Example 16-5. Second-Order MFB Band-Pass Filter With F 1 KHZ

This document discusses the design of second-order and fourth-order band-pass filters. It provides the equations to calculate component values for a second-order band-pass filter with given parameters. It then explains that fourth-order band-pass filters can provide a flatter gain response near the mid-frequency and sharper cutoff slopes. The transfer function for a fourth-order band-pass filter is derived by applying a transformation to a second-order low-pass filter function.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views1 page

Example 16-5. Second-Order MFB Band-Pass Filter With F 1 KHZ

This document discusses the design of second-order and fourth-order band-pass filters. It provides the equations to calculate component values for a second-order band-pass filter with given parameters. It then explains that fourth-order band-pass filters can provide a flatter gain response near the mid-frequency and sharper cutoff slopes. The transfer function for a fourth-order band-pass filter is derived by applying a transformation to a second-order low-pass filter function.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

out affecting bandwidth, B, or gain, Am.

For low values of Q, the filter can work without R3,


however, Q then depends on Am via:

* A m + 2Q 2

Example 16–5. Second-Order MFB Band-Pass Filter with fm = 1 kHz


To design a second-order MFB band-pass filter with a mid frequency of fm = 1 kHz, a quali-
ty factor of Q = 10, and a gain of Am = –2, assume a capacitor value of C = 100 nF, and
solve the previous equations for R1 through R3 in the following sequence:

R2 + Q + 10 + 31.8 kW
pf mC p·1 kHz·100 nF
R2
R1 + + 31.8 kW + 7.96 kW
* 2A m 4
* A mR 1
R3 + + 2·7.96 kW + 80.4 W
2Q 2 ) A m 200 * 2

16.5.2 Fourth-Order Band-Pass Filter (Staggered Tuning)


Figure 16–32 shows that the frequency response of second-order band-pass filters gets
steeper with rising Q. However, there are band-pass applications that require a flat gain
response close to the mid frequency as well as a sharp passband-to-stopband transition.
These tasks can be accomplished by higher-order band-pass filters.
Of particular interest is the application of the low-pass to band-pass transformation onto
a second-order low-pass filter, since it leads to a fourth-order band-pass filter.
Replacing the S term in Equation 16–2 with Equation 16–7 gives the general transfer func-
tion of a fourth-order band-pass:
2
s 2·A 0(DW)
b1
A(s) + (16–11)
1)
a1
b1
DW·s ƪ
) 2)
(DW)
b1
2
ƫ ·s 2 )
a1
b1
DW·s 3 ) s4

Similar to the low-pass filters, the fourth-order transfer function is split into two second-or-
der band-pass terms. Further mathematical modifications yield:
A mi A mi s
Qi
·as Qi a
·
A(s) + · (16–12)
ƪ1 ) as
Q1
) (as) ƫ ƪ1 )
2 1 ǒsǓ
Qi a
) ƫ
ǒas Ǔ 2

Equation 16–12 represents the connection of two second-order band-pass filters in se-
ries, where

You might also like