Catalogo Valvulas Cartucho Oil Control

Download as pdf or txt
Download as pdf or txt
You are on page 1of 127

Cartridge Program - Oil Control

The Drive & Control Company

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
INDEX

General Information 03

Mechanical Data 23

Solenoid Data 26

Pressure Control Valve 32

Special Valves 42

Check Valves 44

Counterbalance Valves 45

Flow Control Valves 59

Logic Elements 69

Directional Valves, Mechanically Operated 75

Shuttle Valves 78

Solenoid Valves 80

Coils 101

Manifolds 103

Cavities 116

Prefered Itens 126

Cartridge Valves - RC X BROC 127

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Hydraulic valves RE 64 020-B1/08.05

for mobile applications

General Information

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
What you need to know about these Operating Instructions
These Operating Instructions apply to Rexroth hydraulic valves for mobile applications and consist of the following
three parts.

Part I General Information RE 64 020-B1

Part II Product-specific Instructions

Part III Technical Datasheet

If you do not have all three parts, please request the missing part from Bosch Rexroth AG.
Only if all the information contained in all parts of the three-part Operating Instructions is observed
can safe operation of the Rexroth hydraulic valve be ensured.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Contents

1 General 4
1.1 Scope of application of these Operating Instructions 4
1.2 To assist your understanding of these Operating Instructions 4
1.3 Further important and applicable documents 4

2 Responsibilities 5
2.1 Liability and warranty 5
2.2 Responsibilities of the operator/user 5

3 Important basic safety instructions 6


3.1 Proper use 6
3.2 Improper use 7
3.3 Requirements for personnel, duty of care 7
3.4 Ancillary dangers and protective measures 9
3.5 Disposal 10

4 Pressure fluids 11
4.1 General information on pressure fluids 11
4.2 Malfunctions due to contamination of pressure fluid 11
4.3 Topping up / refilling 12

5 Storage and longer standstills 13


5.1 Storage conditions 13
5.2 Corrosion protection 13
5.3 Ageing during storage and longer standstills 13

6 Assembly and bringing into first use 14


6.1 Before bringing into first use 14
6.2 Bringing into first use, subsequent bringing into use 16

7 Maintenance 18
7.1 Definitions of terms 18
7.2 Safety during maintenance tasks 19
7.3 Inspection and servicing 20
7.4 Repair 20

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
1 General
1.1 Scope of application of these Operating Instructions
These Operating Instructions apply to Rexroth control and regulating valves for mobile
control systems.
These Operating Instructions are intended for the use of the system manufacturer and the
designer as well as the operator.
The designer can be a person that is responsible for the design of a hydraulic system in
which Rexroth valves are used.

1.2 To assist your understanding of these Operating


Instructions
Cross-references are printed in italics.

DANGER This symbol of danger indicates high risk, danger of loss of life or of serious injury.

WARNING This symbol of danger indicates medium risk, injury and serious damage to property.

CAUTION This symbol of danger indicates slight risk and possible damage.

Important This symbol indicates additional information.

1.3 Further important and applicable documents


For system manufacturers and users, in addition to the Operating Instructions, the relevant
installation drawing issued by Bosch Rexroth AG shall apply.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
2 Responsibilities
2.1 Liability and warranty
Bosch Rexroth AG is not liable for damages that result from non-compliance with or
disregard of this user’s manual.
Any modification of the Rexroth valves beyond the extent described in these Operating
Instructions shall render the warranty and, if applicable, any further concessions granted,
null and void.
Bosch Rexroth AG shall only be liable if the scope of delivery was shown to be defective.
Bosch Rexroth AG shall not be liable if a deficiency occurs that involves parts having been
replaced by the customer with equivalent but not identical parts as specified by the
manufacturer.

2.2 Responsibilities of the operator/user


Users and operators of the Rexroth valves are responsible for the proper use of these valves.
Users and operators must ensure that the Rexroth valves are stored, used, operated and
maintained only in accordance with the proper use as defined in these Operating
Instructions.
Any maintenance tasks specified in these Operating Instructions must be carried out at the
specified intervals.

WARNING Mineral-oil-based pressure fluid is hazardous to health and water; it may also be
flammable.
It may only be used if the relevant safety datasheet from the manufacturer is
available and all the measures stipulated therein have been implemented.

Important The Operating Instructions supplied by Bosch Rexroth AG – in all its parts and with all
other relevant applicable documents – contain safety-related information that must be
included by the system manufacturer/user in the Operating Instructions to be written for the
final product.

A wide range of dangers can arise from the combined actions of the Rexroth valve and the
machine or system in which the valve is installed.
System manufacturers, users or operators must therefore ensure that the Rexroth valve is
only installed if it is suitable, without restrictions, for the proposed application at the
installation location.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3 Important basic safety instructions
3.1 Proper use
Rexroth valves have been designed and constructed for the control and regulation of energy
and signals using a flow of oil. The safety components integrated into the Rexroth valves
satisfy at least Safety Category 1 in accordance with EN 954-1.
However, only by carefully observing these Operating Instructions can accidents be pre-
vented and problem-free operation of your Rexroth valve be guaranteed.
Use the Rexroth valve only as described in these Operating Instructions and if it is stored,
installed, operated and maintained in accordance with the technical data, operating and
ambient conditions as defined in these Operating Instructions. The limiting values given in
Part III, Technical Datasheet must be observed.
Information on storage and longer standstills is given in 5 Storage and longer standstills.
Rexroth valves may only be operated if they are in perfect technical condition.
The Rexroth valve must be operated only with the pressure fluids intended for the purpose
specified in Part III, Technical Datasheet . Information on using the Rexroth valve with
different pressure fluids is available on request.
The Rexroth valve must be used only for the purpose specified in Part III, Technical
Datasheet. The connections, operating conditions and performance data defined in these
Operating Instructions must not be changed.

Important If you wish to use the Rexroth valve with connections, operating conditions and
performance data or for purposes other than those defined by Bosch Rexroth AG in these
Operating Instructions, you should contact Bosch Rexroth AG in advance. The Rexroth
valve must not be used with connections, operating conditions and performance data or for
purposes other than those defined in these Operating Instructions without the written
agreement of Bosch Rexroth AG.

Rexroth valves may only be converted within the scope given in Part II, Product-specific
Instructions.
During setting up or maintenance work, unless impractical, the safety devices fitted by
Bosch Rexroth AG must be present, properly installed and in full working order. They
must not be relocated, bypassed or rendered ineffective.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3.2 Improper use
Modifications and/or conversions of a Rexroth valve are only permissible within the scope
given in Part II, Product-specific Instructions.
Tamperproof lead seals installed by Bosch Rexroth AG shall not be removed or damaged
except when this is necessary in the course of maintenance tasks defined in the Operating
Instructions.
Rexroth valves for which these Operating Instructions apply shall not be used in potentially
explosive atmospheres. Special Rexroth valves are available that can be used in potentially
explosive atmospheres.
Pressure control valves without a type examination in accordance with the EU Pressure
Equipment Directive must not be used as safety valves in safety-related applications.
The nameplate must not be removed or painted over.

3.3 Requirements for personnel, duty of care


3.3.1 General requirements, qualifications
Rexroth valves must never be operated or maintained by persons under the influence of
alcohol, drugs or other medication which affect one’s ability to react.
Persons under the age of 18 who are currently receiving instruction or training or are working
under supervision may not work on Rexroth valves.
This does not apply to young persons of 16 or over if
− working on Rexroth valves is necessary in order for them to accomplish their training
objective
− their protection is guaranteed by the supervision of an experienced, competent person
and they are allowed to use only tools, materials and protective gear that preclude the
risk of injury.

Specialist personnel are those who, using their specialist training, knowledge and experience
as well as familiarity with the relevant conditions, can recognise possible dangers and under-
take the necessary measures to eliminate possible accidents.

3.3.2 Requirements for maintenance personnel


It may be necessary to carry out maintenance tasks on the Rexroth valve in order to keep it in
proper working order. For details please refer to Part II, Product-specific Instructions.
Maintenance tasks include inspection, servicing and repair of hydraulic and electrical comp-
onents. The personnel carrying out these various tasks must have certain minimum
qualifications.
For inspections of the external parts of hydraulic components, the personnel must fulfil the
following requirements:
− they must be instructed about the tasks,
− Specialist knowledge of hydraulics is not required.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
For maintenance of the hydraulic components, the personnel must fulfil the following
requirements:
− They have been instructed in the relevant activity.
− Specialist knowledge of hydraulics is required.

For maintenance of the Rexroth valves, the personnel must fulfil the following requirements:
− The personnel must be hydraulics experts instructed in the tasks as defined above.
− The personnel must be familiar with the function of the hydraulic system as a whole, from
subsystems to their interaction with the function of the machine as a whole.
− The personnel must be able to read hydraulic circuit diagrams, interpret individual func-
tions from their symbols and understand function diagrams.
− The personnel must possess knowledge of the function and construction of hydraulic
elements in general and of the Rexroth valves to be maintained in particular.
See also 7.4 Repair.

For work on the electrics, the following applies:


All work on electrical equipment may only be carried out by an authorised, qualified elec-
trician, or by instructed persons under the guidance and supervision of an authorised
qualified electrician, in accordance with the rules applicable to electrotechnical products.

For work on the software, the following applies:


Modifications of the software may only be carried out by bodies authorised to do so by
Bosch Rexroth AG.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3.4 Ancillary dangers and protective measures

DANGER

Danger zone Ancillary danger Protective measure(s), safety instructions

Connections and Risk of injury or loss of life from Depressurise the hydraulic system before starting
pressure lines (pipes sprayed pressure fluid under high maintenance work. Relieve any accumulators of
and hoses) pressure during maintenance work. pressure.
Rectify leaks immediately.

There is a health hazard if escaping Tanks installed above the valve being repaired must
pressure fluid comes into contact be emptied before work is started.
with the skin. This is a particular
risk if the tank is at a higher level
during repair work

Surfaces of comp- Risk of burning due to high surface Allow hydraulic parts to cool before commencing
onents and pressure temperatures maintenance work.
lines
Wear protective clothing.

Electrical Electric shock Work on electrical components only in the non-


components powered state.
Switch electrical connections off before assembly
and disassembly work starts.
All tasks that require product components to be
dismantled must be performed only within the
scope given in Part II, Product-specific Instructions.

Failure caused by excessive Shield the valve from the direct effect of high-
moisture entry following cleaning pressure water jets.
with a high-pressure cleaner

Handling pressure fluid without protection is hazardous to health.


Please observe the manufacturer's safety instructions and the relevant safety datasheets for
the pressure fluid that you are using.
Serious damage to health or death may result if pressure fluid enters the blood stream or is
swallowed. Contact a physician immediately if pressure fluid has entered the blood stream
or has been swallowed.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CAUTION Risk of environmental pollution

Danger zone Ancillary danger Protective measure(s), safety instructions

Connections and Water or ground pollution due to Use a collecting trough.


pressure lines (pipes leakage
Rectify leaks immediately.
and hoses)

Important Also see 2.2 Responsibilities of the operator/user.

3.5 Disposal
Completely empty valve and dispose as scrap metal.

Important To completely empty means that the valve must be properly emptied so that no more
pressure fluid can drip out.
The valve does not need to be cleaned when it is completely empty.

Collect residual pressure fluid and dispose of it in accordance with the instructions given in
the safety datasheet of the pressure fluid.
Dispose of electronic products in accordance with the applicable regulations.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
4 Pressure fluids
4.1 General information on pressure fluids
The effectiveness of pressure fluid diminishes as it ages (undergoes chemical changes).
Acids and resinous residues form that may cause moving parts inside the valves to stick.
The following factors accelerate the ageing process:
− high temperatures
− oxygen in the pressure fluid
− air humidity
− water
− metallic catalysts
− high operating pressure
− contaminants.

Important Observe the following rules of thumb:


At pressure fluid temperatures > 70 °C, the rate of ageing doubles for every 10 °C.

Further information on mineral-oil-based pressure fluids, also concerning Rexroth valves,


can be found in our publications RE 90 220 Mineral-oil Based Pressure Fluids and
RE 90 220-1 Hydraulic Fluids on Mineral Oil Basis for Axial Piston Units.

4.2 Malfunctions due to contamination of pressure fluid


Contaminants of the pressure fluid lead to malfunctions, increased wear and a shorter
service life of the hydraulic product. This can have negative effects on the safety and
reliability of the hydraulic product.
Therefore the maintenance tasks specified in the Operating Instructions of the hydraulic
system shall be carried out at regular intervals and the utmost cleanliness is required during
work on the hydraulic product.
Contamination of the pressure fluid can be caused by:
− Wear during operation of the machine/system
(metallic and non-metallic abrasion)
− Leaks of the hydraulic product
− Contaminants introduced during servicing/repair
− The use of dirty (unfiltered) pressure fluid when the pressure fluid is changed.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
4.3 Topping up / refilling
When topping up / refilling your hydraulic system, make sure that you use pressure fluid of
the same sort and type and from the same manufacturer.
If the fluid is heavily contaminated or prematurely aged, then the system, including the tank
must be cleaned and flushed before refilling. New pressure fluid must always be filtered in
accordance with the required cleanliness class, as it does not normally meet the required
cleanliness class in the as-supplied state. Flush out lines and hoses before installation.
Use a filter unit to fill the pressure fluid tank. Ensure that the filter element is clean. Do not
remove the filter strainers from filler necks or the filter element from filters before filling the
pressure fluid tank.

Important The fineness of the filter shall correspond to the cleanliness class required by the overall
system and if possible be even finer. The filter unit used shall fulfil the requirements for
functional safety and service life.
If possible, fill the pressure fluid tank via a filling coupling, if possible using a filter in the
return line.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
5 Storage and longer standstills
5.1 Storage conditions
Store the Rexroth valve only in a dry, dust-free atmosphere that is free of corrosive agents
and vapours, has a low moisture content and no large variations in temperature.

5.2 Corrosion protection


Rexroth valves are tested with mineral oil in the factory. This oil protects sealed valves
against internal corrosion.
Unpainted valves or those that only have a galvanic coating are not protected against
corrosion.
Delays in bringing into use, long shipping and storage times or long periods of non-use can
lead to rust formation in Rexroth valves. Additional corrosion protection measures must be
implemented to prevent this.

5.3 Ageing during storage and longer standstills


Long storage times or long periods of non-use of Rexroth valves leads to damage of seals
and plastic parts.
External seals of valves that have been stored for more than 12 months must be checked for
damage before they are installed. They must be replaced, if necessary.
All externally acting seals must be replaced after a storage time or standstill period of
3 years. Seal sets can be ordered from Bosch Rexroth AG.
Every time the unit is brought into use, the valves must be checked that they are not leaking
to the outside, see 6 Assembly and bringing into first use. If there is a leakage, the seals
must be replaced.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
6 Assembly and bringing into first use
CAUTION Risk of injury and damage
Wear safety gloves to avoid being injured by sharp edges.
Assembling and bringing into (first) use shall only be done by an instructed,
authorised hydraulics expert who has the required specialist knowledge.

Pay attention to cleanliness:


− Do not use cleaning wool or cloths containing fibres for cleaning. Depending on the con-
dition of the system or machine, cleaning with fibre-free cloths may be sufficient. Use
suitable liquid cleaning agents to remove lubricants and other stronger contaminants.
Make sure that cleaning agent does not get into the hydraulic system.
− Use only sealing elements specified in Part III, Technical Datasheet.

6.1 Before bringing into first use


1. Check the delivery for completeness and transport damage.
2. Check whether the seals are present for all connections and that they are in a perfect
condition.
3. Check that the Operating Instructions for the Rexroth valve are present and complete.
Contact us if the Operating Instructions are incomplete.
4. If the valve is to be painted prior to assembly, then
¾before painting, protect all hydraulic connections from being covered in paint by fully
inserting plastic screw plugs
¾protect any fastening threads from being covered in paint by inserting a screw
¾carefully mask the flange surfaces of the valves as well as the subplates and end-
plates before painting to prevent dirt and paint from entering
¾mask plastic plugs of the electrical connections and make sure not to damage the
plugs in any way.
A removable foil has been applied to the nameplate in the factory to protect them during
painting.
When removing the plastic screw plugs, ensure that paint splinters do not get into the
valve.
5. Mount the Rexroth valve.
¾Use the intended seal for each hydraulic connection.
¾Mount and fit the pipes to the Rexroth valve so that they are free of strain.
¾Tighten the fastening bolts evenly with the specified tightening torque. Only fasten-
ing materials specified in the Operating Instructions are to be used.

6. Ensure that the interfaces of the system/machine and the installation conditions provide
for safe operation of the Rexroth valve. If in doubt, consult the people responsible for the
overall system / functional machine.
7. Based on the operating instructions for the system or machine in which the Rexroth valve
is to be installed, check whether bringing the hydraulic system into use could lead to
uncontrolled, dangerous movements. Where appropriate, take into account the hazard
analysis / risk assessment for the system or machine.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
8. Take the precautions appropriate to the anticipated dangers, e. g.:
¾Ensure that the cylinder piston rod can move out without danger.
¾Use a hoist or other lifting device to additionally secure lifted loads.

