Catalogo Valvulas Cartucho Oil Control
Catalogo Valvulas Cartucho Oil Control
Catalogo Valvulas Cartucho Oil Control
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
INDEX
General Information 03
Mechanical Data 23
Solenoid Data 26
Special Valves 42
Check Valves 44
Counterbalance Valves 45
Logic Elements 69
Shuttle Valves 78
Solenoid Valves 80
Coils 101
Manifolds 103
Cavities 116
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Hydraulic valves RE 64 020-B1/08.05
General Information
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
What you need to know about these Operating Instructions
These Operating Instructions apply to Rexroth hydraulic valves for mobile applications and consist of the following
three parts.
If you do not have all three parts, please request the missing part from Bosch Rexroth AG.
Only if all the information contained in all parts of the three-part Operating Instructions is observed
can safe operation of the Rexroth hydraulic valve be ensured.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Contents
1 General 4
1.1 Scope of application of these Operating Instructions 4
1.2 To assist your understanding of these Operating Instructions 4
1.3 Further important and applicable documents 4
2 Responsibilities 5
2.1 Liability and warranty 5
2.2 Responsibilities of the operator/user 5
4 Pressure fluids 11
4.1 General information on pressure fluids 11
4.2 Malfunctions due to contamination of pressure fluid 11
4.3 Topping up / refilling 12
7 Maintenance 18
7.1 Definitions of terms 18
7.2 Safety during maintenance tasks 19
7.3 Inspection and servicing 20
7.4 Repair 20
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
1 General
1.1 Scope of application of these Operating Instructions
These Operating Instructions apply to Rexroth control and regulating valves for mobile
control systems.
These Operating Instructions are intended for the use of the system manufacturer and the
designer as well as the operator.
The designer can be a person that is responsible for the design of a hydraulic system in
which Rexroth valves are used.
DANGER This symbol of danger indicates high risk, danger of loss of life or of serious injury.
WARNING This symbol of danger indicates medium risk, injury and serious damage to property.
CAUTION This symbol of danger indicates slight risk and possible damage.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
2 Responsibilities
2.1 Liability and warranty
Bosch Rexroth AG is not liable for damages that result from non-compliance with or
disregard of this user’s manual.
Any modification of the Rexroth valves beyond the extent described in these Operating
Instructions shall render the warranty and, if applicable, any further concessions granted,
null and void.
Bosch Rexroth AG shall only be liable if the scope of delivery was shown to be defective.
Bosch Rexroth AG shall not be liable if a deficiency occurs that involves parts having been
replaced by the customer with equivalent but not identical parts as specified by the
manufacturer.
WARNING Mineral-oil-based pressure fluid is hazardous to health and water; it may also be
flammable.
It may only be used if the relevant safety datasheet from the manufacturer is
available and all the measures stipulated therein have been implemented.
Important The Operating Instructions supplied by Bosch Rexroth AG – in all its parts and with all
other relevant applicable documents – contain safety-related information that must be
included by the system manufacturer/user in the Operating Instructions to be written for the
final product.
A wide range of dangers can arise from the combined actions of the Rexroth valve and the
machine or system in which the valve is installed.
System manufacturers, users or operators must therefore ensure that the Rexroth valve is
only installed if it is suitable, without restrictions, for the proposed application at the
installation location.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3 Important basic safety instructions
3.1 Proper use
Rexroth valves have been designed and constructed for the control and regulation of energy
and signals using a flow of oil. The safety components integrated into the Rexroth valves
satisfy at least Safety Category 1 in accordance with EN 954-1.
However, only by carefully observing these Operating Instructions can accidents be pre-
vented and problem-free operation of your Rexroth valve be guaranteed.
Use the Rexroth valve only as described in these Operating Instructions and if it is stored,
installed, operated and maintained in accordance with the technical data, operating and
ambient conditions as defined in these Operating Instructions. The limiting values given in
Part III, Technical Datasheet must be observed.
Information on storage and longer standstills is given in 5 Storage and longer standstills.
Rexroth valves may only be operated if they are in perfect technical condition.
The Rexroth valve must be operated only with the pressure fluids intended for the purpose
specified in Part III, Technical Datasheet . Information on using the Rexroth valve with
different pressure fluids is available on request.
The Rexroth valve must be used only for the purpose specified in Part III, Technical
Datasheet. The connections, operating conditions and performance data defined in these
Operating Instructions must not be changed.
Important If you wish to use the Rexroth valve with connections, operating conditions and
performance data or for purposes other than those defined by Bosch Rexroth AG in these
Operating Instructions, you should contact Bosch Rexroth AG in advance. The Rexroth
valve must not be used with connections, operating conditions and performance data or for
purposes other than those defined in these Operating Instructions without the written
agreement of Bosch Rexroth AG.
Rexroth valves may only be converted within the scope given in Part II, Product-specific
Instructions.
During setting up or maintenance work, unless impractical, the safety devices fitted by
Bosch Rexroth AG must be present, properly installed and in full working order. They
must not be relocated, bypassed or rendered ineffective.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3.2 Improper use
Modifications and/or conversions of a Rexroth valve are only permissible within the scope
given in Part II, Product-specific Instructions.
Tamperproof lead seals installed by Bosch Rexroth AG shall not be removed or damaged
except when this is necessary in the course of maintenance tasks defined in the Operating
Instructions.
Rexroth valves for which these Operating Instructions apply shall not be used in potentially
explosive atmospheres. Special Rexroth valves are available that can be used in potentially
explosive atmospheres.
Pressure control valves without a type examination in accordance with the EU Pressure
Equipment Directive must not be used as safety valves in safety-related applications.
The nameplate must not be removed or painted over.
Specialist personnel are those who, using their specialist training, knowledge and experience
as well as familiarity with the relevant conditions, can recognise possible dangers and under-
take the necessary measures to eliminate possible accidents.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
For maintenance of the hydraulic components, the personnel must fulfil the following
requirements:
− They have been instructed in the relevant activity.
− Specialist knowledge of hydraulics is required.
For maintenance of the Rexroth valves, the personnel must fulfil the following requirements:
− The personnel must be hydraulics experts instructed in the tasks as defined above.
− The personnel must be familiar with the function of the hydraulic system as a whole, from
subsystems to their interaction with the function of the machine as a whole.
− The personnel must be able to read hydraulic circuit diagrams, interpret individual func-
tions from their symbols and understand function diagrams.
− The personnel must possess knowledge of the function and construction of hydraulic
elements in general and of the Rexroth valves to be maintained in particular.
See also 7.4 Repair.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
3.4 Ancillary dangers and protective measures
DANGER
Connections and Risk of injury or loss of life from Depressurise the hydraulic system before starting
pressure lines (pipes sprayed pressure fluid under high maintenance work. Relieve any accumulators of
and hoses) pressure during maintenance work. pressure.
Rectify leaks immediately.
There is a health hazard if escaping Tanks installed above the valve being repaired must
pressure fluid comes into contact be emptied before work is started.
with the skin. This is a particular
risk if the tank is at a higher level
during repair work
Surfaces of comp- Risk of burning due to high surface Allow hydraulic parts to cool before commencing
onents and pressure temperatures maintenance work.
lines
Wear protective clothing.
Failure caused by excessive Shield the valve from the direct effect of high-
moisture entry following cleaning pressure water jets.
with a high-pressure cleaner
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CAUTION Risk of environmental pollution
3.5 Disposal
Completely empty valve and dispose as scrap metal.
Important To completely empty means that the valve must be properly emptied so that no more
pressure fluid can drip out.
The valve does not need to be cleaned when it is completely empty.
Collect residual pressure fluid and dispose of it in accordance with the instructions given in
the safety datasheet of the pressure fluid.
Dispose of electronic products in accordance with the applicable regulations.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
4 Pressure fluids
4.1 General information on pressure fluids
The effectiveness of pressure fluid diminishes as it ages (undergoes chemical changes).
Acids and resinous residues form that may cause moving parts inside the valves to stick.
The following factors accelerate the ageing process:
− high temperatures
− oxygen in the pressure fluid
− air humidity
− water
− metallic catalysts
− high operating pressure
− contaminants.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
4.3 Topping up / refilling
When topping up / refilling your hydraulic system, make sure that you use pressure fluid of
the same sort and type and from the same manufacturer.
If the fluid is heavily contaminated or prematurely aged, then the system, including the tank
must be cleaned and flushed before refilling. New pressure fluid must always be filtered in
accordance with the required cleanliness class, as it does not normally meet the required
cleanliness class in the as-supplied state. Flush out lines and hoses before installation.
Use a filter unit to fill the pressure fluid tank. Ensure that the filter element is clean. Do not
remove the filter strainers from filler necks or the filter element from filters before filling the
pressure fluid tank.
Important The fineness of the filter shall correspond to the cleanliness class required by the overall
system and if possible be even finer. The filter unit used shall fulfil the requirements for
functional safety and service life.
