FOUNDATION Fieldbus Linking Devices

1788-EN2FFR – EtherNet/IP to FOUNDATION Fieldbus


1788-CN2FFR – ControlNet to FOUNDATION Fieldbus

Features & Benefits


• Redundancy options:
- Redundant linking devices
- Redundant H1 media
- Redundant ControlNet media
- Ethernet/IP Device Level Ring
- Redundant Controllers
• Fully integrated solution
through the PlantPAx™ process
automation system
• No external configuration software
• Intuitive graphical through AOPs
• Convenient web interface
• Add devices while online
• Auto device discovery
and configuration
• Supports 16 devices
on a single segment
• 8 Input & 8 Output PVs
per field device
Combine the Power of PlantPAx with
• Built-in power conditioners and
FOUNDATION Fieldbus Technology
protection provided on two H1
ports supply 500mA each The Rockwell Automation PlantPAx™ process automation system
• DTM available for provides a single plant-wide control and information platform while
asset management the FOUNDATION Fieldbus standard provides the ability to distribute
the control architecture throughout your facility. Combine these two
powerful technologies to enable integrated, seamless distribution of data
and the execution of process control with devices from multiple sources.

The 1788-EN2FFR and the 1788-CN2FFR provide a fully integrated


and easy to use solution for adding FOUNDATION Fieldbus to any
ControlLogix™ platform. The modules provide a direct link from
EtherNet/IP or ControlNet, to the FOUNDATION Fieldbus H1
device level network.
Product Overview
Field Device Tool / Device Type Manager (FDT / DTM)
Integration into RSLogix5000™ is made seamless by
technology is supported, which allows direct access to
the module’s Add-On-Profile (AOP) which provides an
device configuration and diagnostics via FDT frames such
intuitive graphical environment for the configuration of
as FactoryTalk™ AssetCentre. In addition, the Rockwell FDT
the field device network and all field devices. The AOP
Thin Frame (read only) can be launched from a Human
captures all Process Variables (PVs) in Engineering Units
Machine Interface (HMI) or RSLogix5000 (via AOP),
and provides PV status data and extended device
providing operators and technicians a graphical view
diagnostics. Devices can also be quickly configured
of each field device’s status and extended diagnostics.
using the auto configure tool.
To assist with troubleshooting, a 128 x 128 pixel display
provides access to linking device status including network
voltages and currents, internal temperature, as well as
communication quality to each device, and the status
of each device. A built-in webserver also provides
remote access to network and field device data.

The 1788- EN2FFR and 1788-CN2FFR support as many


as16 field devices on a single H1 segment. The linking
devices have full FOUNDATION Fieldbus Host capability
including Link Active Scheduler (LAS) capability.
A predefined data structure for each field device provides
eight input Process Variables (PVs), eight output PVs,
and eight PVs for inter device communication for full
distributed control.

Built-in power conditioners and protection are provided,


helping to minimize installation space requirements.
The H1 segment is divided between two physical ports
with individual protection and a supply of 500mA per
port. These panel or DIN rail mountable devices also
support built-in configurable line termination.

Multiple levels of device and media redundancy are


supported including: ring, split, and redundant trunk.
Likewise, take advantage of redundant EtherNet/IP DLR
and ControlNet media, and duplicate linking device
options for H1 interface redundancy. Redundant H1
topologies are achieved with the use of 1788-FBJB4R
fieldbus junction boxes.

Rockwell Automation is an official ENERGY STAR® Industrial Service and Product Provider. It has proven it provides energy efficiency services and/or products to commercial buildings and industrial manufacturing plants
in the United States by collaborating with an ENERGY STAR Industrial Partner to submit a teaming profile that outlines the scope and resulting savings from energy efficiency-driven projects.
For more information, visit ENERGY STAR for Industry at www.energystar.gov/index.cfm?c=industry.bus_industry

AssetCentre, ControlLogix, FactoryTalk, Hiprom, PlantPAx, and RSLogix are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication1788-PP004B-EN-P – November 2012 Copyright © 2012 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
Supersedes Publication 1788-PP004A-EN-P – April 2012

You might also like