9. As part of bringing into (first) use, check whether the electric motors and valve solenoids
can be switched manually using the electrical controls of the system/machine. If they
cannot be switched manually or they can but with difficulty you must provide a remote
control (e. g. test boxes for Rexroth proportional valves) for the internal function test of
the hydraulic system.
10. Draw up a sequential program for bringing into (first) use and store it with the technical
documentation as an appendix to the Operating Instructions.
11. Divide the functional circuit diagram into separate mini-circuits that can each be started
up in succession.
12. Read the functional circuit diagram and seek clarification of any unclear text or diagrams.
More information on the functioning of subassemblies is given in the Technical
Datasheet.
13. Establish into which position valves are to be switched, or how valves are to be set.
14. Put up any necessary directional, prohibitive or informative signs and check whether the
meaning of these signs is explained in the Operating Instructions.
15. Follow this sequence for bringing into (first) use
− Pump circuit
− Parts of the control system: e. g. pressure cut-off and switchover, open centre,
pressure reduction, etc.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
6.2 Bringing into first use, subsequent bringing into use
¾Take suitable precautions when bringing into first use to maintain the required purity of
the pressure fluid.
− Make sure that the quality of the pressure fluid is not diminished by contaminants in
the system.
− Completely remove any oil residues left over from the factory test.
− Remove any gummed oil which may have formed due to incorrect storage.

¾Connect all connection lines in accordance with the installation instructions provided by
the manufacturer of the connectors.

DANGER Danger due to pressure fluid escaping with a high pressure.


Wear safety goggles and safety gloves!
Make sure that pipes and hoses are connected at all ports or that the ports are
sealed with screw plugs.
Carry out a special check to make sure that the union nuts and flanges are correctly
tightened at the pipe connections and flanges.

¾Set the pressure and flow control valves, pump regulator, signalling elements such as
pressure switches, limit switches and temperature regulators to the settings and values
defined in the sequential program (see 6.1 Before bringing into first use).

DANGER Dangers due to malfunctions


Do not change the settings of valves with a safety function, valves with a position
switch or valves with preset electronics.

¾Do not remove the lead seals. Damaged or removed lead seals indicate improper use of
the hydraulic product.
¾Bleed the hydraulics (valve, pump, motor, line, cylinder). Bleed the hydraulics lines to
consumers or measuring points at the highest point, if possible. Before bringing into use,
the valve must be filled with pressure fluid and the system in which the valve is installed
must be completely bled.

Important Details on bleeding can be found in the Operating Instructions of the respective system.

Important Details on fine-tuning can be found in the Operating Instructions of the respective system.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
¾Check the operating temperature after the machine has been running continuously for
several hours. Too high an operating temperature indicates that there are faults that need
to be analysed and rectified.
¾After bringing the machine into first use, have a sample of the pressure fluid analysed to
ensure that it achieves the required cleanliness class. Change the pressure fluid if the
required cleanliness class is not achieved. If the pressure fluid is not tested in the lab-
oratory after bringing the machine into first use: Change the pressure fluid.

Important Information on how to perform the function test and pressure test can be found in the
Operating Instructions of the respective system.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7 Maintenance
7.1 Definitions of terms
The term "Maintenance" as defined in DIN 31051 encompasses all measures to maintain
and restore the desired conditions and to determine and assess the actual condition of the
technical devices of a system.
These measures are divided into the following categories:
− Inspection (determining the actual condition)
− Servicing (maintaining the desired condition)
− Repair (restoring the desired condition).

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7.2 Safety during maintenance tasks
DANGER Dangers due to reduced safety during repair work
Experience has shown that the number of accidents is higher during repair work than
during normal operations. Therefore, in the interests of safety, please observe all the
following safety instructions at all times.
¾Regularly check any safety devices – if installed – for their correct functioning.
¾Perform all maintenance work properly, completely and within the stipulated
periods and make a record of the work.
¾Cordon off the maintenance zone at a sufficient distance before commencing
work.
¾Pay attention to cleanliness to avoid malfunctions caused by contamination.
¾Exercise extreme vigilance when operating the hydraulic product in maintenance
mode, which may in certain circumstances necessitate the temporary removal of
certain safety devices. Switch off the hydraulic system and secure it against being
unintentionally switched on again.
¾The set values of safety valves shall not be altered by the user. Any readjustment
shall be performed by authorised testing bodies only.
¾Wear safety goggles, safety gloves and safety shoes. Depressurise the hydraulic
product, relieve the pressure in any pressure accumulators.
¾Allow pressure lines and sections of the system which have to be opened to cool
down before commencing maintenance work.
¾Open with care any segments that have to remain under pressure.
¾Note that if check valves are located in the pressure lines above the pumps, the
hydraulic system may still be under pressure even after it has been disconnected
from the actual pressure supply. Advance all cylinders to their safe end position.
¾Lower all loads. Use an external support if it is not possible to lower a load. Never
perform any maintenance work on raised units without external support.
¾Switch off all pumps.
¾Mechanically support vertical cylinders so that they cannot descend.
¾Only new, interchangeable and tested components, replacement parts and
lubricants in original-equipment quality are approved for use/replacement.
¾For reasons of safety, the installation of untested components is strictly
prohibited.
¾Make sure that all safety devices are properly installed and have undergone a
function test before bringing the system (back) into use.
¾Remove all tools and materials needed for maintenance from the hydraulic
product after the work has been completed.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7.3 Inspection and servicing
The objective of inspection and servicing is
− to maintain all system functions along with the initial parameters of the system
− to ensure continual availability of the system
− to detect weak points
− to ensure that the system attains the required service life.

We strongly recommend the use of an inspection and servicing book, in which all work
specific to the system and the site, and all inspection and servicing intervals should be
defined and documented.

Important The product-specific inspection and servicing plan for the Rexroth valve can be found in
Part II, Product-specific Operating Instructions.

7.4 Repair
All repairs of Rexroth valves must be carried out only by workshops authorised by
Bosch Rexroth AG.

Bosch Rexroth AG © This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Robert-Bosch-Straße 2 reproduced or given to third parties without its consent.
71701 Schwieberdingen, Germany
The data specified above only serve to describe the product. No statements
Fax +49 (0) 7 11 / 811-1798
concerning a certain condition or suitability for a certain application can be
[email protected]
derived from our information. The given information does not release the user
www.boschrexroth.de
from the obligation of own judgement and verification. It must be remem-
bered that our products are subject to a natural process of wear and aging.

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA

HYDRAULIC FLUID
General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic
systems such as, for example:
- MINERAL OIL BASED HYDRAULIC FLUIDS HL
(DIN 51524 part 1)
- MINERAL OIL BASED HYDRAULIC FLUIDS HLP
(DIN 51524 part 2).
For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult BROC.
Viscosity class: according to ISO-DIN, it is expressed by the ISO-VG number which indicates the average
NLQHPDWLFYLVFRVLW\DWƒ& ƒ) ±PP2VRUFHQWLVWRNHV±F6W

Test conditions: the main performance curves and specifications shown in this catalogue are obtained using
mineral based fluid ISO VG 46, with a cleanliness class of 17/14 - 18/14 ISO 4406 (8-9 NAS 1638), at a
temperature of 30/40°C (86/104°F). More detailed technical characteristics are available at BROC.
Fluid temperature range: the valves are designed for fluids at a temperature between -30°C and +100°C (-22°F
and +212°F). For temperatures outside this range, consult BROC.
Internal leakage: most BROC valves have a leak proof seat design, but there are different families of valves
each providing a different level of sealing depending on the type and number of the poppets; the leakage features
of each valve type must be selected in order to suit the application.
The table A (pg. A-PD3) shows the AVERAGE LEAKAGE for various valve families; the readings are achieved in
the specified test conditions, and are measured in cm3/min or drops/min.
The ratio between them is:
1 cm3/min (0.06 in3/min) = 15y20 drops/min.
For pressure relief valves the leakage is indicated at re-seating conditions, identified as X% of pressure relief
setting.

CLEANLINESS (see table B, pg. A-PD3)


General information: the cause of malfunctions in hydraulic systems and components is often found to be
excessive fluid contamination. The hard contaminant particles in the fluid wear the hydraulic components and
prevent the poppets from re-seating, with consequent internal leakage and system inefficiency. For the correct
operation of BROC valves it is necessary to ensure a fluid cleanliness class at least 19/15 ISO-4406, or 10y11
NAS-1638, unless otherwise specified in the relevant technical sheet.
Filtration ratio (Ex): FKDUDFWHULVWLFRIHDFKW\SHRIILOWHULW¶VWKHUDWLREHWZHHQWKHQXPEHURISDUWLFOHVEHIRUHDQG
after the filter with diameter larger than X micron.
Absolute filtration rating (ISO 4572): the diameter X of the largest particles with Ex t 75.
Contamination class ISO 4406: expressed by two numbers respectively representing the number of particles
larger than 5 ȝm and larger than 15 ȝm contained in 1 ml of fluid.
Contamination class NAS 1638: expressed by one number representing the number of particles of different
size ranges contained in 100 ml of fluid.

Rev.0306 Page A-PD2

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA
TECHNICAL DATA

Rev.0605 Page A-PD3

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA

PRESSURE SETTING: BROC valves are supplied pre-set at the standard pressure setting shown by the
relevant catalog sheet. Whenever the application requires a re-adjustment, please ensure that the limits of the
indicated pressure range are never exceeded.

SEALING OF VALVE ADJUSTERS: plastic sealing caps are available for most cartridge valves.
The cartridges can be purchased Factory sealed.

INSTALLATION OF CARTRIDGE VALVES:


Procedure to be followed for correct installation of the cartridge valves in their cavities:
 ensure that seals and back-up rings are flawless and correctly installed;
 check that both the cartridge and the cavity are clean, without contamination;
 dip the cartridge in clean oil;
 insert the cartridge into the cavity and screw it in by hand, until you begin to compress the top o-ring
 tighten with a calibrated torque wrench up to the specifications shown in the catalogue.

STORAGE OF NEW VALVES:


the valves shall not be exposed to direct sun light nor to sources of heat or ozone (like electric motors running),
and should be stored in their original, protective wrapping at a temperature between -20°C and +50°C (-4°F and
+122°F).

Rev.0306 Page A-PD4

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
CONTINUOUS DUTY COILSCONTINUOUS
- ED 100% DUTY COILS - ED 100%

WORKING DUTY DIN VDE 0580 INLET VOLTAGE


The working duty ED of a coil is the ratio between To obtain correct operation and long life of coils it is
energized time ti and full cycle time tc where tc = ti + tr necessary that operating voltage fluctuations do not exceed
and tr = de-energized time. ± 10 % of nominal voltage.

ED = ( ti / tc ) Ã 100 %
HEAT INSULATION DIN VDE 0580
ALL COILS ARE RATED FOR ED = 100 % All COILS
PROVIDED THAT TEMPERATURE LIMIT OF THEIR
INSULATION CLASS IS NOT EXCEEDED. COMPLETE COIL CLASS H 365qF (180qC)
Copper wire 392qF (200qC)

PROTECTION DIN 40050 Part 9 - EN 60529


These are the maximum allowable absolute temperatures T
Protection class is designated by the letter IP followed by = TA + 'T where TA = ambient temperature and 'T
two digits: the first indicates protection against penetration = temperature rise due to operation.
of foreign solid bodies, the second against penetration of
For example, if TA = 104qF (40qC) we obtain 'Tmax =
water. Protection class doesn’t apply to explosion risks or
to conditions such as moisture, corrosive agents, mildew 239qF (115qC) if we have to comply with the limit of 311qF
etc. (155qC) and 'Tmax = 284qF (140qC) if we have to comply
with the limit of 365qF (180qC).
IP65 MEANS WATER PROTECTION AGAINST:
x LOW PRESSURE JETS
The temperature rise 'T is calculated from resistance at
Water at 43.5 psi (0.3 bar) pressure sprayed from a
ambient temperature and resistance at stabilized
distance of 8.2 - 9.8 ft (2.5 – 3 m) from every direction.
temperature, measured according to DIN VDE 0580:
Coils CANNOT BE PLUNGED INTO WATER OR REMAIN
UNDER WATER. x coil is mounted on a standard cartridge valve size 06
inserted in a standard steel manifold on a wooden
surface.
IP67 MEANS WATER PROTECTION AGAINST:
x coil is kept energized for 1 hour at nominal voltage, with
x 30 MINUTES IMMERSION AT 3.3 ft (1 m) DEPTH
ambient temperature TA = 68 - 77qF (20-25qC) and
natural ventilation.
IP69K MEANS WATER PROTECTION AGAINST:
x HIGH PRESSURE AND TEMPERATURE JETS CLASS H COILS ARE NOT RATED FOR CONTINUOUS
Water at 1160 - 1450 psi (80-100 bar) pressure and 167 - DUTY ED = 100 % IF AMBIENT TEMPERATURE
185°F (75-85°C) temperature sprayed from a distance of EXCEEDS THE VALUE Tx = 365 (180) - 'T qF (qC)
3.9 - 5.9 in (100 - 150 mm) from every direction. IN ANY CASE FREE HEAT EXCHANGE AND NATURAL
VENTILATION ARE NECESSARY FOR THE CORRECT
PROTECTION THERMAL SHOCK DUNK TEST OPERATION OF COILS.
This test, well known and commonly applied in the
construction, agricultural and mobile equipment markets, EXTERNAL TEMPERATURE of coils is not directly related
includes several steps : with 'T. After few minutes of continuous energization
1) Coil is continuously energized for 1 hour at nominal temperatures up to 176-212qF (80-100qC) can be reached,
voltage (ambient temperature 77°F (25°C)) or heated so care should be taken to avoid accidental contact of
for 2 hours in oven at 221°F (105°C) (coil not people with hot surfaces.
energized)
2) Coil is immediately immersed in water at 68 - 77°F (20 - AC SERVICE
25°C) for 30 minutes (minimum depth 11.8 in (300 mm)) All OIL CONTROL’s solenoid valves are designed to
3) Coil, when still wet, is tested for moisture ingression operate only with DC power supply. All windings are DC.
and dielectric breakdown with the “Hypot test”. Using AC service is possible using DIN 43650 connectors with
an instrument for testing dielectric strength, 500 VDC rectifier (see page 1.71.010).
is supplied between winding and external surface of
the coil and current leakage is measured. Current
leakage must not exceed 100 micro-amps
4) Complete cycle is repeated for 5 times minimum on a
sample of 10 coils minimum

All coils with DIN 43650 connector correctly mounted


have IP65 protection.
S8-356, S7 and S5 coils with integrated Deutsch DT04-
2P connector have IP69K protection and have passed
the thermal shock dunk test.
Rev.06.05 7.01.010.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA
TECHNICAL DATA
STANDARD MANUAL OVERRIDE
STANDARD MANUAL OVERRIDE OPTIONS
OPTIONS

SCREW-OUT KNOB STYLE


AVAILABLE ON FOLLOWING MODELS:
x 2 way 2 position pilot operated normally closed series 8A / 8I
x 2 way 2 position direct acting poppet style normally closed series 8I
x 2 way 2 position direct acting double lock normally open series 8I
x 3 way 2 position spool style series 8I / 7I
x 4 way 2 position spool style series 8I / 7I
OPERATION
To operate manual override, screw out the knob turning it counterclockwise.
To return to normal valve operation, turn the knob clockwise.
SCREW-IN STYLE AVAILABLE ON FOLLOWING MODELS:
x Proportional valves series 5A
OPERATION
To operate manual override, screw in the pin turning it clockwise with wrench.
To return to normal valve operation, turn the bolt counterclockwise.

PUSH STYLE AVAILABLE ON FOLLOWING MODELS:


x 2 way 2 position pilot operated normally open series 8A / 8I
x 2 way 2 position direct acting poppet style normally open series 8I
x 2 way 2 position direct acting double lock normally closed series 8I
OPERATION
To operate manual override, push and hold override button.
To return to normal valve operation, simply release the button.

AVAILABLE ON FOLLOWING MODELS:


x 2 way 2 position direct acting double lock normally closed series 7A
x 3 way 2 position direct acting poppet style series 7A
OPERATION
To operate manual override, push and hold override button with tool.
To return to normal valve operation, simply release the button.

PUSH AND TWIST STYLE AVAILABLE ON FOLLOWING MODELS:


x 2 way 2 position pilot operated normally open series 8A / 8I
x 2 way 2 position direct acting poppet style normally open series 8I
x 2 way 2 position direct acting double lock normally closed series 8I
OPERATION
To operate manual override button, turn clockwise and release.
To return to normal valve operation, push override button, turn counterclockwise and
release.

PUSH AND PULL STYLE AVAILABLE ON FOLLOWING MODELS:


x 4 way 3 position spool style series 8A / 7I
OPERATION
To operate manual override, push to override S2 coil or pull to override S1 coil and
hold override button.
To return to normal valve operation, simply release the button.

Rev. 06.05 7.01.020.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
SPECIAL MANUAL OVERRIDE OPTIONS
SPECIAL MANUAL OVERRIDE OPTIONS

PULL STYLE
CABLE HAND AVAILABLE ON FOLLOWING MODELS:
OPERATED OPERATED x 2 way 2 position pilot operated normally closed series 8A size 06
OPERATION
To operate manual override, pull and hold the knob. This override is not detented.
Force required to operate is approximately 11.2 lbs (50 N).
This override can also be remote operated by a cable fixed to the M8 thread. In this
case the spring may not provide enough force to overcome internal cable friction and
the user must provide an external means of returning the cable.