If possible, fill the pressure fluid tank via a filling coupling, if possible using a filter in the
return line.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
5 Storage and longer standstills
5.1 Storage conditions
Store the Rexroth valve only in a dry, dust-free atmosphere that is free of corrosive agents
and vapours, has a low moisture content and no large variations in temperature.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
6 Assembly and bringing into first use
CAUTION Risk of injury and damage
Wear safety gloves to avoid being injured by sharp edges.
Assembling and bringing into (first) use shall only be done by an instructed,
authorised hydraulics expert who has the required specialist knowledge.
6. Ensure that the interfaces of the system/machine and the installation conditions provide
for safe operation of the Rexroth valve. If in doubt, consult the people responsible for the
overall system / functional machine.
7. Based on the operating instructions for the system or machine in which the Rexroth valve
is to be installed, check whether bringing the hydraulic system into use could lead to
uncontrolled, dangerous movements. Where appropriate, take into account the hazard
analysis / risk assessment for the system or machine.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
8. Take the precautions appropriate to the anticipated dangers, e. g.:
¾Ensure that the cylinder piston rod can move out without danger.
¾Use a hoist or other lifting device to additionally secure lifted loads.
9. As part of bringing into (first) use, check whether the electric motors and valve solenoids
can be switched manually using the electrical controls of the system/machine. If they
cannot be switched manually or they can but with difficulty you must provide a remote
control (e. g. test boxes for Rexroth proportional valves) for the internal function test of
the hydraulic system.
10. Draw up a sequential program for bringing into (first) use and store it with the technical
documentation as an appendix to the Operating Instructions.
11. Divide the functional circuit diagram into separate mini-circuits that can each be started
up in succession.
12. Read the functional circuit diagram and seek clarification of any unclear text or diagrams.
More information on the functioning of subassemblies is given in the Technical
Datasheet.
13. Establish into which position valves are to be switched, or how valves are to be set.
14. Put up any necessary directional, prohibitive or informative signs and check whether the
meaning of these signs is explained in the Operating Instructions.
15. Follow this sequence for bringing into (first) use
− Pump circuit
− Parts of the control system: e. g. pressure cut-off and switchover, open centre,
pressure reduction, etc.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
6.2 Bringing into first use, subsequent bringing into use
¾Take suitable precautions when bringing into first use to maintain the required purity of
the pressure fluid.
− Make sure that the quality of the pressure fluid is not diminished by contaminants in
the system.
− Completely remove any oil residues left over from the factory test.
− Remove any gummed oil which may have formed due to incorrect storage.
¾Connect all connection lines in accordance with the installation instructions provided by
the manufacturer of the connectors.
¾Set the pressure and flow control valves, pump regulator, signalling elements such as
pressure switches, limit switches and temperature regulators to the settings and values
defined in the sequential program (see 6.1 Before bringing into first use).
¾Do not remove the lead seals. Damaged or removed lead seals indicate improper use of
the hydraulic product.
¾Bleed the hydraulics (valve, pump, motor, line, cylinder). Bleed the hydraulics lines to
consumers or measuring points at the highest point, if possible. Before bringing into use,
the valve must be filled with pressure fluid and the system in which the valve is installed
must be completely bled.
Important Details on bleeding can be found in the Operating Instructions of the respective system.
Important Details on fine-tuning can be found in the Operating Instructions of the respective system.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
¾Check the operating temperature after the machine has been running continuously for
several hours. Too high an operating temperature indicates that there are faults that need
to be analysed and rectified.
¾After bringing the machine into first use, have a sample of the pressure fluid analysed to
ensure that it achieves the required cleanliness class. Change the pressure fluid if the
required cleanliness class is not achieved. If the pressure fluid is not tested in the lab-
oratory after bringing the machine into first use: Change the pressure fluid.
Important Information on how to perform the function test and pressure test can be found in the
Operating Instructions of the respective system.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7 Maintenance
7.1 Definitions of terms
The term "Maintenance" as defined in DIN 31051 encompasses all measures to maintain
and restore the desired conditions and to determine and assess the actual condition of the
technical devices of a system.
These measures are divided into the following categories:
− Inspection (determining the actual condition)
− Servicing (maintaining the desired condition)
− Repair (restoring the desired condition).
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7.2 Safety during maintenance tasks
DANGER Dangers due to reduced safety during repair work
Experience has shown that the number of accidents is higher during repair work than
during normal operations. Therefore, in the interests of safety, please observe all the
following safety instructions at all times.
¾Regularly check any safety devices – if installed – for their correct functioning.
¾Perform all maintenance work properly, completely and within the stipulated
periods and make a record of the work.
¾Cordon off the maintenance zone at a sufficient distance before commencing
work.
¾Pay attention to cleanliness to avoid malfunctions caused by contamination.
¾Exercise extreme vigilance when operating the hydraulic product in maintenance
mode, which may in certain circumstances necessitate the temporary removal of
certain safety devices. Switch off the hydraulic system and secure it against being
unintentionally switched on again.
¾The set values of safety valves shall not be altered by the user. Any readjustment
shall be performed by authorised testing bodies only.
¾Wear safety goggles, safety gloves and safety shoes. Depressurise the hydraulic
product, relieve the pressure in any pressure accumulators.
¾Allow pressure lines and sections of the system which have to be opened to cool
down before commencing maintenance work.
¾Open with care any segments that have to remain under pressure.
¾Note that if check valves are located in the pressure lines above the pumps, the
hydraulic system may still be under pressure even after it has been disconnected
from the actual pressure supply. Advance all cylinders to their safe end position.
¾Lower all loads. Use an external support if it is not possible to lower a load. Never
perform any maintenance work on raised units without external support.
¾Switch off all pumps.
¾Mechanically support vertical cylinders so that they cannot descend.
¾Only new, interchangeable and tested components, replacement parts and
lubricants in original-equipment quality are approved for use/replacement.
¾For reasons of safety, the installation of untested components is strictly
prohibited.
¾Make sure that all safety devices are properly installed and have undergone a
function test before bringing the system (back) into use.
¾Remove all tools and materials needed for maintenance from the hydraulic
product after the work has been completed.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
7.3 Inspection and servicing
The objective of inspection and servicing is
− to maintain all system functions along with the initial parameters of the system
− to ensure continual availability of the system
− to detect weak points
− to ensure that the system attains the required service life.
We strongly recommend the use of an inspection and servicing book, in which all work
specific to the system and the site, and all inspection and servicing intervals should be
defined and documented.
Important The product-specific inspection and servicing plan for the Rexroth valve can be found in
Part II, Product-specific Operating Instructions.
7.4 Repair
All repairs of Rexroth valves must be carried out only by workshops authorised by
Bosch Rexroth AG.
Bosch Rexroth AG © This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Robert-Bosch-Straße 2 reproduced or given to third parties without its consent.
71701 Schwieberdingen, Germany
The data specified above only serve to describe the product. No statements
Fax +49 (0) 7 11 / 811-1798
concerning a certain condition or suitability for a certain application can be
[email protected]
derived from our information. The given information does not release the user
www.boschrexroth.de
from the obligation of own judgement and verification. It must be remem-
bered that our products are subject to a natural process of wear and aging.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
HYDRAULIC FLUID
General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic
systems such as, for example:
- MINERAL OIL BASED HYDRAULIC FLUIDS HL
(DIN 51524 part 1)
- MINERAL OIL BASED HYDRAULIC FLUIDS HLP
(DIN 51524 part 2).
For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult BROC.
Viscosity class: according to ISO-DIN, it is expressed by the ISO-VG number which indicates the average
NLQHPDWLFYLVFRVLW\DW&)±PP2VRUFHQWLVWRNHV±F6W
Test conditions: the main performance curves and specifications shown in this catalogue are obtained using
mineral based fluid ISO VG 46, with a cleanliness class of 17/14 - 18/14 ISO 4406 (8-9 NAS 1638), at a
temperature of 30/40°C (86/104°F). More detailed technical characteristics are available at BROC.
Fluid temperature range: the valves are designed for fluids at a temperature between -30°C and +100°C (-22°F
and +212°F). For temperatures outside this range, consult BROC.
Internal leakage: most BROC valves have a leak proof seat design, but there are different families of valves
each providing a different level of sealing depending on the type and number of the poppets; the leakage features
of each valve type must be selected in order to suit the application.
The table A (pg. A-PD3) shows the AVERAGE LEAKAGE for various valve families; the readings are achieved in
the specified test conditions, and are measured in cm3/min or drops/min.
The ratio between them is:
1 cm3/min (0.06 in3/min) = 15y20 drops/min.
For pressure relief valves the leakage is indicated at re-seating conditions, identified as X% of pressure relief
setting.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA
TECHNICAL DATA
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
PRESSURE SETTING: BROC valves are supplied pre-set at the standard pressure setting shown by the
relevant catalog sheet. Whenever the application requires a re-adjustment, please ensure that the limits of the
indicated pressure range are never exceeded.
