 meters
fc = 1,350.00 psi Beam Section:
9.308 mpa b 250 mm
fs = 34,000.00 psi d 400 mm
234.43 mpa Slab Thickness: 0.125 meters
Concrete Covering: Top = 40 Slab Width : 4 meters
Bottom = 40 Wall Ht. : 3 meters
Wall Thk.: 0.15 meters
DEADLOAD:
BEAM : 2.354 Kn / m
1/2L SLAB : 5.911 Kn / m
WALL : 5.297 Kn / m
SIESMIC: 1.338 Kn / m
LIVELOAD: 1.94 7.76 Kn / m
TOTAL LOAD: W = 22.660 Kn / m

DESIGN MOMENT: Md = WL^2/2 16.315 Kn - m

COMPUTING FOR M1 = fckjbd^2/2 36.23 Kn - m

As1 = M1/fsjd 470.66 sq.mm.

IF: M1 > Md: THEREFORE: ANALYZE SINGLE REINFORCE BEAM

COMPUTING FOR M2 = Md - M1 (19.92) Kn - m

As2 = M2/fs(d-d') (236.01) sq.mm.


TOTAL As = As1 + As2 234.65 sq.mm.

COMPUTE OF As':

WHERE: fs' = 2fs(kd-d')/(d-kd)


fs' = 96.94 Mpa
IF: fs' < fs USE: COMPUTED fs'
As' = M2/fs'(d-d') (642.05) sq.mm.

TRY:
No. of Bars Bar Diameter Unit Area Total Area
Tension 3.00 16 mm 201.06 sq.mm. 603.19 603.19 OK, SAFE !!!!
- mm 0.00 sq.mm. -
Compression 2.00 12 mm 113.10 sq.mm. 226.20 226.20 OK, SAFE !!!!
mm 0.00 sq.mm. -

CHECK FOR SHEAR:

V = wL-wd 19,034.73 Newton

v = V/bd 0.21 Mpa


Allowable va: va =.09*sqrt(f'c) 0.41 Mpa

va>v THEREFORE: WEB REINFORCEMENT NOT REQUIRED

10 mm Area = 78.54 sq.mm.

v' = v - va (0.20) Mpa

SPACING, S = 2Avfv/v'b (744.54) mm

ACI CODE: MAX. SPACING, Sm = 200 mm

IF:S<Sm:COMPUTED SPACING: S -744.54 mm