SAFETY AVAILABLE ON FOLLOWING MODELS:


PUSH STYLE
x 2 way 2 position pilot operated normally open series 8A / 8I
x 2 way 2 position direct acting poppet style normally open series 8I
x 2 way 2 position direct acting double lock normally closed series 8I
OPERATION
To operate manual override, screw out the knob protection after removing wire-
locking and push and hold override button.
To return to normal valve operation, simply release the button.

SAFETY AVAILABLE ON FOLLOWING MODELS:


PUSH AND TWIST STYLE
x 2 way 2 position pilot operated normally open series 8A / 8I
x 2 way 2 position direct acting poppet style normally open series 8I
x 2 way 2 position direct acting double lock normally closed series 8I
OPERATION
To operate manual override, screw out the knob protection after removing wire-
locking and turn clockwise and release override button.
To return to normal valve operation, push override button, turn counterclockwise and
release.

SAFETY AVAILABLE ON FOLLOWING MODELS:


SCREW-IN STYLE
x 2 way 2 position pilot operated normally open series 8I
x 2 way 2 position direct acting poppet style normally open series 8I
x 2 way 2 position direct acting double lock normally closed series 8I
OPERATION
Safety manual override has been designed to avoid accidental operation of the
emergency device.
Manual override can be operated only screwing out the knob, removing the coil and
screwing the knob completely in again.
To return to normal valve operation it is necessary to turn out the knob and mount the
coil again.

Rev. 06.05 7.01.030.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL
TECHNICAL DATA
DATA

HYDRAULIC FLUID

GENERAL PROPERTIES VISCOSITY KINEMATIC VISCOSITY


Hydraulic fluid must have physical, lubricating and chemical
properties suitable for use in hydraulic systems such as, for Maximum Medium Minimum
example
CLASS at 32°F (0°C) at 104°F (40°C) at 212°F (100°C)
MINERAL BASED HYDRAULIC OILS HL DIN 51524 Part 1 ISO VG 10 90 10 2.4
MINERAL BASED HYDRAULIC OILS HLP DIN 51524 Part 2
ISO VG 22 300 22 4.1
ISO VG 32 420 32 5.0
VISCOSITY CLASS ISO 3448 - DIN 51519
ISO VG 46 780 46 6.1
ISO viscosity class is expressed by ISO VG followed by
one number representing the medium kinematic viscosity at ISO VG 68 1400 68 7.8
2
104°F 40°C in mm /s or centiStokes cSt ISO VG 100 2560 100 9.9

FUNCTIONAL TESTING - TEMPERATURES - INTERNAL LEAKAGE

FUNCTIONAL TESTING FLUID TEMPERATURE RANGE


All performance curves in this catalogue are obtained using -22°F (-30°C) to +212°F (+100°C)
mineral based hydraulic oil with 46 cSt viscosity at 104°F AMBIENT TEMPERATURE RANGE
(40°C) (ISO VG 46 viscosity class).
NON SOLENOID VALVES -22°F (-30°C) to +212°F (+100°C)
All valves go through functional testing at these conditions
before shipment. Our test stands ensure 10 micron SOLENOID VALVES SEE COIL PAGES
ABSOLUTE FILTRATION. Please consult us for different temperature ranges.
All performance curves represent the average of real
values measured on tested valves. For this reason a INTERNAL LEAKAGE - POPPET VALVES
tolerance of ± 15-29 psi (1-2 bar) for pressure drop and ±
20-30 ms for response time has to be considered normal MAXIMUM ALLOWABLE INTERNAL LEAKAGE of all
and acceptable. poppet valves cannot exceed 0.06 in3/min (1 cm3/min) (15-
20 drops/min) at the maximum working pressure with 46
The electrical parameters and the response times of the
cSt oil viscosity. Actual leakage is expected, on average, to
ON-OFF solenoid valves are measured using 24 V DC
be less than 10 drops/min and anyway tends to decrease
coils at stabilized temperature and nominal voltage. Tests
after few seconds.
on proportional valves are performed using 12 V DC coils.

SEALS

O - RINGS
ORDERING CODE:
Acryl - Nitrile Butadiene Rubber NBR ( BUNA-N ) standard for
temperatures between -22°F (-30°C) and +212°F (+100°C). CARTRIDGE VALVES Substitute OD with KD
FLUOROCARBON FPM ( Viton ) and other compounds are VALVES IN STANDARD MANIFOLD Same as cartridge KIT
available on request. VALVES IN EMERGENCY MANIFOLD Substitute OE with KE

BACKUP RINGS EXAMPLES:


LUBRIFLON - PTFE
VALVE CODE: OD.15.32.18.18.00
OS.15.32.18.18.02
SEAL KITS
SEAL KIT CODE: KD.15.32.18.18.00
SEAL KITS include ALL EXTERNAL SEALS. Internal seals
of cartridge valves are not included, since the customer is VALVE CODE: OE.15.05.18.37.02
not allowed to disassemble cartridge valves. SEAL KIT CODE: KE.15.05.18.37.02

Rev.06.05 7.01.040.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA

CARTRIDGE INSTALLATION
It is recommended to follow these steps: x Inspect cavity for burrs or other machining irregularities
x Inspect the cartridge to ensure that no external which could damage seals during installation.
contaminant is present. x Dip the cartridge in clean oil.
x Check that O-ring and back-up rings are intact and x Screw the cartridge in BY HAND until the O-ring is met,
correctly positioned. The O-ring should be towards the then tighten to the torque specified in the cartridge
higher pressure port if only one back-up ring is present catalogue page. Do not exceed maximum torque:
or between double back-up rings if both ports receive overtightening may cause valve failure.
high pressure.

IMPORTANT: Continuous high frequency vibrations especially if combined with pulsating pressure, may cause cartridge
unscrewing and consequent O-ring extrusion. Please consult our Technical Department.

COIL INSTALLATION

COIL WITH O-RING SEATS (S7 - S5) COIL WITHOUT O-RING SEATS (S8-356)
It is recommended to follow these steps: It is recommended to follow these steps:
x Insert 1st O-Ring (see drawing) x Insert 1st O-Ring (see drawing)
x Insert coil x Insert coil
x Insert 2nd O-Ring (see drawing) x Tighten BY HAND coil retaining nut to the torque
x Tighten BY HAND coil retaining nut to the torque specified in the cartridge catalogue page. The 2nd O-
specified in the cartridge catalogue page. Ring is fixed inside the nut.

Example: Example:

Nut
Nut
2nd O-Ring
2nd O-Ring

Coil
Coil
1st O-Ring

1st O-Ring

IMPORTANT: O-rings are the only protection against water infiltration between tube and coil, which may lead in short time to
coil failure. The proper mounting of both O-rings is therefore necessary to ensure normal life of coils when operating in presence
of water, ice, moisture etc. Oil Control cannot guarantee any IP protection degree if both O-rings are not properly mounted on
coils.

Rev.06.05 7.01.045.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL
TECHNICAL DATA
DATA
CONTAMINATION
CONTAMINATION -- FILTRATION
FILTRATION

GENERAL INFORMATION ABSOLUTE FILTRATION RATING ISO 4572


Manufactures and users of hydraulic equipment admit that It’s the diameter X of the largest particle with BETAx • 75.
contamination is the most likely cause of malfunction or
failure in hydraulic systems and reduces security and
reliability of components and systems. Metal particles CONTAMINATION CLASS ISO 4406:1999
flowing throughout the circuit scratch moving surfaces so It’s expressed by 3 scale numbers representing
that contaminaton level, if not controlled, increases very respectively: the number of particles equal to or larger than
rapidly. 4 —m(c); the number of particles equal to or larger than 6
It is strongly recommended to mantain contamination level —m(c); the number of particles equal to or larger than 14
at least at nominal values shown below, choosing adequate —m(c), contained in 0.034 oz (1 ml) of fluid.
filtration products.
CONTAMINATION CLASS NAS 1638
FILTRATION RATIO BETAx It’s expressed by one scale numbers representing the
It’s the ratio between the number of particles before and number of particles of different size ranges contained in 3.4
after the filter with diameter larger than X micron. oz (100 ml) of fluid.

MINIMUM FILTRATION RECOMMENDATIONS


TYPE OF SYSTEM REQUIRED FOR EXTENDED PRODUCT LIFE

ABSOLUTE
NOMINAL FILTRATION CONTAMINATION
TYPE OF VALVE FILTRATION RATING ACCORDING TO
ISO 4572

(—m) BETAx • 75 ISO 4406:1999 NAS 1638

PROPORTIONAL VALVES 6 X = 6…10 18 / 16 / 13 7

Systems/components operating at
HIGH PRESSURE > 3600 psi (250 bar)

HIGH CYCLE APPLICATIONS 10 X = 10…12 19 / 17 / 14 8

Sistems/components with LOW dirt


tolerance

Systems/components operating at
MEDIUM PRESSURE up to 3600 psi 15 X = 12…15 20 / 18 / 15 9
(250 bar)

Systems/components operating at
LOW PRESSURE < 1450 psi (100 bar)

LOW CYCLE APPLICATIONS 25 X = 15…25 21 / 19 / 16 10

Systems/components with GOOD


dirt tolerance.
Rev.06.05 7.01.050.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Pressure Control Valves

VSBN-08A
VSPY-10A

VSBN-10A

VSPY-10A

VSBG-10A

VSPY-10A
VSNG-10A

VRPP-10A

VSPN-10A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY

VSBN-08A SIZE 08
VSBN-08A 04.11.49 - XSIZE
- 56 08
-Z 04.11.49 - X - 56 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 5 gpm (20 l/min)

Cavity : CA-08A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 25-30 ft-lb (34-41 Nm)


Flow is blocked from 1 to 2 until pressure increases to meet the selected valve
setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank.
Pressure at port 2 is additive to the relief setting of the valve. The unique Oil Control Weight: 0.309 lbs (0.140 Kg)
poppet design provides enhanced stability at all flows and pressures.

X ADJUSTMENTS

03 Leakproof hex. socket screw

04 Handknob and locknut

73 O-Ring seal on adjust screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
145-1000 375 725
05 (10-70) (26) (50)
500-2000 725 1450 X = 03 11.04.23.002
10 (35-140) (50) (100)
X = 03 1500-3000 1145 2900
20 (105-210) (79) (200)
Tamper resistant cap
35
2500-5000 2465 5000 X = 73 11.04.23.004
(175-350) (170) (350)
500-5000 1044 2900
X = 04 35 (35-350) (72) (200) Special settings available. Contact factory authorized
500-5000 1044 2900 representative for ordering code.
X = 73 35 (35-350) (72) (200)
Rev.0605 Page. AA1.020

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY

VSBN-10A SIZE 10
VSBN-10A 04.11.55 - XSIZE
- 85 10
-Z 04.11.55 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 13 gpm (50 l/min)

Cavity : CA-10A-2N (see page CT.A.001.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


Flow is blocked from 1 to 2 until pressure increases to meet the selected valve
setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank.
Pressure at port 2 is additive to the relief setting of the valve. The unique Oil Control Weight: 0.430 lbs (0.195 Kg)
poppet design provides enhanced stability at all flows and pressures.

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)

75-1000 232 725


05 (5-70) (16) (50)
500-2000 348 1450 11.04.23.002
10 (35-140) (24) (100) Tamper resistant cap
1500-3000 783 2900
20 (105-210) (54) (200)
2500-5000 1218 5000 Special settings available. Contact factory authorized
35 (175-350) (84) (350) representative for ordering code.
Rev.0906 Page. AA1.030

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY

VSBG-10A SIZE 10
VSBG-10A 04.11.56 - XSIZE
- 85 10
-Z 04.11.56 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 13 gpm (50 l/min)

Cavity : CA-10A-2N (see page CT.A.001.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


Flow is blocked from 2 to 1 until pressure increases to meet the selected valve
setting, lifting the poppet from its seat and allowing relief flow through port 1 to tank.
Pressure at port 1 is additive to the relief setting of the valve. The unique Oil Control Weight: 0.430 lbs (0.195 Kg)
poppet design provides enhanced stability at all flows and pressures.

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)

75-1000 232 725


05 (5-70) (16) (50)
500-2000 348 1450 11.04.23.002
10 (35-140) (24) (100) Tamper resistant cap
1500-3000 783 2900
20 (105-210) (54) (200)
2500-5000 1218 5000 Special settings available. Contact factory authorized
35 (175-350) (84) (350) representative for ordering code.
Rev.0906 Page. AA1.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, BI-DIRECTIONAL RELIEF, BI-DIRECTIONAL
DIRECT ACTING POPPET TYPE DIFFERENTIAL
DIRECT AREATYPE DIFFERENTIAL AREA
ACTING POPPET
COMMON CAVITY COMMON CAVITY
VSNG-10A SIZE 10
VSNG-10A 04.11.59 - XSIZE
- 85 10
-Z 04.11.59 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 15 gpm (56 l/min)

Cavity : CA-10A-2N (see page CT.A.001.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


Flow is blocked bi-directionally between 1 and 2 until pressure at either port
increases to meet the selected valve setting, lifting the poppet from its seat and
allowing relief flow to the opposite port. The unique Oil Control poppet design Weight: 0.551 lbs (0.250 Kg)
provides consistent cracking pressures at both ports and enhanced stability at all
flows and pressures.
Maximum difference for crack pressure in both direction : 145 psi (10 bar)

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar)
(bar) (bar/turn) (Q=5 l/min)

450-1450 196 1450


10 (30-100) (13.5) (100)

1450-3000 450 2900


20 (100-210) (31) (200)

Rev.0706 Page. AA1.042

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, PILOT
RELIEF, PILOT OPERATED
OPERATED SPOOL
SPOOL TYPE
TYPE
COMMON CAVITY
COMMON CAVITY

VSPN-10A
VSPN-10A SIZE 10 04.12.08
04.12.08 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)

Max. flow: 32 gpm (120 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-10A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


Flow is blocked from 1 to 2 until pressure increases to meet the selected valve
setting, lifting the conical, pilot-stage poppet from its seat. This action exhausts oil Installation torque : 30-35 ft-lb (41-47 Nm)
above the main-stage piston (spool type), allowing it to shift and provide relief flow
through 2 to tank. Pressure at 2 is additive to the relief setting of the valve.
Weight: 0.463 lbs (0.210 Kg)

X ADJUSTMENTS

03 Leakproof hex. socket screw

04 Handknob and locknut

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
X = 03 2000-6000 2030 5000 11.04.23.002
35 (140-420) (140) (350) Tamper resistant cap

Special settings available. Contact factory authorized


500-5000 986 5000 representative for ordering code.
X = 04 35 (35-350) (68) (350)
Rev.0605 Page. AA1.050

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, PILOT OPERATED RELIEF,
SPOOL TYPE
PILOT OPERATED SPOOL TYPE
EXTERNAL DRAIN EXTERNAL DRAIN
COMMON CAVITY COMMON CAVITY
VSPY-10A SIZE 10
VSPY-10A 04.13.05 - XSIZE
- 8510
-Z 04.13.05 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)

Max. flow: 32 gpm (120 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-10A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011


Flow is blocked from 1 to 2 until pressure increases to meet the selected valve
setting, lifting the conical, pilot-stage poppet from its seat. This action exhausts oil Installation torque : 30-35 ft-lb (41-47 Nm)
above the main-stage piston (spool type), allowing it to shift and provide relief flow
through 2 to tank. The spring chamber is drained to tank at 3 allowing a consistent
relief setting independent of back-pressure at 2. Weight: 0.463 lbs (0.210 Kg)

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
2000-6000 2030 5000 11.04.23.002
35 (140-420) (140) (350) Tamper resistant cap

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0607 Page. AA1.070

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING,
PRESSURE REDUCING, PILOT
PILOT OPERATED
OPERATED SPOOL
SPOOL TYPE
TYPE
COMMON CAVITY
COMMON CAVITY

VRPP-10A SIZE 10 04.93.06


04.93.06 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. regulated pressure: 4000 psi (280 bar)

Max. flow: 16 gpm (60 l/min)

Cavity : CA-10A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01«

External seal kit : see page A11.011


Initially, flow passes freely from 2 to 1. When the pressure at 1 exceeds the pressure
setting, the valve acts to restrict input flow at 2. This increases the pressure drop Installation torque : 30-35 ft-lb (41-47 Nm)
through the valve and maintains consistent pressure at 1. The spring chamber is
drained at 3 to prevent a build-up of back-pressure against the spool. Weight: 0.463 lbs (0.210 Kg)

Std. internal orifice : 0.6 mm

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi Ordering code Description
(bar) (bar/turn) (bar)
145-2000 696 1450
10 (10-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
11.04.23.002
Tamper resistant cap

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0607 Page. AA2.010

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING
PRESSURE REDUCING AND
AND RELIEVING,
RELIEVING,
PILOT OPERATED SPOOL TYPE
PILOT OPERATED SPOOL TYPE
COMMON CAVITY
COMMON CAVITY
VRPX-10A SIZE 10 04.93.07
04.93.07 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 16 gpm (60 l/min)

Cavity : CA-10A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


Initially, flow passes freely from 2 to 1. When the pressure at 1 exceeds the pressure
setting, the conical poppet in the upper, pilot stage is lifted from its seat. This allows Weight: 0.441 lbs (0.200 Kg)
the main-stage piston to shift, restricting input flow at 2. This increases the pressure
drop through the valve and maintains consistent pressure at 1. The spring chamber Std. internal orifice : 0.6 mm
is drained at 3 to prevent a build-up of back-pressure against the spool. Additionally,
if pressure at 1 rises above the pressure setting, flow is relieved to 3 until the setting
is re-attained.