SEALING OF VALVE ADJUSTERS: plastic sealing caps are available for most cartridge valves.
The cartridges can be purchased Factory sealed.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
CONTINUOUS DUTY COILSCONTINUOUS
- ED 100% DUTY COILS - ED 100%
ED = ( ti / tc ) Ã 100 %
HEAT INSULATION DIN VDE 0580
ALL COILS ARE RATED FOR ED = 100 % All COILS
PROVIDED THAT TEMPERATURE LIMIT OF THEIR
INSULATION CLASS IS NOT EXCEEDED. COMPLETE COIL CLASS H 365qF (180qC)
Copper wire 392qF (200qC)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA
TECHNICAL DATA
STANDARD MANUAL OVERRIDE
STANDARD MANUAL OVERRIDE OPTIONS
OPTIONS
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
SPECIAL MANUAL OVERRIDE OPTIONS
SPECIAL MANUAL OVERRIDE OPTIONS
PULL STYLE
CABLE HAND AVAILABLE ON FOLLOWING MODELS:
OPERATED OPERATED x 2 way 2 position pilot operated normally closed series 8A size 06
OPERATION
To operate manual override, pull and hold the knob. This override is not detented.
Force required to operate is approximately 11.2 lbs (50 N).
This override can also be remote operated by a cable fixed to the M8 thread. In this
case the spring may not provide enough force to overcome internal cable friction and
the user must provide an external means of returning the cable.
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL
TECHNICAL DATA
DATA
HYDRAULIC FLUID
SEALS
O - RINGS
ORDERING CODE:
Acryl - Nitrile Butadiene Rubber NBR ( BUNA-N ) standard for
temperatures between -22°F (-30°C) and +212°F (+100°C). CARTRIDGE VALVES Substitute OD with KD
FLUOROCARBON FPM ( Viton ) and other compounds are VALVES IN STANDARD MANIFOLD Same as cartridge KIT
available on request. VALVES IN EMERGENCY MANIFOLD Substitute OE with KE
Rev.06.05 7.01.040.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL DATA TECHNICAL DATA
CARTRIDGE INSTALLATION
It is recommended to follow these steps: x Inspect cavity for burrs or other machining irregularities
x Inspect the cartridge to ensure that no external which could damage seals during installation.
contaminant is present. x Dip the cartridge in clean oil.
x Check that O-ring and back-up rings are intact and x Screw the cartridge in BY HAND until the O-ring is met,
correctly positioned. The O-ring should be towards the then tighten to the torque specified in the cartridge
higher pressure port if only one back-up ring is present catalogue page. Do not exceed maximum torque:
or between double back-up rings if both ports receive overtightening may cause valve failure.
high pressure.
IMPORTANT: Continuous high frequency vibrations especially if combined with pulsating pressure, may cause cartridge
unscrewing and consequent O-ring extrusion. Please consult our Technical Department.
COIL INSTALLATION
COIL WITH O-RING SEATS (S7 - S5) COIL WITHOUT O-RING SEATS (S8-356)
It is recommended to follow these steps: It is recommended to follow these steps:
x Insert 1st O-Ring (see drawing) x Insert 1st O-Ring (see drawing)
x Insert coil x Insert coil
x Insert 2nd O-Ring (see drawing) x Tighten BY HAND coil retaining nut to the torque
x Tighten BY HAND coil retaining nut to the torque specified in the cartridge catalogue page. The 2nd O-
specified in the cartridge catalogue page. Ring is fixed inside the nut.
Example: Example:
Nut
Nut
2nd O-Ring
2nd O-Ring
Coil
Coil
1st O-Ring
1st O-Ring
IMPORTANT: O-rings are the only protection against water infiltration between tube and coil, which may lead in short time to
coil failure. The proper mounting of both O-rings is therefore necessary to ensure normal life of coils when operating in presence
of water, ice, moisture etc. Oil Control cannot guarantee any IP protection degree if both O-rings are not properly mounted on
coils.
Rev.06.05 7.01.045.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
TECHNICAL
TECHNICAL DATA
DATA
CONTAMINATION
CONTAMINATION -- FILTRATION
FILTRATION
ABSOLUTE
NOMINAL FILTRATION CONTAMINATION
TYPE OF VALVE FILTRATION RATING ACCORDING TO
ISO 4572
Systems/components operating at
HIGH PRESSURE > 3600 psi (250 bar)
Systems/components operating at
MEDIUM PRESSURE up to 3600 psi 15 X = 12…15 20 / 18 / 15 9
(250 bar)
Systems/components operating at
LOW PRESSURE < 1450 psi (100 bar)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Pressure Control Valves
VSBN-08A
VSPY-10A
VSBN-10A
VSPY-10A
VSBG-10A
VSPY-10A
VSNG-10A
VRPP-10A
VSPN-10A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY
VSBN-08A SIZE 08
VSBN-08A 04.11.49 - XSIZE
- 56 08
-Z 04.11.49 - X - 56 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
145-1000 375 725
05 (10-70) (26) (50)
500-2000 725 1450 X = 03 11.04.23.002
10 (35-140) (50) (100)
X = 03 1500-3000 1145 2900
20 (105-210) (79) (200)
Tamper resistant cap
35
2500-5000 2465 5000 X = 73 11.04.23.004
(175-350) (170) (350)
500-5000 1044 2900
X = 04 35 (35-350) (72) (200) Special settings available. Contact factory authorized
500-5000 1044 2900 representative for ordering code.
X = 73 35 (35-350) (72) (200)
Rev.0605 Page. AA1.020
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY
VSBN-10A SIZE 10
VSBN-10A 04.11.55 - XSIZE
- 85 10
-Z 04.11.55 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, DIRECT ACTING GUIDED
RELIEF,POPPET
DIRECTTYPE
ACTING GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY
VSBG-10A SIZE 10
VSBG-10A 04.11.56 - XSIZE
- 85 10
-Z 04.11.56 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, BI-DIRECTIONAL RELIEF, BI-DIRECTIONAL
DIRECT ACTING POPPET TYPE DIFFERENTIAL
DIRECT AREATYPE DIFFERENTIAL AREA
ACTING POPPET
COMMON CAVITY COMMON CAVITY
VSNG-10A SIZE 10
VSNG-10A 04.11.59 - XSIZE
- 85 10
-Z 04.11.59 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar)
(bar) (bar/turn) (Q=5 l/min)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, PILOT
RELIEF, PILOT OPERATED
OPERATED SPOOL
SPOOL TYPE
TYPE
COMMON CAVITY
COMMON CAVITY
VSPN-10A
VSPN-10A SIZE 10 04.12.08
04.12.08 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
X = 03 2000-6000 2030 5000 11.04.23.002
35 (140-420) (140) (350) Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
RELIEF, PILOT OPERATED RELIEF,
SPOOL TYPE
PILOT OPERATED SPOOL TYPE
EXTERNAL DRAIN EXTERNAL DRAIN
COMMON CAVITY COMMON CAVITY
VSPY-10A SIZE 10
VSPY-10A 04.13.05 - XSIZE
- 8510
-Z 04.13.05 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
2000-6000 2030 5000 11.04.23.002
35 (140-420) (140) (350) Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING,
PRESSURE REDUCING, PILOT
PILOT OPERATED
OPERATED SPOOL
SPOOL TYPE
TYPE
COMMON CAVITY
COMMON CAVITY
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi Ordering code Description
(bar) (bar/turn) (bar)
145-2000 696 1450
10 (10-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
11.04.23.002
Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING
PRESSURE REDUCING AND
AND RELIEVING,
RELIEVING,
PILOT OPERATED SPOOL TYPE
PILOT OPERATED SPOOL TYPE
COMMON CAVITY
COMMON CAVITY
VRPX-10A SIZE 10 04.93.07
04.93.07 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (reduc. mode)
500-2000 696 1450
10 (35-140) (48) (100)
1000-4000 1276 2900
20 (70-280) (88) (200)
11.04.23.002
Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PRESSURE REDUCING
PRESSURE REDUCING AND
AND RELIEVING,
RELIEVING,
DIRECT ACTING SPOOL TYPE
DIRECT ACTING SPOOL TYPE
COMMON CAVITY
COMMON CAVITY
VRPR-10A SIZE 10 04.95.04
04.95.04 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure (*): 5000 psi (350 bar)
3 3
Int. leakage ave. : 3 in /min (50 cm /min)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (reduc. mode)
30-200 29 115-145
01 (2-14) (2) (8-10)
30-350 44 100-145
02 (2-25) (3) (7-10)
145-725 102 500-580 11.04.23.004
04 (10-50) (7) (35-40) Tamper resistant cap
400-1160 203 650-725
08 (28-80) (14) (45-50)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Special Valves
VPN1
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, HOSE BURST CHECK, HOSE BURST
TECHNICAL DATA
Max. pressure: 4500 psi (315 bar)
Flow: see below graphs (‘R’-Q)
Special flow settings available. Please contact factory
authorized representative for ordering code.
