Meter Run Assembly Integral Flow Orifice Assembly is used when Differential Pressure Transmitier has to be directly mounted on the office assembly. This eliminates cost of installation of Differential Pressure Transmitter with impulse piping up to the orifice ‘assembly. The transmitter is mounted on the orifice ‘assembly through @ 3/5 Valve H-type manifold Avoilable with line sizes of 2" & below. However due to process temperature limits of the transmitter, this assembly cannot be used for process lemperatures above 120 Degrees Centigrade. The assembly consists of o orifice plate between two integral blocks having corner tops. Generally meter run pipe is recommended with upstream length of 750mm and downstream length of 250mm. The pipes are welded tothe blocks with end flanges. Integral Orifice Assembly, Manifold valve, DP transmitter & end flanges ‘ww general llowproducscom Integral Meter Run Assembly Advantages of using Integral Meter run assembly: ® Use of an integral orifice flow meter will eliminate the thre measurement inaccuracies recorded in small orifice line installations. '§ The Integral Orifice honed body reduces ID uncertainty '= By inserting precision bored upstream and downstream sections of pipe, the velocity profile distorlion due to pipe roughness is reduced = The self-centering design of the Integral Orifice Plate eliminates plate misalignment, Improves reliability and maintenance costs, The integral orifice flow meter eliminates impulse lines, reducing leak points by over 50% and decrease start-up fime due to the flexibility of numerous process connection options. The direct mount design minimizes line plugging by eliminating long lines, small-bore ports, ond crevices while providing consistently reliable installations. Accuracy upto +0. 5% of volumetric flow rote 1 Integral manifold head allows direct mounting of DP transmitters 18 Ideal fluid types: liquid, gas, and steam DP ransiter, —— Mend Ve. ————" nl Fenge ———s Flenge ion — fre Flonge Integral Orifice Assembly with flange union, manifold valve, jer & end flanges 2 ‘wonegenersllowproduch com Ordering Guide Integral Meter Run Assembly size seca se nssat vevor « « is 5 coy i Hc sauessen 5 ace Mee SAMESSGH 10 aver SMENSSG 40 ia asin SAME NSSCH 60 a mans SAME NSSCH 160 wa, Wer UBuTON san ate eae sanirow vawve wa. ssaigats. wa ssioy 0K, en aued sma oe eo Nor ReouReD PIPE MATERIAL ower ANGE wna secured wee tense timo arua rr Talgata sry oR {nT BODY MATERIAL ws AsmnAles casxer wi BW 3I6L Wi RWSL Sy Smo ron om sma oR Note: 1. Uso the ond flonge details os described in orifice ordering information. 2. Other than above information customer hos fo provide process data as on page no. 32 3. I manifold valve is required then please provide detail specifications for the some. ‘ww general llowproducscom a

You might also like