X ADJUSTMENTS

03 Leakproof hex. socket screw

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (reduc. mode)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
11.04.23.002
Tamper resistant cap

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0607 Page. AA2.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING
PRESSURE REDUCING AND
AND RELIEVING,
RELIEVING,
DIRECT ACTING SPOOL TYPE
DIRECT ACTING SPOOL TYPE
COMMON CAVITY
COMMON CAVITY
VRPR-10A SIZE 10 04.95.04
04.95.04 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure (*): 5000 psi (350 bar)

Max. flow: 8 gpm (30 l/min)

3 3
Int. leakage ave. : 3 in /min (50 cm /min)

Cavity : CA-10A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011


Initially, flow passes freely from 2 to 1. When the pressure at 1 exceeds the pressure
setting, the valve acts to restrict input flow at 2. This increases the pressure drop Installation torque : 30-35 ft-lb (41-47 Nm)
through the valve and maintains consistent pressure at 1. The spring chamber is
drained at 3 to prevent a build-up of back-pressure against the spool. Additionally, if Weight: 0.573 lbs (0.260 Kg)
pressure at 1 rises above the pressure setting, flow is relieved to 3 until the setting is
re-attained. (*) Max pressure for
3000 psi (210 bar)
Z=01 version

X ADJUSTMENTS

03 Leakproof hex. socket screw

04 Handknob and locknut

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (reduc. mode)
30-200 29 115-145
01 (2-14) (2) (8-10)
30-350 44 100-145
02 (2-25) (3) (7-10)
145-725 102 500-580 11.04.23.004
04 (10-50) (7) (35-40) Tamper resistant cap
400-1160 203 650-725
08 (28-80) (14) (45-50)

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0906 Page. AA2.030

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Special Valves

VPN1

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, HOSE BURST CHECK, HOSE BURST

VPN1 VPN1 0T.F4.01 - X - Y - Z 0T.F4.01 - X - Y - Z

TECHNICAL DATA
Max. pressure: 4500 psi (315 bar)
Flow: see below graphs (‘R’-Q)
Special flow settings available. Please contact factory
authorized representative for ordering code.
Note: on request are available as “in line mounted sleeves
type configuration”. Please contact factory for any
information.
The valve is only supposed to be operated in case of
hose failure. Should this circumstance occur, we
strongly recommend to verify the integrity of the valve
and eventually to replace it in the event that the
pressure spike generated by the hose failure was such
to damage permanently some valve components.
When the lowering speed exceeds preset value, as it might happen in case of hose
failure, the flow is blocked. These valves should ideally be screwed directly into the
actuator outlet port. Sealing parts are superfinished and enable to lock the load in the X ADJUSTMENTS
position where the actuator is in the moment of hose failure. These valves can be
Locking nut + counter nut
supplied, on request, with an orifice on the disc, allowing an emergency lowering of 03 see graphs (‘R’ - Q)
the load. It is recommended to fit a flow regulator valve downstream the hose burst
valve, at the end of the flexible hose, to control the lowering speed at the nominal
value. The “R” gap must be adjusted to allow a flow at least 50% over the nominal
regulated flow from the actuator.

Y PORTS
09 G 1/4
02 G 3/8
03 G 1/2
04 G 3/4

Z ORIFICE DIAMETER (mm)


00 no orifice 06 1
01 0.5 07 1.2
02 0.6 08 1.3
03 0.7 09 1.5
04 0.8 10 1.9
05 0.9 11 2

FITTING TOOL DIMENSION

Rev.0905 Page. AT9.020

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Check Valves

VUH1

VSON-08A

VSON-10A

VSON-12A

VSON-16A

VUCN-08A

VUCN-10A

VUCN-12A

VUCN-16A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET
CHECK, POPPET TYPE
TYPE

VUH1
VUH1 0T.U5.01.00 --YY--ZZ
0T.U5.01.00

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow : see diagram

Note : valves are burnished.

When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining
and hardening processes allow virtually leak-free performance in the checked
condition.

FITTING TOOL DIMENSION

Cracking pressure
Z psi (bar) Y PORTS

00 < 7 (< 0.5)


09 G 1/4

02 G 3/8

03 G 1/2

Rev.0905 Page. AT4.050

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED CHECK,PILOT
PILOTOPERATED
TO OPEN CHECK, PILOT TO OPEN
COMMON CAVITY COMMON CAVITY

VSON-08A SIZE 08
VSON-08A 04.33.06 - XSIZE
- 5608
-Z 04.33.06 - X - 56 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 8 gpm (30 l/min)

Pilot ratio : 3:1

Cavity : CA-08A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


When pressure at 2 rises above the spring bias pressure, the poppet is pushed from
its seat and flow is allowed from 2 to 1. The valve is normally closed (checked) from Installation torque : 25-30 ft-lb (34-41 Nm)
1 to 2. When sufficient pilot pressure is present at port 3, the pilot piston acts to push
the poppet from its seat and flow is allowed from 1 to 2. Precision machining and Weight: 0.265 lbs (0.120 Kg)
hardening processes allow virtually leak-free performance in the checked condition.

X O-RING ON PILOT PISTON

00 No O-Ring

10 With O-Ring

SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)

Rev.0605 Page. AA4.070

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED
PILOT OPERATED CHECK,
CHECK, PILOT
PILOT TO
TO OPEN
OPEN
COMMON CAVITY
COMMON CAVITY

VSON-10A
VSON-10A SIZE 10 04.33.05
04.33.05 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 16 gpm (60 l/min)

Pilot ratio : 3.2 : 1

Cavity : CA-10A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


When pressure at 2 rises above the spring bias pressure, the poppet is pushed from
its seat and flow is allowed from 2 to 1. The valve is normally closed (checked) from Installation torque : 30-35 ft-lb (41-47 Nm)
1 to 2. When sufficient pilot pressure is present at port 3, the pilot piston acts to push
the poppet from its seat and flow is allowed from 1 to 2. Precision machining and Weight: 0.265 lbs (0.120 Kg)
hardening processes allow virtually leak-free performance in the checked condition.

X O-RING ON PILOT PISTON

00 No O-Ring

10 With O-Ring

SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)

Rev.0605 Page. AA4.080

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED CHECK,PILOT
PILOTOPERATED
TO OPEN CHECK, PILOT TO OPEN
COMMON CAVITY COMMON CAVITY

VSON-12A SIZE 12
VSON-12A 04.33.07 - XSIZE
- 5712
-Z 04.33.07 - X - 57 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 32 gpm (120 l/min)

Pilot ratio : 3.2 : 1

Cavity : CA-12A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


When pressure at 2 rises above the spring bias pressure, the poppet is pushed from
its seat and flow is allowed from 2 to 1. The valve is normally closed (checked) from Installation torque : 60-70 ft-lb (81-95 Nm)
1 to 2. When sufficient pilot pressure is present at port 3, the pilot piston acts to push
the poppet from its seat and flow is allowed from 1 to 2. Precision machining and Weight: 0.551 lbs (0.250 Kg)
hardening processes allow virtually leak-free performance in the checked condition.

X O-RING ON PILOT PISTON

00 No O-Ring

10 With O-Ring

SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)

Rev.0605 Page. AA4.090

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED
PILOT OPERATED CHECK,
CHECK, PILOT
PILOT TO
TO OPEN
OPEN
COMMON CAVITY
COMMON CAVITY

VSON-16A
VSON-16A SIZE 16 04.33.08
04.33.08 -- X
X -- 27
27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

Pilot ratio : 3:1

Cavity : CA-16A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.012


When pressure at 2 rises above the spring bias pressure, the poppet is pushed from
its seat and flow is allowed from 2 to 1. The valve is normally closed (checked) from Installation torque : 80-90 ft-lb (108-122 Nm)
1 to 2. When sufficient pilot pressure is present at port 3, the pilot piston acts to push
the poppet from its seat and flow is allowed from 1 to 2. Precision machining and Weight: 0.706 lbs (0.320 Kg)
hardening processes allow virtually leak-free performance in the checked condition.

X O-RING ON PILOT PISTON

00 No O-Ring

10 With O-Ring

SPRINGS
Z Cracking pressure
psi
(bar)
22
00 (1.5)

Rev.0605 Page. AA4.100

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY

VUCN-08A SIZE 08
VUCN-08A 04.31.20.00.56
SIZE -08
Z 04.31.20.00.56 - Z

TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)

Max. flow: 13 gpm (50 l/min)

Cavity : CA-08A-2N (see page CT.A.001.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011

Installation torque : 25-30 ft-lb (34-41 Nm)


When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining Weight: 0.265 lbs (0.120 Kg)
and hardening processes allow virtually leak-free performance in the checked
condition.

SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
39
03 (2.7)
75
05 (5)
200
14 (14)

Rev.0605 Page AA4.010

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY

VUCN-10A SIZE 10
VUCN-10A 04.31.23.00.85
SIZE -10
Z 04.31.23.00.85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 21 gpm (80 l/min)

Cavity : CA-10A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining Weight: 0.331 lbs (0.150 Kg)
and hardening processes allow virtually leak-free performance in the checked
condition.

SPRINGS
Z Cracking pressure
psi
(bar)
7
00 (0.5)
75
05 (5)
220
15 (15)

Rev.0605 Page. AA4.020

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET
CHECK, POPPET TYPE
TYPE
COMMON CAVITY
COMMON CAVITY

VUCN-12A
VUCN-12A SIZE 12 04.31.28.00.57
04.31.28.00.57 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 32 gpm (120 l/min)

Cavity : CA-12A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 60-70 ft-lb (81-95 Nm)


When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining Weight: 0.397 lbs (0.180 Kg)
and hardening processes allow virtually leak-free performance in the checked
condition.

SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
75
05 (5)
220
15 (15)

Rev.0605 Page. AA4.030

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY

VUCN-16A SIZE 16
VUCN-16A 04.31.25.00.27
SIZE -16
Z 04.31.25.00.27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

Cavity : CA-16A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.012

Installation torque : 80-90 ft-lb (108-122 Nm)


When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining Weight: 0.595 lbs (0.270 Kg)
and hardening processes allow virtually leak-free performance in the checked
condition.

SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
30
02 (2)

Rev.0605 Page. AA4.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Counterbalance Valves

VBSN-08AA

VBSN-10A

VBSN-12A

VBSN-16A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD GUIDED POPPET
COUNTERBALANCE, TYPE
STANDARD GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY

VBSN-08AA SIZE 08
VBSN-08AA 04.52.20 - XSIZE
- 56 08
-Z 04.52.20 - X - 56 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 8 gpm (30 l/min)

Cavity : CA-08A-3C (see page A10.011)

/LQHERGLHVVHHSDJH$±$

External seal kit : see page A11.011

Installation torque : 25-30 ft-lb (34-41 Nm)


When pressure at 2 rises above the spring bias pressure, the check seat is pushed
away from the piston and flow is allowed from 2 to 1. When load pressure at 1 rises
above the pressure setting, the direct-acting, relief function is activated and flow is Weight: 0.397 lbs (0.180 Kg)
relieved from 1 to 2. With pilot pressure at 3, the pressure setting is reduced in
proportion to the stated ratio of the valve, until fully open with free-flow from 1 to 2. Pressure setting: at least 1.3 times the load induced
The spring chamber is drained to 2, and any back-pressure at 2 is additive to the pressure.
pressure setting in all functions.

X PILOT RATIO

03 4:1

33 4:1 With sealed pilot

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-2200 1051 2200
15 (70-150) (72.5) (150)
03.51.01.329
1450-3000 1581 2900
20 (100-210) (109) (200)
03.51.01.328
2900-5000 1987 5000 11.04.23.002
35 (200-350) (137) (350)
03.51.01.327
Tamper resistant cap

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0306 Page AA5.010

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD
COUNTERBALANCE, STANDARD POPPET
POPPET TYPE
TYPE
DIFFERENTIAL AREA
DIFFERENTIAL AREA
COMMON CAVITY
COMMON CAVITY
VBSN-10A
VBSN-10A SIZE 10 04.52.31
04.52.31 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 16 gpm (60 l/min)

Cavity : CA-10A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


When pressure at 2 rises above the spring bias pressure, the check seat is pushed
away from the piston and flow is allowed from 2 to 1. When load pressure at 1 rises
above the pressure setting, the direct-acting, differential area relief function is Weight: 0.441 lbs (0.200 Kg)
activated and flow is relieved from 1 to 2. With pilot pressure at 3, the pressure
setting is reduced in proportion to the stated ratio of the valve, until fully open with Pressure setting: at least 1.3 times the load induced
free-flow from 1 to 2. The spring chamber is drained to 2, and any back-pressure at pressure
2 is additive to the pressure setting in all functions.

X PILOT RATIO

03 3:1

10 8:1

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 1958 2900
20 (70-210) (135) (200)
X = 03 2000-5000 2842 5000
35 (140-350) (196) (350)
1000-3000 754 2900 11.04.23.002
20 (70-210) (52) (200) Tamper resistant cap
X = 10 2000-5000 1291 5000
35 (140-350) (89) (350)

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0605 Page. AA5.030

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD POPPET TYPESTANDARD POPPET TYPE
COUNTERBALANCE,
DIFFERENTIAL AREA DIFFERENTIAL AREA
COMMON CAVITY COMMON CAVITY
VBSN-12A SIZE 12
VBSN-12A 04.52.28 - XSIZE
- 5712
-Z 04.52.28 - X - 57 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 32 gpm (120 l/min)

Cavity : CA-12A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 60-70 ft-lb (81-95 Nm)


When pressure at 2 rises above the spring bias pressure, the check seat is pushed
away from the piston and flow is allowed from 2 to 1. When load pressure at 1 rises
above the pressure setting, the direct-acting, differential area relief function is Weight: 0.860 lbs (0.390 Kg)
activated and flow is relieved from 1 to 2. With pilot pressure at 3, the pressure
setting is reduced in proportion to the stated ratio of the valve, until fully open with Pressure setting: at least 1.3 times the load induced
free-flow from 1 to 2. The spring chamber is drained to 2, and any back-pressure at pressure
2 is additive to the pressure setting in all functions.

X PILOT RATIO

03 4:1

10 8:1

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 725 2900
20 (70-210) (50) (200)
X = 03 2000-5000 2306 5000
35 (140-350) (159) (350)
1000-3000 609 2900 11.04.23.002
20 (70-210) (42) (200) Tamper resistant cap
X = 10 2000-5000 972 5000
35 (140-350) (67) (350)

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0605 Page. AA5.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD
COUNTERBALANCE, STANDARD POPPET
POPPET TYPE
TYPE
DIFFERENTIAL AREA
DIFFERENTIAL AREA
COMMON CAVITY
COMMON CAVITY
VBSN-16A
VBSN-16A SIZE 16 04.52.29
04.52.29 -- X
X -- 27
27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

Cavity : CA-16A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.012

Installation torque : 80-90 ft-lb (108-122 Nm)


When pressure at 2 rises above the spring bias pressure, the check seat is pushed
away from the piston and flow is allowed from 2 to 1. When load pressure at 1 rises
above the pressure setting, the direct-acting, differential area relief function is Weight: 1.808 lbs (0.820 Kg)
activated and flow is relieved from 1 to 2. With pilot pressure at 3, the pressure
setting is reduced in proportion to the stated ratio of the valve, until fully open with Pressure setting: at least 1.3 times the load induced
free-flow from 1 to 2. The spring chamber is drained to 2, and any back-pressure at pressure
2 is additive to the pressure setting in all functions.

X PILOT RATIO

03 4:1

10 8:1

SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 1015 2900
20 (70-210) (70) (200)
X = 03 2000-5000 1566 5000
35 (140-350) (108) (350)
2000-6000 1958 5000 11.04.23.004
X = 10 40 (140-420) (135) (350) Tamper resistant cap

Special settings available. Contact factory authorized


representative for ordering code.