Note: on request are available as “in line mounted sleeves
type configuration”. Please contact factory for any
information.
The valve is only supposed to be operated in case of
hose failure. Should this circumstance occur, we
strongly recommend to verify the integrity of the valve
and eventually to replace it in the event that the
pressure spike generated by the hose failure was such
to damage permanently some valve components.
When the lowering speed exceeds preset value, as it might happen in case of hose
failure, the flow is blocked. These valves should ideally be screwed directly into the
actuator outlet port. Sealing parts are superfinished and enable to lock the load in the X ADJUSTMENTS
position where the actuator is in the moment of hose failure. These valves can be
Locking nut + counter nut
supplied, on request, with an orifice on the disc, allowing an emergency lowering of 03 see graphs (‘R’ - Q)
the load. It is recommended to fit a flow regulator valve downstream the hose burst
valve, at the end of the flexible hose, to control the lowering speed at the nominal
value. The “R” gap must be adjusted to allow a flow at least 50% over the nominal
regulated flow from the actuator.
Y PORTS
09 G 1/4
02 G 3/8
03 G 1/2
04 G 3/4
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Check Valves
VUH1
VSON-08A
VSON-10A
VSON-12A
VSON-16A
VUCN-08A
VUCN-10A
VUCN-12A
VUCN-16A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET
CHECK, POPPET TYPE
TYPE
VUH1
VUH1 0T.U5.01.00 --YY--ZZ
0T.U5.01.00
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
When pressure at 1 rises above the spring bias pressure, the poppet is lifted and flow
allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining
and hardening processes allow virtually leak-free performance in the checked
condition.
Cracking pressure
Z psi (bar) Y PORTS
02 G 3/8
03 G 1/2
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED CHECK,PILOT
PILOTOPERATED
TO OPEN CHECK, PILOT TO OPEN
COMMON CAVITY COMMON CAVITY
VSON-08A SIZE 08
VSON-08A 04.33.06 - XSIZE
- 5608
-Z 04.33.06 - X - 56 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
00 No O-Ring
10 With O-Ring
SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED
PILOT OPERATED CHECK,
CHECK, PILOT
PILOT TO
TO OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VSON-10A
VSON-10A SIZE 10 04.33.05
04.33.05 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
00 No O-Ring
10 With O-Ring
SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED CHECK,PILOT
PILOTOPERATED
TO OPEN CHECK, PILOT TO OPEN
COMMON CAVITY COMMON CAVITY
VSON-12A SIZE 12
VSON-12A 04.33.07 - XSIZE
- 5712
-Z 04.33.07 - X - 57 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
00 No O-Ring
10 With O-Ring
SPRINGS
Z Cracking pressure
psi
(bar)
30
00 (2)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
PILOT OPERATED
PILOT OPERATED CHECK,
CHECK, PILOT
PILOT TO
TO OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VSON-16A
VSON-16A SIZE 16 04.33.08
04.33.08 -- X
X -- 27
27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
00 No O-Ring
10 With O-Ring
SPRINGS
Z Cracking pressure
psi
(bar)
22
00 (1.5)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY
VUCN-08A SIZE 08
VUCN-08A 04.31.20.00.56
SIZE -08
Z 04.31.20.00.56 - Z
TECHNICAL DATA
Max. pressure: 6000 psi (420 bar)
/LQHERGLHVVHHSDJH01$«
SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
39
03 (2.7)
75
05 (5)
200
14 (14)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY
VUCN-10A SIZE 10
VUCN-10A 04.31.23.00.85
SIZE -10
Z 04.31.23.00.85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
SPRINGS
Z Cracking pressure
psi
(bar)
7
00 (0.5)
75
05 (5)
220
15 (15)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET
CHECK, POPPET TYPE
TYPE
COMMON CAVITY
COMMON CAVITY
VUCN-12A
VUCN-12A SIZE 12 04.31.28.00.57
04.31.28.00.57 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
75
05 (5)
220
15 (15)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY
VUCN-16A SIZE 16
VUCN-16A 04.31.25.00.27
SIZE -16
Z 04.31.25.00.27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
30
02 (2)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Counterbalance Valves
VBSN-08AA
VBSN-10A
VBSN-12A
VBSN-16A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD GUIDED POPPET
COUNTERBALANCE, TYPE
STANDARD GUIDED POPPET TYPE
COMMON CAVITY COMMON CAVITY
VBSN-08AA SIZE 08
VBSN-08AA 04.52.20 - XSIZE
- 56 08
-Z 04.52.20 - X - 56 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH$±$
X PILOT RATIO
03 4:1
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-2200 1051 2200
15 (70-150) (72.5) (150)
03.51.01.329
1450-3000 1581 2900
20 (100-210) (109) (200)
03.51.01.328
2900-5000 1987 5000 11.04.23.002
35 (200-350) (137) (350)
03.51.01.327
Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD
COUNTERBALANCE, STANDARD POPPET
POPPET TYPE
TYPE
DIFFERENTIAL AREA
DIFFERENTIAL AREA
COMMON CAVITY
COMMON CAVITY
VBSN-10A
VBSN-10A SIZE 10 04.52.31
04.52.31 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X PILOT RATIO
03 3:1
10 8:1
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 1958 2900
20 (70-210) (135) (200)
X = 03 2000-5000 2842 5000
35 (140-350) (196) (350)
1000-3000 754 2900 11.04.23.002
20 (70-210) (52) (200) Tamper resistant cap
X = 10 2000-5000 1291 5000
35 (140-350) (89) (350)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD POPPET TYPESTANDARD POPPET TYPE
COUNTERBALANCE,
DIFFERENTIAL AREA DIFFERENTIAL AREA
COMMON CAVITY COMMON CAVITY
VBSN-12A SIZE 12
VBSN-12A 04.52.28 - XSIZE
- 5712
-Z 04.52.28 - X - 57 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X PILOT RATIO
03 4:1
10 8:1
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 725 2900
20 (70-210) (50) (200)
X = 03 2000-5000 2306 5000
35 (140-350) (159) (350)
1000-3000 609 2900 11.04.23.002
20 (70-210) (42) (200) Tamper resistant cap
X = 10 2000-5000 972 5000
35 (140-350) (67) (350)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
COUNTERBALANCE, STANDARD
COUNTERBALANCE, STANDARD POPPET
POPPET TYPE
TYPE
DIFFERENTIAL AREA
DIFFERENTIAL AREA
COMMON CAVITY
COMMON CAVITY
VBSN-16A
VBSN-16A SIZE 16 04.52.29
04.52.29 -- X
X -- 27
27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X PILOT RATIO
03 4:1
10 8:1
SPRINGS OPTIONS
Z Adj. press. Press. increase Standard setting
range psi psi / turn psi (bar) Ordering code Description
(bar) (bar/turn) (Q=5 l/min)
1000-3000 1015 2900
20 (70-210) (70) (200)
X = 03 2000-5000 1566 5000
35 (140-350) (108) (350)
2000-6000 1958 5000 11.04.23.004
X = 10 40 (140-420) (135) (350) Tamper resistant cap
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Flow Control Valves
STVU-08A
VRFB-10A
VRFD-10
DRFN-10A
ST-C-06
ST-C-10A
ST-C-12A
ST-C-16A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
NEEDLE RESTRICTOR,
NEEDLE RESTRICTOR, FREE
FREE REVERSE
REVERSE FLOW
FLOW
COMMON CAVITY
COMMON CAVITY
STVU-08A
STVU-08A SIZE 08 04.01.02
04.01.02 -- X
X -- 56.00
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X ADJUSTMENTS
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL, 2-WAY PRESSURE COMPENSATED
FLOW CONTROL, 2-WAY PRESSURE COMPENSATED
FULLY ADJUSTABLE FULLY ADJUSTABLE
COMMON CAVITY COMMON CAVITY
VRFB-10A SIZE 10
VRFB-10A 04.02.02 - XSIZE
- 8510
-Z 04.02.02 - X - 85 - Z
TECHNICAL DATA
Pressure min-max: 200-5000 psi (14-350 bar)
X ADJUSTMENTS
40 Calibrated handknob
