0% found this document useful (0 votes)
403 views3 pages

LOADINGS

The document outlines minimum design dead loads and live loads for various areas of a building with multiple floors. It provides load values in kPa for ceiling materials, floor fill, floor finishes, wall coverings, and partitions for restaurant/dining, restrooms, hotel rooms, hallways, and the roof deck on the second, third and fourth floors. It also specifies the superimposed dead load and live load for each area. Elevator loads are listed separately for the second, third and fourth floors.

Uploaded by

Joanne Dawang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
403 views3 pages

LOADINGS

The document outlines minimum design dead loads and live loads for various areas of a building with multiple floors. It provides load values in kPa for ceiling materials, floor fill, floor finishes, wall coverings, and partitions for restaurant/dining, restrooms, hotel rooms, hallways, and the roof deck on the second, third and fourth floors. It also specifies the superimposed dead load and live load for each area. Elevator loads are listed separately for the second, third and fourth floors.

Uploaded by

Joanne Dawang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Dawang, Joanne S.

MINIMUM DESIGN DEAD LOADS AND LIVE LOADS

@Second Floor Load (kPa)


*Restaurant (Dining and Kitchen)
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Floor Fill – stone concrete (per mm) 0.023
c. Floor Finish – ceramic or quarry tile (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.513
Live Load 4.8

*Restrooms
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Waterproofing – liquid, applied 0.05
c. Floor Fill – stone concrete (per mm) 0.023
d. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
e. Wall Coverings – cement tile 0.77
f. Partition – wood studs, 13mm gypsum board each side 0.38
Superimposed Dead Load (SDL) 2.713
Live Load 2.4

@Third Floor
*Rooms (Hotel Rooms)
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Waterproofing – liquid, applied 0.05
c. Floor Fill – stone concrete (per mm) 0.023
d. Floor Finish – ceramic or quarry tile (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.563
Live Load 1.9

*Restrooms
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Waterproofing – liquid, applied 0.05
c. Floor Fill – stone concrete (per mm) 0.023
d. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
Dawang, Joanne S.

Load (kPa)
e. Wall Coverings – cement tile 0.77
f. Partition – wood studs, 13mm gypsum board each side 0.38
Superimposed Dead Load (SDL) 2.713
Live Load 2.4

*Hallway or Corridor

a. Ceiling – suspended metal lath and cement plaster 0.72


b. Floor Fill – stone concrete (per mm) 0.023
c. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.513
Live Load 3.9

@Fourth Floor
*Rooms (Hotel Rooms)
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Waterproofing – liquid, applied 0.05
c. Floor Fill – stone concrete (per mm) 0.023
d. Floor Finish – ceramic or quarry tile (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.563
Live Load 1.9

*Restrooms
a. Ceiling – suspended metal lath and cement plaster 0.72
b. Waterproofing – liquid, applied 0.05
c. Floor Fill – stone concrete (per mm) 0.023
d. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
e. Wall Coverings – cement tile 0.77
f. Partition – wood studs, 13mm gypsum board each side 0.38
Superimposed Dead Load (SDL) 2.713
Live Load 2.4
Dawang, Joanne S.

Load (kPa)
*Hallway or Corridor

a. Ceiling – suspended metal lath and cement plaster 0.72


b. Floor Fill – stone concrete (per mm) 0.023
c. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.513
Live Load 3.9

@Roof Deck

a. Waterproofing – bituminous, gravel-covered 0.26

b. Floor Fill – stone concrete (per mm) 0.023


c. Floor Finish – ceramic or quarry tiles (20mm) on 13mm mortar bed 0.77
Superimposed Dead Load (SDL) 1.053
Live Load 1.9

@Other Loads
a. Elevator (per floor level)
DL + LL = 2*total load
@Second Floor
Total Load 22.852
@Third and Fourth Floors
Total Load 27.978

END