Rev.0605 Page. AA5.050

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Flow Control Valves

STVU-08A

VRFB-10A

VRFD-10

DRFN-10A

ST-C-06

ST-C-10A

ST-C-12A

ST-C-16A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
NEEDLE RESTRICTOR,
NEEDLE RESTRICTOR, FREE
FREE REVERSE
REVERSE FLOW
FLOW
COMMON CAVITY
COMMON CAVITY

STVU-08A
STVU-08A SIZE 08 04.01.02
04.01.02 -- X
X -- 56.00

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 11 gpm (40 l/min)

Cavity : CA-08A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 25-30 ft-lb (34-41 Nm)


With flow from 2 to 1, the valve provides a fully adjustable orifice restriction. Free
flow is permitted from 1 to 2, regardless of valve adjustment, by when pressure
overcomes the spring bias of the valve’s check function. Weight: 0.353 lbs (0.160 Kg)

X ADJUSTMENTS

03 Leakproof hex. socket screw

04 Handknob and locknut

Rev.0605 Page. AA7.010

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL, 2-WAY PRESSURE COMPENSATED
FLOW CONTROL, 2-WAY PRESSURE COMPENSATED
FULLY ADJUSTABLE FULLY ADJUSTABLE
COMMON CAVITY COMMON CAVITY
VRFB-10A SIZE 10
VRFB-10A 04.02.02 - XSIZE
- 8510
-Z 04.02.02 - X - 85 - Z

TECHNICAL DATA
Pressure min-max: 200-5000 psi (14-350 bar)

Flow range: see below

Cavity : CA-10A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011

Installation torque : 30-35 ft-lb (41-47 Nm)


A constant flow rate, regardless of system pressures, is established from 1 to 2 while
a minimum pressure differential of 200 psi exists between the two ports. Output flow Weight: 0.595 lbs (0.270 Kg)
can be varied from closed to the nominal maximum rating for the valve. Flow from 2
to 1 is limited by the diameter of the selected control orifice and is not pressure
compensated.

X ADJUSTMENTS

40 Calibrated handknob

04 Handknob

Z REGULATED FLOW RANGE


20 0.01-5.28 gpm 0.05-20 l/min
40 0.03-7.93 gpm 0.10-30 l/min

Rev.0605 Page. AA7.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL, 3-WAY PRESSURE COMPENSATED
FLOW CONTROL, 3-WAY PRESSURE COMPENSATED
COMBINATION TYPE FULLY ADJUSTABLE
COMBINATION TYPE FULLY ADJUSTABLE
COMMON CAVITY COMMON CAVITY
VRFD-10A SIZE 10
VRFD-10A 04.04.02 - XSIZE
- 8510
-Z 04.04.02 - X - 85 - Z

TECHNICAL DATA
Pressure min-max: 200-5000 psi (14-350 bar)

Max inlet flow: 16 gpm (60 l/min)

Flow range: see below

Cavity : CA-10A-3N (see page CT.A.003.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


A constant flow rate, regardless of system pressures, is established from 1 to 3 while
a minimum pressure differential of 200 psi exists between the two ports. Input flow Installation torque : 30-35 ft-lb (41-47 Nm)
supplied to 1 in excess of the regulated output at 3 is by-passed to 2. Output flow
can be varied from closed to the nominal maximum rating for the valve. Flow from 3 Weight: 0.573 lbs (0.260 Kg)
to 1 is limited by the diameter of the selected control orifice and is not pressure
compensated. Flow from 2 to 1 is not permitted.

X ADJUSTMENTS

40 Calibrated handknob

04 Handknob

Z REGULATED FLOW RANGE


20 0.01-5.28 gpm 0.05-20 l/min
40 0.03-7.93 gpm 0.10-30 l/min

Rev.0605 Page. AA7.060

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW DIVIDER
FLOW DIVIDER AND
AND COMBINER
COMBINER
COMMON CAVITY
COMMON CAVITY

DRFN-10A
DRFN-10A SIZE 10 04.05.01.00.85
04.05.01.00.85 - Z

TECHNICAL DATA
Pressure min-max: 145-5000 psi (10-350 bar)

Range of rated total flow: see table Z

Division or combination ratio: 50%-50%

Cavity : CA-10A-4N (see page CT.A.004.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


Input flow at 3 will be divided and output equally to 2 and 4 independent of system
pressures. Flow input at 2 and 4 will be combined and output at 3. Should either 2 Installation torque : 30-35 ft-lb (41-47 Nm)
or 4 become blocked in flow division mode, approximately 5% of the input flow will be
transmitted to the open port. Weight: 0.617 lbs (0.280 Kg)
Slippage (tolerance) from theoretical divided flows:
±5% to ±10%, depending from inlet flow (see diagram).
N.B.: slippage is lowest toward upper limit of nominal range.

Z RANGE OF TOTAL FLOW


02 0.26-0.79 gpm 1-3 l/min
04 0.53-1.59 gpm 2-6 l/min
08 1.32-3.44 gpm 5-13 l/min
16 2.38-6.34 gpm 9-24 l/min
25 3.70-9.78 gpm 14-37 l/min
30 4.23-11.63 gpm 16-44 l/min
40 5.28-14.27 gpm 20-54 l/min

Rev.0605 Page. AA7.090

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL VALVES FLOW CONTROL VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY COMMON CAVITY
ST-C-06 SIZE 08
ST-C-06 OD.21.01 SIZE
- X - 56
08 OD.21.01 - X - 56

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure

Rated Flow 11 gpm (40 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

Line bodies page MN2.A…

Weight 0.199 lbs (0.090 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
3.7 ft-lb (5 Nm)
at 5000 psi (350 bar)

Mounting Position unrestricted

X ORDERING OPTIONS

03 Socket Screw

04 Handknob and Locknut

Rev.06.05 3.11.010.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL
FLOW CONTROL VALVES
VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY
COMMON CAVITY
ST-C-10A
ST-C-10A SIZE 10 OD.21.01
OD.21.01 -- XX -- 36
36

Hex. 1.06 / 32.5-41.3 ft-lb


Hex. (27) / (44-56) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (CA-10A-2N) page CT.A.001.U

Line bodies page MN1.A…

Weight 0.397 lbs (0.180 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
7.4 ft-lb (10 Nm)
at 5000 psi (350 bar)

Mounting Position unrestricted

X ORDERING OPTIONS

03 Socket Screw

04 Handknob and Locknut

Rev.06.05 3.15.020.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL VALVES FLOW CONTROL VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY COMMON CAVITY
ST-C-12A SIZE 12
ST-C-12A OD.21.01 SIZE
- X - 89
12 OD.21.01 - X - 89

Hex. 1.26 / 39.8-48.7 ft-lb


Hex. (32) / (54-66) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure

Rated Flow 39 gpm (150 l/min)

Cavity - Tooling (CA-12A-2N) page CT.A.001.U

Line bodies page MN1.A…

Weight 0.684 lbs (0.310 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
13.3 ft-lb (18 Nm)
at 5000 psi (350 bar)

Mounting Position unrestricted

X ORDERING OPTIONS

03 Socket Screw

04 Handknob and Locknut

Rev.06.05 3.15.030.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY

VUCN-16A SIZE 16
VUCN-16A 04.31.25.00.27
SIZE -16
Z 04.31.25.00.27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

Cavity : CA-16A-2N (see page CT.A.001.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.012

Installation torque : 80-90 ft-lb (108-122 Nm)


When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining Weight: 0.595 lbs (0.270 Kg)
and hardening processes allow virtually leak-free performance in the checked
condition.

SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
30
02 (2)

Rev.0605 Page. AA4.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Logic Elements

VLST-10A

VLST-16A

VLST-20A

VLSP-10A

VLSP-16A

VCSQ-16A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE CONTROL
PRESSURE CONTROL
WITH EXTERNAL PILOT
WITH EXTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLST-10A SIZE 10 04.84.01
04.84.01 -- X
X -- 85
85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 16 gpm (60 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-10A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.011


When pressure at 1 rises above the selected spring bias pressure against the spool,
the valve shifts to allow flow from 1 to 2. Pilot pressure at 3 is additive to the spring Installation torque : 30-35 ft-lb (41-47 Nm)
bias pressure. The valve may be used in switching or compensation type
applications.
Weight: 0.265 lbs (0.120 Kg)

X ADJUSTMENTS

00 Fixed setting

03 Leakproof hex. socket screw

SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
X = 00 115 ±15%
08 (8 ±15%)
30-115 15 60
X = 03 00 (2-8) (1) (4)

Rev.0605 Page. AA8.010

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, FLOW AND PRESSURE
LOGIC CONTROL
ELEMENT, FLOW AND PRESSURE CONTROL
WITH EXTERNAL PILOT WITH EXTERNAL PILOT
COMMON CAVITY COMMON CAVITY
VLST-16A VLST-16A
SIZE 16 04.84.01 - XSIZE
- 27 16
-Z 04.84.01 - X - 27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-16A-3C (see page CT.A.002.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.012


When pressure at 1 rises above the selected spring bias pressure against the spool,
the valve shifts to allow flow from 1 to 2. Pilot pressure at 3 is additive to the spring Installation torque : 80-90 ft-lb (108-122 Nm)
bias pressure. The valve may be used in switching or compensation type
applications.
Weight: 0.772 lbs (0.350 Kg)

X ADJUSTMENTS

00 Fixed setting

03 Leakproof hex. socket screw

SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
123 ±15%
08 (8.5 ±15%)
X = 00 175 ±10%
12 (12 ±10%)
218 ±10%
15 (15 ±10%)
60-175 22 60
X = 03 00 (4-12) (1.5) (4)

Rev.0607 Page. AA8.020

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE CONTROL
PRESSURE CONTROL
WITH EXTERNAL PILOT
WITH EXTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLST-20A SIZE 20 04.84.01
04.84.01 -- X
X -- 58
58 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 95 gpm (360 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-20A-3C (see page CT.A.002.U)

Line bodies : see page MN1.A…

External seal kit : see page A11.012


When pressure at 1 rises above the selected spring bias pressure against the spool,
the valve shifts to allow flow from 1 to 2. Pilot pressure at 3 is additive to the spring Installation torque : 95-110 ft-lb (128-149 Nm)
bias pressure. The valve may be used in switching or compensation type
applications.
Weight: 1.764 lbs (0.800 Kg)

X ADJUSTMENTS

00 Fixed setting

SPRINGS
Z Cracking press.
psi
(bar)
80
05 (5.5)
167
11 (11.5)

Rev.0605 Page. AA8.030

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, FLOW AND PRESSURE
LOGIC CONTROL
ELEMENT, FLOW AND PRESSURE CONTROL
WITH INTERNAL PILOT WITH INTERNAL PILOT
COMMON CAVITY COMMON CAVITY
VLSP-10A SIZE 10
VLSP-10A 04.84.03 - XSIZE
- 8510
-Z 04.84.03 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 16 gpm (60 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-10A-3C (see page CT.A.002.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011


When pressure at 1 rises above the selected spring bias pressure against the spool,
the valve shifts to allow flow from 1 to 2. The differential pressure between 1 and 3, Installation torque : 30-35 ft-lb (41-47 Nm)
across an internal orifice, is additive to the spring bias pressure. Note that flow,
restricted by the internal orifice, can be transmitted from 3 to 1. The valve may be Weight: 0.265 lbs (0.120 Kg)
used in switching or compensation type applications.
Standard internal
0.6 mm
orifice:

X ADJUSTMENTS

00 Fixed setting

03 Leakproof hex. socket screw

SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
X = 00 115 ±15%
08 (8 ±15%)
30-115 15 60
X = 03 00 (2-8) (1) (4)

Rev.0606 Page. AA8.040

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE
PRESSURE CONTROL
CONTROL
WITH INTERNAL PILOT
WITH INTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLSP-16A SIZE 16 04.84.03
04.84.03 -- X
X -- 27
27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 53 gpm (200 l/min)

2900 psi (200 bar)


Int. leakage ave. : 3 3
12 in /min (200 cm /min)

Cavity : CA-16A-3C (see page CT.A.002.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.012


When pressure at 1 rises above the selected spring bias pressure against the spool,
the valve shifts to allow flow from 1 to 2. The differential pressure between 1 and 3, Installation torque : 80-90 ft-lb (108-122 Nm)
across an internal orifice, is additive to the spring bias pressure. Note that flow,
restricted by the internal orifice, can be transmitted from 3 to 1. The valve may be Weight: 0.772 lbs (0.350 Kg)
used in switching or compensation type applications.
Standard internal
0.6 mm
orifice:

X ADJUSTMENTS

00 Fixed setting

03 Leakproof hex. socket screw

SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
115 ±15%
X = 00 08 (8 ±15%)
175 ±10%
12 (12 ±10%)
60-175 22 60
X = 03 00 (4-12) (1.5) (4)

Rev.0606 Page. AA8.050

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, PRESSURE COMPENSATOR
LOGIC ELEMENT, PRESSURE COMPENSATOR
COMBINATION TYPE COMBINATION TYPE
COMMON CAVITY COMMON CAVITY
VCSQ-16A VCSQ-16A
SIZE 16 04.84.06 - XSIZE
- 27 16
-Z 04.84.06 - X - 27 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. inlet flow: 53 gpm (200 l/min)

Max. priority flow: 32 gpm (120 l/min)

Flow maintenance: ± 10%

Cavity : CA-16A-4N (see page A10.013)

/LQHERGLHVVHHSDJH$±$
Flow is normally allowed from 4 to 3. When pilot pressure at 1 rises above the
combined pressure of the spring bias, plus pressure at 4, the valve shifts to block External seal kit : see page A11.012
flow between 3 and 4, while diverting flow from 1 to 2. A constant pressure drop is
maintained across a fixed (or variable) orifice upstream of 4 when installed and Installation torque : 80-90 ft-lb (108-122 Nm)
piloted per the diagram above. In this case, flow priority is given to 3, with flow in
excess of the orifice differential requirement being by-passed to 2.
Weight: 1.654 lbs (0.750 Kg)

X ADJUSTMENTS

00 Fixed setting

SPRINGS
Z Cracking pressure
psi
(bar)
90
06 (6)

Rev.0208

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Directional Valves, Mechanically Operated.

VDSD-10A

VDP-32

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL SPOOL TYPE,
DIRECTIONAL SPOOL TYPE,
DIRECT ACTING EXTERNAL PILOT ACTING
DIRECT EXTERNAL VENT PILOT EXTERNAL VENT
EXTERNAL
COMMON CAVITY COMMON CAVITY
VDSD-10A VDSD-10A
SIZE 10 04.77.22 - XSIZE
- 8510
-Z 04.77.22 - X - 85 - Z

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: 13 gpm (50 l/min)

3 3
Int. leakage ave. : 1.5 in /min (25 cm /min)

Pilot displacement 3 3
0.02 in (0.28 cm )
volume:

Cavity : CA-10A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01$«
Flow is allowed bi-directionally between 2 and 3 until pressure at 1 rises to overcome
the spring bias against the spool. When this bias pressure is surpassed, the spool External seal kit : see page A11.011
shifts, blocking flow at both 2 and 3. The spring chamber is sealed and vented to
atmosphere, allowing consistent shifting with only spring bias pressure independent
Installation torque : 30-35 ft-lb (41-47 Nm)
of conditions at 2 or 3.

Weight: 0.441 lbs (0.200 Kg)

X O-RING ON PILOT PISTON

00 No O-Ring

10 With O-Ring

SPRINGS
Z Setting
psi
(bar)
80 r20%
05 (5.5 r20%)
167 r10%
11 (11.5 r10%)

Rev.1106 Page. AA6.070

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL CONTROL VALVES
HYDRAULIC AUTOMATIC SWITCHING
SPOOL 3-WAY 2-POSITION CARTRIDGE STYLE
VDP-32 OD.71.01.51 - Z

Hex. 24
Torque 39-51 Nm

TECHNICAL DATA
Maximum Operating
315 bar
Pressure
Rated Flow 30 l/min

Cavity - Tooling (051-E) page 7.01.110

Weight 0.195 kg

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.050


Filtration : 25 Pm nominal or
unrestricted
better
Pressure settings different from standard have
to be specified when ordering.
350 8

300 7
PRESSURE - ǻp (bar)

PRESSURE - ǻp (bar)

250 6
5
200
4
150
3
100
2
50 1
0 0
0 5 10 15 20 25 30 35
FLOW - Q (l/min)

SWITCHING PRESSURE
bar
Z
Adj. pressure
Standard setting
range

01 3-25 5
02 20-60 35
04 70-100 90

Rev.03.03 2.43.010.G

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Shuttle Valves

VFC

SELB-08A

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SHUTTLE

VFC 05.99.05.00 - Y

TECHNICAL DATA

Operating pressure: up to 210 bar (3000 psi)

Max flow: 50 l/min (13 gpm)

Aluminium body
NOTE: aluminium bodies are often strong enough for operating
pressures exceeding 210 bar (3000 psi), depending from the
fatigue life expected in the specific application. If in doubt,
consult our Service Network.

Weigth: 0.17 kg (0.4 lbs)


Single ball shuttle valve with 3 ports for in-line plumbing: when the ports V1 and V2 are
connected to 2 work lines, the valve delivers the highest of the 2 pressures to the common
port C. The single ball allows for the decay of the pressure signal when both work ports
drop to a lower pressure level.