04 Handknob
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL, 3-WAY PRESSURE COMPENSATED
FLOW CONTROL, 3-WAY PRESSURE COMPENSATED
COMBINATION TYPE FULLY ADJUSTABLE
COMBINATION TYPE FULLY ADJUSTABLE
COMMON CAVITY COMMON CAVITY
VRFD-10A SIZE 10
VRFD-10A 04.04.02 - XSIZE
- 8510
-Z 04.04.02 - X - 85 - Z
TECHNICAL DATA
Pressure min-max: 200-5000 psi (14-350 bar)
X ADJUSTMENTS
40 Calibrated handknob
04 Handknob
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW DIVIDER
FLOW DIVIDER AND
AND COMBINER
COMBINER
COMMON CAVITY
COMMON CAVITY
DRFN-10A
DRFN-10A SIZE 10 04.05.01.00.85
04.05.01.00.85 - Z
TECHNICAL DATA
Pressure min-max: 145-5000 psi (10-350 bar)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL VALVES FLOW CONTROL VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY COMMON CAVITY
ST-C-06 SIZE 08
ST-C-06 OD.21.01 SIZE
- X - 56
08 OD.21.01 - X - 56
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
3.7 ft-lb (5 Nm)
at 5000 psi (350 bar)
X ORDERING OPTIONS
03 Socket Screw
Rev.06.05 3.11.010.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL
FLOW CONTROL VALVES
VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY
COMMON CAVITY
ST-C-10A
ST-C-10A SIZE 10 OD.21.01
OD.21.01 -- XX -- 36
36
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
7.4 ft-lb (10 Nm)
at 5000 psi (350 bar)
X ORDERING OPTIONS
03 Socket Screw
Rev.06.05 3.15.020.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
FLOW CONTROL VALVES FLOW CONTROL VALVES
CARTRIDGE RESTRICTORS
CARTRIDGE RESTRICTORS
COMMON CAVITY COMMON CAVITY
ST-C-12A SIZE 12
ST-C-12A OD.21.01 SIZE
- X - 89
12 OD.21.01 - X - 89
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Filtration : 25 Pm nominal or
page 7.01.050
better
Adjustment Torque
0.7 ft-lb (1 Nm)
at 145 psi (10 bar)
Adjustment Torque
13.3 ft-lb (18 Nm)
at 5000 psi (350 bar)
X ORDERING OPTIONS
03 Socket Screw
Rev.06.05 3.15.030.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
CHECK, POPPET TYPE CHECK, POPPET TYPE
COMMON CAVITY COMMON CAVITY
VUCN-16A SIZE 16
VUCN-16A 04.31.25.00.27
SIZE -16
Z 04.31.25.00.27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
SPRINGS
Z Cracking pressure
psi
(bar)
15
00 (1)
30
02 (2)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Logic Elements
VLST-10A
VLST-16A
VLST-20A
VLSP-10A
VLSP-16A
VCSQ-16A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE CONTROL
PRESSURE CONTROL
WITH EXTERNAL PILOT
WITH EXTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLST-10A SIZE 10 04.84.01
04.84.01 -- X
X -- 85
85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
X = 00 115 ±15%
08 (8 ±15%)
30-115 15 60
X = 03 00 (2-8) (1) (4)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, FLOW AND PRESSURE
LOGIC CONTROL
ELEMENT, FLOW AND PRESSURE CONTROL
WITH EXTERNAL PILOT WITH EXTERNAL PILOT
COMMON CAVITY COMMON CAVITY
VLST-16A VLST-16A
SIZE 16 04.84.01 - XSIZE
- 27 16
-Z 04.84.01 - X - 27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
123 ±15%
08 (8.5 ±15%)
X = 00 175 ±10%
12 (12 ±10%)
218 ±10%
15 (15 ±10%)
60-175 22 60
X = 03 00 (4-12) (1.5) (4)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE CONTROL
PRESSURE CONTROL
WITH EXTERNAL PILOT
WITH EXTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLST-20A SIZE 20 04.84.01
04.84.01 -- X
X -- 58
58 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking press.
psi
(bar)
80
05 (5.5)
167
11 (11.5)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, FLOW AND PRESSURE
LOGIC CONTROL
ELEMENT, FLOW AND PRESSURE CONTROL
WITH INTERNAL PILOT WITH INTERNAL PILOT
COMMON CAVITY COMMON CAVITY
VLSP-10A SIZE 10
VLSP-10A 04.84.03 - XSIZE
- 8510
-Z 04.84.03 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
X = 00 115 ±15%
08 (8 ±15%)
30-115 15 60
X = 03 00 (2-8) (1) (4)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT,
LOGIC ELEMENT, FLOW
FLOW AND
AND PRESSURE
PRESSURE CONTROL
CONTROL
WITH INTERNAL PILOT
WITH INTERNAL PILOT
COMMON CAVITY
COMMON CAVITY
VLSP-16A SIZE 16 04.84.03
04.84.03 -- X
X -- 27
27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH01$«
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking press. Press. increase Standard setting
psi psi / turn psi
(bar) (bar/turn) (bar)
60 ±20%
04 (4 ±20%)
115 ±15%
X = 00 08 (8 ±15%)
175 ±10%
12 (12 ±10%)
60-175 22 60
X = 03 00 (4-12) (1.5) (4)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
LOGIC ELEMENT, PRESSURE COMPENSATOR
LOGIC ELEMENT, PRESSURE COMPENSATOR
COMBINATION TYPE COMBINATION TYPE
COMMON CAVITY COMMON CAVITY
VCSQ-16A VCSQ-16A
SIZE 16 04.84.06 - XSIZE
- 27 16
-Z 04.84.06 - X - 27 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
/LQHERGLHVVHHSDJH$±$
Flow is normally allowed from 4 to 3. When pilot pressure at 1 rises above the
combined pressure of the spring bias, plus pressure at 4, the valve shifts to block External seal kit : see page A11.012
flow between 3 and 4, while diverting flow from 1 to 2. A constant pressure drop is
maintained across a fixed (or variable) orifice upstream of 4 when installed and Installation torque : 80-90 ft-lb (108-122 Nm)
piloted per the diagram above. In this case, flow priority is given to 3, with flow in
excess of the orifice differential requirement being by-passed to 2.
Weight: 1.654 lbs (0.750 Kg)
X ADJUSTMENTS
00 Fixed setting
SPRINGS
Z Cracking pressure
psi
(bar)
90
06 (6)
Rev.0208
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Directional Valves, Mechanically Operated.
VDSD-10A
VDP-32
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL SPOOL TYPE,
DIRECTIONAL SPOOL TYPE,
DIRECT ACTING EXTERNAL PILOT ACTING
DIRECT EXTERNAL VENT PILOT EXTERNAL VENT
EXTERNAL
COMMON CAVITY COMMON CAVITY
VDSD-10A VDSD-10A
SIZE 10 04.77.22 - XSIZE
- 8510
-Z 04.77.22 - X - 85 - Z
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
3 3
Int. leakage ave. : 1.5 in /min (25 cm /min)
Pilot displacement 3 3
0.02 in (0.28 cm )
volume:
/LQHERGLHVVHHSDJH01$«
Flow is allowed bi-directionally between 2 and 3 until pressure at 1 rises to overcome
the spring bias against the spool. When this bias pressure is surpassed, the spool External seal kit : see page A11.011
shifts, blocking flow at both 2 and 3. The spring chamber is sealed and vented to
atmosphere, allowing consistent shifting with only spring bias pressure independent
Installation torque : 30-35 ft-lb (41-47 Nm)
of conditions at 2 or 3.
00 No O-Ring
10 With O-Ring
SPRINGS
Z Setting
psi
(bar)
80 r20%
05 (5.5 r20%)
167 r10%
11 (11.5 r10%)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL CONTROL VALVES
HYDRAULIC AUTOMATIC SWITCHING
SPOOL 3-WAY 2-POSITION CARTRIDGE STYLE
VDP-32 OD.71.01.51 - Z
Hex. 24
Torque 39-51 Nm
TECHNICAL DATA
Maximum Operating
315 bar
Pressure
Rated Flow 30 l/min
Weight 0.195 kg
300 7
PRESSURE - ǻp (bar)
PRESSURE - ǻp (bar)
250 6
5
200
4
150
3
100
2
50 1
0 0
0 5 10 15 20 25 30 35
FLOW - Q (l/min)
SWITCHING PRESSURE
bar
Z
Adj. pressure
Standard setting
range
01 3-25 5
02 20-60 35
04 70-100 90
Rev.03.03 2.43.010.G
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Shuttle Valves
VFC
SELB-08A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SHUTTLE
VFC 05.99.05.00 - Y
TECHNICAL DATA
Aluminium body
NOTE: aluminium bodies are often strong enough for operating
pressures exceeding 210 bar (3000 psi), depending from the
fatigue life expected in the specific application. If in doubt,
consult our Service Network.
