LIFT CONTROLLER
USER MANUAL
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
ARL-200S
ARKEL 2009 2
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
CONTENTS
1. ENTERING THE PROGRAM MENU ..................................................................................................................... 4
1.1 MANUAL MOVEMENT MODE....................................................................................................................... 4
1.2 GIVING CALLS BY KEYPAD ......................................................................................................................... 4
1.3 PROGRAM PARAMETERS .............................................................................................................................. 4
2. LIST OF PARAMETERS .......................................................................................................................................... 5
2.1 COMMAND TYPE ............................................................................................................................................ 5
2.2 NUBER OF FLOORS ......................................................................................................................................... 5
2.3 CAR CONNECTION.......................................................................................................................................... 5
2.4 AUTOMATIC DOOR......................................................................................................................................... 5
2.5 AUTOMATIC DOOR AT FLOOR .................................................................................................................... 5
2.6 CAR LAMP DELAY .......................................................................................................................................... 6
2.7 WAIT AT FLOOR .............................................................................................................................................. 6
2.8 PARKING FLOOR ............................................................................................................................................. 6
2.9 PARKING DELAY ............................................................................................................................................ 6
2.10 R. CAM DELAY .............................................................................................................................................. 6
2.11 MAX HIGH SPEED ......................................................................................................................................... 6
2.12 MAX LOW SPEED .......................................................................................................................................... 6
2.13 POSITION RESET ........................................................................................................................................... 6
2.14 CONTACTOR DELAY .................................................................................................................................... 6
2.15 RESERVE ......................................................................................................................................................... 6
2.16 CARE TIME ..................................................................................................................................................... 6
2.17 END OF CARE TIME ...................................................................................................................................... 7
2.18 PASSWORD ..................................................................................................................................................... 7
2.19 DIGITAL SETUP ............................................................................................................................................. 7
2.20 LIMITS AT INSP. ............................................................................................................................................ 7
2.21 SELECTOR TYPE............................................................................................................................................ 7
2.22 GROUP FUNCTION ........................................................................................................................................ 7
2.23 DOOR OPEN ERROR ...................................................................................................................................... 7
2.24 EXIT MENU ..................................................................................................................................................... 7
3. ARL-200S ERROR CODE......................................................................................................................................... 8
4. DIMENSIONS OF ARL-200 CONTROLLER .......................................................................................................... 9
ARL-200S
ARKEL 2009 3
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
Press the LEFT button for 3 seconds. If no password has been entered before (0000 : factory
default), the first parameter “COMMAND TYPE” is displayed on LCD . If a password has been
assigned before, you must enter the four digit password by pressing the UP and DOWN buttons.
Then press the RIGHT button.The first parameter is displayed.If the password is entered incorrect
an error massage “WRONG PASSWORD” will appear on the LCD.If the password is entered
incorrect for three times, the system gets blocked off. Six digits PUK CODE must be entered.
Press the RIGHT button for 3 seconds. “MANUAL MOVEMENT” message is displayed.You can
move the lift up and down by pressing UP and DOWN buttons. Press the LEFT button to leave the
MM Mode.
It is possible to give any call by using keypad. Press UP button to set a call to top floor and press
DOWN button to set a call to bottom floor on main screen.
You can pass through the parameters by pressing LEFT and RIGHT buttons and change the
parameter by pressing UP and DOWN buttons. When you change a parameter by pressing UP and
DOWN buttons, the new value for that parameter is recorded in the temporary memory. It is not
necesarry to press any key to record any changed parameter. All parameters are recorded to the
memory after leaving the program menu. If card’s power cut out and turned on again before
leaving the program menu, the parameters keep the older values.
ARL-200S
ARKEL 2009 4
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
2. LIST OF PARAMETERS
- SERIAL
FX_MB has an ability to communicate with a control card (FX_SERI) on the car via two cables
(S1A&S1B), when used some of the controls (Car calls ,7 Segment Display, Full Load , Over Load
. etc) are not connected from the car to the control panel..
-PARALLEL
All signals from the car to the panel are connected seperatly.
There is no need to use special cable or shielded cable for serial communication.
But it will be better if the first or last two of the flexible cable are used for S1A, S1B and high
voltages should be at the other side (far from S1A, S1B) of the flexible cable. If a communication
error occures, red error led on the FX_SERI control card will blink.
- Waits closed
- Waits opened
WARNING!!! Waits open is not allowed according the harmonized standard EN 81-1/2. So this
parameter must be set to “Waits closed” to fully fit EN81-1/2. The lifts at the countries which has
own standard other then EN81-2/2 or at the lifts that modernized and taken measures against risk of
doors waiting open can be set as “waits opened”.
ARL-200S
ARKEL 2009 5
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
If the serial communication board is used on inspection box and the OPEN/CLOSE button
signals are connected to serial communication board, increase this parameter and adjust the time
delay trimpot to zero on automatic door board. If car installation is parallel and door is full
automatic, set this parameter to 2 s and adjust the time delay trimpot to zero on automatic door
board.
2.15 RESERVE
ARL-200S does not use this parameter at this time.
ARL-200S
ARKEL 2009 6
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
2.18 PASSWORD
Password to enter program parameters.
- Direct Stop
- Go Floor level
Set this parameter to “GO FLOOR LEVEL” for systems with AKUS-SD evacuation unit.
ARL-200S
ARKEL 2009 7
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
CODE ERROR
H1 DOOR CAN NOT LOCKED ERROR
H2 CAN NOT REACH NEW FLOOR
H3 DOOR IS OPEN FOR A LONG TIME
H4 MAX LOW SPEED TIME OVERFLOW
H5 BOTH LIMITS ARE OPEN
H6 UP LIMIT OPEN WHILE GO DOWN
H7 DOWN LIMIT OPEN WHILE GO UP
H8 MOTOR PTC IS OPEN
H9 LIFT CARE TIME OVERFLOW
H10 CONTACTOR CHECKBACK ERROR
H11 -
H12 -
H13 -
H14 100 VOLTAGE UNDER LIMIT
H15 HIGH VOLTAGE.SHUTDOWN POWER
ARL-200S
ARKEL 2009 8
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
Front View
Keypad
160mm
170mm
LCD
221mm
231mm
Sideway View
20mm
Pcboard
Pcboard fitting screw
260mm
ARL-200S
ARKEL 2009 9
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
ATTENTION!
Take care while connecting
your flexible cable
There are small points to take care while connecting your flexible cable. Arrange your cable order
according to their electrical signal level. Although the cables have enough insulation, long parallel
cables have transformer effect. The signals can joint between each neighbors. If there is two or
more flexible cables it is better to separate low an high voltage signals.
In this example ever car lamp on/off operation makes high voltage peaks on line and it can leak to
406 (car call signal). In long term this cause a fault on 406 output transistor. Also there is risk
because of Magnetic cam power lines. 818 and 804 signal may have faulty operation in long term.
ARL-200S
ARKEL 2009 10
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
ARL-200 controller must receive the information about ADrive fault and can stop the operation. Otherwise, in the
case of a faulire ARL-200 controller thinks that the motor is still running and after a delay time blocks the lift with the
fault “CAN NOT REACH NEW FLOOR”. The contact of ADrive error relay (RHO-RHA) must be connected properly
according to electrical diagrams. 120, 130 and 140 indicators on controller must be turned of when the RHO-RHA
teminals is unplugged.
ARL-200S
ARKEL 2009 11
ARKEL Elektrik Elektronik Ltd. Şti. www.arkel.com.tr
ARL-200S
ARKEL 2009 12