PORT SIZE
Y
V1-V2-C
09 G 1/4

Bosch Rexroth Oil Control S.p.a RE 00171/02.07

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Solenoide Valves

VED-8I-32- VEI-8A-2A-10A-
06-SE NC-S-NSS

VED-8I-32- VEI-8A-2A-10A-
06-SI NC-S-X-NSS

VED-8I-32- VEI-8A-2A-12-
06-NC NA-S-NSS

VED-8I-42- VEI-8A-2A-12-
06-CA NC-S-X-NSS

VEI-8A-2A-12A-
VED-8I-43-
NA-S-NSS
06-ABT

VEI-8A-2A-06- VEI-8A-2T-06-
NA-S-NSS NA-S-NSS

VEI-8A-2T-06-
VEI-8A-2A-06- NC-S-NSS
NC-S-X-NSS

VEI-8I-2A-06-
VEI-8A-2A-09- NC-S-NSS
NA-S-NSS

VEI-8I-2A-06-
VEI-8A-2A-09-
NC-S1-NSS
NC-S-X-NSS

VEI-8A-2A-10A- VEI-8I-2A-06-
NA-S-NSS NC-S1-NSS, N9

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL POPPET TYPE,
DIRECTIONAL POPPET TYPE,
SHUTTLE SHUTTLE
COMMON CAVITY COMMON CAVITY
SELB-08A SIZE 08
SELB-08A 04.94.05.00.56.00
SIZE 08 04.94.05.00.56.00

TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)

Max. flow: see performance graph

Nominal size DN 3

Cavity : CA-08A-3N (see page CT.A.003.U)

/LQHERGLHVVHHSDJH01$«

External seal kit : see page A11.011


The single ball shuttle allows flow from the higher pressure of two work ports 1 and 3
to the 2 port. Installation torque : 25-30 ft-lb (34-41 Nm)

Weight: 0.132 lbs (0.060 Kg)

Rev.0606

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-SE
VED-8I-32-06-SE SIZE 08 OD.13.10.51
OD.13.10.51 -- Y
Y -- 00

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm

TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure

Rated Flow 3 gpm (10 l/min)

Cavity - Tooling (CA-08A-3N) page CT.A.003.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage at 3000 psi Max.2.5 (Max.40


(210 bar) with 46 cSt oil in³/min cm³/min)
Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

30 Standard

40 Knob Style Manual Override

Rev.06.05 1.31.050.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-SI
VED-8I-32-06-SI SIZE 08 OD.13.11.51
OD.13.11.51 -- Y
Y -- 00
00

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm

TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure

Rated Flow 3 gpm (10 l/min)

Cavity - Tooling (CA-08A-3N) page CT.A.003.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Port 1 can be pressurized but is not intended to be used as inlet port. Testing Conditions - Seals page 7.01.040

Internal Leakage(2 Ź 3) Max.2.5 (Max.40


at 210 bar with 46 cSt oil in³/min cm³/min)
Internal Leakage(2 Ź 1) Max.9.8 (Max.160
at 210 bar with 46 cSt oil in³/min cm³/min)
Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

30 Standard

40 Knob Style Manual Override

Rev.06.05 1.31.100.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-NC
VED-8I-32-06-NC SIZE 08 OD.13.20.51
OD.13.20.51 -- Y
Y -- 00

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm

TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure

Rated Flow 3 gpm (10 l/min)

Cavity - Tooling (CA-08A-3N) page CT.A.003.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage at 3000 psi Max.2.5 (Max.40


(210 bar) with 46 cSt oil in³/min cm³/min)
Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

30 Standard

40 Knob Style Manual Override

Rev.06.05 1.31.150.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 4-WAY 2-POSITION
SPOOL 4-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-42-06-CA
VED-8I-42-06-CA SIZE 08 OD.14.40.58
OD.14.40.58 -- YY -- 00
00

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm

TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure

Rated Flow 3 gpm (10 l/min)

Cavity - Tooling (CA-08A-4N) page CT.A.004.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage at 3000 psi Max.2.5 (Max.40


(210 bar) with 46 cSt oil in³/min cm³/min)
Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

30 Standard

40 Knob Style Manual Override

Rev.06.05 1.41.050.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 4-WAY 3-POSITION
SPOOL 4-WAY 3-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-43-06-ABT
VED-8I-43-06-ABT SIZE 08 OD.14.32.58
OD.14.32.58 -- YY -- 00
00

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm
TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure

Rated Flow 3 gpm (10 l/min)

Cavity - Tooling (CA-08A-4N) page CT.A.004.U

Line bodies page MN2.A…

Weight 0.397 lbs (0.180 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage at 3000 psi Max.7.3 (Max.120


(210 bar) with 46 cSt oil in³/min cm³/min)
Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

44 Standard

Rev.06.05 1.43.150.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-06-NA-S-NSS
VEI-8A-2A-06-NA-S-NSS SIZE 08 OD.15.06.18
OD.15.06.18 -- Y
Y -- S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 11 gpm (40 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.06.05 1.12B.060.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED - EXTRA
2-WAY SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
017-E OD.15.05.17017-E
VEI-8A-2A-09-NC-S-X-NSSVEI-8A-2A-09-NC-S-X-NSS - Y - S8 OD.15.05.17 - Y - S8
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (017-E ) page CT.S.005.U

/LQHERGLHV SDJH016«

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040


Filtration : 25 Pm nominal or
page 7.01.050
better
Minimum Voltage Required 90% of nominal
Coils must be ordered
page 1.71.042
separately
Mounting Position unrestricted

The only difference between this valve and the


standard model is a spring placed between pilot
section and poppet.
This design allows faster response times with very
small flow or even virtually zero flow.
A pressure of approximately 58 psi (4 bar) is
required to open the main poppet.

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.10.08 1.11B.465.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-10A-NA-S-NSS
VEI-8A-2A-10A-NA-S-NSS SIZE 10 OD.15.06.36
OD.15.06.36 -- YY -- S0
S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. 1.06 / 32.5-41.3 ft-lb


Hex. (27) / (44-56) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (CA-10A-2N) page CT.A.001.U

Line bodies page MN1.A…

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.06.05 1.16B.460.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED - EXTRA
2-WAY SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
017-E OD.15.05.17017-E
VEI-8A-2A-09-NC-S-X-NSSVEI-8A-2A-09-NC-S-X-NSS - Y - S8 OD.15.05.17 - Y - S8
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (017-E ) page CT.S.005.U

/LQHERGLHV SDJH016«

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040


Filtration : 25 Pm nominal or
page 7.01.050
better
Minimum Voltage Required 90% of nominal
Coils must be ordered
page 1.71.042
separately
Mounting Position unrestricted

The only difference between this valve and the


standard model is a spring placed between pilot
section and poppet.
This design allows faster response times with very
small flow or even virtually zero flow.
A pressure of approximately 58 psi (4 bar) is
required to open the main poppet.

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.10.08 1.11B.465.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-10A-NA-S-NSS
VEI-8A-2A-10A-NA-S-NSS SIZE 10 OD.15.06.36
OD.15.06.36 -- YY -- S0
S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. 1.06 / 32.5-41.3 ft-lb


Hex. (27) / (44-56) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (CA-10A-2N) page CT.A.001.U

Line bodies page MN1.A…

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.06.05 1.16B.460.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 10 OD.15.05.36SIZE
VEI-8A-2A-10A-NC-S-NSS VEI-8A-2A-10A-NC-S-NSS - Y -10
S0 OD.15.05.36 - Y - S0
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (CA-10A-2N) page CT.A.001.U

/LQHERGLHV SDJH01$«

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.02.07 1.15B.460.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVESSOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY
- EXTRA SPRING CLOSED - EXTRA SPRING
NORMALLY
COMMON CAVITY COMMON CAVITY
SIZE 10 OD.15.05.36SIZE
VEI-8A-2A-10A-NC-S-X-NSSVEI-8A-2A-10A-NC-S-X-NSS - Y -10
S8 OD.15.05.36 - Y - S8
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 19 gpm (70 l/min)

Cavity - Tooling (CA-10A-2N) page CT.A.001.U

/LQHERGLHV SDJH01$«

Weight 0.485 lbs (0.220 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040


Filtration : 25 Pm nominal or
page 7.01.050
better
Minimum Voltage Required 90% of nominal
Coils must be ordered
page 1.71.042
separately
Mounting Position unrestricted

The only difference between this valve and the


standard model is a spring placed between pilot
section and poppet.
This design allows faster response times with very
small flow or even virtually zero flow.
A pressure of approximately 58 psi (4 bar) is
required to open the main poppet.

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.02.07 1.15B.465.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
OPEN 2-WAY NORMALLY OPEN
SPECIAL CAVITY SPECIAL CAVITY
021-E OD.15.06.21021-E
VEI-8A-2A-12-NA-S-NSS VEI-8A-2A-12-NA-S-NSS - Y - S0 OD.15.06.21 - Y - S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. 1.50 / 59.0-73.8 ft-lb


Hex. (38) / (80-100) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 39 gpm (150 l/min)

Cavity - Tooling (021-E) page CT.S.006.U

Line bodies page MN2.S…

Weight 0.772 lbs (0.350 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.09.05 1.12B.660.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY
- EXTRA SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
OD.15.05.21021-E
VEI-8A-2A-12-NC-S-X-NSS
VEI-8A-2A-12-NC-S-X-NSS 021-E - Y - S8 OD.15.05.21 - Y - S8
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 39 gpm (150 l/min)

Cavity - Tooling (021-E) page CT.S.006.U

/LQHERGLHV SDJH016«

Weight 0.772 lbs (0.350 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040


Filtration : 25 Pm nominal or
page 7.01.050
better
Minimum Voltage Required 90% of nominal
Coils must be ordered
page 1.71.042
separately
Mounting Position unrestricted

The only difference between this valve and the


standard model is a spring placed between pilot
section and poppet.
This design allows faster response times with very
small flow or even virtually zero flow.
A pressure of approximately 44 psi (3 bar) is
required to open the main poppet.

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.02.07 1.11B.665.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-12A-NA-S-NSS
VEI-8A-2A-12A-NA-S-NSS SIZE 12 OD.15.06.89
OD.15.06.89 -- YY -- S0
S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. 1.26 / 39.8-48.7 ft-lb


Hex. (32) / (54-66) Nm

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 39 gpm (150 l/min)

Cavity - Tooling (CA-12A-2N) page CT.A.001.U

Line bodies page MN1.A…

Weight 0.772 lbs (0.350 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.06.05 1.16B.660.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY DOUBLE
POPPET 2-WAY DOUBLE LOCK
LOCK NORMALLY
NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2T-06-NA-S-NSS
VEI-8A-2T-06-NA-S-NSS SIZE 08 OD.15.32.18
OD.15.32.18 -- YY -- S0
S0
PATENT PENDING

2.2-3.0 ft-lb
(3-4) Nm

Coil S8-356

Hex. .94 / 28.8-37.6 ft-lb


Hex. (24) / (39-51) Nm TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 11 gpm (40 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

Line bodies page MN2.A…

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

1A Standard

Push Style Manual


1B Override

Push and Twist Style


1C Manual Override

Rev.06.05 1.14B.060.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY DOUBLE LOCK NORMALLY
POPPET CLOSEDLOCK NORMALLY CLOSED
2-WAY DOUBLE
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.31.18SIZE
VEI-8A-2T-06-NC-S-NSSVEI-8A-2T-06-NC-S-NSS - Y -08
S0 OD.15.31.18 - Y - S0
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 11 gpm (40 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

/LQHERGLHV SDJH01$«

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 Pm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

3A Standard

3D Knob Style Manual Override

Rev.02.07 1.13B.060.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.05.18SIZE
VEI-8I-2A-06-NC-S-NSS VEI-8I-2A-06-NC-S-NSS - Y -08
S0 OD.15.05.18 - Y - S0
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 8 gpm (30 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

/LQHERGLHV SDJH01$«

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 µm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

3I Standard

3M Knob Style Manual Override

Rev.01.07 1.11B.050.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.01.18SIZE
VEI-8I-2A-06-NC-S1-NSSVEI-8I-2A-06-NC-S1-NSS - Y -08
S0 OD.15.01.18 - Y - S0
PATENT PENDING

TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)

Rated Flow 8 gpm (30 l/min)

Cavity - Tooling (CA-08A-2N) page CT.A.001.U

/LQHERGLHV SDJH01$«

Weight 0.286 lbs (0.130 kg)

Fluids - Temperatures page 7.01.040

Testing Conditions - Seals page 7.01.040

Internal Leakage page 7.01.040

Filtration : 25 µm nominal or
page 7.01.050
better

Minimum Voltage Required 90% of nominal

Coils must be ordered


page 1.71.042
separately

Mounting Position unrestricted

Y ORDERING OPTIONS

3I Standard

3M Knob Style Manual Override

Rev.01.07 1.11B.030.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
CONTINUOUS DUTY COILSCONTINUOUS
- ED 100% DUTY COILS - ED 100%

OD.02.17
S8-356 SERIES - CLASS H S8-356 SERIES - CLASS H -X-Y-Z OD.02.17 - X - Y - Z
TECHNICAL DATA
General coil information page 7.01.010

S8-H S8-A S8-G Weight 0.397 lbs (0.180 kg)

DIN 43650 - ISO 4400 AMP JUNIOR SINGLE LEAD


Encapsulating material IXEF

HEAT INSULATION
356 qF (180 qC)
CLASS H
-86 +140 (-30 +60
Ambient temperature range
°F °C)

Available on request : Different Voltages - Different


connectors mounted on single lead.

Inlet voltage fluctuations must not exceed r 10% of


nominal voltage to obtain correct operation and long
life of coils.

X Y Connections Circuit Voltage

01 30 DIN 43650 - ISO 4400 Standard DC-RAC


07 30 AMP JUNIOR Standard DC only Length
11.8 inches (300 mm)
0G 03 SINGLE LEAD Standard DC only Ext. diameter
14 30 DIN 43650 - ISO 4400 Bidirectional Diode DC only 0.25 inches (6.3 mm)
External and Internal Sheath
15 30 AMP JUNIOR Bidirectional Diode DC only Silicone rubber
0H 03 SINGLE LEAD Bidirectional Diode DC only

Voltage Resistance Power Current 'T


V ȍ (±7%) W A °F (°C)
Z 1 hour energized at
Nominal Ta = 68-77 °F (20-25 °C) Cold Coil Cold Coil Hot Coil Ta = 68-77 °F (20-25 °C)
Nominal Voltage

OB 12 DC 7.4 20 1.62 1.19


OC 24 DC 28.5 20 0.85 0.61
OV 24 RAC 20
OW 110 RAC 20 221-230 (105-110)
OZ 220 RAC 20
OG 14 DC 20
AC 26 DC 34.3 20 0.76 0.54
Rev.06.05 1.71.042.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
CONTINUOUS DUTY COILS -- ED
CONTINUOUS DUTY COILS ED 100%
100%

S8-356SERIES
S8-356 SERIES--CLASS
CLASSHH OD.02.17
OD.02.17 -- X
X -- Y
Y -- Z
TECHNICAL DATA
General coil information page 7.01.010

S8-DTL S8-DTV S8-ASV Weight 0.397 lbs (0.180 kg)

DEUTSCH DT04-2P-L DEUTSCH DT04-2P-V AMP SUPERSEAL-V


Encapsulating material IXEF

Protection IP 69K DIN 40050 part 9


These coils have passed the
THERMAL SHOCK DUNK
TEST, see page 7.01.010
HEAT INSULATION
356 qF (180 qC)
CLASS H
-86 +140 (-30 +60
Ambient temperature range
°F °C)

Available on request : Different Voltages - Different


connectors mounted on single lead.

Inlet voltage fluctuations must not exceed r 10% of


nominal voltage to obtain correct operation and long
life of coils.

X Y Connections Circuit Voltage

20 30 DEUTSCH DT04-2P-L Standard DC only


20 3P DEUTSCH DT04-2P-V Standard DC only
30 3P AMP SUPERSEAL-V Standard DC only
22 30 DEUTSCH DT04-2P-L Bidirectional Diode DC only
22 3P DEUTSCH DT04-2P-V Bidirectional Diode DC only
32 3P AMP SUPERSEAL-V Bidirectional Diode DC only

Voltage Resistance Power Current 'T


V ȍ (±7%) W A °F (°C)
Z 1 hour energized at
Nominal Ta = 68-77 °F (20-25 °C) Cold Coil Cold Coil Hot Coil Ta = 68-77 °F (20-25 °C)
Nominal Voltage

OB 12 DC 7.4 20 1.62 1.19


OC 24 DC 28.5 20 0.85 0.61
AC 26 DC 34.3 20 0.76 0.54
221-230 (105-110)

Rev.06.05 1.71.043.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
STANDARD
COMMON CAVITY COMMON CAVITY

2 WAY ALUMINIUM SIZE


2 WAY 08
ALUMINIUM SIZE 08

CAVITY CA-08A-2N

Dimensions on page CT.A.001.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
0.331
OC.10.09.009 G 1/4
(0.150)
0.331
OC.10.09.004 G 3/8
(0.150)

FEATURES
3600 psi
MAX. PRESSURE Standard manifolds in high-strength aluminum
(250 bar) for working pressures up to 3600 psi (250 bar).

Rev.07.06 MN2.A.001.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
COMMON CAVITY
COMMON CAVITY

22WAY
WAYSTEEL
STEEL SIZE
SIZE 08
08

CAVITY CA-08A-2N

Dimensions on page CT.A.001.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
0.992
OC.10.09.067 G 1/4
(0.450)
0.992
OC.10.09.066 G 3/8
(0.450)

FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.