PORT SIZE
Y
V1-V2-C
09 G 1/4
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Solenoide Valves
VED-8I-32- VEI-8A-2A-10A-
06-SE NC-S-NSS
VED-8I-32- VEI-8A-2A-10A-
06-SI NC-S-X-NSS
VED-8I-32- VEI-8A-2A-12-
06-NC NA-S-NSS
VED-8I-42- VEI-8A-2A-12-
06-CA NC-S-X-NSS
VEI-8A-2A-12A-
VED-8I-43-
NA-S-NSS
06-ABT
VEI-8A-2A-06- VEI-8A-2T-06-
NA-S-NSS NA-S-NSS
VEI-8A-2T-06-
VEI-8A-2A-06- NC-S-NSS
NC-S-X-NSS
VEI-8I-2A-06-
VEI-8A-2A-09- NC-S-NSS
NA-S-NSS
VEI-8I-2A-06-
VEI-8A-2A-09-
NC-S1-NSS
NC-S-X-NSS
VEI-8A-2A-10A- VEI-8I-2A-06-
NA-S-NSS NC-S1-NSS, N9
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
DIRECTIONAL POPPET TYPE,
DIRECTIONAL POPPET TYPE,
SHUTTLE SHUTTLE
COMMON CAVITY COMMON CAVITY
SELB-08A SIZE 08
SELB-08A 04.94.05.00.56.00
SIZE 08 04.94.05.00.56.00
TECHNICAL DATA
Max. pressure: 5000 psi (350 bar)
Nominal size DN 3
/LQHERGLHVVHHSDJH01$«
Rev.0606
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-SE
VED-8I-32-06-SE SIZE 08 OD.13.10.51
OD.13.10.51 -- Y
Y -- 00
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure
Y ORDERING OPTIONS
30 Standard
Rev.06.05 1.31.050.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-SI
VED-8I-32-06-SI SIZE 08 OD.13.11.51
OD.13.11.51 -- Y
Y -- 00
00
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure
Port 1 can be pressurized but is not intended to be used as inlet port. Testing Conditions - Seals page 7.01.040
Y ORDERING OPTIONS
30 Standard
Rev.06.05 1.31.100.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 3-WAY 2-POSITION
SPOOL 3-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-32-06-NC
VED-8I-32-06-NC SIZE 08 OD.13.20.51
OD.13.20.51 -- Y
Y -- 00
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure
Y ORDERING OPTIONS
30 Standard
Rev.06.05 1.31.150.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 4-WAY 2-POSITION
SPOOL 4-WAY 2-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-42-06-CA
VED-8I-42-06-CA SIZE 08 OD.14.40.58
OD.14.40.58 -- YY -- 00
00
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
3000 psi (210 bar)
Pressure
Y ORDERING OPTIONS
30 Standard
Rev.06.05 1.41.050.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
SPOOL 4-WAY 3-POSITION
SPOOL 4-WAY 3-POSITION
COMMON CAVITY
COMMON CAVITY
VED-8I-43-06-ABT
VED-8I-43-06-ABT SIZE 08 OD.14.32.58
OD.14.32.58 -- YY -- 00
00
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
Y ORDERING OPTIONS
44 Standard
Rev.06.05 1.43.150.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-06-NA-S-NSS
VEI-8A-2A-06-NA-S-NSS SIZE 08 OD.15.06.18
OD.15.06.18 -- Y
Y -- S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.06.05 1.12B.060.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED - EXTRA
2-WAY SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
017-E OD.15.05.17017-E
VEI-8A-2A-09-NC-S-X-NSSVEI-8A-2A-09-NC-S-X-NSS - Y - S8 OD.15.05.17 - Y - S8
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH016«
Y ORDERING OPTIONS
3A Standard
Rev.10.08 1.11B.465.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-10A-NA-S-NSS
VEI-8A-2A-10A-NA-S-NSS SIZE 10 OD.15.06.36
OD.15.06.36 -- YY -- S0
S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.06.05 1.16B.460.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED - EXTRA
2-WAY SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
017-E OD.15.05.17017-E
VEI-8A-2A-09-NC-S-X-NSSVEI-8A-2A-09-NC-S-X-NSS - Y - S8 OD.15.05.17 - Y - S8
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH016«
Y ORDERING OPTIONS
3A Standard
Rev.10.08 1.11B.465.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-10A-NA-S-NSS
VEI-8A-2A-10A-NA-S-NSS SIZE 10 OD.15.06.36
OD.15.06.36 -- YY -- S0
S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.06.05 1.16B.460.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 10 OD.15.05.36SIZE
VEI-8A-2A-10A-NC-S-NSS VEI-8A-2A-10A-NC-S-NSS - Y -10
S0 OD.15.05.36 - Y - S0
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH01$«
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
3A Standard
Rev.02.07 1.15B.460.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVESSOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY
- EXTRA SPRING CLOSED - EXTRA SPRING
NORMALLY
COMMON CAVITY COMMON CAVITY
SIZE 10 OD.15.05.36SIZE
VEI-8A-2A-10A-NC-S-X-NSSVEI-8A-2A-10A-NC-S-X-NSS - Y -10
S8 OD.15.05.36 - Y - S8
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH01$«
Y ORDERING OPTIONS
3A Standard
Rev.02.07 1.15B.465.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
OPEN 2-WAY NORMALLY OPEN
SPECIAL CAVITY SPECIAL CAVITY
021-E OD.15.06.21021-E
VEI-8A-2A-12-NA-S-NSS VEI-8A-2A-12-NA-S-NSS - Y - S0 OD.15.06.21 - Y - S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.09.05 1.12B.660.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY
- EXTRA SPRING CLOSED - EXTRA SPRING
NORMALLY
SPECIAL CAVITY SPECIAL CAVITY
OD.15.05.21021-E
VEI-8A-2A-12-NC-S-X-NSS
VEI-8A-2A-12-NC-S-X-NSS 021-E - Y - S8 OD.15.05.21 - Y - S8
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH016«
Y ORDERING OPTIONS
3A Standard
Rev.02.07 1.11B.665.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY NORMALLY
POPPET 2-WAY NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2A-12A-NA-S-NSS
VEI-8A-2A-12A-NA-S-NSS SIZE 12 OD.15.06.89
OD.15.06.89 -- YY -- S0
S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.06.05 1.16B.660.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
POPPET 2-WAY DOUBLE
POPPET 2-WAY DOUBLE LOCK
LOCK NORMALLY
NORMALLY OPEN
OPEN
COMMON CAVITY
COMMON CAVITY
VEI-8A-2T-06-NA-S-NSS
VEI-8A-2T-06-NA-S-NSS SIZE 08 OD.15.32.18
OD.15.32.18 -- YY -- S0
S0
PATENT PENDING
2.2-3.0 ft-lb
(3-4) Nm
Coil S8-356
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
1A Standard
Rev.06.05 1.14B.060.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY DOUBLE LOCK NORMALLY
POPPET CLOSEDLOCK NORMALLY CLOSED
2-WAY DOUBLE
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.31.18SIZE
VEI-8A-2T-06-NC-S-NSSVEI-8A-2T-06-NC-S-NSS - Y -08
S0 OD.15.31.18 - Y - S0
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH01$«
Filtration : 25 Pm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
3A Standard
Rev.02.07 1.13B.060.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.05.18SIZE
VEI-8I-2A-06-NC-S-NSS VEI-8I-2A-06-NC-S-NSS - Y -08
S0 OD.15.05.18 - Y - S0
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH01$«
Filtration : 25 µm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
3I Standard
Rev.01.07 1.11B.050.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
POPPET 2-WAY NORMALLYPOPPET
CLOSED2-WAY NORMALLY CLOSED
COMMON CAVITY COMMON CAVITY
SIZE 08 OD.15.01.18SIZE
VEI-8I-2A-06-NC-S1-NSSVEI-8I-2A-06-NC-S1-NSS - Y -08
S0 OD.15.01.18 - Y - S0
PATENT PENDING
TECHNICAL DATA
Maximum Operating
5000 psi (350 bar)
Pressure
Fatigue Cycle Life at
5000 psi (350 bar) and 0.5 Hz 10 million cycles
(1 s ON - 1 s OFF)
/LQHERGLHV SDJH01$«
Filtration : 25 µm nominal or
page 7.01.050
better
Y ORDERING OPTIONS
3I Standard
Rev.01.07 1.11B.030.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED VALVES
SOLENOID OPERATED VALVES
CONTINUOUS DUTY COILSCONTINUOUS
- ED 100% DUTY COILS - ED 100%
OD.02.17
S8-356 SERIES - CLASS H S8-356 SERIES - CLASS H -X-Y-Z OD.02.17 - X - Y - Z
TECHNICAL DATA
General coil information page 7.01.010
HEAT INSULATION
356 qF (180 qC)
CLASS H
-86 +140 (-30 +60
Ambient temperature range
°F °C)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SOLENOID OPERATED
SOLENOID OPERATED VALVES
VALVES
CONTINUOUS DUTY COILS -- ED
CONTINUOUS DUTY COILS ED 100%
100%
S8-356SERIES
S8-356 SERIES--CLASS
CLASSHH OD.02.17
OD.02.17 -- X
X -- Y
Y -- Z
TECHNICAL DATA
General coil information page 7.01.010
Rev.06.05 1.71.043.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
STANDARD
COMMON CAVITY COMMON CAVITY
CAVITY CA-08A-2N
FEATURES
3600 psi
MAX. PRESSURE Standard manifolds in high-strength aluminum
(250 bar) for working pressures up to 3600 psi (250 bar).
Rev.07.06 MN2.A.001.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
COMMON CAVITY
COMMON CAVITY
22WAY
WAYSTEEL
STEEL SIZE
SIZE 08
08
CAVITY CA-08A-2N
FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.