Rev.05.05 MN2.A.002.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
STANDARD
COMMON CAVITY COMMON CAVITY

SIZE
3 WAY 4 WAY ALUMINIUM3 WAY 08 ALUMINIUM
4 WAY SIZE 08

CAVITY CA-08A-3N

Dimensions on page CT.A.003.U

ORDERING PORTS WEIGHT


CODE
P-C-C1/T Lbs (Kg)
0.331
OC.10.09.042 G 1/4
(0.150)
0.331
OC.10.09.048 G 3/8
(0.150)

CAVITY CA-08A-4N

Dimensions on page CT.A.004.U

ORDERING PORTS WEIGHT


CODE
A-B-P-T Lbs (Kg)
0.331
OC.10.09.047 G 1/4
(0.150)

0.331
OC.10.09.046 G 3/8
(0.150)

FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).

Rev.07.06 MN2.A.003.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD
STANDARD MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
COMMON CAVITY
COMMON CAVITY

33 WAY
WAY 4
4 WAY
WAY ALUMINIUM
ALUMINIUM SIZE
SIZE 10
10

CAVITY CA-10A-3N

Dimensions on page CT.A.003.U

ORDERING PORTS WEIGHT


CODE
P-C-C1/T Lbs (Kg)
0.375
OC.10.09.116 G 1/4
(0.170)
0.375
OC.10.09.115 G 3/8
(0.170)

CAVITY CA-10A-4N

Dimensions on page CT.A.004.U

ORDERING PORTS WEIGHT


CODE
A-B-P-T Lbs (Kg)
0.375
OC.10.09.117 G 1/4
(0.170)

0.375
OC.10.09.118 G 3/8
(0.170)

FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).

Rev.07.06 MN2.A.004.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
SPECIAL CAVITY SPECIAL CAVITY

2 WAY ALUMINIUM 2 WAY ALUMINIUM

CAVITY 017-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
0.441
OC.10.09.015 G 1/2
(0.200)

0.441
OC.10.09.012 G 3/4
(0.200)

CAVITY 021-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
1.367
OC.10.09.017 G 3/4
(0.620)
1.367
OC.10.09.019 G1
(0.620)

FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).

Rev.07.06 MN2.S.001.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
SPECIAL CAVITY SPECIAL CAVITY

2 WAY ALUMINIUM 2 WAY ALUMINIUM

CAVITY 019-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
0.331
OC.10.09.103 G 1/4
(0.150)
0.331
OC.10.09.054 G 3/8
(0.150)

CAVITY 004
Dimensions on page CT.S.001.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
2.646
OC.10.09.040 G1
(1.200)

2.646
OC.10.09.041 G 1-1/4
(1.200)

CAVITY 081-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-P-T Lbs (Kg)
0.397
OC.10.09.128 G 1/4
(0.180)

FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).

Rev.07.06 MN2.S.003.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
SPECIAL CAVITY
SPECIAL CAVITY

22WAY
WAYSTEEL
STEEL

CAVITY 017-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
1.984
OC.10.09.074 G 1/2
(0.900)

1.984
OC.10.09.073 G 3/4
(0.900)

CAVITY 021-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
2.866
OC.10.09.075 G 3/4
(1.300)
2.866
OC.10.09.076 G1
(1.300)

FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.

Rev.05.05 MN2.S.002.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
SPECIAL CAVITY
SPECIAL CAVITY

22WAY
WAYSTEEL
STEEL

CAVITY 019-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
0.992
OC.10.09.102 G 1/4
(0.450)
0.992
OC.10.09.101 G 3/8
(0.450)

CAVITY 004
Dimensions on page CT.S.001.U

ORDERING PORTS WEIGHT


CODE
A-B Lbs (Kg)
7.716
OC.10.09.122 G1
(3.500)

7.716
OC.10.09.056 G 1-1/4
(3.500)

CAVITY 081-E
Dimensions on page CT.S.005.U

ORDERING PORTS WEIGHT


CODE
A-P-T Lbs (Kg)
1.191
OC.10.09.162 G 1/4
(0.540)

FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.

Rev.05.05 MN2.S.004.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY

CA-xxx-2N
CA-xxx-2N

CAVITY DIMENSIONS (mm) ORDERING CODES


A B C D E F G H I L M N P Aluminium Steel
G 1/4 50 50 30 21 12 35 9 15 7 03.30.05.168 03.30.05.169
G 3/8 50 50 30 21 12 35 9 15 7 03.30.05.170 03.30.05.171
CA-08A-2N

7/16-20 50 50 30 21 12 35 9 15 7 03.30.05.172 03.30.05.173


9/16-18 50 50 30 21 12 35 9 15 7 03.30.05.174 03.30.05.175

G 3/8 60 60 35 25 15 45 7 19 7 03.30.05.176 03.30.05.177


G 1/2 60 60 35 25 15 45 7 19 7 03.30.05.178 03.30.05.179
CA-10A-2N

G 3/4 60 70 40 30 15 55 9 20 9 03.30.05.226
9/16-18 60 60 35 25 15 45 7 19 7 03.30.05.180 03.30.05.181
3/4-16 60 60 35 25 15 45 7 19 7 03.30.05.182 03.30.05.183
7/8-14 60 60 35 25 15 45 7.5 19 7 03.30.05.247 03.30.05.248
G 1/2 75 80 40 35 20 60 10 26.5 9 03.30.05.228 03.30.05.229
G 3/4 75 80 40 35 20 60 10 26.5 9 03.30.05.289 03.30.05.290
CA-12A-2N

G 3/4 80 80 50 32 22 60 10 26 9 03.30.05.166 03.30.05.184


G1 80 90 50 37 22 60 20 26 9 03.30.05.216 03.30.05.215
CA-16A-2N

1-1/16-12 80 80 50 32 22 60 10 26 9 03.30.05.185 03.30.05.186


CA-20A-2N

Available on request Ports ISO 6149 and JIS B 2351-90 type 0

Rev.1205 Page MN1.A.001.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 1) MANIFOLDS (SECTION 1)
STANDARD
COMMON CAVITY COMMON CAVITY

CA-xxx-3C CA-xxx-3C

CAVITY DIMENSIONS (mm) ORDERING CODES


A B B1 C D E F G H I L M P Aluminium Steel
G 3/8 G 1/4 60 60 30 30 15 45 7.5 13 27 7 03.30.05.187 03.30.05.188
9/16-18 7/16-20 60 60 30 30 15 45 7.5 13 27 7 03.30.05.189 03.30.05.190
CA-08A-3C

G 3/8 G 1/4 70 60 35 30 15 45 7.5 15 32 7 03.30.05.192


G 1/2 G 1/4 70 70 35 32 15 55 7.5 15 32 7 03.30.05.193 03.30.05.194
CA-10A-3C

9/16-18 7/16-20 70 70 35 32 15 55 7.5 15 32 7 03.30.05.195 03.30.05.196


7/8-14 9/16-18 70 70 35 32 15 55 7.5 15 32 7 03.30.05.243 03.30.05.244

G 1/2 G 1/4 80 75 40 35 15 55 10 24 42 7 03.30.05.217 03.30.05.218


7/8-14 9/16-18 80 75 40 35 15 55 10 24 42 7 03.30.05.245 03.30.05.246
CA-12A-3C

G1 G 1/4 90 90 50 40 22 70 10 18.5 39 9 03.30.05.167 03.30.05.197


1-5/16-12 7/16-20 90 90 50 40 22 70 10 18.5 39 9 03.30.05.198 03.30.05.199
CA-16A-3C

G 1-1/4 G 1/4 110 100 60 45 25 75 12.5 21 51 11 03.30.05.200 03.30.05.201


1-5/8-12 7/16-20 110 100 60 45 25 75 12.5 21 51 11 03.30.05.202 03.30.05.203
CA-20A-3C

Available on request Ports ISO 6149 and JIS B 2351-90 type 0

Rev.0605 Page MN1.A.002.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY

CA-xxx-3N

CAVITY DIMENSIONS (mm) ORDERING CODES


A B C D E F G H I L M N P Aluminium Steel
CA-08A-3N

G 3/8 70 60 35 30 15 45 7.5 18 34.5 7 03.30.05.204 03.30.05.205


9/16-18 70 60 35 30 15 45 7.5 18 34.5 7 03.30.05.206 03.30.05.207
CA-10A-3N
CA-12A-3N

G 3/4 100 90 50 45 20 60 15 26 54.5 10.5 03.30.05.232 03.30.05.233


CA-16A-3N
CA-20A-3N

Available on request Ports ISO 6149 and JIS B 2351-90 type 0

Rev.0605 Page MN1.A.003.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 1) MANIFOLDS (SECTION 1)
STANDARD
COMMON CAVITY COMMON CAVITY

CA-xxx-4N CA-xxx-4N

CAVITY DIMENSIONS (mm) ORDERING CODES


A B C D E F G H I L M N P Aluminium Steel
CA-08A-4N

G 3/8 85 60 35 30 15 45 7.5 19 35 51 7 03.30.05.211 03.30.05.209


9/16-18 85 60 35 30 15 45 7.5 19 35 51 7 03.30.05.249 03.30.05.250
CA-10A-4N
CA-12A-4N

G 3/4 130 90 50 45 20 60 15 26 54.5 83 10.5 03.30.05.230 03.30.05.231


1-1/16-12 125 90 50 45 15 60 15 26 54.5 83 9 03.30.05.251 03.30.05.252
CA-16A-4N
CA-20A-4N

Available on request Ports ISO 6149 and JIS B 2351-90 type 0

Rev.0605 Page MN1.A.004.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY

CA-xxx-4N

CAVITY DIMENSIONS (mm) ORDERING CODES


A B C D E F G H I L M N P Aluminium Steel
CA-08A-4N

G 3/8 75 60 35 30 15 50 10 19 35 51 7 03.30.05.210
CA-10A-4N
CA-12A-4N

1-1/16-12 115 90 50 45 15 80 15 26 54.5 83 9 03.30.05.253 03.30.05.254


CA-16A-4N
CA-20A-4N

Available on request Ports ISO 6149 and JIS B 2351-90 type 0

Rev.0605 Page MN1.A.005.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIESSTANDARD
- TOOLS CAVITIES - TOOLS

TOOLS ORDERING CODE


(ALUMINIUM/STEEL *)

DRILL

Ø G1 Ø G1 Ø G1 Ø G1 Ø G1

FORM DRILL

P-CA-08A-2N P-CA-10A-2N P-CA-12A-2N P-CA-16A-2N P-CA-20A-2N

FORM REAMER

A-CA-08A-2N A-CA-10A-2N A-CA-12A-2N A-CA-16A-2N A-CA-20A-2N

PLUG TAP

M-CA-08A M-CA-10A M-CA-12A M-CA-16A M-CA-20A

* NOTE: Special heavy duty tools are available upon request, for steel drilling.

inches (mm)

Rev.0605 Page CT.A.001.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIESSTANDARD
- TOOLS CAVITIES - TOOLS

TOOLS ORDERING CODE


(ALUMINIUM/STEEL *)

DRILL

Ø G1 Ø G1 Ø G1 Ø G1 Ø G1

FORM DRILL

P-CA-08A-3N P-CA-10A-3N P-CA-12A-3N P-CA-16A-3N P-CA-20A-3N

FORM REAMER

A-CA-08A-3N A-CA-10A-3N A-CA-12A-3N A-CA-16A-3N A-CA-20A-3N

PLUG TAP

M-CA-08A M-CA-10A M-CA-12A M-CA-16A M-CA-20A

* NOTE: Special heavy duty tools are available upon request, for steel drilling.

inches (mm)

Rev.0605 Page CT.A.003.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIES
STANDARD CAVITIES - TOOLS

TOOLS ORDERING CODE


(ALUMINIUM/STEEL *)

DRILL

Ø G2 Ø G2 Ø G2 Ø G2 Ø G2

FORM DRILL

P-CA-08A-3C P-CA-10A-3C P-CA-12A-3C P-CA-16A-3C P-CA-20A-3C

FORM REAMER

A-CA-08A-3C A-CA-10A-3C A-CA-12A-3C A-CA-16A-3C A-CA-20A-3C

PLUG TAP

M-CA-08A M-CA-10A M-CA-12A M-CA-16A M-CA-20A

* NOTE: Special heavy duty tools are available upon request, for steel drilling.

inches (mm)

Rev.0605 Page CT.A.002.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIES - TOOLS
STANDARD

TOOLS ORDERING CODE


(ALUMINIUM/STEEL *)

DRILL

Ø G1 Ø G1 Ø G1 Ø G1 Ø G1

FORM DRILL

P-CA-08A-4N P-CA-10A-4N P-CA-12A-4N P-CA-16A-4N P-CA-20A-4N

FORM REAMER

A-CA-08A-4N A-CA-10A-4N A-CA-12A-4N A-CA-16A-4N A-CA-20A-4N

PLUG TAP

M-CA-08A M-CA-10A M-CA-12A M-CA-16A M-CA-20A

* NOTE: Special heavy duty tools are available upon request, for steel drilling.

inches (mm)

Rev.0206 Page CT.A.004.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES

003 004

005 006

008 009

General tolerance : ± 0.3mm

Rev.1005 Page CT.S.001.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL
SPECIAL CAVITIES
CAVITIES

033 059

063 065

072 137

General tolerances : ± 0.3mm


Rev.0605 Page CT.S.002.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES

348 416

625 690

730 730-A

General tolerances : ± 0.3mm


Rev.0905 Page CT.S.003.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES
SPECIAL CAVITIES

771 808

869 870

871

General tolerances : ± 0.3mm


Rev.0905 Page CT.S.004.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES

CA-07A-3N CC063A-01

CD072A-01 CD073A-01

General tolerances : ± 0.3mm


Rev.0607 Page CT.S.005.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL
SPECIAL CAVITIES
CAVITIES

017-E 019-E

021-E 081-E

General tolerance : ± 0.3mm

Rev.0905 Page CT.S.006.U

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Preferred
Group BROC Catalog Code BROC Ident Denomination Rexroth Code
Type