Rev.05.05 MN2.A.002.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
STANDARD
COMMON CAVITY COMMON CAVITY
SIZE
3 WAY 4 WAY ALUMINIUM3 WAY 08 ALUMINIUM
4 WAY SIZE 08
CAVITY CA-08A-3N
CAVITY CA-08A-4N
0.331
OC.10.09.046 G 3/8
(0.150)
FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).
Rev.07.06 MN2.A.003.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD
STANDARD MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
COMMON CAVITY
COMMON CAVITY
33 WAY
WAY 4
4 WAY
WAY ALUMINIUM
ALUMINIUM SIZE
SIZE 10
10
CAVITY CA-10A-3N
CAVITY CA-10A-4N
0.375
OC.10.09.118 G 3/8
(0.170)
FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).
Rev.07.06 MN2.A.004.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
SPECIAL CAVITY SPECIAL CAVITY
CAVITY 017-E
Dimensions on page CT.S.005.U
0.441
OC.10.09.012 G 3/4
(0.200)
CAVITY 021-E
Dimensions on page CT.S.005.U
FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).
Rev.07.06 MN2.S.001.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS (SECTION 2) MANIFOLDS (SECTION 2)
SPECIAL CAVITY SPECIAL CAVITY
CAVITY 019-E
Dimensions on page CT.S.005.U
CAVITY 004
Dimensions on page CT.S.001.U
2.646
OC.10.09.041 G 1-1/4
(1.200)
CAVITY 081-E
Dimensions on page CT.S.005.U
FEATURES
3600 psi Standard manifolds in high-strength aluminum
MAX. PRESSURE
(250 bar) for working pressures up to 3600 psi (250 bar).
Rev.07.06 MN2.S.003.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
SPECIAL CAVITY
SPECIAL CAVITY
22WAY
WAYSTEEL
STEEL
CAVITY 017-E
Dimensions on page CT.S.005.U
1.984
OC.10.09.073 G 3/4
(0.900)
CAVITY 021-E
Dimensions on page CT.S.005.U
FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.
Rev.05.05 MN2.S.002.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
MANIFOLDS
MANIFOLDS (SECTION
(SECTION 2)
2)
SPECIAL CAVITY
SPECIAL CAVITY
22WAY
WAYSTEEL
STEEL
CAVITY 019-E
Dimensions on page CT.S.005.U
CAVITY 004
Dimensions on page CT.S.001.U
7.716
OC.10.09.056 G 1-1/4
(3.500)
CAVITY 081-E
Dimensions on page CT.S.005.U
FEATURES
6500 psi
MAX. PRESSURE These manifolds can be supplied upon request
(450 bar) for working pressures up to 6500 psi (450 bar)
and for fatigue cycle applications.
Rev.05.05 MN2.S.004.U
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY
CA-xxx-2N
CA-xxx-2N
G 3/4 60 70 40 30 15 55 9 20 9 03.30.05.226
9/16-18 60 60 35 25 15 45 7 19 7 03.30.05.180 03.30.05.181
3/4-16 60 60 35 25 15 45 7 19 7 03.30.05.182 03.30.05.183
7/8-14 60 60 35 25 15 45 7.5 19 7 03.30.05.247 03.30.05.248
G 1/2 75 80 40 35 20 60 10 26.5 9 03.30.05.228 03.30.05.229
G 3/4 75 80 40 35 20 60 10 26.5 9 03.30.05.289 03.30.05.290
CA-12A-2N
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 1) MANIFOLDS (SECTION 1)
STANDARD
COMMON CAVITY COMMON CAVITY
CA-xxx-3C CA-xxx-3C
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY
CA-xxx-3N
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS (SECTION 1) MANIFOLDS (SECTION 1)
STANDARD
COMMON CAVITY COMMON CAVITY
CA-xxx-4N CA-xxx-4N
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD MANIFOLDS
STANDARD MANIFOLDS (SECTION
(SECTION 1)
1)
COMMON CAVITY
COMMON CAVITY
CA-xxx-4N
G 3/8 75 60 35 30 15 50 10 19 35 51 7 03.30.05.210
CA-10A-4N
CA-12A-4N
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIESSTANDARD
- TOOLS CAVITIES - TOOLS
DRILL
Ø G1 Ø G1 Ø G1 Ø G1 Ø G1
FORM DRILL
FORM REAMER
PLUG TAP
* NOTE: Special heavy duty tools are available upon request, for steel drilling.
inches (mm)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIESSTANDARD
- TOOLS CAVITIES - TOOLS
DRILL
Ø G1 Ø G1 Ø G1 Ø G1 Ø G1
FORM DRILL
FORM REAMER
PLUG TAP
* NOTE: Special heavy duty tools are available upon request, for steel drilling.
inches (mm)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIES
STANDARD CAVITIES - TOOLS
DRILL
Ø G2 Ø G2 Ø G2 Ø G2 Ø G2
FORM DRILL
FORM REAMER
PLUG TAP
* NOTE: Special heavy duty tools are available upon request, for steel drilling.
inches (mm)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
STANDARD CAVITIES - TOOLS
STANDARD
DRILL
Ø G1 Ø G1 Ø G1 Ø G1 Ø G1
FORM DRILL
FORM REAMER
PLUG TAP
* NOTE: Special heavy duty tools are available upon request, for steel drilling.
inches (mm)
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES
003 004
005 006
008 009
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL
SPECIAL CAVITIES
CAVITIES
033 059
063 065
072 137
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES
348 416
625 690
730 730-A
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES
SPECIAL CAVITIES
771 808
869 870
871
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL CAVITIES SPECIAL CAVITIES
CA-07A-3N CC063A-01
CD072A-01 CD073A-01
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
SPECIAL
SPECIAL CAVITIES
CAVITIES
017-E 019-E
021-E 081-E
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Preferred
Group BROC Catalog Code BROC Ident Denomination Rexroth Code
Type
04.11.49.03.56.10.000 relief, direct acting guided poppet type, common cavity R901113599 X
VSBN-08A 04.11.49.03.56.20.000 relief, direct acting guided poppet type, common cavity R901097728 X
04.11.49.03.56.35.000 relief, direct acting guided poppet type, common cavity R901091914 X
04.11.55.03.85.10.000 relief, direct acting guided poppet type, common cavity R901113609 X
VSBN-10A 04.11.55.03.85.20.000 relief, direct acting guided poppet type, common cavity R901113610 X
04.11.55.03.85.35.000 relief, direct acting guided poppet type, common cavity R901115702 X
04.11.56.03.85.10.000 relief, direct acting guided poppet type, common cavity R901113622 X
VSBG-10A 04.11.56.03.85.20.000 relief, direct acting guided poppet type, common cavity R901113624 X
04.11.56.03.85.35.000 relief, direct acting guided poppet type, common cavity R901113626 X
04.11.59.03.85.10.000 relief, bidirectional, direct acting poppet type differential area, common cavity R901109725
Pressure Control Valves VSNG - 10A
04.11.59.03.85.20.000 relief, bidirectional, direct acting poppet type differential area, common cavity R901109726
04.12.08.03.85.20.000 relief, pilot operated, spool type, common cavity R901097722
VSPN - 10A
04.12.08.03.85.35.000 relief, pilot operated, spool type, common cavity R901104103
04.13.05.03.85.10.000 pilot operated sequence valve, spool type, external drain, common cavity R901106472 X
VSPY - 10A
04.13.05.03.85.20.000 pilot operated sequence valve, spool type, external drain, common cavity R901097730
VRPP - 10A 04.93.06.03.85.10.000 pressure reducing, pilot operated, spool type, common cavity R901104112 X
VRPX - 10A 04.93.07.03.85.10.000 pressure reducing and relieving, pilot operated spool type, common cavity R901104118
04.95.04.03.85.02.00A pressure reducing and relieving, direct acting spool type, common cavity R901109740
VRPR - 10A 04.95.04.03.85.04.00A pressure reducing and relieving, direct acting spool type, common cavity R901102333 X
04.95.04.03.85.08.00A pressure reducing and relieving, direct acting spool type, common cavity R901109742 X
0T.F4.01.03.03.00.000 hose burst R901127828
0T.F4.01.03.09.00.000 hose burst R931000021
Special Valves VPN1
0T.F4.01.03.04.00.000 hose burst R901161819
0T.F4.01.03.02.00.000 hose burst R931000017
0T.U5.01.00.03.00.000 check, poppet type R901087794
VUH1
0T.U5.01.00.02.00.000 check, poppet type R901064101
VSON - 08A 04.33.06.00.56.00.000 pilot operated check, common cavity R901106627 X
VSON - 10A 04.33.05.00.85.00.000 pilot operated check, common cavity R901106629 X
VSON - 12A 04.33.07.00.57.00.000 pilot operated check, common cavity R901092653 X
VSON - 16A 04.33.08.00.27.00.000 pilot operated check, common cavity R901106635
Check Valves 04.31.20.00.56.00.000 check poppet type, 1 bar cracking, common cavity R901007308 X
VUCN - 08A
04.31.20.00.56.05.000 check poppet type, 5 bar cracking, common cavity R901106550 X
04.31.23.00.85.00.000 check poppet type, 1 bar cracking, common cavity R901106596 X
VUCN - 10A
04.31.23.00.85.05.000 check poppet type, 5 bar cracking, common cavity R901106601 X
04.31.28.00.57.00.000 check poppet type, 1 bar cracking, common cavity R901106613 X
VUCN - 12A
04.31.28.00.57.05.000 check poppet type, 5 bar cracking, common cavity R901106614
VUCN - 16A 04.31.25.00.27.00.000 check poppet type, common cavity R901106616
04.52.20.03.56.20.000 counterbalance, std. guided poppet type, common cavity R901095960
VBSN - 08AA
04.52.20.03.56.35.000 counterbalance, std. guided poppet type, common cavity R901095961
04.52.31.03.85.35.000 counterbalance, std. poppet type, diff area, 3:1, 140 - 350bar, common cavity R901096037
VBSN - 10A
04.52.31.03.85.20.000 counterbalance, std. poppet type, diff area, 3:1, 70 - 210bar, common cavity R901096029 X
Counterbalance Valves
04.52.28.03.57.35.000 counterbalance, std. poppet type, diff area, 4:1, 140 - 350bar, common cavity R901096044
VBSN - 12A
04.52.28.03.57.20.000 counterbalance, std. poppet type, diff area, 4:1, 70 - 210bar, common cavity R901096043 X
04.52.29.03.27.35.000 counterbalance, std. poppet type, diff area, 4:1, 140 - 350bar, common cavity R901096048
VBSN - 16A
04.52.29.03.27.20.000 counterbalance, std. poppet type, diff area, 4:1, 70 - 210bar, common cavity R901096047
04.01.02.03.56.00.000 needle restrictor with free reverse flow, common cavity R901109368 X
STVU - 08A
04.01.02.04.56.00.000 needle restrictor, free reverse flow, common cavity R901109839
VRFB-10A 04.02.02.04.85.40.000 flow control, 2-way pressure compensated, fully adjustable, common cavity R901095981 X
flow control, 3-way pressure compensated, combination type fully adjustable, common
VRFD-10 04.04.02.04.85.40.000 R901106675 X
cavity
04.05.01.00.85.16.000 flow divider and combiner, common cavity R901096083
Flow Control Valves DRFN - 10A 04.05.01.00.85.30.000 flow divider and combiner, common cavity R901096086
04.05.01.00.85.40.000 flow divider and combiner, common cavity R901096087
ST - C - 06 OD.21.01.03.56.00.000 cartridge restrictor, common cavity R901109366 X
OD.21.01.03.36.00.000 cartridge restrictor, common cavity R901109830 X
ST - C - 10A
OD.21.01.04.36.00.000 cartridge restrictor, common cavity R901109831 X
ST - C - 12A OD.21.01.03.89.00.000 cartridge restrictor, common cavity R901109832 X
ST - C - 16A OD.21.01.03.75.00.000 cartridge restrictor, common cavity R901109837 X
VLST-10A 04.84.01.03.85.00.000 Logic Element, adjustable, 2-8 bar, common cavity R901104079
VLST-16A 04.84.01.03.27.00.000 Logic Element, adjustable, 4-12 bar, common cavity R901109372
VLST-20A 04.84.01.00.58.11.000 Logic Element, fixed setting, 11,5 bar, common cavity R901109867
Logic Elements
VLSP-10A 04.84.03.03.85.00.000 Logic Element, adjustable, 2-8 bar, common cavity R901109375
VLSP-16A 04.84.03.03.27.00.000 Logic Element, adjustable, 4-12 bar, common cavity R901109871
VCSQ - 16A 04.84.06.00.27.06.000 logic element, pressure compensator, combination type, common cavity R901162013
VDSD - 10A 04.77.22.00.85.05.000 directional spool type, direct actig external pilot, external vented, common cavity R901109495
directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
OD.71.01.51.01.00.000 X
style, special cavity R979015064
Directional Valves,
Mechanically Operated. directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
VDP-32 OD.71.01.51.02.00.000 X
style, special cavity R979015065
directional control valves, hydraulic automatic switching, spool 3-way 2-position cartridge
OD.71.01.51.04.00.000 X
style, special cavity R979015066
VFC 05.99.05.00.09.00.00A shuttle 05990500090000A X
Shuttle Valves
SELB - 08A 04.94.05.00.56.00.000 shuttle, common cavity R901161981 X
OD.13.10.51.30.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126871 X
VED-8I-32-06-SE
OD.13.10.51.40.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126872 X
VED-8I-32-06-SI OD.13.11.51.30.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126873
VED-8I-32-06-NC OD.13.20.51.30.00.000 solenoid operated valves, spool 3-way 2-position, common cavity R901126892
VED-8I-42-06-CA OD.14.40.58.30.00.000 solenoid operated valves, spool 4-way 2-position, common cavity R901113693
VED-8I-43-06-ABT OD.14.32.58.44.00.000 solenoid operated valves, spool 4-way 3-position, common cavity R901113705
VEI - 8A - 2A - 06 -
OD.15.06.18.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901091130 X
NA - S - NSS
VEI - 8A - 2A - 06 -
OD.15.05.18.3A.S8.000 2/2 poppet directional valve, normally closed, extra spring, both way, common cavity R934003080
NC - S - X - NSS
VEI - 8A - 2A - 09 -
OD.15.06.17.1A.S0.000 2/2 poppet directional valve, normally open, both way, special cavity R901113677
NA - S - NSS
VEI - 8A - 2A - 09 -
OD.15.05.17.3A.S8.000 2/2 poppet directional valve, normally closed extra spring, both way, special cavity R901119220
NC - S - X - NSS
VEI - 8A - 2A - 10A -
OD.15.06.36.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901080489
NA - S - NSS
VEI - 8A - 2A - 10A -
OD.15.05.36.3A.S0.000 2/2 poppet directional valve, normally closed, both way, common cavity R901090947 X
Solenoid Valves NC - S - NSS
VEI - 8A - 2A - 10A -
OD.15.05.36.3A.S8.000 solenoid operate valves, poppet 2 way normally closed, extra spring, common cavity R901090945 X
NC - S - X - NSS
VEI - 8A - 2A - 12 -
OD.15.06.21.1A.S0.000 2/2 poppet directional valve, normally open, extra spring, both way, special cavity R901104409
NA - S - NSS
VEI - 8A - 2A - 12 -
OD.15.05.21.3A.S8.000 2/2 poppet directional valve, normally closed, extra spring, both way, special cavity R901119221
NC - S - X - NSS
VEI - 8A - 2A - 12A - OD.15.06.89.1A.S0.000 2/2 poppet directional valve, normally open, both way, common cavity R901091139
NA - S - NSS OD.15.06.89.1A.S0.001 2/2 poppet directional valve, normally open, both way, common cavity R901091140
VEI - 8A - 2T - 06 -
OD.15.32.18.1A.S0.000 2/2 poppet directional valve, normally open, double lock, both way, common cavity R901091171
NA - S - NSS
VEI - 8A - 2T - 06 -
OD.15.31.18.3A.S0.000 2/2 poppet directional valve, normally closed, double lock, both way, common cavity R901082015 X
NC - S - NSS
VEI-8I-2A-06-NC-S-
OD.15.05.18.3I.S0.000 solenoid operated valves, poppet 2-way normally closed, common cavity R901090953
NSS
VEI - 8I - 2A - 06 - NC
OD.15.01.18.3I.S0.000 2/2 poppet directional valve, normally closed, one way, common cavity R901090962 X
- S1 - NSS
VEI-8I-2A-06-NC-S1-
OD.15.01.18.3M.S0.000 solenoid operated valves, poppet 2-way normally closed, common cavity X
NSS, N9 R901090966
OD.02.17.01.30.OC.000 coil, 24VDC, Hirschmann R901083065 X
OD.02.17.01.30.OB.000 coil, 12VDC, Hirschmann R901090821 X
S8 - 356
OD.02.17.01.30.OW.000 coil, 110 V RAC R901087981 X
Coils
OD.02.17.01.30.OZ.000 coil, 220 V RAC, Hirschmann R901085466 X
OD.02.17.20.30.OC.000 coil, 24VDC, Deutsch connector R901094611 X
S8 - 356 2
OD.02.17.20.30.OB.000 coil, 12VDC, Deutsch connector R901094609 X
Manifolds Manifold OC.10.09.00.40.00.000 manifold 2 way aluminum R901082022
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]
Cartridge Valves - RC X BROC
BR RC Brazil BR Oil Control Cavity Interchange? Note
Group 01
Comercial Andaluza de Técnicas y Suministros, S.L. (CATS, S.L.) Málaga (España). Telf: +(34) 952 24 61 37 www.cats.es [email protected]