04.11.49.03.56.10.000 relief, direct acting guided poppet type, common cavity R901113599 X
VSBN-08A 04.11.49.03.56.20.000 relief, direct acting guided poppet type, common cavity R901097728 X
04.11.49.03.56.35.000 relief, direct acting guided poppet type, common cavity R901091914 X
04.11.55.03.85.10.000 relief, direct acting guided poppet type, common cavity R901113609 X
VSBN-10A 04.11.55.03.85.20.000 relief, direct acting guided poppet type, common cavity R901113610 X
04.11.55.03.85.35.000 relief, direct acting guided poppet type, common cavity R901115702 X
04.11.56.03.85.10.000 relief, direct acting guided poppet type, common cavity R901113622 X
VSBG-10A 04.11.56.03.85.20.000 relief, direct acting guided poppet type, common cavity R901113624 X
04.11.56.03.85.35.000 relief, direct acting guided poppet type, common cavity R901113626 X
04.11.59.03.85.10.000 relief, bidirectional, direct acting poppet type differential area, common cavity R901109725
Pressure Control Valves VSNG - 10A
04.11.59.03.85.20.000 relief, bidirectional, direct acting poppet type differential area, common cavity R901109726
04.12.08.03.85.20.000 relief, pilot operated, spool type, common cavity R901097722
VSPN - 10A
04.12.08.03.85.35.000 relief, pilot operated, spool type, common cavity R901104103
04.13.05.03.85.10.000 pilot operated sequence valve, spool type, external drain, common cavity R901106472 X
VSPY - 10A
04.13.05.03.85.20.000 pilot operated sequence valve, spool type, external drain, common cavity R901097730
VRPP - 10A 04.93.06.03.85.10.000 pressure reducing, pilot operated, spool type, common cavity R901104112 X
VRPX - 10A 04.93.07.03.85.10.000 pressure reducing and relieving, pilot operated spool type, common cavity R901104118
04.95.04.03.85.02.00A pressure reducing and relieving, direct acting spool type, common cavity R901109740
VRPR - 10A 04.95.04.03.85.04.00A pressure reducing and relieving, direct acting spool type, common cavity R901102333 X
04.95.04.03.85.08.00A pressure reducing and relieving, direct acting spool type, common cavity R901109742 X
0T.F4.01.03.03.00.000 hose burst R901127828
0T.F4.01.03.09.00.000 hose burst R931000021
Special Valves VPN1
0T.F4.01.03.04.00.000 hose burst R901161819
0T.F4.01.03.02.00.000 hose burst R931000017
0T.U5.01.00.03.00.000 check, poppet type R901087794
VUH1
0T.U5.01.00.02.00.000 check, poppet type R901064101
VSON - 08A 04.33.06.00.56.00.000 pilot operated check, common cavity R901106627 X
VSON - 10A 04.33.05.00.85.00.000 pilot operated check, common cavity R901106629 X
VSON - 12A 04.33.07.00.57.00.000 pilot operated check, common cavity R901092653 X
VSON - 16A 04.33.08.00.27.00.000 pilot operated check, common cavity R901106635
Check Valves 04.31.20.00.56.00.000 check poppet type, 1 bar cracking, common cavity R901007308 X
VUCN - 08A
04.31.20.00.56.05.000 check poppet type, 5 bar cracking, common cavity R901106550 X
04.31.23.00.85.00.000 check poppet type, 1 bar cracking, common cavity R901106596 X
VUCN - 10A
04.31.23.00.85.05.000 check poppet type, 5 bar cracking, common cavity R901106601 X
04.31.28.00.57.00.000 check poppet type, 1 bar cracking, common cavity R901106613 X
VUCN - 12A
04.31.28.00.57.05.000 check poppet type, 5 bar cracking, common cavity R901106614
VUCN - 16A 04.31.25.00.27.00.000 check poppet type, common cavity R901106616
04.52.20.03.56.20.000 counterbalance, std. guided poppet type, common cavity R901095960
VBSN - 08AA
04.52.20.03.56.35.000 counterbalance, std. guided poppet type, common cavity R901095961
04.52.31.03.85.35.000 counterbalance, std. poppet type, diff area, 3:1, 140 - 350bar, common cavity R901096037
VBSN - 10A
04.52.31.03.85.20.000 counterbalance, std. poppet type, diff area, 3:1, 70 - 210bar, common cavity R901096029 X
Counterbalance Valves
04.52.28.03.57.35.000 counterbalance, std. poppet type, diff area, 4:1, 140 - 350bar, common cavity R901096044
VBSN - 12A
04.52.28.03.57.20.000 counterbalance, std. poppet type, diff area, 4:1, 70 - 210bar, common cavity R901096043 X
04.52.29.03.27.35.000 counterbalance, std. poppet type, diff area, 4:1, 140 - 350bar, common cavity R901096048
VBSN - 16A
04.52.29.03.27.20.000 counterbalance, std. poppet type, diff area, 4:1, 70 - 210bar, common cavity R901096047
04.01.02.03.56.00.000 needle restrictor with free reverse flow, common cavity R901109368 X
STVU - 08A
04.01.02.04.56.00.000 needle restrictor, free reverse flow, common cavity R901109839
VRFB-10A 04.02.02.04.85.40.000 flow control, 2-way pressure compensated, fully adjustable, common cavity R901095981 X
flow control, 3-way pressure compensated, combination type fully adjustable, common
VRFD-10 04.04.02.04.85.40.000 R901106675 X
cavity
04.05.01.00.85.16.000 flow divider and combiner, common cavity R901096083
Flow Control Valves DRFN - 10A 04.05.01.00.85.30.000 flow divider and combiner, common cavity R901096086
04.05.01.00.85.40.000 flow divider and combiner, common cavity R901096087
ST - C - 06 OD.21.01.03.56.00.000 cartridge restrictor, common cavity R901109366 X
OD.21.01.03.36.00.000 cartridge restrictor, common cavity R901109830 X
ST - C - 10A
OD.21.01.04.36.00.000 cartridge restrictor, common cavity R901109831 X
ST - C - 12A OD.21.01.03.89.00.000 cartridge restrictor, common cavity R901109832 X
ST - C - 16A OD.21.01.03.75.00.000 cartridge restrictor, common cavity R901109837 X
VLST-10A 04.84.01.03.85.00.000 Logic Element, adjustable, 2-8 bar, common cavity R901104079
VLST-16A 04.84.01.03.27.00.000 Logic Element, adjustable, 4-12 bar, common cavity R901109372
VLST-20A 04.84.01.00.58.11.000 Logic Element, fixed setting, 11,5 bar, common cavity R901109867
Logic Elements
VLSP-10A 04.84.03.03.85.00.000 Logic Element, adjustable, 2-8 bar, common cavity R901109375
VLSP-16A 04.84.03.03.27.00.000 Logic Element, adjustable, 4-12 bar, common cavity R901109871
VCSQ - 16A 04.84.06.00.27.06.000 logic element, pressure compensator, combination type, common cavity R901162013
VDSD - 10A 04.77.22.00.85.05.000 directional spool type, direct actig external pilot, external vented, common cavity R901109495
directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
OD.71.01.51.01.00.000 X
style, special cavity R979015064
Directional Valves,
Mechanically Operated. directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
VDP-32 OD.71.01.51.02.00.000 X
style, special cavity R979015065
directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
OD.71.01.51.04.00.000 X
style, special cavity R979015066
VFC 05.99.05.00.09.00.00A shuttle 05990500090000A X
Shuttle Valves
SELB - 08A 04.94.05.00.56.00.000 shuttle, common cavity R901161981 X
OD.13.10.51.30.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126871 X
VED-8I-32-06-SE
OD.13.10.51.40.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126872 X
VED-8I-32-06-SI OD.13.11.51.30.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126873
VED-8I-32-06-NC OD.13.20.51.30.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126892
VED-8I-42-06-CA OD.14.40.58.30.00.000 solenoid operated valves, spool 4-way 2-position, common cavity R901113693
VED-8I-43-06-ABT OD.14.32.58.44.00.000 solenoid operated valves, spool 4-way 3-position, common cavity R901113705
VEI - 8A - 2A - 06 -
OD.15.06.18.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901091130 X
NA - S - NSS
VEI - 8A - 2A - 06 -
OD.15.05.18.3A.S8.000 2/2 poppet directional valve, normally closed, extra spring, both way, common cavity R934003080
NC - S - X - NSS
VEI - 8A - 2A - 09 -
OD.15.06.17.1A.S0.000 2/2 poppet directional valve, normally open, both way, special cavity R901113677
NA - S - NSS
VEI - 8A - 2A - 09 -
OD.15.05.17.3A.S8.000 2/2 poppet directional valve, normally closed extra spring, both way, special cavity R901119220
NC - S - X - NSS
VEI - 8A - 2A - 10A -
OD.15.06.36.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901080489
NA - S - NSS
VEI - 8A - 2A - 10A -
OD.15.05.36.3A.S0.000 2/2 poppet directional valve, normally closed, both way, common cavity R901090947 X
Solenoid Valves NC - S - NSS
VEI - 8A - 2A - 10A -
OD.15.05.36.3A.S8.000 solenoid operate valves, poppet 2 way normally closed, extra spring, common cavity R901090945 X
NC - S - X - NSS
VEI - 8A - 2A - 12 -
OD.15.06.21.1A.S0.000 2/2 poppet directional valve, normally open, extra spring, both way, special cavity R901104409
NA - S - NSS
VEI - 8A - 2A - 12 -
OD.15.05.21.3A.S8.000 2/2 poppet directional valve, normally closed, extra spring, both way, special cavity R901119221
NC - S - X - NSS
VEI - 8A - 2A - 12A - OD.15.06.89.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901091139
NA - S - NSS OD.15.06.89.1A.S0.001 2/2 poppet directional valve, normally open, both way, common cavity R901091140
VEI - 8A - 2T - 06 -
OD.15.32.18.1A.S0.000 2/2 poppet directional valve, normally open, double lock, both way, common cavity R901091171
NA - S - NSS
VEI - 8A - 2T - 06 -
OD.15.31.18.3A.S0.000 2/2 poppet directional valve, normally closed, double lock, both way, common cavity R901082015 X
NC - S - NSS
VEI-8I-2A-06-NC-S-
OD.15.05.18.3I.S0.000 solenoid operated valves, poppet 2-way normally closed, common cavity R901090953
NSS
VEI - 8I - 2A - 06 - NC
OD.15.01.18.3I.S0.000 2/2 poppet directional valve, normally closed, one way, common cavity R901090962 X
- S1 - NSS
VEI-8I-2A-06-NC-S1-
OD.15.01.18.3M.S0.000 solenoid operated valves, poppet 2-way normally closed, common cavity X
NSS, N9 R901090966
OD.02.17.01.30.OC.000 coil, 24VDC, Hirschmann R901083065 X
OD.02.17.01.30.OB.000 coil, 12VDC, Hirschmann R901090821 X
S8 - 356
OD.02.17.01.30.OW.000 coil, 110 V RAC R901087981 X
Coils
OD.02.17.01.30.OZ.000 coil, 220 V RAC, Hirschmann R901085466 X
OD.02.17.20.30.OC.000 coil, 24VDC, Deutsch connector R901094611 X
S8 - 356 2
OD.02.17.20.30.OB.000 coil, 12VDC, Deutsch connector R901094609 X
Manifolds Manifold OC.10.09.00.40.00.000 manifold 2 way aluminum R901082022

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Cartridge Valves - RC X BROC
BR RC Brazil BR Oil Control Cavity Interchange? Note
Group 01

BRBR Code Directional SAP Code Description BROC Code


R901090962 OD.15.01.18.3I.S0.000 VEI-8A-2A-06-NC-S1-NSS No simple restraint A to B - 30 L/min
44002803 RCSS2SE8K10M
R901090966 OD.15.01.18.3M.S0.000 VEI-8I-2A-06-NC-S1-NSS, N9 No simple restraint A to B - 30 L/min + Manual Ove
Group 02
BRBR Code Directional SAP Code Description BROC Code
44005503 RCEE4WE8K10M --- --- --- Valve without consumption

44005803 RCEX2WH8GA10M --- --- --- Valve without consumption

44005703 RCEX2WH8K10M --- --- --- Valve+housing without consumption

44002603 RCSC2SE8K10M --- --- --- Valve without consumption


Group 03
BRBR Code Flow SAP Code Description BROC Code
43048503 RC2FP10KI10M*-SO417565 --- --- --- Valve without consumption
43048103 RC2FP10KI10MA --- --- --- Valve without consumption
43048403 RC2FP10KI10MB --- --- --- Valve without consumption
43052503 RC2FP10KI10MC R901106675 04.04.02.04.85.40.000 VRFD-10 Yes Totally adjustable (0 - 30 Lpm)
43105303 RC3MK10KE10M R901109368 04.01.02.03.56.00.000 STVU-08A No
43105503 RC3MK10KM10M R901109839 04.01.02.04.56.00.000 STVU-08A No
44005403 RCEB2WE8K10M --- --- --- Valve without consumption
Group 04
BRBR Code Flow - Sequence SAP Code Description BROC Code
43219503 RC1DZ10KE10AM --- --- --- Valve without consumption
43219603 RC1DZ10KE10BM --- --- --- Valve without consumption
43219803 RC1DZ10KE10CM R901106472 04.13.05.03.85.10.000 VSPY-10A Yes
43218703 RC1DZ10KE10DM R901106472 04.13.05.03.85.10.000 VSPY-10A Yes
43017603 RC1F8KM10M R901109366 OD.21.01.03.56.000 STC-06 Yes
Group 05
BRBR Code Flow SAP Code Description BROC Code
43018503 RC2FC8KI10AM R901095981 04.02.02.04.85.40.000 VRFB-10A Yes
43162903 RC2FC8KI10BM --- --- --- Valve without consumption
43163403 RC2FC8KI10CM R901095981 04.02.02.04.85.40.000 VRFB-10A Yes
Group 06
BRBR Code Pressure SAP Code Description BROC Code
43218603 RC1DR10KI10*M-SO41-7564 --- --- --- Valve without consumption
43204603 RC1DR10KI10AM --- --- --- Valve without consumption
43204703 RC1DR10KI10BM R901109742 04.95.04.03.85.08.000 VRPR-10A Yes
43204803 RC1DR10KI10CM --- --- --- Valve without consumption
43018003 RC1DR10KI10DM --- --- --- Valve without consumption
Group 07
BRBR Code Isolator - Check SAP Code Description BROC Code
43219003 RC1SV8K10AM R901106627 04.33.06.00.56.00.00A VSON-08A Yes
43219703 RC1SV8K10BM --- --- --- Valve without consumption
43210003 RC1SV10K10AM R901106629 04.33.05.00.85.00.00A VSON-10A No
43210103 RC1SV10K10BM --- --- --- Valve without consumption
BR RC Brazil BR Oil Control Cavity Interchange? Note
Group 08
BRBR Code Directional SAP Code Description BROC Code
F000530013 RCEC3WE8GA10M/24V --- --- --- Valve without consumption
R901126871 OD.13.10.51.30.00 VED-8I-32-06-SE Yes
44005303 RCEC3WE8K10M
R901126872 OD.13.10.51.40.00 VED-8I-32-06-SE Yes
44005603 RCEC3WH8K10M --- --- --- Valve without consumption
44005903 RCEC3WH8KI20AM --- --- --- Valve without consumption
R979015064 OD.71.01.51.01 VDP-32 Yes Switching pressure 03 - 25 Bar
44006003 RCEC3WH8KI20BM R979015065 OD.71.01.51.02 VDP-32 Yes Switching pressure 20 - 60 Bar
R979015066 OD.71.01.51.04 VDP-32 Yes Switching pressure 70 - 100 Bar
Group 09
BRBR Code Directional SAP Code Description BROC Code
43105403 RC1AT8K10M VAL. ALTERNADO R901161981 04.94.05.00.56.00.000 SELB-08A Yes
Group 10
BRBR Code Pressure SAP Code Description BROC Code
43167203 RC1DB10KE10AM 70BAR --- --- --- Valve without consumption
43167303 RC1DB10KE10BM --- --- --- Valve without consumption
43167403 RC1DB10KE10CM --- --- --- Valve without consumption
43217503 RC1DB10KI10AM 70BAR --- --- --- Valve without consumption
43217603 RC1DB10KI10BM 140BAR --- --- --- Valve without consumption
43222203 RC1DB10KI10BV 140BAR --- --- --- Valve without consumption
R901113622 04.11.56.03.85.10.000 VSBG-10A Yes Pressure range 35 - 140 Bar
43214403 RC1DB10KI10CM 250BAR R901113624 04.11.56.03.85.20.000 VSBG-10A Yes Pressure range 105 - 210 Bar
R901113626 04.11.56.03.85.35.000 VSBG-10A Yes Pressure range 175 - 350 Bar
Group 11
BRBR Code Pressure SAP Code Description BROC Code
43018103 RC1DB8KI10AM 70BAR R901113622 04.11.56.03.85.10.000 VSBG-10A No Pressure range 35 - 140 Bar
43217203 RC1DB8KI10BM 140BAR R901113624 04.11.56.03.85.20.000 VSBG-10A No Pressure range 105 - 210 Bar
43017103 RC1DB8KI10CM 250BAR R901113626 04.11.56.03.85.35.000 VSBG-10A No Pressure range 175 - 350 Bar
Group 12
BRBR Code Isolator - Check SAP Code Description BROC Code
43217903 RC1S10K10AM RET. 0.35BAR R901106596 04.31.23.00.85.00 VUCN-10A Yes Cracking pressure 0,5 Bar
43214503 RC1S10K10BM RET. 1,0BAR R901106596 04.31.23.00.85.00 VUCN-10A Yes Cracking pressure 0,5 Bar
43223303 RC1S10K10AV RET. 0.35BAR --- --- --- Valve without consumption
43218003 RC1S10K10CM RET. 4.5BAR R901106601 04.31.23.00.85.05 VUCN-10A Yes Cracking pressure 5 Bar
Group 13
BRBR Code Isolator - Check SAP Code Description BROC Code
43041103 RC1S8K10AM RET. 0,35BAR R901007308 04.31.20.00.56-00 VUCN-08A Yes Cracking pressure 1 Bar
43217703 RC1S8K10BM RET. 1BAR R901007308 04.31.20.00.56-00 VUCN-08A Yes Cracking pressure 1 Bar
43217803 RC1S8K10CM RET. 4.5BAR R901106550 04.31.20.00.56-05 VUCN-08A Yes Cracking pressure 5 Bar
Group 14
BRBR Code Pressure SAP Code Description BROC Code
43167503 RC3DB10KE10AM --- --- --- Valve without consumption
43167803 RC3DB10KE10AM SO41-7946 R901113609 04.11.55.03.85.10 VSBN-10A Yes
43167603 RC3DB10KE10BM Valve without consumption
R901113609 04.11.55.03.85.10 VSBN-10A Yes
43167703 RC3DB10KE10CM R901113610 04.11.55.03.85.20 VSBN-10A Yes
R901115702 04.11.55.03.85.35 VSBN-10A Yes
43217303 RC3DB10KI10AM 70 BAR --- --- --- Valve without consumption
43217403 RC3DB10KI10BM 140 BAR --- --- --- Valve without consumption
R901113609 04.11.55.03.85.10 VSBN-10A Yes
43214703 RC3DB10KI10CM R901113610 04.11.55.03.85.20 VSBN-10A Yes
R901115702 04.11.55.03.85.35 VSBN-10A Yes
BR RC Brazil BR Oil Control Cavity Interchange? Note
Group 15
BRBR Code Pressure SAP Code Description BROC Code
43018203 RC3DB8KI10AM 70BAR --- --- --- Valve without consumption
R901113599 04.11.49.03.56.10 VSBN-08A Yes
43217103 RC3DB8KI10BM 140BAR
R901097728 04.11.49.03.56.20 VSBN-08A Yes
R901113599 04.11.49.03.56.10 VSBN-08A Yes
43017003 RC3DB8KI10CM 250BAR R901097728 04.11.49.03.56.20 VSBN-08A Yes
R901091914 04.11.49.03.56.35 VSBN-08A Yes

Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]

You might also like